HomeMy WebLinkAboutBLOWER DOOR TESTl 7t3- 0�0 Date: a Contractor: _ Planning & Development Services ' Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 REcsveo p .10 pe�R�lcNn9 � coUn�en` St. LU BLOWER DOOR TEST FORM SCANNED House Infiltration Test Certification BY Prescriptive and Performance Method St. Lucie County Permit#• Job Address: Construction: ( ,i New Construction —Complete (') Existing —After Addition House Infiltrati Test Results SLC Climate Zone 2� CFM (50) _ O` Test Date: r Volume = i .0 ' ) ACH (50) = CFM (50) x 60 / Volume = �'� Mechanical Ventilation required less than 5 ACH Passing results must be & ACH (50) or less (t�'YPass ( ) Fail . FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through B. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 499.105 (3)(f), (g) or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC,-Residential------- -- - -- — ------ — - Where the air Infiiltration rate of a dwelling unit is less than !.air -changes per hour when tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unit shall be provided with whole -house mechanical ventilation in"accordance with Section M3507.3. Testing Corrioanv n.CrN�p: t Company Namq: .1�LTj(> �� s Address: I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. ' Signature: Printed Name: "1 'Yav � i14�4 License/Certification #- 1 Planning& Development Services t• - Building & Code Regulation Division 2300 Virginia Ave, Ron 201 - -� Fort Pierce, FL 34982 .. - Phone:77Z-462-2165 Fax:772-462-6443 - SCANNED BLOWER DOOR TEST FORM BY �. House Infiltration Test Certification St. Lucie County Prescriptive and Performance Method Date:. ��1-'(l i -I Permit #: i 903 -0113 Contractor: A i Job Address: - - i V l : 1 f -7 Ua f r Construction: ( )New Construction —Complete ( )Existing —After Addition _ House Infiltration est esults SLC Climate Zone CFM (50) =-�; Test Date: viw /d 9 Volume= 1Z091 ACH (50) = CFM (50) x 60 / Volume = 3, Z Mechanical Ventilation required less than 5 ACH Passing results must he & ACH (50) or less (Pass ( ) Fail FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour In Olmate Zone 1, 2 and 3 air changes per hour in Climate Zones 3 through B. Testing shall be conducted with a blower door at a pressure of 0.2 inches w, g. (50 Pascals). Testing shall be conducted by either individuals as defined In Section 553.993(5) or (7), Florida Statutes or Individuals licensed asset forth in Section 489.105 (3)(f), (g) or (I) or an approved third parry. A written report of the results of the test shall be signed by the party conducting the test and provided to the code r i. Testing shall be performed at anytime after. creation of all penetrations of the building thermal envelope. FBC, Residential Where the air Infiltration rate of a dwelling unit is less than 5 air changes per hour when tested with a blower door at a pressure of 0.21nch w. c. (50 Pa) In accordance with Section R402.4.1.2 of the Florida Building Cade, Energy Conservation ->je the dwelling unit shall be provided with whole -house mechanical ventilation In accordance with Section M1507.3. Testing company / Company Name: /S /yl•,F7„ Address: 77�- u I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance wi h Section R402.4.1.2 Climate Zone 2. Signature: Printed Name: License/Certification t( TH IS ACKNOWLEDGES THAT HAS MET THE STANDARD REQUIRED BY RESNET, AS A CERTIFIED HOME ENERGY RATER AND RESNET QUALITY ASSURANCE DESIGNEE RTIN # 6821414 Ht + ^RESIDENTIAL ENERGY,SERVICES NETWORK- .: *10 1 Date: 113 Contractor: Job Address: Construction: Planning & Development Services ' Building & Code Regulation Division 2300 Virginia Ave, Rm 201 Fort Pierce, FL 34982 Phone:772-462-2165 Fax:772-462-6443 BLOWER DOOR TEST FORM House Infiltration Test Certification Prescriptive and Performance Method .f RECEMO SEP 1 fi IN Permitting oepartmen� St. Lucie Coo^h' SCANNED BY Permit#: 119(2,3 St. Lucie County Construction — Complete ( • ) Existing —After Addition House Infiltrati° a Results CFM (50) = O Volume = : I �% ACH (50) = CFM (50) x 60 / Volume Passing results must be & ACH (50) or less SLC Climate Zone 2 Test Date: q I Iai� a �I Mechanical Ventilation required less than 5ACH N-Ylra7ss ( )Fall . FBC, Energy The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air changes per hour in Climate Zone 1, 2 and 3 air changes per hour in Climate Zones 3.through 8. Testing shall be conducted with a blower door at a pressure of 0.2 inches w. g. (50 Pascals). Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statutes or individuals licensed as set forth in Section 489.105 (3)(f), (g) or (1) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope. FBC,-Residential------------'----= ---- - ----- - - -- --- ----- Where the air infiltration rate of a dwelling unit is less than 5 air -changes per hourwhen tested with a blower door at a pressure of 0.2 inch w. c. (50 Pa) in accordance with Section R402.4.1.2 of the Florida Building Code, Energy Conservation the dwelling unitshall be provided with whole -house mechanical ventilation in•accordance with Section M1507.3. Testing Corrioanv Company Namg: Address: ;i--1U wneitC_�)Ow 1 �`1.�oa�, %(-• U I hereby certify that the above House Infiltration results demonstrate compliance with FBC Energy Conservation requirements in accordance with Section R402.4.1.2 Climate Zone 2. ' Signature: Printed Name: 6*LvNAe✓ Qi V 0yG License/Certification #: Et-Dc� Certificate of Achievement THIS ACKNOWLEDGES THAT Alexander Rivera HAS MET THE STANDARD REQUIRED BY RESNET, AS A CERTIFIED RATING FIELD INSPECTOR RFI # EL.A7EX Certification Date: June 7, 2019 Certification Expires: June 7, 2022 Tim Smith, RESNET Quality Assurance Designee 15 leightyears RESNET QA Provider # (1998-199)