HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FRL FLORIDA ENERGY EFFICIENCY CODE FCRI a S RUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: FYC-Howland-Proverb
Builder Name: Synergy Homes, LLC
Street: Palmetto or
Permit Office:
City, State, Zip: FortPierce,-FL , 34982
Permit Number:
Owner: Synergy Homes, LLC
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(2103.4 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=6.0 1846.80 ft2
b. Frame - Wood, Adjacent
R=13.0 256.58 ft2
3. Number of units, if multiple family 1
c. NIA
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ftz
10. Ceiling Types (1869.0 sgft.)
Insulation Area
5. Is this a worst case? No
a. Roof Deck (Unvented)
R=20.0 1869.00 ft2
6. Conditioned floor area above grade (ft') 1869.26000976
b. NIA
R= ft2
Conditioned floor area below grade (ftz) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(310.0 sgft.) Description Area
a. Sup: Whole House, Ret: Whole House,
AH: Whol 6 373.85
a. U-Factor: Dbl, U=0.34 310.00 ft2
SHGC: SHGC=0.23
b. U-Factor: NIA ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
34.8 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating syste - R9CETVEDkBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip I leat
31. COP:1.00
SHGC:
' Area Weighted Average Overhang Depth: 7.342 ft.
APR 0 8 2019
Area Weighted Average SHGC: 0.230
14. Hot water systE ms
a. Electric gT, Lucie County,
Permittir@a : 50 gallons
B. Floor Types (1869.0 sgft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 1869.00 112
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.166 Total Proposed Modified Loads: 65.39
PASS
Total Baseline
Loads: 67.67
/1�7�7
1 hereby certify that the plans and specifications covered by
Review of the plans and
4THlll STgT
this calculation are in compliance with the Florida Energy
specifications covered by this
10 •.' _ ;
Code.
calculation indicates compliance
;FOB
with the Florida Energy Code.�O
PREPARED BY: K� �
Before construction is completed
DATE: 10/29/2018
this building will be inspected for
compliance with Section 553.908
* f k3 Q
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
COD
with the Florida Ene Cody.
WT; CRC
OWNER/A EJT:
BUILDING OFFICIAL:
DATE: q'f lq
DATE:
Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed In accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
10/30/2018 9:44 AM EnergyGauge® USA Section R405.4.1 Compliant Software Pagel of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
- Title:
Building Type:
rOwner Name:
' # of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
FYC-Howland-Proverb
User
Synergy Homes, LLC
1
Synergy Homes, LLD
Single-family
New (From Plans)
Modified Winston model
Bedrooms: 3
Conditioned Area: 1869
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: Palmetto Dr
County: St. Lucie _
City, State, Zip: Fort Pierce ,
FL, 34982
CLIMATE
J Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1869.260 18091.5
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled Heated
1
Whole House
1869.26 18091.5 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio
Whole House 218 ft 0
1869 ft2
---- 0.35 0 0.65
ROOF
/
V #
Roof Gable Roof
Type Materials Area Area Color
Solar
Absor.
SA Emitt Emitt Deck Pitch
Tested Tested Insul. (deg)
1
Hip Composition shingles 2090 ft2 0 ft2 Medium
0.85
No 0.9 No 20 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Unvented 0 1869 ft2
N N
CEILING
#
. Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Unvenled)
Whole House 0 Blown
1869 ft2 0.11 Wood
10/30/2018 9:44 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity
Width Height
Sheathing Framing
Solar Below
Space
1
W
Exterior
Concrete Block - Int InsWhole House
6
15.33
0 9.33 0
143.0 ft2
0
0
0.8
0
2
S
Exterior
Concrete Block - Int InsWhole House
6
16
0 9.33 0
149.3 112
0
0
0.8
0
3
S
Exterior
Concrete Block - Int InsiNhole House
6
9
0 9.33 0
84.0 112
0
0
0.8
0
4
E
Exterior
Concrete Block - Int InsWhole House
6
13
0 9.33 0
721.3 ft2
0
0
0.8
0
-5
S
Exterior
Concrete Block - Int InsiNhole House
6
14
0 9.33 0
130.6 112
0
0
0.8
0
6
N
Exterior
Concrete Block - Int Ins1#hole House
6
14
0 9.33 0
130.6 112
0
0
0.8
0
7
S
Exterior
Concrete Block - Int InsWhole House
6
3
0 10 0
30.0 112
0
0
0.8
0
_ 8
E
Exterior
Concrete Block - Int InsVVhole House
6
13
0 12.33 0
160.3 ft2
0
0
0.8
0
9
W
Exterior
Concrete Block - Int InsUYhole House
6
13
0 12 0
156.0 ft2
0
0
0.8
0
10
W
Exterior
Concrete Block - Int lnsWhole House
6
12
0 9.33 0
112.0 ft2
0
0
0.8
0
11
S
Exterior
Concrete. Block - Int InsWhole House
6
12
0 9.33 0
112.0 ft2
0
0
0.8
0
12
W
Exterior
Concrete Block - Int InsWhole House
6
15
0 9.33 0
139.9 ft2
0
0
0.8
0
13
N
Exterior
Concrete Block - Int InsWhole House
6
12
0 9.33 0
112.0 ft2
0
0
0.8
0
_ 14
N
Exterior
Concrete Block - Int Insiffhole House
6
13
0 9.33 0
121.3 ftz
0
0
0.8
0
_ 15
N
Exterior
Concrete Block - Int InsWhole House
6
8.5
0 9.33 0
79.3 ft2
0
0
0.8
0
16
E
Garage
Frame - Wood Whole House
13
12
0 9.33 0
112.0 ft2
0
0.23
0.8
0
17
E
Exterior
Concrete Block - Int Insiffhole House
6
7
0 9.33 0
65.3 ft2
0
0
0.8
0
18
E
Garage
Frame - Wood Whole House
13
8
0 9.33 0
74.6 ft2
0
0.23
0.8
0
19
N
Garage
Frame - Wood Whole House
13
2
0 9.33 0
18.7 ft2
0
0.23
0.8
0
20
E
Garage
Frame - Wood Whole House
13
3.5
0 9.33 0
32.7 ft2
0
0.23
0.8
0
21
N
Garage
Frame - Wood Whole House
13
2
0 9.33 0
18.7 ft2
0
0.23
0.8
0
DOORS
#
Omt
Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
E
Insulated Whole House
None .29
3
8
24 ft2
2
E
Insulated Whole House
None .29
3
8
24 ft2
3
E
Insulated Whole House
None .29
2.7
8
21.4 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp Area
Depth
Separation
Int Shade
Screening
1
W 1
Vinyl Low-E Double Yes
0.34
0.23
N 48.0 ft2
10 It 0 in
1 It 0 in
Drapes/blinds
None
_
2
E 4
Vinyl Low-E Double Yes
0.34
0.23
N 20.0 112
2 It 0 in
2 It 0 in
None
None
3
S 7
Vinyl Low-E Double Yes
0.34
0.23
N 4.0 ft2
2 ft 0 in
2 It 0 in
None
None
4
E 8
Vinyl Low-E Double Yes
0.34
0.23
N 15.0 112
10 It 0 in
4 It 0 in
Drapes/blinds
Exterior 5
5
W 9
Vinyl Low-E Double Yes
0.34
0.23
N 96.0 ft2
10 It 0 in
4 ft 0 in
Drapes/blinds
None
_
6
W 9
Vinyl Low-E Double Yes
0.34
0.23
N 33.0 ft2
10 it 0 in
1 It 0 in
None
None
_
7
W 10
Vinyl Low-E Double Yes
0.34
0.23
N 30.0 ft2
2 ft 0 in
1 It 0 in
Drapes/blinds
Exterior 5
8
S 11
Vinyl Low-E Double Yes
0.34
0.23
N 15.0 ft2
10 it 0 in
1 ft 0 in
Drapes/blinds
Exterior 5
9
W 12
Vinyl Low-E Double Yes
0.34
0.23
N 15.0 ft2
2 ft 0 in
2 It 0 In
Drapes/blinds
Exterior 5
10
N 14
Vinyl Low-E Double Yes
0.34
0.23
N 15.0 ft2
2 ft 0 in
2 It 0 in
None
Exterior 5
11
N 15
Vinyl Low-E Double Yes
0.34
0.23
N 4.0 ft2
2 ft 0 in
2 It 0 in
None
None
10/30/2018 9:44 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WINDOWS
Orientation shown is the entered, Proposed orientation.
- /
V #
Wall
Ornt ID Frame Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
12
E 17 Vinyl Low-E Double Yes
0.34 0.23 N 15.0 ft2 2 ft 0 in 2 ft 0 in Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
454.9689 ft2 454.9689 ft2
65.33 it 9.33 ft 0
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000307
1507.6 82.77 155.65 .2359 5
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity Block
Ducts
1
Electric Strip Heat/
None
COPA 31 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
- 1
Central Unit/
None
SEER: 16 34.8 kBtu/hr 1044 cfm 0.77 1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric None
Garage
0.92 50 gal 60 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2 '
DUCTS
V #
---- Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT ON RLF
HVAC#
Heat Cool
1
Whole House 6 373.85
Whole House 93.463 Default Leakage Whole Hou (Default) (Default)
1 1
10/30/2018 9:44 AM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
TEMPERATURES
Y
•'Programable ThermostaCoollng
Ceiling Fans:
Jant:
rr Mar
Apr
a((f
rI Jul
rI
lxi
rr Seprf
Oct
[`x]� rr
VentiDec
Jan
Feb
Mar
�X�
Apr
May
jII
IXI Jun
Jul
iII
Aug
Sep
Oct
Nov
Dec
ng
[
[
[
[X�
[)�
lxl [
Thermostat Schedule:
HERS 2006 Reference
Hours
_Schedule.Type. _
_
1 -
2.
3
4
-5- -
6 -
7
8-
9
10
- 11. -
12.
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM
Fan Wafts HRV
Heating System
Run Time Cooling System
Runtime Vent
75
0
0
0
1 - Electric Strip Heat
%
1 - Central Unit
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ft'
0 ft
0.3
Whole House
Name: .
Rating Compant: .
Signature:
Date:
10/30/2018 9:44 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0
c) AHU location Whole House/Whole House
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1869
d) Room unit/PTAC EER
e) Other
16.0
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.340
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.230
14. Heating system: Capacity
31.0
c) Area
7c.
310.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.92
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
6.0
0 Heat recovery unit HeatRee/o
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1081.
13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
0.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
BuilderSignatureL�XL__ Date:
Address of New Home: Palmetto Dr City/FL Zip: Fort Pierce, FL 34982
10/30/2018 9:44:51 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction:
Permit #:
Jobpnformation
Builder: Synergy Homes, LLC Community: Lot: NA
Address: Palmetto Dr
City: Fort Pierce State: FL Zip: 34982
Air Leakage Test Results Passing results must meet either the Performance, Prescriptive, or ERI Method
O PRIES CRIPTIVE'METHOD-The .. building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7:air
- changes per hour at apressure of 0.2 inch w.g. (50. Pascals) in Climate Zones 1 and 2..
O, PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the,selected ACH(50) value, as shown on Form R405-2017 (Performance) orR406-2017 (ERI), section. labeled as infiltration, sub -section ACH50.
ACH(50). specified on Form R405-2017-Energy Calc (Performance). or R406-2017 (ERI); 5.000
x 60 _ 18091 — Method for calculating building volume:
CFM(50) Building Volume ACH(50)
Q Retrieved from architectural plans
❑ PASS • Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation Q Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals).
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and Flue dampers shall be closed, but not sealed beyond Intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
10/30/2018 9:45:08 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1