Loading...
HomeMy WebLinkAboutHAZARD INFORMATION3/13/2019 CiTc Hazards by Location Search Information Address: 5117 Palmetto Dr, Fort Pierce, FL 34982, USA Coordinates: 27.3711478,-80.31310259999998 Elevation: 18 ft ` Timestamp: 2019-03-13T20:27:59.426Z ,izard Type: Wind ASCE 7-16 MRI 10-Year MRI 25-Year MRI 50-Year 107 mph 120 mph MRI 100-Year A 132 mph ru are in a wind-borne debris region if you are also thin 1 mile of the coastal mean high water line. Risk Category I Risk Category II You are in a wind-borne debris region. ASCE 7-10 MRI 10-Year MRI 25-Year MRI 50-Year ATC Hazards by Location rRd 107 mph 120 mph MRI 100-Year A 132 mph You are in a wind-borne debris region if you are also within 1 mile of the coastal mean high water line. 148 mph Risk Category I 148 mph White City ASCE •7-05 left 9 Inft.i"M Diva, Map , Report a map error ASCE 7-05 Wind Speed You are in a wind-borne debris region. SCANNED BY Risk Category III A 172 mph Risk Category III -IV A 172 mph St. Lucie County If the structure under consideration is a healthcare facility If the structure under consideration is a healthcare and you are also within 1 mile of the coastal mean high facility and you are also within 1 mile of the coastal water line, you are in a wind-borne debris region. If other mean high water line, you are in a wind-borne debris occupancy, use the Risk Category II basic wind speed region. If other occupancy, use the Risk Category II contours to determine if you are in a wind-borne debris. basic wind speed contours to determine if you are in region. a wind-borne debris region. https://hazards.atcouncii.org/#/wind?lat=27.3711478&ing=-80.31310259999998&address=5117%2OPaimefto%2ODr%2C%20 Fort%20P!erce%2C%20 FL%2034982%2C%2OUSA A 160 mph Risk Category II A 160 mph You are in a wind-borne debris region. ® 141 mph 1/2 311312019 ATC Hazards by Location Risk Category IV ® 182 mph You are in a wind-borne debris region. The results indicated here DO NOT reflect any state orlocal amendments to the values or any delineation lines made during the building code adoption process. Users should confirm any output obtained from this tool with the local Authority Having Jurisdiction before proceeding with design. Disclaimer Hazard loads are interpolated from data provided in ASCE 7 and rounded up to the nearest whole integer. Per ASCE 7, islands and coastal areas outside the last contour should use the last wind speed contour of the coastal area — in some cases, this website will extrapolate past the last wind speed contour and therefore, provide a wind speed that is slightly higher. NOTE: For queries near wind-borne debris region boundaries, the resulting determination is sensitive to rounding which may affect whether or not it is considered to be within a wind-borne debris region. �)untainous terrain, gorges, ocean promontories, and special wind regions shall be examined for unusual wind conditions. While the information presented on this website is believed to be correct, ATC and its sponsors and contributors assume no responsibility or liability for its accuracy. The material presented in the report should not be used or relied upon for any specific application without competent examination and verification of its accuracy, suitability and applicability by engineers or other licensed professionals. ATC does not intend that the use of this information replace the sound judgment of such competent professionals, having experience and knowledge in the field of practice, nor to substitute for the standard of care required of such professionals in interpreting and applying the results of the report provided by this website. Users of the information from this website assume all liability arising from such use. Use of the output of this website does not imply approval by the governing building code bodies responsible for building code approval and interpretation for the building site described by latitude/longitude location in the report. hftps://hazards.atcouncii.org/#/wind?lat=27.3711478&ing=-80.31310259999998&address=5117%20Paimefto%20Dr%2C%20Fort%20Pierce%2C%20FL%2034982%2C%20USA 212