HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY: q
DATE FILED: I
REVISION FEE: 71ti_
PERMIT # 1903-0189
RECEIPT # I O
PLANNING & DEVELOPMENT SERVICESLAeP
"""`"
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE R 2 2 2019
FORT PIERCE, FL 34982-5652
(772) 462-1553 FAX (772) 462-1578 County, Per
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
L LOCATION/SrrE SCANNED
ADDRESS: 5312 Oakland Lake Cir. (lot 20) BY
uae County
2. DETAILED DESCRIPTION OF PROJECT
REVISIONS:
Revision to Product Approval Chart. Changed to PGT Windows.
3.
4.
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #: CRC057817 ��UNTY CERT. #:
BUSINESS NAME:TWRY
ADD_
__
NAM50 CENT
ADDRESS: 1144,
CITY: STATE: ZIP:
PHONE (DAYTIME): FAX: 56-1--720-1341
OWNER/BUILDER INFORMATION:
NAME: NVR, INC. dba RYAN HOMES
ADDRESS:
CITY:
PHONE:
I.
1
5. ARCHITECT/ENGINEER. INFORMATION:
NAME: AB DESIGN GROUP INC.
ADDRESS: T447
CITY: LOT
PHONE (DAYTEVIE):
Revised 07/22/2014
407-774-6078
STATE:
ZIP: S2/:)U
FAX: 407-774-407R
9D
g
a RE"ISIONW
N a
NVR -Business Use Only
W CV
Planning &Development Services Department c.i Iz U
Building &Regulations Division U.J 0— w
111111 /y Product Review Affidavit ¢ J FILE COPY
Building Permit # I I o 3- o/ 3 q Owners Name: NVR Inc DBA Ryan Homes Applicant: NVR Inc DBA Ryan Homes
Product
Opening
Design
Pressures
Product
Rated
Design
Pressure
Manufacturer
Model If
Product
Approval
Number
Glass Type
Method of Attachment
Windows
+32.37/-42.62
+50.2/-50.2
PGT Industries
SH-200
17-0630.02
non -Impact
# 10 Wood Screw with sufficient length to achieve 1-1/4" embedment. Required anchors: Head (3), Jamb (3)
Mullions
N/A
+/-75
PGT Industries
PGT
17-0630.01
N/A
Use Y." Tapcon with sufficient length to achieve a 1 Y" min. embedment with 2 Y" minimum edge distance
Fixed Glass
+29.65/-38.87
+/-58.9
PGT Industries
PW-220
17-0614.05
non -Impact
# 10 Wood Screwwith sufficient length to achieve 1-1/4"embedment. Required anchors: Head (3), Jamb (3)
Sliding Glass Doors
+28.74/-42.62
+35.3/-89.6
PGT Industries
SGD-2500
18-0207.05
non -impact
3/16"Tapcon with sufficient length to achieve 1-1/4"embedment. Required anchors: Head/Sill (6), Jamb(5)
Swing Type Doors
+30.64/-30.64
+67.01-67.0
Therma Tru
3'0"x8'0"
FL5891.5
N/A
f W Tapcon Y.", Min Embedment 1-1/4", Min Clearance to edge 2", Min Clearance to adjacent anchor 4"; OR ELCO
Tapcon 1/4", Min Embedment 1-1/4", Min Clearance to edge 1", Min Clearance to adjacent anchor 4". Anchor
Spacing Max 18.5" O.0
Garage Doors
+25.91/-31.39
+36/42
Clopay
160 model 73W6
FL 16546.4
N/A
Jamb to block an vertical jamb 1/4" X 11/4" min embedded Tapcon. Max sparing of 71/2" and 1" OD steel washer
required.
Hurricane Protection
N/A
+401-40
Eastern Metal
24ga Steel Panels
FL 11964.2
N/A
1/4"Tapcon Anchors, SG Tapcon or 1/4"X3/4". All points Solid -set Anchors.
Roofing Material
N/A
N/A
Tamko
N/A
FL 18355.1
N/A
Soffits (Panel Walls)
N/A
N/A
Ply Gem
Mastic Soffits
FL 23352.1
N/A
Structural Component
N/A
N/A lHuberEng.
ZIP System
FL 17147.2
N/A
I have reviewed the above components or cladding and I have approved their use In this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions.
Name: James Joseph Cantwell Signature:_ JAMES JOSEPH CANTWELL _,f{fJily
Design Prof: Architect Cert. No. AR0012079 Date: _4/16/2019
d