Loading...
HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY: q DATE FILED: I REVISION FEE: 71ti_ PERMIT # 1903-0189 RECEIPT # I O PLANNING & DEVELOPMENT SERVICESLAeP """`" BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE R 2 2 2019 FORT PIERCE, FL 34982-5652 (772) 462-1553 FAX (772) 462-1578 County, Per APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION L LOCATION/SrrE SCANNED ADDRESS: 5312 Oakland Lake Cir. (lot 20) BY uae County 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: Revision to Product Approval Chart. Changed to PGT Windows. 3. 4. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CRC057817 ��UNTY CERT. #: BUSINESS NAME:TWRY ADD_ __ NAM50 CENT ADDRESS: 1144, CITY: STATE: ZIP: PHONE (DAYTIME): FAX: 56-1--720-1341 OWNER/BUILDER INFORMATION: NAME: NVR, INC. dba RYAN HOMES ADDRESS: CITY: PHONE: I. 1 5. ARCHITECT/ENGINEER. INFORMATION: NAME: AB DESIGN GROUP INC. ADDRESS: T447 CITY: LOT PHONE (DAYTEVIE): Revised 07/22/2014 407-774-6078 STATE: ZIP: S2/:)U FAX: 407-774-407R 9D g a RE"ISIONW N a NVR -Business Use Only W CV Planning &Development Services Department c.i Iz U Building &Regulations Division U.J 0— w 111111 /y Product Review Affidavit ¢ J FILE COPY Building Permit # I I o 3- o/ 3 q Owners Name: NVR Inc DBA Ryan Homes Applicant: NVR Inc DBA Ryan Homes Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model If Product Approval Number Glass Type Method of Attachment Windows +32.37/-42.62 +50.2/-50.2 PGT Industries SH-200 17-0630.02 non -Impact # 10 Wood Screw with sufficient length to achieve 1-1/4" embedment. Required anchors: Head (3), Jamb (3) Mullions N/A +/-75 PGT Industries PGT 17-0630.01 N/A Use Y." Tapcon with sufficient length to achieve a 1 Y" min. embedment with 2 Y" minimum edge distance Fixed Glass +29.65/-38.87 +/-58.9 PGT Industries PW-220 17-0614.05 non -Impact # 10 Wood Screwwith sufficient length to achieve 1-1/4"embedment. Required anchors: Head (3), Jamb (3) Sliding Glass Doors +28.74/-42.62 +35.3/-89.6 PGT Industries SGD-2500 18-0207.05 non -impact 3/16"Tapcon with sufficient length to achieve 1-1/4"embedment. Required anchors: Head/Sill (6), Jamb(5) Swing Type Doors +30.64/-30.64 +67.01-67.0 Therma Tru 3'0"x8'0" FL5891.5 N/A f W Tapcon Y.", Min Embedment 1-1/4", Min Clearance to edge 2", Min Clearance to adjacent anchor 4"; OR ELCO Tapcon 1/4", Min Embedment 1-1/4", Min Clearance to edge 1", Min Clearance to adjacent anchor 4". Anchor Spacing Max 18.5" O.0 Garage Doors +25.91/-31.39 +36/42 Clopay 160 model 73W6 FL 16546.4 N/A Jamb to block an vertical jamb 1/4" X 11/4" min embedded Tapcon. Max sparing of 71/2" and 1" OD steel washer required. Hurricane Protection N/A +401-40 Eastern Metal 24ga Steel Panels FL 11964.2 N/A 1/4"Tapcon Anchors, SG Tapcon or 1/4"X3/4". All points Solid -set Anchors. Roofing Material N/A N/A Tamko N/A FL 18355.1 N/A Soffits (Panel Walls) N/A N/A Ply Gem Mastic Soffits FL 23352.1 N/A Structural Component N/A N/A lHuberEng. ZIP System FL 17147.2 N/A I have reviewed the above components or cladding and I have approved their use In this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: James Joseph Cantwell Signature:_ JAMES JOSEPH CANTWELL _,f{fJily Design Prof: Architect Cert. No. AR0012079 Date: _4/16/2019 d