Loading...
HomeMy WebLinkAboutEVALUATION REPORTEXTERIOR RESEARCH & DESIGN, U.C. Certificate ofAuthorization #9503 TRINITY I ERD SCANNED 353 Christian Street BY Oxford, CT 06478 StLucie County(203) 262-9245 . EVALUATION REPORT TRI-BUILT Materials Group, LLC Evaluation Report A42970.10.12-R2 PO Box70 FL16027-112 Rutherford, NJ 07070 Date of Issuance: 10/23/2012 (800) 516-1485 Revision 2: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 61h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 26-page Appendix. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The haimile seal appearing was authorized by Robert Nieminen, P.E on 09/25/2017. This does notsem wan electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, U.C. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. \ TRININ ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing - Sub -Category: Modified Bitumen Roof Systems Compliance Statement: TRI-BUILT Modified Bitumen Roof Systems, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 61h Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1504.3.1 Wind FM4474 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/39/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 ERD (TST6049) Physical Properties P37590.03.13-3A 03/06/2013 ERD (TST6049) FM 4470/4474 P39680:03.13 03/04/2013 ERD (TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013 ERD (TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD (TST6049) Physical Properties P37590.03.13-5-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-1 07/02/2013 ERD (TST6049) Physical Properties P45940.09.13 09/04/2013 ERD (TST6049) Physical Properties P44370.10.13 10/04/2013 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2DSA9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals (TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 05/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals (TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006 Exterior Research and Design, I.I.C. Evaluation Report A42970.10.12-R2 Cenifimre ofAotharizalon 09503 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL16027-RZ TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 2 of 4 'N"" I RINIIY f ERD i ' TABLE1E-2: WOOD DECKS— NEW CONSTRUCTION, REROOF (TEAR -OFF) OR RECOVER ` - SYSTEM TYPE E:NON-INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOFCOVER -^ System Base Sheet Roof Cover�(Note 15) Mop No. Deck (Note 1) Base Fasteners Attach Base Ply Cap Ply (Psf) Min. 19/32-inch Polyglass Elastobase, Polyglass Elastobase Poly Polyglass G2 Base, CertainTeed OMG Fla[ Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch (Optional) One or SBS-AA, SBS- W-1 plywood at max. Glashase, Firestone MB Base, JM Per ma- Roofgrip #14, Dekfast Hex with Dekfast #14 o.c. in two, equally spaced, staggered more BP -AA or TA, APP-TA -52.5 24-in[h spans ply 28, Tamko Glass Base or GAFGLAS #75 or TruFast MP-3 with TruFast HD center rows APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast #14 or TruFast MP- 12-Inch o.c. In 4-Inch lap and 12-inch One or more SBS- SBS-SA, APP- W-2 plywood at max. Elastobase Poly with poly [op surface 3 with TruFast HD o.c, in two, equally spaced, staggered SA SA, SBS-TA or -52.5` 24-inch spans center rows APP-TA Min. 19/32-Inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-inch o.c. in 4-inch lap and 12-inch (Optional) One or SBS-AA, SBS- W-3 plywood at max. Elastobase Poly Roofgrip #12 o.c. In two, equally spaced, staggered more BP -AA or TA APP TA -60.6 24-inch spans center rows APP-TA Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-Inch o.c. in 4-inch lap and 12-Inch One or more SBS- SBS-SA, APP- W-4 plywood at max. Elastobase Poly with poly top surface Roofgrip #12 o.c. in two, equally spaced, staggered SA SA, SBS-TA or -60.0` 24-inch spans center rows APP-TA TABLEiF: WOOD DECKS- NEW CONSTRUCTION OR REROOF(TEAR-OFF) SYSTEM TYPE Ft NON-1 NSULATED, BONDED ROOF COVER - System Roof Cover (Note 15) MOP No. Deck Primer (psf) Joint Treatment Base Ply Ply Cap Ply W 5 Min. 15/32-inch plywood (Optional) ASTM D41 None SBS-SA (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA -90.0 at max. 24-inch spans APP-TA or APP-TA W-6 Min. 15/32-Inch plywood (Optional) ASTM D41 Plywood joints are covered with 4-Inch wide strips of TriBuilt SA TriBuilt SA SBS Base (Optional) SBS-SA or SBS-SA, APP-SA, SBS-TA 97.5 at max. 24-Inch spans SBS Base, rolled into place to create continuous bond. APP-TA or APP-TA Exterior Research and Design, U.C. d/b/a Trinity I ERD Evaluation Report A42970.30.12-R2 for FL16027-R2 Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nleminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 8 of 26 Q"TRINITYIERD 15. Unless otherwisenoted, refer to the following references for bonded base, ply or cap sheet applications. TABLE1:TRI•BUILTRODF COVERS Reference Layer Material Application BP -AA Base Ply FBC Approved ASTM D4601, Type 11 (Base and Ply sheets, Asphalt -Applied) HA at 20-40 lbs/square Ply FBC Approved ASTM D2178, Type IV or VI SBS-AA Cap Ply TriBuilt SBS Granular HA at 20-40lbs/square (SBS, Asphalt -Applied) SBS-TA Cap Ply ThBullt SBS Granular Torch -Applied (505, Torch -Applied) SBS-SA Base Ply TrlBulIt SA SBS Base (SBS, Self -Adhering) Self -Adhering Cap Ply TnBuilt SA SBS Cap :APP-TA Base Ply or Ply TrlBUIIt APP Smooth (APP, Torch -Applied) Torch -Applied Cap Ply TriBullt APP Smooth, TriBuilt APP Granular APP SA Cap Ply TriBuilt SAAPP Cap Self -Adhering (APP, Self -Adhering) 16. Vapor barrier options for use over structural concrete deck followed by adhered Insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A applies: .VAPOR BARRIER OPTIONS; STRURURAI CONCRETE DECK; ADHERED INSULATION PER TABLE 3A - - Option N Primer Vapor Barrier Insulation Adhesive MDP (psf) Type Attach VB-1. ASTM D41 TriBuilt SA SBS Base Self -Adhering Inta-Stik or CR-20, 12-Inch o.c. -60.0 VB-2. ASTM D41 TriBuilt SA SBS Cap Self -Adhering Insta-Stik, 12-inch o.c. -75.0 VB-3. ASTM D41 TriBuilt SA SBS Cap Self -Adhering Millennium One Step Foamable Adhesive,l2-inch o.c. -157.5 VB-4. ASTM D41 ThBuilt SA SBS Cap Self -Adhering CR-20, 12-Inch o.c. -270.0 VB-5. ASTM D41 TriBuilt SA SBS Base Self -Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20, 12-inch o.c. -290.0 %'^. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements. 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, U.C. d/b/a TrinityI ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization #9503 6'H EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/2512017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26