HomeMy WebLinkAboutENGINEERING LETTER - PAUL WELCHFebruary 25, 2019 Re: Ward Re -Roof 939 Nettles Blvd Jensen Beach, FL PAUL WELCH INC. Mechanical Electrical Civil Engineering 1984 S.W. Biltmore St. Suite#114 Port Saint Lucie, FL 34984 Phone (772) 785 - 9888 E-mail pwelchinc@aol.com SCANNED BY St. Lucie County SCOPE OF WORK: Install new Metal Roof (Extreme Metal Fabricators, LLC "5-V Crimp" FL #17022.1) at above referenced address over new underlayment, and existing plywood sheathing. DESTGN CRYI'ERIA: FBC 2017 ASCE7-10 PROJECT DATA: BUILDING HIEGHT=12'-0" A= 3" MEAN ROOF HIEGHT = <20' ROOF ANGLE = 5:12 SHAPE = PITCHED GABLE ADJUSTMENT FACTOR = 1.00 IMPROTANCE FACTOR = 1.00 WIND VELOCITY V ult = 165WH WIND VELOCITY V esd= 128 MPH EXPOSURE = D ENCLOSURE CLASS = ENCLOSED BUILDING INTERNAL PRESSURE COEFFICIENT = -0.18 ZONE 1 (Field) _ -40.3 ZONE 2 (Perimeter/ Ridge) _ -68.0 ZONE 3 (Corners) _ -99.8 939 Nettles Blvd Jensen Beady FL Paul•Welch Inc. Paul Welch P.E. Reg. No. 29945 ,February 25, 2019 1 of3 Metal roofing to be attached with corrosion resistant Hex -Head wood screws #10 x I %" minimum with weather sealing washers (minimum 3/16" penetration through deck). Fasteners shall be placed through the panel ribs at 12" on center across panel width and spacing along the ribs as follows: ZONE 1 (Field): FASTENER SPACING =16" O.C. ZONE 2 (Perimeter/ Ridge): FASTENER SPACING = 16" O.C. ZONE 3 (Comers): FASTENER SPACING = 8" O.C. NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT.:12 HORZ. Design uplift Pressure for attachment as per above: Product Design Pressure: Zones 1 & 2:-93.5PSF / Zone 3:-101PSF Therefore O.K. UNDERLAYMENT: Undeilayment shall be in accordance with manufacturer's guidelines, FBC 1507.4.5.1, and FBC 15074.5.2. Underlayment shall be Polyglass Polystick TU Plus FL# 5259.1 DECK INSTALLATION: Re -nail all plywood sheathing (15/327 thick minimum) with 8D ring -shank nails at 4" O.C. perimeter and 6" O.C. field for all zones. All work to be in compliance with product approval (FL # 17022.1), manufacturer's specifications, and the Florida Building Code 2017. 939 Nettles Blvd Jensen Beach, FL Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 February 25, 2019 2of3 ROOF ZONE PLAN A=3 , Q1,Q2 ,Q3 = ZONE DESIGNA2YON ('TYPICAL) NOTE: PROVIDE LAP SEALANT FOR ALL ROOF PANEL LAPS FOR ROOF SLOPES UNDER 3 VERT.:12 HORZ. Paul Welch Inc. Paul Welch P.E. Reg. No. 29945 February 25, 2019 939 Nettles Blvd Jensen Beach, FL 3 of 3