HomeMy WebLinkAboutPOOL PLAN - LAYOUT16'-7" 5' 11'-7" 18" RAISED SPA 18" BENCH - 20" BELOW W.L. (6) THERAPY JETS (2) FILTERED INLETS (1) AQ L ASTAR 32CDFL - 32" CHANNEL �� DRAIN (316 GPM ', 3.9 FT/SEC THRUGRATE - SINGLE UNBLOCKABLE OR EQUAL) SPA SIDE AIR SWITCH (1) LED SPA LIGHT - NICHELESS 360 DEGREE SPILLWAY 13 -6w' 2 HP AIR BLOWER 'II � I N NOTE: I 1.5" SCH 40� EXISTING 48" MIN. HIGH FENCE W/ I� SELF LATCHING GATE THAT SWINGS OUT I 2" PVC UMBRELLA AWAY FROM POOL AREA VERIFY EXIST. I SLEEVE FENCE IN COMPLIANCE W/ CHILD SAFETY I CUT FLUSH WITH BARRIER REQUIREMENT'S PER FBC SIXTH SUN SHELF 2 5" H 40 EDITION (2017) I SC 18' I 6 (2) BUBBLERS W/ ' I 15' SUPPLY LINE AND VALVE I 1.5" SCH 40 I SKIMMER "HST � 2•• SCH 40 o C--L���- I (—� i NOTE: PROVIDE WINDOW AND DOOR 10,1611 ALARMS ON ALL OPENINGS THAT LEAD ONTO POOL AREA PER FBC SIXTH EDITION, 2017 i LL POOL/SPA EQUIP. SEE SITE PLAN: BY OTHERS REINFORCED OR PRODUCT APPROVED CONCRETE SLAB(S) (FIELD VERIFY SIZE & LOCATION) -ter U U a 14'-4" IT �— �71 /3" SCH 40 2.5" �CH 40 AQIIASTAR 32CDFL - 32" CHANNEL DRAIN (316 GPM @3.9 FT/SEC THRU GRATE - SINGLE UNBLOCKABLE COMPLIANT W/ ASME/ANSI A 112.19.8 - 2017 OR EQUAL (3) LED LIGHTS - 16'-7" 71 11'-7" 5' 5'-8rr 1.5� H 40 I I I I PERIMETER BONDING fI WIRE O 18"MIN. - 24" MAX. I FROM W.L. (SE'E,DETAIL) i I }-=�--=-- ---= HANDHOLDS REQUIRED @ 48" MAX. SPACING - SEE DETAIL STUB -OUT FOR POOL CLEANER (4) 240 SQ. 1N. MIN. TOP TREAD 1.5"SCIf 40j i --------------------- 2" SCH 40�'. 5' T NOTE: POOL CONTRACTOR TO VERIFY ALL PROPERTY LINE LOCATIONS AND POOL EXIST. PORCH ELEVATION PRIOR TO CONSTRUCTION. POOL LAYOUT AND DIMENSIONS TO BE VERIFIED W/ OWNER PRIOR TO i CONSTRUCTION POOL/SPA LAYOUT & PIPING PLAN SCALE: 1 /4"=1'-0" rr n 6' RE na 13'-6" NOTE: FINAL YARD GRADES TO BE FLUSH WITH EDGE OF POOL DECK (OR POOL WHERE NO DECK IS PROVIDED) AND TO SLOPE AWAY FROM POOL/DECK AT 1':12' MAX. FOR FIRST 6' FROM EDGE. EXIST, RESIDENCE NOTE: THESE PLANS ARE FOR POOL AND SPA STRUCTURES, PLUMBING, EQUIPMENT/ELECTRICAL & DECK ONLY. ALL OTHER FEATURES DESIGNED BY OTHERS. FILE COPY REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC SCANNED BY St. Lucie County W M M v y a� C � � o �w ,YYYYYYL LL!/t/t t NP` .. �.. tt% 011 2 u� * LU � 4 •W M = 2 : c H 0. Uti, I Z 'LP 11111,` O � M F-• 1!) N W VY Fx�o � o U 00 Crl 1 00 (1, al U • � Q 3 O �• � U p' 1 A U za C 00 •� N A� M W� O O � ^W h�M DRAWN BY: CLC CHECKED BY: WJC DATE: 3-7-19 SCALE: AS NOTED JOB NUMBER: 19 - 205 SHEET 1 OF 2 SAND SET, INTERLOCKING PAVER DECK BULLNOSE BRICK COPING G Y," PER FOOT 3" �CLEAN FILL COMPACTED TO S w95% MAX. DRY DENSITY �� rSOPEDECK UNDER DECK ONLY u 2-#3 DIA. REBAR w :TOP OF BEAM ��F 5" MARCITE 3 REINFORCING STEEL N3 DIA. REBAR no- 6" IN 12" O.GIE.W.- RADIIUS -. WALLS & FLOOR VARIES TYPICAL WALL SECTION -ice- 1, 14" 1 / PIPE REDUCE TO I'• AND NO N TO DECK (TIRO SLEEV LED L GIIT II INSTALLED INSIDE LED LIGHT DETAIL 6" 18" MIT(-24" MAX. (ENTIRE PIRIMETER) W.L. #8 SOLID BARE COPPER BOND ' - - WIRE W/APM CLAMPS .•. k } (ONE ON EACH SIDE OF POOL-4TOTAL) (1) #8 SOLID BARE COPPER WIRE BONDED TO POOL STEEL AS SHOWN NOTE: BONDING WIRE REQUIRED AT PERIMETER OF POOL EQWPOTENTTAL BONDING DETAIL PER FLORIDA BUILDING CODI ADAPTATION OF N.E.C. 2014 SEC. •0.26 6' #3 DIA. REBAR @ 6" O.C.E.W. 10.5" IN SUN SHELF AREA V x' 4"-6" BELOW SUB -GRADE z_ � N VACUUM FITTING W/ SELF -CLOSING SAFETY COVER (HAY W AR D MODEL N400 OR EQUAL) VACUUM LINE DETAIL CLEAN i COMPACTED SOIL SUN SHELF/BENCH SECTION SCALE: 3/8" = F-0" 6"6" 8" I, I, I, I> 181, C 20vr 6 k � La6 #3 DIA. REBAR `- @ 12" O.C.E.W. CLEAN COMPACTED #3 DIA. REBAR SOIL @ 6" O.C.E.W. IN SPA FLOOR #3 DIA. REBAR @ 6" O.C.E.W. 121 3' 03 DIA. REBAR @ 12" O.C.E.W. SPA/TROUGH SECTION SCALE: 3/8" = 1'-0" 8" 6"6ff HANDHOLD SHALL BE ACCESSIBLE WITHIN 4 FEET NOT TO EXCEED 8 FEET AT ANY TWO POINTS ALONG THE INSIDE OF THE POOL PERIMETER WHERE THE WATER DEPTH EXCEEDS 4 FEET HANDHOLD DETAIL in 181, 61, 6" 5' 18"_ 18"_ 18" IN 4" SKIMMER COVERW' ADJUSTABLE COLLAR I Nr WRAP (2) #3 DIA. AROUND SKIMMER, TIED TO POOL STEEL I LEAF BASKET 7- TO POOL PUMP 25 GPM MIN. FLOW SHIMMER DETAIL 37'-6" - 22' 11f 3'-611 5'-6" 1' SLOPE J POOL SECTION TYPE 'O' POOL 4'-6" POOL SYSTEM FLOW RATE: 150 GPM (MAXIMUM FLOW FROM PUMP CURVE) REC. PUMP = 2.7 HP JANDY E-PUMP - JEP2.OSVRS VARIABLE SPEED -LOW SPEED = 36 GPM MAX. HIGH SPEED = 150 GPM @ 42 TDH 3" SUCTION PIPE @ 150 GPM = 6.63 FT./SEC. (8 FT./SEC. MAX. - SUCTION LINES) 2.5" BRANCH PIPE @ 75 GPM = 5.13 FT./SEC. (6 FT./SEC. MAX. - SUCTION LINES) 3" PRESSURE PIPE @ 150 GPM = 6.63 FT./SEC. (10 FT./SEC. MAX. - PRESSURE LINES) CARTRIDGE FILTER =150 GPM @ 1 GPM/ SQ. FT. = 150 SQ. FT. MIN. FILTER AREA n EQUIPMENT LAYOUT SCALE: N.T.S. 2 HP AIR BLOWER MOTOR W/ BUILT-IN OVERLOAD SWITCH W/3-#12 THHN CU WITHIN 1/2" MIN. CONDUIT(CONNECT TOP 20 AMP - 2 POLE GFCI HEATER (GAS)-IGNArHON SWITCH BREAKER) 3 - 012 THHN CU WITHIN 1/2" CONDUIT (CONNECT TOP 20 AMP -1 POLE GFCI BREAKER) MANUAL MOTOR STARTER SWITCH POOL PANEL W/ 30 AMP 100%2.7 HP PUMP MOTOR w/ BUILT-IN ( RATED) 2-POLE BREAKER OVERLOAD SWITCH W/3-#10 THHN CU WITHIN 1/2" MIN. CONDUIT (CONNECT TOP 20 AMP-2 POLE GFCI T - &(1) #12 GROUND BREAKER) THHN CU IN 1/2" RPVC TIME CLOCK CONDUIT S.P.S.T. TOGGLE SWITCH - W. P. DISCONNECT (3) LED POOL LIGHTS 12 VOLT TRANSFORMER (GFI NOT REQUIRED) JUNCTION BOX (1) LED SPA LIGHT (CFI NOT REQUIRED) 1. ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR TO VERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION. 2. 3412 THHN CU WITHIN 1/2" MIN. CONDUIT FOR POOL LICHT(S). 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/ #8 SOLID, BARE COPPER. 4. PROVIDE W.P.G.F.1. OUTLET 10' MIN. - 20' MAX. FROM WATER'S EDGE. 5. ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(8). 6, LOAD CALCULATIONS FOR EXISTING SERVICE AND PANEL - BY OTHERS. ELECTRICAL DIAGRAM N.T.S. AQUASTAR 32CDFL-32" 32 - 33/32 CHANNEL DRAIN (316 GPM @ 3.9 FT/SEC THRU GRATE.- HYDROSTATIC RELIEF VALVE SINGLE UNBLOCKABLE PORT OR CAP OFF OR EQUAL a v4 FLOOR FINISH PLASTER MAIN DRAIN SUCTION LINE HYDROSTATIC RELIEF VALVE & TIED TOGETHER AS SHOWN PERFORATED PVC COLLECTION ABOVE - PIPE SIZE PER TUBE, WHERE REQUIRED PLAN MIN. Y, YARD GRAVEL SUMP NOTE: 25.9 SQUARE INCH OPEN AREA, WRAPPED W/ DRAIN FEILD 316 GPM = 3.9 FEET PER SECOND CLOTH (RECOMMENDED) Channel Main Drain Detail SCALE: N.T.S. PUMP FRAME OR FILTER TANK MOUNT OR HEATER ANCHOR POOL PUMP AND ,FILTER PER MFGR'S. N.O.A. / 4" THICK REINFORCED CONCRETE SLAB E.G. MIN. -- FILTER FILTER \oo-\ POOL PUMP, FILTER " AND HEATER ANCHOR POINTS MAY VARY POOL EQUIPMENT ANCHORING DETAIL SEE M FGR. SPECIFICATIONS FOR ADDITIONAL ANCHORING INFORMATION - EQUIPMENT SHAPES MAY VARY REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC FILE COPY LEGEND 1. 2" AIR LINE 2. 3" SPA MAIN DRAIN LINE 3. 2" VACUUM LINE 4. 3" POOL MAIN DRAIN LINE 5. 2" SKIMMER LINE 6. 3" RETURN TO JETS 7. 3" POOL RETURN LINE 8. 3" SPA RETURN LINE 9. 1.5" BUBBLER FEED LINES A. 2 HP AIR BLOWER B. 1.5" TO WASTE OR DISCHARGE TO GROUND C. 2.7 HP REC. PUMP W/ APPROVED HAIR & LINT STRAINER D. CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE E. 400,000 BTU GAS HEATER W/ INTERNAL BY-PASS F. CHLORINE GENERATOR G. INSTALL PERMA-CAST PB-2011 WATER BOND OR APPROVED EQUAL TIED TO PUMP GROUND W/ 48 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA EXPOSED TO WATER) PER MFGR'S SPECS (FIELD VERIFY LOCATION) H. VALVES (TYPICAL) GENERAL NOTES: 1. ALL LIGHTS, LADDERS, HANDRAILS, REINFORCING STEEL SHALL BE GROUNDED PER CODE. 2. POOL TO BE CONSTRUCTED OF CONCRETE/GUNITE WITH A MINIMUM COMPRESSIVE STRENGTH OF 4000 P.S.I. AT 28 DAYS. 3. ALL REINFORCING STEEL SHALL BE INTERMEDIATE GRADE DEFORMED BARS OF NEW BILLET STEEL, CONFORMING TO ASTI I A-615, GRADE 60, STEEL SHALL BE BENT, LAPPED AND PLACED IN ACCORDANCE WITH ACI STANDARDS. 4. GRATE IN MAIN DRAIN SHALL HAVE A TREE AREA OF 4 TIMES THE AREA OF THE SUCTION LINE. 5. STEPS TO HAVE A 10" MINIMUM TREAD AND A 12" MAXIMUM RISER. 6. POOL TO BE FENCED PER LOCAL CODES. 7. GATES TO BE SELF -LATCHING, SELF -CLOSING AND LOCKABLE. 8. DESIGN, CONSTRUCTION AND WORKMANSHIP SHALL BE IN CONFORMITY WITH THE REQUIREMENTS OF ANSI/ NSPI 3; ANSI/ NSPI 4; ANSI/ NSPI 5; ANSI/ NSPI 6; AND ANSI/APSP 7 2013 AND ANSI/APSP.ICC-15 2011, 9. SPAS AND HEATED SWIMMING POOLS SHALT. BE EQUIPPED WITH A COVER DESIGNED TO MINIMIZE HEAT LOSS. EXCEPTIONS: OUTDOOR POOLS DERIVING OVER 70 PERCENT OF THE ENERGY FOR HEATING FROM NON-DEPLETABLE ON -SITE RECOVERED SOURCES COMPUTED OVER AN OPERATING SEASON ARE EXEMPT FROM ]'HIS REQUIREMENT. 10. ALL FEATURES OF THE POOL/SPA SHALL BE INSTALLED IN COMPLIANCE WITH . THE FBC SIXTH EDITION (2017) - RESIDENTIAL -PRIVATE SWIMMING POOL AND LOCAL AMENDMENTS, IF ANY. 11. RESIDENTIAL SWIMMING POOL BARRIER SHALL COMPLY WITH FBC SIXTH EDITION (2017)- RESIDENTIAL CHAPTER 45- PRIVATE SWIMMING POOL. 12. PRESUMPTIVE LOAD- BEARING VALUE OF SOIL -IN ACCORDANCE WITH FBC SIXTH EDITION (2017) SECTION 1806.2 TI IE SOIL BEARING VALUE SHALL BE A MINIMUM OF 550 P.S.F. BASED ON A MAXIMUM OF 1/8" SETTLEMENT. 13. SHOULD ANY MUCK, MART., OR OTHER ORGANIC SOILS BE DISCOVERED ON EXCAVATION, THEY SHOULD BE REMOVED IN THEIR ENTIRETY, ALL CONSTRUCTION SHALL STOP AND THE; ENGINEER OF RECORD SHALL BE CONTACTED TO CONDUCT AN INSPECTION. 14. POOL CONTRACTOR/OWNER BUILDERS TO VERIFY ALL POOL DIMENSIONS, POOL LOCATION AND SETBACKS PRIOR TO CONSTRUCTION. (CONTACT ENGINEER IF ANY DISCREPANCIES OCCUR) 15. POOL PLANS ARE DESIGNED TO MEET THE FBC SIXTH EDITION (2017) - RESIDENTIAL -PRIVATE SWIMMING POOLS. 16. ENTRAPMENT PROTECTION FOR SUCTION OUTLETS SHALL BE INSTALLED IN ACCORDANCE WITH REQUIREMENT'S OF ANSI/APSP 7-2013 AND FBC SIXTH EDITION (2017) - RESIDENTIAL CHAPTER 45. PLUMBING NOTES: 1. ALL PIPING, EQUIPMENT AND MATERIALS USED IN THE PLUMBING SYSTEM OF SWIMMING POOLS THAT ARE BUILT IN. PLACE SHALL CONFORM TO THE FBC SIXTH EDITION (2017), PLUMBING, CHAPTER 45 - PRIVATE SWIMMING POOLS. 2. POOL PIPING SHALL BE DESIGNED SO THE WATER VELOCITY WILL NOT EXCEED 6 FT/SEC ON BRANCH SUCTION LINES, 8 FT/SEC. ON SUCTION LINES AND 10 FT/SEC. PRESSURE LINES. 3. VALVES SHALL BE MADE OF MATERIALS THAT ARE APPROVED IN THE FLORIDA BUILDING CODE, PLUMBING. VALVES LOCATED UNDER CONCRETE SLABS SHALL BE SET IN A PIT HAVING AT LEAST A DIMENSION OF FIVE DIAMETERS WITH A MINIMUM OF AT LEAST 10 INCHES AND FITTED WITH A SUITABLE COVER. ALL VALVES SHALL BE LOCATED WHERE THEY WILL BE READILY ACCESSIBLE FOR MAINTENANCE AND REMOVAL. 4. WHERE CHECK VALVES ARE INSTALLED, THEY SHALL BE OF THE SWING OR VERTICAL CHECK PATTERN. 5. ALL HEATERS SHALL BE EQUIPPED WITH AN APPROVED PERMANENT BY-PASS OR ANTI -SIPHON DEVICE INSTALLED TO PROVIDE A POSITIVE MEANS OF RETAINING WATER IN THE HEATER WHEN THE PUMP IS NOT IN OPERATION. 6. ALL POOL PIPING SHALL BE 1.5" SCH. 40 PVC EXCEPT AS SHOWN AND SHALL BEAR THE H.S.P. SEAL OF APPROVAL. - - "- 7. THIS POOL/SPA IS DESIGNED TO WITHSTAND HYDROSTATIC UPLIFT FORCES WHEN EMPTY, FOR WATER TABLE UP TO3'-0" BELOW POOL/SPA DECK ELEVATION. HOWEVER, DUE TO SEASONAL VARIATIONS IN THE WATER TABLE ELEVATIONS, ALL POOL/SPA SHALL BE FITTED WITH A HYDROSTATIC RELIEF VALVE. 8. WATER SUPPLY AND DISPOSAL SHALL BE ARRANGED SO THERE IS NO CROSS SUCTION WITH A DOMESTIC WATER SUPPLY OF WATER DISPOSAL. 9. UNLESS AN APPROVED TYPE OF FILLING SYSTEM IS INSTALLED, ANY WATER SUPPLY WHICH IN THE JUDGEMENT OF THE: ADMINISTRATIVE AUTHORITY MAY BE USED TO FILL THE POOL IF EQUIPPED WITH BACKFLOW PROTECTION. NO OVER -THE -RIM FILL SPOUT WILL, BE ACCEPTED UNLESS LOCATED UNDER A DIVING BOARD, OR PROPERLY GUARDED. 10. ALL POOL/SPA PIPING SHALL BE INSPECTED AND APPROVED BEFORE COVERING OR CONCEALING. IT SHALL BE TESTED AND PROVED TIGHT TO THE SATISFACTION OF THE ADMINISTRATIVE AUTHORITY, UNDER A STATIC WATER TEST OR AIR PRESSURE TEST OF NOT LESS THAN 35 PSI FOR 15 MINUTES. 11. JOINTS AND CONNECTIONS SHALL BE MADE AS REQUIRED BY THE FLORIDA BUILDING CODE, PLUMBING. 12. ALL WATER HEATING EQUIPMENT SHALL BE INSTALLED WITH FLANGES OR UNION CONNECTION ADJACENT T'O THE HEATER. 13. PURPLE PRIMER REQUIRED ON ALI, PC PIPING PER FBC SIXTH EDITION (2017). 14. GAS PIPING SHALL COMPLY WITH FLORIDA BUILDING CODE FUEL GAS. (SEPARATE PLANS AND PERMIT REQUIRED) 15. SWIMMING POOL/SPA WATER HEATERS SHALL BEAR THE LABEL OF A RECOGNIZED TESTING AGENCY. 16. PROVIDE APPROVED BACKFLOW DEVICE AT WATER METER AND PRESSURE VACUUM BREAKER BACKFLOW DEVICE ON WATER SUPPLY WHEN REQUIRED. POOL/SPA SPECIFICATIONS SIZE: 18'-0" X 37'-6" DEPTH: 3'-6" TO 5'-6" VOLUME: 24,400 GALLONS ELEVATION: DET. ON SITE TURN OVER RATE: 11.3 HR. (a, 36 GPM MAX. - LOW SPEED (TURN OVER RATE: 2.7 HR. *a 150 GPM - HIGH SPEED) DESIGN FLOW RATE: = 24,400 GAL./6 HRS./60 MIN. = 68 G. P.M. TILE: STANDARD THERAPY JETS: 6 IN N SPA POOL FINISH: MARCITE OR EQUAL PIPING: SCH. 40 INLETS: POOL (4) SPA (2) DECK: PAVERS ELECTRIC: BY OTHERS POOL LIGHT: (3) LED - NICHELESS SPA LIGHT: (1) LED - NICHELESS LADDER: NO HANDRAIL: NO PUMP: 2.7 HP JANDY E-PUMP - JEP2.OSVRS A.P.S.P. PUMP CERT.: CURVE A - 35 GPM ,, 1725 RPM FILTER: JANDY CL-580 CARTRIDGE 580 SQ. FT. FILTER AREA HEATER: 400,000 BTU GAS HEATER W/ APPROVED COVER VACUUM LINE: YES POOL AREA: 787 S.F. PERIMETER 127 L.F. SPA AREA: 72 S.F. PERIMETER 36 L,F. AUTO -FILL: NO OVERFLOW: NO CHLORINE GENERATOR: YES POOL CONTROLLER SYSTEM: JANDY RS-4 2 HP AIR BLOWER _ M vz >r O, SIIN eo4/�, (1) h M LL Oco G:J W c) :2: � o it F X:4 ¢ O � U>y: i Z .......... K ,�Illllll H11111 • WNW .4 In PMPI C/Y G In zq�� IT�r-1 .. UooO F, z� ON It) hr 1 rram�• x � 3 O � ��T•'I a U M- A U Q.k • � N' A� M V L Vl Poo rrT,�T, h� DRAWN BY: CLC CHECKED BY: WJC DATE: 3-7-19 SCALE: AS NOTED JOB NUMBER: 19 - 205 SHEET 2 OF 2