HomeMy WebLinkAboutKSM REPORTKSM KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, INC. MARTIN (772) 337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772) 589-0712 PALM BEACH (561) 845-7445 C.A.: 5693 P.E.: 37293 S.I.: 860 MELBOURNE (321) 768-8488 FAX (561) 845-8876 ST. LUCIE 229-9093 SOIL COMPACTION REPORT FAX (772) 589-6469 ASTM D 1557 and ASTM D 2922 DATE TESTED September 7, 2005 SCANNED JOB # : f8Tclm BY „,•- PERMIT # 0504-1666 St. Lucie County P.O. #: Errchello CONTRACTOR Pace 2000 O D JOB LOCATION 94 Aqua Ra Drive Lot 19 SEP 9 2005 Jensen Beach, Florida ITEM TESTED Compacted Foundation Fill -- —�, TEST LOCATION DEPTH *PEN DRY MAX. DRY PERCENT OF SAMPLE READ DENSITY PROCTOR VALUE COMPACTION 1. S.E. 0" - 12" 175 109.8 112.3 97.8 2. S.W. 170 109.0 97.1 3. Center 180 110.1 98.0 4. N.E. 170 109.2 97.2 5. N.W. 175 109.6 97.6 Soil Description: Brown Slightly Clayed Fine Sand With Shell Fragments In Place Moisture: 11.3 Percent Optimum Moisture: 11.6 Percent Max. Dry Density: 112.3 P.C.F. @ Test Locations The Density & Penetrometer Readings Indicate the Degree of Compaction Meets Minimum Required 114.0 -1 1 1 1 1 1 w I I I I I I E113.0— G I I I I I I H •L• — -I — — — — 1 T 112.0 — P I I I I I I .111.0L C I I I I I I F110.0� — — —• — — — • I I I I I I D I I I I I I R I I I I I I Y I I I I I I 108,0 T• • 9 10 11 12 13 14 15 Pen. Readings Taken to Natural Grade. Respectf y Sub ' ed: /:772-3 K�, P.E., 0-730 livlivyTo: • �� St. Lucie County Building Department Moisture - % of Dry Weight