Loading...
HomeMy WebLinkAboutTRUSS PAPERWORK4451 ST. LUCIE BLVD FORT PIERCE, FL 34946 PH: 772-409-1010 FX: 772-409-1015 www.AlTruss.com �� F LOh� lb�i�tQ Fi PO RAT I t�(�; TRUSS ENGINEER@NG BUILDER: RENAR v PROJECT. MORNINGSIDE ui COUNTY: ST LUCIE LOT/BLK/MODEL: LOT:12 / MODEL:CAYMAN 1763 / ELEV:B1 / GAR R I JOB#: 75659 MASTER#: WRMSCM1763131 OPTIONS: NO OPTIONS Lumber design values are in accordance with ANSIfTPI 1-2014 section 6.3 ti A-1 ROOF These truss designs rely on lumber values established by others. TRUSSES AFLORIDA CORPORATION RE: Job WRMSCM1763B1 A-1 Roof Trusses 4451 St Lucie Blvd -Site Information: - - - - Fort Pierce, FL34946 Customer Info: RENAR DEVELOPMENT CO. Project Name: MORNINGSIDE Lot/Block: Model: CAYMAN 1763 Address: Subdivision: City: County: St Lucie State: FL Name Address and License # of Structural Engineer of Record, If there is one, for the building. Name: License #: Address: City: General Truss Engineering Criteria Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017frP12014 Design Program: MiTek 20/20 8.2 Wind Code: ASCE 7-10 Wind Speed: 160 Roof Load: 37.0 psf Floor Load: 0.0 psf This package includes 37 individual, dated Truss Design Drawings and 16 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003,section 5 of the Florida Board of Professional Engineers Rules. No. Seal # Truss Name Date No. Seal # Truss Name Date No. Seal # Truss Name Date 1 A0214409 A01 3/5/19 13 A0214421 B01G 315119 25 A0214434 HJ7 3/5/19 12 A0214410 A02 315/19 14 A0214422 B02 3/5/19 26 A0214435 HHA 3/5/19 3 A0214411 A03 3/5/19 15 A0214423 B03 315/19 27 A0214436 J7 3/5/19 4 A0214412 A04 3/5/19 16 A0214424 C01G 315/19 28 A0214437 J7A 315119 5 A0214413 A05 3/5/19 17 A0214425 CO2 315/19 29 A0214438 T01GE 3/5119 6 A0214414 A06 3/5/19 18 A0214426 CO3 3/5119 30 A0214439 T02 315119 17 A0214415 A07 3/5119 19 A0214427 C04 3/5119 31 A0214440 T03 3/5119 8 A0214416 A08 3/5/19 20 A0214428 CA 315/19 32 A0214441 T04 315/19 9 A0214417 A09 3/5/19 21 A0214429 CJ3 315/19 33 A0214442 T05 315/19 10 A0214418 A10 3/5/19 22 A0214430 CJ3A 315%19 34 A0214443 T06 315119 11 A0214419 All 3/5/19 23 A0214431 CJ5 315119 35 A0214444 VM03 315/19 12 A0214420 Al2GE 3/5/19 24 A0214432 CJ5A 3/5119 36 A0214445 VM05 3/5119 The buss dmw ng(s) reterenced have been prepared byMiTek Industries, Inc. under mydirectsupervision based on the parameters provided byA-1 RooiTrusses, Ltd. Truss Design Engineer's Name: Anthony Tombo III My license renewal date for the state of Florida is February 28,2021. NOTE -The seal on these drawings indicate acceptance of professionalengineering responsibTRysolelyforthe buss components shown. The suitabilityand use of components forany particularbuilding is the nsponsibility of the building designer, perANSUPIA Sec 2. The Truss Design Drawing(s)(TDD[s]) referenced have been prepared based on the construction domrnents (also referred to attknes as'Structural Engineering Docurrentsj provided by the Building Designer indicating the nature and characterof the work The design criteria therein have been transferred to Anthony Tombo III PE by [Al Roof Trusses orsperific location]. These TDDs(also referred to attimes as'Structural Delegated Engineering Documents') are specialty structural component designs and may be part of the projects deferred orphaned submittals. Asa Truss Design Engineer(ic., Specialty Engineer),the seal here and on the TDD represents an acceptance of professional engineering Anthony T. responsibTityforthe design ofthe single Truss depicted on the TDD only The Building Designer's responsible forand shall coordinate and review the TDDs for compatrbi7itywith theirwrhten engineering rquina ents. P1easereviewaI1TDDsandallretatednotes. ..�.... _.-._. iq rt. " 4d36b989999e20a51b6cde8e Page 1 of 2 A-1 ROOF TRUSSES AFLORIDACORPORATION RE: Job WRMSCM17631211 No. Seal # Truss Name Date 37 A0214446 VM07 3/5/19 38 STDL01 STD. DETAIL 3/5119 39 STDL02 STD. DETAIL 3/5/19 40 STDL03 STD. DETAIL 315119 41 5TDL04 STD. DETAIL_ 315119 42 STDL05 STD. DETAIL 3/5119 43 STDL06 STD. DETAIL 315119 44 STDL07 STD. DETAIL 3/5/19 45 STDL08 STD. DETAIL 315/19 46 STDL09 STD. DETAIL 315/19 47 STDL10 STD. DETAIL 315/19 48 STDL11 STD. DETAIL 315/19 49 STDL12 STD. DETAIL 315/19 50 STDL13 STD. DETAIL 315/19 51 STDL14 STD. DETAIL 3/5/19 52 STDL'15 STD. DETAIL 3/5/19 53 STDL16 STD. DETAIL 3/5/19 Lumber design values' are in accordance with ANSI/TPI 1-2014 section 6.3 w These truss designs rely on lumber values established by others. Page 2 of 2 Job mss I russ I ype Uty Vly RENAR MORNINGSIDE A0214409 ftMSCM176391 A01 Raof Spedal 1 1 Jab Reference (optional) hry Koor krises, ronnerve,m a¢ b,oesign(walauss.com 5x6 = 6.00 12 5x6 = 6 2 o� 7x14 MT20HS= 23 22 17 - 15 -114V' 3x6 = 4x6 = 2x4 It 2x4 II 3.6 = 1.5x4 II 3.6 = 6.8 = LOADING(psf) SPACING- 2-M CSI. DEFL, in (loc) I/deb Vd TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(LL) 0.71 17 >641 360 TCDL 7.0 Lumber DOL 1.25 BC 0.88 Vert(CT) -1.30. 17 >350 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.98 Horz(CT) 0.76 12 n/a n/a BCDL 10.0 Code FBC20171TP12014 Malnx-MS LUMBER - TOP CHORD 2x4 SP No.2 *Except' T4: 2x4 SP 2400F 2.0E BOTCHORD 2x4 SP No.2 *Except* B2: 2x4 SP No.3, B3: 2x6 SP 2400F 2.0E WEBS 2x4 SP No.3 *Except' W3,W5: 2x4 SP No.2, W9: 2x4 SP M 30 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 5-M oc bracing. WEBS 1 Row at midpt 15-18, 9-18, 7-20 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 148210-7-10 (min. 0-1-12) 12 = 1482/0-7-10 (min.0-1-12) Max Horz 2 = -138(LC 10) Max Uplift 2. _ -347(LC 12) 12 = -399(LC 13) Max Gmv 2 = 1482(LC 1) 12 = 1482(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-2716/1647, 3-4=4515/2570, 4-5=-4439/2579, 5-6=-3690/2112, 6-7=-364312109, 7-8=6247/3440, 8-9=-7597/4126, 9-10=2076/1389, 10-11=-215611372,11-12=-2692/1630 BOTCHORD 2-23=-1305/2374, 5-21=-257/518, 20-21=-1999/4064, 19-20=-3014/6320, 18-19=3774/7833, 8-18=-102612283, 14-15=1299/2350, 12-14=129912350 WEBS 3-23=-1156f767, 21-23=1464/2649, WEBS 3-23=1156f767, 21-23=-1464/2649, 3-21=659/1598, 6-20=-168913032, 7-19=664/1413, 8-19=-2642/1325, 15-1 8=1 088/2335, 9-15=-1105/529, 11-15=5711501, 11-14=0/265, 9-18=2924/5988, 5-20=-813/638, 7-20=429112281 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exledor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 6) `This truss has been designed fora live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=11b) 2=347, 12=399. LOAD CASES) Standard Dead Load D.h. = 518 in PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 234 Ib FT = 10 r.m9 n :ra ^sdr n 9P gp ns9nf,me3 ax4alxwx9ermu 99vn?ui¢nW NMM n,an t,tlrl,dPPwamel94 W ga.,nm %C,14 A,3W ."" N Mr,nr gam Eemend mrn ny mt �r axa dbdluanW dt9 t :rt:nfm..A y.W,(r�Y2udn w,m, per6mxW ma ++•cow llf 9n .'m:.P<t ry,4 mrn Wp d. ml .kb:lrmr.p.ats wsa-. Anthony T. Tom69IIl, P.E. M dn.�rnt Fk 'dmpnublmdp9 m9.ur,salM r!:4Mfm9nyx Y'Wad: o:.x 9. IB kit 4q W41!:. am'o6M Mb d6 tm v.eg9argane e,hlMwnihxnilxMd gn :,tl a 9,eya,..wuwmm..0 s,a.n.mtwn•rmnwpxlw dwnunr.9*endm :mrpw.lhm 4Wl M rr rl x;nryeaw9aurralmuvy. um[m„9.�nwrm.x„a. .n:n >90083 rx m18.,, 6xWrprdmu.vSgllApcxnfid Ipin•vW try 1n+.Hx,9 1.. srr rywnd t.an m e.d .w.tnt 44515t. Lurie 3494 G :ib111PlFA-IPwl6nnes Fod Pierce, rL 349<6 p19 Aa6mp11vm9a N, N. Psp v4ua..idnlamno:. g6,m,,gmAlhrd i6en Mr.nd.pxnu vM1v dArvdUesas Axlhvvpi.ramtolO,Pl. Job Truss Nas yp¢ ty y RENAR MORNINGSIOE ^ A0214410 WRMSCM1763BI A02 Hip 1 1 Job Reference o lional [ A-1 Roof Trusses, Fad Pierce, FL 34946, design@a18uss.00m Run: 8.210 s May 18 2018 PH ID:ld 1OXyyT61E r7-0-0 G-SB 1t-10_10 74-0-0 t9414 24-0-0 5-5_1 2-145 I 5-0-14 I 411-2 r 6.0012 7x611 2x411 5x10= Tue Dead Load Dell. =1r2 In 18 17 14 13 12 3z6 = 4x6 = 2x4 II 2z4 II 6xe = 1.5x4 II 3x6 = G6-8 it-70.10 14-0-0 19-0-14 24 :238-00 65-8 5I 2-1E 1 5.14 4-11-2 4.. 9 3-0 Plate Offsets (X,Y}- (4:0-3-O,Edgel, I8:0-8-0,0.2A1, f9:0-3-0,0.3-41 [13:0-2-4,0-3-0](15:04-00-3-81 [16:0-2-8 0-3-0] LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Well Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 125 TO 0.96 Ved(LL) -0.51 14 >896 360 MT20 2441190 TOOL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.99 15-16 >462 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.93 Horz(CT) 0.56 10 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MS Weight:2201b FT=10% LUMBER - TOP CHORD 2x4 SP N0.2 *Except* T1: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 *Except* B2,B4: 2x4 SP No.3, 133: 2x4 SP M 30 WEBS 2x4 SP No.3'Except* W3,W6: 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied. BOT CHORO Rigid ceiling directly applied or 2-2-0 oc bracing..._ - WEBS -1.Row at midpt 8-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1482/0-7-10 (min.0-1-12) 10 = 1482/0-7-10 (min. 0-1-12) Max Horz 2 = -126(LC 10) Max Uplift 2 = -335(LC 12) 10 = -335(LC 13) Max Grav 2 = 1482(LC 1) 10 = 1482(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-2703/1619, 3-4=-4181/2350, 4-5=4106/2368, 5-6=-4156/2478, 6-7=-5484/2973, 7-8=-5430/2965, 8-9=-2056/1382, 9-10=-2556/1526 BOTCHORD 2-18=-1276/2361, 5-16=-190/256, 15-16=155313453, 7-15=-283/281, 12-13=115712198, 10-12=1157/2202 WEBS 3-18=-1114r726,16-18=-1428/2649, 3-16=-492/1316, 6-16=-5361734, 6-15=-1 081/2362,13-15=1058/2407, 8-15=1904/4121, 8-13=-11741422, WEBS 3-1 8=1 114/726, 16-18=-142812649, 3-16=-492/1316, 6-16=536r734, 6-15=1081/2362, 13-15=1058@407, 8-15=1904/4121, 8-13=11741422, 9-13=-625/541, 9-12=01330 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13f ; at. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exierior(2)zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water poniing. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of muss to bearing plate capable of withstanding.100 in uplift at joint(s) except (jt=lb) 2=335, 10=335. LOAD CASE(S) Standard r :q x„.e.,ger rn nmc nvsfJtlmla n.tnrwu atznrmux(xlr;l mks .,v ri cxalxann wvJ �v+n• I xnx,.y ns..a ldorrl Ixlun a.G:r-. warmw mM alm 1 - bl it Jn l•.tlMMrmpkwr ter ,ae a6 vVMtl Ivv ,pu' pm[hp[u.n ryry.w IM4MN [a.yl y'9 Minml a,lib[v '^p+u.8+n tl'r1 11h1n Tam6n RI, P.E. e[ n ,I,n3 MWllyl M p,.i6Nnh0 MP V,oi,ley.9 h414ap ryr 4 - nhICM0. WMbM1 Mlnl tlh.WNwIW dWi YM- ylui 'f i9 dNnidtai4 80083 hH[.pm,gx rtl4Cvht ram nloo amr'-n eJ9.✓.tin nxdngwlvn wma, mvplwllllndau axg N wl aAu x+,S.ut f riel mulu.,I.mh,m4nu Wlml .rn,+.. 4451 St. Lucie d 'uldudlPOfm Ptlwu�mmgll[IPnm Md ei ru ln• - q brClbldxrG 1, 11 bluru[ IIWbq fii nitlNnnVl. Blvd. � Fort Pierce, FL 34946 6plrgdl01616 A I bdinsul-AnlavyLlvm6a IIL/.!. Aeprvdeaiav vl0ndvmxerl, nngimgnprd IhdmlEMlde.nnee pemhlwehan Ml lvAinvo-AsmmrLhMelll, P.I. Job Truss I rus5 I ype RENAR MORNINGSIDE Ao214411 ?VRMSCM1763B1 A03 Hip IQIY 1 1 Job Reference (optional) N%-j Hool ,fusses, von vience, rL J hhib, oeagngal wss.Win may 5.6 = 6.0012 2x4 II 7x611 n 7 n 19 18 15 14 '-' 12 3x6 _ 4x6 = 2x4 II 2.4 II 8.8 = 3x6 = 1.Sx4 II 3.6 = Dead Load 0e6. = 7116 in fi-5-8 I 11-C10-10L1 l 161-0 119-0-14 r1.s.a d_1_6 zn_1a P_11_P n_9l1 o.u6 Plate Offsets (X,Y}- 14:0-3-O,Edgel 16:0-3-00-2-01,18:0-1-12,0-1-121 19:0-3-0Edger 114:0-2-0 0-2-81 116:0-2-12 0-3-01 rl7:0-2-8 0-3-01 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.90 Vert(LL) -0.39 16-17 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.96 Vert(CT) -0.8216-17 >555 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.88 Hmz(CT) 0.48 10 n/a We BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 224 lb FT = 10 LUMBER - TOP CHORD 2x4 SP No.2 *Except* T1: 2x4 SP M 30 BOTCHORD 2x4 SP No2 "Except" B2,B4: 2x4 SP No.3 WEBS 2x4 SP No.3 *Except' W3,W7,W6: 2x4 SP No2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 o0 pudins. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpl 8-14, 9-14 MiTek recommends that Stabilizers and required cross bracing be installed during muss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 148210-7-10 (min. 0-1-12) 10 = 1482/0-7-10 (min. 0-1-12) Max Hom 2 =-142(LC 10) Max Uplift 2 =-350(LC 12) ,10 =-350(LC 13) Max Grav 2 = 1482(LC 1) 10 = 1482(LC 1) FORCES. (lb) Max. Comp./Max. Ten- - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-270111638, 3-4=4183/2394, 4-5=-411112412, 5-6=4198/2578, 6-7=-387312180, 7-8=-3837/2173, 8-9=-1915/1300, 9-10=-256311551 BOTCHORD 2-1 9=-1 292/2359, 5-17=-265/347, 16-17=-1354/3171, 13-14=-1184/2207, 12-13=-1184/2207,10-12=-118312210 WEBS 3-19=1111R32, 17-19=-1442/2643, 3-17=519/1323, 6-17=79111010, 6-16=46111183. 14-16=-1288/3106, WEBS 3-19=1111/732, 17-19=1442/2643, 3-17=-519/1323, 6-17=-79111010, 6-16=-46111183, 14-16=-128813106, 846=-149413533, B-14=-2174/826, 9-14--721 /619. 9-12=01359 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=42psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 60b) 2=350, 10=350. LOAD CASE(S) Standard rq ur:MgN 1#NnC II'f1R N.IfIl&ItIIRIYS![JMIIPinRal(0.TPLfi E3Afr N,I.If hilpp,aanvW xlMnv 1 Y h N'I[v olhlMil.lwl L..1111 LrvJM4 OMmhv 9d U. f tlr Ylvil, l,e WYnNh.MrAl4 tldr 1 rinThpn6 f tlh6Y aax iln.P pi4bPtlwmhuemlml,WWYaMpKhsyl ve.l N6vitrWPFI },Lp vop hu ^+ilt Mthony T. Tombo 111, P.E. I r1 u/Mtlm S yl Ifv" v3.ly p tlh0 YO !nrv-cd ,N Yhx hq Y P $aIY,WInM+t Mra1AI } yy, tlh tOdaAYI 6hl . irtalary _ Ndpw MY MYh 1 y 80083 hHxryY:Se rx.c _ ,w.e hrWal pmlalptlx. In YbgWaaYlgba •xu.Mwerlfnwvu.,m.mnhia.vM >rIY..e„m=, Orn[a,1 Yv, l+.,ml,Yaaa.n p,eout. 4451 St. Lucie Blvd. ne.Hlem+tr a�H,m,^hlbrAr. Imhuhvp[y. nhw.l Yua i m.aaurarlv4 ldmwar 6s aYnu con Pierce, FL 34g46 trppg6i 0X16 A I Lutravz Arlo, IJ.da 1% H. op*bIld.46mii6e rrmn pbmifum hrnLl lmthirms-4dmrT.IrNalµ P-[. Job Inuss was I ype uty PIy RENAR MORNINGSIDE - A0214412 WRMSCM176381 A04 scissor 1 1 Job Reference (optional)_ e' A-1 Roof Trusses, Fort Pierce, FL 3494 6.00112 5x6 = Sxfi = Dead Load Deb. = 9/161n 6 5x6 i 4 4 1.Sx4 C W 3 13 W 5.12 = 5 14 1 2 3x8 MT20HS� 3x4 3.00 12 4x8 5xea 7 3x4 c 1.5x4 II 1.5x4 II 30.945 1.5x4 4 8 1 91 101'^ Al. „ o 5.8 1.5x4 II 4x8 // 9-164 9: 190d &1-12 27-1$ &1$ 1- 2 31 $ 2$d 7 610.10 38-0-0 Plate Offsets (X Y)- 12:0-1-14 Edgel. (4:0-3-00-3-01. 15:0-3-0,0-2-01, 16:0-3-0,0-2-01 17:0-3-00-3-01 - Edgel (9 19:q: :0-4-0 U,11 (9:0-2-1 Edgel LOADING(psf) SPACING- 2-M CSI. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 .54 13-15 >845 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.84.05 7H.64 13-15 >432 240 MT20HS 1871143 BOLL 0.0 ' Rep Stress Incr YES WB 0.63 9 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 205lb FT = 10 LUMBER - TOP CHORD 2x4 SP N0.2'ExcepC T1: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Left: 2x4 SP No.3, Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-8-14 oc pudins. BOTCHORD Rigid ceiling directly applied or4-7-12 oc bracing. Except: 4-8-0 oc bracing: 9-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 148210-7-10 (min.0-1-11) 9 = 1482/0-7-10 (min.0-1-11) Max Horz 2 = -158(LC 10) Max Uplift 2 = -363(LC 12) 9 = -363(LC 13) Max Grav 2 = 1482(LC 1) 9 = 1482(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-4679/2796, 3-4=-4312/2515, 4-5=-3133/1773, 6-7=3133/1773, 7-8=-4339/2540, 8-9=4664/2815, 5-6=-3005/1785 BOTCHORD 2-15=2389/4236, 14-15=-1802/3597, 13-14=1797/3633, 12-13=-179913634, 11 -1 2=1 812/3599, 9-11=-2406/4248 WEBS 7-13=8181756, 7-11=-272/634, 8-11=328/457, 4-13=8167750, WEBS 7-13=8187756, 7-11=-272/634, 8-11=328/457,4-13=-8167750, 4-15=268/626, 3-15=327/476, 5-13=-639/1239, 6-13=-638/1238 NOTES- 1) Unbalanced roof live leads have. been considered for this design. . 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; End., GCpi=0.18: MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed:C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 lost bottom chord live load nonconcument with any other live loads. 6)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2, 9 considers parallel to grain value using ANSIITPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (lt=lb) 2=363, 9=363. LOAD CASE(S) Standard xeu9 rmru hY1nG.lYfl Vnflj9dIF1131410 (llrYlkT ,n[i,su114 IrA1 ddP1 tlV drlur nl OnA890%: r1,4elll nGtl lh Vw.4N NItPo- tld dTUA,} emrmx,fYY PAL• Imrraa ,. +,tt 1 1PI P^x{ 1 J.Pnm + arrxn m+rq.,wlmnteLryrru Ertpr 1 rnm�n .,bmlr Y.r •x Idy widen Anthony T. Torive N,uJktlmb klyld ,ry.Wn/ ] _ f br' &F 4 tl H. .Tdrhil YlJe fIM I19F^tlrOEWmLY tlfi. ffi1rLM 9. WI9odY v1 N'.J a80083 MNYgp,lrt dfec,.^n i w rIW WmW. WM9 MmL'enh' pYlrthM1!p1iINV11 M Ubprtl P4� IYIG .!'eyes�T rxsYa,l n.huWrlmtMTupe .t .Y+Wzy sks. 44515L Woe Blvd. rfe.lulb,rll 4fe PU, x+shdr- r. I. r f1 4r1 t,e i rt gmrtJWMdW Nn4de14. lid IY.I Fort pierce, FL 34945 Iep,i,1l01016A I Karr..sss hllurpl.T.h1ll P.I. Pep NYa d4tlomnml,u4glme,rspmhAnedrnhelndrnnmpam nrrhemAlltlolLmsu AvreeoyLDdFolll, Pl. JO�� N55 Nss ype ly y RENAR MORNINGSIDE 4SRMSCMI]6381 A05 Stlssor 2 1 A0214413 Jab Reference (ootionall 6.00 12 5x6 = 5 5.6 G 2 5x6 1.Sx4 w 3 Sx4 3 7 12 1 W 6x8 = 8 14 13 11 0 cg 1 2 Us MT20HS% 3x8 W20 6— 3x4�- 30012 _ x4Z7 15Y1459441,- ` 1.5x4 11 1.5x4 II 4x8 —' - - 30.315 -- — 9-1gd 1460k 2]-1-6 2 1- 2 3f -6 W 9-ind 9-1-f2 s_1-6 2$4 7 6-1 Plate Offsets (X Y)- f2:0-1-14 Edgel [4:0-3-0 0-3-0]16:0-3-00-3-01 f8:0-3-7 Edgel 18:0-40 0-5-41 18:0-2-1 Edgel LOADING(pso SPACING- 2-M CSI. DEFL. in (too) I/defl L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.55 12-14 >826 360 TCDL 7.0 Lumber DOL 1.25 BC 0.84 Vert(CT) -1.07 12-14 >425 240 BCLL 0.0 Rep Stress [nor YES WB 0.93 Horz(CT) 0.65 8 n/a n/a BCDL 10.0 Code FBC2017/7PI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP N0.2'Except` Tl: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 nc. purins. BOT CHORD Rigid ceiling directly applied or4-7-10 no bracing. Except 4-8-0 oc bracing: 8-10 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 148210-7-10(min.0-1-11) 8 = 1482/0-7-10 (min.0-1-11) Max Horz 2 =-166(LC 10) Max Uplift 2 =-369(LC 12) 8 =-369(LC 13) Max Grav 2 = 1482(LC 1) 8 = 1482(LC 1) FORCES. (lb)_ Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=467612810, 34=4314/2537, 4-5=-3129/1785, 5-6=-3129/1785, 6-7=-4341/2562, 7-8=4660I2828 BOT CHORD 2-14=2402/4233, 13-14=1831/3605, 12-13=-182713640, 11-12=182913643, 10-11=-1842/3607, 8-1O=2418/4245 WEBS 5-12=127812430, 6-12=-850/786, 6-10=262/633, 7-1 O=319/445, 4-12=848/781, 4-14=-257/625, 3-14=318/465 WEBS 5-12=12782430, 6-12=-8501786, 6-10=262/633, 7-10=-319/445, 4-12=-8481781, 4-14=-257/625, 3-14=318/465 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=134; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extenor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load noncencurrenl with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSlrTPI 1 angle to grain formula. Building designer should venfy capacity of bearing surface. 7)13rovide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=1b) 2=369, 8=369. LOAD CASE(S) Standard Dead Load Deft. = 9116 in 5x8> 1.5x4 II PLATES GRIP MT20 2441190 MT20HS 1871143 Weight:198lb FT=10% S uq lkr Wn9tl Int 11:i56(vLfli&il'13g5t( ]Wit 1YI ImYkar Aft i4i5upg p rq lq apt fe;a9uq.IkNWLivH.1 YC.itltiv LM Ah Wd tl1fB ] pIl Rn:tltli HY Ilu iJ]U Nil.l gnT19r Y vW ,g1P9Rp m' S tl PY IM^i �N NiM Mkt 1 L M1W .M I 1 -k H mG ' ,a ,14v1,rs s fir n E. _ - - n p" v Anthony T. TomCa FII, P. N 9 i.plptl'u M. h[n S�v. ,rte kl4 kp `w ,RnAMW -S iMM!!%zgM llxl 'pR€^t tldTPal WY tl xl Mxa. 'ReXMINaNh:nWkM f I =90693 Mg-git'r"' iw'^m 1. ,em MlppWMp. w/p!•Jv M1YdM T Nm1 E, 'C.trol:M ltlndVn tl lbinm ib ttik .aymM 3G.. YS➢nMprl lrg tan it,.tlmina ax.. g aluitlpefY ,m:m pea `�tiidlM ,et 1'.1 u R f Ic wnerge 1 �� cot MPR m,R .. i8adl nu.. �'4516[. Lucie 01vd. � (oppiigEtlOIDlpAiboitnfut lnimylfombollLYl.gep•tltlwo o0bn pnmmem, Paglwm.apme4dedwttdnlWe rntlee pmwmahgmAlPodLeuerAdon r.itlmbaili, P.L-_._._. _ Portpi'e2e, FL 34946 Job Truss russ I ype Qty Ply RENAR MORNINGSIDE ^' A0214414ssor WRMSCMI763B1 AM Sd 10 1 Job Reference (optional) k A-1 Roof Trusses, Fort Pierce, FL 34946, design@a15uss.mm Run: 6.00 12 5x6 = Sx6 i 5x6 6 1.5x, 3 5x4G 3 7 12 w 6x8 = 1 B 74 13 11 10 1 1 2 — 3x8 MT20HS% 3 00 12 3x8 A4T20HS> 3x4 s F 3x4 4x8 c 4x8 9-104 19-M 28-1-12 I 38-0-0 i 9-104 9-1-12 9-1-12 9-1 GA Dead Load Dell. = 9116 in Plate Offsets (X,Y)- (2:0-1-14,Edgel. I4:0-3-0,0-3-01 16:0-3-0,0-3-01, 18:0-1-14,Edgel LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.66 Ved(LL) 0.5712-14 >806 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.84 Ved(CT) -1.1012-14 >416 240 MT20HS ' 187/143 BCLL 0.0 ' Rep Stress Incr YES WB 0.93 Horz(CT) 0.68 8 n/a n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MS Weight: 1751b FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 *Except* T1: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 4-7-7 oc bracing. Mil- Tek recommends that Stabilizers and required - cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1482/0-7-10 (min. 0-1-11) 8 = 1482/0-7-10 (min.0-1-11) Max Horz 2 = -166(LC 10) Max Uplift 2 = -369(LC 12) 8 = -369(LC 13) Max Gmv 2 = 1482(LC 1) 8 = 1482(LC 1) t'FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-4676/2809, 3A=-4314/2536, 4-5=-3130/1786, 5-6=3130/1786, 6-7=-4314/2551, 7.8=4676/2830 BOTCHORD 2-14=-2401/4233,13-14=-183213605. 12-13=-1827/3641, 11-12=183213641, 10-11=-1837/3605, 8-10=-2423/4233 WEBS 5-12=-127912431, 6-12=8487779, 6-10=-254/625, 7-10=-318/464, 4-12=-848t780, 4.14=-256/625, 3-14=-318/465 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsi; h=13ft; Cat. II; Erp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psi bottom chord live load nonconcument with any other live loads. 5) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2, 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at --lb) 2=369, 8=369. LOAD CASE(S) Standard r,I a..,dy AIN: m»a un eaaf nm4[ouniomrmllelun;ram. a'm c,:a,kn.w+,m+r,dra, o-I. kpn,«y.n auwrLrrweu ra 9 kwr oa„ aaa nm y ou,o-.+r .a a rmaar .air k.1 ry . n 1ra,ne.r .a ma.mm psa Mae gvemf^y ru iamp a,M r ayrl.aIDo.p b,wi asp -r rY tman xvkan Anthony T. Tombo 111, P.E. rmtln,r,:a I nw-ean.aaa o .evrr.Pa a1.' m d P,&raad6 agrrefw1nm-daN rn.bu aarmsaing6rttl.ml nrd rp w a: `rv'a'—.a a$0083 amdgk,mr, . 1mr v rP+d� an wyr vme>+�'n✓raraa4rnrdum ',F enlhrmPam Vrlk ,a „Pa*lasrea,ds•vvkvp�r tm,k,pnre„rr srm...,.'..: n,melary ro r.r..xegMmin ,mr,.ssq,r�[gmu�rut r tsrpr 1 �, der kdaq aawmark mNC1fII. 44515E Lucie Blvd. a h®IDI6411"Ihns fort Pierce. FL 34946 @nr srs-M6unrL7ololllp}. Iep pneeeleUom.ee,,,Daum,wrspd�ndru6M,6er,mnpe,minwleoAlBed Lmss, AMnnri. ren.olll, P.l. 0 + rusa russ ype ry y RENAR MORNINGSIDE A0214415 iNRMSCM1763B1 A07 Roor Special 4 1 Job Reference o lional Atj Roof Trusses, Foci Pierce, FL 34946, deegu@alBuss.com Run: 8,210 s May 18 2018 Print 8.210 s May 18 201B MITek IndusNes, Inc. Tue Mar 514.29:12 2019 Page 1 ID:ld_00XyyT61 Bi_TXoljwH HzefvK-cgm4hQPkUF1JN W U3Fm2t7dx7N UGi W OVI7PhxCazdyfr 112 2815 38-0-0 9J 8 3d &-0 F.1100 7--04-1238-0-1 4 6.00 12 7x6 = .1 4x10 = 3.6 = 5.6 = h4 II 1.5z4 II 3.00 12 3x8 8x8.= 1.Sz411 11-7-10 21.2-10 2 2 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ltd TCLL 20.0 Plate Grip DOL 1.25 TC 0.96 Vert(LL) 0.44 10-11 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.85 Vert(CT) -0.82 10-11 >559 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.87 Horz(CT) 0.46 8 We n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2'Except' T1,T4:2x4 SP M 30 WEBS BOT CHORD 2x4 SP No.2'Except' 3-17=467/341, 14-17=112512283, B2,64: 2x4 SP No.3, B5: 2x4 SP M 30 4-13=1033/798, 5-13=413/69, WEBS 2x4 SP No.3 *Except' 7-11=-85Of751, 7-10=01293. W6: 2x4 SP No.2 11-13=665/1840, 5-11=-1595/2992 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 4-9-3 oc bracing. Except 10-0-0 oc bracing: 14-16 WEBS 1 Row at midpt 4-13, 5-13, 5-11 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation quide. REACTIONS. (lb/size) 2 = 149110-7-10 (min. 0-1-12) 8 = 1485/0-7-10 (min.0-1-11) Max Harz 2 = -166(LC 10) Max Uplift 2 = -365(LC 12) 8 = -367(LC 13) Max Grav 2 = y -8 1491(LC 1) _--^ 1485(LC 1) FORCES. (Ib) Max. Camp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-2635/1604, 341=2700/1747, 4-5=-1822/1250, 5-6=3652/2302, 6-7=-3743/2165, 7-8=-467712738 BOT CHORD 2-17=-123312283,4-14=-313/657, 13-14=-1251/2421, 6-11=-276/340, 10-11=-232914220, 8-10=-232614219 WEBS 3-17=467/341, 14-17=-1125/2283, 4-13=-1033/798,5-13=413/69, NOTES- 1) Unbalanced roof live loads have been considered for thisdasign. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18: MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces R MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 8 considers parallel to grain value using ANSUTPI 1 angle to grain formula. -Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstandfdg 100 Ib uplift at joint(s) except Qt=1b) 2=365, 8=367. LOAD CASE(S) Standard Dead Lead Dell. = 318 in �J1 PLATES GRIP MT20 244/190 MT20HS 187/143 Weight: 2201b FT = 10% anna�m qe mono-Ils,nf,uuTurmnwlunanrtxenx scrr-. c-„etrl t.arkur�e,.nmrineran.nr a•na w'n..�trt�Anrll eflu a oa as eea eroy nit ,m:mr. Ae .da nnai kNta r.4hvm(p+J tr. $0.w+ axmromxm,n a+a rt myanvl rymuurywnek trm/r-dxd ,loorara Iqi I1 p wx1 vnwar Andiony T. Tambo 111, P.E. tl aanla 4 MW q'.bITa69 trf.n�,exd Ta htafi OOA'a '.zaee dbltl.h 0.s1M6i1 Mq Mrd0.11 iF rim OJW Iml Fa 1 Irtg4f'4 - J IYn JiifGe y Y+ -80083 kwo'lnl rsmx r- .r.n,rw.dtrr mnmpa ie Pmgaw �mt.., wrdouNgmrauu a„mar aeas I. I a, �+ leaaraln ddr^.i« Inpnrn.mlm.:e.,em< 4451 St. Lurie Blvd. 1u•a,dexat! rw,eepetlnn �mghdlp!xwae10, 4.�&m ael3t.lq .to r fre fgmnr rNAq 11IG9'a4a admAann- FOR Punce. FL 34946 (appijkl0silt"JudImai Ankoq Uombo&Fl. lep d.o�oeollA s{ormal,mmllmm,np:ol3ned.tArmtle rlineepumisuerhamAllvclLnses-AnErnfl.Lmlu III,P.L _. Job Fruss I was I ype Qty y RENAR MORNINGSIDE ^' A0214416 WRMSCM1763BI A08 HIP CAT 1 1 Job Reference (op6ona0 0' A-1 Roof Trvsses, Fall Pierce, FL 34946, design@a10uss.cem Run: 8.210 s May 18 2018 Print 8.210 s May 18 2018 MiTek Industries, Inc. Tue Mar 514.29:13 2019 Page 1 ID:Id_OOXyyT6181_TXoljwHHzefvK-50JSumOMFYnAy3FpTZ6frUM8tbzFrCvD3RW Ozdyfq 26n-10 1i4 61-11 11-1-10 18Al2 1111 2. 304-11 ]B40 +194-0 rt-0 bum I an-1s I bn-2 11-1M- 1248I J.1-e I Ja-s 146 6.00 F12 Sx10 % 5x8 II ASA O SX10 MT20HSG 7 4 4 5x6 3x4 G 3 W4 to 9 I.SX4 1 a1 J9e= 5 W 1.4 2 12 - 16 15w--- •_ -^. -3x4a 20 19 18 2zd II 3x4 = 1.5x4 II 4.8 3x6= 6x6= 3x411 4x18= 3.0012 Bx8 = Dead Load Den. = 318 in 1.Sx4 II 20.11-103 2 _ 61-11 11-1-10 11710 1M2 1&11 1023,3-2 30-0-11 38-0-0 61-11 4-11-15 Xf fi-S2 1-10.8 0 0 s 1-04 1-98 Plate Offsets (X,Y)— 14:0-5-0,0-3-01. 16:0-2-4,0-2-81, f8:0-1-15,0-0-01 19:0-0-0,0-1-121, f9:0-3-0Edgel f10:0-1-14 Edgel 113:0-5-12 0-5-01 117:0-5-12 04-0] LOADING(pso SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.70 Vert(LL) 0.48 12-13 >957 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.85 Vert(CT) -0.90 12-13 >507 240 MT20HS 1871143 BCLL 0.0 Rep Stress Incr YES WB 0.84 Horz(CT) OAS 10 n/a War BCDL 10.0 Code FBC2017/TPI2014 Matdx-MS Weight:246lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2'Except' T4,T5: 2x4 SP M 30 BOTCHORD 2x4 SP No.2 *Except* B2,B4: 2x4 SP No.3, B5: 2x4 SP M 30 WEBS 2x4 SP No.3'Except• W7: 2x4 SP No.2 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-8-8 be pudins. BOTCHORD Rigid ceiling directly applied or4-8-13 oc bracing. Except: 10-0-0 oc bracing: 17-19 WEBS 1 Row at midpt 4-16, 5-15, 6-15, 7-12, 6-13 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 2 = 1491/0-7-10 (min. 0-1-12) 10 = 1485/0-7-10 (min.0-1-11) Max Horz 2 = -159(LC 10) Max Uplift 2 = -359(LC 12) 10 = -362(LC 13) Max Grav 2 = 1491(LC 1) 10 = 1485(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORO 2-3=-2721/1649, 3-4=-2695/1686, 4-5=-1883/1280, 5-6=-1590/1234, 6-7=-3886/2415, 7-8=-4665/2990, 8-9=4517/2737, 9-10=4689/2737 BOTCHORD 2-20=1302/2377, 4-17=-225/587, 16-17=-1222/2400, 15-16=619/1610, 7-13=-518/621, 12-13=-167713641, BOTCHORD 2-20=1302/2377, 4-17=-225/587, 16-17=-1222/2400, 15-16=-619/1610, 7-13=-518/621, 12-13=-1677/3641, 10-12=2333/4230 WEBS 3-20=-2661250, 17-20=1175/2215, 4-16=961/733, 5-16=-300/626, 5-15=271/106, 6-15=-13401496, 7-12=-839/889, 8-12=-345/505, 13-15=-81412158, 6-13=-1832/3531 NOTES- 1) Unbalanced root live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8, MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=1b) 2=359, 10=362. LOAD CASE(S) Standard .'i m:.,n n.n,dr v +- a;erxwtmwsFmnrmr,a«ree•0 ea 1.1+'„wr.rb. 'xx;r�' Invdwl n fv rs..tMxro.le:�sannta,nta nn11E ed irnagFEMas,xrtLTvinu Nup(9m I1.J Y4a1x1E p L rexfen JWNfy W�ptlad MdM1Un. D AIdA i foe Lvues-AnlnnrCTomEr111, P.I. IvplWvdioevlth rem,.nvn, oagblm,up1o134v4.,lEamde. mvv Fr nix whom 41 Neolkean�Ae:dOnri. irnEoN, P.[. Anthony T. Tomb0111, P.E. 33083 4a51 St. Lucie Blvd. Fort Pierce, FL 34946 Job- Truss Inuss lype ty y RENAR MORNINDSIDE A0214417 �/RMSCM176381 A09 HIP CAT 1 1 Job Reference (optional) All Hour Trusses, Fort Pierce, FL 34946, design@aluuss.00m 6.00 12 5x10 Run: 1514 5x8 113x4 II 19 18 3x4 = 3.6 = 6x6 = 3x4 11 1.5x4 II 3.00 12 T 4x8 8x8= 7x8= 1.5x31N2 21-11.4 Sin 1 §10 11orHw 4s210 IM12 2 1140 214,11023,3-2 30<11 I 'Lof sae 4-10-14 09-0To3o a%s 7-zs Data 14114 Dead Load Defl. = 7116 in m Y �Jmm Plate Ottsets(X,)1- f4:0-3-00-3-01 f6:0-2-00-2-81 f9:0-1-14,Edgel f12:0-7-00-3-101 f14:0-1-120-2-01. f16:0-5-120441 LOADING(pso SPACING- 2-0-0 CSI. DEFL. in (too) Well L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.64 Vert(L-) -0.53 11-12 >861 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -1.03 11-12 >443 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.95 Horz(CT) 0.63 9 n/a n/a BCDL 10.0 Code FBC20177rP12014 Matrix -MS Weight:2341b FT=10% LUMBER - TOP CHORD 2x4 SP No.2'Except' T4,T5: 2x4 SP M 30 BOTCHORD 2x4 SP No.2 *Except* B2,B4: 2x4 SP No.3, 35: 2x4 SP M 30 WEBS 2x4 SP No.3 `Except' W5,W7: 2x4 SP No.2, W8: 2x4 SP M 30 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structuml wood sheathing directly applied or 2-8-6 oc pudins. BOTCHORD Rigid ceiling directly applied or 4-8-13 oc bracing. Except: 10.0-0 oc bracing: 16-18 WEBS 1 Row at midpt 5-14 2 Rows at 1/3 pts 6-14 MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 1491/0-7-10 (min. 0-1-12) 9 = 1485/0-7-10 (min. 0-1-11) Max Horz 2 = -142(LC 10) Max Uplift 2 = -346(LC 12) 9 = -349(LC 13) Max Grav 2 = 1491(LC 1) 9 = 1485(LC 1) FORCES. (lb) Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-2728/1635, 34=2684/1656, 4-5=-2044/1363, 5-5=178311297, 6-7=-3589/2235, 7-8=3752/2106, 8-9=4708/2721 BOTCHORD 2-19=1293/2385, 4-16=-256/571, 15-16=-1169/2366,15-30=-733fl782, 14-30=-733/1782, 7-12=-231/391, BOTCHORD 2-19=1293/2385, 4-16=-256/571, 15-16=1169/2366, 15-30=-733/1782, 14-30=-733/1782, 7-12=-231/391, 11-12=-2324/4260,9-11=-2320/4250 WEBS 3-19=263/256, 16-19=-1200/2207, 4-15=812/603, 5-15=-316/617, 6-14=3716/1603, 8-12=-879/776, 8-11=0/281, 6-12=-2586/5315, 12-14=1702/4204 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load noncmncurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0widewill fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except Qt--lb) 2=346, 9=349. LOAD CASES) Standard x �.,in,lutl ,gill ila]4 Rti3 .FIII1l W1'Jll ILLMSinIlNlbnSllYli I[f wr'W-.ieAsr la,.�rnmrti,InuRl arle¢eeq xx;--mlb L4.11.111tlLltl Yw LS Nn@r tlEtl 1410.^aq ulpu,c>.p¢e dax rw uo. is1 ppIq¢m0. ale rrywn,nmw rapt d r+. wy *I ev+surxn,aapw.i-.v.eemowsm ml tail T, ¢p +ev Anthony T. Tomb 111, P.E. m urci In * wlwh.- new p.o.ms.r..a a1 bldl+w s•• eml4 ¢ e p i MN ei 'i es :amcoam ran d mimeyaxgms Mnnmumxa.avEk r w.d a ' 80083 hM1hpango- rven re htarm®pUnempbb, I¢kleq(w smla 2YIMY hltlmvll Ma ,1w,Mfya mli,mitlemp�i'n i.lMndLL iNupr.l.nip,n+hle ml lr,Nzu.:ne 44515I. Lurie Blytl. f. iulAiMn Tb epem ^n9hAP'aiwa,LL M1ln1 n _ r9 YI+rFMi,!`+fi i ry+ fq d li'bq lagtlNY mm1 nIL Foit Fen.. R 349.6 pPi9 101EAI4dLrssn Ambryl.lnn5rIILN. Iep�uw aeltl slemunl,mpinn,np,rllnmrllvnMe rl nn pe runs rr4enA lPerllmul-/,tl�rnrl.Ie.Er61, l.L Job Truss cuss ype ty y RENAR MORNINGSIDE A0214418 VJRMSCM7763a1 A10 Hip SWclutal Gable 1 1 Job Reference (optional) C w-1 nanr t ruses, rorn rlerce, PL 49anb, aeslgn((yal Wse.oxn Run: 8.210 5 Mayy 182018 YnnI:8.21a s May 182018 MDek lndustdes, Inc. Tue Mar 5 14:29:15 2019 Pagge i ID:ld_00%yyT61Bi_TXoIlwHHzefvK-1 PRDJRScnA1 tEzDewubalGZjl hFJIrUChNwer uzdyfo r11-0 6-9.11 11-7-10 14012 20-11-10 23.11-4 29-11-5 WIT 9W hl-0 rr9-71 F 4-10.0 2-5.2 I 6-10.74 2-11-10 F fi-0-1 8611 1' -0-0' 6.00 12 5.6 = 3x4 = 5x6 = 22 21 _._ 3x8= 17-- 15 13 •. 3x6 = 4x4 = 2x4 11 106 14 1.5a4 11 5x8 it 3x6= 3.6= 3x4 = 23-1t1 Dead Load Defl. =1141n LOADING(psf) SPACING- 2-0-0 CST. DEFL. in (loc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.61 Vert(LL) 0.13 13-28 >768 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.98 Vert(CT) -0.6018-19 >467 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.47 Horz(CT) 0.01 11 n/a n/a BCDL 10.0 Code FBC20171TP12014 Martz -MS Weight:2201b FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 'Except' B2: 2x4 SP No-3 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-3-6 oc puriins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at micipt 7-18, 8-15 MiTek recommends that Stabilizers and required cross bracing be installed during Wss erection, in accordance with Stabilizer Installation ouide. REACTIONS. All bearings 14-11-10 except Qt=length) 2=0-7-10, 16=0-3-8. (Ib) - Max Herz 2=-126(LC 10) Max Uplift All uplift 100 lb or less atjoint(s) except 2=-268(LC 12), 15=205(LC 9), 13=-207(LC 13), 11=163(LC 13) Max Gmv All reactions 25016 or less atjoint(s) 16 except 2=920(LC 23), 15=1213(LC 1), 13=455(LC 24), 11=365(LC 24), 11=355(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-1447/1023, 3-4=-1135/916, 4-5=-1065/932, 5-6=-845/799, 6-7=-7307752, 7-8=43/372, 8-9=-52/358, 9-10=-60/337 BOTCHORD 2-22=719/1235, 5-20=-296/374, 19-20=-462{952,19-29=-149/412, 29-30=149/412, 18-30=-149/412 WEBS 20-22=-707/1118, 3-20=-3241315, 5-19=486/479, 7-19=-150/578, 7-18=-919/501, 15-1 8=-1 1091468, WEBS 20-22=-707/1118, 3-20=-324/315, 5-19=4861479, 7-19=-150/578, 7-18=-919/501, 15-18=-11091468, 8-18=301/105, 10-13=-2551396 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 5) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 268lb uplift at joint 2, 2051b uplift at joint 15, 207lb uplift at joint 13, 163 lb uplift at joint 11 and 163lb uplift at joint 11. LOAD CASE(S) Standard 04 nMq Wq h. x"+4 [ YL mmMq kMwy p* ,, Anthony TornM Ili, P.E. G80083 fv4kq F'n W( AVw4 M V41E)�[M1e. WI+Ya, dM Wt f 4Mb 1.11pJY,i111MV,1 HmN Imtlry8ni 11411M4 vlrltlNn tl4Lyuiege:mf Y>p LlnuW m,tlaMhm nn'., 4451 St Lucie Blvd W 4n(11 [Mkt Iqe _h RMrk^ N'41,upyp X 'I Idlg4 fM, I� Arq Ftl6q 1' yfd 4bn N ' JII. rpn P,nItP, ^L 36yC6 ( 'hl07016A I Aml6.... , Anne, 14aN AL rL I act.dal6c—,..,h,.,;,aA&6k4.dIt,.0m Fenaia In. A 1 hJ1..... AA,T.T.da III i.L Job + Truss I miss Type QtY Ply RENAR MORNINGSIDE Ap214419 IVRMSCM1763BI All Half Hip 1 1 Job Reference (optional) ny KDOI pusses, Fon Fierce, FL s4s4b, oemgnigalwss.mm nun: Sx6 4 1.5A 11 3x6 = Dead two Deb. = 1116 in 5 6 7 3x4 = T5x4 II 3.4 = 3x4 = 3x8 = 3x6 II LOADING(pst) SPACING- 2-M CSI. DEFL. in (loc) I/deb Ltd TCLL 20.0 Plate Grip DOL 1.25 TC 0-93 Vert(LL) 0.08 12-15 >999 360 TCDL 7.0 Lumber DOL 1.26 BC 0.50 Vert(CT) -0.13 12-15 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.81 Horz(CT) 0.03 8 n/a n/a BCDL 10.0 Code FBC2017/rPI2014 Matrix -MS LUMBER. TOP CHORD 2x4 SP No2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-4A oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 5A-3 oc bracing. WEBS 1 Row at midpl 4-9 MTek recommends that Stabilizers and required cross bracing be installed during buss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 8 = 95210-6-14 (min. 0-1-8) 2 = 93910-7-10 (min. 0-1-8) Max Horz 2 = 312(LC 11) Max Uplift 8 =-346(LC 9) 2 =-241(LC 12) Max Gmv 8 = 952(LC 1) 2 = 941(LC 23) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-1526/873, 34=9851640, 4-5=-597/507, 5-6=-597/507, 6-8=-904/684 BOTCHORD 2-12=113111310, 11-12=-113111310, 10-11=700/815, 9-10=-700/815 WEBS 3-12=0/272, 3-11=573/494, 4-11 =1 76/420, 4-9=-336/311, 5-9=-330/315, 6-9=6281909 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=42psf; BCDL=5.Opsf, h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS(envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water funding. 4) This tmss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This tmss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of buss to bearing plate capable of withstanding 346 lb uplift at joint 8 and 241 lb uplift at joint 2. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 142 lb FT=10% 1 x. q llnvA ndf u Igf nASUri[all} 41JIl MAIEAMIDISnflullnl•,'Mx! ftr I, III, k, N,Mn r4 M IAnnu1 r V1 yW[ HNW JT, lwal e,11195W uke Nn,mn natl Klp9 evY YlY vlkx N.!• Ib IYON .tl1. 4.Lm MTln+m fpaX,Ga+" vtlw Itl yreW nxpq tlmpi•umAweeal •y WJ%YmltyitlNs[rl ! NY elpp Ml.bIM 41tip fpmYtly Wh ' t ml tl'sYnk nl Yy- - ma. msma., No..',.n tl ptl ml.ir k.y,� K,mca' �Cm1.ImuN1.W{nl,.f ml lY.%n a xnwmmu a *-.+nYaynn aeon dkxyac m :p,r±.. a Anthony T�Tbmho R, P.E. NM<yupcgfm,es ,n.mlroarmrm+NN+�tlauay(srom m 1n(rytlnMFlx,tlVlrn,r4n,NNl,nEprm lrl f•.pni- .1n.nfel Nvp 1. pnpa,a^alt 4+a 4451 5I'le 61, 1. m,nmry xm y,N .mnl•,epmmn.i mlM�r .gmsml Nt>M. I I W^- <wYafn m,nmVf�m R.tl mi_ rT[led. Port Pierre,FL 34ee6 (rpynlelN10I6AIfeo,hesus hWi,LTid%ffl,PJ.Irp.noaer10n4oumn.nayimo,np,oihar4 UemdevnnuinwnmErylllaelLy+erbdtee.l.lmEelO, q. ,-v.. _.. -- __.. - X Job Truss Type Qty Ply RENAR MORNINGSIDE ^ A0214420 VVRMSCM1763BI Al2GE Half Hip Suplwlle4 1 1 Job Reference (optional) r. n-inwi imaaea, rwn rimrce, ru saaao, aesign�alwss.mm nun: 3x4 = 3x4 = 2.411 29 28 27 26 25 24 23 22 21 20 19 1a 1T 3x4 = 3x4 = 3.4 = 2x4 II LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/defl Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.50 Ved(LL) -0.01 16 n/r 90 TCDL 7.0 Lumber DOL 1.25 BC 0.14 Ved(CT) -0.01 15-16 n/r 80 BCLL 0.0 ' Rep Stress Incr YES WB 0.07 Horz(CT) -0.00 17 n/a n/a BCDL 10.0 Code FBC2017TFP12014 Matrix-S Wind(L-) 0.00 16 n/r 120 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: 10-0-0 oc bracing: 2-29,28-29,27-28. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. All bearings 23-7-4. (Ib) - Max Hoa 2= 277(LC 11) Max Uplift, All uplift 100 lb or less at joint(s) 2, 24, 25, 26, 29, 23, 21, 20, 19. 18 except 17=-130(LC 9), 27=-118(LC 12) Max Grav All reactions 250 lb or less at joint(s) 17, 2, 24, 25, 26, 27, 28, 29, 23, 21, 20, 19, 18 FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-345/193, 3-4=-282/171, 4-5=-305/184 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1. 4) Provide adequate drainage to prevent water ponding. 5) All plates are 1.5x4 MT20 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 9)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 10016 uplift at joint(s) 2, 24, 25, 26, 29, 23, 21, 20. 19, 18 except Qt=1b) 17=130. 27=118. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 164 Ib FT = 10% ! .q rvmx.«p4 ne i I nml s rya 1 t r[ avrat grE rCl'll jty Hkrry xmxupp «t.ae « i w:lp ln^rIIPVC;w x3e,/rl,Y,¢I Jd IadYn uxua«� u xd MI"'A X v.1�arMaM Wvk *x -IsaJ I Cr tr« xnn.hg.xe4d+n' tx ^�arwva rgn.q� XYrdexdyauwa xsra sWx..d Rtix +rMNaar ue4n Aathxyv T. Tomhe li',PE M Y Iln Ikly Y .z ah C• C .n iC e.4dq .fw e6 Nv.tl It(nia4eJ .Yq M 9A Nv Id41"A «is(tr ml n:wHyMpy ax ett' Y{¢ll,nnl kllkn 'Yla RNq trues I(¢ri lA i,IM ^r1E MMFm fi.eemrd ALLgf ptl&IIM T.{pYWll Xu1 W1 f4.ryrJl+ P41xbn3 d.nWl+n,lYNnh.y�,uwlxp qnn M,nrWAr «.er, eoe93 M rMsIF f JrpMw tig! Ih I'e-rmk 4rw Ut6,I N.10. 4iR.lye I hYry iAyRY!& rsu ,Mvv Fi ar515C Leppigba7616Atievl Lvaes .r , , Fort Pierce, FL 34o4 x tom1.vabvXlRE Job a Truss Truss Type ty y RENAR MORNINGSIDE A0274427 OJRMSCM1763BI B01G Half Hip Girder 1 1 Job Reference o llonal Ahl Roof Trusses, Fort Pierce, FL 34946. design@a l lruss.wm Run: 3x4 = 1=4 11 3x4 = LOADING(psf) SPACING- 2-M CSI. DEFL. in (fee) Well Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.09 6-9 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.61 Ved(CT) -0.14 6-9 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.75 Horz(CT) 0.02 5 n/a n/a BCDL 10.0 Code FBC201771'PI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural woad sheathing directly applied or4-3-10 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 0-9-13 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during buss erection, in accordance with Stabilizer Installation euide. REACTIONS. (lb/size) 2 = 784/0-7-10 (min. 0-1-8) 5 = 109610-3-10 (min.0-1-8) Max Horz 2 = 166(LC 8) Max Uplift 2 -237(LC 8) 5 = -323(LC 5) Max Grav 2 = 784(LC 1) 5 = 1096(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces =(Ib) or less except when shown. TOPCHORD 2-3=-1131/309,4-5=-312/175 BOTCHORD 2-6=-331/945, 6-12=330/968, 12-13=-330/968, 5-13=-330/968 WEBS 3-6=0/678, 3-5=-11511397 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) except at --lb) 2=237, 5=323. 7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 223 lb down and 237111 up at 7-0-0, and 110111 down and 122 lb up at 9-0-12, and 155 lb down and 1021b up at 11-0-12on top chord, and 345 Ib down and 64 lb up at 7-0-0, and 861b down at 9-0-12, and 100 lb down at 11-0-12 on bottomthord. The design/selection of such connection device(s) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plo Vert: 1-3=-54, 34=-54, 5-7=-20 Concentrated Loads (lb)" Vert: 6=-345(F) 3=176(F) 10=11 O(F) 11=155(F) 12=65(F) 13=-77(F) Dead Loan! Defl. =1116 in PLATES GRIP MT20 2441190 Weight: 57 lb FT=10k mwxnrn - ra�nxxY nr uvngYt9�'l '1 v\nmRYxl .HevmvmYnxmP \�dt?v'rvIR9P10A%\rAMFFRt�y'YxpIWRI. lh Y. pFinM'u Ya1MCbeyAv9y Anthony T. Tnmhn III, V.E. efYud4tl'n5 MY-Iiereyneolmtlp AM bP•ns�mNtFfeY4M4Mpx h'xind4lP.itT.vlRIud4YgMeat Bl.figpm uhypxlwkNYw Jb,1 nrbL9larpprq-o,b.YmvIhR9Jflta ReuWntl =80003 h HYq M{e MfwTYr.vn MYtYMIWNhrmnvl Mlut Jb:4691gaJ W!Ynw;INPdrSl11I9YlIPImMs.Nk FRdPJs. 1RIR'atm:tggitatmf lmsCblrutpvyr.l:euktPLmnvllMt lvdY>v.ntt St. Lucie Blvd. t5um IdadlYr Laxmtl.m\m�ghtlllYlPwd,LL neb•,h�ml9o-erMlntl441:rm.xlrcsflm Egm�dnrMlM am�YieamnitlNbllll. For[ort P pierce, FL 349e6 (epyip611D7016AIfeel4eus-W6vyl.ionEe III,71_¢cpin/eniouhF'udemrRnl,lnmtle�m, hpmliEhcd.riOom Mr vNlev pemissiouhvmhl laolLnsesxlu6o�.7.Gtrdulh,PS_ _.. _ _...-._. - _ _ ._ ._.. ,. Job Truss muss Type CRY RENAR MORNINGSIDE n A0214422 MMSCM1763BI B02 Half Hip jPly 1 1 Job Reference (optional) 1. A-1 Hoof I NSSes, Fort Plerce, FL 34946, dasign@auruss.con1 Run: 8210 5 Mayy 18 2018 Pant: 8.210 s Ma yy 18 2018 Moral, Industries. Inc. Tue Mar 514:29:18 2019 Page 1 ID:Id_00XyyT61Bi_TXoljwHHzetvK-R 7LxTUV45PS5RyDb19HMuBFquKOwFneNL8GQOzdyfl -1d-0 9-0-0 12-0-0 1-4-0 I 9-0-0 5x8 � 1.5x4 11 4x4 = 1.5x4 II 6x6 = Dead Load Deft. = W16 in LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Ved(LL) 0.25 6-9 >567 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Ved(CT) -0.36 6-9 >397 240 BCLL 0.0 Rep Stress liner YES WB 0.31 Horz(CT) 0.01 2 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 60 Ib FT = 10 LUMBER - TOP CHORD 2x4 SP M 30 `Except` T2: 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0A oc puffins, except end verticals. BOTCHORD Rigid ceiling directly applied or 7-6-4 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 2 = 519/0-7-10 (min. 0-1-8) 5 = 43410-3-10 (min. 0-1-8) Max Horz 2 = 207(LC 12) Max Uplift 2 = -128(LC 12) 5 = -128(LC 12) Max Grav 2 = 519(LC 1) 5 = 434(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-426/140 BOTCHORD 2-6=-261/294, 5.6=-262/302 WEBS 3-6=-34/365, 3-5=-580/505 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extenor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joings) except at —lb) 2=128, 5=128. LOAD CASES) Standard r n r�m,a4r a f� a; ur�(,[wr{ax+u muuamtntmxa.i atr� a -wtr 1. twrturw••smw�mw�.n t. n1 m nitm:.rmrn rtt nnmEu L - ok,�,n,� o d m ns y rr ,nrn fse ax tT.Ilf omtmap f a y a mv. na4 +p.a�Impa a.dA ntmt as is mf fan uit front mlamwtm tnt ap +r• m.lp umdin Anthony T. Tombo 117, P.E. .a a m+1.nxlm m.,av^a o me ..... a sa t.. a+r ,caemm ma.wwm m !qw WI'oar Iamnp a aaf out .+bwwv4 .,I. ulm+rn {Jak ya = a0083 mr 1a�.,rmein n r mlroaupma fw uahr�rxt+«o,.m.uvrxniehmwau d armeN . mta: f• p..un, ra.wr l.mmuyntmlesl,o)en •!t ,a,.n+e:m.a, mJS,Ayrtmm�mwo+mml.xl into 4 9mt a {& . t rm.4�x x roams Wass d ld+aalru. 4451 tune bled. FOR Pierrrn ce, FL b9<6 Lppipo14g01EA Ile<II ors WJorrl. tea5rlll,Pf rrpumn oedlmvdvrvoen, nvsyloihnpml pneda t6sNWa+�napnmhs eel emAlroolLesut AelAonrLLml4III, Pl. Job Truss Fruss I ype RENAR MORNINGSIDE IJRMSCM176381 B03 Monopitch jQly 2 1 A0214423 Job Reference (optional) .n:nw: uumea, rmh rren.e, �,»nrm, aesign m�a,wss.wm LOADING(psf) SPACING- 2-M TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2017/rP12014 LUMBER - TOP CHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 8-2-7 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 2 = 519/0-7-10 (min. 0-1-8) 5 = 434/0-3-10 (min. 0-1-8) Max Horz 2 = 264(LC 12) Max Uplift 2 =-107(LC 12) 5 =-191(LC 12) Max Grav 2 = 519(LC 1) 5 = 434(LC 1) FORCES. (to) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. TOPCHORD 2-3=-599/184 BOTCHORD 2-6=-470/484, 5-6=470/484 WEBS 3-6=0/274, 3-5=-552/535 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl.. GCpi=0.18; MWFRS (envelope) and C-C Extenor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces :3 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 lost bottom chord live load noncon current with any other live loads. I... Iu8 Mar J l9:Le:l`J LUlu 1.5x4 If 4 3x4 = 1.5x4 II 44 = CSI. DEFL in (loc) I/deft L/d PLATES GRIP TC 0.46 Vert(L-) 0.06 6-9 >999 360 MT20 244/190 BC 0.37 Ved(CT) -0.08 6-9 >999 240 WB 0.43 Horz(CT) 0.01 5 n/a n/a Matrix -MS Weight: 621b FT=10% 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 Ib uplift at joint(s) except (jt=lb) 2=107, 5=191. LOAD CASE(S) Standard J I AvvllmrznAvhveyL7vmhe10, F1, pepmlv4romdnielaena6ivmrlmm,itpr•AipAe:IvilEevinu,inmpnmivJwLen NivelLnsu-AdSvvyLLmlv10, P.L '"n N••p'twgam.:rmman meaa,..hm:gwFg2mh.v4+.d I:m O,+pi,m,.nussrra:+u..e.: Anthony T. Tombo 111, P.E. s 90083 "51.51'bxie Blvd. • -- rot p'.ehce, FL 34946 Job I was I mss Type ty y RENAR MORNINGSIDE ^ A0214424 WRMSCM1763111 COtG Hip Girder 1 1 Joh Reference o Bonet A-1 Roof Trusses, Fort Pierce, FL 34946, design@aitrues.com Run: 8210 s May 18 2018 Print 8,210 s May 18 2018 MTek Industries, Inc. Tue Mar 514.29:19 2019 Page i ID:Id_OOXyyT61Bi TXoljwHHzetvK-vAhk9pV7rOXJibXP9kgWv6kMQlc2fignc_upygzdyfk -1-4-0 7-0-0 124-0 19-0-0 1-4-0 I 7-M 5-4-0I &-" ' I 4x8 = 3x4 = 1.5x4 II 4%0 3x4 = 46 = LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Well L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) -0.11 6-8 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.99 Vert(CT) -0.21 6-8 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.26 Hoa(CT) 0.08 5 n/a me BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS LUMBER - TOP CHORD 2x4 SP M 30'Except' T3: 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-9-9 oc puriins. BOTCHORD Rigid ceiling directly applied or 6-10-7 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 5 = 1431/0-3-10 (min. 0-1-11) 2 = 1477/0-7-10 (min.0-1-12) Max Horz 2 = 80(LC 8) Max Uplift 5 = -438(LC 9) 2 = 467(LC 8) Max Grav 5 = 1431(LC 1) 2 = 1477(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-3=-2659/819, 3-15=-22857765, 15-16=-22857765, 4-16=-22857765, 4-5=2622/802 BOTCHORD 2-8=-701/2310, 8-17=-700/2334, 7-17=-700/2334, 7-18=-700/2334, 6-18=-700/2334, 5-6=-643/2263 WEBS 3-8=0/679,4-6=0/658 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed fora 10.0 lost bottom chord live load nonconcurrentwith any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bott"r,hord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at=lb) 5=438, 2=467. 7) Hanger(s) or other connection deviea(s)shalf b;i,7 — provided sufficient to support concentrated load(s) 223 lb down and 237 Ib up at 7-0-0, 110 Ib down and 122 lb up at 9-0-12, and 1101b down and 122 lb up at 10-34, and 261 lb down and 258 lb up at 124-0 on top chord, and 345 lb down and 64 Ib up at 7-M, 86 lb down at 9-0-12, and 86 lb down at 10-34, and 342 lb down and 41 lb up at 12-34 on bottom chord. The design/selection of such connection deAce(6) is the responsibility of others. 8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead t Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (pit) Ven: 1-3=-54, 3-0=-54, 4-5=-54, 9-12=-20 Concentrated Loads (Ib) Vert: 3=-176(B)4=-214(B)8=-345(6)6=-342(B) 15=-110(B) 16=-110(13)17=-65(e) 18=-65(B) e0. =118 In PLATES GRIP MT20 244/190 Weight: 81 lb FT=10% eiq Nrt Ott h nW, Tri0funnl WOUInLilY.ill'ffnlllxlT'mcr iurW Itgw w w,eA.m t.4y!t",!PG heNll. MM1krl ltl 9 4. Id pbv aaa dertn xI'te.mn .s x4, mo ad.l ors (pe.9 .mbo„yl, a vlmmr dhra .el atry. e,ml huftl try1tl mmoary=[Z e1T T IN ,=I', Archery i. Tm.to 111, P.E. N udWFY IN .p m.dhN hf „awl, III Ou l'a hM-nlRll`h 4NhNdi '3 ,I slIM.}♦ 'a T4i Aetl rid .Nrt91#A 9' 0 WY mIJdMh M.iY.irtlI =80083 hl Sy Jlgv frtM Y blWM pyat 4lhnfvPMY,ghY Nli11N1IInd W1 �! efbrxr i' 1rIkM1aC mpnM lb.lt!m,I „uww,l.ef &IgOpMoll l[Y+d,a�vfi 4451 St. Luc?MA. x lulewl a r a n yhalin p ,1`1 . upnHMf I6 _ !q r Iwt, oa,na Irt J llll Fort Pierce, FL M946 � L IIBYW641teo18assrs�Aidve Llem6rllh Pi Pe artedenlvmemr.4 emv ime, l6ned.nbevlbe ranee a,mnmvhmAlleelLnm Adea.LbmtmllhlJ. PNiI Y Per. Y -po p Job Tmss Truss Type QVY RENAR MORNINGSIDE %RMSCM1763131 CO2 Hip jPly 1 1 A0214425 Job Reference (optional) Aid Roof Trusses, red Pierce. FL 34946, desigr@allruss.com 4.6 i 4x6 3x4 i 4x6 = 46 = 1.5x4 II 1.5x4 II LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES TCLL 20.0 Plate Grip DOL 1.26 TC 0.99 Vert(LL) -0.27 8-14 >846 360 MT20 TCDL 7.0 Lumber DOL 1.25 BC 0.77 Vert(CT) -0.48 8-14 >477 240 BCLL 0.0 ' Rep Stress Inter YES WB 0.10 Horz(CT) 0.02 5 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix -MS Weight: 76 lb LUMBER - TOP CHORD 2x4 SP No.2'Except' T1: 2x4 SP M 30 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Right: 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied. BOTCHORD Rigid ceiling directly applied or 7-1-7 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 5 = 700/0-3-10 (min. 0-1-8) 2 = 781/0-7-10 (min. 0-1-8) Max Hors 2 = 95(LC 12) Max Uplift 5 = -161(LC 13) 2 = -200(LC 12) Max Grev 5 = 700(LC 1) 2 = 781(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. TOP CHORD 2-3=-1005/600, 3-4=-815/657, 4-5=-1011/603 BOTCHORD 2-8=-376/811, 7-8=-3761815, 6-7=-3761815, 5-6=-376/810 WEBS 4-6=-351265 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=130; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been dosignad for at0.0.psf bottom chord live load nonwricurrent with any other live loads. 5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1O0 lb uplift at joint(s) except ot--Ih) 5=161, 2=200. LOAD CASE(S) Standard Dead Load Deft. = 3/16 in GRIP 244/19D FT=10% I�s. Irvr.n. qtl muo[n�,>7F,p n1lpn'.nlnmaYttalrllm�elftrl"+-nr ,mrw.tvryu:pp.roumetlrM.xnq I-p,•�pr.a1'nmmwrtl un]Lm uu' otl ruM m+eco: YI' an.x:wr pmmla Mtl1 m:m I v{ a p.mn ...... nmmYn:mtlr.,.v: ry 11^raml-m .L1 Ayml e,mo.h,a lM1l -mcn p. Irst waxy Anthon; T. Tombo 111, P.E. N tl1 r:nt'r qWq" m rk !mJ NP b I LLykp 'a HUIX.4 Se1m451.Yq W.fntl M1 qY -tl' BCM 1rt11 imi i�ltlryla4q I I:YM nlhmSf r.*v a a 80083 — IIL I a Il wx u. c r rmrw . ..Irr� �eeyrr.mvmm-.m. aslavnlpmmuun,me.ma ra p•r .. nl ' :.:I..:'>• lr�rveul ny.v.l.mutq, [qa:r n ua , 4451 SL Lu.le Blvd. f •uNNI( rme � •Fblen 1.1 •Inf & ILImbfi3 1 ryR Inxtolr':1q ImmlleNY !3tl 1!H_ axa � Fod Pierce, FL 349<fi (eppirElD ]OID 41 Enlinun AmpvvpLlvmpvlll P.1 IeprW.n v irlmmmm,uvgfma tprd Ened.nslmlbe.rinevpemm v6emAlledLesses-AmtM1vnri.remlvlryl.L - Job I russ muss ype ty y REtJAR MORNINGSIOE ` A0214426 WRMSCM1763BI CO3 Common 1 1 Job Reference o tional � nun: 4x4 = 4 514:29:21 2019 Page 1 6L97dC431NvAYzdyfi Dead toad Den. = 3/16 In 6.00 r 12 1.5x4 1.5x4 9 3 5 1 1 b Bi 4x4 = 5x8 = 4.4 = LOADING(psf) SPACING- 2-0-0 CSL DEFL. in (loc) Well L/d TCLL 20.0 Plate Grip DOL 1.25 TC OA5 Vert(LL) -0.14 7-13 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.30 7-13 >750 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.20 Hom(CT) 0.03 6 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matdx-MS LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 5-0-13 oc pudins. BOT CHORD Rigid ceiling directly applied or 7-5-7 oc bracing. _SMiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installafino guide. REACTIONS. (lb/size) 6 = 700/0-3-10 (min.0-1-8) 2 = 781/0-7-10 (min. 0-1-8) Max Horz 2 = 99(LC 12) Max Uplift 6 = -165(LC 13) 2 = -204(LC 12) Max Grav 6 = 700(LC 1) 2 = 781(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except whenshown. TOPCHORD 2-3=11581777, 3A=-873/579, 4-5=-869/577, 5-6=-1142f764 BOTCHORD 2-7=-612/1014, 6-7=-594/977 WEBS 4-7=-269/531, 5-7=-308/363, 3-7=-3431383 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) except Qt=lb) 6=165, 2=204. LOAD CASE(S) Standard PLATES MT20 GRIP 244/190 Weight: 84 lb FT=10% x'9krPtl qY R11nCa dT93(¢YII}QIl;R[IISr(Allnffplydll m0'1ui .Pfr'p. rllbv}N Mrtyb• 1 Q pnq 11 -.iy45p/I y4ftttlA 31nF[i. W Wd ItJ' GI' inl''n rth IM@n 1 k dll letip p i +clam, Inver` t'a, IOe r psedYPM rrrnN4ryyY1 Xf i Ih'1 Pe1W �.,�IM.1 p uPr bp]mew tl I J avuin3L ryYYq yurAJertlPA MO tlIMMWyOuq n9dIa1G rK WA, bM M Mtlq dh.04w1ntr11 tlP1 Mygla}'R- nNlm�1f*. �'BDn}''. TD^Y..')i, D.E. MI MapM�Wfx-M1 SXw�MIhM Pn+dgdd dP 4JMgl to fe llm ron RYIrII WhIPWN[I 'M ApN pl Tlkhx.t Pyeaefm nfYilrnlhvw,l.RSFfy�J¢nP11n1NnX+-^s:..: `BBBB n. u1dn01 wm 7rd .emlha rm ,^argil Neln, - n Ilmm Id,1h 1. re EPY rbX+�nw'-ia.lr ralmltr+dnlhl 44515[ Lu Bivd. • cart Nielre, R 3494h 6,4,h02N6A IW1...eu-Anbertlemhelil Pt pepndedmeeldl/Drumm ma ll ,rspredhnrd.dlmhe nneepmm�mlheoki leolLexn AeSvorl.IeMe10, p.f. Job � Nss Nay ype ly y RENAR MORNINGSIDE A021442] VlRMSCMI]6381 C04 Half Hip 1 1 J h R 1 Ce ( pC0 all Ail Knpl I n6SeS, ran P eioe, FL 34945, de519n(mal Wss.LOm Run: 6.210 s May 16 2U18 GnnC 6.210 s May to 2018 MTek IntlusVies, Inc. Tue Mar 514:29:21 2019 Pagel ID:Id_OOXyyT61Bi_TXoljwHHzefvK-sZoUaV WNNOnlyugoH9i_Xphl6J77T6431Nw1YzdyrI -1-4-0 5-94 11-M 19-0-0 7-4-0 6-9-4 5-2-12 843-0 r 4x6 = 3.6 = 4 5 Dead Load D.O. = 5116 in LOADING(psf) SPACING- 2-0-0 CSI. DEFL. it (loc) I/dell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.85 Vert(LL) -0.27 7-10 >840 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.95 Vert(CT) -0.56 7-10 >404 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.85 Horz(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 99 lb FT = 10 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-2-0 oc purins, except end verticals. BOTCHORD Rigid ceiling directly applied or 2-2-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during buss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 6 = 69510-3-10 (min. 0-1-8) 2 = 776/0-7-10 (min_ 0-1-8) Max Horz 2 = 247(LC 12) Max Uplift 6 = -197(LC 9) 2 = -188(LC 12) Max Grew 6 = 695(LC 1) 2 = 776(LC 1) FORCES. (lb) Max. Comp./Max, Ten. - All forces 250 (lb) or less except when shown. - TOPCHORD 2-3=-11031624, 3-4=-774/392, 4-5=-631 /427, 5-6=-636/485 BOTCHORD 2-7=-811/963 WEBS 3-7=-376/434, 5-7= 499f738 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 lost bottom chord live load nonconcurrent with any other live loads. 5)"This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.Opsf. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except 61=1b) 6=197, 2=188. LOAD CASE(S) Standard pxrmiaioll Aom A -I YuotLeumd 0... L4.brilij.f. Arthony T. Tomha ll, P.E. = SOC63 4451 St. Lucie 81cd. Fort Pierce, FL 34946 Job I ruse I ruse I ype lY y RENAR MORNINGSIDE A0214428 WRMSCM1763B1 CJ1 Comer Jack 6 1 Job Reference (optional);. A-1 Roof Trusses, Fort Pierce, FL 34946, design@al Luss.com Ran: 8,210s MaY l8 2018 Print: 8.210 s May 18 2018 MiTek Industries, Inc. Tue Mar 5 14:29:22 2019 Page 1 ID:Id_OOXyyT61Bi_TXoljwHHzetvK-KlMsngX?aJv 72F_gsDDXkM1?Wtks7bEly6T7i zdyfh -14-0 F• 0.1111 1-0-0 0-11-11 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Well Ud TCLL 20.0 Plate Grip DOL 1.25 TIC0.18 Ved(LL) 0.00 7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.03 Vert(CT) 0.00 7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 4 We n/a BCDL 10.0 Code FBC2017/rP12014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 0-11-11 oc puriins. BOTCHORD Rigid ceiling directly applied or 10-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = -3/Mechanical 2 = 166/0-M (min. 0-1-8) 4 = -16/Mechanical Max Horz 2 = 42(LC 12) Max Uplift 3 = -3(LC 1) 2 = -70(LC 12) 4 = -16(LC 1) Max Grav 3 . = 12(LC 8) 2 = 166(LC 1) 4 = 20(LC 8) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vul1=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. If; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s)3, 2, 4. LOAD CASE(S) Standard PLATES GRIP MT20 2441190 Weight: 6lb FT = 10% A[.q RUM'Y( ,IorR-M1Ftlin&.44 RM,(cm,ce IOU klli Yr rraA-I le46pp al frdn %milmis kplh ,1kw'. Ik tM(1.I IE'It1An LN. .EtlntH tlntl T0,1 ql .' ItlN IL hRlwNtltll M91,e15}c X4 RPrtpeun tlpM brtl 4.xq ya dtlli'*'ble{. e:du}11j.I dFAyAN IRLblp vop bga tnvin -6y Anthony T. Tombo 111, P 1. A vddrl, 4 pl♦W Y '.urbkj Ai..'h .YO ♦ ,1 M h a'tlFhIL'. � S•,tl WI !♦IM sl rRl l Wl dY NW kll Ad_ trJti9lY+lrn'4 mlid vIM J[Yh 4vti d 180083 al.Ygnite tmam i .r:,[ eellm vmv .+ rr Iwwey V rr yyl.w slk lnravu rA lapitp4 Ira d y+�.. sfa eYun duo^.I.nl4rporen n ++++re:r,.i.: 44515t. Luce Blvd. r1 ♦IUTA♦01( pPW ¢M mql tll4n f Ihl ul 1 t A I IT"A" t YMf9 W7nvdkm NuH 1111 (d hI020]1 A I Iedlanes AnlarY711 ne 111J.1.re N o e lHn gonna Port Pierze, FL 349tl6 pprqp ginh ,poFebedrlHon He rnnmpnni M1 A -I llonrasrAedonpi lrmtolil, P.(. Job Truss was ype ly y RENAR MORNINGSIDE SIRMSCM176381 CA Camer Jack 5 1 A0214429 Job Reference (optional) n, maul rmsses, ron rierce, rL aq , aesign(jalwss.com 1 3s, Inc. Tue Mar 514:29:22 2019 Page 1 -_gsDDXkM 1? W sRs7bEly6TZ_zrlyfh Plate Offsets (X,Y)— 12:OA-0,0-0-41 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) I/deft Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.18 Vert(LL) 0.01 4-7 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.12 Vert(CT) -0.01 4-7 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 12 lb FT = 10 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-11-11 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 60/Mechanical 2 = 201/0-8-0 (min.0-1-8) 4 = 30/Mechanical Max Horz 2 = 82(LC 12) Max Uplift 3 = -43(LC 12) 2 = -72(LC 8) 4 = -27(LC 9) Max Grav 3 = 60(1-C 1) 2 = 201(LC 1) 4 = 49(LC 3) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) WihC: ASCE 7-10; Vulf=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left exposed; porch left exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at jclnt(s)3, 2,4. LOAD CASE(S) Standard p q hrvlNngY m11 kL RdS6j*91rllYlll{IIWrl9Pll[Ylnmx'U:l t:nr m' I+INJppnemW NwN. I. Ory+e q'P �dhlMII.1 I+NILIa+ a Nh. Ytl u4 MY mmP y WI'u+9rlA YfY tl4h10J Nll+l „i4o4l+Mxr1 Ip MI Y Megltl.p p.fpMpPWWlgsn'u9rtyM00(pglni ,1 f}d+bl[,1 M.M IgI.IYLM+Vru.i@] L =+ntl6i Anthony T. Tombo 111, P.E. y tlmv1..X t r. hcp,xN.tlrvl..r mo.mmmNgf AI.uy Mq m h a.rerl.n.vAm.f lxt'hgpr EN&IOR.NmkN Wert mWlbiq q emiln h.yN1. qm ' %300a3 a l.v:lln:r rxaa..:- :,r+..artmw.pwrmpgv 11Wagfrq Lbrlm mr.pey+gln+Nuamm.m.fnrp.,Nplga Rl N.a.a•rp�.+a .tam ra•r. 1. ImrPri.rneMlm. r,N.rY..;v 4451 EI. lode Blvd: rtx.ulaMlt RmyeN-r�g1ltlllwrnrhN INlmr (qml- [IpIY 1[r L 4v Fy ntsi Nfq NgaaNtmvmlNNbIPH Fort Pierce, FL 34946 p(rpri+bD1PI6F1faoRnsses-ktleeri.lomEe Yl 1.[Pip In rehP Jer ml,magle,syollYed nlennemnee Pneftim4w41leoliului l@n.,Lleedalll,hl. Job 11as I was I ype Qty Ply RENAR MORNINGSIDE ' A0214430 WRMSCM1763BI CJ3A Comer Jack 1 1 Job Reference (optional) n, nwi uua a. Nn nerve, re,» , oesign[Nawuss.com 1<un: alloy may lazma vanr.a,us may iuzm a mnex lnaustaes. mc. we mar a 1429232019 Paggel ID:Id_OOXyyT61Bi_TXo1jwHHzefvKaxwE_AYdvdl IBCgAOakS3xuCuvCsbarN Wmi 5.Rzdyfg 2-7-9 279 3x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.17 Vad(LL) -0.00 3-6 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.11 Ved(CT) -0.01 3-6 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) 0.00 1 n/a n/a SCOL 10.0 Code FBC2017rTP12014 Matrix -MP Weight: 9Ib FT = 10 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 2-7-9 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. - Mi7ekgecommends that Stabilizers and required cross Sratlng be installed during truss erection, in accordance with Stabilizer Installationguide. REACTIONS. (lb/size) 1 = 136/0-M (min. 0-1-8) 2 = 88/Mechanical 3 = 42/Mechanical Max Horz 1 = 52(LC 12) Max Uplift 2"—= -31(LC 12) Max Grav 1 = 136(LC 1) 2 = 88(LC 1) 3 = 56(LC 3) FORCES. (lb) Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10: Vu1t=160mph (3-second gust) Vasd=124mph; TCDL=4:2psf;.5CDL=5jQp5,,T; h=13Il; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exlenor(2) zone; cantilever left and right exposed ; end ver ical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 36.0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to hearing plate capable of withstanding 100 lb uplift at joint(s) 2. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=l-25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=54, 34=-20 Concentrated Loads (lb) Vert, 7=75 mw rama...11n >x 1ur art3f;wa arut.r lasm[Prmm[at hlxm,Ampr ,,.e-w Ire, r.w++ .anyun. i Ina �ly.'ee,YYmttt 1 rLN sr , - pa w dd nrsn ml ,.ear Man•[4mrA -mtr i pey t. t rc5tlry4p rymssn gloo r n ra ra ha mry.w lryLA qk 3 Iy M1a mtoo �W IerL -4itin p briar "I n! Anthony T. Toniba;ll, C.E. ea ndk�in Mgdagkd q•-M imtlnp P ,wyCk ga hdayq me h�amul. tl Im Mai a.3J m19T let Wa wi tl6i c.Ymglstq�ay nn !h ilalbm yr '...tl hAx,pwrn am^ a mrro„1 r wnlaa do kuxgr lad+dm a.,w.uvl m 3I14 dmd m- amr IN via' ,yen„m:admsda•tmmm:.lmw,m.,aan.lhuwa+..au = 80033 Aeeh,Itl�Wll Lam tl - mgl3tllwins.neL Nims epxublLlddfe3 Wrm 1 f3n Fye ,'sway 1pei=e-TM Idtl Ini 445I St. Lucie Blvd. • Fort Pierre, R 34W6 6ppi9dl®]01l AI Fel6eva Aellpey Lfemde lll,Pf PgmGa,vepin lAumm,ueglereyrsp d3netl.ndamae.nlxe pembwel emAlleolLnus-km•.f.Iemd401,r 1. Truss I was I ype UtY P1Y RENAR MORNINGSIDE A0214431 `hRM5CMt763a1 Cis Ccmer Jah 5 t Job Reference (optional) 1 moo, I msses, ran rlerce, VL . rr o. aesgnuaivuss.com 6 1 2x4 = 514:29:23 2019 Page 1 3wbarNWcs15Rzdyfg LOADING(psf) SPACING- 2-M CSI. DEFL in (loc) I/deb Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) 0.04 4-7 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.29 Vert(CT) -0.05 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 nla n/a BCDL 10.0 Code FBC2017rfP12014 Matrix -MP Weight: 18 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No-2 BOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 4-11-11 oc puriins. BOT CHORD Rigid ceiling directly applied or 10-M oc bracing. MTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 112/Mechanical 2 = 26810-7-10 (min.0-1-8) . 4 = 59/Mechanical Max Horz 2 = 123(LC 12) Max Uplift 3 = -80(LC 12) 2 = -69(LC 12) Max Grav 3 = 1121LC 1) 2 = 268(LC 1) 4 = 88(LC 3) FORCES. (lb) Max. Camp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.6(l 2) This truss has been designed for a 10.0 fist bottom chord live load nonconcurrent with any other live loads. 3)' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-&0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. 4 q ltrc.eNgH hllnl nSil jdlllllVH4IIIN{II IXIICI}Itl3ik Ml'J111[r3raatlfRNv, lrAtYVAl.udmWndulpnlYl iq+L ryilb',Wlkel(s tl.I bry 11M PF' Wennrn tlW ICPry 4i arf9k IdF Wm91NIM tltl 1 R91p n tN'WI M1 J oIPJ. FnMt paativld'u4vltgte %,ywWryb Rl p Mtrfl LYJ bll-0Nr delRl hL,ry+ wpan,W Intl�Mf Anthony T. Tembo 111,PE. M tln�l;.s 5 kN a F,.d4ndhp hp , d }d MMI .Gy d+mltla N,LSnln. brtll+Yx1M<wflFi q 9P da'90Nv.ma H ...Lsq!#qnm -MMe tlh gndY,n uM.fntl a 90083 MMY 1M,9x LtTa.L ItWM hIGAN'r.W Vrlm is InVy(wlum'inb.mw IWwMil.f%Inq VflmNaev:k i,eidplx.. Plkin.YmFak M[Potd4Lnf %up.lntPn9+uP uif k,.K.t,. w: 4d515t.Lucle Blvd. f uWdll CMtl petl M.yl ,NK rl fnln S F lal 1 1. 14 F9 �u dwlnVA Cknlb WNw Itld" VII_ T° Fort Pierce. FL 34946 bpplrel®1OIdA I F.•t49sses-Mlaerl.lwAe06i f. Lp oltla 9kkh1 U �nwl nounµ .mW In1E ntl0em6e 9riva Armin wbe%11 Peullrnsn Aodu, l r mhn4r.1. Job Truss I mss L ype Qty Ply RENAR MORNINGSIDE A0214432 WRMSCM176381 CJSA Comer Jark 1 i Job Reference (optional) A-1 Roof Trusses, FOM Pierce, FL 34946, desgn@altruss.com Run: 8210 s May 18 2018 Point: 8.210 s May 18 2018 MTek Industries, Inc. Tue Mar 514:29.24 2019 Pagel ID:Id_0OXyyT61Bi_TXo1jwHHzefV GBUdCWYGgxAcpMPNyHGhc9RJIJUKK15WlGbaetzdyff 3.4 = 4-7-9 4-7-9 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deg L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.42 Vert(L-) 0.04 3-6 >999 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.35 Vert(CT) -0.05 3-6 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.00 Horz(CT) -0.01 2 n/a We BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 15 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 4-7-9 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 202/0-3-8 (min. 0-1-8) 2 = 119/Mechanical 3 = 62/Mechanical- Max Horz 1 = 93(LC 12) Max Uplift 1 = -3(LC 12) 2 = -78(LC 12) Max Grav 1 = 202(LC 1) 2 = 119(LC 1) 3 = 89(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult--160mph (3-second. gust)_ Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed, end vertical left exposed;C-C for members and forces 8, MWFRS for reactions shown; Lumber DOL=1.60 plate gdp DOL=1.60 2) This truss has been designed for a 10.0 psi bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf an the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 2. LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=54, 3-0=20 Concentrated Loads (lb) Vert: 7=45 i.q rwua qa auos=mT anit}¢ratRa�alopnio¢o94@vn, nrr ualfl rgtrnpw a aq,t a, i r a, a.wlas; a, tearti u¢u.ra 9 N.,ak aar nmo, . n1 rm .xr am-rw : it a. nlrva0 s, qumq>Narms r.a sxaamr+. a.i ,rvw4mrax .am,=xr ry..+ ks4gi.a 1n. up p .m r.1 nq ,raaay Anfiony T. Tombc, III, R.E. a „aarlvnf r. -r. =r•-trMann..,rae wmage ml.ugrt,4 �pn awlays.lu wat a a Ixi 1 q eo,,po.am Mp ebr- sLrgpx n amn Nhgge&Mne y.a.: 4 : 80083 m t,wt tr,geM<w».a, .eae.aP.i�ra4pmn.1ldtl amu¢grr�fayen mrwwas.P.evu nh are.�ap>r.niay.a.w",.a,.famaa,r ,u..r..imonprya.mrm�um.e...:,, a4515t. Lucie Blvd. ,axmldiWN M .magMtllreuswtlm iwinv6up(q a¢I0.tafNr!n1a r RaEgn t Ptlfq 14gr IaaanRN Fart Plerw, FL 34946 (epi�Idt®7014 A -I icalinau-baoePll4m6o ltl,❑. Pep eaea ood6>1o.onen6x4nM1r¢sp elipkd vieen0rnuan pe:mirt er M14mAIH441Lmn A¢Aovrl.lem(4111,P(. Job ♦ russ russ ype ty y RENAR MORNINGSIDE QNRMSCMI)63B1 HJ7 Diagonal Hip Giber 2 1 A0214434 Job Reference o lional Pql Roof I susses, Fort Pierce, FL 34946, design@altruss.com 2x4 = 4.24 12 Run: 3x4 n 1.5x4 II LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.53 Vert(LL) -0.05 6-7 >999 360 TCDL 7.0 Lumber DOL 1.25 BC 0.58 Vert(CT) -0.11 6-7 >999 240 BCLL 0.0 ' Rep Stress Incr NO WB 0.44 HOrz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix -MS LUMBER - TOP CHORD 2x4 SP No.2 DOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/Size) 4 = 143/Mechanical 2 = 51910-10-7 (min. 0-1-8) 5 = 307/Mechanical Max Horz 2 = 182(LC 4) Max Uplift 4 = -107(LC 4) 2 = -145(LC 4) 5 = -50(LC 8) Max Gmv 4 = 143(LC 1) 2 = 519(LC 1) 5 = 307(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. - TOPCHOR15 -" 2-11=-818/130,11-12=-755/155, 3-12=-755/145 BOTCHORD 2-14=-230f748,14-15=-230r748, 7-15=-2301748, 7-16=230f748, 6-16=-2301748 WEBS 3-7=0/285, 3-6=-790/243 �1014--E 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=1311; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; end vertical left exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcumenl with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6.0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 He uplift at joint(s) 5 except at=lb) 4=107, 2=145. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 Ih dawn and 61 lb up at 14-9, 77 lb down and 61 lb up at 14-9. 32 lb down and 41 lb up at 4-2-8. 32 lb down and 41 lb up at 4-2-8, and 56 lb down and 87 lb up at 7-0-7, and 56 lb down and 87 lb up at 7-0-7 on lop chord, and 241b down and 35111 up at 1-4-9, 24 lb down and 35111 up at 1-4-9. 20 lb down at 4-2-8, 20 lb down at 4-2-8, and 38 lb down at 7-0-7, and 38 lb down at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASES) section, loads applied to the face of the truss are noted as front (F) or back (8). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (pit) Vert: 1-4=54, 5-8=-20 Concentrated Loads (Ib) Vert: 13=-72(F=-36, 8=-36)15=-9(F=-4, B=4) 16=61(F=-30, B=-30) 3x4 =5 PLATES GRIP MT20 244/190 Weight: 43 lb FT=10% 6. q IIntIE IN le SInG nESni{IItII-{nW1'lIIYSLf :dll[RfbIGY(P1T! CY { JIII'1 I:EINupI 4 rJ 4 Xnulk I G pA qRT,¢ ple1a11.1 b41Lld Y 1. 6 9d Mq OM 61'G. } Y11mmIM Yh ulbpel3JGk tl1.1 1 R41 Iqk SK 7f lry G. udl 14E!,p N A d pN Vu4 Ylny Itl%SrMI Mu}rl IY d 01[O,tl1. wf lMl bl P µCWq '4Y1 Anthony T. Tomba IH, I.E. d - dQJn S H ,M 61 tlmJ Mf o A RY nIXy N,T. h, dRIIL!Y Il Wtl_b tll YN 4nl IM11 P F tlh R9d ANI drat WO.lY.4 V - Ed NG. ItHF d S $eC6i d11V1NT.'^d ls',w. is :aK mPN p9mwf itln N6G4%r,ape{e � 4Cl IdLJN 61nIdW{ y ufLR EN 111hM Y: y,v 3bnnYL4 Guw.l.nf klT�6u nllm,6�ew.. v,c A4$15t. LeCIe 6Vd. ,3 •ulbdlp Gdef pM ^m9fldP'xlu,rvrtl� tm, _ q. Itlilhl+4i 1 1 SYC. 61x t 11'd39 aq]3 tlt IWd IXI FoA PiP¢e FL 34-46 6VI*41nb Uld 4I1e' T"u" -bl6q T. hA.111 I.E. le ledra o.elll'Uarvmrm ne. Imn s loA l'Ied. Aenl6unnev a miu ae LNmA l IeAUnses AeAmn Llonlolll,P.L P r 1 i r OTruss mss ype ty y RENAR MORNINGSIDE �' A0214435 WRMSCM1763B1 HUA Diagonal Hip Girder 1 1 q Job Reference o tionet) A-1 Roof Trusses, FortPierce, FL 34e46, design@a1 Wss.cora Run: 3x4= 1.Sx411 3-5-14 164-2 Dead Land Dee. = 118 In LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/deb Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Ved(LL) -0.09 6-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.87 Vert(CT) -0.22 6-7 >541 240 BCLL 0.0 ' Rep Stress Ina NO WB 0.84 Horz(CT) 0.02 5 We n/a BCDL 10.0 Code FSC20177rP12014 Matrix -MS Weight: 44 lb FT = 10 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly aoplied or 5-0-6 oc pur ins. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 4- -- = 181/Mechanical 2 = 57210-10-7 (min. 0-1-8) 5 = 305/Mechanical Max Herz 2 = 182(LC 4) Max Uplift 4 = -128(LC 4) 2 = -137(LC 4) 5 = -26(LC 8) Max Grav 4 = 181(1-C 1) 2 = 572(LC 1) 5 = 308(LC 3) FORCES. (Ib) Max. Comp,/Max. Ten. - All forces 250 (Ib) or less except when show2- - TOPCHORD 2-1 1=1 139/161,11-12=-1100/183, 3-12=-10791194 BOTCHORD 2-15=272/1068, 7-15=-272/1068, 7-16=272/1068,16-17=-272/1068, 6-17=272/1068 WEBS 3-7=01309, 3-6=-10921278 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; end vertical left exposed; Lumber DOL=1.60 plate gdp DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurient with any other live loads. 3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift at joint(s) 5 except at -lb) 4=128, 2=137. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 77 lb down and 61 lb up at 1-4-9, 7716 down and 61 lb up at 1-4-9, 46 lb down and 38lb up at 4-2-8. 32 lb down and 41 lb up at 4-2-8, and 59 lb dawn and 85 lb up at 7-0-7, and 56 lb down and 87 lb up at 7-0-7 on top chord, and 24 In down and 3511b up at 1-4-9, 24 lb down and 35 lb up at 14-9,.18:Ib.dewr�iE,4P2-_8.;73.Ib - down and 40 lb up at 4-2-8, and 35 lb down al 7-0-7, - and 38 lb dawn at 7-0-7 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Unifgnn Loads (pit) Vert: 1-0=-54, "- 20 Concentrated Loads (Ib) Vert: 12=-45 13=24(13) 14=-78(F=-36, B=42) 16=18(F=-4, 8=-14) 17=-64(1`=30, B=34) r a n,Rw�nnl a AIN nzsnf>AI¢f w+l rnnslrelOn[urnh. YI Yn't7 N n Ih hi]pl k tll l 1 Oey (qe p f uRrNu 1 aJ dvsl.' 4gMiw11 h W rchd 0 hp rra: q e 61 MI-i pnerdhn L RtYM 41W ttl r9u Wrnl tl MM x 19iw11 hM fld. mm�911tl IN -.di 1n G y „ � 6prr sRl®t0lEbl bolinsses�A.dnry LlamRell6 PF. RepiodeMoe open Roo@ ma - M�Rent 1.1onFo Iry PL An hin,, T. Tombo IIp, PX, 30083 4451 St. Lurie 8H4 Fort P:erce, FL 34946 O -I russ I ype Qty y RENAR MORNINGSIDE A0214436 SCM1763B1 J] Jack-0pen 6 1 Job Reference (optional) :1 Roof Trusses, Fort Pierce, FL Mani, desiga@a1t uw.mm Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 Mirek Industries, Inc. Tue Mar 51429:27 2019 Page 1 ID:Id_OOXyyT61Bi_TXoljwHHzefvK-dAlgYb8ysYBgp8ydPpOEn3iEXOLXNaREgEECzdyfc 3-0 7-0.0 1-4-0 7-0-0 3 6.110 12 Dead Load Dell. = 1/8 in m d �A 2 - -_•----_..1� _ � ewe- ..._.,,a..•�-� e e 4 3.4 = 7�0 - - 7-0-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deg L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.85 Vert(L-) 0.17 4-7 >478 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.65 Vert(CT) -0.22 4-7 >386 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.01 3 We n/a BCOL 10.0 Code FBC2017/rP12014 Matrix -MP Weight: 24 lb FT =10 LUMBER - TOP CHORD 2x4 SP No.2 DOT CHORD 2x4 SP No.2 BRACING- LOAD CASE(S) TOP CHORD Standard Structural wood sheathing directly applied or 2-2-0 oc pudins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be- installed during truss erection, in accordance with Stabilizer Installation guide. ! REACTIONS. (lb/size) 3 = 164/Mechanical- - 2 = 340/0-7-10 (min. 0-1-8) 4 = 85/10echanical Max Horz 2 = 164(LC 12) Max Uplift 3 =-117(LC 12) 2 = -79(LC 12) Max Gmv 3 = 164(LC 1) 2 = 340(LC 1) 4 = 126(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extenor(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100111 uplift at joint(s) 2 except (jt=lb) 3=117. h.q Mad. h LIn4 R.i}jdWYl Veit ll f f AI[6 YA9(RN La F aRA:'1 i.116JPI M+�@vin.mllml9ey+Angl1[i nmlfl III I lkl Llelm Y k' ... Id M+ tld O IPI. '1 BI laa WYulbmlWu ad! 1 Myf;� .Ievn GpaMymutl eltrl=+1 •tldptlntl •.v1 +4aW arS pin{+tl&+Yet. Itihl Ipput NeRl'b.n wrea lql b. uMJq N I4II. lf+un Lpq Ge+W.. LhP tr0 HP.:mur OtiM Cm Y(. SMmYdld N.IIFL `u4nnitlmlWdcW! Ilel Mml lsiuf 5..f+.m Wk✓RW.lm P 1,4 Anthony T. Telnha lllr C.E. 4Fi 1kT M! .. 1. mROMppay. col MY tl Y44(! Mtlllu+ 'Pf'Idlip!„IeWLn etlsxdYPniPIn+lYImmL7'�.sTiflmnlbknvl4upr,lrrlen�4pnmin+rMe.s.aYl+ =90083 f+.�w16d11 ntlm tl1eY ^I^911tlI1flnhra elM1 M-'a 9 II'IpiJy p i k y..rrme.aF4 wcyyagrnnnlad=nu_ MSl 6t. Lucie Bkd. .fodJ rs'6110201641dlAsb..... I Pierce, FL 34PG6 teolLnus-hlbvnrl.ientolg, P.L O rJs6 rush ype ty y RENARMORNINGSIDE �A0214437 vMMSCM1763B1 J17A Jack-0pen 1 1 Jab Reference (optional) A-1 Root busses, Yon Pierre, FL 34946, design@llalbuss.rem Run: 8.210 s May 18 2018 Print: 8.210 s May 18 2018 MTek Industries, Inc. Tun Mar 514:29:27 2019 Page 1 ID:Id_00XyyT61Bi_TXoljwHHze/vK-gjAlgYbBysYBgp8yd PpOEn3nkX09XNaREgEECzdyrc -14-0 7-M 7-4-0 7-0-0 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. TCLL 20.0 Plate Grip DOL 1.25 TC 0.57 TCDL 7.0 Lumber DOL 1.25 BC 0.66 BCLL 0.0 Rep Stress Incr NO WB 0.00 BCDL 10.0 Code FBC2017/iP12014 Matrix -MP LUMBER - TOP CHORD 2z4 SP M 30 SOT CHORD 2x4 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc purins. BOTCHORD Rigid ceiling directly applied or 10-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 3 = 203/Mechanical 2 = 415/0-7-10 (min. 0-1-8) 4 = 95/Mechanical Max Horz 2 = 164(LC 12) Max Uplift 3 = -97(LC 12) 2 = -34(LC 12) Max Gmv 3 = 203(LC 1) 2 - = 415(LC 1) 4 = 136(LC 3) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mpl-r, TCDL=4.2psf; BCDL=5.Opsf, h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces $ MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 3) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 2. DEFL in (loc) I/deft Ud Ved(LL) 0.16 4-7 >527 360 Vert(CT) -0.26 4-7 >316 240 Horz(CT) 0.01 2 n/a We LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25 , Plate Increase=1.25 Uniform Loads (plf) Vert: 1-8=-54, 3-9=-54, 4-5=20 Concentrated Loads (lb) Vert 8=A5 Trapezoidal Loads (plf) Vert: 8=,9-to-9=-54 Dead Load Dell. = 3/16 in and M PLATES GRIP MT20 244/190 Weight: 24 lb FT=10% t.q Ruln llh I IU9.n inrssun7eH'II,R\[am[n[m•rCM:YJ l,u[s-,e[IrM1 IrM 4,w Wadte MI a{®emy llb.v.m4M t.I xW.ltun L oa „tle. vw m199.y Wi mrxe lely INhil9 edl r Irm. Pa jl fp.Mr4x Mar tl re0.p a Pt' d r aJ,q ry WEryYMI pdn : 1 ty.Y xReah.l 141. 11 T epa Ltlnuba �b Anthony T. Tombo Ili, P.E. ' r] dh'. Iz 4 INIiy N bNldrypat„dtf qy4 dkN's(p,ll h'al,dtlblxl :C 1 Y 1 Y 1 9 tlhN4od Mtl dtr tY1�e11My 9 It1E 'Y,gJYY �3Mtl =8. "."hes,dlRmL ,n xM.. W�1tls IR W6gfeap9fdgb O'WI!rlL,bdMI1dW tr (<l¢e 1Mtl1e 1. ye31m1e14:Writ•InepnpvintRt{+u1�mw1[gt4Maxv. aLn gg525t Weeii vd. r lubivYl I m pd, v..mylltllle. - rdnYd N IC14bink W L rca6P d w y to a if r tlYOtl. (vppi¢I®9016414dhesseaAmloryl.lvmhalil P! pepodec avofllndomnenl,loarylmµnplv116itrd Mrnrde.r nnpe,m lswvto-mAlledLnuolerFvnyi lealolll,PL Fort P`ene, FL 34446 Job I russ I ype tyPly RENAR MORNINGSIDE WWSCM1763131 TO1GE Common Structural Gable 1 1 A0214438 Job Reference (optional) Iwssmm xun: tl3lu a May In Zulu Pnm 8.210 5 May 15 2ma Ml l i, lndushies, Inc. Tue Mar 5 14:29:28 2019 Page 1 ID:Icl 0OXyyT61Bi_TXaljwHHzefvK-8vj72ucmj9g1Hzj8B7Kdm?clpwmGpg6guZonezdyfb M1b4 4-00-0 W2 M 1'10-0 1d-0 1.84 3-3-12 I 3312 114 I 1-4 5 48 = n nnR�- 4 3xm = 3x10 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.22 Vert(LL) 0.09 9-10 >896 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.07 9-10 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(CT) -0.00 9 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matrix -MS Weight: 89 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No-2 WEBS 2x4 SP No.3 *Except• W3: 2x6 SP No.2 OTHERS 2x4 SP No.3 BRACING- TOPCHORD Structural wood sheathing directly applied orb-0-0oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (Ib/size) 10 = 435/0-3-8 (min. 0-1-8) 9 = 413/0-3-8 (min. 0-1-8) Max Horz 10 = 145(LC 11) Max Uplift 10 -196(LC 8) 9 = -190(LC 9) Max Grav 10 = 435(LC 1) 9 = 413(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry Gable End Details as applicable, or consult qualified building designer as per ANSI/rPI 1. 4) All plates are 1.5x4 MT20 unless otherwise indicated. 5) Gable studs spaced at 2-0-0 oc. 6) This truss has been designed for a 10.0 fist bottom chord live load nonconcurrenl with any other live loads. 7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 8) Provide mechanical connection (by others) of truss to bearing plate capabld of withstanding IGO lb uplift at joint(s) except 01=1b) 10=196, 9=190. LOAD CASE(S) Standard e Yy.11nutl ryb rtiiIS RS{JrdWl)Grn(plMlt(Ynll[ nSlLtll0.11'1\ r AIr'M I1.IAJylerae rndM•MnnM1l N#M Nllr-®Ib W#nll ls46,111tl 9 N M.W :M Md X1A0 Wl lumeiltl^ w" NM Ikl •II lrrlMpnTlryrtP 1 1 Mm tl gli9¢Irnn rlmpY Iutl qumlml°uMv11 M Eh yel Lry.1AwnIIWnx.M R11wn qr 6e p a ty d nnvbnx o-d sum dnm,rr ao.. lase. a MthonyT 'emho 711 >E. mr -w a,y m:,nnam4n xwtl.uml e.l 4mdlM1l tort ..•Ism¢w wp emmulmepx+q +.q am, xny aek w,v..a p90083 bldryir,p 4erx i..:,en.wlWWhptlmlWpq 1. LMyI #rm4Mibvm 4Npl mxhl. a9lp ram apw'µ...lrla.-a..pnHruwanrn.l: 1prupw i.Mh;,!gerrmr srwarr,...0 44515800t. a8hd. n Mulewll ,sN VMysrmgr-wlnnnmd ltrlml[ - Ih14 I. uSiR [•pmd IWaq IA�d VYvi r..H IRI • Fort Pierce FL 34946 ( pnipAl�fild Al[#allmvn Avumrl lemM1#III, 11. pep Ivn nn Andvm eul,meglmgnpnll'nedrmlmNewnopemiti M1.nA ld:ethv1u1116veyT.bm1a9Tp.b Job Truss I russ I ype Uty PlY RENAR MORNINGSIGE I A0214439 WRMSCM1763B1 T02 Common 1 1 ,14 Job Reference (optional) n-I MWI IIUs a, on ne .wavu, aeslgntmaI"..com 4x8 = 6.00 12 4 4/ 153 II 55x411 4 , 2 6 4x 11 10 9 8 1.5x4 II 3x10 = 1.Sx4 II 3x10 = rP LOADING(psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 ' BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/FP12014 CSI. TC 0.22 BC OX WB 0.09 Matrix -MS DEFL. in (loc) I/dell Vert(LL) 0.09 9-10 >887 Vert(CT) -0.07 9-10 >999 Horz(CT) -0.00 9 n/a L/d 360 240 n/a LUMBER - TOP CHORD 2x4 SP No.2 5) Provide mechanical connection (by others) of truss BOT CHORD 2x4 SP No.2 WEBS 2x4 S•Except• to bearing plate capable of withstanding 100lb uplift at P W3: 2x6SSP No.2 joint(s) except Qt=lb) 10=195, 9=195. BRACING - TOP CHORD LOAD CASE(S) Structural wood sheathing directly applied or 6-0-0 oc Standard purins, except end verticals. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 10 = 430/0-3-8 (min. 0-1-8) 9 = 43010-3-8 (min. 0-1-8) Max Horz 10 = 143(LC 11) Max Uplift 10 = -195(LC 8) 9 = -195(LC 9) Max Gmv 10 = 430(LC 1) 9 = 430(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. PLATES GRIP MT20 244/190 Weight: 75 lb FT = 10 f eq.R ltl q iY111f4j'illll}511 NS ro9 SfAn pl y,e l.M IeEIk PN uII'q'N18n I 4 W A'Ik`-hlAoll Xru0.lEld 9 -� Y61I glrt aN MI4' 41i .M Y kL iYJ dl. t pnq 1 w 5^ „k uavd pgnm x•.:IRi'W MIIy d MI p'tl Lq k1nlelrObll Wufil $i T pW 6N idN'^' IM1 AnthOPy T. TD.-160'11, P.E. N OUL: 4 II ! eyx lFN h0 NL' as III Wy. R"16lU WdI YrI_Niallu 9Vl dWPW MH qWi tbirtgl%'Fp -Nid WilgA,!-b I s =80083 Ibl Eap0111 W! Pnl t.✓ h1MW Wlmua 'w7 W 9f 1^ 4Y 1'tI Nh IH"WA Nb M,I 1F.b M'IIAIne.futWhnglL•1nikWre.l ni9ni'uPannfln iNMc'vm rct 44513[. Luce Blvd. Y u14.4lr [ 'glmi ncglldll q ii t q+ 1 Ibl 1 (q- E fMJly Iligb'aq IdN IIII Fort P:e:re, FL 34946 ("i'klo 26 A IWITasses. Amd p1.h.hULPd. Pep .oar ofd liewbm ev Ilmn,npm0d'ned Lnherl Re vlmn permilinl anbl lodLmrzl LlFrgrlJeIIM11I,P[. Job*Truss m55 I ype ty y RENAR MORNINGSIDE A0216440 YVRMSCM1763BI T03 Common 1 1 Job Reference (optional) A-1 ROor TN53¢5, Fon Pierce, FL 34946, tlesignQal Wss.cem Run: 8.21 0 3 May 18 2U18 fTnl: 8.21U S May 18 2018 Mn eK iodu sines. Inc. I U¢ mar 5 14:29:29 2019 Page 1 M ID:Id_OOXyyT61Bi_TXoljwHHzeNK-d5HWFEcOUTouv7HKlgmJC8grKAv?GxFvYJ W 5zdyfa f44-6 J9-26 1LI0150-i-9.10-03112 15:10 540 I 4x8 = 6.00f12 4 1.5x411 3x1o= 1.5x411 3.10 = 14 10 LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deb L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.40 Ved(LL) 0.09 9-10 >917 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Ven(CT) 0.07 9-10 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(CT) -0.00 9 nla n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 75 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No-3 *Except* W3: 2x6 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 6-M oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during buss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 10 = 419/0-3-8 (min. 0-1-8) 9. = 432/0-3-8 (min. 0-1-8) Max Horz 10 = -149(LC 10) Manx uplift - 10 = -196(LC 8) 9 = -196(LC 9) Max Grav 10 = 419(LC 1) 9 = 432(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOPCHORD 2-11=14V261 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE.7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except at --lb) 10=196, 9=196. LOAD CASE(S) Standard x'9'N,bl1 q'J htllltm33]I>JIIIj6:riY lilgflL].fll@I:Il1Y p1gU Mvl I.IIb PI '1'tl+V .11 4A b`91Po:dMl,fnlllwbP.Ik IA LMn W:xn: Md GI1"." YilY nNnlR+ tY ILhIT]bsnLt 111pn: h:Wlpmel fKxil Pam'. xr�P'x: W*tlmPtl uxtl I'N kM1k xPaftrtlmSLbiL4++rn CO:eh.M ML IMI!un p Mi hw P'I Anthony T. Tenon 111, F.E. M dML 4 4 Po lu.bMehOnx WO+a\ftr ,I PY M1I YlMq `t ,Ipll'. S 1 LAI M IAIYAY tlM1!06e:1 htlleud4.'nlv�ibghs4y:xq A9M ,tlYn iMne p,a..° e80083 ht.3aPM{x Lv-rt F -'NxPo1WNRP>xuf�1 (,W ,Ik411p(ry Y'egF+ YV IMN,! InMYIt .nxn4L P" Pd "51 St. Lucie 610. 1x4u1'dx,tt ,el •.mnhsrmf wtl <f lbin,u. q i1S4f+;Ar 1 .goad r4feq NgxlaMb la«Abnv Fan Fierce, FL 34946 ( T.T.&II.PJ. Aehae A16J}OIPAIiml6.va-[e lNvn ovrillllPamnd Im s h'lYed.u4nrhe xnna elmiss POM1PnAI[ediressel-APEvxrLienhxlll,P[. P^'9 Y P n ,1 PP p Job Trus—s— I may I ype ly y RENARMORNINGSIDE � A0214441 MMSCM176381 T04 omm Con 1 1 Job Reference (optional) Kun: 1 A-1 n001 I russes, �On YRmB, FL"3 b, dclgraJa l lsum.mm 4x8 = 6.00 f12 4 1.5x411 3x10= 1.Sx411 3x10 = LOADING(psf) SPACING- 2-" CSI. DEFL- in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC0.22 Vert(LL) 0.09 9-10 >887 360 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.07 9-10 >999 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.09 Horz(CT) -0.00 9 n/a nla BCDL 10.0 Code FBC2017frP12014 Matrix -MS Weight: 75 lb FT = 10% LUMBER - TOP CHORD 2x4 SP No.2 5) Provide mechanical connection (by others) of truss BOT CHORD 2x4 SP No.2 to bearing plate capable of withstanding 100 lb uplift at WEBS 2x4 SP joint(s) except Gt=lb) 10=195, 9=195. W3: 2x6 SSP P No.2 o.2 N BRACING - TOP CHORD LOAD CASE(S) Structural wood sheathing directly applied or 6-0-0 oc Standard pudins, except end verticals. BOTCHORD Rigid ceiling directly applied or 6-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during buss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 10 = 43010-3-8 (min. 0-1-8) 9 = 430/0-3-8 (min. 0-1-8) Max Horz 10 = 143(LC 11) Max Uplift 10 =-195(LC 8) 9 =-195(LC 9) Max Grav 10 = 430(LC 1) 9 = 430(LC 1) FORCES. (to) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.OpsF h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Ops1 on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. rrml ler+av�q.1 fa 4J nGR5$}("dIIIY}HEIIIRW Yf JIICIS(E 1' IttlY'3 nCa';a.l W IMb_p.amr4nd Wn AI k{hmq R, IYLbe IC untLlrl L M tl Wn tl9a deP.i bl,i,�a'srs IWhnB kNtl i pnq,lpmn4 1p °Y. L++- uJ rlM qm - .d phml q.,M19ru41 bYh hu;r Y=d hTA Wl ed IiLL'hly, p W i uNSy Andldny T. Tombo 111, P.E. ai,udv,lr 111........-uvlN�d5e0w 40mpM A P 4MYy0e„R' d 6 d�IMNI d'3Neml RL 1 qp aWSJ dwdtl r' Ydai94lR 9 6 YP ibr JiMG mi: n a80083 .r+ena,q. rue,e 1- n. a.raoraolmm.,mpN Wlhyr,99,eLldlr, axpa mepr4wwA m AWp.�Ips ttlmmvt+gn+d+ M_fdLlmuvpx.tmMq.r ^drm,aAd+a.v: 4451 St. Lucie Blvd. penuWrl Ms}eNgv mql, alp+,brrrt Th I.v W, lq.m muMly Fe. t q.d,W"Ngdadty 19 NeR11. Fan Pier., FL 34946 6 htO 7016 A I Emumsses AA T.Whe ill,❑ to dma ddi, ommert,mel lum,s Abhed. dremlAe.Iaea amiswlhumA I Aadksies Atdh of Tempo III, PI. P!'f / Pa 1 P^ f f o m55 mss ype ly y RENAR MOFWING6IDE VNRMSCM176381 TOS Common 1 1 A0214442 Job Reference (ootionall cwpn rIcusses, roarlerae, rL 04a4b,aeslgnaatuuss.wrn 4x8 = 6.00 12 2 _ _ 1 LOADING(psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 ' Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No2 WEBS 2x4 SP No3 *Except* W4: 2x6 SP No2 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 8 = 208/0-3-8 (min. 0-1-8) 7 = 46810-3-8 (min.0-1-8) Max Horz 8 =-118(LC 8) Max Uplift 8 = -89(LC 9) 7 =-183(LC 9) Max Grav 8 = 208(LC 1) 7 = 468(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=42psf; BCDL=5.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed ; end vertical right exposed; porch right exposed;C-C for members and forces 8 MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord and any other members. nun: 3x10 = 1.5x4 II CSI. DEFL. in (loc) I/den Ltd PLATES GRIP TC 0.23 Vert(LL) 0-16 7-8 >493 360 MT20 244/190 BC 0.53 Vert(CT) 0.13 7-8 >603 240 WB 0.09 Horz(CT) 0.00 7 n/a n/a Matdx-MP Weight: 60 lb FT=10% 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joints) 8 except (jt=1b) 7=183. LOAD CASE(S) Standard trvr,vlangtl tariva:nrssf;ttutl arauluxs4c+at nun. xtmT4a3';il[r-I aa,MwP�wal,4 ,d,er.nl 7rta.gm-,slsw.ttt am.ILm kwk w ,dn and 4mp uy ICI . rtrd+ndh tl hlNhk.tl4ltrtnlMTap.et S, �Frykdx.`N Yn Mq ,yu YR P< M W•k ILC3h1 .,h +}.er ITY 4PNa4MnIlI IYhP pw bdq .vlY lq d LStfe Y teAuS p uln In tlh O.Ln.b O..,t,m d!9 hMtl"r4n9 Se Cd41tl.i1.4. I L�YI bWN Ip.Ll ql tlWXW Idl d61' bIKW FI'q q Ct,AP iln'W Ck "V, d ArthnryT.Tombrr 80083 XirnPa111, D.E. & SM(x W f_k sWv..4 M 0. rn. xr ® W14( flgimme'flYfdlrYOh N Wnn ,1k! N lfl nbu t.gma,Yi Mn/f,LnlM1ym.I ntMa�a!^rtgflnssxmblx.90083 4Cwuld dll axaglM .agl.dM+twxni lw4mkxltq I1[IRWWMgo 1 Pq n! M9nl kM fdN Iu 4451 St. Llxie 81yd. Fort Vlerce, FL 34946 (eppilBb IDI4A llavlr cues-AoUacpi lem669VJ. rrpM naeeidndnanmt,nwplmgnpelbnN.11opan,nev pen to vhbmAlleonnuu IAoo Iiwde91, 1.f. o mss mss ype ty y RENARMORNINGSIDE �' A0214443 VVRMSCM1763e1 T06 Common i 1 � Job Reference (optional) . H-1 Moor INsses, ron rle(x, rL J4 b, oeslgn(N-alwss.MM Hun: 6.00 12 4,,8 = 2 3x10= 1.5x411 LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) I/dell Ud TCLL 20.0 Plate Grip DOL 1.25 TC 0.23 Vert(LL) 0.16 6-7 >490 360 TCDL 7.0 _ Lumber OOL 1.25 BC 0.52 Vert(CT) 0.13 6-7 >600 240 BCLL 0.0 ' Rep Stress Incr YES WB 0.07 Hom(CT) -0.00 6 n/a We BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 *Except* W4: 2x6 SP No.2 BRACING- TOPCHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals, BOT CHORD Rigid ceiling directly applied or 10-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 7 = 235/0-3-8 (min. 0-1-8) 6 = 357/0-3-8 (min. 0-1-8) Max Hocc 7 = 103(LC 11) Max Uplift 7 = -95(LC 9) 6 =-140(LC 9) Max Gmv 7 = 235(LC 1) 6 = 357(LC 1) FORCES. (lb) Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-123/300 WEBS 3-6=-183/305 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vu1t=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=13ft; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical right exposed: porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bonom chord live load nonconcument with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-M wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 7 except Qt=lb) 6=140. LOAD CASE(S) Standard PLATES GRIP- MT20 2441190 Weight: 58 lb FT=10% 'uq nnlMryN IZYII]L R51 i1 NtlLIFHfS(.t11H(A15i1tlT!((i$ifFh Ig4MM 4n rtgaM1 hnl &.}Smy.11CmhIM IN4ErL41 V>[ OtrM Ytltl 1fFY niY R+tilfk Wk t31ry tlll MT(ryarr3 drytn !a Ww I1p0 M i i ypltlrtlMmh J An(jlory T. Tombo IP., P.E. [i tl- fu LNI II N^-RJ tlhM mC rm- i Mllyfo T+ M tlhly R. I W-Y ( N ml1,'WNM.ot i Aii tl I '1,8gW0. 9 mMi db[RJiM Y+* .N bl ilre yi Mfmm 'IW M1M tlf InMe m1 Y 0Y4q(sypWltl In %YpWWilllll VII M�x,Sbpmt yl III Y y,zi NMnil•1�n[eupa,l.mi9nn!µrtmlim[ir+ 1 63 St.Lfol t. u1dM II W'n n,in gFtll1 vvoid II1 [: 9 1ltlm1"'; ln l re Lp 1 N l ey aNYm Ida,lnllll 44515� Lurie 3494 b h102016Al tndlnssesAlly l.lv E IILPI. Fort Pierre,R 4946 pPiit IP Pep'an o06sivrvm.vl,n.rylmm upl6D nd Homo,.mnrmm�umb,nAl PvvlLvssu-A6nnrP,lem6,04P.f. N55Truss Type tyPly RENAR MOIININGSIDE A0214444 RMSCMI?6387 VM03 Valley 1 1 Jab Reference (optional) Run: &210 s May 18 2018 Pnat: &210 s May 18 2u18 MTek lneuslnes. Inc. Tue Mar 5 14:2932 2019 Page 1 ID:Id_00XyyT61Bi_TXoliwHHzetvK-lgzetFfHnOATmbOvQzPZxnnk5YGUCe4ib WX?wPztlyFX 2 3 2x4 4 1.5x4 II I LOADING(psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/detl Ltd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.14 Vert(LL) nla - n/a 999 MT20 2441190 TCDL 7.0 Lumber IDOL 1.25 BC 0.07 Verl(CT) n/a - n/a 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) 0.00 n/a n/a BCDL 10.0 Code FBC20171-rP12014 Matrix-P Weight: 11 lb FT=10% LUMBER - TOP CHORD 2x4 SP No.2 BOTCHORD 2x4 SP No.2 WEBS 2x4 SP No.3 LOAD CASE(S) BRACING- Standard TOPCHORD Structural wood sheathing directly applied or 3-4-0 oc pur ins, except end verticals. BOTCHORD Rigid ceiling directly applied or 10-0-0 oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, m accordance with Stabilizer Installatpn_ guide. REACTIONS. (lb/size) 1 = 95/3-3-8 (min. 0-1-8) 3 = 9513-3-8 (min.0-1-8) Max Horz 1 — 52(LC 12) Max Uplift 1 = -15(1-C 12) 3 = A2(LC 12) Max Grav 1 = 95(LC 1) 3 = 95(LC 1) FORCES. (Ib) Max. Comp./Max. Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; 13CDL=5.Opsf; h=13ft; Cat. 11; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exlerior(2) zone; cantilever left and right exposed ; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0--0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 1, 3. t M A v... tr U45 nP nrutnl Fend rm t nnuswm m1111m r W r" .re w, ,.eo- W MrmxO, i IN pP e1-GP"mfila•f1I NP ILNiNnfdu ..W M rd t r.W1 w.t . Inmaal wwma=n.rd1 t Np Pu1�s.Mn lm..]nn •n4lnndMrMwdegxuN eWxP.eP rrr d+aPr Mcu eeP1w.,,.e nt lmadP r'.e li.rw�4 min Anthony Tombo ll'e, G.E. of o.0 Ib VaM S r"ln,tl i 4 nxMM° 4{tiY 4-i' W.6a. bYd6(Mh wfmg' lww h9l nrlrY.1 of .!W dM W.i r'4'isln Eey+:t2Av.l Ye9 W9tl vXid �6ru83 41WgM n,C Or 10 Wey1GWM/em ryzd b91^I '� r�"e+EG1Y6111Td1L1 sN4petl l•i�. iR1 4..rmetyl.IWntlLfm,q:y[,OgNgel,rynd ml Me[ntt ixsl 4451 St Lude ehd. M'Nwle! 1 enryxly , 11 p4a MPl. mlR;pyp 11N W.l6erin PMIyrmJ euy n,ged-It rNbr Fort Piece, FL 34946 � [ 'hIL]hl6/li °ILenes kli IIsm94 i14PF @rsd� dR demwel,. bm,n hhudruE llherna mnw hemAli al Lynx;-Ana<e l.lamh4111,6E v Job suss I russ I ype Qty y RENAR MORNINGSIDE A0214445 VmMSCM176351 VM05 Valley 1 1 Job Reference (optlOnaB .. , nwi immes, ion rierce, ru . u,ie. eeagrgii'utuiecum 9 g"T Run: 8.210 s May 18 2018 PrinC 8.210 s May 18 2018 MiTek Indusines, Inc. Tue Mar 5 14:29:32 2019Pagge 1 Re TXo1jwHHzefvK-lgwIFfHnOATmbOvOzPZxnnfdYEeCe4ibWX?wPzAf, 1.5x4 II 2 3 2x4 ' 1.5x4 It LOADING(psf) SPACING- 2-M CSI. DEFL. in (loc) Well L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.49 Ven(LL) n/a - n/a 999 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.25 Vert(CT) rda - n/a 999 BCLL 0.0 Rep Stress Ina YES WB 0.00 Horz(CT) 0.00 n/a n1a BCDL 10.0 Code FBC2017/TP12014 Matrix-P Weight: 191b FT = 10 LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 LOAD CASE(S) BRACING- Standard TOPCHORD Structural wood sheathing directly applied or 54-0 oc pudins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 be bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 16915-3-8 (min.0-1-8) 3 = 16915-3-8 (min. 0-1-8) Max Horz 1 = 93(LC 12) Max Uplift 1 = -28(LC 12) 3 = -74(LC 12) Max Grav 1 = 169(LC 1) 3 = 169(LC 1) FORCES. (lb) Max. Comp./Max.Ten. - All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=13tt; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Exterior(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) `This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2.0-0 wide will fit between the bottom chord and any other members. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 16 uplift at joint(s) 1, 3. Y .yr ✓9ev1Vr 5{-iIpSISfS..T_."rL)l«N"IU+t. 'IYi111 AOp FAIT. InMk paenq No-p,eb IPrwh n'tiT�M 44+fAIwFBti l+v Welipv Narpe mN ieP'pl. u I '+Nk con ra .r aea A I. - M. P it e„N ro m vwx.ed!.ra, I nmw aw ama.«<_ fT r YIAH. vu r9a:7:.,uy« av 1 .rxem Anthony T. Tombo Ila, P.E. ' A nb Mwy 2 9nwe}a f n,' wmn 19 4Lxgd fn h,em eelKen Y(m4klaeq„N n1-M1 ik4lnNd41'Y nod minn Ar5v3wNiWM.e,ite MYrSwA.la .pwdYd -80083 PK.Irwdf A Nn 1'{s'Mp.^n wlPYbndMkdMtisn,n V+Ad:ufi¢�Ww1MA -SaA do NY!vdp4u 1M111M,ht9a+eCmMla,a,4i dye,Nul+upt9muM,m, Mwhsn aw, 44515t. Lisle 01A. Kn a4X1; f r.IwMwavouf rn noy Yin,d{yhyw 996YArpgr _ fW f YtadStrl {L,pP .lk IAd V.L 6p,,' 0 2014 A 1 hrll nus k" l.Tv hflL1?J, dep ed.n vedf ldcmmem, ve4y la m, e p vb Elkd r �:velike. mrepe. mnfnv4vaA l4e14.fu{ AoWvgl.Lnbn III,P [. For Pierce. FL 349,16 To6 IN mss was ype RENAR MORNINGSIDE Aa214446 RMSCMT/6381 VM07 Valley I 1 .Inh Rafara �a /nnt'nnall 4. , ow, ...000, nUy.,I Run: 8.210 s Ma 18 2018 PdnC 8.210 s May 18 2018 Mf7ek Intlusuies, Inc. Tue Mar 51429:33 2019 Page 1 ID:Id_OOXyyT61Bi_TXoliwHHzefvK-VsX05bfvYiIKOkb52gwoT2JpYxV5x5KrgAHZSszdyf W 7-4-0 7-4-0 1.5x4 11 2 6.00 12_ _ _ _-"-A__ _ — __ _ _- 2u4 i 3 I LOADING(psf) SPACING- 2-" CSI. DEFL. in (loc) I/deft L/d TCLL 20.0 Plate Grip DOL 1.25 TC 0.54 Ved(LL) n/a - n/a 999 TCDL 7.0 Lumber DOL 1.25 BC 0.56 Vert(CT) n/a - nla 999 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Hom(CT) 0.00 me We BCDL 10.0 Code FBC2017/TPI2014 Matrix-P LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP No.2 5) Provide mechanical connection (by others) of truss WEBS 2ic4 SP No.3 to bearing plate capable of withstanding 100 lb uplift at BRACING- joint(s) 1 except at --lb) 3=107. TOP CHORD Structural wood sheathing directly applied or 7-4-0 oc LOAD CASE(S) pudins, except end verticals. Standard BOT CHORD Rigid ceiling directly applied or 10-" oc bracing. MiTek recommends that Stabilizers and required cross bracing be installed during truss erection, in accordance with Stabilizer Installation guide. REACTIONS. (lb/size) 1 = 243/7-3-8 (min. 0-1-8) 3 = 243f7-3-8 (min. 0-1-8) Max Horz 1 = 134(LC 12) Max Uplift 1 = -40(LC 12) 3 =-107(LC 12) Max Grav 1 = 243(LC 1) 3 = 243(LC 1) FORCES. (Ib) _ Max. Comp./Max. Ten. - All forces 250{tb)orfess except when shown. TOPCHORD 2-3=-177J3t0 NOTES- 1) Wind: ASCE 7-10; Vult--160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsf; 1=1311; Cat. II; Exp B; Encl., GCpi=0.18; MWFRS (envelope) and C-C Extedor(2) zone; cantilever left and right exposed; end vertical left exposed;C-C for members and forces & MWFRS for reactions shown; Lumber _ DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chard and any other members. PLATES GRIP MT20 2441190 Weight: 27lb FT=10% rrw'r Mag4 e: { 1 ]'uT sriM1tr .lu ax.l AWCPI mcvrlN'iglu n�.itrk 1 hx1PM«'1na idr..«a ru Nayb y'ip{^,J4 WtrY«+rMdw Wl «d t� FW 1 I x.«cr.«G Nf+rt up,nt61N«q rz n M« d4rwna[ 4fn(l tpk4t�lde«, txnhw hi 9n art itT.6,«ry «w n.wae.wxxupa-,� Iq 1 wtn»t,«tlnl romp a+.ke�y,r -: �. AnthonyT.'to [if, P.E. dnYmf 4nfl {.y; y "gdM0. b nnr lqr L.eq[ry: eY Y.g4(JWktl Miq.ueN'.µ Ngp.Ndzei"Ws±411 dMi JwryWigmq,, ewJkery MAbm .r«ti6id swn809d3 M1 W+1MupJ(A N Wwa rvdJ1lranuyn..atd 1.wr4.,reSinW TS p1,YfIr M1J W1 6aMyyMlnbu lM1l l?; 6�.ryM`xJMndht:« - .�&.y.n«nJka tlNn4e.«Rn 4451 St. WCe Blvd. Mw..liJll r vx,g q✓ ayllsY l,nv M41 _b�n,Lglm. hlaYgbuxn SnM t I IJW(L YIL. f N.n 1!'1 Fort Pierce, FL 34946 - bm§mct�IbA lieell.cus kdcerl lomSa OLrI. Aa6egl.Inopo OtrF. .. _ JANUARY 17, 2017 TYPICAL HIP / KING JACK CONNECTION I STDTL01 ;r. CORNERSET GENERAL SPECIFICATIONS MAX LOAD: 55 psf Roof -Load, 175 mph, ASCE —' 7-10, Exp. B, C up to 60' Mean Roof Height and Exposure D up to 30' Mean Roof Height. A-1 ROOF TRUSSES _ 4451 ST. LUCIE B%7- n"""�""""""` FORT FIERCE, FL 34946 Attach King Jack w/ (3) 16d Toe 772409-1010 Nails @ TC & 24" Strap w/ (6) 10d x 1.5" ea. end @ BC Attach End Jack's w/ (4) 16d Toe Nails @ TC & (3) 16d Toe Nails @ BC 0 ich Corner Jack's (2) 16d Toe Nails � TC & BC (Typ) Attach Corner Jack's w/ (2) 16d Toe Nails @ TC & BC (Typ) .yam a.yu e-s cnsrtty Fnas aras.rzmea zn.vmun3.Tmerm Mr,try,�m.ddvs wawsaapn-vd�.,aur,tu.uerx� snan.,u a•une w ma..x •d .aama..a ases¢w ..,.P: y, e,.y. nn „anae ,e,q..:q wbrewr vp i,.Nerctr...,��u newa+a'.u�M =n Antlwry T. tan6o III, P.E. ' m aF, L,uWe +a: < e ,m+ "m+ '^�a'.sm emc ax.am,uwham e+w 4�nmeslroa ks r sm.w5sra mnnmaavaawun w w-it x b9(,63 ¢Ya t+y.nd(rmv. s:ac k,n aren,K e. rP.,.ra v.+m Ta µems ra:rc nm.e*,w�w m a..sa wandavrat uram hnt.,PiaY..,eesnu...z.,.*M. 4551. St. Lucie OW nr L.xa 4ta4i ..ex .d hh, wa -xti aw^ aYwr n K4a,•tti Pdt we,ce, FL NW ( s kF S+.7816A14olinss pddm P, le.fnr,P.L [ edeo.ese iner.ca k. op} s 04od.0< .. ,m...... ftloepofdPJ: `FEBRUARY 17, 2017 1 ALTERNATE GABLE END BRACING DETAIL 1 STDTL03 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 ALTERNATE DIAGONAL BRACING TO THE BOTTOM CHORD 1' - 3' MAX. DIAG. BRACE AT 1/3 POINTS IF NEEDED IT IS THE RESPONSIBILITY OF THE BLDG. DESIGNER OR THE PROJECT ENGINEER/ARCHITECT TO DESIGN THE CEILING DIAPHRAGM AND ITS ATTACHMENT TO THE TRUSSES TO RESIST ALL OUT OF PLANE LOADS THAT MAY RESULT FROM THE BRACING OF THE GABLE ENOS. HORIZONTAL BRACE (SEE SECTION A -A) TRUSSSES I- 24' OZ. 2XG DIAGONAL BRACE SPACED 4B' O.C. ATTACHED TO VERTICAL WITH (4) - 16d NAILS, AND ATTACHED TO BLOCKING WITH (5) - 10d COMMONS. NAIL DIAGONAL BRACE TO PURLIN WITH TWO 16d NAILS. 2X4 PURLIN FASTENED TO FOUR TRUSSES WITH (2) - 15d NAILS EACH. FASTEN PURLIN TO BLOCKING W/ (2) - 16d NAILS (MIN.). _ ' PROVIDE 2X4 BLOCKING BETWEEN THE TRUSSES SUPPORTING THE \BRACE AND THE TWO TRUSSES ON \EITHER SIDE -AS NOTED. TOENAIL \BLOCKING TO TRUSSES WITH (2) - \ 10d NAILS AT EACH END. ATTACH DIAGONAL BRACE TO BLOCKING WITH (S) - 10d COMMON WIRE NAILS. END WALL CEILING SHEATHING BRACING REQUIREMENTS FOR STRUCTURAL GABLE TRUSSES STRUCTURAL GABLE TRUSSES MAY BE BRACED AS NOTED: METHOD 1: ATTACH A MATCHING GABLE TRUSS TO THE INSIDE FACE OF THE STRUCTURAL GABLE AND FASTEN PER THE FOLLOWING NAIL SCHEDULE. METHOD 2: ATTACH 2X_ SCABS TO THE FACE OF EACH VERTICAL MEMBER ON THE STRUCTURAL GABLE PER THE FOLLOWING NAILING SCHEDULE. SCABS ARE TO BE OF THE SAME SCAB ALONG SIZE, GRADE, AND. SPECIES AS THE -TRUSS VERTICALS. VERTICAL NAILING SCHEDULE: - FOR WIND SPEEDS 12D MPH (ASCE 7-99, 02, 05), 15D MPH (ASCE 7-SO) OR LESS, NAIL -ALL MEMBERS WITH ONE ROW OF IDd (.131' X 3') NAILS SPACED 6' O.C. __..._ . - - FOR WIND SPEEDS GREATER 120 MPH (ASCE 7-98, 02, 05), 150 MPH (ASCE 7-10) NAIL ALL MEMBERS WITH TWO ROWS OF SOB (131'X3') NAILS SPACED 6' D.C. (2X4 STUDS MINIMUM). MAXIMU"TU0-tENGTHS ARE LISTED ON PAGE I. ALI BRACING METHODS SHOWN ON PAGE I ARE VALID AND ARE TO BE FASTENED TO THE SCABS OR VERTICAL STUDS OF THE STANDARD GABLE TRUSS ON THE INTERIOR SIDE OF THE STRUCTURE. NOTE: THIS DETAIL IS TO BE USED ONLY FOR STRUCTURAL GABLES WITH INLAYED I STUDS. TRUSSES WITHOUT INLAYED / STUDS ARE NOT ADDRESSED HERE. STANDARD GABLE TRUSS UKAL ZTI In AN ADEQUATE DIAPHRAGM OR OTHER METHOD OF BRACING MUST BE PRESENT TO PROVIDE FULL LATERAL SUPPORT OF THE BOTTOM CHORD TO RESIST ALL OUT OF PLANE LOADS. THE BRACING SHOWN IN THIS DETAIL IS FOR VERTICAL/STUDS ONLY. JULY 17, 2017 STANDARD PIGGYBACK TRUSS STDTL04 �' A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772- 0i 1010 THIS DETAIL IS APPLICABLE FOR THE FOLLOWING WIND CONDITIONS: ASCE 7.98, ASCE 7.02, ASCE 7-05, ASCE 7-10 WIND STANDARDS UNDER ALL ENCLOSURE AND EXPOSURE CONDITIONS AS LONG AS NO UPLIFT EXCEEDS 377 LBS. REFER TO ACTUAL PIGGYBACK TRUSS DESIGN - DRAWING FOR UPLIFTS. NOTE: THIS DETAIL IS VAUD FOR ONE PLY TRUSSES SPACED 24' O.C. OR LESS. PIGGYBACK TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL PIGGYBACK TRUSS INFORMATION. /IN\ I- -I SPACE PURLINS ACCORDING TO THE MAXIMUM SPACING ON THE TOP CHORD OF THE BASE TRUSS (SPACING NOT TO EXCEED 24' D.C.) A PURLIN TO BE LOCATED AT EACH BASE TRUSS JOINT. ATTACH PIGGYBACK TRUSS TO THE BASE TRUSS WITH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATES SPACED 48'O.C. PLATES SHALL BE PRESSED INTO THE PIGGYBACK TRUSS AT 48' O.C. STAGGERED FROM EACH FACE AND NAILED TO THE BASE TRUSS WITH FOUR (4) 6d (1.5' X 0.099-) NAILS IN EACH PLATE TO ACHIEVE A MAXIMUM UPLIFT CAPACITY OF 377 LBS. AT EACH 2' X 8' TEE -LOCK MULTI -USE CONNECTION PLATE. (MINIMUM OF 2 PLATES) ATTACH EACH PURUN TO THE TOP CHORD OF THE BASE TRUSS. (PURLINS AND CONNECTION BY OTHERS) BASE TRUSS REFER TO ACTUAL TRUSS DESIGN DRAWING FOR ADDITIONAL BASE TRUSS INFORMATION. e \ q.ueailp t.ea r.«w ! M- r;w awe n,w.payn v,o-aaa, w.arcMaa,!wm.t-•�gm!re aMim.eneu d I aaw.,..w u.��. MMig4uq 1 t nw Mk4K .q,dM1 RM .'ywre$Mk Nm1U,tl!rM11 qY� eaemebryuE pwrtr111MMhxpWa NIXiRo- •®nbt}w, � ..uMmeMf yNwwnuap414pk�M.K '�M�AmY.rx�: xFbq M+w I .yyLpeie.M4i l�yaunu eH.t.IN AnNrny T. Tombo 111, RE. 6W83 44515L Lode Bhd. Fat Neme, FL 34"6 JULY 17, 2017 TRUSSED VALLEY SET DETAIL - SHEATHED I STDTL05 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 SECURE VALLEY TRUSS - W/ ONE ROW OF 10tl._ NAILS 6' O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS ATTACH 2X4 CONTINUOUS 42 SYP TO THE ROOF W/ TWO USP WS45 (1/4- X 4.5') WOOD SCREWS INTO EACH BASE TRUSS. DETAIL A GENERAL SPECIFICATIONS: 1. NAIL SIZE =3'X0.131"=10d 2. WOOD SCREW = 4.5' WS45 USP OR EQUIVALENT. 3. INSTALL SHEATHING TO TOP CHORD OF BASE TRUSSES. 4. INSTALL VALLEY TRUSSES (24- O.C. MAXIMUM) AND SECURE TO BASE TRUSSES AS PER DETAIL'A'. 5. BRACE VALLEY WEBS IN ACCORDANCE WITH THE INDIVIDUAL DESIGN DRAWINGS. 6. NAILING DONE PER NDS-01. 7. VALLEY STUD SPACING NOTTO EXCEED 48' O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS TRUSS CRITERIA: WIND DESIGN PER ASCE 7-98. ASCE 7-02, ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPit-==-. MAX MEAN ROOF HEIGHT = 30 FEET ROOF PITCH = MINIMUM 3/12 MAXIMUM 6112 CATERGORY 11 BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 MAX TOP CHORD TOTAL LOAD = 50 PSF MAX SPACING = 24' O.C. (BASE AND VALLEY) MINIMUM REDUCED DEAD LOAD OF 6 PSF ON THE TRUSSES. dludCflwW aL^'�4&qnw ee.x.u.te.r � [�arae'+�sala e k, .,e+a�. n:wpr,,.ywclYlyw.f..m:em Anthony T. Temb 111, P.E. ai�4�••^,axcz.m Y[.y antraz: rre :8GGci3 fbir�aky.:E:Iny[wmdFe:uw+wee:ass "51 St. Lucre Slyd. Fort Pierce, FL 34e46 FEBRUARY 5, 2018 TRUSSED VALLEY SET DETAIL STDTL06 Y A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 m-409-101a SECURE VALLEY TRUSS W/ONE ROW OF 10d NAILS 6' O.C. GABLE END, COMMON TRUSS, OR GIRDER TRUSS DETAIL A (NO SHEATHING) N.T.S. GENERAL SPECIFICATIONS: 1. NAIL SIZE =3'X 0.131'=10d 2. WOOD SCREW =3' WS3 USP OR EQUIVALENT. 3. INSTALL VALLEY TRUSSES (24.O.C. MAXIMUM) AND SECURE PER DETAIL •A'. 4. BRACE VALLEY WEBS IN ACCORDANCE WITH THE IN DIVIUAL DESIGN DRAWINGS. 5. BASE TRUSS SHALL BE DESIGNED WITH A PURLIN SPACING EQUIVALENT TO THE RAKE DIMENSION OF THE VALLEY TRUSS SPACING. 6. NAILING DONE PER NDS-01. 7. VALLEY STUD SPACING NOT TO EXCEED 48' O.C. GABLE END, COMMON TRUSS, OR GIRDER TRI M.R WIND DESIGN PER ASCE 7-98, ASCE 7-02,ASCE 7-05: 146 MPH WIND DESIGN PER ASCE 7-10: 170 MPH MAX MEAN ROOF HEIGHT =30 FEET ROOF PITCH = MINIMUM 3112 MAXIMUM 6/12 CATERGORY II BUILDING EXPOSURE WIND DURATION OF LOAD INCREASE: 1.60 — ATTACH_ 2X4 CONTINUOUS 712 MAX TOP CHORD TOTAL LOAD = 50 PSF SIP TO THE ROOF WUOUS TWO USP MAX SPACING= 24' O.C.(BASE AND VALLEY) WS3 (1/4- X 3') WOOD SCREWS MINIMUM REDUCED DEAD LOAD OF fi PSF ON THE TRUSSES. INTO EACH BASE TRUSS. .• -- +. +w� ..i ++rr�. rv+ M s.+w o's +•M I:• .._; .m .av w.. 4Jol( 'enilm 111. P.E. Illll t".xL i AMJ4Am I Ma tdxLnW. q 00 4Wfe6'WbgWM1PJ.lhew 4INNm Wn hIM k9tTP'j55'+H. �3'+ R 1Y ui,q � `'^ 3 B&mn' SwMI 1 vbTONbM Wpwa�SOh`W,�te�m[{M1M1 N)� VVm/@Y M ImV�dry...Tilin Mnyew. NlE 4IIG reti,ge,FM1ik.pypnl: i't4 MnaY✓vyiv >ti51 CI LME6Vd. .1NF (ray asSFEpa M4.,�N Tra 1 Ma�4 p• tr..lry+v! W!y U[MMhn� iM RL � Fo2 P' «z, i134W6 (pl iH 10631p.4 veuo 4.bv,lt bo0p,f eepden eetldndu.uelpwyl •sp eble.d+R<mtlettmrynq»gym. weA lFedLeius(1nlaeyLLeleil pe JUL( 17, 2017 - A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 ATTA( WIND DESIGN PER ASCE 7-98, ASCE 7- WIND DESIGN PER ASCE 7-10: 170 MPI MAX MEAN ROOF HEIGHT= 30 FEET CATERGORY II BUILDING EXPOSURE B OR C WIND DURATION OF LOAD INCREASE:' MAX TOP CHORD TOTAL LOAD = 50 PSI MAX SPACING = 24' O.C. (BASE AND VP SUPPORTINGTRUSBES DIRECTLY UND.n .n��c. inu�aa mwio� DESIGNED WITH A MAXIMUM UNBRACED LENGTH OF 2' -10. ON AFFECTED TOP CHORDS. I` ^IL (HIGH WIND VELOCITY) NOTES: 1. SHEATHING APPLIED AFTER INSTALLATION OF VALLEY TRUSSES. 2. THIS DETAIL IS NOT APPLICABLE FOR SPF-S SPECIES LUMBER. FOR BEVELED BOTTOM CHORD, CLIP MAY BE APPLIED TO EITHER FACE. CLIP MAY BE APPLIED TO THIS FACE UP TO A NON -BEVELED MAXIMUM 6112 PITCH BOTTOM CHORD NON -BEVELED BOTTOM CHORD CLIP MUST BE APPLIED TO THIS FACE WHEN PITCH EXCEEDS 6/12 (MAXIMUM 12112 PITCH) STDTL07 my ry k,eiw hll Wk.CRfi jSl:lfl'1pLM1l if'St([ti ItY1 Y({^^1^AIL1',IU�Yk 1Ahign Yw w( y hl k q'3$"eihtnmt o11 iY. tfw!km Qetf N¢. Rxi uMl iliM Nh -SA6t "1[[i gap9 _! qM M .16 r{ i pdtl, nq�.0 .q: B+t khiv[,64�q ii LFAf M[d tl, v'tIC. Twk¢p M1fr�v:.6 ' m1.a4xsi 4erlWq 4 wro�me Him dC iFM NaA h4Jls(Gtm YcHi64 46Nak iveuq HN !'x dxm SJdCg•+Ii.vtlhl aWpMfae mA � rdhmp� ^S F]! {4aNV{IYpry Y`2.irti5 31fy7 My! IWryW R$M.l lfww¢ISM6fMlb,V..y(411r41111p1 S ?�¢.tlp�a¢ Iw /fa hexi}u iGa[tlWlrch 1u15 fit( k.$ILefeMW rfrorwmdttr(ra9•rcM. �IIIFlrrIIw.+N. Iw w.ierx I ai�a vF.r'¢ I S<a. aa.+�dr,h o iAfx.;n nu i p.l. A,13m, T, Tw&o III, P.E. 84083 4451 St. Wde 31A. Foit P^ e,FL 34P G FEBRUARY 17, 2017 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 STANDARD GABLE END DETAIL TYPICAL 2X4 L-BRACE NAILED TO 2X4 VERTICALS V/10d NAILS, 6' O.C. VERI STUD SECTION B-B TRUSS'GEOMETRY AND`CONOITIONS- SHOWN ARE FOR ILLUSTRATION ONLY. VERTICAL STUD (4) - 16d NAILS IOd NAILS INTO 2X6 2X4 SP OR SPF *2 !CTION A z, STDTL08 2X6 SP OR SPF`, #2 DIAGONAL BRACE 16d NAILS SPACED 6' O.C. �— 2X6 SP DR SPF #2 -TYPICAL HORIZONTAL BRACE NAILED TO 2X4 VERTICALS '-V/(4) ='IDd NAILS-. DIAGONAL BRACE 4' - 0' D.C. MAX. SEE INDIVIDUAL ENGINEERING DRAWINGS IIj FOR TRUSS DESIGN CRITERIA. 12 PROVIDE 2X4 BLOCKING BETWEEN Q VARIES TO COMMON TRUSS THE FIRST TWO TRUSSES AS NOTED. * TOENAIL BLOCKING TO TRUSSES WITH (2) - 10d NAILS AT EACH ENO. ATTACH DIAGONAL BRACE TO BLOCKING WITH (5) - 10d NAILS (4) Ed NAILS MINIMUM, ROOF 3X4= PLYWOOD SHEATHING TO SHEATHING 2X4 STD SPF BLOCK * DIAGONAL BRACING ** L - BRACING REFER v n 1 REFER TO SECTION A -A TO SECTION B-B 24' MAX. / / 1. MINIMUM GRADE OF #2 MATERIAL IN THE TOP AND BOTTOM CHORDS. SOd 2. CONNECTION BETWEEN BOTTOM CHORD OF GABLE ENO TRUSS AND WALL TO 12' MAX NAILS. BE PROVIDED BY PROJECT ENGINEER OR ARCHITECT. 3. BRACING SHOWN IS FOR INDIVIDUAL TRUSS ONLY. CONSULT BLDG. _ ARCHITECT OR ENGINEER FOR TEMPORARY AND PERMANENT BRACING OF ROOF 4. SYSTEM. 'L' BRACES SPECIFIED ARE TO BE FULL LENGTH, SPF OR SP #3 OR BETTER WITH ONE ROW OF 10d NAILS SPACED 6' D.C. TRUSSES @ 24' OZ. 5. DIAGONAL BRACE TO BE APPROXIMATELY 45 DEGREES TO ROOF DIAPHRAGM / AT 4'-0' D.C. 6. CONSTRUCT HORIZONTAL BRACE CONNECTING A 2X6 AND A 2X4 AS SHOWN 2X6 DIAGONAL BRACE WITH 16d NAILS SPACED 6' O.C. HORIZONTAL BRACE TO BE LOCATED AT SPACED 48' O.C. ATTACHED THE MIDSPAN OF THE LONGEST GABLE STUD. ATTACH TO VERTICAL GABLE _ TO VERTICAL WITH (4) - STUOS WITH (3) IDd NAILS THROUGH 2X4 (REFER TO SECTION A -A) - 16d NAILS AND ATTACHED 7. GABLE STUD DEFLECTION MEETS OR EXCEEEDS L/240. TO BLOCKING WITH (5) - B. THIS DETAIL DOES NOT APPLY TO STRUCTURAL GABLES. DIAL. BRACE 10d NAILS. 9. DO NOT USE FLAT BOTTOM CHORD GABLES NEXT TO SCISSOR TYPE AT 1/3 POINTS TRUSSES. IF NEEDED 10. 10d AND 16d NAILS ARE 0131'X31I' AND 0131'X3S' COMMON WIRE NAILS HORIZONTAL BRACE RESPECTIVELY. (SEE SECTION A -A) 11. SOUTHERN PINE LUMBER DESIGN VALUES ARE THOSE EFFECTIVE 06-01-12 BY SPIB/ALSO. MINIMUM STUD SIZE SPECIES AND GRADE STUD SPACING WITHOUT BRACE 2X4 L - BRACE DIAGONAL BRACE (2) DIAGONAL BRACES AT 1/3 POINTS MAXIMUM STUD LENGTH 2X4 SP 431 STUD 12"O.C. 3-8-10 5.6-11 6&l1 11-1-13 2X4 SP#31 STUD 16"0.C. 3.3-10 49.12 6&11 9-10.15 2X4SP#3l STUo 24"O.C.t 3.11-3 5--12 8-1-2 2X4 SP 02 12" O.C. 5&11 6&11 11-8-14 2X4 SP #2 16"O.C. 4-9-12 6&11 10-8-0 2X45P a2 24'O.C.. 3-11-3 6.2-9 9-3-13 -j�-DIAGONAL BRACES OVER G' - 3- REOUIRE A 2X4 T-BRACE ATTACHED TO ONE EDGE. DIAGONAL BRACES -OVER 12' - 6' REQUIRE 2X4 I -BRACES ATTACHED TO BOTH EDGES. FASTEN T.q[] I BRACES TO NARROW EDGE OF DIAGONAL BRACE WITH IDd NAILS 6' O.C., WITH 3' MINIMUM END DISTANCE. BRACE MUST COVER 90% OF DIAGONAL LENGTH. T OR I BRACES MUST BE 2X4 SPF #2 DR SP #2. END WALL MAX MEAN ROOF HEIGHT =30 FEET EXPOSURE B OR C FEBRUARY 17, 2017 T-BRACE / I -BRACE DETAIL STDTL09 WITH 2X BRACE ONLY NOTES: T—BRACING / I —BRACING TO BE USED WHEN CONTINUOUS LATERAL BRACING �C IS IMPRACTICAL. T—BRACE / I —BRACE MUST COVER 91r/. OF WEB LENGTH. THIS DETAIL NOT TO BE USED TO CONVERT T—BRACE / I —BRACE WEBS TO CONTINUOUS LATERAL BRACED WEBS. A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772-409-1010 NAILING PATTERN T-BRACE SIZE NAIL SIZE NAIL SPACING 2X4 OR 2X6 OR 2X8 10d 6' O.C. NOTE NAIL ALONG ENTIRE LENGTH OF T—BRACE / ]—BRACE (ON TWO—PLY TRUSSES NAIL TO BOTH PLIES) BRACE SIZE FOR ONE -PLY TRUSS SPECIFIED CONTINUOUS ROWS OF LATERAL BRACING WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2X8 I —BRACE BRACE SIZE FOR TWO-PLY TRUSS SPECIFIED CONTINUOUS ROWS LATERAL BRACING OF WEB SIZE 1 2 2X3 OR 2X4 2X4 T—BRACE 2X4 I —BRACE 2X6 2X6 T—BRACE 2X6 I —BRACE 2X8 2X8 T—BRACE 2X8 I —BRACE T—BRACE / I —BRACE MUST BE SAME SPECIES AND GRADE (OR BETTER) AS WEB MEMBER. NAILS NAILS WEB NAILS WEB I -BRACE T-BRACE SECTION DETAILS FEBRUARY 17, 2017 LATERAL BRACING RECOMMENDATIONS I STDTL10 TO MINIMIZE VIBRATION COMMON TO ALL SHALLOW FRAMING SYSTEMS, 2XG 'STRONGBACK' IS RECOMMENDED, LOCATED EVERY B TO 10 FEET ALONG A FLOOR TRUSS. t;. NOTE 1: 2X6 STRONGBACK ORIENTED VERTICALLY MAY BE POSITIONED DIRECTLY UNDER THE TOP CHORD OR DIRECTLY ABOVE THE BOTTOM CHORD, SECURELY FASTENED TO THE TRUSS USING ANY A-1 ROOF TRUSSES OF THE METHODS ILLUSTRATED BELOW. 4451 ST. LUCIE BLVD. FORT PIERCE FL 34548 NOTE 2: STRONGBACK BRACING ALSO SATISFIES THE LATERAL BRACING REQUIREMENTS FOR THE 772409-1010 BOTTOM CHORD OF THE TRUSS WHEN IT IS PLACED ON TOP OF THE BOTTOM CHORD, IS CONTINUOUS FROM END. TO ENO, CONNECTED WITH A METHOD OTHER THAN. METAL FRAMING ANCHOR, AND PROPERLY CONNECTED, BY OTHERS, AT THE ENDS. INSERT WOOD SCREW THROUGH OUTSIDE FACE OF CHORD INTO EDGE OF STRONGBACK (00 NOT USE METAL FRAMING ATTACH TO VERTICAL CCC ATTACH TO VERTICAL USE DRYWALL TYPE SCREWS) ANCHOR TO TO TOP 1 NA IBLS (0.131'31)d \N AILS SCAB rITH ( 131.3X 3').. r NATTACH AILS TO VERTICAL I\ WEB WITH (3) - 10d BLOCKING BEHIND THE VERTICAL WEB IS RECOMMENDED WHILE NAILING THE STRONGBACK USE METAL FRAMING --I ATTACH TO VERTICAL ANCHOR TO ATTACH WEB WITH (3) - 10d TO BOTTOM CHORD NAILS (0131' X 3') ATTACH 2X4 VERTICAL TO FACE OF TRUSS. FASTEN TO TOP AND BOTTOM CHORD WITH (2) - IDd NAILS (0.131' X 3') IN EACH CHORD ATTACH TO CHORD WITH (2) N12 X 3' WOOD SCREWS (021S' OIAJ ATTACH TO VERTICAL INSERT SCREW THROUGH SCAB WITH (3) - 10d OUTSIDE FACE OF CHORD INTO NAILS (0131' X 3') EDGE OF STRONGBACK (00 NOT USE DRYWALL TYPE SCREWS) TRUSS 2XG 4' - 0' WALL STRONGBACK (TYPICAL SPLICE) (BY OTHERS) THE STRDNGBACKS SHALL BE SECURED AT THEIR ENDS TO AN ADEOUATE SUPPORT, DESIGNED BY OTHERS. IF SPLICING IS NECESSARY, USE A 4' - O' LONG SCAB CENTERED ON THE SPLICE AND JOINED WITH (12) - 10d NAILS (0131' X 3') EDUALLY SPACED. ALTERNATE METHOD OF SPLICING: OVERLAP STRONGBACK MEMBERS A MINIMUM OF 4' - 0' AND FASTEN WITH (12) - 10d NAILS (0.131' X 3') STAGGERED AND EQUALLY -SPACED (TO BE USED ONLY WHEN STRONGBACK IS NOT ALIGNED WITH A VERTICAL). BLOCKING (BY OTHERS) `FEBRUARY17,2017 1 LATERAL TOE -NAIL DETAIL I STDTL11 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34046 772409-1010 NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 45" WITH THE MEMBER AND MUST HAVE FULL -WOOD SUPPORT (NAIL MUST BE DRIVEN -- THROUGH AND EXIT AT THE BACK CORNER OF THE MEMBER ENO AS SHOWN). 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE THE LESSER VALUE OF THE TWO SPECIES FOR MEMBERS OF DIFFERENT SPECIES. TOE -NAIL SINGLE SHEAR VALUES PER NOS 2001 (LB/NAIL) DIA SP OF HF SPF SPF-S .131 88.0 80.6 69.9 68.4 59.7 U o .135 93,5 85.6 74.2 72.6 63.4 J .162 108.8 99.6 86.4 84.5 73.8 wi .128 74.2 67.9 58.9 57.6 1 50.3 z 0 0 .131 75.9 69.5 60.3 59.0 51.1 n .148 61.4 74.5 64.6 63.2 52.5 ri THIS DETAIL IS ONLY APPLICABLE TO THE THREE END DETAILS SHOWN BELOW. SIDE VIEW (2X3) 2 NAILS NEAR SIDE NEAR SIDE VALUES SHOWN ARE CAPACITY PER TOE -NAIL. SIDE VIEW SIDE VIEW APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. (2X4) 3 NAILS (2X3) 2 NAILS EXAMPLE: NEAR SIOE NEAR SIDE (3) - 16d NAILS (0162' DIA. X 35') WITH SPF SPECIES BOTTOM CHORD FOR LOAD ODRATION INCREASE OF 1.15: VF NEAR SIDE NEAR SIOE 3 (NAILS) X B45 (LB/NAIL) X 115 (ODU = 2915 LB MAXIMUM CAPACITY NEAR SIDE NEAR SIDE NEAR SIDE VARY FROM \ VARY TO 6 ' I \ 30 RTO GO* 30° TO GO 45.00° 45.00° 45.00' FEBRUARY17.2017 1 UPLIFT TOE -NAIL DETAIL I STDTL12 A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 772409-1010 THIS DETAIL SHALL BE USED FOR A CONNECTION RESISITING UPLIFT FORCES ONLY. BUILDING DESIGNER IS RESPONSIBLE FOR LOADS IN OTHER DIRECTIONS. TDE-NAIL WITHDRAWAL VALUES PER NOS 2005 (LB/NAIL) - -OIA. -SP- OF HF .SPF SPF-S .131 59 46 32 30 20 Z O J .135 60 48 33 30 20 !7 .162 72 56 39 37 25 J 2 CD .128 54 42 28 27 19 Z Z OJ .131 55 43 29 28 19 LLI .148 62 48 34 31 21 J 10 J N Q M Z .120 51 39 27 26 17 O Z .128 49 38 26 25 17 O .131 51 39 27 26 17 J O .148 57 44 31 28 20 M NOTES: 1. TOE -NAILS SHALL BE DRIVEN AT AN ANGLE OF 30' WITH THE MEMBER AND STARTED 1/3 THE LENGTH OF THE NAIL FROM THE MEMBER END AS SHOWN. 2. THE ENO DISTANCE, EDGE DISTANCE, AND SPACING OP NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. ALLOWABLE VALUE SHALL BE BASED ON THE SPECIE WITH LOWER NAIL CAPACITY BETWEEN THE TWO MEMBERS IN THE CONNECTION. VALUES SHOWN ARE CAPACITY PER TOE -NAIL. APPLICABLE DURATION OF LOAD INCREASES MAY BE APPLIED. EXAMPLE: (3) - 16d NAILS [O162"DIA; )C35') WITH SPF SPECIES TOP PLATE FOR VINO DOL OF 133: 3 (NAILS) X 37 (LB/NAIL) X 133 IDOL FOR WIND) = 148 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TD WIND FOR WIND DOL OF 1.60: 3 (NAILS) X 37 (LB/NAIL) X 1.60 IDOL FOR WIND) = 177 LB MAXIMUM ALLOWABLE UPLIFT REACTION DUE TO WIND IF THE UPLIFT REACTION SPECIFIED ON THE TRUSS DESIGN DRAWING EXCEEDS 147 LBS (177 LDS) BUILDING DESIGNER IS RESPONSIBLE TO SPECIFY A DIFFERENT CONNECTION. ••• USE (3) TOE -NAILS ON 2X4 BEARING WALL ••. USE (4) TOE -NAILS ON 2X6 BEARING WALL NEAR SIDE FAR S: )E TOP PLATE OF WALL VIEWS SHOWN ARE FOR ILLUSTRATION PURPOSES ONLY SIDE VIEW END VIEW FEBRUARY 5, 2016 TYP 2x2 NAILER ATTACHMENT STDTLI3 r 2x2 NAILER ATTACHMENT — -- - -- ---- - - ---- - --- __ — GENERAL SPECIFICATIONS A-1 ROOF TRUSSES MAX LOAD: 55 psf�Roof-Load, 170 mph,-ASCE- -- FORTRT PIERCE, F4-34946 772-409-1010 7-10, 29'-0" Mean Height, Exp. B, C or D. 1.0X4 - T April 11, 2016 I TYPICAL ALTERNATE BRACING DETAIL STDTL14 I FO EXTERIOR FLAT GIRDER TRUSS y A-1 ROOF TRUSSES 4451 ST. LUCIEBLVD. .-- .FORT -PIERCE; FL-3494?- .--e-•• - >--409-1010 (4) 12d -- TRUSS 241f O.C. --\ UPLIFT CONNECTION (SEE ROOF TRUSS) EXTERIOR FLAT - GIRDER �12 VARIES (4) 12d MAX 3011 (21-611) _ 2x6 #2 SP (Both Faces) 2411 O.C. — SIMPSON H5 I I n..y-Y,.....p e. .racnMlx1mn r rt arlma•u'vlwner xW n v r w .fie wan o- fM..k w.�.w wN WIN wY'1 a. ^'i v W.i f.Wh�! fp 'ry!w W IWtp i(w: I Y' ..I^I y ML Ms 4�^ IW 4•wL I.M r 6iq 0.thonY T.Tm74946 F. .ain~�pwslLn.v r atW ,w.Naab'..}+r.•nihtHe'.r. r W:.fnt vlt a ww f..Yr-Jo 1 rt+wnMM1 RtrM.•oxv.(niuv �.Jun�n.+'-rt .+�s � t.. I 'FEBRUARY 17, ZO17 STANDARD REPAIR DETAIL FOR BROKEN CHORDS, WEBS, AND STDTL15 DAMAGED OR MISSING CHORD SPLICE PLATES A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 T72409-1010 TOTAL NUMBER OF NAILS EACH SIDE OF BREAK X (INCHES) MAXIMUM FORCE (LBS) 15% LOAD DURATION SP OF SPF HF 2X4 2X6 2%4 2X6 2X4 2X6 2X4 2X6 2X4 2X6 20 30 24' 1706 2559 1561 2342 1320 1980 1352 2028 26 39 30' 2194 3291 2007 3011 1697 2546 1738 2608 32 48 36' 2681 4022 2454 3681 2074 3111 2125 3187 38 57 42' 3169 4754 2900 4350 2451 3677 "2511 3767- 44 66 4g' 3657 5485 3346 5019 2829 1 4243 2898 4347 • DIVIDE EQUALLY FRONT AND BACK ATTACH 2X_ SCAB OF THE SAME SIZE AND GRADE AS THE BROKEN MEMBER TO EACH FACE OF THE TRUSS ( CENTER ON BREAK OR SPLICE) WITH IOd NAILS (TWO ROWS FOR 2X4, THREE ROWS FOR 2X6) SPACED 4' D.C. AS SHOWN (A31' OIA. X 3'). STAGGER NAIL SPACING FROM FRONT FACE AND BACK FACE FOR A NET 2' O.C. SPACING IN THE MAIN MEMBER. USE A MIN. 3' MEMBER END DISTANCE. THE LENGTH OF THE BREAK (C) SHALL NOT EXCEED 12'. (C=PLATE LENGTH FOR SPLICE REPAIRS) THE MINIMUM OVERALL SCAB LENGTH REQUIRED (L) IS CALCULATED AS FOLLOWS: L = (2) X + C 1. Syp1 BREAK 0-\ \ 1100dd'NAILS NEAR SIDE \01 \ TRUSS CONFIGURATION +10d NAILS FAR SIDE AND BREAK LOCATIONS -- FOR ILLUSTRATIONS ONLY 6' MIN X' MIN THE LOCATION OF THE BREAK MUST BE GREATER THAN OR EQUAL T❑ THE REQUIRE❑ X DIMENSION FROM ANY PERIMETER BREAK OR HEEL JOINT AND A MINIMUM OF S' FROM ANY INTERIOR JOINT (SEE SKETCH ABOVE). DO NOT USE REPAIR FOR JDINT SPLICES NOTES: 1. THIS REPAIR DETAIL IS TO BE USED ONLY FOR THE APPLICATION SHOWN. THIS REPAIR DOES NOT IMPLY THAT THE REMAINING PORTION OF THE TRUSS IS UNDAMAGED. THE ENTIRE TRUSS SHALL BE INSPECTED TO VERIFY THAT NO FURTHER REPAIRS ARE REQUIRED. WHEN THE REQUIRED REPAIRS ARE PROPERLY APPLIED, THE TRUSS WILL BE CAPABLE OF SUPPORTING THE LOADS INDICATED. 2. ALL MEMBERS MUST BE RETURNED TO THEIR ORIGINAL POSITIONS BEFORE APPLYING REPAIR AND HELD IN PLACE DURING APPLICATION OF REPAIR. 3. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 4. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR.PIATES_AI_THE..OINTS OR SPLICES. 5. THIS REPAIR IS TO BE USED FOR SINGLE PLY TRUSSES IN THE 2X_ ORIENTATION ONLY. 6. THIS REPAIR IS LIMITED TO TRUSSES WITH NO MORE THAN THREE BROKEN MEMBERS. FEBRUARY17,2017 I SCAB APPLIED OVERHANGS I STDTL16 r' �'.,•I A-1 ROOF TRUSSES 4451 ST. LUCIE BLVD. FORT PIERCE, FL 34946 n24B9-1010 5'LKII EK1A: �+xa �'�='... ^`.�-� - ^`+•. LOADING: 48-10-0-ID DURATION FACTOR: 115 SPACING: 24. O.C. TOP CHORD: 2X4 OR 2XG PITCH: 4/12 - 12/12 HEEL HEIGHT: STANDARD HEEL UP TO 12' ENERGY HEEL ENO BEARING CONDITION NOTES 1. ATTACH 2% SCAB (MINIMUM #2 GRADE SPF, HF, SP, OF) TO ONE FACE OF TRUSS WITH TWO ROWS OF 10d COMMON WIRE NAILS (148' DIA. X 3') SPACED 6' O.C. 2. THE END DISTANCE, EDGE DISTANCE, AND SPACING OF NAILS SHALL BE SUCH AS TO AVOID UNUSUAL SPLITTING OF THE WOOD. 3. WHEN NAILING THE SCABS, THE USE OF A BACKUP WEIGHT IS RECOMMENDED TO AVOID LOOSENING OF THE CONNECTOR PLATES AT THE JOINTS OR SPLICES. 2X SC NOTE: TRUSS BUILT WITHOUT AN OVERHANG. THIS DETAIL IS NOT TO BE USED WHEN OVERHANG HAS BEEN BROKEN OFF. IMPORTANT THIS DETAIL TO BE USED ONLY WITH TRUSSES (SPANS LESS THAN 409 SPACED 24' O.C. MAXIMUM AND HAVING PITCHES BETWEEN 4/12 AND 12/12 AND TOTAL TOP CHORD LOADS NOT EXCEEDING 50 PSF. TRUSSES NOT FITTING THESE CRITERIA SHOULD BE EXAMINED INDIVIDUALLY. REFER TO INDIVIDUAL TRUSS DESIGN FOR PLATE SIZES AND LUMBER GRADES