Loading...
HomeMy WebLinkAboutBUILDING SITE PLANSPermitting and it (01 „�I 1 Professionals: Owner Coleman Floor Company 3100 Tollview Drive Rolling Meadows, IL 60008 Architect Construction, fog a Fae''ility for Floor Commerce Circle Ft. Pierce, Florida The Architecture Company and Associates, Inc. 220 Freeman Street Longwood, FL 32750 Ph: (407) 332-8299 Fax: (407) 332-6669 License No: FL AA0002811 Mechanical - Electrical Engineer neer Gast Engineering, Inc. 316 Cypress Landing Drive Longwood, FL 32779 Ph: (407) 774-3188 Fax: (407) 774-8059 License No: FL PE0038638 Contractor KNS Construction, Inc. 1465 Gene Street Winter Park, FL 32789 Ph: (407) 647-1234 Fax: (407)647-5234 License No: CGC040554 Plans an Index of Construction Documents Sheet Title A-1 Foundation Plan - Finish Schedule A-2 Floor Plan - Reflected Ceiling Plan A-3 Elevations - Door and Window Schedule A-4 Sections P-1 Plumbing Floor Plan M-1 HVAC Floor Plan M-2 HVAC Notes and Schedules M-3 HVAC Details E-1 Power and Data Floor Plan E-2 Electrical Lighting Plan E-3 Electrical Notes, Riser and Schedules These drawings dated March 8, 2004 and revised on July 12, 2004 4 I O AUG 1 0 2004 SLCFD z- )q- as' ST. LUCIE COU'rTY FIRE DISTRICT REVIEWED FOR COMPLIANCE SLBJEC'T TO FIELD INSPECHONS SEE ATTACRED R , EViSION SVEFT REVIEWED BY:,- %' L DATE: eR-/o — luiv THESE PLANS k'D AJ1 . P Vv70 1 V ARE SUBJECT TO &47 COAXilw REQUIRED BY NLI.i7' IN:' =X� I MAY BE KFCFeY L 69,: I , COMPLY Y>+TH ALL APPIC,vN, L r--i CONCRETE AND MASONRY NOTES: ALL DETAILS AND SECTIONS 5HOWN ON THE DRAWIN65 ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR 51TUATION ELSEWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL 15 5HOWN. 2 CONCRETE MA50NRY UNITS SHALL BE HOLLOW OR SOLID UNIT MASONRY IN ACCORDANCE WITH A5TM C90 OR G 145 AND SHALL HAVE A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1400 P51. 3 MORTAR SHALL BE EITHER TYPE M OR 5 IN ACCORDANCE WITH A5TM C 270. 4 GROUT SHALL HAVE A MAXIMUM COARSE AGGREGATE 51ZE OF 3/b" PLACED AT AN b TO II INCH SLUMP AND HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 2000 P51 AT 2b DAYS WHEN TESTED IN ACCORDANCE WITH A5TM G 1014, OR IN ACCORDANCE WITH A5TM C 476. 5 CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRESSIVE STRENGTH OF 2500 P51 AT 2b DAYS. 6 REINFORCING STEEL SHALL BE MINIMUM GRADE 40 AND IDENTIFIED IN ACCORDANCE WITH A5TM A 615, A 616, A617,ORA706. T JOINT REINFORCEMENT, ANCHORS, TIES, AND WIRE FABRIC, SHALL CONFORM TO THE FOLLOWING STANDARDS: (1) A5TM A b2 FOR JOINT REINFORCEMENT AND WIRE ANCHORS AND TIE5, (2) A5TM A 36 FOR PLATE, HEADED AND BENT BAR ANCHORS. (5) A57M A566 FOR SHEET METAL ANCHORS AND TIES. 6 ALL CONTINUOUS VERTICAL OR HORIZONTAL BAR5 IN FOOTINGS, FOUNDATION WALL5, 5LAB5 AND OTHER CONCRETE SHALL BE LAP -SPLICED, WHERE NECESSARY OR DESIRABLE, BY WIRING TOGETHER IN CONTACT. LENGTH OF ALL LAP5 SHALL BE 40-BAR DIAMETERS OR 24" MINIMUM, WHICHEVER 15 GREATER. q BED AND HEAD JOINT5 SHALL BE 5/6" THICK. 10 THE BED JOINT OF THE 5TARTIN6 COURSE PLACED OVER FOOTINGS SHALL BE PERMITTED TO VARY IN THICKNESS FROM A MINIMUM OF 1/4" TO A MAXIMUM OF 5/4". II MA50NRY WALL5 SHALL BE RUNNING BOND CONSTRUCTION. 9-5AGE (MINIMUM) HORIZONTAL JOINT REINFORCEMENT, IN ADDITION TO REQUIRED VERTICAL REINFORCEMENT, SHALL BE PLACED IN BED JOINTS AT NOT MORE THAN 16" O.G. 12 LONGITUDINAL WIRES OF JOINT REINFORCEMENT SHALL BE FULLY EMBEDDED IN MORTAR OR GROUT WITH A MIN. COVER OF 5/b" WHEN EXPOSED TO EARTH OR WEATHER 4 1/2" WHEN NOT EXPOSED TO EARTH OR WEATHER. 13 REINFORCING STEEL SHALL BE NO. 5 BAR5, UNLE55 NOTED OTHERWISE. 14 FOR FOUNDATIONS MINIMUM CONCRETE COVER OVER REINFORCING 5AR5 SHALL BE 3" IN FOUNDATIONS WHERE THE CONCRETE 15 CAST AGAINST AND PERMANENTLY IN GONTAGT WITH THE EARTH. COLUMN FOUNDATION &�HEDULE SYMBOL TYPE "A" "B" DEPTH REINFORCING ANGHOR BOLTS Aj MAIN FRAME 3'-6" 3'-6" 2'-0" 5-#5 EACH WAY 4 - 5/4" DIA. A307 X Ib" + 4" HK. 2A ENDWALL 2-0" 2'-0" 1'-4" 3-#5 EACH WAY 4 - 3/4" DIA. A30'7 X 12" + 2" HK. ACORNER 2'-O" 2'-0" 1'-4" 3-#5 EACH WAY 4 - 3/4" DIA. A30'7 X 12" + 2" HK. 4� CENTER 3'-6" B'-b" 2'-0" 5-#5 EACH WAY 4 - 5/4" DIA. A307 X 16" + 2" HK. NOTES: I. VERIFY ANCHOR BOLT 51ZF-5 WITH METAL BUILDING, MANUFACTURER FINISH SCHEDULE NOTES: FLOOR BASE WALL5 CEILING MATERIAL SPECIFICATION: I. COLOR AND PATTERN OF MATERIALS ALL FLOORING 4 BASE TO BE PROVIDED BY OWNER. AS SELECTED BY OWNER. —1 is)ACOUSTICAL PANEL 01-6: ARMSTRONG "CORTE6A" LAY -IN CEILING SYSTEM, SQUARE EDGE, OR EQUAL. z z Z Q LPL W W O IL X N T-. w w LLI z < -i o 0 0 v 75-1 pl tu w z �o 0 z �z4�-A f o p v 4 w 4 v r Q v v p N N 3 -A A I&I X Q m Q p Lu a p Z Q� LI Z Z Z Z Q Q lLl IYQ ���0>�z----�X(L tl7 Hz MARK ROOM NAME w v w 0 v i Q 0 M K It w U o Q li Q lL Q DL Q 1L u� Y_ - N X l w w x O z GLG. H&T. REMARKS l i z 101 COVERED ENTRY 61 • • • 10'-0 102 ESTIMATOR • • • ® a'-0 105 OFFICE • • • ® a'-0 104 OPEN OFFICE AREA • • • • a'-O 105 OFFICE • • • • a'-O 106 OFF I GE • • • • a'-O 107 OFFICE • • • • a'-0 Ob OFF I GE • • • To IOa BREAK ROOM • •• a'-0 110 SUPPLIES • • ® Is a'-O III ELEGTRIGAL • • • • N/A 112 TOILET • • • • b'-O 113 PA55A6E • • • • a'-0 114 WOMEN • • • • b'-O 115 MEN • • • • b'-O 116 TOILET • • ® le 8'-O 117 WAREHOUSE OFFICE • • ® ® a'-0 IIS WAREHOUSE • • ® • N/A Ila DOCK • • • • N/A SEE GIVIL DRANIN65 120 WAREHOUSE OFFICE • • • ® ® a'-O 121 SUPPLIES • ® ® ® a'-O 122 GONFERENGE • • ®1125 OFFICE ® ® ®• a'-O 124 PA55A6E • • ®• a'-O EXTERIOR 5LA55 _-1 • FIFIL I I I NOTE: NOTE: DESIGN OF COLUMN BASE 4 TOP 1 I I ' I TO BE PRE-ENGINEERED BY STEEL I ALL FILL SHOULD BE INORGANIC, NON- PLASTIC GRANULAR FRAME SUPPLIER. INSTALL PER SOIL.(GLEAN SANDS). THE FILL SHOULD BE PLACED IN LEVEL MFR'S SPECIFICATIONS. I 1 I LIFTS NOT TO EXCEED b" L005E THICKNESS. THE FILL SHOULD I I 6 1 BE COMPACTED TO A MINIMUM 95% OF THE 501L'5 MODIFIED I I PROCTOR MAXIMUM DRY DENSITY A5 DETERMINED BY ASTM TT 1 A-4 I I SPECIFICATION D-1557. IN -PLACE DENSITY TESTS SHOULD BE 1 I I 1 PERFORMED ON EACH LIFT TO VERIFY THAT THE RECOMMENDED / \ _ I I DEGREE OF COMPACTION HAS BEEN ACHIEVED. #5 X 20' LONG ONE PIECE HAIRPIN TO 1 I BE BENT AROUND ANCHOR BOLTS J L- - - - "V" K W/ 45 DE6. BEND WHERE SHOWN. FOUNDATION PLAN NOTES: / \ 1 pI I I I I� PROVIDE 4" CONCRETE SLAB WITH 12" WIDE x b" DEEP THICKEN EDGE. J I I I 1 SLAB TO SLOPE FOR POSITIVE DRAINAGE. "A" r > 1 1 ( I 20 2'-0" WIDE X I'-0" DEEP CONCRETE FOOTING W/ 3-#5 EACH WAY. w 1 1 I I ■ I j�/jj� 15 SHOWN THUS ■ . SEE SECTIONS. �OLUI - �l FOUNDATION REFER N�E VERTICAL REINFORCING,FILLED I i�i I I DISTANCE BETWEEN FILLED CELLS TO BE NOT GREATER THAN 8'-O" DI 1 I I 1 ® 3000 PSI 5" CONCRETE SLAB W/ bx6-WI.4xAI.4 HAM OR FIBER NO SCALE I MESH REINFORCING OVER b MIL VAPOR BARRIER COVER COMPACTED I POISONED SOIL TREATED FOR TERMITE INFESTATION, I 1 I I I I 4'-5l I 25'-0" 4 1 1, 10'-0" 4'-0" 10'-0" 1E 744 141 10.-0.. 4'-0" 10'-0" 74'-0" I I 37'-4" TO CONTROL JOINT 11 5 1 I 7 1 1 L------ -- —'— -- — -- _—_— ' — — — — — -- ---- — ——_ — — -----— — in I in 11 1 I ILL II :I 2 1 p I O 1■ rl r � z I 2 __ m II A-4 0 - II I 1 o Ln II QQ —�I■ o � CONTROL JOINT (TYPICAL) O II L O JII IJ ev I A ■I 21 1 I I II b ® II II �o II A-4 � II oil 1 1 3' 6" -2" 3' 6" II'-2" 3' 6" Ib'-O" 3' 6" Ib'-O" 3' b" b'-O" 3' 6" 17'-9" I ' 4'-O" '-0" II II A A = :� IA II �I �I I I II 1 I■ II r II 2 r - II 1■ I 1 II 13 I .\1 (D 1 ° o LL r-1 ° I �1Az U I � ��J ALL o ❑ II 4 0 II o 11 0 Ell11I II■ u, i1 Ell ~ ❑ o ❑ ❑ to it I ■ II ❑ 1I I n 2 - IN ■ I A I cv 11 El in\ AI / \ / \ / \ \ ✓ \ / U) III � 3 1 = f} '�I Q--- -----J L------J L------J - L----------J -- - - -K L------ -D--J L--------� ---.--- -J - �- L-------- -------- - -J ----`----- 1 � F -1 F_ 44'-b" TO CONTROL JOINT A-4 44'-b" TO CONTROL JOINT 134'-b" THESE PLANS AND ALL PROPOSED WORK F® U N D A T 1® N C L A N REVISIO ARE SUBJECT TO ANY CORRECTIONS SCALE: I/b" REQUIRED BY FIELD INSPECTORS THAT nw TA MAY LTC IVC:.CDaAf1IT in vnurn iv COMPLY WITH ALL APPLICABLE CODES. REVISIONS: I Q7/12/04-OWNER I O CC0 a O O bJD (D O O 0 in A � � A V :.r n\ O W � x ��►J O V O n` W � (D cq Roq W, IN O z • LJ i� m GO CD CO i crl crz C'Q F' O DC w u C) U� cd U U Fr �y oa U rZ4 PROJECT NO.10504 DATE: MARCH b, 2004 SHEET: A-1 DESIGN NOTES: BUILDING DATA: THIS PROJECT 15 IN COMPLIANCE WITH THE 2001 FLORIDA BUILDING CODES: BUILDING CODE, CHAPTER lb, SECTION III FOR 140 MPH WIND FLORIDA BUILDING GORE, 2001 EDITION LOADS, AND TABLE 160b.25 FOR THE EXTERIOR DOOR AND WINDOW WORK. SEE DOOR AND WINDOW SCHEDULES FOR LIFE SAFETY LODE - NFPA 101 - 2000 EDITION WIND DESIGN PRESSURES. BUILDING, CLASSIFICATION: WIND DATA: 5TORA6E 5-1 (OFFICE LE55 THAN 25%) WIND, SPEED: 140 MPH BUILDING, CONSTRUCTION TYPE: WIND IMPORTANCE FACTOR: (IN) = 1.0 TYPE IV - UNPROTECTED - SPRINKLERED RIND EXPOSURE: "B" (FBG 1606.1.8) BUILDING PHYSICAL PROPERTIES: WIND LOADS (FBG): WAREHOUSE AREA: 11,114 50. FT. (141%) WIND LOADS BASED ON FBG, SECTION 1606.2 OFFICE AREA: 3,IgO 5Q. FT. (21%) WIND VELOCITY = 140 MPH, USE FACTOR 1.0 TOTAL AREA: 14,1104 50. FT. DESIGN CRITERIA: ALLOWABLE AREA: 48p00 SQ. FT. FLOOR LIVE LOAD (GENERAL AREAS): 100 P5F BUILDING OCCUPANT LOAD: FLOOR LIVE LOAD LOAD (SERVICE BAY AREA): 125 P5F DEAD LOADS: FOLLOW 2001 FBG APPENDIX A, TABLES Al 4 A2 WAREHOUSE AREA: II,77I4 50. FT. / 500 = 3q OCCUPANTS OFFICE AREA: 3,IgO 50. FT. / 100 = 32 OCCUPANTS ROOF LIVE LOAD: 20 P5F SEE METAL BUILDING SHOP DRAWIN65 FOR ADDITIONAL LOADS TOTAL OCCUPANT LOAD: -71 OCCUPANTS SPRINKLER NOTE: SPRINKLER PLAN SHOP DRAWINGS BY A FLORIDA LICENSED SPRINKLER CONTRACTOR ARE TO BE SUBMITTED FOR PERMITTING PRIOR TO INSTALLATION. INSULATION NOTE: INSULATION WHEN CONGEALED SHALL HAVE A FLAMESPREAD RATING OF NOT MORE THAN i5, AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 450 INSULATION WHEN EXPOSED SHALL HAVE A FLAMESPREAD RATING OF NOT MORE THAN 25, AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 450 c ENERAL NOTES AND REQUIREMENTS: PLUMBING FIXTURE REQU REMENT5 BASED ON 'f I OCCUPANTS TOTAL REQUIREMENTS: 36 MEN / 36 WOMEN WATER CLOSETS LAVATORIES DRINKING, FOUNTAINS SERVICE SINKS MEN I I I I WOMEN I I TOTAL PROVIDED WATER CLOSETS LAVATORIES DRINKING, FOUNTAINS SERVICE SINKS MEN 2 2 2 1 WOMEN I I I. ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF THE BUILDING 8. UNLESS OTHERWISE INDICATED IN THESE SPECIFICATIONS, THE GENERAL CODE, AND ALL OTHER APPLICABLE CODES, RULES, AND REGULATIONS. CONTRACTOR, ALL SUBCONTRACTORS AND SUPPLIERS SHALL PROVIDE GUARANTEES BASED ON INDUSTRY REC06NIZED STANDARDS FOR THEIR 2. The Architecture Company and Associates, Inc. SHALL BE THE "ARCHITECT PRODUCTS AND SERVICES, IN No CASE SHALL THESE GUARANTEES REMAIN OF RECORD" AND SHALL RETAIN THE ORIGINAL CONSTRUCTION DOCUMENTS. IN EFFECT FOR LE55 THAN ONE YEAR FROM THE DATE OF CERTIFICATE THE PLANS AND 5PECIFIGATIONS ARE THE PROPERTY OF THE ARCHITECT AND OF OGCUPANGY. SHALL NOT BE USED OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERM155ION OF THE ARCHITECT AND/OR THE OWNER. el. SUBCONTRACTORS SHALL PROVIDE THE GENERAL CONTRACTOR WITH SUCH PLANS AND INFORMATION AS MAY BE REQUIRED FOR THE ISSUANCE 3. THE ARCHITECT SHALL NOT HAVE CONTROL OR CHARGE OF AND SHALL OF ACCEPTANCE CERTIFICATES. NOT BE RESPONSIBLE FOR CONSTRUCTION MEANS, METHODS, TECHNIQUES, 5EQUENCE5, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS OR 10. THE GENERAL CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING PROGRAMS IN CONNECTION WITH THE WORK, FOR THE ACTS OR OMISSIONS ALL APPLICABLE PERMITS. OF THE CONTRACTOR, SUBCONTRACTOR, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF ANY OF THEM TO II. PROVIDE FIRE EXTINGUISHER HAVING A MINIMUM RATING OF 3-A, 40-5G, CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. MOUNT AT 2'-cl 1/2" A.F.F. AT LOCATIONS SHOWN ON PLAN. 4. DO NOT SCALE DRAWIN55. 12. CONTRACTORS SHALL BE LICENSED TO PROVIDE SERVICES WITHIN THE COMMUNITY OF THE AUTHORITY HAVING JURISDICTION. CONTRACTOR'S 5. THE GENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VERIFY SHALL ALSO INCLUDE NECESSARY INSURANCE COVERAGE TO INDEMNIFY ALL CONDITIONS, DETAILS, AND DIMENSIONS BEFORE PROCEEDIN6 WITH THE THE OWNER, ARCHITECT, AND A6ENT'5 THEREOF FROM DAMAGES RESULTING WORK AND SHALL BE RESPONSIBLE FOR COORDINATION OF THE SAME. THE FROM THE PERFORMANCE OF THE CONTRACTOR'S WORK. ARCHITECT SHALL BE NOTIFIED OF ANY DISCREPANCIES. 13. INTERIOR FINISHES SHALL COMPLY WITH CHAPTER b, AND TABLE 803.3 6. JOB SUPERINTENDENT SHALL VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FOR SPRINKLERED BUILDINGS. COMMENCING WORK, 14. CONTRACTORS SHALL PROVIDE ALL MATERIALS, EQUIPMENT, TOOLS 1. IT 15 INTENDED THAT ALL WORK BE FIRST QUALITY, AND AGGOMPLI5HED TRANSPORTATION AND LABOR REQUIRED TO COMPLETE THE SCOPE OF IN A WORKMANLIKE MANNER BY SKILLED CRAFTSMEN USING ACCEPTED HORK IDENTIFIED WITHIN THESE CONSTRUCTION DOCUMENTS. PRACTIGE5 AND METHODS APPROPRIATE TO THE TRADE INVOLVED. s � °1 - Yill ■i� 7 MF=-7MMF=7WMF=70j MWE EMEMMMOMOMMMMMM R E F L E T E D C,,,E I L I N FLAN 50ALE: Ila" = I'-O" OPPIGE AREA SEE MECHANICAL AND ELECTRICAL 5HEEET5 FOR ADDTIONAL INFORMATION. v DOCK I lq SEE CIVIL DRAHIN65 2q'-4" -71.4. 10'-0" 4'-0" l0.-0.. I A-4 FI 170 IT,q i v ■ IWX30" MIRROR PAPER TOWEL DISPENSER 0] AGG3=550RY 56HEDULE: 54" MIN. I? MIN. OI PAPER TOWEL D15PENSER: 15 MIN. 4BOBRIGK 8-262 OR EQUAL 36" MIN. WMA 12" 1, 42" MIN. (�2 TOILET TISSUE DISPENSER: BOBRIGK B-2868 OR EQUAL (3)MIRROR: BOBRIGK B-290 ID50 OR EQUAL r O GRAB BARS: b I 4 TP b u BOBRIGK 5-440 SERIES OR EQUAL z g 6u - z m IV (V Z 2IF ry lV SEE PLAN SEE PLAN KNE�ARANGE SEE CIVIL DRAWINGS FOR PAVING T O Le 1 F IN I L) K L L-) L:Lfi A I 10'-0.. 4'-O" 10'-0 " L T \ I 119B i r i I i i i I ■ 8 I i I A-4 o HAREHOUSE I 118 F.E: I i I ■ I I I 6 2 A-4 THESE PLANS AND ALL P10POSED 1,"JO K ARE SUB jIECT TO AIR Y CO IImOTICII REQUIREDIBY FIELD INSPECTORS THAT MAY BE ECESSARY IN ORDER TO COMPLY NTH ALL APPLICABLE CODE . . I cV In r uu'i n STRIPE FLOOR W/ 2" WIDE YELLOW PAINT YV/ W FACE TO FAG OF STRIPE TO INDICATE PATH O� TRAVEL TO EXIT CIS HANDICAP ACCESSIBLE DRINKING FOUNTAIN i I i F.E. loc v I 8 I I A-4 A-4 21'45" LJ 50ALE: 1/2" = P-O" _4--MANEUVERIN6 CLEARANCE PER FAGBC, FIG. 25 WAREHOU° OFFICE 120 134'-&" TI'-0" SUPPLIES ILJ p OFFIC OFFICE 121 ! 125 103 LKHD. 121 122 681-01. 123 103 24 PASSAGE LEAR FLOOR SPACE 124 CLOSETS ( xb FIG. 26. (TYP) FILE CABINETS CLEAR FLOOR SPACE FOR LAVATORY (30"x48") COMPLYING Tol IIb IIb Wl 11-4.Iq.3, FIG. 52. (TYPICAL) ® PARTITION PARTITION ME BY OTHERS BY OTHER! 5 115 0 in OPEN OFFIO AREA 14iNDICAP ACCE551BLE 104 D�j22INKING FOUNTAIN 114 114 114 �'q I ' 4 O PA55A6E o D -4 v' 113 eo <r IOq 10& 107 106 I10 p BULKHD. 10'- 10'-0" 10'-0" 10'-0" ET ]a ®8'-O" BREAK+ OFFICE OFFICE OFFICE 1 SUPPLIES ROOM i6 08 cl 106 110 lociIII ECT. `b 28'-8" 21'-6" F L 0 0 R FL AN 50ALE: lb" = I'-O" O I I O I I I HALL LEGEND: METAL STUD WALL5 MASONRY WALL5 INSULATED KALL5 4'-O" 2 ESTIMATOR FIG v , �O GOV D Q V ENTR a IOI 101 F.E. � H1 �r STEEL COL. BY MTL. i — BLDG. MFOR. t f �--,-ff I a WIVQSJUN�j REVISIONS: QT/12/04-OWNER x � CID O Q � 40 cc m a O 0 c O m q 4QP O � U A � Fr n ` a COD °O c O v � U Z4-3 V a) z 9 cq aV b 0 , r a) CIS U 4-01 V .� 0 Z O w 0 IINNNNI .� W U F" iy Q O PROJECT NO. 10504 DATE: MARCH b, 2004 SHEET: A-2 WIN AINI�)®W 5GHEDULE MARK HEAD ABOVE 100'-0" FRAME STOOL OLA55 DETAIL DE51 ON WIND PRESSURE REMARKS WIDTH HOT. MAT. COLOR T K. Y TINT A b'-Oil 4'-O" 4'-b" ALUM. BRONZE NONE MFISR. IMPACT 6LAZIN6 NONE 3/A-5 35.3/-3b.2 PSF FIXED B 8' O" 12'-O" 4'-b" ALUM. BRONZE NONE M66R. IMPACT 6LAZIN6 NONE 3/A-5 31.6/-34.6 PSF FIXED LINE OF TRUCK WELL SEE CIVIL DRAWIN65 METAL FRAME n 1r n& G& =T =I ===_=WIGL=" VVI\II�VL JVII\I WEST ELE\/ATI ON SCALE: 1/5" = I'-O" PAINTED GMU TH15 ELEVATION METAL FRAME 3 ANCHORS PER JAMB 51, GMU LINTEL NOTE: ALL PRE -CAST LINTELS TO BE CA5T-GRETE OR EQUAL AND 16" WIDER THAN THE OPENING THEY SPAN. LINTELS DE516NATED P5 ARE POWER STEEL LINTELS. SEE SECTIONS. N — 5PLI T-FACE 12" D' FAB. 3 5/43" METAL STUDS (DOUBLE AT OPENIN65) 1/21, GYP. BD. 5" GMU CAULK FINISH WHERE 'SPLIT -FACE SHOWN FINISH �O®SAME DAME FR®F I L E 5 SCALE: 5" = 1'-0" mi 14/d" H'_n" I :VA" iv TEMPERED OLA55 Q i- 5GALE: 1/4" = I'-O" 2 1/2" 6YP5UM BOARD ON METAL FURRING PROVIDE "J" MOULD SHIM AS REQUIRED 1 5/4" X 4 1/2" ANODIZED ALUMINUM STOREFRONT CONSTRUCTION (BRONZE) CAULK THESE PIONS A"10 ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS 3_ REQUIRED BY FIELD INSPECTORS THAT ® N C� AY BE NECESSARY IN ORDER TO CUMPLY WITH ALL Ph, Pp CODES. --....�_ __... >)�_/ la 1 1 1 l— 1—" X r-N I I �_/ I N SCALE: I/&" = I'-O" PAINTED GMU THIS ELEVATION LI= Al GAal = =kl1 =V n6 �_A MT =l ===_=1\IIGl ,I SCALE: I/8" = 1'-0" 5PLIT-FACE GMU TH15 ELEVATION n& �_ . 10 l/= =AM=1 =V X /� I I lJ I `4 L ----J SCALE: 115" = I'-O" SPLIT -FACE .MU TH15 ELEVATION DOOR SCHEDULE DOOR TYPE TEMPERED OLA55 A B G D HARDWARE SET SET #1 NOTES: 11/2 PAIR 4" X 4" BUTT HIN6E5 I. KEY PER TENANT'S INSTRUCTIONS. PRIVACY LOGK5ET W/ LEVER TYPE HANDLES 2. PAINTED DOORS TO HAVE ONE GOAT SET #2 PRIMER d ONE GOAT LATEX SATIN 1 1/2 PAIR 4" X 4" BUTT HINGES ENAMEL FINISH. LOCKSET WITH THUMB LATCH 3. PROVIDE DOOR STOPS FOR DOORS ALUMINUM THRESHOLD (MAX. 1/2" H6T.) WITHOUT GLO5ER5. SET #3 4. ALL SOLID GORE DOORS TO BE 1 3/4" 1 1/2 PAIR 4" X 4" BUTT HINGES THICK. LOGK5ET WITH LEVER TYPE HANDLES 5. STAINED DOORS TO HAVE TWO GOATS SET #4 URETHANE SATIN FINISH. 1 1/2 PAIR 4" X 4" BUTT HINSE5 LATGH5ET WITH LEVER TYPE HANDLES MARK R POOR POODES DOOR FRAME HARD- WARE SET DESIGN WIND PRE55URE REMARKS TYPE HOT. WIDTH MAT. FIN15H MAT'L. WIDTH JAMB ELEV. 101 PAIR A 7'-0" 3'-0" ALUMINUM BRONZE ALUMINUM 4 1/2" 1 1 2 33.7/-36.7 PSF CLOSER; WEATHERSTRIP 102 SINGLE G b'-b" 3'-0" 5G WOOD STAIN METAL 5 5/4" 2 2 3 103 51NOLE G 6'-b" 3'-0" 5G WOOD STAIN METAL 5 5/4" 2 2 3 105 51NOLE G b'-b" V-O" 50 WOOD STAIN METAL 5 5/4" 2 2 3 106 51NOLE G b'-b" 3'-O" 50 WOOD STAIN METAL 5 5/4" 2 2 3 107 51NOLE G b'-b" 3'-O" 5G WOOD STAIN METAL 5 5/4" 2 2 3 lob 51NOLE G 6'-b" 3'-O" 5G WOOD STAIN METAL 5 3/4" 2 .2 3 loci 51NOLE G 6'-b" 3'-0.1 50 WOOD STAIN METAL 5 5/4" 2 2 4 110 SINGLE B 3'-0" 5G WOOD STAIN METAL 5 5/4" 2 2 3 III 51NOLE B b'-b" 3'-0" 5G WOOD STAIN METAL 5 5/4" 2 2 3 112 51NOLE B 6'-b" 3'-0" 5G WOOD STAIN METAL 5 3/4" 2 2 1 CLOSER; WEATHERSTRIP; SIGN: "TOILET" W/ HANDICAP SYMBOL 113 51NOLE B 6'-b" 3'-0" 5G WOOD 57AIN METAL 5 3/4" 2 2 3 CLOSER; WEATHERSTRIP 115A 51N6LE B 7'-0" 3'-01, INS. MTL. PAINT METAL 5 1/2" 3 3 2 33.V-36.7 P5F CLOSER; WEATHERSTRIP 114 51NOLE B " 6'-6 3'-0" 5G WOOD STAIN METAL 5 3/411 2 2 1 CLOSER; 516N: "WOMEN" W HANDICAP 5YM130L 115 51N6LE B 6-b" 3'-011 5G WOOD 57AIN METAL 5 5/4" 2 2 1 CLOSER; SIGN: "MEN" W/ HANDICAP 5YM50L 116 2 SINGLE B 6-6" 3'-011 5G WOOD 57AIN METAL 5 5/411 2 2 3 CLOSER; VON: "TOILET" W/ HANDICAP SYMBOL II7 51N6LE B 6'-b" 3'-0" 5G WOOD STAIN METAL 5 5/411 2 2 3 10 51N6LE B 7'-011 3'-0" INS. MTL. PAINT METAL 5 1/2" 3 3 2 33.7/-36.7 PSF CLOSER; WEATHERSTRIP 119 ROLL -UP D 10'-0" 10'-0" MFOR. 30.0/-33.0 PSF 119A ROLL -UP D 10'-011 10'-0" MFOR. 30.0/-33.0 P5F I MB ROLL -UP D 12'-O" 10'-0" MF6R. 50.0/-55.0 P5F 119E ROLL -UP D 12'-0" 10'-0" MFOR. 5G WOOD 50.0/-55.0 P57 120 2 51N&LE B b'-b" 3'-0" STAIN METAL 5 3/4" 2 2 3 121 2 51NOLE G b'-b" 3'-0" 5G WOOD STAIN METAL 5 3/4" 2 2 3 122& 51NOLE G b'-b" V-O" 5G WOOD STAIN METAL 5 3/4" 2 2 3 123 2 51NOLE G b'-b" 3'-0" 5G W00D STAIN METAL 5 5/4" 2 2 3 124 2 51NI5LE 5 b'-b" V-O" 5G WOOD STAIN METAL 5 3/4" 1 2 1 2 5 CLOSER; WEATHERSTRIP REVISIONS: Q5/Ib/o4-5LD6. DEPT. Q7/12/04-OWNER O tfJ L` c GV z c, R O 40 Cm 41 0 a Q 4.3 o U A w eq eq eq o °4 VD _1 _ O V � U O cc cq F Gil � Es u I:X4 PROJECT NO. 10504 DATE: MARCH b, 2004 SHEET: A-3 W GMU BOND BEAM #5 HORIZ: TIE TO CHAIR BLOCK REINFORGIN6 GROUT ALL CELLS FULL &" GMU W/ 1-#5 FROM FOOTING TO BOND BEAM SEE FOUND. PLAN PROVIDE AEEP HOLES AT 48" O.G. DOCK PAVING-5EE CIVIL DRAWINC75 _ FLOOR LINE J i COMPACTED FILL I TOP OF FOOTING 5-#5OF CONTINUOUS O TOP AND BOTTOM II L � _ BETA I N I N0 AALL SEGTI ON 3/4" = I'—O" CHAIR BLOGK--� #5 HORIZ.- EXTEND 24" INTO PERIMETER FTC. DOCK BUMPER AS REOV. BY OWNER b" GMU W/ 1-#5 FROM FOOTING TO SLAB SEE FOUND. PLAN GROUT ALL GELL5 FULL — DOCK PAVING -SEE CIVIL DRAWINGS 3-#5 CONTINUOUS 4" CONCRETE SLAB (SEE FOUNDATION PLAN) FLOOR 100'-O" LINE COMPACTED FILL TOP OF q5'_4" FOOTING Q 2'-O" DOG< AALL SECTION 3/4" = 1'-0" GEILIN6 HOT. + 4" ACOUSTICAL PANEL CEILING 1/2" GYP. BOARD PROVIDE R-II IN50LATION WHERE 5HOAN ON PLANS \ SEE FOUNDATION PLAN 100'-O ,R-Iq INSULATION VARIES ACOUSTICAL PANEL GEILIN6 (OMIT CEILING ON WAREHOUSE SIDE) 3 5/5" (5TN25) METAL STUDS AT 16" O.G. SEE FINISH SCHEDULE FOR BASE AND FLOOR FINISHES INTERIOR HALL SECTION 3/4" = 1'-0" ROLL -UP DOOR SEE OTHER SECTIONS FOR DETAILS • • AS REG2'D. PAVING-5EE CIVIL ENOINEERIN6 7A6 n DOOR SILL DETAIL 1 1/2" FOR ADDITIONAL INFORMATION SEE SECTION 2 THIS SHEET 6" R-Iq INSULATION A/ VAPOR BARRIER W SPLIT -FACE GMU (TURNED UP-SIDE- DO^IW AND GROUTED FULL W/ 5000 P51 GROUT ON POWERS STEEL 1-2-b" LINTEL. (FOLLOW MF6R5. SPECIFICATIONS) 1/4" SHIM SPACE CONCRETE SLAB W/ bxb-WI.4xWl.4 III MM OR FIBER MESH REINFORGIN6 OVER 6 MIL VAPOR BARRIER OVER P015ONED COMPACTED FILL ui 2-#5 CONTINUOUS FERIMETER FOOTING 3/4" = 1'—O" 26 6A. ROOF PANEL BY METAL BLDG. MF6R. R-10, 3" VINYL FACED INSULATION ROOF PURLIN STEEL FRAMING BY THE METAL BUILDING MANUFACTURER R-10, 3" VINYL FACED INSULATION GIRT5 AS SUPPLIED BY THE METAL BUILDING MANUFACTURER ANCHOR TO GMU WALL W/ 1/4" X 2" TAPCON5 AT 52" O.G. 1 5/4" X 4 1/2" ANODIZED BRONZE ALUMINUM STOREFRONT CONSTRUCTION W/ 1/4" TEMPERED OLA55 �{ESEPLANS ANO ANY CORRECT ONS pRESUBJECT SEE FOUNDATION SLAB SEE FOUNDATION PLAN TO REQUIRED ggCE �64Aa � ORDERRSTH ES IAWBEN ti COMPLY WITH'LL �PpL,C ELE COD GROUT FULL e a 1/2" 6YP5UM BOARD ON 1 5/5" a METAL STUDS AT Ib" O.G. W/ R-5 INSULATION BETWEEN ALUM' NUM' A I NDOA SEC,TI ON 1 1/2" = 1'-0" #5'5 EACH 5EE FOUNDATION PLAN ENDAALL SECTION 3/4" = 1'-0" EAVE TRIM BY MTL. BLD6. MFGR. VARIES 26 &A. STEEL PRE -FINISHED METAL RIBBED SIDING BOND BEAM COURSE W/ 1- #5 CONTINUOUS 5" GMU OR SPLIT FACE GMU W/1-#5 GROUTED CELL TO BOND BEAM. SEE PLANS FOR LOCATION. R-10, 3" VINYL FACED INSULATION ROOF PURLIN STEEL FRAMING BY THE METAL BUILDING MANUFACTURER R-10, 3" VINYL FACED INSULATION 61RT5 AS SUPPLIED BY THE METAL BUILDING MANUFACTURER - ANCHOR TO GMU WALL W/ 3/16" X TAPCON5 AT 32" O.G. #5 X 20" LON6 ONE PIECE HAIRPIN TO BE BENT AROUND ANCHOR BOLTS W/ 45 DEG. "V" BEND ---------- CONCRETE SLAB SEE FOUNDATION PLAN \ FLOOR LINES 100 -O„ \6RADE LINE 26 6A. ROOF PANEL BY METAL BLD6. MFOR. 12 1/2 #5'5 EACH WAY---T SEE FOUNDATION PLAN HALL SECTION 3/4" = 1'-0" REVISIONS: TOPOF 122'-01, O L_ GUTTER BY METAL L` BUILDING MANUFACTURER z° CC w a 0 tr � O O m 26 GA. STEEL PRE -FINISHED O a co METAL RIBBED SIDING c � � O d" U m DC ca �Qw cq it cq n` O � � cm !� • p 4" VIA. DOWNSPOUT O (TYPICAL OF ALL) (� � v U O • � LL! V O N cq ti C14 TOP OF CMU I10-O BOND BEAM COURSE W/ 1- #5 CONTINUOUS O N CCS +a FO a1 O v 4-4 N O O 8" GMU OR SPLIT FACE GMU z F+i W/1-#5 GROUTED GELL TO BOND BEAM. SEE PLANS FOR LOCATION. O O FLOOR LINE 100'-O" N O `GRADE LINE PROJECT NO. 10304 DATE: MARCH b, 2004 SHEET: A-4 PLUMBING NOTES 1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT 4" \ ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND 3"VTR 2 \ ORDINANCES. .4' i 2" J ` 1' 2. ALL MATERIALS SHALL BE NEW. L1 'i /i 2 i 2" %�4' 7-12-04 OWNER 3. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING i 2" i i ,ii 2" FCO CHANGES " � 31/2 HB CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE R i 2" 3?�` � 3"HD 2" ��� � i �r EWC 1/2" i WC1 2„/L1 I ! .� COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. �, L1 J i L1 4" , 4. REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR 3„ 3„ �`.� 2' WCI 1 I `\ 1/2" Ll� 3/4'�,, 1 „ 1„ FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE 1/2" EWC /2 FOR THE DURATION OF WORK. JS 3„ WCI 2"41 \`�`.�2•• 1/2" L /3/4���/j� C WC 1 ' WC 1 WC 1 5. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, 2„ 2'� �`.�T\ /, JS\� J � L1 � S1 � INSPECTION AND TESTS. 4' i i i �1/2" I I/ cq FCO i 2'1 ��. �2" WC1 � ✓V 6. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT DOCK � i LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. Si 1/2 1/2" 3/4 3„ L 1 %I 7. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO r AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION.. 1 2" / O HB 8. CONTRACTOR SHALL GUARANTEE ALL MATERIALS & WORKMANSHIP 2„ WC1 3„J�z `\Fq .00 FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR i I WC1 b cc FROM DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE EWC m a COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE o REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED. 2„ IWO 4 C TO SANITARY EWC q v d+ 9. PROVIDE 6 SETS OF SUBMITTALS FOR REVIEW BY ARCH/ENGR .� PRIOR TO PURCHASHING ANY EQUIPMENT OR MATERIALS. SUBMITTALS MANHOLE SANITARY I ETRIC WATER ISOMETRIC 4'• w SHALL INCLUDE ALL ITEMS AND MATERIALS SUPPLIED BY A CONTRACTOR. ANY EQUIPMENT OR MATERIALS INSTALLED WITHOUT NTS NTS O� VIEWED SUBMITTALS SHALL BE REMOVED AND REINSTALL AT IIS ECO ARCH/ENGR DISCRESTION WITH NO ADDITIONAL COMPENSATION TO ■ ■ ° , ■ ■ ■ • ■ , ■ ■ ■ ■ ■ ■ ■ . . it Op CONTRACTOR. O q 114A q GATE I ALVE ( TW�IkAL) _ 10. PROVIDE 2 SETS OF MAINTENANCE AND OPERATION MANUALS ON F.E. m ALL MECHANICAL EQUIPMENT OR SYSTEMS. — -� 0 11. VERIFY LOCATION, SIZE, INVERTS AND ALL EXISTING ° THERMAL EXPANSION CON ROL UTILITIES PRIOR TO BEGINNING CONSTRUCTION. ADVISE ENGINEER THERM-X-TROL MOD ST-2 V, 0 U OF ANY DISCREPANCIES. 10.3 GAL, 150 PSI. SEE PLAN F R SIZE 12. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE b CONTROL VALVES AND ACCESS PANELS. SEE PLAN FOR SIZE 13. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL CIS UNION{ DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. (TYPICAL) — — O 14. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS TEMPE ATURE AND PRESSURE � RELIE VALVE AS REQUIRED ■ PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING. ALL BY LO AO L CODE �mrj ACCESS PANELS MUST MATCH THE FINISH OF THE WALL IN WHICH IT C) cq SPECIFICATION. IS INSTALLED. WATER EATER (EWH) SEE 15. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL EQUIPMENT ROOMS. jI PIPE, FULL SIZE OF T&P DRAIN VALVE RELIEF VALVE 16. ALL HOT WATER PIPES UNDER SINKS SHALL BE WRAPPED AND INSULATED WITH HANDI-SHIELD WRAP OR EQUAL. 24 GAUGE GALVANIZED SHEETMETAL OR 60 MIL. IGH 17. INSULATE ALL HOT WATER LINES WITH:- 1" THICK IMPACT PLASTIC DRAINPA . • TERMINATE PIPING FIBERGLASS. PLATFORM AS NEEDED 2" ABOVE JAN SINK FOR INDIRECT 18. WATER PIPING AND FITTINGS SHALL BE SCHEDULE 40 "CPVC" CONNECTION WITH A RATING OF 100 PSI AT 180 DEG. F. 1" JApj�,UL�NK . 19. SOIL, WASTE, VENT, AND STORM PIPING SHALL BE SCHEDULE FINISHED FLOOR --- 8 40 PVC-DWV PIPE AND FITTINGS WITH NSF SEAL OF APPROVAL, ASTM ----- D2665-82 (PVC) AND ASTM D2661-84 (DWV), AS MANUFACTURED BY G. S. R. , CHARLOTTE PLASTIC PIPE & FOUNDRY CO., OR EQUAL. MAKE PVC JOINTS WITH PVC-DWV SOLVENT CEMENT, ASTM D2564-88 "UNI-WELD" 1200 UP TO 6" PIPE DIAMETER. A • 20. CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY W TER HEA ER DETAI FE FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS PRIOR TO wAREH U5E GONFERENGE BID. NTS EWH- G6J OFFIGE 5UPPUE5 122 OFFICE OFFICE E571MATOR 20 121 33 03 02 ° �r FIXTURE SCHEDULE: PA55A6E ■ O 24 GOV ED O 'I ro PROVIDE FIXTURES AS LISTED BELOW OR EQUAL FROM THE FOLLOWING ENTR r , MANUFACTURES: `J •� AMERICAN STANDARD, KOHLER. ELDER, SLOAN, ZURN, CHICAGO FAUCETS, T&S, 3„ D FILEGA5INET5 FE 101 U SPERZEL, OLSONITE, JOSAM, ACORN, ELKAY, HALSEY TAILOR, RHEEM, 2 U 11 LOCHINVAR, A. 0. SMITH, WADE, SMITH. TOILET O SED WORK we 1 6 T ESEPIANS ARD A' E,PRCP JS E c �, o O a� WC1 HANDICAPPED WATER CLOSET - WHITE AMER. STD. 2216. 143 ARESUWECTT06�NYCaR ECT�ONS L1 �o ,� •+.11-4 FLOOR MOUNTED, WITH TANK, `.12" ROUGH -IN EQUIREDBYFIELDINSP� TgRSTHAT U Y 1.6 GPF, ELONGATED O O N MAY BE NECESSARY IN RDERTO wc1 MEN IIS- -- Z � a OPEN FRONT, LESS COVER SPERZEL 50EWSSCH m COMPLY WIT4'A L Ai?F 9C .�E CODES. wAREH USE L 1 �-1 � uO1i o � i-1 rO� ii ■ OFFGE FCO OPEN OFFICE AREA • rn m m (� v �I L1 HANDICAPPED LAVATORY, WALL HUNG - WHITE AMER STD 0356.015 7 L1 EWC FCO o4 a FAUCET: 8 CENTERS, 5-3/8" SPOUT, WOMEN HB 1" 'N^ z 4" BLADE HANDLE CHICAGO 788-E3 wC1 3°F 4 ^ FLOOR CARRIER }( O Z o 4 w , WADE 400 rr, JS JANITOR'S SINK, 2' X2' FLOOR FIAT TSBC-6012 F.E. � o a S1 HANDICAPPED SINK 'SINGLE BOWL ELKAY LWR-2522-R TOILET 6- oho 8" CENTERS, 8" SPOUT, 4" LEVER HANDLE CHICAGO 201-317 2 ION uj Z-1 _1 _ w Z M F IV U EWC ELECTRIC WATER COOLER ELKAY EBFSA-8 EWC 1 BREAK = n � OFFICE OFFICE OFFIGE OFFIGE z g^� 5 PP IFS Ro OM 108 07 06 105 N ^o v HB HOSE BIBS CHICAGO 387-E27 0 � c W/ VACUUM BREAKER F,E. ELECT. / « yw� • • • • • ■ • ■ ■ • • • ■ ■ • ■ ■ • ■ ■ • (p 0 la WHA WATER HAMMER ARRESTER SMITH 5040 7 o 3 ❑ HB Q W "' a PRO.IEGT NO. 10504 TP TRAP SEAL PRIMER VALVE JOSAM 88250 r � DATE:MARGH 8,2004 HD HUB DRAIN - W/FUNNEL STRAINER JOSAM 30000-E3 V SHEET: FCO FLOOR CLEANOUT, ADJUSTABLE COLLAR, JOSAM 5837OA-2 BRONZE TOP / G P_ 1 ECO EXTERIOR CLEANOUT BRONZE BODY AND PLUG JOSAM 58490-7 EWH ELECTRIC WATER HEATER RHEEM 61VP20S m FLOOR PLAN PLUMBING 20 GAL, 4.5 KW, 240/1 VAC NORTH SCALE: 1/8'il'-0' A/C LEGEND : WS WALL SWITCH SD SMOKE DETECTOR OH HEAT DETECTOR (FIRE STAT) OT THERMOSTAT 1O KEYED NOTE: EF 1 EQUIPMENT TAG: (ex. EF-1) SUPPLY AIR DIRECTION —� RETURN AIR DIRECTION *> UNDER CUT DOOR 1" MIN UNLESS INDICATED ® INDICATES SUPPLY AIR INDICATES RETURN AIR ® INDICATES EXHAUST AIR CD GRILLE MARKER: INDICATES 12X12 TYPE "CD" GRILLE WITH 12"X12" 300 NECK, BALLANCE FOR 300 CFM. SUPPLY AIR GRILLE IN T—BAR ® CEILING SEE ARCHITECT'S REFLECTIVE CEILING PLAN ® SUPPLY AIR GRILLE SURFACE MOUNTED INTO CEILING TILE OR DRYWALL CEILING. ED WALL CAP DW DRYWELL SEE DETAIL FLEXIBLE DUCT: SIZE TO MATCH DIFFUSER NECK SIZE, UNLESS OTHERWISE INICATED. FLEX DUCT COLLAR W/OBD SPLITTER DAMPER 45 DEG TAP WITH DAMPER }� DUCT TRANSITION OPPOSED BLADE DAMPER (OBD) FIRE DAMPER WITH ACCESS DOOR HVAC KEYED NOTES: 1. PROVIDE AN 8" RND OUTSIDE AIR DUCT TO WALLCAP. 2. PROVIDE A 6" RND EXHAUST DUCT TO ROOFCAP. COMPLY %1VI ALL ApPL' CAULt. ^ NORTH SCALE: 1 /B' =1' -0' IN d Z Lno O N N n MNz O n� p N OvE XO Co < x O Q Ll m O O �Ld U M r zla U Z n gf`r i. M N 00 U Y W Z U00 M � REVISIONS: 7-12-04 OWNER CHANGES O tfJ N Ou r�r h=•I O q O (m cr0 4[1 cOD m O 0 � • O .d U Q G4 O •� i- 00 n\ O 1 O � O O � U w V O O cq GV LaE go I %/ i U G-I PRO.EGT NO. 10304 DATE: MARrH S, 2004 SHEET: M-1 MECHANICAL EQUIPMENT NOTES: 1. ALL MECHANICAL EQUIPMENT SHALL BE ARI & U.L. LISTED WHERE APPLICABLE AND RATED FOR THE REQUIRED SERVICE, PRESSURES, TEMPERATURES, AND SHALL BE PROVIDED WITH ALL NECESSARY TRANSFORMERS, SEALS, VALVES, CONNECTIONS, ETC. TO FUNCTION PROPERLY. 2. ALL INSULATION WILL HAVE FIRE/SMOKE RATING LESS THAN 25/50. 3. PROVIDE A MIN. OF 3' CLEARANCE IN FRONT OF ALL 120-240 VOLT RATED PANELS AND DISCONNECTS. PROVIDE ADEQUATE SIDE CLEARANCE PER NEC. 4. PROVIDE MOTOR STARTERS FOR ALL MOTORS. 5. PROVIDE IONIZATION TYPE AIR DUCT SMOKE DETECTORS WITH ACCESS DOORS WHERE INDICATED ON PLANS. ALL SMOKE DETECTORS SHALL BE BY ONE MANUFACTURE, COORDINATE VOLTAGE ETC. WITH ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM BEFORE ORDERING. UPON DETECTION, SMOKE DETECTORS SHALL SHUT DOWN" ASSOCIATED AIR MOVING EQUIPMENT AND ALL AIR MOVING EQUIPMENT SERVING THAT COMMON PLENUM. CONNECT SMOKE DETECTOR TO BUILDING CENTRAL FIRE ALARM SYSTEM. IF BUILDING DOES NOT HAVE A CENTRAL FIRE ALARM SYSTEM, PROVIDE REMOTE ANNUNCIATOR/TEST STATION WITH PIEZO ALERT AND LED, IN OCCUPIED AREA (PER NFPA 90A CH 4-4.4). SMOKE DETECTOR SHALL BE "SYSTEM SENSOR" - DH400ACDC WITH 21-390 ANNUNCIATOR OR EQUAL. 6. PROVIDE FLEXIBLE DUCT CONNECTORS, RATED AS REQUIRED, TO ALL FANS, A/C UNITS, OR MECHANICAL EQUIPMENT, EXCEPT FANS USED FOR GREASE EXHAUST. 7. PROVIDE VIBRATION ISOLATORS ON ALL MECHANICAL EQUIPMENT AS CALLED FOR IN THE SPECIFICATIONS. IF NOT SPECIFIED, AS RECOMMENDED BY MANUFACTURER FOR QUIET AND VIBRATION FREE OPERATION. 8. PROVIDE A MIN. OF 10' CLEARANCE BETWEEN O/A INTAKES AND VTR OR EXHAUST OPENINGS. 9. HVAC CONTRACTOR SHALL TEST AND BALANCE ALL MECHANICAL EQUIPMENT AND AIR DEVICES, EXTRACTORS, DAMPERS, A/C UNITS, FANS, ETC. TO PROVIDE THE DESIGN QUANTITIES AS SHOWN ON THE PLANS OR SCHEDULES. 10. TEST AND BALANCE SHALL NOT BE STARTED UNLESS FILTERS ARE CLEAN. ANY BALANCING WORK COMPLETED WITH DIRTY FILTERS WILL HAVE TO BE REDONE. PRIOR TO STARTING BALANCING OPEN ALL DAMPERS IN DUCT SYSTEM AND AT GRILLS. ALL FLOW ADJUSTMENTS SHALL BE MADE AT THE BRANCH TAKEOFF, NOT AT THE GRILLS. ALL AIR FLOWS LISTED IN REPORT SHALL BE THE FINAL READINGS AFTER ALL ADJUSTMENTS ARE MADE. AFTER ALL AIR FLOWS ARE ADJUSTED THE TEST AND BALANCE CONTRACTOR SHALL TAKE AND RECORD THE FOLLOWING TEMPERATURES, PRESSURES, AND AMPERAGES: a) EVAPORATOR ENTERING AIR TEMPERATURE b) EVAPORATOR LEAVING AIR TEMPERATURE c) CONDENSER LEAVING AIR TEMPERATURE d) AMBIENT AIR TEMPERATURE e) REFRIGERANT SUCTION PRESSURE f) REFRIGERANT DISCHARGE PRESSURE g) UNIT VOLTAGE h) COMPRESSOR AMPERAGE 1) EVAPORATOR FAN MOTOR AMPERAGE j) CONDENSER FAN MOTOR AMPERAGE 11. RUN CONDENSATE DRAINS TO DRYWELL, AS REQUIRED. CONDENSATE DRAINS SHALL BE A MINIMUM OF 3/4". CONDENSATE DRAINS SHALL BE SCHEDULE 40 PVC, WITH 1/2" ARMAFLEX INSULATION. 12. MOUNT ALL EQUIPMENT FOR WIND LOADS AND MOUNTING HEIGHTS AS REQUIRED BY LOCAL CODES. 13. ALL PIPING AND DUCTWORK SHALL BE SLEEVED THRU WALLS, BEAMS, SLABS, ETC, AS REQUIRED AND COORDINATED WITH THE STRUCTURAL ENGINEER. PROVIDE NECESSARY TRANSITIONS AS REQUIRED FOR DUCTWORK INSTALLATION. 14. CONTRACTOR WILL PROTECT THE AIR-CONDITIONING UNITS AND DUCTWORK IN THE FOLLOWING MANNER. PRE -FILTER ALL RETURN AIR GRILLES WITH ROLL TYPE FILTER MEDIA AND REPLACE IT AS NEEDED THROUGHOUT THE CONSTRUCTION PERIOD. EQUIPMENT MUST NOT BE STARTED FOR ANY PURPOSE UNTIL THE DRYWALL SANDING, ETC. IS COMPLETED. ONCE DRYWALL SANDING IS COMPLETED, THE UNITS MAY BE STARTED ONCE THE ABOVE PRE -FILTERING IS COMPLETED. COORDINATION NOTES: 1. A/C CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE HIS WORK FOR SIZE, LOCATION, CLEARANCE, ACCESS AND ELECTRICAL CHARACTERISTICS WITH ALL OTHER TRADES AND TO PROVIDE SHOP DRAWINGS,TO THE ENGINEER FOR REVIEW BEFORE INSTALLATION OF DUCTWORK OR EQUIPMENT. SHOP DRAWING WILL INCLUDE BEAM OR STRUCTURE ELEVATION & REQUIRED EQUIPMENT ACCESS AREAS. 2. WALL, ROOF, AND CEILING OPENINGS INDICATED ON 'CONTRACTOR DRAWINGS'ARE NOMINAL DIMENSIONS ONLY AND ALL DUCT, PIPE OR EQUIPMENT PENETRATIONS SHALL BE SLEEVED AND FIRE RATED AS REQUIRED, ADJUST OPENINGS 3. COORDINATE LOCATION OF CEILING DIFFUSERS, GRILLES AND REGISTERS IN THE FIELD WITH LIGHTS, SPRINKLERS AND ARCHITECTURAL ELEMENTS. 4. COORDINATE LOCATION OF A/C UNITS, THERMOSTATS, FANS AND DUCTWORK WITH BUILDING STRUCTURE AND OTHER TRADES SO THAT NO INTERFERENCES OCCUR. 5. IN GENERAL, DUCT OFFSETS HAVE NOT BEEN SHOWN. A/C CONTRACTOR TO COORDINATE THESE AS REQUIRED. 6. MECHANICAL PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION WITH ARCH. PLUMBING, ELECTRICAL AND STRUCTURAL PLANS. DUCT AND PIPING OFFSETS, BENDS AND TRANSITIONS WILL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. GENERAL NOTES: 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, EQUIPMENT, ACCESS PANELS, CONTROL SYSTEMS, DEVICES, PERMITS AND SERVICES NECESSARY FOR FURNISHING AND INSTALLING OF A COMPLETE SERVICEABLE MECHANICAL SYSTEM. 2. ALL MECHANICAL SYSTEMS ARE TO BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE SECTIONS OF THE NFPA STANDARDS, ANSI STANDARDS, THE LOCAL BUILDING CODE, PLANS AND SPECIFICATIONS. 3. ALL MATERIALS SHALL BE NEW (UNLESS OTHERWISE INDICATED) AND ANY DAMAGED EQUIPMENT SHALL BE REPLACED. 4. CONTRACTOR WILL WARRANTY ALL MECHANICAL SYSTEMS, EQUIPMENT, PARTS AND LABOR FOR A PERIOD OF ONE (1) YEAR AFTER C.O. 5. PROVIDE 6 SETS OF SUBMITTALS FOR REVIEW BY ARCH/ENGR PRIOR TO PURCHASING ANY EQUIPMENT OR MATERIALS. SUBMITTALS SHALL INCLUDE ALL ITEMS AND MATERIALS SUPPLIED BY CONTRACTOR. SUBMITTALS SHALL HAVE A SUMMARY SHEET SHOWING ALL SCHEDULED INFORMATION. ANY EQUIPMENT OR MATERIALS INSTALLED WITHOUT REVIEWED SUBMITTALS SHALL BE REMOVED AND REINSTALL AT ARCH/ENGR DISCRETION WITH NO ADDITIONAL COMPENSATION TO CONTRACTOR. 6. PROVIDE 2 SETS OF MAINTENANCE AND OPERATION MANUALS ON ALL MECHANICAL EQUIPMENT OR SYSTEMS. 7. ALL LOUVERS, GRILLES, PIPING, ETC. SHALL BE PAINTED TO MATCH SURROUNDING COLOR AND TEXTURES AS REQUIRED BY ARCHITECT. VERIFY COLOR AND TEXTURE WITH ARCHITECT. PAINT ALL EXPOSED MECHANICAL EQUIPMENT WITH BENJAMIN MOORE EPDXY ENAMEL 182. 8. ALL OPENINGS IN BUILDING STRUCTURE, FOR DUCTWORK, PIPING, ETC. TO BE 1/2" LARGER (ON ALL SIDES) THEN THE OUTSIDE DIMENSIONS. FILL VOIDS WITH FIRE RETARDANT SILICONE FOAM (I.E. CHASE -FOAM CTC PR-855 BY CHASE TECHNOLOGY CORP.). DUCTWORK & ACCESSORIES NOTES : 1. ALL DUCTWORK SHALL BE AS FOLLOWS OR APPROVED EQUAL: a) SUPPLY - MANVILLE SUPERDUCT 1-1/2" 3/4 LB FIBERGLASS DUCTBOARD R=6.0. b) RETURN - MANVILLE SUPERDUCT 1-1/2" 3/4 LB FIBERGLASS DUCTBOARD R=6.0. c) FLEX DUCT - THERMAFLEX G-KM R=6.0. d) O/A - GALV. SHEETMETAL W/ 1" 3/4 LB WRAP e) EXHAUST - GALV. SHEETMETAL 2. ASSEMBLE, INSTALL, AND SEAL DUCTWORK IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARD". UNLESS OTHERWISE NOTED ON PLANS CONSTRUCT DUCTWORK TO 2" DUCT CLASS, SEAL CLASS "B", AND LEAKAGE CLASS 12. 3. SEAL ALL SHEETMETAL DUCTS JOINTS WITH RCD #8 MASTIC. 4. MAKE JOINTS FOR DUCT WRAP AND DUCTBOARD WITH GLASS FABRIC AND VAPOR BARRIER COATING TO 30 MILL DRY FILM THICKNESS, RCD #9. 5. CONTRACTOR SHALL PROTECT ALL FIBERGLASS INSULATION PRODUCTS FROM DAMAGE. INSULATION PRODUCTS SHALL NOT BE ALLOWED TO GET WET. INSULATION DAMAGED AS A RESULT OF MOISTURE, VANDALISM, OR CONSTRUCTION TRAFFIC SHALL BE REPLACED. 6. PROVIDE RUSKIN "DIBD2" TYPE "B" FIRE DAMPERS (UL 555 DYNAMIC RATING) WITH ACCESS DOORS WHERE INDICATED ON PLANS. 7. USE RADIUS RECTANGULAR FITTINGS OR TURNING VANES IN ALL SUPPLY DUCT ELBOWS, CONICAL BRANCH TAKE -OFFS, SPLITTER DAMPERS WHERE INDICATED ON DRAWINGS AND VOLUME CONTROL EXTRACTORS IN ALL BRANCH DUCTS OR DIFFUSER CONNECTIONS. 8. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. 9. PLANS ARE DIAGRAMMATIC. IN GENERAL DUCT OFFSETS HAVE NOT BEEN SHOWN. A/C CONTRACTOR SHALL COORDINATE THESE AS REQUIRED WITH BUILDING STRUCTURE AND OTHER TRADES. 10. TERMINAL AIR DISTRIBUTION DEVICES SHALL BE AS FOLLOWS OR APPROVED EQUAL: a) CD CEILING DIFFUSER MODEL TDCA-AA, 24X24 MODULE TYPE 3 BORDER, WITH SQUARE OR ROUND NECK. PROVIDE 4-WAY AIR PATTERNS UNLESS OTHERWISE SHOWN ON PLANS. b) RAG RETURN AIR GRILLE MODEL 350FL. 11. PAINT DUCTWORK VISIBLE BEHIND AIR DISTRIBUTION DEVICES MATTE BLACK. r REq V THESE PLANS AND ALL p %pouD WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INVECTOR3 THAT MAY BE NECESSARY IN ORDIR TO COMPLY Wrffi f.:.L APPLIUME COM, SPLIT SYSTEM SCHEDULE MARK AH/CU-1 AH/CU-2 SYSTEM TYPE CLG/ELEC HTG CLG/ELEC HTG AREA SERVED SEE SEE PLANS PLANS AIR HANDLER DATA: MANUFACTURER TRANE TRANE MODEL NO. TWEO6OC TWE060C WEIGHT (LBS) 200 200 CABINET TYPE (VERT/HORIZ) VERT VERT CFM TOTAL 1700 1775 CFM 0. A. 250 200 E. S. P. ( " W. G. ) .5 .5 H. P. /F. L. A. . 50/5. 9 50/5. 9 RPM ( SPEED) ( MED) (MED) ELECTRIC HEATER KW 7.2 7.2 HEATER STAGES 1 1 HEAT LOCATION (DUCT/INT.) INTERNAL INTERNAL VOLTAGE (V/PH/60) 208/1/60 208/1/60 POWER CONN. (SINGLE/MULTI) SINGLE SINGLE MAX FUSE 60 60 CONDENSING UNIT DATA: MANUFACTURER TRANE TRANE ` MODEL NO. TTRO60C TTRO60C WEIGHT (LBS) 260 260 COMP. QTY 1 1 COMP. F. L. A. EA. 29. 1 29.1 COMP. L. R. A. EA. 141.0 141.0 TY CONDQFAN H. P. ( EA) 25 .25 COND FAN F. L. A. ( EA) 1.9 1. 9 VOLTAGE (V/PH/60) 208/1/60 208/1/60 MCA 38.0 38.0 MAX FUSE 60 60 SYSTEM DATA 95 DEG F AMB : TOTAL COOLING (TMBH) 58.2 58.2 SENSIBLE CAPACITY (SMBH) 39.2 39.2 ENT. AIR TEMP. (F) (DB WB) 80 67 80/67 COMPRESSOR STAGES % 0/100 0/100 HEATPUMP CAPACITY �MBH) - - A. R. I. SYSTEM EFFICIENCIES: SEER/HSPF 10. 20/1. 0 10. 20/1. 0 EER/IPLV/COP - - REMARKS: SEE BELOW j SEE BELOW SPLIT SYSTEM NOTES: 1. SELECTION BASED ON TRANE, PROVIDE EQUAL BY CARRIER, MCQUAY, YORK, RHEEM, OR RUUD. 2. ALL UNITS MUST BE UL LISTED AND ARI CERTIFIED. 3. PROVIDE LIQUID LINE FILTER -DRYER SIGHT -GLASS AND SOLENOID VALVE. 4. PROVIDE SERVICE VALVES ON SUCTION AND LIQUID LINES. 5. PROVIDE ONE YEAR WARRANTY ON UNIT, 5 YEAR WARRANTY ON COMPRESSOR. 6. PROVIDE BUILT-IN FACTORY WIRED UL ELECTRIC HEATER W/HEATER CONTROL PACKAGE. 7. PROVIDE PROPER VIBRATION ISOLATION AS PER DRAWINGS AND SPECIFICATION, IF NOT SHOWN, AS PER MANUFACTURER'S RECOMMENDATION. B. SIZE AND RUN COPPER REFRIGERANT PIPING AS PER MANUFACTURERS PUBLISHED RECOMMENDATIONS TO PROVIDE LISTED SENSIBLE AND TOTAL MBH. 9. PROVIDE AUX. DRAIN PAN AND A/C CONDENSATE DRAIN LINES WITH A TRAP AND CLEANOUT. 10. PROVIDE 3/8" THICK ARMAFLEX FIRE RETARDANT PIPING INSULATION ON A/C CONDENSATE LINES, 1/2" THICK ON REFRIGERANT SUCTION LINES 2-5/8" AND SMALLER, AND 3/4" ON ALL LINES LARGER THAN 2-5/8". PROVIDE AN ALUMINUM JACKET TO PROTECT THE INSULATION ON ALL PIPING OUTDOORS AND IN MECHANICAL ROOMS. OVERLAP END OF JACKET BY THREE INCHES AND SECURE WITH STAINLESS STEEL BANDING. 11. PROVIDE TWO SETS OF 1" 40% FILTERS TRI-DIM ES60M THROW AWAY FILTERS (800 937-1450). 12. E. S. P. DOES NOT INCLUDE COIL OR CABINET LOSSES. 13. UNLESS OTHERWISE NOTED CAPACITIES AND EFFICIENCIES ARE AT ARI CONDITIONS: 14. COORDINATE WITH ELECTRICAL CONTRACTOR BEFORE BIDDING OR ORDERING ANY EQUIPMENT. 15. SEE GENERAL, AIR CONDITIONING, DUCTWORK, AND COORDINATION NOTES FOR OTHER FIELD SUPPLIED ITEMS. 16. PROVIDE A/C UNITS WITH HEATING AND COOLING THERMOSTAT WITH FAN ON -OFF -AUTO SWITCH. . SET STAT FOR FAN IN AUTO MODE. FAN SHALL NOT RUN UNLESS THE COMPRESSOR OR HEATER IS ON. FAN SCHEDULE 2 MARK EF-1, 2, 3, 4 QUANITY 4 TYPE CEILING SERVICE RESTROOMS MANUFACTURE GREENHECK MODEL NO. SP-6 WEIGHT 10 AIR DATA: C. F. M. 75 S. P. .25 RPM 1500 B. H. P. ( WATTS) (40) TIP SPEED - SONES 3.4 MOTOR DATA: DRIVE DIRECT R. P. M. 1500 H. P. ( WATTS) (40) VOLT-PH-HZ 120/1/60 REMARKS 1, 2, 3, 4 FAN NOTES 1. SELECTION BASED ON GREENHECK, PROVIDE EQUAL BY PENN, LORAN COOK, OR ACME. 2. PROVIDE MOTOR STARTERS AND ALL ASSOCIATED CONTROLS ON ALL FANS. 3. PROVIDE BACK DRAFT DAMPER FOR ALL EXHAUST. 4. SWITCH WITH LIGHTS. REVISIONS: 7-12-04 OWNER CHANGES UZ ►fZ L` cal m O O Cm d0 co Y m O Q 0 0 r"4 0 O .d U A Gf � \ a eq eq Sn ^iW � crz O 1 4-a V O � U w • � CCi V O cq 0 cz O O .,r O '~ U dry it 0 QS z .I Z m 0 al 00 0) CIS N n 4k o `� 0 M 0 i V x o'a W 0 Imo W0 M z�l� Z Zr4 gnr y O U V Svc w CK Q Z o W PROJPGT NO. 10504 0DATE: MARC44 6, 2004 SHEET: ���' M-2 REVISIONS: OUTSIDE AIR VOLUME DAMPER RETURN AIR DUCT FLEXIBLE CONNECTION FIN. FLOOR ' C' CHANNEL SUPPORT AS REQ' D SMOKE DETECTOR FIN. CEILING SUPPLY AIR DUCT FLEXIBLE CONNECTION - AIR HANDLING UNIT — R/A PLENUM BASE VIBRATION ISOLATION AIR HANDLING UNIT DETAIL N. T. S. AHU-VI #11 WIRE -''---" .TAL tK WHITE CEILING GRILL NOTES: 1.- PROVIDE BACKDRAFT DAMPER 2.- SUPPORT FAN FROM STRUCTURE CABINET CEILING FAN DETAIL N. T. S. FANCEIL3 SAMPLING TUBE AIRFLOW INSULATED ACCESS PANEL SMOKE DETECTOR ENSURE SMOKE DETECTOR HOUSING BAFFLE IS IN PLACE REPLACE HOUSING COVER PROMPTLY FOLLOWING SERVICING TO AVOID FALSE ALARMS NSULATION —DISCHARGE TUBE \-NEOPRENE GASKET — SMOKEDETECTOR HOUSING PROVIDE ACCESS FOR REMOVING SAMPLING TUBES. T__ NOTES: 1. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTION. 2. COORDINATE VOLTAGE AND TYPE WITH ELECTRICAL AND FIRE ALARM CONTRACTORS. 3. SAMPLING TUBE MUST BE INSTALLED ACROSS GREATEST DUCT DIMENSION. DUCT SMOKE DETECTOR DETAIL NTS SDET-1 5 M-4 NOTE: 1. ALL REFRIGERANT PIPE AND INSULATION SHALL BE INSTALLED SECTION BY SECTION AT THE SAME TIME AND IN CONJUNCTION WITH THE INSTALLATION OF THE PVC REFRIGERANT PIPE CHASE. 2. ALL REFRIGERANT PIPING INSTALLED IN THE PVC CHASE SHALL BE CAPPED AND PRESSURE TESTED ACCORDING TO SPECIFICATIONS PRIOR TO INSTALLATION OF CONCRETE SLAB. 3. ANCHOR CONDENSING UNIT TO CONCRETE SLAB AS FOLLOWS. PROVIDE ONE 1-1/2" 16 GA GALV. STEEL STRAP EVERY 12"O.C. SECURE STRAP TO UNIT WITH WITH (2) 3/4"#10 SHEETMETAL SCREWS. SECURE STRAP TO CONCRETE SLAB WITH RED HEADS. - CONDENSING UNIT (TO BE INSTALLED ON 1" THICK NEOPRENE ISO- LATION PADS) FLEXIBLE SEAL TIGHT ATTACHED TO ELEC- TRICAL CONDUIT ELECTRICAL CONDUIT FOR LOW VOLTAGE CONTROL WIRING �\ GRADE - PIPE CHART SUCTION PIPE SIZE PVC REFRIGERANT PIPE CHASE SIZE 1-7 8 TO 2-5 8" 6" 3-16 TO 4-1 6 8 CONCRETE SLAB REFRIGERANT PIPES HARD -DRAWN COPPER. PVC REFRIGERANT PIPE CHASE.CUT OFF 1" ABOVE GRADE AND SEAL ENDS WITH WIRE MESH SCREEN CONDENSING UNIT PIPING DETAIL N. T. S. CU-PC-WM ANNEL DUCT TAIL IIMIVUIIYU ML I MIL NOTE: ALL STRAP SHALL BE A MINIMUM OF 1-1/2,26 GA GALVINIZED STEEL. WITH A 6 FT MAXIMUM SPACING. METHODS OF HANGING DUCTS N. T. S. HANCDUCT 2 M-4 MIN. 4" HIGH VENT MIN MAX SEE SPECIFICATIONS FOR PIPE TYPE AND INSULATION REQUIREMENTS A/C UNIT COIL CONDENSATE DRAIN PAN EXTEND CONDENSATE LINE FULL SIZE FROM UNIT CONDENSATE DRAIN CONNECTION (3/4" MINIMUM) CLEANOUT WITH THREADED PIPE CAP SATE TRAP DETAIL NOTE: ALL STRAP SHALL BE A MINIMUM OF 1-1/2", 26 GA GALVINIZED STEEL. HANGER WIRE SHALL BE A MINIMUM OF 22 GA. SPIN -IN W/ MANUAL DAMPER & AIR SCOOP RIGID AIR DUCT: SEE "METHODS OF HANGING DUCTS" FOR REQUIREMENTS FIN. CILING-' INSTALL STAINLESS STEEL DUCT CLAMPS ON BOTH INNER AND OUTER JACKETS. SEAL INNER JACKET AIR TIGHT WITH MASTIC. NYLON DUCT CLAMPS MAY BE USED IN NON PLENUM AREAS. GUNU-IKZ HANGER WIRE OR STRAP 10' -0" MAX DISTANCE BETWEEN SUPPORTS. MAX. SAG 1/2" PER FOOT OF SUPPORT SPACING. 1-1/2" GALV.STEEL BAND CLAMP TO MATCH DUCT DIAMETER AIR DIFFUSER FLEXIBLE DUCT DETAIL N. T. C. FLEXDUCT y THESE PLANS A,NO ALL RpOPOSED WORK ARE SUBJECT TO ANY CCR�ECTIONS REQUIRED BY FIELD II4SPECTORS THAT MAYBE NECEkkily IN ORDER TO g MCOMPLY V11TH ALL kppLICr3LE CODES. INSULATED FLEXIBLE DUCT 3 M-4 �24" DIAMETER MIN. CORROGATED BLACK PLASTIC PIPE o p° p p pp n Epp .pl nn. pnn pn pin n� pn v n' p � la la n p p �n pn � o , 0, p p laa17 np ppp n n pnn p IQp �n a in p°n p pnn pn n p la a n n n n& p° p p Vlp n pp op n pnn pn pn n p4 n p p� n p �n pn n n p n 'a p 0 1C,10 p np lapIDla n n n A n n n� DRYWELL DETAIL N. T. S. DRYWELL4 INSULATED PLENUM BOX ALTERNATE FOR LOW CLEARANCE N. T. S SUSPENDED T-BAR CEILING GRID LAY -IN ACUSTICAL CEILING TILE ��=/ SUPPLY AIR GRILLE FLOW 3/4" CRUSHED ROCK INSULATED DUCT M-4 6' SHEETMETAL EXTENSION COLLAR 26 GAUGE COLLAR SUPPLY AIR GRILLE e N. T. S. CD-1 FM-4 o >1� GV a w r O O (m M C m ° Q U a e� °m m • _ � b14 U = m ti DC A rm, cq \ O 1 pn O � 0 4a da � U O C� (3) rr(1) cq O r•4 r tr O ad • �, �° O Z 0 a 0 'Lno o 4s m m � 44 ., n Lv') MIlZ z C;o p N r� oxo O 0 Q W uiU M H zla U Z h L z w�v r^ v, U Z O 0 Q�° a i` W PROXOT NO. 10904 r � DATE: MARCH 8, 2004 �•! SHEET: �1+� M-3 SYMBOLS 0 FLUORESCENT LIGHTING FIXTURE - CEILING MOUNTED O FLUORESCENT, INCANDESCENT ❑R HID DOWNLIGHTING FIXTURE - CLG. MOUNTED EMERGENCY BATTERY EXIT LIGHTING FIXTURE UNIT �1 EMERGENCY BATTERY UNIT LIGHTING FIXTURE - WALL MOUNTED N SINGLE POLE TOGGLE SWITCH - MOUNTED 42' AFF TO CENTERLINE UNLESS ❑THERWISE NOTED (3) 3 WAY DUPLEX RECEPTACLE - MOUNTED 18' AFF TO CENTERLINE UNLESS NOTED ❑THERWISE (GFI) GROUND FAULT INTERRUPTING (REF) REFRIGERATOR (WP) WEATHERPROOF DOUBLE DUPLEX RECEPTACLE - MOUNTED 18' AFF TO CENTERLINE UNLESS NOTED OTHERWISE DUPLEX RECEPTACLE - MOUNTED 6' ABOVE COUNTER BACKSPLASH UNLESS NOTED ❑THERWISE D COMMUNICATIONS OUTLET - MOUNTED 18' AFF TO C, L. U. N. O. TYPICAL - STUB 3/4' CONDUIT TO TELEPHONE BOARD. PROVIDE 2 GANG BOX WITH ONE GANG RING (TYPICAL). PROVIDE CEILING J-BOX AND CONNECT TO AND INSTALL POWER/DATA/COMMUNICATIONS POLE SUPPLIED BY FURNITURE MANUFACTURER. CONTRACTOR SHALL VERIFY AND COORDINATE EXACT LOCATION WITH OWNER'S FURNITURE PARTITIONS IN FIELD AND MAKE FINAL CONNECTIONS TO OWNERS' EQUIPMENT AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. PROVIDE FLEX LENGTHS AS NECESSARY FOR FINAL CONNECTIONS. BPIO SPECIAL OUTLET FOR MODULAR FURNITURE - MOUNTED 18" AFF UNLESS OTHERWISE NOTED. NOTED. CONTRACTOR SHALL VERIFY AND COORDINATE EXACT LOCATION WITH OWNER'S FURNITURE PARTITIONS IN FIELD AND MAKE FINAL CONNECTIONS TO OWNERS' EQUIPMENT AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. PROVIDE FLEX LENGTHS AS NECESSARY FOR FINAL CONNECTIONS. MOTOR 2] DISCONNECT SWITCH OJ JUNCTION BOX C� TERMINAL CABINET ELECTRICAL PANEL A INDICATES DESIGNATION 1 Q SEE NOTE SYMBOL �\ SOLID LINE INDICATES EQUIPMENT ON COMMON CIRCUIT AND/OR CONTROLLED BY COMMON SWITCH. EACH CIRCUIT SHALL CONSIST OF A PHASE CONDUCTOR, NEUTRAL AND GROUND CONDUCTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE NECESSARY SWITCH LEGS IN CONDUIT TO ACHIEVE SWITCHING INDICATED ON PLANS. ELECTRICAL CONTRACTOR MAY COMBINE CIRCUITS INT❑ A COMMON HOMERUN CONSISTING OF A COMMON NEUTRAL AND GROUND CONDUCTOR AND THREE (3) PHASE CONDUCTORS (A, B, AND C PHASE). DOTTED LINE INDICATES EQUIPMENT ON A COMMON CIRCUIT BUT NOT CONTROLLED ON SAME SWITCH DEVICE. THE FOLLOWING ABBREVIATION NEXT TO A SYMBOL INDICATESt E EXISTING ER EXISTING TO BE REMOVED EL EXISTING TO BE RELOCATED EP EXISTING TO BE REPLACED RE/CKT REUSE EXISTING CIRCUIT RAI REMAIN AS IS NOTE, NOT ALL SYMBOLS MAY HE USED. ELECTRICAL_ KEYED NOTES: 1. PROVIDE 30A/2P FUSIBLE DISCONNECT SWITCH AT UNIT (NEMA 1) WITH DE FUSES SIZED PER EQUIPMENT MANUFACTURES RECOMMENDATIONS. BRANCH WIRING SHALL BE 2#12, 1#12 GND.-1/2"C. 2. PROVIDE 60A/2P FUSIBLE DISCONNECT SWITCH AT UNIT (NEMA 1) WITH DE FUSES SIZED PER EQUIPMENT MANUFACTURES RECOMMENDATIONS. BRANCH WIRING SHALL BE 2#6, 1#10 GND. -1"C. 3. PROVIDE 6OA/2P FUSIBLE DISCONNECT SWITCH AT UNIT (NEMA 3R) WITH DE FUSES SIZED PER EQUIPMENT MANUFACTURES RECOMMENDATIONS. BRANCH WIRING SHALL BE (60A/2P) , 2#6, 1 #10 GND. -1" C. PROVIDE WATER PROOF, GFI SERVICE RECEPTICAL AS INDICATED ON PLANS. ARE SUBJECT TC f Iaf CO�IECTIons REQUIRED DY Flcl,rj I E ECTORSTHAT MAY EE RECESlk.�Y IN ORDER TO 0 ALL h; s"L`" N' CODES. COMPLY Vv'I m FLOOR PLAN - POWER AND DATA NORTH SCALE: 1/8"=V -0" f=7;-QVAWE2 0 7-12-04 OWNER CHANGES O L` 14 �i O o q O rn CO 4[1 coo O v GYM O m 0 O 4 as 1-* CO .3 O O 4-5 w O rr� W O cq cq (D 0 O rl o CIS -- Pr, 0 d rn w U V w� Z m z ul o 0O 0 In U G4 w 1, I rl N Y Izn Ova O x� U. L) x o a W 4 Imo W� M L61 zla U Z zr--Ll g^ir ^ 0 w -� N U V Svc / p� L z z �a0 =V < I 1 I PROXOT NO. 10304 r I� �J DATE: MARCH 8, 2004 V 6 4EET: �� E-1 LIGHTING FIXTURE SCHEDULE MARK LAMP DATA DESCRIPTION FIXTURE MODEL NUMBER MOUNT VOLT NOTES #1 QTY TYPE MANUFACTURER CATALOG NUMBER A2 2 F32-TB 2'X4' RECESS FLUOR ACRYLIC LITHONIA 2GTB-2-32-A12125-120-GLR REC GRID 120 A3 3 F32-TB 2'X4' RECESS FLUOR ACRYLIC LITHONIA 2GTB-3-32-A12125-120-GLR REC GRID 120 C 2 F34CW T8 4' FLUORESCENT INDUSTRIAL LITHONIA EJ-2-32-120-HC CHAIN 120 D 1 32TRT FLUORESCENT - DOWNLIGHT LITHONIA LGFV-32TRT-7SB-T73-120 SURF 120 5 F 1 100 M CUTOFF WALL MOUNTED MINI AREA LITHONIA TWAC-IOOM-120 WALL 120 1 L 1 40OW MH LOW BAY WIDE DISTRIBUTION LITHONIA TXS-40OM-A30-208 HOOK 240 W 1 250 MV WALL MOUNTED FLOOD LITHONIA TWH-250H-208 WALL 240 X INC INC UNIVERSAL LED EMERGENCY EXIT LITHONIA LQMSW3REL UNIVERSAL 120 2.3 BU INC INC EMERGENCY BATTERY UNIT LITHONIA 16ELM2 UNIVERSAL 120 2.3.4 LIGHTING FIXTURE NOTES: 1. GENERAL SCHEDULE NOTES (APPLIES TO ALL FIXTURES): A) CONTRACTOR SHALL CORRDINATE FIXTURE MOUNTING WITH ARCHITECTURAL REFLECTED CEILING PLAN(S) AND SHALL PROVIDE FIXTUREMOUNTING AS REQUIRED TO MATCH CEILING TYPE. B) ALL FIXTURES BALLASTS SHALL BE HIGH POWER FACTOR TYPE. C) ALL FLUORESCENT BALLASTS SHALL BE ENERGY SAVING TYPE. D) ALL ELECTRICAL FIXTURES MUST BE INDEPENDENTLY SUPPORTED OF CEILING GRID. 2. FIXTURES TO BE PROVIDED WITH INTEGRAL EMERGENCY BATTERY BACK-UP. 3. FIXTURES SHALL BE CONNECTED TO CONSTANT NORMAL ROOMLIGHTING BRANCH CIRCUIT OF AREA SERVED (1,e, LOAD SIDE OF BREAKER, LINE SIDE OF ANY SWITCHING/CONTROLLING DEVICES). 4. FIXTURE TO BE WALL MOUNTED 7'-B" AFF TO TOP. 5. FIXTURE SHALL BE UL LISTED FOR WET LOCATIONS. ARE SUBJECT TO ANY CORRECTIONS REQUIRED BYRELDLNl LJ ECTORSTHAT (T FLOOR PLAN - LIGHTING K L V 10 1 V I I MAY BE NECESSARY IN ORDER TO NORTH SCALE: 1/8"=I' -O" COMPLY WITK ALL APPLICABLE CODES: dY zm 0 'too 0 u1 OI W 0 w 1 1 / R N Y V "Iz Il 4N C Y N 0vm X O Ir (3 ~ O Q W V_ 0 0m W W (gM� zl< U_ z Zr� grl� IV1p 0 V IL a W Z Z c1 0 0 Q'° (L�` V REVISIONS: 5-18-04 BLDG DEPT COMMENTS n 7-12-04 OWNER 0 cd 1 A n O z 0 54 V w w ru PROXOT NO. 10504 DATE: MAR H 8, 2004 SHEET: E-2 REVISIONS: 4'X8' PLYWOOD TELEPHONE BOARD #6 CU GND TO NEAREST BLDG GND. 2-3" CONDUIT, COORDINATE ROUTING WITH LOCAL TELEPHONE COMPANY TELEPHONE RISER (TYP TELEPHONE COORDINATION NOTE: CONTRACTOR SHALL CONTACT TELEPHONE COMPANY PERSONNEL AS NECESSARY FOR NEW SERVICES COORDINATION. CONTRACTOR SHALL OBTAIN TELEPHONE CO. REQUIREMENTS AND BE RESPONSIBLE FOR ALL WORK NECESSARY TO INSTALL NEW TELEPHONE SERVICES. CONTRACTOR SHALL COORDINATE COMPLETE LAYOUT AND LOCATIONS OF TELEPHONE COMPANY SERVICE PEDESTALS WITH LOCAL TELEPHONE COMPANY AS NECESSARY FOR A COMPLETE AND OPERABLE SYSTEM. CONTRACTOR SHALL PROVIDE ALL INFORMATION REQUIRED BY THE TELEPHONE COMPANY, INCLUDING ADDRESS(ES) AND LEGAL DESCRIPTIONS, FOR THE TELEPHONE COMPANY'S EASEMENT PROCUREMENT NEEDS. TELEPHONE PEDESTAL LOCATIONS AND QUANTITIES AS DETERMINED BY LOCAL TELEPHONE COMPANY. CONTRACTOR SHALL VERIFY AND COORDINATE EXACT LOCATIONS AND QUANTITIES OF ALL SERVICE PEDESTALS WITH LOCAL TELEPHONE COMPANY PRIOR TO INSTALLATION OF TELEPHONE SERVICE CONDUCTORS. ELECTRICAL SPECIFICATIONS 1. DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR A COMPLETE AND ACCEPTABLE WORKING INSTALLATION. 2. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES HAVING JURISDICTION. 3. MINIMUM WIRE SIZE SHALL BE #12 AWG. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE COPPER WITH THWN OR THHN INSULATION. 4. ALL MATERIAL SHALL BE NEW AND BEAR THE UNDERWRITES LABEL (U. L. ) WHERE APPLICABLE. 5. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. 5. THE ELECTRICAL, TELEPHONE, AND CABLE TELEVISION INSTALLATIONS SHALL MEET ALL REQUIREMENTS BY THE LOCAL UTILITY COMPANIES. 7. ALL DISCONNECT SWITCHES SHALL BE RATED FOR 100,000 A. I. C. UNLESS OTHERWISE NOTED. ALL FUSES SHALL BE RATED FOR 200,000 A. I. C. AND SHALL BE CURRENT LIMITING. 8. ALL ELECTRICAL SWITCHGEAR SHALL BE BY SQUARE D. ITE, GE, OR CHALLENGER. SUBSTITUTES MUST BE APPROVED BY THE ENGINEER. 9. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS. PLASTIC BOXES MAY BE USED IN LIEU OF THE STEEL BOX WHERE PERMITTED BY LOCAL CODES. IN DAMP OR WET LOCATIONS BOXES SHALL BE MADE FROM CAST ALLOY WITH THREADED HUBS. SPECIAL ENCLOSURES ARE REQUIRED FOR OTHER CLASSIFIED AREAS. 10. SEPARATE WIRE AND CONDUIT SYSTEM MAY BE SUBSTITUTED WITH FACTORY FABRICATED ASSEMBLY OF INSULATED CONDUCTORS IN A FLEXIBLE METALLIC ENCLOSURE WHERE PERMITTED BY LOCAL CODES. 11. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC WITH OVERLOAD RELAYS IN EACH HOT LEG. IT SHALL BE THE ELECTRICAL CONTRACTOR TO PROVIDE ALL STARTERS WHERE REQUIRED. 12. FURNISH AND INSTALL DISCONNECT SWITCHES, OVER CURRENT PROTECTION, AND WIRING FOR THE AIR CONDITIONING SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS ARE TO BE SUPPLIED BY THE AIR CONDITIONING CONTRACTOR AND CONNECTED BY THE ELECTRICAL CONTRACTOR. 13. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTED BY THE ENGINEER OR ARCHITECT. 14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION.. 15. THE ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) ONE YEAR FROM THE DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 16. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OR PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 400A 240/1PH - (3) - 350 MCM CU. IN 3-1/2"C OMETER SOCKET AND METER 400 A DISC W/400A "DE' FUSES 1-#3/0-CU GND TO 5/8" X 8' CU CLAD NEMA 3R ROD, C.W.P. ( 3) -500 MCM CU, IN 3-1/2"C ( 3) -500 MCM CU. 1#3 GND-3-1/2"C TO PANEL "A" IN MECH ROOM POWER PISEP DIAGRAM PN4 PNL A • B. 400A 100A 2P 2P NEMA 1 NEMA 1 13PA O O CU. 1#13 GND-1-1/4"C (3)-500 MCM CU, 1#3 GND-3-1/2"C NOTE : ALL WIRING SHALL BE COPPER TYPE "THW" UNLESS NOTED OTHERWISE . NOTE: SYSTEM TO PROVIDE A U.L. SERIES RATING OF 22,000 A.I.C. PANEL "A" VOLTAGE: 240 12OV, IPH, 3W BUS RATING: 400 AMP MAINS: NONE MOUNTING: SEE PLANS A. I. C. RATING 22,000 LOAD SERVED LOADS (WATTS) CKT IC BRKR N K 0 . PHASE C NJ K 0 T CKT BRKR LOADS (WATTS) LOAD SERVED LTS RECPT MOTOR HEAT AMP/PIT A B AMP LTS RECPT MOTOR HEAT CU-1 [3750] 3750 60/2 -- 1 3 * - - * 2 4 60/2 650 850 4800 4800 AH-1 CU-2 --- [3750] 3750 60/2 -- 5 7 * - - + 6 8 60/2 - 650 650 4800 4800 AH-2 SERVICE RECPT PHONES 360 360 20/1 20/1 9 11 * - - * 10 12 20/2 -- 937 937 EXT LTS - EWH 2250 2250 25/2 --1 13 15 * - - * 14 16 20/2 -- 1385 1365 LOW BAY LTS -- PANEL "B" 4080 2800 8080 8088 0 0 0 0 100/2 - 17 19 • - - * 18 20 20/2 -- 1365 1365 LOW BAY LTS -- SIGN - SITE EWC 1200 800 20/1 20/1 21 23 * - - * 22 24 20/2 -- 1365 1365 LOW BAY LTS -- DOCK RECPT DOCK RECPT 1080 1080 1 20/1 20/1 25 27 + - - + 26 28 20/1 20/1 250 350 SOFFIT LTS WAREHOUSE EMER LTS WAREHOUSE RECPT WAREHOUSE RECPT 1080 1080 20/1 20/1 29 31 + - - * 30 32 20/1 20/1 IRRIGATION PUMP --- 1200 1200 20/2 -- 33 35 * - - * 34 36 20/1 20/1 FRCP 360 20/1 20 1 37 39 + - - * 38 40 20/1 20/1 41 * - 42 LTS 8080 RECPT 22368 MOTORS 2400 HEAT 4500 SUB TOTALS LTS 10664 RECPT 0 MOTOR 2600 HEAT 19200 PHASE LOADING LTS RECPT MOTORS 18.71 22.4 5.0 1.251 16.2 1.00 NOTES: 23.4 1 16.2 5.0 "H" INDICATES HACR RATED BREAKER. [ ] INDICATES NON -CONCURRENT A/C LOAD. SIZES BASED ON LARGEST LOAD. HEAT LTS I RECPT MOTORS HEAT 23.7 CONNECTED KW TOTALS PHASE A 105621 10960 2500 11850 1.00 DEMAND PHASE B 6182 11408 2500 11850 23. 7 ADJUSTED KW TOTALS 69.8 TOTAL CONNECTED KW PHASE TOTALS A 35872 B 33940 68.3 TOTAL ADJUSTED KW 240 SINGLE PHASE VOLTAGE 07/10/04 :DATE JOB NAME: 03: 46 PM :TIME COLEMAN 1 285 TOTAL PANEL AMPERAGE: PANEL " B" VOLTAGE: 240 12OV, SPH, 3W BUS RATING: 100 AMP MAINS: NONE MOUNTING: SEE PLANS A. I. C. RATING 22,000 LOAD SERVED LOADS (WATTS) CKT BRKR C N K 0 T . PHASE C N K 0 T . CKT BRKR LOADS (WATTS) LOAD SERVED LTS RECPT MOTOR HEAT AMP A B AMP LTS RECPT MOTORI HEAT RECPT RECPT 1080 loos 20/1 20/1 1 3 * - - * 2 4 20/1 20/1 1600 1800 LTS ILTS RECPT RECPT 1080 1080 20/1 20/1 5 7 * - - * 6 S. 20/1 20/1 1800 1200 LTS LTS RECPT REFRIG 1080 600 20/1 20/1, 9 11 + - - * 10 12 20/1 20/1 880 1 1080 LTS RECPT COFFEE RECPT Boo 1080 20/1 20/1 13 15 * - - * 14 16 20/1 20/1 1080 1080 RECPT RECPT EWC Boo 20/1 20/1 17 19 + - - • IS 20 20/1 20/1 1080 1080 MOD FURN MOD FURN 20/1 20/1 21 23 * -1 - 1*1 22 241 20/1 20/1 1080 1080 MOD FURN MOD FURN LTS ol RECPT 8608 MOTORS 0 HEAT 0 SUB TOTALS LTS 1 6880 RECPT 7560 MOTOR 0 HEAT 0 PHASE LOADING LTS RECPT MOTORS 6.91 15.2 0.0 1. 251 13.1 1.00 NOTES: 8.61 13.1 0.0 "H" INDICATES HACR RATED BREAKER. [ ] INDICATES NON -CONCURRENT A/C LOAD. SIZES BASED ON LARGEST LOAD. HEAT LTS I RECPT MOTORS HEAT 0.0 CONNECTED KW TOTALS PHASE A 4080 8080 0 0 1.00 DEMAND PHASE B 2800 8088 0 0 0.0 ADJUSTED KW TOTALS 23.0 TOTAL CONNECTED KW PHASE TOTALS A 12160 B 10888 21.7 TOTAL ADJUSTED KW 240 SINGLE PHASE VOLTAGE 07/10/04 :DATE JOB NAME: 03: 46 PM :TIME COLEMAN 90 TOTAL PANEL AMPERAGE: 5-18-04 BLDG DEPT COMMENTS 7-12-04 OWNER CHANGES O O O C� 60 ca Y � 0 0 I 0 C�rJ f° • O 4 �+ .b m U �- A � U � 00 DO n \ O Cce3 O CD � 41 O wIy a �W � \l� V O O THESE PLANS ANN0 AV -PROPOSED WORK ARE SUBJECT T, ANY C�yR,REC TIOt3E � EQUIRED BY � r �„"lw �°°_' 'I"" �:CTOHS TMT 1 MAYBE NEC S;,Z IN ORCER'o COMPLY Wi o AU.l► °�i,I10 COIEiEEr �i °i ail 'EVI 10 O O 4j U 0 cs �I -- �, 0 O v U Z z a m 0 'Lno d U rr+s o m UDD OM: (z h+ 4 w n I IS N d V nz Ir"11 M 0�N r� OvE O ��'" x� Lr z ~ `/ z 0 a J a CD W 'a_ � M � C-3 Z znF- Snz 610U V Svc VJ -7 Uo0 QL iD IL W PROJECT NO. 10504 r DATE: MARCH S, 2004 V SHEET: E-3 I 2 a 37 OUSE USE: IND IL i ' EX. S" PVC r WATER MAIN —WM— —WM DRAINAGE EASEMENT T_s LOT 22 VACANT FUTURE LAND USE: IND ZONING: IL 13'- 4" 8"CONCRETE BLOCK WALLS W/STUCCO --d 2 LOT 38 VACANT FUTURE LAND USE: IND ZONING: IL - —WM —WM— WM -- ._WM_ _ GRAPHIC SCALE / ` LOT 40 - - - -- ` \ / VACANT COMMERCIAL CIRCLE \ FUTURE LAND USE: IND lilt- ZONING: IL c \ — _— M \ G9 24" STOP BAR14) �ILJ l�t/z\ f( ( IN FEET ) �- 1 inch = 20 ft. LOT 39 VACANT ^- FU RE LAND USE: IND ING: IL —WM --------- __..L--. SIGN PARKING BY ➢IIA13LE➢ PERMR ONLY Y250 FINE FTP 26 h 12' � 5 f250 FIN FTP 25 NQIE:S 1„ TOP PORTION OF FTP 25 & 26 SHALL HAVE REFLECTIVE BLUE BACKGROUND WITH WHITE REFLECTIVE SYMBOL AND BORDER, 2S BOTTOM PORTION SHALL HAVE A REFLECTIVE WHITE BACKGROUND WITH BLACK OPAQUE LEGEND AND BORDER 31. FTP 25 & 26 MAY BE FABRICATED ON ONE PANEL OR TWO. 4;, FTP 25 IS FOR USE IN AREAS WHERE SPACE IS LIMITED. HANDICAP SPACE DETAIL 3S, -__ `` . \� \ L CI CA T► C7 N MAP LEGAL DESCRIPTION LOT 23, BLOCK B, KINGS HIGHWAY INDUSTRIAL PARK, UNIT 2, ACICORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOK 32, ?yy3¢8• \�` ,� \ `�\\\ \ \ PAGE 5, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. n^ COINTAINING 1.29 ACRES CERTIFY THAT ) N1I r )Ts ----------- \ THIS !S Ta \ �`S �� �\ \ PARCEL ID NUMBER: 133580200450001 , '� - - - - - - - - OF THE THE ILUCIIINI1ts C TECHNICAL r \ o TYPE 'D' � � � OF THE ST. LLDCiE COUNTY LAND iDc:'v'1..LC14 Pw �.:� O \ \ \ \ SECTION 35, TOWNSHIP 34 SOUTH, RANGE 39 A1. CURB (TYP.) \ �j� q \ CODE, THIS APPROVAL DOES NOT GO \ \ISOLATION �p \ \ \\\ \ \\ / OWINERCT NAME: WIOLLIAMN BLOBUEROSSE SR. �p�gT1{�ICTSIOION AU F TH ATION UNTIL PROPOSED M NHOLE O \ raDG¢� PpOVIS10NS OF THE PROJECT DEVE.IOP- PAVEMENT O• \� \ WILLIAM B. BUEROSSE JR. PROPOSED CONCRETE � `7U Oae �` \ �\ � 3450 NE 6th TER. �+IENT A�Spp(,)VAL HAVE BEEN COMPLIED WITH P" o ` POMPANO BEACH, FL. 33069 EI:,lRTHEfl IDENTIFI D I COhAMUNiTY DEeIELOP' - a DUMPSTER PAD W/ 6' G}"\p- T \ \ \ iDL "b0±cr ` HIGH MASONRY WALL %, \ os \ MEN T O & 100% OPAQUE GATES R CIS \ ENGINEER: JOSEPH T. FRISCIA,P.E. \ \ \ \` \` - FRISCIA ENGINEERING ADMINI$TRATOFi (SEE DETAIL) Op• � � \ ` \ \ 681 SW WHITMORE DRIVE 14 Q�E(,(jP(1A NT PORT ST. LUCIE, FL 34984 SIDE BUILDING �� ® �` \ �\ 5� (772) 340-4990vA O- PROPOSED \ SETBACK IRRIGATION \ \\ A+k� rr WELL \ \ LANDSCAPE ARCHITECT: WILLIAM A. FLINT, III Zxra....— ` \ LANDSCAPE ARCHITECT PROPOSED GF \ \` 2310 SE COUNTRY CLUB LANE 8" BLOCK WALL ��` �� ` \ STUART, FL 34996 LOT41 (772) 220-0424 40' 15.6T ;1 ';'< WAREHOUSE SURVEYOR: BISHMAN SURVEYING AND MAPPING, INC. E'II¢ \ UTURE LAND USE: IND u g * L 808 ELM FOP. L DRIVE ,. I gg \ 1111 I II,I \ 1 ZONING: IL CLERMONT, FL 34711 PROPOSED 12"x 18"CONCRET TRUCK WELL \ Q I 1 1 FOOTINGW/3#6B RS ELEV. -48" \ 11 I III 1 CONT. %illl I LOCATION: IL CIRCLE, KINGS HIGHWAY INDUSTRIAL PARK ZONING: I I ` 1 II ` I LAND USE: IND 8"CONCRETE BLO KW "ALLW/ W 20 +� \� IIII I II I { UTIILITIES: STUCCO (BOTH SID S) W/ f p, 135.00' h + 5 11 I LLED CELLS & 1 #5 BAR AT ` 1� 1ppI WATER FORT PIERCE UTTLITIES AUTHORITY LOCATIONS SHOW GD I o I P89 ( I ;I i I � WASTEWATER FORT PIERCE UTILITIES AJTHORITY z II I i I SITE DATA: 4"DIA, x42"HIGH STEEL 5' 61 18' 26' I I SQ. FT. ACRES `� I II BOLLARD Wl18" 18' II I TOTAL AREA 56,095 1.288 100.00 EMBEDDED INTO CONCRETE i IMIPERVIOUS AREA: 15, 100%OPAQUE DRAINAGE GATES EASEMENT , -_A 8"x8"BOND BEAM — �WI 2 #5 BARS CONT. STEEL STUCCO BOLLARD 1 1 � �LJL---------------J -u DUMPSTER DETAIL 1 5 _ _... _. a C, a O o II PROPOSED BUILDING 14,985 0.344 26.72 CL LO — — PROPOSED PAVEMENT 15,215 0.349 27.12 ~ 3II iI I\ TOTAL IMPERVIOUS AREA 30, 2U0 0.693 5-3 PERVIOUS AREA (OPEN SPACE): 25,895 0.594 46.16 EASEMENT PROPOSED a o o I `�` PARKING CALCULATIONS: ONE-STORY METAL a c v n��� '1 SPACE PER 1,000 S.F. I I WAREHOUSE BUILDING C41 N ^ i PARKING REQUIRED = $ H.C. SIGN a ?S• A i`- WAREHOUSE AREA = 14,985 S.F. FLOOR AREA = 15,120 S.F. (SE DETAIL - -"----"------""' F.F.E. = 20.00 ) N T PARKING REQUIRED 14,985/1,ODO 15 SPACES (1 HANDICAPPED) HEIGHT - 25' o a I PARKING PROVIDED = 15 SPACES (1 HANDICAPPED) 0 o °sioP OOcce� '�' S' FIRE DEPT. I BUILDING SETBACKS (IL) +� CONNEC ION N i FRONT: 25 FT. 3 SLIDE: 10 FT. ° FR NTBUILI) SETBA(•.$ I I SIDE CORNER: 20 FT. <„ I I REAR: 20 FT. I � al N m c� G I � N o W WATER SERVICE � N I 20' FIRE LINE - - ea -----9Q--1 ®v TRACT 'A` (STORMWATER MANANGEMEN ), CONTROL ELEV. = 14.0 1D' AINTENAN CRESTELEV = 15.2 &UTILITY EASEMENT CAD DWG 03657SP LEGEND RUNOFF FLOW DIRECTION ,= TRAFFIC FLOW DIRECTION C� BLOCK NUMBER MITERED END SECTION 10 NUMBER 'OF PARKING SPACES HANDICAP STALL ' m N89'30'55"W 245.00' LOT 24 VACANT FUTURE LAND USE: IND ZONING: IL 2' PAINTED STRIPE (T'P.) CARSTOP a (FYP.) 18' NOTE, MINIMUM FINISHED FLOOR ELEVATION TYPICAL 18' PARKING STALL FOR PROJECT IS 18, 5' N. G, V. D. 1" = 5' (S. F. W. M, D. PERMIT NO, 56-00599-5) try - u R I i I Lu I I I I I I I I I � I R I I I I I i 1 „ I I I I I I I I II I 1DS. i I I UTILITY EASEMENT I I I I I I I I I LOT 42 NAHEHOUSE E LAND- U$E: IND BUILDING HEIGHT: 25' ZONING: ILA\ DRAINAGE NOTES: '---------- / STIORMWATER RUNOFF WILL BE ROUTED TO EXISTING LAKE IN THE MASTER DRAINAGE SYSTEM. WATER QUALITY AND QUANTITY TREATMENT ARE PROVIDED BY THE MASTER SYSTEM (SFWMD PERMIT #56-00599-S). DEVELOPMENT SCHEDULE: BEGIN CONSTRUCTION: MARCH 2O04 ENID CONSTRUCTION: 120 DAYS W I K I I I I WV I LK A I I i I I I � I IL•J I I , II; LOT 43 A USE FUTUR L LAND USE: IND PHONING: IL I I ✓I�� 6 0 JOSEPH T. FRISCIA, P. E. FLA. REG N0, 31443 Date Revisions 1-27-04 ADD DRAINAGE 2-16-04 PER DRC 3-17-04 PER SLC 00 W m r M O Z � M ry W4 U J —Nn v M c O W 9- Z H- w ° v � o � W O� d 0 u N Q uj or o a v o a iU N La LL. }y N v La N w — 00 D aL U J w a. d3 rr Ii In DRAWN MAF CHECKED J,T,F, DATE 11-24-03 SCALE 1' = 20' JOB NO. 03657 SHEET 1 OF SHEETS WM N DRAINAGE EASEMENT F�<N W ��-OT 37 I LOT 38 WAREHOUSE VACANT FUTURE LLLLAAAANO USE: IND ( FUTURE LAND USE: IND ZONING: IL I ZONING: IL I I - I I II I \ - I / EX. S" PVC WATER MAIN / WM— WM \WM—{ I'Y'7- WM —WM— WM IIII -------------------------------------------a---�OMMERCIAL CIRCLE I I I I / LOT ao \/ VACANT / FUTURE LAND USE: IND — se GS — I GA I ID '—`Zc \ ZONING: IL ------------------ Gs I I GS 24" STOP BAR \ LOT 22 VACANT FUTURE LAND USE: IND ZONING: IL u I I = I I O IN N I L-- ---- W CONCRETE BLOCK WALLS W/STUCCO _____________________ - ---------- _____ `__-------------------- ' BAND \,8" x 8" BOND BEAM W/ 2 #5 BARS CONT. STEEL STUCCO v BOLLARD L I - - - - - - - - - - - - - - - J DUMPSTER DETAIL 1"=5' lu_41 GRAPHIC SCALE 0 10 20 40 ( IN FEET ) I inch = 20 ft. LOT 39 VACANT FJUlURE LAND USE: IND NING: IL wv M 7Ss TYPED' oo, \ `\ CURB (TYP.) EC- �� o PROPOSED `-\ ISOLATION i7 \`90, \\s\ PAVEMENT M NHOLE 00, \\\\ \\\ PROPOSED CONCRETE DUMPSTER PAD WI6' HIGH MASONRY WALL ` OPAQUE GATES ( (SEEEE DETAIL) 15' \ SIDE BUILDING �70. PROPOSED SETBACK IRRIGATION WELL PROPOSED \ \\ \ 8" BLOCK WALL LOT 41 WAREHOUSE 29' 35.87' L ,I _ `< FUTURE LAND USE: IND PROPOSED ` ZONING: IL 99 I \ 12"x18"CONCRET TRUCK WELL 92. \ \ I\ y I\ FOOTINGW/3#5 S ELEV.-48" CONT. III '10 III `up�7 \III I� IIII 1 8" CONCRETE SL K WALL W/ \++ 20 - +'Q STUCCO (BOTH SID S) W/ i 71' 135.00' (,j + 1 I I I FILLED CELLS & 1 #5 BAR AT ) II I I I LOCATIONS SHOW S Tal 1 4"DIA. x 42"HIGH STEEL 5' 68 26 II II BOLLARD W/ 18" II I I I EMBEDDED INTO CONCRETE 15' 15' 100%OPAQUE — GATES DRAINAGE DRAINAGE EASEMENT I EASEMENT em, I TRACT 'A' WATER MANANGEMEN CONTROL ELEV. = 14.0 10 NTENAN CREST ELEV. = 15.2 - & UTILITY EASEMENT I I CAD DWG 03657SP PROPOSED ONE-STORY METAL WAREHOUSE BUILDING FLOOR AREA = 15,120 S.F. F.F.E. = 20.00 HEIGHT = 25' LEGEND -�-_ RUNOFF FLOW DIRECTION TRAFFIC FLOW DIRECTION <=> BLOCK NUMBER MITERED END SECTION 10 NUMBER OF PARKING SPACES HANDICAP STALL 18' I II II ; _ I C p -- F I ^ I I H.C. SIGN N a 6 (SE DETAIL) p L sLo� �OO�O�OOO v' S' FIRE DEPT. 17 N p +b CONNEC ION c Imo— FIR NT BUILDINd SETBA� N p O WATER SERVICE M FIRE LINE ICU �0F W NWW IN N89030'55"W 245.00' 2' LOT 24 VACANT FUTURE LAND USE: IND ZONING: IL CAR STOP (TYPJ PAINTED STRIPE (TYP.) b 1B' NDTEI MINIMUM FINISHED FLOOR ELEVATION TYPICAL 18' PARKING STALL FOR PROJECT IS 18, 5' N. G. V. A 1"-5' (S. F, W, M, D, PERMIT NO, 56-00599-5) I LOT 42 1&R_EHOUSE 2E LANd'U,-,E: IND ZONING: IL ``. I LOT 43 AREHOUSE UTU E LAND USE: IND ZONING: IL (-)----S IGN FTP 26 12' 5, urtir (MiN,) f8S0 FIN FTP 28 NOTES 1, TOP PORTION OF FTP 25 & 26 SHALL HAVE REFLECTIVE BLUE BACKGROUND WITH WHITE REFLECTIVE SYMBOL AND BORDER. 2. BOTTOM PORTION SHALL HAVE A REFLECTIVE WHITE BACKGROUND WITH BLACK OPAQUELEGEND AND BORDER. 3. FTP 25 & 26 MAY BE FABRICATED ON ONE PANEL OR TWO. 4. FTP 25 IS FOR USE IN AREAS WHERE SPACE IS LIMITED HANDICAP SPACE DETAIL LOCATI G7N MAP LEGAL DESCRIPTION LOT 23, BLOCK B, KINGS HIGHWAY INDUSTRIAL PARK, UNIT 2, ACCORDING TO THE PLAT THEREOF, RECORDED IN PLAT BOOK 32, PAGE 5, OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA. CONTAINING 1.29 ACRES PARCEL ID NUMBER: 133580200450001 SECTION 35, TOWNSHIP 34 SOUTH, RANGE 39 PROJECT NAME: COLEMAN FLOORING OWNER: WILLIAM B. BUEROSSE SR. WILLIAM B. BUEROSSE JR. 3450 NE 6th TER. POMPANO BEACH, FL. 33064 ENGINEER: JOSEPH T. FRISCIA, P.E. FRISCIA ENGINEERING 681 SW WHITMORE DRIVE PORT ST. LUCIE, FL 34984 (772) 340-4990 LANDSCAPE ARCHITECT: WILLIAM A. FLINT, III LANDSCAPE ARCHITECT - 2310 BE COUNTRY CLUB LANE STUART, FL 34996 (772) 220-0424 SURVEYOR: BISHMAN SURVEYING AND MAPPING, INC. 808 ELM FOREST DRIVE CLERMONT, FL 34711 (407) 702-8127 LOCATION: COMMERCIAL CIRCLE, KINGS HIGHWAY INDUSTRIAL PARK ZONING: IL LAND USE: IND UTILITIES: WATER FORT PIERCE UTILITIES AUTHORITY WASTEWATER FORT PIERCE UTILITIES AUTHORITY SITE DATA: SQ. FT. ACRES o TOTAL AREA 56,095 1.288 100.00 IMPERVIOUS AREA: PROPOSED BUILDING 14,985 0.344 26.72 PROPOSED PAVEMENT 15,215 0.349 27.12 TOTAL IMPERVIOUS AREA 30,200 6. 993 53.84 PERVIOUS AREA (OPEN SPACE): 25,895 0.594 46.16 PARKING CALCULATIONS: PARKING REQUIRED = 1 SPACE PER 1,000 S.F. WAREHOUSE AREA = 14,985 S.F. PARKING REQUIRED = 14,985/1,000 = 15 SPACES (1 HANDICAPPED) PARKING PROVIDED = 15 SPACES (1 HANDICAPPED) BUILDING SETBACKS (IL): FRONT: 25 FT. SIDE: 10 FT. SIDE CORNER: 20 FT. REAR: 20 FT. BUILDING HEIGHT: 25' DRAINAGE NOTES: STORMWATER RUNOFF WILL BE ROUTED TO EXISTING LAKE IN THE MASTER DRAINAGE SYSTEM. WATER QUALITY AND QUANTITY TREATMENT ARE PROVIDED BY THE MASTER SYSTEM (SFWMD PERMIT #56-00599-S). DEVELOPMENT SCHEDULE: BEGIN CONSTRUCTION: MARCH 2O04 END CONSTRUCTION: 120 DAYS JOSEPH T. FRISCIA, P. E. a FI A. w7n. Nn. 'i1 AAq rD7.Revlsions 1-27-04 ADD DRAINAGE 2.16-04 PER DRC 3-17-04 PER SLC 04.14-04 REVISED TRUCK WELL PER CLIENT a rn W O\ I M z FE w N LiJ = C J D W s z_N¢� a U' o z C W 0 o u w rn 4/Y O -t 'o a M z LL_ vi r,. w z z � w a U J w o_ m O_ a m DRAWN MAF CHECKED J.T.F, DATE 11-24-03 SCALE V = 20' JOB NO. 03657 SHEET 1 OF SHEETS GRAPHIC SCALE 20 0 10 20 40 80 I i i I I IN FEET) / 1 inch = 20 ft. I I / 1 / 8"PVC `� IOII OI WA r WATER MAIN x Jy_ I - WM- f- WM WM- -� WM --WM- -WM- -WM I I I I �- WM 1` I III ---------------- --- -- -- _ `\ (NORTH RIM =17.09) \ •� \\\\ / .COMMERCIAL CIRCLE W V=9.83 -- SITE BENCH MARK - N- - - wM�� \ / as -- as GS GG _-- _r^� E INV=9.84 \ \ \ M \ FLUSH HEADER CURB IN (TYP.) (SEE DETAIL) i�i i i (80' R/W) CONSTRUCT STABILIZED as e Inl ery CONSTRUCTIC44 ENTRANCE GS ._____________________________________________________i^________I�III ^� 6' 09"' ro III as (PER FDOt INDEX #106) - ----------- INV. 15.1p1 75 L.F. 16" RCP 0,2MES MHX 0/V1731MES NV"WINIM 1437 \ \^�' NW INV=70.29 \ in DRAINAGE - - - - _ _ `i`,,SE INV-10.31 EASEMENT INV. EL. S"a1'nt" 8aE 90.00' 16- _ \ `� `\\\ 't✓ \ Z t4.41 IT- "IB ��------19.0----------- CROWN__ � �� �� \ 4d \ \ cs `• \ 19.39 M � T.E. 18.96 `� - \ \\ \ Oo, +� IT. 14.40 W. INV. 14.50 S. INV. 14.50 19 9 - I I 65 L.F. 15S " RCP @ 0.15% 45 L.F., I.C. @ 0.50% 45 L.F., I.C. @ 0.50% 19.27 19.39 \) CONST\ffjOLATION \ \\ \\ \ 19.19 zi ( MANHOLE\ +,0' \ I TOP EL. C I I I I I C 70 L.F. 6"SCH. 80 c s I (DETERMINE LATERAL INV. PVC @ 1.43% 19 39 19.51 \EL. IN FIELD) \ lit" 19.49 F19.49 ® \ \ \ PROPOSED IRRIGATION I WELL 0�, I i i }^ �1g 0\\ SEE ARCHITECTS PLAN \ �\ ^ SITE NENCH MARK `\ ^�e° I�O�^?RUCK WELL DETAIL \ „� \ ^� (RNIAO9�RT7H�ROIM ®17.80) 7 \ im \ + \ \\ NWV00.@B \ � 7 \ 16.00 o 19.94 1994. w TRENCH DRAIN 135.00' I I N W INV. 15.50 1 zl 19.28 1 I I lid, I 19.78 I 19.28 I I IiI I yyP'-'111I ',i Ak 1 A� I ^h�b } + PROPOSED �1 i� s� I s' ONE-STORY METAL DRAINAOE DRAINA MES EIASEM NT EAJEMO WAREHOUSE BUILDING `. TE#EL 18.70 I 5z I I INV. 18,0 1 FLOOR AREA = 15,120 S.F. INV. 16.20 R �i MES F.F.E. = = 25' 49 L.F. 15" RCfb @ 0,41 / I INV. 15.9 $ HEIGHT = 25' 19.78 l 3 1 +^ts,.71 4DEPT, 1 (612:1 000000000 i o}^ ^� o I I I oa + 19.78 19.28 FIRE 19.28 7 M v CONNECTION I = F3 (BY SPECIALTY// i I CO z - CONTRACT05t) I N w ^. 19.78 / I d v UZJH 19.28 18.97 \ j 19.2 a. oaoFpl O �o �f x.I 3' } + \ L. .3 + /^ ^' N 4 GPx x o w j i OpQ�Q^/%xx r TRACT 'A' (STORMWATER MANANGE CONTROL ELEV. = 14.0 CREST ELEV, = 15.2 CAD DWG 03657SP I I 10' NTENAN & UTILITY EASEMENT I LEGEND EXISTING GRADE ELEVATION +ryPg T/CURB 21.50 1 PROPOSED ELEVATION 21.00 (H.P, = HIGH POINT) B/CURB AS -BUILT ELEVATION O PIPE INTERFERENCE POINTS s-L RUNOFF FLOW DIRECTION PROPOSED CONTOUR - 35.6 - ELEVATION FDOT MITERED END SECTION N89030'55"W 246.00' TYPE III SILT FENCE BARRIER PER FDOT INDEX #102.3 (TYP.) ry� } ^0 TOP OF PAV. EL. 17.3 M (JtHVIUL / OR) CONST. 1" RPZ, V WATER METER (BY FPUA) PROP. 4" WATER MAIN DIRECTIONAL BORE �6" PVC SANITARY SEWER INV. EL. 11.43 INTERFERENCE POINT #1 N.T.S. I 4"x8" WET TAP I GENERAL NOTES: l.. ALL MATERIALS AND WORKMANSHIP SHALL BE IN ACCORDANCE WITH THE LOCAL BUILDING CODES AND THE SECTIONS OF THE FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE CONSTRUCTION, CURRENT EDITION OTHERWISE AUTHORIZED BY THE ENGINEER IN WRITING. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY OFF -SITE DAMAGE, RESULTING FROM HIS OPERATIONS, TO EXISTING PAVEMENT, SWALES, ETC... 2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR INSPECTING THE SITE PRIOR TO BIDDING WORK AND SHALL TAKE INTO CONSIDERATION ANY OMISSIONS, UNDERGROUND UTILITIES, OR OTHER ITEMS AFFECTING THE INSTALLATION OF PAVING AND DRAINAGE. SHOULD UNCHARTED OR INCORRECTLY CHARTED UTILITIES OR OTHER ITEMS BE ENCOUNTERED DURING CONSTRUCTION, CONSULT PROJECT ENGINEER IMMEDIATELY FOR DIRECTIONS. REPAIR DAMAGED UTILITIES OR OTHER ITEMS TO SATISFACTION OF UTILITY OWNER AND PROJECT ENGINEER. 3. ALL BERMS AND GRASSED AREAS WILL BE SEEDED AND MULCHED IN ACCORDANCE WITH THE APPROPRIATE SECTIONS OF THE ABOVE REFERENCED SPECIFICATIONS UNLESS OTHERWISE AUTHORIZED BY THE ENGINEER. 4. ALL SLOPES TO BE MAXIMUM 1:4 UNLESS NOTED. ALL SLOPES SHALL, BE SODDED. 5. LOCATION OF DRAINAGE STRUCTURES SHALL GOVERN AND PIPE LENGTHS MAY HAVE TO BE ADJUSTED TO ACCOMPLISH CONSTRUCTION AS SHOWN ON THESE PLANS. 6. IF HARDPAN IS ENCOUNTERED WITHIN RETENTION AREA OR SWALES, IT SHALL BE REMOVED AND REPLACED WITH A GRANULAR MATERIAL. 7. IF MUCK IS ENCOUNTERED, IT SHALL BE COMPLETELY REMOVED AND BACK FILLED WITH A GRANULAR MATERIAL AND COMPACTED TO DENSITIES SUFFICIENT TO ACCOMMODATE THE INTENDED USE. 8. EROSION AND SEDIMENT CONTROL- CONTRACTOR IS RESPONSIBLE FOR PROVIDING EROSION AND SEDIMENT CONTROL USING THE LATEST F.D.O.T. STANDARDS. BALED HAY, STRAW, AND SILTATION BARRIERS WILL BE INSTALLED WHERE NEEDED TO PREVENT SILTATION OF ADJACENT PROPERTY, PUBLIC RIGHT-OF-WAY, WETLANDS AND WATERWAYS. THESE WILL REMAIN IN PLACE UNTIL GRASSING OR SODDING HAS BEEN COMPLETED OF UNTIL SILTATION AND EROSION ARE NO LONGER A THREAT TO ADJACENT PROPERTY AND WATERWAY. 9. RCP INDICATES REINFORCED CONCRETE PIPE. CMP INDICATES GALVANIZED CORRUGATED METAL PIPE. BCCMP INDICATES BITUMINOUS COATED CORRUGATED METAL PIPE. CAP CORRUGATED ALUMINUM PIPE. CPP INDICATES CORRUGATED POLYETHYLENE PIPE (N12) MANUFACTURED BY ADVANCED DRAINAGE SYSTEMS, INC. (ADS). 10. ALL INLETS SHALL BE TYPE "C" PER F.D.O.T. INDEX #232 W/ CAST IRON GRATES. 11. ENTRANCE TRAFFIC CONTROL - STOP SIGN, STOP BAR AND LANE DELINEATOR SHALL BE IN ACCORDANCE WITH M.U.T.C.D. SPECIFICATIONS AT ALL ENTRANCE LOCATIONS. 12. BOUNDARY AND TOPOGRAPHIC INFORMATION TAKEN FROM SURVEY BY HISHMAN SURVEYING AND MAPPING, INC., PROFESSIONAL LAND SURVEYORS, JOB NO. 03026.00 13. ALL AREAS DISTURBED BY CONSTRUCTION SHALL BE RESTORED TO PRE -CONSTRUCTION CONDITIONS OR BETTER. 14. MES INDICATES MITERED END SECTION PER F.D.O.T. INDEX #272. 15. ALL CURBS SHALL BE TYPE I'D" UNLESS NOTED OTHERWISE. CONSTRUCTION FIELD OBSERVATIONS I. DRAINAGE A. LAYING OF PIPE (BEFORE BACKFILL) B. ALL DRAINAGE STRUCTURES AND PIPE LAYING COMPLETE. C. CONSTRUCTION AND STABILIZATION OF RETENTION AREAS AND SWALES. D. SEEDING, MULCH AND SODDING IN AREAS WHERE EROSION IS EVIDENT. 11. UTILITIES (PERMITS) A. PIPE LAYING WITHIN RIGHTS -OF -WAY. B. JACK AND BORING IN RIGHTS -OF -WAY, III. CONCRETE A. CONSTRUCTION OF CURBING, SIDEWALK AND RETAINING WALLS BEFORE PLACEMENT OF CONCRETE. IV. PAVEMENT A. LINE AND GRADE (CERTIFICATION). B. SUBBASE (PRIOR TO ADDING BASE MATERIAL) C. BASE (PRIOR TO PRIMING .AND SAND SEAL) D. BASE (AFTER PRIMING, SAND SEAL AND BEFORE PLACING OF ASPHALT) E. ASPHALT OR CONCRETE (WHILE PAVING IS IN PROCESS). F. TURN OUT CONSTRUCTION ONTO CITY, COUNTY, OR STATE ROAD (ABOVE INSPECTIONS APPLY), G. TEST RESULTS ON SUBBASE, BASE AND ASPHALT. H. FINAL PROJECT OBSERVATION. PROJECT CERTIFICATION REQUIREMENTS I. TESTING A. FLORIDA BEARING VALUE TEST RESULTS B. COMPACTION TEST C. BASE MATERIAL TEST RESULTS D. ASPHALT TEST RESULTS 11. WATER AND SEWER A. DEPARTMENT OF ENVIRONMENTAL CERTIFICATION FOR BOTH WATER AND SEWER (OPERATION AND MAINTENANCE), IF APPLICABLE. B. HEALTH DEPARTMENT CERTIFICATION, IF APPLICABLE. C. BACTERIOLOGICAL FOR WATER MAINS. D. UTILITY ACCEPTANCE FOR OPERATION AND MAINTENANCE, IF APPLICABLE. III. CERTIFICATION AND RECORD DRAWINGS A. SEALED CERTIFICATION BY THE ENGINEER OF RECORD FOR COMPLIANCE WITH APPROVED PLANS AND SPECIFICATIONS ALONG WITH RECORD DRAWINGS FOR THE PROJECT. LL� Cana Pav9. Joini Preformed Mt Joint Filler TYPE D F . Note: For use adjacent to concrete or flexible pavement, concrete showh 4" min., rf mmr. min. Expanslan Joint, preformed joint filler and joint seal are regu/red between anr& and concrete pavement only, see diagram right. CONCRETE CURB T Yox. Depth Of Saws°t GENERAL NOTES 1. For curb,gufterond curb and gutter provide"- /x° contraction Joints at IO' centers lmox.l. Contraction joints adjacent to concrete pavement on tangents and flat curves are to mated the pavement Joints, with intermediate Joints not to exceed l0' centers. Curb,gutter and curb & gutter expansion joints s,,11 be Ixafed in axordance with Section 520 of the standard specifications. 2. Ends of Curbs Types 8 and D stroll f onsitfon tram full to zero heights in 3 feet. in. H' 4fi. PlM Wfbnal No. 4 BWs, l&' laq \Ow d Attlbed r I'IMo Par pwonN TYPE D T CONCRETE BUMPER WARD CONTRACTION ((J �B & Gy 1 Jr R DETAIL JaNT /N CURB F.D.O.T. INDEX NUMBER 300, 1994 SFWMD PERMIT NO. GP 56-00599-S MINIMUM ELEVATIONS (FT. - NGVD) (CONTROL EL. 14.0) MINIMUM FLOOR EL. 18.5 MINIMUM ROAD CROWN EL. 17.0 MINIMUM PERIMETER GRADE EL. 17.2 NOTE: ALL DRAINAGE PIPE JOINTS, INCLUDING ROUND CONCRETE PIPES, SHALL HAVE A FILTER FABRIC JACKET IN ACCORDANCE WITH FDOT ROADWAY AND TRAFFIC DRAINAGE STANDARDS. ALL RCP PIPE USED FOR EXFILTRATION ARE TO HAVE SLOTS, IN ACCORDANCE TO FDOT INDEX #285.2 OPTION 'B'. a JOSEPH T, FRISCIA, P, EI FLA. REG. NO: 31443 Date Revisions 04-14 04 REVI ED TRUCK WELL - PER LI T 00 v M p ZJ w C M W U J r � c w O L a z a W � � N .E QUJ `H UJ o E �(/Z to O LL ; v w z 00O a U J - w a of a DO DRAWN MAF CHECKED DATE 1-27-04 SCALE 1' = 20' JOB NO. 03657 SHEET 2 OF SHEETS z Z H— W J Li 8" to' 3" Or 5� _' i, Deepen Around Outside Edge Of Pipe For 5j ff 2 of3 NOTE: PAVEMENT SHALL HAVE MARSHALL STABILITY OF 1,000 LBS. ,PRIME COAT SEALANT TO BE APPLIED ON TOP OF LIMEROCK �2" FOOT TYPE S-1 ASPHALTIC CONCRETE 8" LIMEROCK OR COQUINA BASE COURSE 12" STABILIZED SUBGRADE W/ 751b. F.B.V. & L.B.R. =40 CAD DWG 03657SP EL. 16.00 TRENCH DRAIN SEE ARCHITECTS PLAN FOR TRUCK WELL DETAIL vl Or Round Corners Concrete Stab, 3" Or 5�" Thick. O� Reinforced With WWF 6x6-WI.4xW1.4 'O TOP VIEW -SINGLE PIPE SECTION 4a Miter: To @ Pa For Pipes 18" And Slwller. 2d For Pl'pes 94' And Larger. 2d Mlten To € Pipe For Pipes 0 And Shloller, hi For Pipes 24" And Larger. R/W 1" POLYETHYLENE TUBING SERVICE WATER MAIN CORPORATION STAINLESS STEEL 1" LOCKING METER DOUBLE STRAP I FLANGE CURB STOP SERVICE SADDLE I 90' ELL --,, FINISHED GRADE WATER MAIN z z 2 2 10 ° M N I FORD MODEL F1102 CORPORA nON OOR APPROVED EQUOAL 1" POLYETHYLENE TUBING SERVICE ConcreteL5Thlck,, h Sad Reinforced wnh wwF sxs-wl.4xw1.4 _� STAINLESS STEEL DOUBLE STRAP SERVICE SADDLE TOP VIEW -MULTIPLE PIPE ]� C WITH I.P. THREAD % NOTE: See sheet 6 for details and notes. CROSS O I✓ S DRAIN MITERED END SECTION R/W SINGLE AND MULTIPLE ROUND CONCRETE PIPE 1. BLUE 12 GAUGE THHN WIRE SHALL BE ATTACHED TO THE SERVICE LINE. F.D.O.T. INDEX NUMBER 272, 1994 1 of 6 2. WHERE SERVICES UNDER PAVEMENT ARE REQUIRED, THE POLYETHYLENE TUBING SHALL IN— STALLED WITHIN 4" DIA. CLASS 200 PVC CASING PIPE. SAW CUT JOINTS ® 15' O.C. EXPANSION JOINTS 0 40' O.C. OR 6" PORT. CEMENT CONC. PAVT. (3000 PSI) 8" STABILIZED SUBGRADE W/ 751b. F.B.V. ` IAPACTED TO 98% SEE ARCHITECTURAL PLANS FOR REINFORCING MAX. DRY DENSITY MOD. PROCTOR TYPICAL PAVEMENT DETAILS N.T.S. PAVEMENT TO BE CONSTRUCTED IN ACCORDANCE WITH AASHTO T-180 SPECIFICATIONS. *MPACTED TO 96% MAX. DRY DENSITY MOD. PROCTOR 1/2" CHAMFER 5 3,000 PSI CONCRETE 10 PAVEMENT m BASE COMPACTED SUBGRADE SIDEWALK/PAVEMENT DETAIL N. T. S. 'L 124' �L 30' 20' 29' 3' T- EDP L. 19.28 EL. 19.39 I.C. EL. VARIES PROP. PAVEMENT 18.70-1 S.W EXIST. GRADE EL. 17.67 1 PAVEMENT =— SECT B \ `� SCALE: V = 10' H �q\ \ PROP. 15" RCP 1'= Tv INV. EL. 15.10-16,25 L TE Ir90' ELL L BACKFLOW PREVENTER BY—PASS I FINISHED GRADE VALVE 1" COPPER SERVICE PIPE I i—PLUG & 90' ELL I I LIMIT OF UTILITIES AUTHORITY INSTALLATION TYPICAL SINGLE WATER SERVICE CONNECTION WITH WATER METER/BACKFLOW PREVENTER ASSEMBLY (METER SIZE 1-1/2 if & 21)) so' 15' 16 5' 1 6' 31' 31' 3' S' 6' 2' V± 11' 2' 12' DRAINAGE EASEMENT DRAINAGE EASEMENT 1 21.0 28. EDP OF 4' 19' VARIES 2' 19.19-79.49 SID K EL. 19.28 EL. 19.2 20.0 PROP. PAVEMENT EL. 18.0 CD EL.19. PROP, PAVEMENT z 18.0 I.C. EL. VARIES 1896-1819 1 EL. 1710 EL. 17.0 _EXIS_T. PAVEMENT _—� li. 18.0 EL. 170 El. 17.0� / / / TYPE D CURB \\� -1 LU160 \ i i EXIST. SWALE EL.15.9t 15.0 `j SECT C SCALE', 1 " = 10' H EL.15. �EL.15.0 1"=3'V SECT A I EXIST. SWALE SCALE: 1" = 10' H EL.14.93 i"= 3' V W — 2 A I L 4'x4'x6" CONC. PAD POURED FINISHED GRADE SEE NOTE 1 TO GRADE IN UNPAVED AREAS OR WHEN D.O.T. SPECIFICATIONS APPLY iv Q 3/8" GROUT ON INSIDE f— & OUTSIDE OF PRECAST RINGS N _w ------f 'e—T 2'-0"MIN. SEE NOTE 2 FLEXIBLE PLASTIC RAMNECK GASKET OR APPROVED EQUAL "A" =B" PACK WITH NON -SHRINKING GROUT GROUT & ASBESTOS CEMENT M.H. COUPLING FOR FIELD INSTALLATION NEOPRENE BOOT WITH �� •�•����] STAINLESS STEEL ACCESSORIES OR APPROVED EQUAL SHALL BE USED M FOR PRECAST MANHOLES SEE MANHOLE SCHD. SHALLOW MANHOLE DEPTH OF LESS THAN 5'-0" PIPE DIA. "A" "B" "C" BOT. SLAB "T" 8"-24" 4'-0" "8" 76„ 8" 30"-36" 5'-0" "8" 88" 10" 42"-48" 6'-0" 1181, 100" 12" TYPICAL MANHOLE DIMENSIONS NOTES: 1. MANHOLE FRAME & COVER WITH THE WORDS " SANITARY SEWER" CAST IN THE COVER. U.S. FOUNDRY 170 OR APPROVED EQUAL. 2. ALL CONCRETE MANHOLES TO BE 4000 P.S.I. TO MEET OR EXCEED ASTM C478 ALL CEMENT TO BE TYPE II ACID RESISTANT. REINFORCING AREA OF 0.02 SQ.IN/FT FOR WALL SECTION MIN. TO MEET OR EXEED ASTM A 185. 3. MANHOLES SHALL HAVE TWO COATS OF COAL TAR EPDXY COATING OR APPROVED EQUAL, APPLIED TO THE INTERIOR AND EXTERIOR SURFACE. THE FIRST COAT SHALL BE RED; THE SECOND COAT SHALL BE BLACK. MINIMUM COAT THICKNESS SHALL BE 8 MILS. 4. A MAXIMUM OF 2 LAYERS OF PRECAST CONCRETE RINGS, IF REQUIRED. 40�� Pi fRc� Fort Pierce Utilities Authority WASTEWATER PRECAST MANHOLE DEPTH OF S LESS THAN 5'-0" S - 2 DRAWN I APPROVED JDATE I REV. 12 12 # 5 SAR 3„ CONT. SURFACE COURSE a — 00 SUBGRADE NOTE: 3,000 P.S.I. CONCRETE AT 28 DAYS. FLUSH HEADER CURB DETAIL JOSEPH T. FRISCIA, RE, 9'I A OCr kin 41 AAQ to 00 0 � r M p Z a —/ L, M1 LLJ v ^ c J v Y W ZI-x V) Q � _ � L� O o n ° Z y Ld w 0 0 Ld E 3 d �// M L L. C'4 ?� N V) v 00 `O d J_ Q W C 0 LL_ Ld z CCD a Q Z W _J O 7'�/ l.L U 0 CD _Z Q In DRAWN R.W.F. CHECKED J.T,F, DATE 1-27-04 SCALE 1" = 20' JOB NO. 'J—n 5+ ^J SHEET 3 OF SHEETS 'GENERAL NOTES EROSION CONTROL Section VII (swpp narrative) 1.0 SITE DESCRIPTION 1.a Nature of Construction Activities Construction activities consist of the construction of one (1) warehouse building totaling 14,985 sq. ft. and 15,215 sq. ft. of pavement on 1.288 acres within the Kings Highway Industrial Park, St. Lucie County, Florida. l.b Sequence of Major Soil Disturbing Activities The following sequence of major activities shall be followed unless the contractor can propose an alternative that is equal or exceeds the erosion and sediment control practices described in this document, and is approved by the Engineer. The detailed sequence for the entire project can vary significantly from contractor to contractor. The contractor is responsible for providing a detailed sequence of construction for all construction activities. 1. Placement of all erosion control devices. 2. Clearing and grubbing, earthwork and excavation of ponds. 3. Storm sewer construction; all storm sewer shall be constructed in the upstream direction. 4. Earthwork associated with roadway, curb, subgrade, base and pavement. 5. Final seed and mulch and or sodding of the unpaved project area as called for in plans. 1.c Area Estimates Total site area: 1.288 acres Total Area to be Disturbed: 1.288 acres l.d Runoff Data 2.a.2 Structural Practices Temporary: Silt fence in accordance with Index 102 and Specification 104. Staked turbidity barrier in accordance with FDOT Index 103. Soil tracking prevention device in accordance with FDOT Index 106 or stabilized construction entrance constructed per FDOT index #106. All sediment controls shall be in place prior to any soil disturbing activity upstream of the control. 2.b Stormwater Management Stormwater will be conveyed in storm sewer system, cross details, and swales to Stormwater retention/detention ponds. 2.c Other Controls 2.c.1 Waste Disposal The contractor is solely responsible for documenting this portion of the SWPPP. 2.c.2 Off -Site Vehicle Tracking The contractor is responsible for documenting this portion of the SWPPP. 2.c.3 State and Local Regulations (Waste, Sanitary, and Septic) The contractor is solely responsible form documenting this portion of the SWPPP. 2.d State and Local Plans This project requires a modification to General Permit 56-00599-S 3. MAINTENANCE Runoff Coefficients: Before: POSED REPLACEMENT INTERVAL •._ ___.___ .._. --. „..-1- ... .........................�.... w "", mncoo wnc ' ."—" oonstion n operations. During: 0.30-0.81 Silt Fence In accordance with specification 6 Months 4. Novgot;an may require segmenting barrier Gunny canssmcrron operations. 5. For addWonaT information see Seotion 104 of The Standard Specifications. After: 0.81 Section 104. TUMMITY BARRIER APPUCATIM T U. Soils Data: The soils are silty fine sand to clean sands. The small sand particle size will Ponds Remove sediment when it becomes make the potential for erosion high. 0.4m (16") deep. SHEET FLOW Drainage Areas for Each Outfall: Straw Bales Remove sediment when it reaches 3 Months + 1 l.e Site Map 1/2 height of bales. BALES OF STRAW STAKED DOWN The contractor shall maintain rain gauges on -site and record daily rainfall. The contractor is The construction plans will substitute as site maps. Locations of the required information also responsible for documenting this portion of the SWPPP in the Section 104 Erosion Control are described below. Plan. Drainage Patterns: The drainage flow directions are shown on the Paving and Drainage Plan. Approximate Slopes: The slopes of the site can be seen on the Paving and Drainage plan and cross sections. Areas of Soil Disturbance: The areas to be disturbed are indicated on the plan. Any areas where permanent features are shown to be constructed above or below ground will be disturbed. Areas not to be disturbed: For the purpose of this plan, it is reasonable to say that all areas of the project will be disturbed during some phase of construction. Locations of Controls: The erosion control devices and locations are shown on the Paving and Drainage Plan. Areas to be stabilized: Temporary stabilization practices are also shown on the plans, if applicable. Areas of permanent stabilization are shown on the Paving and Drainage Plan. Surface Water: Surface water discharge is shown on the Paving and Drainage Plan. The surface water of the project will be routed to existing lake in the master drainage system on the southwest side of the property. 1.f Receiving Waters The surface waters of the project will be routed to existing lake in the master drainage system on the southwest side of the property. 2.0 CONTROLS 2.a Erosion and Sediment Controls The following defines general quantities for the sequence of construction and the use of stabilization and structural practices. The contractor is also responsible for documenting this portion of the SWPPP. The construction of this project is expected to last six months. Install stabilized construction entrances at all common areas where construction vehicles will be entering and exiting the construction site. The driveways shall be constructed of according to FDOT Design Standard Index #106. Install silt fences, Type III, around all ditch bottom inlets on the project, and the project perimeter. Filter cloth under the grates on catch basins may be used in lieu of a silt fence. Install staked turbidity barriers at the locations as indicated in the Paving and Drainage Plan (discharge points). At the outfall the swales located on the north, east and west sides of the property. 2.a.1 Stabilized Practices Temporary: Seed and mulch, and sod in accordance with Specification Section 104. Permanent: All stabilization practices shall be initiated as soon as practicable in portions of the site where construction activities have temporarily or permanently ceased, but in no case more than 14 days after the construction activity in that portion of the site has temporarily ceased. The contractor is also responsible for documenting this portion of the SWPPP. (KA31111 CK11*1*1-to 4. INSPECTION Qualified personnel shall inspect the following items at least once every seven calendar days within 24 hours of the end of a storm that is 0.50 inches or greater. Where sites have been finally stabilized, inspections shall be conducted at least once every month. Points of discharge to waters in the United States. Points of discharge to municipal separate storm systems. Disturbed areas of the site that have not been finally stabilized. Areas used for storage of materials that are exposed to precipitation. Structural controls. Stormwater management systems. Locations where vehicles enter or exit the site. 5. NON-STORMWATER DISCHARGES The contractor is required to submit a dewatering plan to SFWMD for approval prior to commencement of any construction activities that require dewatering. This plan shall include any stockpile areas and excavation areas. See SFWMD Rule 40 D-2 Consumptive Use of Water, Rule 40 D-3 Regulation Wells Specifying Requirements for Dewatering and ERP application Section E. subsection D Construction Schedule and Techniques. The contractor is responsible for documenting this portion of the SWPPP. If contaminated soil or groundwater is encountered, contact the District Hazardous Materials Coordinator. SINGLE ROW OF BALES OF STRAW TO BE PLACED PRIOR TO THE START OF ROUGH GRADING. P L A N V I E W WIRE TIE 2"x2" STAKES n 1-1/2' TO 2' IN n II THE GROUND i BALE TIES _T SECURELY BOUND BALES ANCHORING BALE` REQUIRED FOR DURABILITY ANCHORING BALES DETAIL NO. SCALE TYPE 0 SLT FENCE NOTE: DO NOT DEPLOY IN ANY MANNER THAT SILT FENCES WILL ACT AS A DAM ACROSS PERMANENT FLOWING WATERCOURSES. SILT FENCES ARE TO BE USED AT UPLAND LOCATIONS AND TURBITY BARRIERS USED AT PERMANENT BODIES OF WATER. r SILT FLOW -�AV TYPE ■ SLT FENCE NOTE: SPACING FOR TYPE III FENCE TO BE IN ACCORDANCE WITH CHART 1 , SHEET 1 OF 3 AND DITCH INSTALLATIONS AT DRAINAGE STRUCTURES SHEET 2OF3. TYPE III SILT FENCE PROTECTION AROUND DITCH BOTTOM INLET EROSION & SEDIMENT CONTROL PER FDOT INDEX 102 NOT TO SCALE 6'MAX POST OPTIONS: WOOD 2 1/2" MIN.DIA. WOOD 2"X4" OAK 1 1/2"X1 1/2" STEEL 1.33 LBS/FT MIN. r FILTER FABRIC (IN 200 OPTIONAL w PRINCIPAL POST POST > POSITION (CANTED POSITION 20" TOWARD FLOW) za FILTER FABRIC , SILT FLOW CONFORMANCE WITH ELEVATION SECTION SEC.985 FDOT SPEC.) NOTE: SILT FENCE TO BE PAID FOR UNDER THE CONTRACT UNIT PRICE FOR STAKED FENCE(L.F.) TYPE III SILT FENCE r rn M OI Z J V W D J v c Y W Z Z < U F o , O a ° LJ N w o v U of E I [p w z 3 M d Z 3 N w Li "' rn Li LiU CO° a J w a T fL a m Q n O Z O W Z_ w ct Iy O J Z lL O Z Q � � J W O O U W Q Of O 1— V) DRAWN MAF CHECKED JTF DATE 1-27-04 SCALE N.T.S. JOB NO. 03657 SHEET 4 OF SHEETS PLMW & MAT�FA, SCNbLl�� KEY QUAN, [ 0OfANICAL NAME CE 114 CONOCAVU5 Et:�CTU5 CI 16 CHpY5OPALANIU51CACO Ep �5 ELEA6NU5 pu%,�N5 IC 3 ILEX CA55M FM 0 POOOCAPM5 MACUPHYL25 QL 110 QV0 LAJrIFOI,IA QV 3 QVCIU5 VIFUNIANA 5M 7 5WMNIA MAHA60M VD 35 VIC WNUM Of5OM551MUM COMMON NAME GpE�N DuffONWDOn COCOPLLIM SILV�pTNOpN PMOON HOLLY JAPAN�5E YAW LAUpEI OAK LIVE OAK MAHOGANY 5VW VII3UkNUM ,I • 51z� C Hfl >f 5PP,> COWAIW j;- 2411 x18'' #-5 I � 20 0 10 LOT 38 2?AlI x 18' 1 I811 # 1 VACANT - I FUTURE LAND USE: IND 24" # GRAPHIC SCALE X 3 I ZONING: IL I ( IN FEET ) 1 inch = 20 ft. 12-14' x 5', 2-11211 TH C3 & C3 I 2411 x 18" # 3 r,,` -- \\ LOT 39 ��\ �— — — — \\ VACANT F TURE LAND USE: IND 12-1-1' x 5', 2-11 211 01-1 p & p �\ IMIIIT �..�` \ NINO:IL 12-14' x 5', 2-11211 WH 13 & C3 1 I1 .-- - \ -- wm— i't_I' —WM_. — _ —wm-- — _wm-- µN wm ------ ------ -= —--------------- ------- --------------------- i III ----- __ _ \ \ 29" x 1811 #3 ' I I i (.,,''LfMMERCIeAL CIRCLE as ------------------ 0 TpEE PLANTING bETAII � M11%1101 AM PLPNIING fP V5 A5 PaLOJJS- GN., 5fw - fPISIEi '7 GN., SFRID - 21PDLEfS 7 GPI-, 5" - 5 TPDLETS 5HpU6/ 6p0UNPCOV5p PLANTING [91 A% N15 ALL LANP5CAPE MAV\IAL TO P3 FLA.. #1 Op 3ETTEp PAHIA 50P A5 pEQIJKTP MA,&. IJCA Op 2CALYPTU5 MULCH (NO CYppE55) A5 pEQUIPEP TO 5" TIICU55 MINIMUM IN ALL ?I AI\. P3 P5 FULLY AUTOMAIC IppIGATION 5Y5TEM fO TOVIP2 ICO% COV��2 IN 15 MPH WINb ALL ppOHIPITEP 5PECIES 5HALL P3 PFMOVEP EpOM 51TE POOP, T0155UANCE OF CUIn\ FICATE OF OCCLP&CY NO INTRU51VE FOOT 5Y5TEM VEGETATION 9ik,!, 6E pLAaP WITHIN 12 FEET OF UYII-ITIE5. NO ,ANI25CAFIN6 51&1, DE PXF19 IN A MANNEp THAT W01P CpEATE CONFLICT5 WITH THE INTEmpEp OpEpAIOK ANP MAINTENANCE; OF ANY EX%NG U9 I,ITY, 50119 LOT 40 VACANT FUTURE LAND USE: IND ZONING: IL \It 1, 1\ 11 \ r, LOT 41 ` WAREHOUSE FUTURE LAND USE: IND ZONING: IL 1 1 jl� 1 1111 1 III I II I I III I I I I I I LOT 42 iLANUSE '0"US E: IND rI ��I O U 1L VATS: 12.12,2003 MWN: WAF CHECKEV: SCALE: I" - 20' rO.FCf No. 03-449 SO A SHEEP U OF I Permitting and Construction Plans for a New Facility for Coleman Floor Compan Circle Ft. Pierce, Florida Professionals: Owner Coleman Floor Company 3100 Tollview Drive Rolling Meadows, IL 60008 Architect The Architecture Company and Associates, Inc. 220 Freeman Street Longwood, FL 32750 Ph: (407) 332-8299 Fax: (407) 332-6669 License No: FL AA0002811 Mechanical - Electrical Enzineer Gast Engineering, Inc. 316 Cypress Landing Drive Longwood, FL 32779 Ph: (407) 774-3188 Fax: (407) License No: FL PE0038638 Contractor KNS Construction, Inc. 1465 Gene Street Winter Park, FL 32789 Ph: (407) 647-1234 Fax: License No: CGC040554 774-8059 (407)647-5234 Index of Construction Documents Sheet Title A-1 Foundation Plan - Finish Schedule A-2 Floor Plan - Reflected Ceiling Plan A-3 Elevations - Door and Window Schedule A-4 Sections P-1 Plumbing Floor Plan M-1 HVAC Floor Plan M-2 HVAC Notes and Schedules M-3 HVAC Details E-1 Power and Data Floor Plan E-2 Electrical Lighting Plan E-3 Electrical Notes, Riser and Schedules These drawings dated March 8, 2004 ST. LCCIE COtiTY FIRE DISTRICT REVIER ED FOR CONIFLIANCE SUBJECT TO FIELD INSPECTIONS SEE ATTACHED REVISION WE REV1E`VED BY: DATE: i REVIEWCD NO MUt`' � I. r,ONGRETE AND MASONRY NOTES: I ALL DETAILS AND SECTIONS SHOWN ON THE DRAWINGS ARE INTENDED TO BE TYPICAL AND SHALL BE CONSTRUED TO APPLY TO ANY SIMILAR SITUATION EL5EWHERE ON THE PROJECT, EXCEPT WHERE A DIFFERENT DETAIL 15 SHOWN. 2 CONCRETE MASONRY UNITS SHALL BE HOLLOW OR 50LID UNIT MASONRY IN ACCORDANCE WITH ASTM G90 OR C 145 AND SHALL HAVE A MINIMUM NET AREA COMPRESSIVE STRENGTH OF 1400 P51. 3 MORTAR SHALL BE EITHER TYPE M OR 5 IN ACCORDANCE WITH ASTM C 2-10. 4 GROUT SHALL HAVE A MAXIMUM COARSE AGGREGATE 51ZE OF 3/$" PLACED AT AN $ TO II INCH SLUMP AND HAVE A MINIMUM SPECIFIED COMPRE551VE STRENGTH OF 2000 P51 AT 2$ DAYS WHEN TESTED IN ACCORDANCE WITH A5TM C 1014, OR IN ACCORDANCE WITH A5TM C 476. 5 CONCRETE SHALL HAVE A MINIMUM SPECIFIED COMPRE551VE STRENGTH OF 2500 P5I AT 2$ DAYS. 6 REINFORCING STEEL SHALL BE MINIMUM GRADE 40 AND IDENTIFIED IN ACCORDANCE WITH A57M A 615, A 616, A 617, OR A -TO&. i JOINT REINFORCEMENT, ANCHORS, TIES, AND WIRE FABRIC SHALL CONFORM TO THE FOLLOWING STANDARDS: (I) ASTM A $2 FOR JOINT REINFORCEMENT AND WIRE ANCHORS AND TIES, (2) A5TM A 36 FOR PLATE, HEADED AND BENT BAR ANGHOR5. (3) A5TM A566 FOR SHEET METAL ANCHORS AND TIES. b ALL CONTINUOUS VERTICAL OR HORIZONTAL BARS IN FOOTINGS, FOUNDATION WALL5, SLABS AND OTHER CONCRETE SHALL BE LAP -SPLICED, WHERE NECESSARY OR DESIRABLE, BY WIRING TOGETHER IN CONTACT. LENGTH OF ALL LAPS SHALL BE 40-BAR DIAMETERS OR 24" MINIMUM, WHICHEVER 15 GREATER. q BED AND HEAD JOINTS SHALL BE 3/$" THICK. 10 THE BED JOINT OF THE STARTING COURSE PLACED OVER FOOTINGS SHALL BE PERMITTED TO VARY IN THICKNE55 FROM A MINIMUM OF 1/4" TO A MAXIMUM OF 5/4". II MASONRY WALLS SHALL BE RUNNING BOND CON5TRUGTION. q-GAGE (MINIMUM) HORIZONTAL JOINT REINFORCEMENT, IN ADDITION TO REQUIRED VERTICAL REINFORCEMENT, SHALL BE PLACED IN BED JOINTS AT NOT MORE THAN 16" O.G. 12 LONGITUDINAL WIRES OF JOINT REINFORCEMENT SHALL BE FULLY EMBEDDED IN MORTAR OR GROUT WITH A MIN. COVER OF 5/$" WHEN EXPOSED TO EARTH OR WEATHER E 1/2" WHEN NOT EXPOSED TO EARTH OR WEATHER, 13 REINFORCING STEEL SHALL BE NO. 5 BARS, UNLESS NOTED OTHERWISE. 14 FOR FOUNDATIONS MINIMUM CONCRETE COVER OVER REINFORCING BARS 544ALL BE 3" IN FOUNDATIONS WHERE THE CONCRETE 15 CAST AGAINST AND PERMANENTLY IN CONTACT WITH THE EARTH. GOLUM'N FOUNr�)A710N 5GHEDULE 5YM50L TYPE "A" "15" DEPTH REINFORCING ANCHOR 5OLT5 �j MAIN FRAME 3'-6" 3'-b" 2'-0" 5-#5 EACH WAY 4 - 5/4" DIA. A307 X 15" + 4" HK. 2 ENDWALL 2'-0" 2'-0" 1'-4" 3-#5 EACH WAY 4 - 5/4" DIA. A30-t X 12" + 2" HK. CORNER 2'-0" 2'-0" I'-4" 3-#5 EACH WAY 4 - 5/4" DIA. A307 X 12" + 2" HK. CENTER 3'-6" 3'-6" 2'-0" 5-#5 EACH WAY 4 - 5/4" DIA. A307 X 16" + 2" HK. NOTE5: I. VERIFY ANCHOR BOLT 51ZF-5 WITH METAL BUILDING MANUFACTURER 1. COLOR AND PATTERN OF MATERIALS ALL FLOORING 4 BASE TO BE PROVIDED BY OANER. AS SELECTED: R. ACOUSTICAL PANEL CLO: ARMSTRONG "CORTEOX" LAY -IN CEILING SYSTEM, 5GUAR.E EDGE,OR EGUAL. 11 @' �O r mn NOTE: ALL FILL SHOULD BE INORGANIC, NON- PLASTIC GRANULAR 501L (GLEAN SANDS). THE FILL SHOULD BE PLACED IN LEVEL LIFTS NOT TO EXCEED $" L005E THICKNESS. THE FILL SHOULD BE COMPACTED TO A MINIMUM q5% OF THE 501L'S MODIFIED PROCTOR MAXIMUM DRY DENSITY AS DETERMINED BY ASTM SPECIFICATION D-1557. IN -PLACE DENSITY TESTS SHOULD BE PERFORMED ON EACH LIFT TO VERIFY THAT THE RECOMMENDED DEGREE OF COMPACTION HAS BEEN ACHIEVED. FOUNDATION PLAN NOTE5: IQ PROVIDE 4" CONCRETE SLAB WITH 12" WIDE x $" DEEP THICKEN EDGE. SLAB TO SLOPE FOR POSITIVE DRAINAGE. 20 2,-0" WIDE X I'-O" DEEP CONCRETE FOOTING W/ 3-#5 EACH WAY. ® VERTICAL REINFORCING IS 5HOWN THUS ® . SEE 5ECTION5. DISTANCE BETWEEN FILLED CELLS TO BE NOT GREATER THAN $'-0" ® 3000 PSI 5" CONCRETE SLAB W/ 6x6-WI.4xAI.4 MM OR FIBER MESH REINFORCING OVER b MIL VAPOR BARRIER COVER COMPACTED POISONED SOIL TREATED FOR TERMITE INFESTATION. NOTE: DESIGN OF COLUMN BASE 8 TOP TO BE PRE-ENGINEERED BY STEEL FRAME SUPPLIER. INSTALL PER MFR'S SPECIFICATIONS. RAI #5 X 20' LONG ONE PIECE HAIRPIN TO BE BENT AROUND ANCHOR BOLTS L — — — J W/ 45 DEG. "V" BEND WHERE SHOWN. �OLUM'N FOUNI�)Afi I ON REFERENCE NO SCALE 744 I 10'-01, 4'-0` 10'-01, I 41 L. 10'-01, 4'-0" 1 10'-O" 74--0" I I I I 5 I I 7 I I I A-4 I I A-4 A-4 -- rl-- I r---- —�\ F---- -----� F------ ——� F-------- II II II I �I-J IIA I III II II Ii II CONTROL JOINT (TYPICAL) I III I II 2 II II $ II A-4 'Il 15'-7"1 31+6" 1 . 11'-2" F0 Y4 II II II II I 2 II A-4 Ir z O II o II z II o I III o � II I n IIIJ� II 2 III I L�---- -----J-L-- _-- _J 44'-$" TO CONTROL JOINT II6_2" 54" , I$'-O" 1 3'�6" I$'-O" �A L I s"f L-----J _u L------=---J—u L -------+-�--J u =---_ — I () I— -1 F t 37'-4" TO CONTROL JOINT A-4 44'-$" TO CONTROL JOINT 154'-$" O U N D A T 5GALE: 1/8" = 1'-O" ON FLAN THESE PLANS AP :l ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICACLE CODES. m REV 1510N5: O z m 'C O q O m � � 44 a O a cr3 M Q 4-;1 U O � m - cv� A rn cOD $r 0.J + o0 C4 ctz 0 V N � U w O a� O F 0 -1 o ro 11.0 0 c� o z �a" u PROJECT NO. 10304 DATE: MARCH 8, 2004 SHEET: A-1 DESIGN NOTES: THI5 PROJECT 15 IN COMPLIANCE WITH THE 2001 FLORIDA BUILDING CODE, CHAPTER I6, SECTION I6O6 FOR 120 MPH WIND LOADS, AND TABLE 1606.215 FOR THE EXTERIOR DOOR AND WINDOW WORK. SEE DOOR AND WINDOW SCHEDULES FOR WIND DESIGN PRESSURES. WIND DATA: WIND SPEED: 140 MPH WIND IMPORTANCE FACTOR: (IW) = 1.0 WIND EXPOSURE: "B" (FBC 1606.1b) WIND LOADS (FBG): WIND LOADS BASED ON PEG, SECTION 1606.2 WIND VELOCITY = 140 MPH, USE FACTOR 1.0 DESIGN CRITERIA: FLOOR LIVE LOAD (GENERAL AREA5): 100 P5F FLOOR LIVE LOAD LOAD (SERVICE BAY AREA): 125 P5F DEAD LOADS: FOLLOW 2001 FBG APPENDIX A, TABLES Al 6 A2 ROOF LIVE LOAD: 20 P5F SEE METAL BUILDING SHOP DRAWINGS FOR ADDITIONAL LOADS SPRINKLER NOTE: SPRINKLER PLAN SHOP DRAWINGS BY A FLORIDA LICENSED SPRINKLER CONTRACTOR ARE TO BE SUBMITTED FOR PERMITTING PRIOR TO INSTALLATION. INSULATION NOTE: INSULATION WHEN CONGEALED SHALL HAVE A FLAMESPREAD RATING OF NOT MORE THAN 15, AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 450 INSULATION WHEN EXPOSED SHALL HAVE A FLAME5PREAD RATING OF NOT MORE THAN 25, AND A SMOKE DEVELOPED RATING OF NOT MORE THAN 450 GENERAL NOTES ,AND REG2UIREMENTS: BUILDING DATA: BUILDING CODES: FLORIDA BUILDING CODE, 2001 EDITION LIFE SAFETY CODE - NFPA 101 - 2000 EDITION BUILDING GLASSIFIGATION: STORAGE 5-1 (OFFICE LE55 THAN 25%) BUILDING CONSTRUCTION TYPE: TYPE IV - UNPROTECTED - 5PRINKLERED BUILDING PHY5IGAL PROPERTIE5: WAREHOUSE AREA: II,114 50. FT. (-1a%) OFFICE AREA: 3,190 5Q. FT. (21%) TOTAL AREA: 14,904 50. FT. ALLOWABLE AREA: 45,000 50. FT. BUILDING OCCUPANT LOAD: WAREHOUSE AREA: 11,'114 50. FT. / 300 = 39 OCCUPANTS OFFICE AREA: 3,190 5G. FT. / 100 = 32 OCCUPANTS TOTAL OCCUPANT LOAD: it OCCUPANTS FLUM6I NO FIXTURE REM I REMENT5 BASED ON -TI OCCUPANTS TOTAL REG7UIREMENTS: 36 MEN / 36 WOMEN WATER CLOSETS LAVATORIES DRINKING FOUNTAINS SERVICE SINK5 MEN I I I I WOMEN —r I TOTAL PROVIDED HATER GL05ETS LAVATORIE5 DRINKING FOUNTAINS SERVICE 5INK5 MEN 2 2 2 I WOMEN I I I. ALL WORK SHALL COMPLY WITH THE CURRENT EDITION OF THE BUILDING 8. UNLE55 OTHERWISE INDICATED IN THESE SPECIFICATIONS, THE GENERAL CODE, AND ALL OTHER APPLICABLE CODES, RULES, AND REGULATIONS. CONTRACTOR, ALL SUBCONTRACTORS AND SUPPLIERS SHALL PROVIDE GUARANTEES BASED ON INDUSTRY RECOGNIZED STANDARDS FOR THEIR 2. The Architecture Company and Associates, Inc. SHALL BE THE "ARCHITECT PRODUCTS AND SERVICES, IN NO CASE SHALL THESE GUARANTEES REMAIN OF RECORD" AND SHALL RETAIN THE ORIGINAL CONSTRUCTION DOCUMENTS. IN EFFECT FOR LESS THAN ONE YEAR FROM THE DATE OF CERTIFICATE THE PLANS AND 5PEGIFIGATIONS ARE THE PROPERTY OF THE ARCHITECT AND OF OCCUPANCY. SHALL NOT BE USED OR REPRODUCED IN ANY FORM WITHOUT THE EXPRESS WRITTEN PERMISSION OF THE ARCHITECT AND/OR THE OWNER. a. SUBCONTRACTORS SHALL PROVIDE THE GENERAL CONTRACTOR WITH SUCH PLANS AND INFORMATION AS MAY BE REQUIRED FOR THE ISSUANCE 3. THE ARCHITECT SHALL NOT HAVE CONTROL OR GHAROE OF AND SHALL OF ACCEPTANCE CERTIFICATES. NOT BE RESPONSIBLE FOR CON5TRUCTION MEANS, METHODS, TEGHNIQUE5, 5EQUENCE5, OR PROCEDURES, OR FOR SAFETY PRECAUTIONS OR 10. THE GENERAL CONTRACTOR SHALL BE RESPON51BLF FOR OBTAINING PROGRAMS IN CONNECTION WITH THE WORK, FOR THE ACTS OR OMISSIONS ALL APPLICABLE PERMITS. OF THE CONTRACTOR, SUBGONTRAGTOR, OR ANY OTHER PERSONS PERFORMING ANY OF THE WORK, OR FOR THE FAILURE OF ANY OF THEM TO II. PROVIDE FIRE EXTINGUISHER HAVING A MINIMUM RATING OF 3-A, 40-56, CARRY OUT THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS. MOUNT AT 2'-a 1/2" A.F.F. AT LOCATIONS SHOWN ON PLAN. 4. DO NOT SCALE DRAWIN65. 12. CONTRACTORS SHALL BE LICENSED TO PROVIDE SERVICES WITHIN THE COMMUNITY OF THE AUTHORITY HAVING JURISDICTION. CONTRACTOR'S 5. THE 6ENERAL CONTRACTOR AND ALL SUBCONTRACTORS SHALL VERIFY SHALL ALSO INCLUDE NECESSARY INSURANCE COVERAGE TO INDEMNIFY ALL CONDITIONS, DETAILS, AND DIMENSIONS BEFORE PROCEEDING WITH THE THE OWNER, ARCHITECT, AND AGENT'S THEREOF FROM DAMAGES RESULTING WORK AND SHALL BE RESPONSIBLE FOR COORDINATION OF THE SAME, THE FROM THE PERFORMANCE OF THE CONTRACTOR'S WORK. ARCHITECT SHALL BE NOTIFIED OF ANY DISCREPANCIES. 13. INTERIOR FINISHES SHALL COMPLY WITH CHAPTER5, AND TABLE 803.3 6. JOB SUPERINTENDENT SHALL VERIFY ALL DIMENSIONS IN FIELD PRIOR TO FOR SPRINKLERED BUILDINGS. GOMMENCIN6 WORK. 14. CONTRACTORS SHALL PROVIDE ALL MATERIALS, EQUIPMENT, TOOLS -7. IT 15 INTENDED THAT ALL WORK BE FIRST QUALITY, AND ACCOMPLISHED TRANSPORTATION AND LABOR REQUIRED TO COMPLETE THE SCOPE OF IN A WORKMANLIKE MANNER BY SKILLED CRAFTSMEN USING ACCEPTED WORK IDENTIFIED WITHIN THESE GON5TRUGTION DOCUMENT5, PRACTICES AND METHODS APPROPRIATE TO THE TRADE INVOLVED. I R E F L E C T E D r-, E I L I N(5 F L A N 5GALE: I/8" = I'-V OFFICE AREA 5EE MECHANICAL AND ELECTRICAL 5HEEET5 FOR ADDTIONAL INFORMATION. O v DOCK Ell 5EE CIVIL 10'-0" 4'-O" 10'-0" 5 r A-4 6 ACCE55ORY 56HEOULE: �-4 (DPAPER TOWEL .DISPENSER: BDBRICK D-262 OR FOUAL O2 TOILET TISSUE DISPENSER: BOBRIGK B-2888 OR EQUAL - O MIRROR: BOBRICK 5-2a0 1550 OR EQUAL - ® 64RAB BARS: BOBRICK 5-4a0 SERIES OR EQUAL F g 18"X30" MIRROR 15" MIN. IF 56" MIN. I 1 6" 54" MIN. It 12 1 42 MIN. t PAPER TOWEL DI5PENSER 11" MIN. I 4 TP b Q Y I z z 6,: Z in p g r 2 2 !V SEE PLAN SEE PLAN p� �`- CLEARANCE SEE CIVIL DRAWINGS T O I L E T F IX T U R E 1� E T A L 5 FOR PAVING \ SCALE: I/2" = I'-O" 10'-0" 4'-0" 10'-0" 3'-8" 3'-4" MANEUVERING CLEARANCE A-4 A-4 115P 0 ^I PER FAGBG, FIG. 25 21 la 119E * IF, --1 F.E. I I I I d- I I I I I I I I I I I I I I I I i- O 2 1 I I I A-4 8 i A-4 o WAREHOU5E s - - I I IB I I I I - - _O FILE CABINETS 4 116 103 A-4 F E `r l 6 SUPPLIES m COUNTER q 2 BY OTHERS RECEPTION. Gll A-4 EAR FLOOR SPACE 102 FOR WATER CL05ET5 COVE D , COMPLYINO 100'-O" ENTR ® WI IX4ry 101 101 GhEAR FLOOR SPACE FOR SERVICE L VATORY (30"X45") COMPLYIN6 - 51NK W II-4.1a.3, FIG. 32. (TYPICAL) 10'-8�' 9'-10" ® O PARTITION PARTITION MEN 15 BY OTHERS BY OTHERS 115 O STEEL COL. 'a r Q _ W 4RE USE /� Q LJ BY MTL BLDG. MF-R. r 0 I Q OFFICE OPEN OF ICE, I ui N _ 111 4 H NDIGAP ACCESSIBLE 104 - 114 D2INKING FOUNTAIN `'p 4 IPE LOOR W/ 2" WIDE O PASSAGE O 1 LLOW PAINT W/ 5" FACE 113 n Nt m TO FAG OF STRIPE TO IND PATH Of� TRAVEL TO EXIT GATE 10 Oa 08 10I 106 0T r77 ILET BULKHD. 10'- " 10'-101-0..0'-O" 10' - HANDICAP ACCESSIBLE 12 ®8-O OFFICE OFFICE OFFICE OFFICDRINKING FOUNT IN KBREAK-N SUPPLIES m m 106110 F.E. ELEGr. 0 ' TT 00L zm�-� 13 ,� U U U I I $ I I t9Vaa' II" Io—1 I I I A-4 A-4 28'-8" 4'-0" b'-O" 4'-0" 6' P" 4'-0" 14'-8" 14'-8" 4'-8" 21'-6" 21'-b" 2 3 4 5 6 134'-e"THEsE PLANS AN!) w'. f'" '"���� PrbR� WALL LEGEND: ARE SUBJECT TO A ICY C RRECTIONS� L O O K F L A N METAL STUD WALLS REQUIRED BY FIELD INSPIECTC, Rs THA 5CALE: 1/5" = 1'-0" MASONRY WALLS MAY BE NECESSARY IN OR:ER TO INSULATED WALLS COMPLY WITH ALL � ne PLICA Z- CODES. REVISIONS: O �fJ L` °z ctz a O O m 6D cc O U ccyz O � � C � m U 4-a A a3 � I~ n\ O cc; C �t ^i\ 4 di U w 0 V O L cq F cq Q N Gd -- r) U +� O L i O CCS 0 O U U T N C) z I �a r�l PROJECT NO. 10504 DATE: MARCH &, 2004 SHEET: A-2 K NDOW SCHEDULE MARK HEAD 1�16T. ABOVE FRAME STOOL OLA55 DETAIL DE516N WIND PRESSURE REMARKS WIDTH HOT. MAT. COLOR TH4LK. ZYPE _ TINT A b'-O" 4'-0" 4'-b" ALUM. BRONZE NONE MF6R. IMPACT 6LAZIN6 r NONE 3/A-5 35.3/-5Z,.2 PSF FIXED B b'-O" 12'-O" 4'-b" ALUM. BRONZE NONE M66R. IMPACT 6LAZIN6 NONE 3/A-5 31.6/-34.6 P5F FIXED LINE OF TRUCK WELL SEE CIVIL DRANIN65 METAL FRAME v Ln r a c \ \ 26 6A. STEEL PRE -FINISHED METAL RIBBED 51PINO I 1 1 I ' I ! I I l i 1 I, I CONTROL JOINT W E S T E L E V A T I O N SCALE: 1/5" = I'-O" PAINTED GMU THIS ELEVATION i LINTEL NOTE ALL PRE -CAST LINTEL5 TO BE CA5T-GRETE OR EQUAL AND 16" WIDER THAN THE OPENING THEY SPAN. LINTEL5 DE516NA7ED PS ARE POWER STEEL LINTEL5. SEE SECTIONS. 12" D.A. PRE- FAB. COLUMN - METAL FRAME 3 5/5" METAL 57'JD5 (DOUBLE AT OPENIN65) 3 ANCHORS \ PER JAMB 6 m ' 2" 6YP BD. 8 GMU v \ \ \ 5PL! T-DACE 5.8 CAULK FIN15H WHERE 5HONN DOOR F R M E 5GALE: 5" = I'-O" 1 5/4" cv 5 '8" - J FROF I LES 120'-O" I GUTTER S D< / BY MTL.BLD 100'-O" --T I I SPLIT -FACE FIN15H CAULK 4 \ s V* \ n an F 2 3 D O O R F R A M E E L E V A T 1 O N S 5GALE: 1/4" = 1'-0" 6YP5UM BI ON MEUR' 5;, 13 AL' GO GUTTER d DOWNSPOUT BY MTL. BLD6. MF6R. CONTROL JOINT J C/ L) I F7 LL L L. V n I I l./ I `l SCALE: 1/8" = 1'-0" PAINTED GMU TH15 ELEVATION A=7A.1 A=APll P ;=Wl RY nL GA aT =I SCALE: I'•/a" = I'-O" 5FLLIT-FFArE 0M/i LEUU THIS ELEVATION 26 6A, 57EF-L PRE-FIN15HED 26 &A. ROOF PANEL BY METAL RIBBED SIDING / METAL BLD6. MF6R. Im N O R T H E L E V A T I O N 5GALE: I/8" = 1'-0" SPLIT -FACE GMU THIS ELEVATION OF TRUCK WELL------ j L-- -- --- - ---1---- ___ -j I_ DOOR SCHEDULE DOOR TYPE HARDWARE 5E7 SET #I NOTES; 1 1/2 PAIR 4" X 4" BUTT HINOE5 I. KEY PER TENANT'S INSTRUCTIONS. TEMPERED OLA55, - — - - PRIVACY LOCKSET W/ LEVER TYPE HANDLES 2. PAINTED DOORS TO HAVE ONE GOAT / - SET M2 PRIMER I ONE GOAT LATEX SATIN ENAMEL FIN15H. --- -- 1 1/2 PAIR 4" X 4" BUTT HINOE5 3, PROVIDE DOOR STOPS FOR DOORS ---------- LOCK5ET WITH THUMB LATCH WITHOUT CLOSERS. ------------- ALUMINUM THRESHOLD (MAX. 1/2" H6T.) 4. ALL SOLID GORE DOORS TO BE 1 3/4" -- --- SET #3 THICK. 1 1/2 PAIR 4" X 4" BUTT HIN6-S 5. STAINED DOORS TO HAVE TWO COATS - LOCK5ET WITH LEVER TYPE HANDLES URETHANE SATIN FINISH. --- --- - SET #4 1 1/2 PAIR 4" X 4" BUTT HIN6E5 - -- - — - LATCH5ET WITH LEVER TYPE HANDLES A B G D DOOR FRAME HARD— DESIGN MARK DOOR WARE WIND REMARKS DESG. TYPE HOT. WIDTH MAT. FINISH MAT'L. WIDTH JAMB 1 ELEV. SET PRESSURE 101 PAIR A 7-0" 51-0" ALUMINUM , BRONZE ALUMINUM 4 1/2" 1 1 2 33.1/-36.7 PSF CLOSER; WEATHERSTRIP 105 51N6LE C L66'-6 3'-O" 5G WOOD STAIN METAL 5 3/4" 2 2 5 106 SINGLE G 6 _5.. 5'-0" 5G WOOD STAIN METAL 5 3/4" 2 2 3 PLANS AND ALL PROPOSED WORK_ 106 51N6LE G 6'-b" 5'-0" 5C WOOD STAIN METAL 5 3/4" 2 2 3 ARE SUBJECT TO ANY CORRECTI W O-I SINGLE G b'-b" 3'-0" 5G WOOD STAIN METAL 5 5/4" 2 2 3 REQUIRED Y I"IP0INSPPE TORSTHAT 08 SINGLE G b'-b" 3'-O" 5C WOOD STAIN METAL 5 3/4" 2 2 3 MAY BE NECESSARY iN iRDER TQ I09 51N6LE G 6-b" 5'-0" 50 WOOD STAIN METAL 5 3/4" 2 2 4 coMPLY WITH ALLA 110 51N6LE B b'-b" 5'-0" 5C WOOD STAIN METAL 5 5/41, 2, 2 5 III SINGLE B (0'-b" 3'-0" 5C HOOD STAIN METAL 5 3/4" 2 2 3 112 51N6LE B 6'-8" 5'-0" 50 WOOD STAIN METAL 5 3/4" 2 2 1 CLOSER; WEATHERSTRIP; 515% "TOILET" W/ HANDICAP SYMBOL 115 51N6LE B 6'-b" 5'-O" SG WOOD STAIN METAL 5 5/4" 2 2 3 CLOSER; WEATHERSTRIP 113A 51N6LE B T-0" 5'-0.. IN5. MTL. PAINT METAL 5 1/21, 3 3 2 55.1/-5b.1 P5F CLOSER; WEATHERSTRIP 114 51N6LE B 6-6" 5`-0" 5C WOOD STAIN METAL 5 5/4" 2 2 1 CLOSER; SION: "WOMEN" IN/ HANDICAP SYMBOL 115 51N6LE B 6'-6" V-O" 5G WOOD STAIN METAL 5 3/4" 2 2 1 CLOSER; VON: "MEN" W/ HANDICAP SYMBOL 116 51N6LE B 6'-6" 3'-0.. 5C WOOD STAIN METAL 5 5/4" 2 2 3 111 51NOLE B 6'-b" 3'-0" 5C WOOD STAIN METAL 5 5/4" 2 2 5 116 SINGLE B 1'-0" 5'-0" IN5. MTL. PAINT METAL 5 1/21, 3 5 2 55.1/-56:7 P5F CLOSER WEATHERSTRIP IM ROLL -UP- D 0.-0.. 1 10'-O" MF6R. S0.0/-35.0 P5F 114A ROLL -UP D 10'-0" 10'-0" M176R. - 50.0/-53.0 P5F - IIC15 ROLL -UP D 12'-0" 10'-0" MF6R. 50.0/-33.0 PSF 1196 ROLL -UP D 12'-0" 10'-O" MF61R. 50.0/-55.0 PSF REV 15ION5: A5/15/04-51_06. DEPT. O � I z Cq �1 'C O q O C� c0 AbD cOG a00i � f� O � �u � � � O m U 4 ac O 00 1 z � cc� O � ` I a> � O •� fti V C) N a O CV F N Lin PROJECT NO. 10504 DATE: MARCH b, 2004 SHEET: . A-3 K NDOA SCHEDULE MARK HEAD HOT. ABOVE 100'-0" FRAME 5700L GLASS DETAIL DE51 GN WIND PRESSURE REMARKS WIDTH HOT. MAT. GOLOR THIGK. TYPE TINT A 8'-0" 4'-0" 4'-8" ALUM. BRONZE NONE 1/4" POL. PL. NONE 3/A-5 35.3/-38.2 PSF FIXED B 8'-o" 12'-0" 4'-8" ALUM. BRONZE NONE 1/4" POL FL. NONE 3/A-5 31b/-34.6 PSF FIXED i LINE OF TRUCK WELL SEE CIVIL DRANINC75 METAL FRAME E-1) O O R 50ALE: 5" = I'-O" WEST E VV IN I\ JV IINI =E\/Afi 't.� -A C,TFFI PGF_FIAIICllFf'f w SCALE: 1/8" = I'-O" PAINTED GMU THIS ELEVATION 3 ANCHOR5 PER JAMB 8" GMU In J '" w `SPLIT -FACE CAULK FINISH WHERE 5HOHN FRAME TEMPERED &LASS LINTEL NOTE: ALL PRE -CAST LINTELS TO BE CAST-CRETE OR EQUAL AND 16" WIDER THAN THE OPENING THEY SPAN. LINTELS DEVONATED PS ARE POWER STEEL LINTELS. SEE SECTIONS. 3 5/8" METAL STUDS METAL I (DOUBLE AT OPENIN65) FRAME, 1/2" GYP. BD. 12" D' FAB. 8" GMU N SPLIT -PAGE FIN15H (:D-- ,JA1�B FROF I LES 2 DOOR FAME SCALE: 1/4" = I'-0" 5 E L E V A T ONS CAULK 1/2" GYPSUM BOARD ON METAL FURRING PROVIDE "J" MOULD SHIM AS REQUIRED 1 3/4" X 4 1/2" ANODIZED ALUMINUM STOREFRONT CONSTRUCTION (BRONZE) ,::) (✓ L) I M 5GALE: /8" = 1'-0" 11F171 L_ E V I I I U IV PAINTED GMU THI5 ELEVATION 1= /�\ t I tz L t V /-\ I I U N SCALE: 1/8" = 1'-0" SPLIT -FACE GMU THI5 ELEVATION �L c& a^mac oeuoi n.r VVI\I lWL HIV IIN NORTH E E \ / ^ T ON �I ill. Y ,/�c\{` �`SII---------- --- J 5GALE: 115" = 1'-0" SPLIT -FACE GMU THIS ELEVATION DOOR S(f-,,HEF,)ULE DOOR TYPE HARDWARE SET SET #1 NOTES: 1 1/2 PAIR 4" X 4" BUTT HINGES I. KEY PER TENANT'S INSTRUCTIONS. TEMPERED OLA55 PRIVACY LOGKSET W/ LEVER TYPE HANDLES 2. PAINTED DOORS TO HAVE ONE GOAT SET #2 RIMER d ONE GOAT LATEX SATIN ENAMEL FINISH. 1 1/2 PAIR 4" X 4" BUTT HINOE5 3. PROVIDE DOOR STOP5 FOR DOORS LOCK5ET WITH THUMB LATCH WITHOUT CLOSER-5. ALUMINUM THRESHOLD (MAX. 1/2" HOT) 4. ALL SOLID GORE DOORS TO BE 1 5/4" SET #3 THICK. 1 1/2 PAIR 4" X 4" BUTT HINGES 5. STAINED DOORS TO HAVE TWO GOATS LOCKSET WITH LEVER TYPE HANDLES URETHANE SATIN FINISH. SET #4 1 1/2 PAIR 4" X 4" BUTT HINOE5 LATGHSET WITH LEVER TYPE HANDLES A B G D DOOR FRAME HARD- DESIGN MARK DOOR WARE WIND REMARKS DESC. TYPE HOT. WIDTH MAT. FINISH MAT'L. WIDTH JAMB ELEV. SET PRESSURE 101 PAIR A 7'-0" 3'-0" ALUMINUM BRONZE ALUMINUM 4 1/2" 1 1 2 33.1/-361 P5F CLOSER- HEATHER5TRIP 105 SINGLE C 6'-8" 3'-0" SG HOOD STAIN METAL 5 5/4" 2 2 3 10b 51N6LE C b'-8" 3'-0" 50 HOOD STAIN METAL 5 3/4" 2 2 3 IOb 51NOLE C 664" 3'-0" 50 HOOD STAIN METAL 5 5/4" 2 2 3 10"I 51NOLE C 6'-8" 3'-0" 50 HOOD. STAIN METAL 5 3/4" 2 2 3 106 SINGLE G 6'-8" V-O" 50 HOOD STAIN METAL 5 5/4" 2 2 3 104 51NOLE C 6'-8" V-0" SG HOOD STAIN METAL 5 3/4" 2 2 4 110 51N6LE B 6'-8" 3'-0., 50 HOOD STAIN METAL 5 3/4" 2 2 3 III 51N6LE B 6'-8" 3'-0" 50 HOOD STAIN METAL 5 5/4" 2 2 3 112 51N&LE B 6'-8" 3'-0.. 5G HOOD STAIN METAL 5 5/4" 2 2 1 GLO5ER; HEATHER5TRIP; 516N: "TOILET" H/ HANDICAP SYMBOL 113 SINGLE B 614" 3'-0.. 50 HOOD STAIN METAL 5 5/4" 2 2 3 CLOSER; HEATHERSTRIP 115A 51NISLE B T-0" 3'-0.. INS. MTL. PAINT METAL 5 1/2" 3 3 2 55.'I/-36.1I PSF CLOSER; HEATHER5TRIP 114 51NOLE B 614" 3'-0" 50 HOOD STAIN METAL 5 3/4" 2 2 1 CLOSER; SIGN: "WOMEN" YV HANDICAP SYMBOL 115 51N6LE B 6'-8" 3'-0" 5G HOOD STAIN METAL 5 5/4" 2 2 1 CLOSER; 516N: "MEN" NJ HANDICAP SYMBOL 116 51NOLE B 6'4" 3'-0" 50 HOOD STAIN METAL 5 5/4" 2 2 3 II? SINGLE B 64" V-0" 50 HOOD STAIN METAL 5 3/4" 2 2 3 116 SINGLE 5 '7'-0" V-0" INS. MTL. PAINT METAL 5 1/2" 3 3 2 33J/-361 P5F CLOSER; WEATHERSTRIP 114 ROLL -UP D 10'-0" 10'-0" MFISR. 50.0/-55.0 P5F 114A ROLL -UP D 10.-0.. 10'-0" W&R. 50.O/-33.0 PSF 114E ROLL -UP D 12'-0" 10'-0" MFSR. 50.O/-33.0 P5F 1148 ROLL -UP D 12'-0" 10'-0" MFGR. 30.0/-33.0 P517 REVISIONS: O °z L` Cal ctz a s ,d 0 ti ® Q� �W��++,, 0 Cc O Q' .a at U 4rA k F cal °O n \ O4-3 Cq �o V' � U w C) a� G4 m O cq F Gil � O U U _0 W (� %1 s, O .--4 RS z a 0 d Qf +� U w PROJECT NO. 10504 DATE: MARCH 8, 2004 SHEET: A-3 FLOOR LINE � 1o0-O „ 6 GMU BOND BEAM ROLL -UP DOOR - A5 REOV. #5 HORIZ - TIE TO CHAIR BLOCK REINFORGIN& PAVING-5EE CIVIL EN6INEERIN& W&5.x GROUT ALL CELLS FULL n 6" GMU W/ 1-05 FROM FOOTING TO BOND BEAM / a SEE FOUND. PLAN } PROVIDE KEEP �GOMPAGTED FILL n HOLES AT 46" O.G. DOCK PAVING -SEE SEE OTHER SECTIONS CIVIL DRAWIN55 I FOR DETAILS ------_-_ - _ 5 TOP OF q5'-4" FOOTING 5_#5 CONTINUOUS TOP AND BOTTOM �:; -I {� AIL ILL 1� T f5c-4 1 1/2" #3 HOOPS ® 12" O.G. 3'-O" SETA I N I NG WALL SE�TI ON oI�A4 3/4 - 11 4" CONCRETE SLAB (SEE FOUNDATION PLAN) FLOOR 100'-0" FOR ADDITIONAL INFORMATION CHAIR BLOCK LINE SEE SECTION 2 THIS SHEET #5 HORIZ- EXTEND 24" — INTO PERIMETER FT6. DOCK BUMPER AS REO'D. BY OWNER 61RT " 6" GMU W/-#5 FROM TOP OF 110'-O" FOOTING TO SLAB MA50NRY SEE FOUND. PLAN COMPACTED FILL • .I GROUT ALL CELLS FULL DOCK PAVIN5-5EE 6" R-19 INSULATION CIVIL DRAWIN65 = W/ VAPOR BARRIER 5-#5 CONTINUOUS c15'-4" [�)OCX WALL SECTION 3/4" = I'—O" GEILIN6 H6T. + 4" _nnnnnnnn ACOUSTICAL PANEL CEILII 1/2" GYP. BOARD PROVIDE R-II INSULATION WHERE SHOWN ON PLANS SEE FOUNDATION PLAN \ I00'-0 06 R-141 INSULATION VARIES ACOUSTICAL PANEL CEILING (OMIT GEILIN6 ON WAREHOUSE SIDE) B 5/6"(5TN25) METAL STUDS AT 16" O.G. GROUT FULL--.Q a SEE FIN15H SCHEDULE FOR 5A5E AND FLOOR FINISHES INTERIOR WALL SECTION b" SPLIT -FACE GMU (TURNED UP-510E- DOAN) AND &ROUTED FULL W/ 5000 P51 &ROUT ON POWERS STEEL 1-2-b" LINTEL. (FOLLOW MF6R5. SPECIFICS) 1/4" SHIM 5PAGE 1514 ALUr W/ I/ 1/2" &YP5UM BOARD ON 1 5/6" METAL STUDS AT 16" O.G. W/ R-6 INSULATION BETAEEN ALU1� I NUY ICI I NDON CONCRETE SLAB W/ bxb-WI.4xWl.4 AAM OR FIBER MESH REINFORCING OVER 6 MIL VAPOR BARRIER OVER P015ONED COMPACTED FILL 2-#5 CONTI UOU5 n � FERIMETER FOOTING 3/4" = 1'-0" 26 GA. ROOF PANEL BY METAL BLDG. MF6R. R-10, 5" VINYL FACED INSULATION ----------------------------- ROOF PURLIN STEEL FRAMING BY THE METAL BUILDING MANUFACTURER R-10, 3 VINYL FACED INSULATION �— &IRT5 AS SUPPLIED BY THE METAL BUILDING MANUFACTURER ANCHOR TO GMU WALL W/ 1/4" X 2" TAPCON5 AT 52" O.G. SEE FOUNDATION PLAN #5'5 EACH WAY SEE FOUNDATION PLAN h' SEC,TION ENDAALL SECTION EAVE TRIM BY MTL. BLDG. MFOR. VARIES 26 GA. STEEL PRE -FINISHED METAL RIBBED SIDING CPU 110'-0" BOND BEAM COURSE W/ 1- #5 CONTINUOUS 5" GMU OR SPLIT FACE GMU W/ 145 GROUTED CELL TO BOND BEAM. SEE PLANS FOR LOCATION. REVISIONS: R-10, 5" VINYL 26 GA. ROOF PANEL BY FACED INSULATION METAL BLDG. MFGR. 12 1/2 122'-0" O i GUTTER BY METAL ROOF PURLIN BUILDING MANUFACTURER °z m O � O � p CD ~ rJo � � 26 GA. STEEL PRE -FINISHED cj STEEL FRAMING BY THE METAL RIBBED SIDING o METAL BUILDING MANUFACTURER m COO �Qw U � n\ O i • o 4" DIA. DOWNSPOUT � (TYPICAL OF ALL) w • (Z V O O R-10, 5" VINYL F FACED INSULATION &IRIS AS BU SUPPLIED OF THE METAL BUILDING MANUFACTURER ANCHOR TO GMU WALL W/ 5/16" X 3" TALI AT 52" O.G. TOP OF GMU BOND BEAM COURSE W/ 1- #5 CONTINUOUS #5 X 20" LONG ONE PIECE HAIRPIN TO BE BENT AROUND ANCHOR BOLTS A/ 45 DEG. "V" BEND -------� CONCRETE SLAB SEE FOUNDATION PLAN \ FLOOR 100 -O LIB X x z - GRADE LINE #5'S EACH WAY----C SEE FOUNDATION PLAN i V�ALL SEC,710N C (1) .. O 0 8" GMU OR SPLIT FACE GMU Z a W/1-#5 GROUTED CELL TO BOND BEAM. SEE PLANS FOR LOCATION. r FLOOR �� LIN�� 100'-O" N Q GRADE LINE PROJECT NO. 10504 E PLANS AIND ALL more o wOPK DATE: MARCH 6, 2004 ARE SUBJECT TO ANY CORRECTIONS SHEET: REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN WF77' TO C>c : 4 ■ w 5/4" = 1'-0" 1 1/2" = I'-0" 3/4" = 1'-0" 5/4" = 1'-0" PLUMBING NOTES 1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE LOCAL CODES, RULES AND ORDINANCES. 2. ALL MATERIALS SHALL BE NEW. 3. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. 4. REQUIRED INSURANCE SHALL BE PROVIDED BY THE CONTRACTOR FOR PROTECTION AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF WORK. 5. CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMITS, FEES, INSPECTION AND TESTS. 6. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES, PIPING, EQUIPMENT, ETC. 7. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 8. CONTRACTOR SHALL GUARANTEE ALL MATERIALS & WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED. 9. PROVIDE 5 SETS OF SUBMITTALS FOR REVIEW BY ARCH/ENGR PRIOR TO PURCHASHING ANY EQUIPMENT OR MATERIALS. SUBMITTALS SHALL INCLUDE ALL ITEMS AND MATERIALS SUPPLIED BY CONTRACTOR. ANY EQUIPMENT OR MATERIALS INSTALLED WITHOUT REVIEWED SUBMITTALS SHALL BE REMOVED AND REINSTALL AT ARCH/ENGR DISCRESTION WITH NO ADDITIONAL COMPENSATION TO CONTRACTOR. 10. PROVIDE 2 SETS OF MAINTENANCE AND OPERATION MANUALS ON ALL MECHANICAL EQUIPMENT OR SYSTEMS. 11. VERIFY LOCATION, SIZE, INVERTS AND ALL EXISTING UTILITIES PRIOR TO BEGINNING CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES. 12. ALL FIXTURES MUST BE PROVIDED WITH READILY ACCESSIBLE CONTROL VALVES AND ACCESS PANELS. 13. DIELECTRIC COUPLINGS ARE REQUIRED BETWEEN ALL DISSIMILAR METAL IN PIPING AND EQUIPMENT CONNECTIONS. 14. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING. ALL ACCESS PANELS MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. 15. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL EQUIPMENT ROOMS. 16. ALL HOT WATER PIPES UNDER SINKS SHALL BE WRAPPED AND INSULATED WITH HANDI-SHIELD WRAP OR EQUAL. 17. INSULATE ALL HOT WATER LINES WITH - 1" THICK FIBERGLASS. 18. WATER PIPING AND FITTINGS SHALL BE SCHEDULE 40 "CPVC" WITH A RATING OF 100 PSI AT 180 DEG. F. 19. SOIL, WASTE, VENT, AND STORM PIPING SHALL BE SCHEDULE 40 PVC-DWV PIPE AND FITTINGS WITH NSF SEAL OF APPROVAL, ASTM D2665-82 (PVC) AND ASTM D2661-84 (DWV), AS MANUFACTURED BY G. S. R. , CHARLOTTE PLASTIC PIPE & FOUNDRY CO., OR EQUAL. MAKE PVC JOINTS WITH PVC-DWV SOLVENT CEMENT, ASTM D2564-88 "UNI-WELD" 1200 UP TO 6" PIPE DIAMETER. 20. CONTRACTOR SHALL VISIT THE JOB SITE AND THOROUGHLY FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS PRIOR TO BID. FIXTURE SCHEDULE PROVIDE FIXTURES AS LISTED BELOW OR EQUAL FROM THE FOLLOWING MANUFACTURES: AMERICAN STANDARD, KOHLER, ELJER, SLOAN, ZURN, CHICAGO FAUCETS, T&S, SPERZEL, OLSONITE, JOSAM, ACORN, ELKAY, HALSEY TAILOR, RHEEM, LOCHINVAR, A. 0. SMITH, WADE, SMITH. WC1 HANDICAPPED WATER CLOSET - WHITE AMER. STD. 2216.143 FLOOR MOUNTED, WITH TANK, 12" ROUGH -IN 1.6 GPF, ELONGATED OPEN FRONT, LESS COVER SPERZEL 50EWSSCH L1 HANDICAPPED LAVATORY, WALL HUNG - WHITE AMER STD 0356.015 FAUCET: 8" CENTERS, 5-3/8" SPOUT, 4" BLADE HANDLE CHICAGO 786-E3 FLOOR CARRIER WADE 400 JS JANITOR'S SINK, 2' X2' FLOOR FIAT TSBC-6012 S1 HANDICAPPED SINK SINGLE BOWL ELKAY LWR-2522-R 8" CENTERS, 8" SPOUT, 4" LEVER HANDLE CHICAGO 201-317 EWC ELECTRIC WATER COOLER ELKAY EBFSA-8 HB HOSE BIBB CHICAGO 387-E27 W/ VACUUM BREAKER WHA WATER HAMMER ARRESTER SMITH 5040 TP TRAP SEAL PRIMER VALVE JOSAM 88250 HD HUB DRAIN - W/FUNNEL STRAINER JOSAM 30000-E3 FCO FLOOR CLEANOUT, ADJUSTABLE COLLAR, JOSAM 5837OA-2 BRONZE TOP ECO EXTERIOR CLEANOUT BRONZE BODY AND PLUG JOSAM 58490-7 EWH ELECTRIC WATER HEATER RHEEM 61VP20S 20 GAL, 4.5 KW, 240/1 VAC `A�L - 3"VTR TO SANITARY MANHOLE 4" EC0 HB 1/2" 3L4�i EWC WC 3/4.,/x�� 1 \Jl'I\\ X L1/ WC1 f S1 1 /2" / I 1 /2" WATER ISOMETRIC NTS THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORI CTION5 REQUIRED BY FMLD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL t*PLICACLE CODES. m FLOOR PLAN - PLUMBING NORTH SCALE: 1/8'=1'-0' I f Na�1[-7C*7: O tc� L` t� cyD 3 O O C� .. 4D coo O U cvz m L.. � � O = U �Q w Q� •U s� 00 00 - c�T crz O � V W � 0 O cq F O O '., 0 F-� O ca 0 O U , h 7O Z 0 0 'mlt Ln0 0 � rnmm .. n I /R biNz 1„ V rl M / 4^0 i 0 x or, uD `J a WJ Ll K m O W _ M L61 F3 a Z 5n� Now V dL W 40 X Z Q ° CL W M PROJECT NO. 10504 r J DATE: MARCH 8, 2004 V SHEET: � J P_1 3- 2 7 -� y A/C LEGEND WS WALL SWITCH SD SMOKE DETECTOR OHEAT DETECTOR (FIRE STAT) OTHERMOSTAT 0 KEYED NOTE: EF 1 EQUIPMENT TAG: (ex.EF-1) SUPPLY AIR DIRECTION RETURN AIR DIRECTION U UNDER CUT DOOR 1" MIN UNLESS INDICATED ® INDICATES SUPPLY AIR INDICATES RETURN AIR INDICATES EXHAUST AIR CD GRILLE MARKER: INDICATES 12X12 TYPE "CD" GRILLE WITH 12"X12" 300 NECK, BALLANCE FOR 300 CFM. SUPPLY AIR GRILLE IN T-BAR CEILING SEE ARCHITECT'S REFLECTIVE CEILING PLAN ® SUPPLY AIR GRILLE SURFACE MOUNTED INTO CEILING TILE OR DRYWALL CEILING. ED WALL CAP DW DRYWELL SEE DETAIL FLEXIBLE DUCT: SIZE TO MATCH DIFFUSER NECK SIZE, UNLESS OTHERWISE INICATED. FLEX DUCT COLLAR W/OBD SPLITTER DAMPER 45 DEG TAP WITH DAMPER ♦= DUCT TRANSITION OPPOSED BLADE DAMPER (OBD) FIRE DAMPER WITH ACCESS DOOR CA - HVAC KEYED NOTES: 1. PROVIDE AN 8" RND OUTSIDE AIR DUCT TO WALLCAP. 2. PROVIDE A 6" RND EXHAUST DUCT TO ROOFCAP. m FLOOR PLAN - HVAC NORTH SCALE: 1/8"=1'-0" E PLANS AND ALL PROPOSED WORK SUBJECT TO ANY CORRECTIONS UIRED BY FIELD INSPECTORS THAT AY BE NECESSARY IN ORDER TO IDLY Vii I i LL APPLICABLE CODES, BUILDING DIVISION FppREVIEWED REVIEWEDBrYP }'�n� DATE THESE PLANS HAVE BEEN I INACCOPDANCE wiTH THE BUILDING CODE, 0 Z THESE PLANS AIND ALL PROPOSED WORK ARE SUBJECT TO A DIY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICACLE CODES, 0) It V Z rr W W Z Q Z W "7*sq 3-ZZ-0/7 REVISIONS: O lf� L` CV CY3 a 0-4 O O m y m O U O m � O m iS Q � cV 0? O SW cc j O cu V U �J �7 w O V O cq 7-1 L N z Q N O u PROJECT NO. 10504 DATE: MARCH 8, 2004 SHEET: M-1 MECHANICAL EQUIPMENT NOTES: GENERAL NOTES: 1. ALL MECHANICAL EQUIPMENT SHALL BE ARI & U.L. LISTED 1. THE CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, WHERE APPLICABLE AND RATED FOR THE REQUIRED SERVICE, EQUIPMENT, ACCESS PANELS, CONTROL SYSTEMS, DEVICES, PERMITS PRESSURES, TEMPERATURES, AND SHALL BE PROVIDED WITH ALL AND SERVICES NECESSARY FOR FURNISHING AND INSTALLING OF A NECESSARY TRANSFORMERS, SEALS, VALVES, CONNECTIONS, ETC. TO COMPLETE SERVICEABLE MECHANICAL SYSTEM. FUNCTION PROPERLY. 2. ALL MECHANICAL SYSTEMS ARE TO BE INSTALLED IN 2. ALL INSULATION WILL HAVE FIRE/SMOKE RATING LESS THAN ACCORDANCE WITH ALL APPLICABLE SECTIONS OF THE NFPA 25/50. STANDARDS, ANSI STANDARDS, THE LOCAL BUILDING CODE, PLANS AND SPECIFICATIONS. 3. PROVIDE A MIN. OF 3' CLEARANCE IN FRONT OF ALL 120-240 VOLT RATED PANELS AND DISCONNECTS. PROVIDE ADEQUATE SIDE 3. ALL MATERIALS SHALL BE NEW (UNLESS OTHERWISE INDICATED) CLEARANCE PER NEC. AND ANY DAMAGED EQUIPMENT SHALL BE REPLACED. 4. PROVIDE MOTOR STARTERS FOR ALL MOTORS. 4. CONTRACTOR WILL WARRANTY ALL MECHANICAL SYSTEMS, EQUIPMENT, PARTS AND LABOR FOR A PERIOD OF ONE (1) YEAR 5. PROVIDE IONIZATION TYPE AIR DUCT SMOKE DETECTORS WITH AFTER C.O. ACCESS DOORS WHERE INDICATED ON PLANS. ALL SMOKE DETECTORS SHALL BE BY ONE MANUFACTURE, COORDINATE VOLTAGE ETC. WITH 5. PROVIDE 6 SETS OF SUBMITTALS FOR REVIEW BY ARCH/ENGR ELECTRICAL CONTRACTOR AND FIRE ALARM SYSTEM BEFORE ORDERING. PRIOR TO PURCHASING ANY EQUIPMENT OR MATERIALS. SUBMITTALS UPON DETECTION, SMOKE DETECTORS SHALL SHUT DOWN ASSOCIATED SHALL INCLUDE ALL ITEMS AND MATERIALS SUPPLIED BY AIR MOVING EQUIPMENT AND ALL AIR MOVING EQUIPMENT SERVING CONTRACTOR. SUBMITTALS SHALL HAVE A SUMMARY SHEET SHOWING THAT COMMON PLENUM. CONNECT SMOKE DETECTOR TO BUILDING ALL SCHEDULED INFORMATION. ANY EQUIPMENT OR MATERIALS CENTRAL FIRE ALARM SYSTEM. IF BUILDING DOES NOT HAVE A INSTALLED WITHOUT REVIEWED SUBMITTALS SHALL BE REMOVED AND CENTRAL FIRE ALARM SYSTEM, PROVIDE REMOTE ANNUNCIATOR/TEST REINSTALL AT ARCH/ENGR DISCRETION WITH NO ADDITIONAL STATION WITH PIEZO ALERT AND LED, IN OCCUPIED AREA (PER NFPA COMPENSATION TO CONTRACTOR. 90A CH 4-4.4). SMOKE DETECTOR SHALL BE "SYSTEM SENSOR" - DH400ACDC WITH 21-390 ANNUNCIATOR OR EQUAL. 6. PROVIDE 2 SETS OF MAINTENANCE AND OPERATION MANUALS ON ALL MECHANICAL EQUIPMENT OR SYSTEMS. 6. PROVIDE FLEXIBLE DUCT CONNECTORS, RATED AS REQUIRED, TO ALL FANS, A/C UNITS, OR MECHANICAL EQUIPMENT, EXCEPT FANS USED FOR GREASE EXHAUST. 7. PROVIDE VIBRATION ISOLATORS ON ALL MECHANICAL EQUIPMENT AS CALLED FOR IN THE SPECIFICATIONS. IF NOT SPECIFIED, AS RECOMMENDED BY MANUFACTURER FOR QUIET AND VIBRATION FREE OPERATION. 8. PROVIDE A MIN. OF 10' CLEARANCE BETWEEN O/A INTAKES AND VTR OR EXHAUST OPENINGS. 9. HVAC CONTRACTOR SHALL TEST AND BALANCE ALL MECHANICAL EQUIPMENT AND AIR DEVICES, EXTRACTORS, DAMPERS, A/C UNITS, FANS, ETC. TO PROVIDE THE DESIGN QUANTITIES AS SHOWN ON THE PLANS OR SCHEDULES. 10. TEST AND BALANCE SHALL NOT BE STARTED UNLESS FILTERS ARE CLEAN. ANY BALANCING WORK COMPLETED WITH DIRTY FILTERS WILL HAVE TO BE REDONE. PRIOR TO STARTING BALANCING OPEN ALL DAMPERS IN DUCT SYSTEM AND AT GRILLS. ALL FLOW ADJUSTMENTS SHALL BE MADE AT THE BRANCH TAKEOFF, NOT AT THE GRILLS. ALL AIR FLOWS LISTED IN REPORT SHALL BE THE FINAL READINGS AFTER ALL ADJUSTMENTS ARE MADE. AFTER ALL AIR FLOWS ARE ADJUSTED THE TEST AND BALANCE CONTRACTOR SHALL TAKE AND RECORD THE FOLLOWING TEMPERATURES, PRESSURES, AND AMPERAGES: a) EVAPORATOR ENTERING AIR TEMPERATURE b) EVAPORATOR LEAVING AIR TEMPERATURE c) CONDENSER LEAVING AIR TEMPERATURE d) AMBIENT AIR TEMPERATURE e) REFRIGERANT SUCTION PRESSURE f) REFRIGERANT DISCHARGE PRESSURE g) UNIT VOLTAGE h) COMPRESSOR AMPERAGE i) EVAPORATOR FAN MOTOR AMPERAGE j) CONDENSER FAN MOTOR AMPERAGE 11. RUN CONDENSATE DRAINS TO DRYWELL, AS REQUIRED. CONDENSATE DRAINS SHALL BE A, MINIMUM OF 3/4". CONDENSATE DRAINS SHALL BE SCHEDULE 40 PVC, WITH 1/2" ARMAFLEX INSULATION. 12. MOUNT ALL EQUIPMENT FOR WIND LOADS AND MOUNTING HEIGHTS AS REQUIRED BY LOCAL CODES. 13. ALL PIPING AND DUCTWORK SHALL BE SLEEVED THRU WALLS, BEAMS, SLABS, ETC, AS REQUIRED AND COORDINATED WITH THE STRUCTURAL ENGINEER. PROVIDE NECESSARY TRANSITIONS AS REQUIRED FOR DUCTWORK INSTALLATION. 14. CONTRACTOR WILL PROTECT THE AIR-CONDITIONING UNITS AND DUCTWORK IN THE FOLLOWING MANNER. PRE -FILTER ALL RETURN AIR GRILLES WITH ROLL TYPE FILTER MEDIA AND REPLACE IT AS NEEDED THROUGHOUT THE CONSTRUCTION PERIOD. EQUIPMENT MUST NOT BE STARTED FOR ANY PURPOSE UNTIL THE DRYWALL SANDING, ETC. IS COMPLETED. ONCE DRYWALL SANDING IS COMPLETED, THE UNITS MAY BE STARTED ONCE THE ABOVE PRE -FILTERING IS COMPLETED. COORDINATION NOTES: 1. A/C CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE HIS WORK FOR SIZE, LOCATION, CLEARANCE, ACCESS AND ELECTRICAL CHARACTERISTICS WITH ALL OTHER TRADES AND TO PROVIDE SHOP DRAWINGS TO THE ENGINEER FOR REVIEW BEFORE INSTALLATION OF DUCTWORK OR EQUIPMENT. SHOP DRAWING WILL INCLUDE BEAM OR STRUCTURE ELEVATION & REQUIRED EQUIPMENT ACCESS AREAS. 2. WALL, ROOF, AND CEILING OPENINGS INDICATED ON CONTRACTOR DRAWINGS ARE NOMINAL DIMENSIONS ONLY AND ALL DUCT, PIPE OR EQUIPMENT PENETRATIONS SHALL BE SLEEVED AND FIRE RATED AS REQUIRED, ADJUST OPENINGS 3. COORDINATE LOCATION OF CEILING DIFFUSERS, GRILLES AND REGISTERS IN THE FIELD WITH LIGHTS, SPRINKLERS AND ARCHITECTURAL ELEMENTS. 4. COORDINATE LOCATION OF A/C UNITS, THERMOSTATS, FANS AND DUCTWORK WITH BUILDING STRUCTURE AND OTHER TRADES SO THAT NO INTERFERENCES OCCUR. 5. IN GENERAL, DUCT OFFSETS HAVE NOT BEEN SHOWN. A/C CONTRACTOR TO COORDINATE THESE AS REQUIRED. 6. MECHANICAL PLANS IN GENERAL, ARE DIAGRAMMATIC IN NATURE, AND ARE TO BE READ IN CONJUNCTION WITH ARCH. PLUMBING, ELECTRICAL AND STRUCTURAL PLANS. DUCT AND PIPING OFFSETS, BENDS AND TRANSITIONS WILL BE REQUIRED TO PROVIDE AND INSTALL A COMPLETE FUNCTIONAL SYSTEM AND SHALL BE PROVIDED BY THE CONTRACTOR AT NO ADDITIONAL COST TO THE OWNER. 7. ALL LOUVERS, GRILLES, PIPING, ETC. SHALL BE PAINTED TO MATCH SURROUNDING COLOR AND TEXTURES AS REQUIRED BY ARCHITECT. VERIFY COLOR AND TEXTURE WITH ARCHITECT. PAINT ALL EXPOSED MECHANICAL EQUIPMENT WITH BENJAMIN MOORE EPDXY ENAMEL 182. 8. ALL OPENINGS IN BUILDING STRUCTURE, FOR DUCTWORK, PIPING, ETC. TO BE 1/2" LARGER (ON ALL SIDES) THEN THE OUTSIDE DIMENSIONS. FILL VOIDS WITH FIRE RETARDANT SILICONE FOAM (I.E. CHASE -FOAM CTC PR-855 BY CHASE TECHNOLOGY CORP.). DUCTWORK & ACCESSORIES NOTES : 1. ALL DUCTWORK SHALL BE AS FOLLOWS OR APPROVED EQUAL: a) SUPPLY - MANVILLE SUPERDUCT 1-1/2" 3/4 LB FIBERGLASS DUCTBOARD R=6. 0. b) RETURN - MANVILLE SUPERDUCT 1-1/2" 3/4 LB FIBERGLASS DUCTBOARD R=6. 0. c) FLEX DUCT - THERMAFLEX G-KM R=6.0. d) O/A - GALV. SHEETMETAL W/ 1" 3/4 LB WRAP e) EXHAUST - GALV. SHEETMETAL 2. ASSEMBLE, INSTALL, AND SEAL DUCTWORK IN ACCORDANCE WITH SMACNA "HVAC DUCT CONSTRUCTION STANDARD". UNLESS OTHERWISE NOTED ON PLANS CONSTRUCT DUCTWORK TO 2" DUCT CLASS, SEAL CLASS "B", AND LEAKAGE CLASS 12. 3. SEAL ALL SHEETMETAL DUCTS JOINTS WITH RCD #8 MASTIC. 4. MAKE JOINTS FOR DUCT WRAP AND DUCTBOARD WITH GLASS FABRIC AND VAPOR BARRIER COATING TO 30 MILL DRY FILM THICKNESS, RCD #9. 5. CONTRACTOR SHALL PROTECT ALL FIBERGLASS INSULATION PRODUCTS FROM DAMAGE. INSULATION PRODUCTS SHALL NOT BE ALLOWED TO GET WET. INSULATION DAMAGED AS A RESULT OF MOISTURE, VANDALISM, OR CONSTRUCTION TRAFFIC SHALL BE REPLACED. 6. PROVIDE RUSKIN "DIBD2" TYPE "B" FIRE DAMPERS (UL 555 DYNAMIC RATING) WITH ACCESS DOORS WHERE INDICATED ON PLANS. 7. USE RADIUS RECTANGULAR FITTINGS OR TURNING VANES IN ALL SUPPLY DUCT ELBOWS, CONICAL BRANCH TAKE -OFFS, SPLITTER DAMPERS WHERE INDICATED ON DRAWINGS AND VOLUME CONTROL EXTRACTORS IN ALL BRANCH DUCTS OR DIFFUSER CONNECTIONS. 8. ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS. 9. PLANS ARE DIAGRAMMATIC. IN GENERAL DUCT OFFSETS HAVE NOT BEEN SHOWN. A/C CONTRACTOR SHALL COORDINATE THESE AS REQUIRED WITH BUILDING STRUCTURE AND OTHER TRADES. 10. TERMINAL AIR DISTRIBUTION DEVICES SHALL BE AS FOLLOWS OR APPROVED EQUAL: a) CD CEILING DIFFUSER MODEL TDCA-AA, 24X24 MODULE TYPE 3 BORDER, WITH SQUARE OR ROUND NECK. PROVIDE 4-WAY AIR PATTERNS UNLESS OTHERWISE SHOWN ON PLANS. b) RAG RETURN AIR GRILLE MODEL 350FL. 11. PAINT DUCTWORK VISIBLE BEHIND AIR DISTRIBUTION DEVICES MATTE BLACK. LANE AND ALL PADP0410 WORW UBJECT TO ANY CME'elICNs IED BY FIELD INBPOTOR,'I O BE NECESSARY IN tJRM 10 n ligns COMPLY WI-M ALL APPLICASLI CODES: SPLIT SYSTEM SCHEDULE MARK AH/CU-1 AH/CU-2 SYSTEM TYPE CLG/ELEC HTG CLG/ELEC HTG AREA SERVED SEE SEE PLANS PLANS AIR HANDLER DATA! MANUFACTURER TRANE TRANE MODEL NO. TWE060C TWE050C WEIGHT (LBS) 200 200 CABINET TYPE (VERT/HORIZ) VERT VERT CFM TOTAL 1700 1775 CFM 0. A. 250 200 E. S. P. W. G. ) .5 .5 H. P. /F. L. A. 50/5. 9 50/5. 9 RPM ( SPEED) (MED) (MED) ELECTRIC HEATER KW 7.2 7.2 HEATER STAGES 1 1 HEAT LOCATION (DUCT/INT.) INTERNAL INTERNAL VOLTAGE (V/PH/60) 208/1/60 208/1/60 POWER CONN. (SINGLE/MULTI) SINGLE SINGLE MAX FUSE 60 60 CONDENSING UNIT DATA: MANUFACTURER TRANE TRANE MODEL NO. TTR060C TTR060C WEIGHT (LBS) 260 260 COMP. QTY 1 1 COMP. F. L. A. EA. 29. 1 29. 1 COMP. L. R. A. EA. 141.0 141.0 FAN QTY 1 1 COND FAN H. P. ( EA) .25 .25 COND FAN F. L. A. ( EA) 1. 9 1. 9 VOLTAGE (V/PH/60) 208/1/60 208/1/60 MCA 38.0 38.0 MAX FUSE 60 60 SYSTEM DATA 95 DEG F AMB : TOTAL COOLING (TMBH) 58.2 58.2 SENSIBLE CAPACITY (SMBH 39.2 39.2 ENT. A I R TEMP. (F) (DB WB 8D 67 80/67 COMPRESSOR STAGES %( 0 100 0/100 HEATPUMP CAPACITY �MBH) - - A. R. I. SYSTEM EFFICIENCIES: SEER HSPF 10. 20/1.0 10. 20/1. 0 EER/IPLV/COP - - REMARKS: SEE BELOW SEE BELOW SPLIT SYSTEM NOTES: 1. SELECTION BASED ON TRANE, PROVIDE EQUAL BY CARRIER, McQUAY, YORK, RHEEM, OR RUUD. 2. ALL UNITS MUST BE UL LISTED AND ARI CERTIFIED. 3. PROVIDE LIQUID LINE FILTER -DRYER SIGHT -GLASS AND SOLENOID VALVE. 4. PROVIDE SERVICE VALVES ON SUCTION AND LIQUID LINES. 5. PROVIDE ONE YEAR WARRANTY ON UNIT, 5 YEAR WARRANTY ON COMPRESSOR. 6. PROVIDE BUILT-IN FACTORY WIRED UL ELECTRIC HEATER W/HEATER CONTROL PACKAGE. 7. PROVIDE PROPER VIBRATION ISOLATION AS PER DRAWINGS AND SPECIFICATION, IF NOT SHOWN, AS PER MANUFACTURER'S RECOMMENDATION. 8. SIZE AND RUN COPPER REFRIGERANT PIPING AS PER MANUFACTURERS PUBLISHED RECOMMENDATIONS TO PROVIDE LISTED SENSIBLE AND TOTAL MBH. 9. PROVIDE AUX. DRAIN PAN AND A/C CONDENSATE DRAIN LINES WITH A TRAP AND CLEANOUT. 10. PROVIDE 3/8" THICK ARMAFLEX FIRE RETARDANT PIPING INSULATION ON A/C CONDENSATE LINES, 1/2" THICK ON REFRIGERANT SUCTION LINES 2-5/8" AND SMALLER, AND 3/4" ON ALL LINES LARGER THAN 2-5/8". PROVIDE AN ALUMINUM JACKET TO PROTECT THE INSULATION ON ALL PIPING OUTDOORS AND IN MECHANICAL ROOMS. OVERLAP END OF JACKET BY THREE INCHES AND SECURE WITH STAINLESS STEEL BANDING. 11. PROVIDE TWO SETS OF 1" 40% FILTERS TRI-DIM ES60M THROW AWAY FILTERS (800 937-1450). 12. E. S. P. DOES NOT INCLUDE COIL OR CABINET LOSSES. 13. UNLESS OTHERWISE NOTED CAPACITIES AND EFFICIENCIES ARE AT ARI CONDITIONS: 14. COORDINATE WITH ELECTRICAL CONTRACTOR BEFORE BIDDING OR ORDERING ANY EQUIPMENT. 15. SEE GENERAL, AIR CONDITIONING, DUCTWORK, AND COORDINATION NOTES FOR OTHER FIELD SUPPLIED ITEMS. 16. PROVIDE A/C UNITS WITH HEATING AND COOLING THERMOSTAT WITH FAN ON -OFF -AUTO SWITCH. . SET STAT FOR FAN IN AUTO MODE. FAN SHALL NOT RUN UNLESS THE COMPRESSOR OR HEATER IS ON. FAN SCHEDULE MARK EF-1, 2, 3 QUANITY 3 TYPE CEILING SERVICE RESTROOMS MANUFACTURE GREENHECK MODEL NO. SP-6 WEIGHT 10 AIR DATA: C. F. M. 75 S. P. 25 RPM 1500 B. H. P. ( WATTS) (40) TIP SPEED - SONES 3.4 MOTOR DATA: DRIVE DIRECT R. P. M. 1500 H. P. ( WATTS) (40) VOLT-PH-HZ 120/1/60 REMARKS 1, 2, 3, 4 FAN NOTES 1. SELECTION BASED ON GREENHECK, PROVIDE EQUAL BY PENN, LORAN COOK, OR ACME. 2. PROVIDE MOTOR STARTERS AND ALL ASSOCIATED CONTROLS ON ALL FANS. 3. PROVIDE BACK DRAFT DAMPER FOR ALL EXHAUST. 4. SWITCH WITH LIGHTS. r174-vigr#04 O C` Cu 3 � O U q O b0 c�D m O U m m � m Q� O cq Sn\ rA ccrzO ^IW O a- O C) U V w �v w • � CCS \z V O O cq f� cq O O �b o C� ~ �Ty it w 0 U V O W d Z m z �a 0 �1 n o ?-1 O 4. (b00 a) w n � NYC Vn z ZnQ o"� O mxo L.L ` :3 o L) W 0 d30o H Lu _ U M Z � U Z zn� gnr f Now r ix zOLaVJ z U0 Q e xa W on PROJECT NO. 10904 r DATE: MARCH 8, 2004 SHOT: � M-2 U-NAMPIM OUTSIDE AIR DUCT VOLUME DAMPER RETURN AIR DUCT FLEXIBLE � CONNECTION \ FIN. FLOOR ' C' CHANNEL SUPPORT AS REW D AIR c C WHITE CEILING GRILL #]1 WIRE NOTES: 1.- PROVIDE BACKDRAFT DAMPER 2.- SUPPORT FAN FROM STRUCTURE -SMOKE DETECTOR —FIN. CEILING SUPPLY AIR DUCT FLEXIBLE CONNECTION AIR HANDLING UNIT — R/A PLENUM BASE VIBRATION ISOLATION AIL SHEETMETAL DUCTWORK CABINET CEILING FAN DETAIL N. T. S. FANCEIL3 SAMPLING TUBE ` `-INSULATION PL AIRFLO� INSULATED ACCESS PANEL SMOKE DETECTOR ENSURE SMOKE DETECTOR HOUSING BAFFLE IS IN PLACE REPLACE HOUSING COVER PROMPTLY FOLLOWING SERVICING TO AVOID FALSE ALARMS SCHARGE TUBE \-NEOPRENE GASKET —SMOKE DETECTOR HOUSING PROVIDE ACCESS FOR REMOVING SAMPLING TUBES. NOTES: 1. INSTALL IN STRICT ACCORDANCE WITH MANUFACTURER'S INSTALLATION INSTRUCTION. 2. COORDINATE VOLTAGE AND TYPE WITH ELECTRICAL AND FIRE ALARM CONTRACTORS. 3. SAMPLING TUBE MUST BE INSTALLED ACROSS GREATEST DUCT DIMENSION. DUCT SMOKE DETECTOR DETAIL NTS SDET-1 M-4 5 M-4 9 M-4 NOTE: 1. ALL REFRIGERANT PIPE AND INSULATION SHALL BE INSTALLED SECTION BY SECTION AT THE SAME TIME AND IN CONJUNCTION WITH THE INSTALLATION OF THE PVC REFRIGERANT PIPE CHASE. 2. ALL REFRIGERANT PIPING INSTALLED IN THE PVC CHASE SHALL BE CAPPED AND PRESSURE TESTED ACCORDING TO SPECIFICATIONS PRIOR TO INSTALLATION OF CONCRETE SLAB. 3. ANCHOR CONDENSING UNIT TO CONCRETE SLAB AS FOLLOWS. PROVIDE ONE 1-1/2" 16 GA GALV. STEEL STRAP EVERY 12"O.C. SECURE STRAP TO UNIT WITH WITH (2) 3/4"#10 SHEETMETAL SCREWS. SECURE STRAP TO CONCRETE SLAB WITH RED HEADS. CONDENSING UNIT (TO BE INSTALLED ON 1" THICK NEOPRENE ISO- LATION PADS) FLEXIBLE SEAL TIGHT ATTACHED TO ELEC- TRICAL CONDUIT ELECTRICAL CONDUIT FOR LOW VOLTAGE CONTROL WIRING GRADE PIPE CHART SUCTION PIPE SIZE PVC REFRIGERANT PIPE CHASE SIZE 1-7 8" TO 2-5 8" 6" 3-18 TO 4-1 8 8 CONCRETE SLAB REFRIGERANT PIPES HARD -DRAWN COPPER PVC REFRIGERANT PIPE CHASE.CUT OFF 1" ABOVE GRADE AND SEAL ENDS WITH WIRE MESH SCREEN CONDENSING UNIT PIPING DETAIL N. T. S. CU-PC-WM ANNEL DUCT TAIL MMNUINU LL I HIL NOTE: ALL STRAP SHALL BE A MINIMUM OF 1-1/2.26 GA GALVINIZED STEEL. WITH A 6 FT MAXIMUM SPACING. METHODS OF HANGING DUCTS N. T. S. HANGDUCT MIN. 4" HIGH VENT MIN MAX SEE SPECIFICATIONS FOR PIPE TYPE AND INSULATION REQUIREMENTS A/C UNIT COIL CONDENSATE DRAIN PAN EXTEND CONDENSATE LINE FULL SIZE FROM UNIT CONDENSATE DRAIN CONNECTION (3/4" MINIMUM) CLEANOUT WITH THREADED PIPE CAP N CONDENSATE TRAP DETAIL 3 4 m- NOTE: ALL STRAP SHALL BE A MINIMUM OF 1-1/2", 26 GA GALVINIZED STEEL. HANGER WIRE SHALL BE A MINIMUM OF 22 GA. HANGER WIRE OR STRAP 10'-0" MAX DISTANCE BETWEEN SUPPORTS. MAX. SAG 1/2" PER FOOT SPIN -IN W/ OF SUPPORT SPACING. MANUAL DAMPER 6 AIR SCOOP 1-1/2'• GALV. STEEL BAND CLAMP TO MATCH DUCT RIGID AIR DUCT: DIAMETER SEE "METHODS OF HANGING DUCTS" FOR REQUIREMENTS INSULATED FLEXIBLE DUCT AIR DIFFUSER 24" DIAMETER MIN. CORROGATED BLACK PLASTIC PIPE , no 0 0 0 'IN vo p o0o v` n op in o n p �p n on �o n op o�non D o n o o n vp nn o00 0 p p o p p D n O �p in v n on vo on � e p lo�n op o lap n n la 0 0 0 0 o vo n o00 0 'an o p In o In o Ionia � �n op "o n n � o o npop n o on o 0 in n o npoQopoo $ mono 0 y n G p n 'a n p a n n J DRYWELL DETAIL N. T. S. DRYWELL4 INSULATED PLENUM BOX 0 Llo ALTERNATE FOR LOW CLEARANCE :lfm FLOW 3/4" CRUSHED ROCK INSULATED DUCT M-4 6' SHEETMETAL EXTENSION COLLAR SUSPENDED T-BAR CEILING GRID rI LAY -IN ACUSTICAL 26 GAUGE COLLAR CEILING TILE FIN. CILING-,' INSTALL STAINLESS STEEL DUCT SUPPLY AIR GRILLE CLAMPS ON BOTH INNER AND OUTER JACKETS. SEAL INNER JACKET AIR TIGHT WITH MASTIC. NYLON DUCT CLAMPS MAY BE USED IN NON PLENUM AREAS. s FLEXIBLE DUCT DETAIL MM-4 SUPPLY AIR GRILLE N. T. C. FLEXDUCT M�4 _ N. T. S. CD-1 THESE PLANS AND ALL M40POSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH PlL APPLICABLE CODES. M-4 O L` Cv a � O cs N O Cn be CID Y as 0 O 1 eq .5 a m m � = 'd cis U •'r 4­1 Q 0 U m m I 00 n \ O �0 N L` 0 � U f•1 \ w �J w Q •� b V rr� W cq w Iz "d U d 0 a �� 4 F� F4 z �' z m 0 a — 'LOo m aoD m n (� U r+i PL4 .. N ^ M P z dno Q� Z oN F a_ r� 0 x� (0v " v jz Q W rc co 0 W M H Z Q V _ Z Zn� g ^ iti -� (n0U �vo co V W t� 0 7 0 `ray` L Q W "' PRO-ECT NO. 10WA r I� DATE: MARGFf 8, 2004 V SHEET: M-3 SYMBOLS FLUORESCENT LIGHTING FIXTURE - CEILING MOUNTED O FLUORESCENT, INCANDESCENT OR HI➢ DOWNLIGHTING FIXTURE - Cl-G. MOUNTED EMERGENCY BATTERY EXIT LIGHTING FIXTURE UNIT EMERGENCY BATTERY UNIT LIGHTING FIXTURE - WALL MOUNTED N SINGLE POLE TOGGLE SWITCH - MOUNTED 42' AFF TO CENTERLINE UNLESS ❑THERWISE NOTED (3) 3 WAY DUPLEX RECEPTACLE - MOUNTED 18' AFF TO CENTERLINE UNLESS NOTED ❑THERWISE <GFI) GROUND FAULT INTERRUPTING <REF) REFRIGERATOR <WP) WEATHERPROOF DOUBLE DUPLEX RECEPTACLE - MOUNTED 18' AFF TO CENTERLINE UNLESS NOTED ❑THERWISE DUPLEX RECEPTACLE - MOUNTED 6' ABOVE COUNTER BACKSPLASH UNLESS NOTED OTHERWISE D COMMUNICATIONS OUTLET - MOUNTED 18' AFF TO C. L. U. N. O, TYPICAL - STUB 3/4' CONDUIT TO TELEPHONE BOARD. PROVIDE 2 GANG BOX WITH ONE GANG RING <TYPICAL). PROVIDE CEILING J-BOX AND CONNECT TO AND INSTALL POWER/DATA/COMMUNICATIONS POLE SUPPLIED BY FURNITURE MANUFACTURER. CONTRACTOR SHALL VERIFY AND COORDINATE EXACT LOCATION WITH OWNER'S FURNITURE PARTITIONS IN FIELD AND MAKE FINAL CONNECTIONS TO OWNERS' EQUIPMENT AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. PROVIDE FLEX LENGTHS AS NECESSARY FOR FINAL CONNECTIONS. BPIQQ SPECIAL OUTLET FOR MODULAR FURNITURE - MOUNTED 18' AFF UNLESS OTHERWISE NOTED. NOTED. CONTRACTOR SHALL VERIFY AND COORDINATE EXACT LOCATION WITH OWNER'S FURNITURE PARTITIONS IN FIELD AND MAKE FINAL CONNECTIONS TO OWNERS' EQUIPMENT AS REQUIRED FOR A COMPLETE AND OPERABLE SYSTEM. PROVIDE FLEX LENGTHS AS NECESSARY FOR FINAL CONNECTIONS. MOTOR DISCONNECT SWITCH OJ JUNCTION BOX 0 TERMINAL CABINET ELECTRICAL PANEL A INDICATES DESIGNATION 1 (D SEE NOTE SYMBOL �\ SOLID LINE INDICATES EQUIPMENT ON COMMON CIRCUIT AND/OR CONTROLLED BY COMMON SWITCH. EACH CIRCUIT SHALL CONSIST OF A PHASE CONDUCTOR, NEUTRAL AND GROUND CONDUCTOR. ELECTRICAL CONTRACTOR SHALL PROVIDE NECESSARY SWITCH LEGS IN CONDUIT TO ACHIEVE SWITCHING IN➢ICATE➢ ON PLANS. ELECTRICAL CONTRACTOR MAY COMBINE CIRCUITS INT❑ A COMMON HOMERUN CONSISTING OF A COMMON NEUTRAL AND GROUND CONDUCTOR AND THREE <3) PHASE CONDUCTORS (A,B, AND C PHASE). DOTTED LINE INDICATES EQUIPMENT ON A COMMON CIRCUIT BUT NOT CONTROLLED ON SAME SWITCH DEVICE. THE FOLLOWING ABBREVIATION NEXT TO A SYMBOL INDICATES, E EXISTING ER EXISTING TO BE REMOVED EL EXISTING TO BE RELOCATED EP EXISTING TO BE REPLACED RE/CKT REUSE EXISTING CIRCUIT RAI REMAIN AS IS NOTE, NOT ALL SYMBOLS MAY BE USED. ELECTRICAL KEYED NOTES: 1. PROVIDE 30A/2P FUSIBLE DISCONNECT SWITCH AT UNIT (NEMA 1) WITH DE FUSES SIZED PER EQUIPMENT MANUFACTURES RECOMMENDATIONS. BRANCH WIRING SHALL BE 2#12, 1#12 GND.-1/2"C. 2. PROVIDE 6OA/2P FUSIBLE DISCONNECT SWITCH AT UNIT (NEMA 1) WITH DE FUSES SIZED PER EQUIPMENT MANUFACTURES RECOMMENDATIONS. BRANCH WIRING SHALL BE 2#6, 1#10 GND. -1"C. 3. PROVIDE 6OA/2P FUSIBLE DISCONNECT SWITCH AT UNIT (NEMA 3R) WITH DE FUSES SIZED PER EQUIPMENT MANUFACTURES RECOMMENDATIONS. BRANCH WIRING SHALL BE (60A/2P), 2#6, 1#10 GND. -1"C. PROVIDE WATER PROOF, GFI SERVICE RECEPTICAL AS INDICATED ON PLANS. DOGK Iq FIRE ALARM DIALER IS FOR SPRINKLER SYSTEM MONITORING. FIRE ALARM SYSTEM SHALL BE INSTALLED PER ALL LOCAL CODES. SD SMOKE DETECTOR, NOTIFIER #SDX-551 ❑FS FLOW SWITCH [] TAMPER SWITCH WG WATER GONG F.A.C.P-FIRE ALARM CONTROL PANEL, NOTIFIER #SFP-2404 FIRE ALARM RISER NTS IRRIGATION TIMECLOCK GF1 GFI A-25 ',A-27 ■ I I I I I I I I I I I I I I I I I III I I ® I I I I I ■ I I I I I I I WAREHOU5E ■ I I5 II I I I I I I ' 4 `AA, - - - - - -- - - - - -- - - - - -- //,F - - --- - - - 'E' I I ■ I I I I I 5UPPLIE5 FILE CABINETS I I5 I I I I I 103 I AH ■ � A-2,� O A A-13. 15 ■ZI MEN A-31 115 ® 0 B-18, 20 OPEN OFFICE AREA OFFIGE O 8-17 I 04 WAREHOUSE B-1 I WOMEN I "I ■ PA55ASE F.E. 3 T ILET f'-L OFFICE OFFICE A-23 II Lh B-35 ROOM 108 1O"1 ' A-29 a IOq ^^ 5UPPLIE5 B-1I B-9 e s ■ ■ _ I I I 400 AMP 240/1PH METER 400 AMPIDISCONNEDT I ELECT, F.E. III I C )l) MY 2 A-1, 3 A-5, 7 O m FLOOR NORTH SCALE: 1/8"=1' -0" GFI ■�■��YYY99UI��2 ■ ■��IT I I I I I I B-5 aFFICE 10b B-7 1 PLAN - POWER AND 1-1/2 HP IRRIGATION WELL VIA TIMECLOCK APPROX 50 FT 3/4" A-33, 35 F.E RECEPTION 102 B-22. 24 OFFICE 105 ENTRY 101 I SIGN J A-21 2" FROM TBB TO PHONE CO. APROX. 150 FT i 3/4" FROM FACP TO BACKFLOW PREV APROX. 150 FT i 'l n TS lcac uum ALL PROPOSED WOR HM,11< ANY CORRECTIONS K REQUIRED C"�'FE10 INSPECT 01S THAT MAY BE NECESSARY IN ORDER TO COMPLY WITH ALL ARELI AE'. ? CODES. REVISIONS: O I.ca L` GV c* 9 "d O p 0 ,3 C� CO H 60 c0 0 a C+J m � � O .d U A � f-I � n\ O � O CD CD \� t1 \ � U ■r O • � ai V CID rr� W O cq cq 4--) O U b 0 N rl 0 Q U U z m a 0 U� co � Ct� G4 w n I V MnZ N G a N rI o O u�F o'a W 4 �000 W _ M H ZIV n z� gn� r�� N o <Wi V IL �w� VJ Z z UDO W PROXOT NO. 10504 I� DATE: MARCH D, 2004 V SHE: E-1 3_ �2-d6r LIGHTING FIXTURE SCHEDULE MARK LAMP DATA DESCRIPTION FIXTURE MODEL NUMBER MOUNT VOLT NOTES' M1 QTY TYPE MANUFACTURER CATALOG NUMBER A2 2 F32-TB 2'X4' RECESS FLUOR ACRYLIC LITHONIA 2GT8-2-32-A12125-120-GLR REC GRID 120 A3 3 F32-T8 2'X4' RECESS FLUOR ACRYLIC LITHONIA 2GT8-3-32-A12125-120-OLR REC GRID 120 C 2 F34CW T8 4' FLUORESCENT INDUSTRIAL LITHONIA EJ-2-32-120-HC CHAIN 120 D 1 32TRT FLUORESCENT - DOWNLIGHT LITHONIA LGFV-32TRT-7SB-T73-120 SURF 120 5 F 1 100 M CUTOFF WALL MOUNTED MINI AREA LITHONIA TWAC-IOOM-120 WALL 120 1 L ] 400W MH LOW BAY WIDE DISTRIBUTION LITHONIA TXS-400M-A30-208 HOOK 240 W 1 250 MV WALL MOUNTED FLOOD LITHONIA TWH-250H-208 WALL 240 X INC INC UNIVERSAL LED EMERGENCY EXIT LITHONIA LOMSW3REL UNIVERSAL 120 2,3 BU INC INC EMERGENCY BATTERY UNIT LITHONIA 6ELM2 UNIVERSAL 120 2, 3,4 LIGHTING FIXTURE NOTES: 1. GENERAL SCHEDULE NOTES (APPLIES TO ALL FIXTURES): A) CONTRACTOR SHALL CORRDINATE FIXTURE MOUNTING WITH ARCHITECTURAL REFLECTED CEILING PLAN(S) AND SHALL PROVIDE FIXTUREMOUNTING AS REQUIRED TO MATCH CEILING TYPE. B) ALL FIXTURES BALLASTS SHALL BE HIGH POWER FACTOR TYPE. C) ALL FLUORESCENT BALLASTS SHALL BE ENERGY SAVING TYPE. D) ALL ELECTRICAL FIXTURES MUST BE INDEPENDENTLY SUPPORTED OF CEILING GRID. 2. FIXTURES TO BE PROVIDED WITH INTEGRAL EMERGENCY BATTERY BACK-UP. 3. FIXTURES SHALL BE CONNECTED TO CONSTANT NORMAL ROOMLIGHTING BRANCH CIRCUIT OF AREA SERVED (l,e, LOAD SIDE OF BREAKER, LINE SIDE OF ANY SWITCHING/CONTROLLING DEVICES). 4. FIXTURE TO BE WALL MOUNTED 7'-6" AFF TO TOP. 5. FIXTURE SHALL BE UL LISTED FOR WET LOCATIONS. m FLOOR NORTH SCALE: 1/8"=1' -O" PLAN THESE PLANS AN0 AL! MIOPOSED WORK 1 ARE SUBJECT TO ANY CORIECIONS 6 REQUIRED E`(INSPECT ORS' THAT MAY BE N=ZAR! 0 ORDER TO LIGHTING COMPLY WITH A:. P i4 >m LE CODES. REVISIONS: jA5-18-04 BLDG l DEPT COMMENTS O L�J N CV C" O O 3 m � eo cc 1 U m IRV FA R1 �j i'4 U � ~ ✓~ Cq 00 CV m 4.4 � O v V 4-4 �V O C \� rrN W c 1� U ° ol O c°i m a O ' 00 � � O 4.; 00 a, U fs n Q O Y N LD r4 O"� O K X 0 1 I z iiYYi Z 7 n O 4 WJ coo Wc oo M F Z 1 U Z=n� gnu N U Y/ } W o Z a. U O O WPROJECT NO. 10504 I� DATE: MARCH 6, 2004 V SHEET: E-2 �e- 4'X8' PLYWOOD TELEPHONE BOARD #6 CU GND TO NEAREST BLDG GND. 2-3" CONDUIT, COORDINATE ROUTING WITH LOCAL TELEPHONE COMPANY TELEPHONE RISER (TYP TELEPHONE COORI.NNATION NOTE: CONTRACTOR SHALL CONTA�.T TELEPHONE COMPANY PERSONNEL AS NECESSARY FOR NEW SERVICES COORDINATION. CONTRACTOR SHALL ❑BTAIN TELEPHONE CO. REQUIREMENTS AND BE RESPONSIBLE FOR ALL WORK NECESSARY TO INSTALL NEW TELEPHONE SERVICES. CONTRACTOR SHALL COORDINATE COMPLETE LAYOUT AND LOCATIONS OF TELEPHONE COMPANY SERVICE PEDESTALS WITH LOCAL TELEPHONE COMPANY AS NECESSARY FOR A COMPLETE 1,ND OPERABLE SYSTEM. CONTRACTOR SHALL PROVIDE ALL INFORMATION REQUIRED BY 'HE TELEPHONE COMPANY, INCLUDING ADDRESSES) AND LEGAL DESCRIPTIONS, FOR THE TELEPHONE COMPANY'S EASEMENT PROCUREMENT NEEDS. TELEPHONE PEDESTAL LOCATION'S AND QUANTITIES AS DETERMINED BY LOCAL TELEPHONE COMPANY. CONTRACTOR SHALL VERIFY AND COORDINATE EXACT LOCATIONS AND QUANTITIES OF ALL SERVICE PEDESTALS WITH LOCAL TELEPHONE COMPANY PRIOR TO INSTALLATION OF TELEPHONE SERVICE CONDUCTORS. ELECTRICAL SPECIFICATIONS 1. DRAWINGS ARE DIAGRAMMATIC AND SHALL NOT BE SCALED. REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR A COMPLETE AND ACCEPTABLE WORKING INSTALLATION. 2. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL CODE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES HAVING JURISDICTION. 3. MINIMUM WIRE SIZE SHALL BE #12 AWG. UNLESS OTHERWISE NOTED ALL CONDUCTORS SHALL BE COPPER WITH THWN OR THHN INSULATION. 4. ALL MATERIAL SHALL BE NEW AND BEAR THE UNDERWRITES LABEL (U. L. ) WHERE APPLICABLE. 5. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY GROUNDED AS REQUIRED IN ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. 6. THE ELECTRICAL, TELEPHONE, AND CABLE TELEVISION INSTALLATIONS SHALL MEET ALL REQUIREMENTS BY THE LOCAL UTILITY COMPANIES. 7, ALL DISCONNECT SWITCHES SHALL BE RATED FOR 100,000 A.I.C. UNLESS OTHERWISE NOTED. ALL FUSES SHALL BE RATED FOR 200,000 A. I . C. AND SHALL BE CURRENT LIMITING. 8, ALL ELECTRICAL SWITCHGEAR SHALL BE BY SQUARE D, ITE, GE, OR CHALLENGER. SUBSTITUTES MUST BE APPROVED BY THE ENGINEER. 9. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS. PLASTIC BOXES MAY BE USED IN LIEU OF THE STEEL BOX WHERE PERMITTED BY LOCAL CODES. IN DAMP OR WET LOCATIONS BOXES SHALL BE MADE FROM CAST ALLOY WITH THREADED HUBS. SPECIAL ENCLOSURES ARE REQUIRED FOR OTHER CLASSIFIED AREAS. 10. SEPARATE WIRE AND CONDUIT SYSTEM MAY BE SUBSTITUTED WITH FACTORY FABRICATED ASSEMBLY OF INSULATED CONDUCTORS IN A FLEXIBLE METALLIC ENCLOSURE WHERE PERMITTED BY LOCAL CODES. 11. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC WITH OVERLOAD RELAYS IN EACH HOT LEG. IT SHALL BE THE ELECTRICAL CONTRACTOR TO PROVIDE ALL STARTERS WHERE REQUIRED. 12. FURNISH AND INSTALL DISCONNECT SWITCHES, OVER CURRENT PROTECTION, AND WIRING FOR THE AIR CONDITIONING SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS ARE TO BE SUPPLIED BY THE AIR CONDITIONING CONTRACTOR AND CONNECTED BY THE ELECTRICAL CONTRACTOR. 13. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTED BY THE ENGINEER OR ARCHITECT. 14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION.. 15. THE ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) ONE YEAR FROM THE DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. 16. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OR PROPERTY DAMAGE FOR THE DURATION OF THE WORK. 400A 240/1PH - ( 3) - 350 MCM CU. IN 3-1/2"C OMETER SOCKET AND METER PN PNL AB•. (3)-500 MCM CU. 4000A 100A IN 3-1/2"C NEMA 1 NEMA 1 400 A 100A DISC 3P W/400A "DE"FUSES 1-#3/0-CU GND TO ( 3) -#3 CU, 5/8" X 8' CU CLAD NEMA 3R 1*8 GND-1-1/4"C ROD, C.W.P. -:F: (3)-500 MCM CU, (3)-500 MCM CU, 1#3 GND-3-1/2"C 1#3 GND-3-1/2"C L TO PANEL "A" IN MECH ROOM POWE2 RISER DIAGRAM NOTE ALL WIRING SHALL BE COPPER TYPE "THW" UNLESS NOTED OTHERWISE . NOTE: SYSTEM TO PROVIDE A U.L. SERIES RATING OF 22,000 A.I.C. PANEL 'A' VOLTAGE: 240 12OV, 1PH, 3W BUS RATING: 400 AMP MAINS: NONE MOUNTING: SEE PLANS A. I. C. RATING 22.000 LOAD SERVED LOADS (WATTS) CKT BRKR C N K 0 T . PHASE C N K 0 T CKT BRKR LOADS (WATTS) LOAD SERVED LTS RECPT MOTOR HEAT AMP A B AMP LTS RECPT MOTOR HEAT CU-1 (3750] 3750 50/2 --- 1 3 + - - * 2 4 60/2 ---- 850 B50 4800 4800 AH-1 -- CU-2 ---- (3750 3750 60/2 ---- 5 7 + - - r 6 8 60/2 ---- 650 B50 4800 4800 AH-2 SERVICE RECPT PHONES 360 380 20/1 20 1 9 11 + - - + 10 12 20/2 - 937 937 EXT LTS - EWH --- 2250 2250 25/2 -- 13 15 * - - * 14 16 20/2 - 1385 1365 LOW BAY LTS -- PANEL 08" 3200 2800 7000 5928 0 0 0 0 100/2 - 17 19 + - - r 18 20 20/2 -- 1365 1365 LOW BAY LTS -- SIGN - SITE EWC 1200 800 20/1 20/1. 21 23 r - - + 22 24 20/2 -- 1365 1385 LOW BAY LTS -- DOCK RECPT DOCK RECPT 1080 1080 20/1 20/1 25 27 + - - r 28 28 20/1 20/1 250 350 SOFFIT LTS WAREHOUSE EMER LTS WAREHOUSE RECPT WAREHOUSE RECPT 1080 1080 20/1 20/1 29 31 + - - * 30 32 20/1 20/1 IRRIGATION PUMP ---- 1200 1200 20/2 -- 33 35 + - - + 34 36 20/1 20/1 FRCP 360 20/1 20/1 37 39 r - - + 38 40 20/1 20/1 41 + 1 1-142 LTS 7200 RECPT 19128 MOTORS 2400 HEAT 4500 SUB TOTALS LTS 10664 RECPT 0 MOTOR 2600 HEAT 19200 PHASE LOADING LTS I RECPT MOTORS 17.91 19.11 5.0 1.251 14.81 1.00 NOTES: 22.31 14.61 5.0 "H" INDICATES HACR RATED BREAKER. [ ] INDICATES NON -CONCURRENT A/C LOAD. SIZES BASED ON LARGEST LOAD. HEAT LTS RECPT MOTORSI HEAT 23.7 CONNECTED KW TOTALS PHASE A 9582 9880 2500 11850 1.00 DEMAND PHASE B 8182 9248 2500 11850 23.7 ADJUSTED KW TOTALS 65.7 TOTAL CONNECTED KW PHASE TOTALS A 33912 B 31780 65.6 TOTAL ADJUSTED KW 240 SINGLE PHASE VOLTAGE 05/18/04 :DATE JOB NAME: 08: 53 AM :TIME COLEMAN 273 TOTAL PANEL AMPERAGE: PANEL "B" VOLTAGE: 240 12OV, IPH, 3W BUS RATING: 100 AMP MAINS: NONE MOUNTING: SEE PLANS A. I . C. RATING 22,000 LOAD SERVED LOADS (WATTS) CKT BRKR C N4PHASE K 0K T . C N 0 T . CKT BRKR LOADS (WATTS) LOAD SERVED LTS RECPT MOTOR HEAT AMP AMP LTS RECPT MOTOR HEAT RECPT RECPT 1080 1008 20/1 20 1 1 3 2 4 20/1 20 1 I600 1800 LTS LTS RECPT RECPT 1080 1080 20/1 20/1 5 7 - *1 8 81 20/1 20/1 1800 1200 LTS LTS RECPT REFRIG 1080 800 20/1 20/11 9 11 + - - + 10 12 20/1 20/1 COFFEE RECPT 800 1080 20/1 20/1 13 15.- + - + 14 18 20/1 20/1 EWC Boo 20/1 20/1 17 19 + - - + 18 20 20/1 20/1 1080 1080 MOD FURN MOD FURN - 20/1 20/1 21 23 - - + 22 24 20/1 20/1 1080 1080 THE Lm A' 11 PROPOSED WOR &wNn g , LTS 0 RECPT 8608 MOTORS 0 HEAT 0 SUB TOTALS LTS 6000 RECPT 4320 MOTOR o HEA IIRED BY FIELD INSPECTORS THAT MAY BE NECESSARY IN ORDER TO PHASE LOADING LTS RECPT MOTORS 6.0 12.9 0.0 1.25 11. 5 1.00 NOTES: .51 11.5 0.0 "H" INDICATES HACR RATED BREAKER. [ ] INDICATES NON -CONCURRENT A/C LOAD. SIZES BASED ON LARGEST LOAD. HEAT LTS RECPT MOTORS HEAT 0.0 CON PHASE A 3200 7000 0 0 1.00 DEMAND PHASE B 2800 5928 0 0 0.0 ADJUSTED KW TOTALS A B PHASE TOTALS 10200 8728 03/09/04 :DATE JOB NAME: 09: 13 AM :TIME COLEMAN 18.9 TOTAL CONNECTED KW 19.0 TOTAL ADJUSTED KW 240 SINGLE PHASE VOLTAGE 79 TOTAL PANEL AMPERAGE: REVISIONS: 5-18-04 BLDG DEPT COMMENTS O ►fJ L` GV mr W 'L1 O O m � o � 4­4 U O � 'ti as •r+ .-J DC Q� .� OS OV \ :. O 00 1 pn O O v 4.) w V O S O O � U O d Z m z p: 0 � 0 mIn mQ � U f�, grn' w h J rz V n '^n z a� a02 ovr x0 '\ F a v x 0 a W _0c0 W0 V• M F- Z r U z n utoi; ir ir v G W Z PROJECT NO. 10504 W I� DATE: MARCH 8, 2004 �•J SHEET: E-3 UA:56-�;,�� � a I GENERAL NOTES 1.1 Fabrication shall be In accordance with USA's standard practices in compliance with the applicable sections, relating to design requirements and allowable atreasea of the latest edition of the "AWS Structural Welding Code DI.r. US.A.'s manufacturing procedures have been certified by: Reference Certification numbers SB.C.C.I. 5011 I.CB.O. FA-321 MIAMI-DADE COUNTY 01058 Houston USA "I35 Indiana (For Beam and Column) 299512 Indiana (For Rigid Frame) 299513 Indiana (For Straight Column) 2SZ510 A.IS.G. Certification For Metal Buildings Member MBMA 12 MATERIALS A5TM DESIGNATION MINIMUM YIELD ( U. N, ) Wide Flange Shapes165 Lbs,'Ft. A36 FY . 36 KSI Wide Flange Shapes K65 Lbs./Ft. A512 or A992 FY . 50 KSI Other Rolled MITI Shapes A36 FY . 36 KSI Structural Steel Plate (Webs/Connections) A10I1, Ae35, A635 FY . 55 KSI Structural Steel Plate (Flanges) A529 OR A512 PY s 55 KSI Cold Formed Light Gage Shapes 410116S FY - 55 KSI Cable Bracing A415-18 Extra High Strength Rod Bracing A36 FY . 36 KSI Roof and Wall Sheeting A192 FY . 90, 8O KSI Machine Bolts A301 FY . 36 KSI High Strength Sets (1/2"o to ro) A325-N FU - 120 KSI High Strenggth Bolts (1 1/8"0 to 1 1/2110) A325-N FU . 105 KSI Anchor Bofte (if supplied) A36 FY . 36 KSI PI a A53, GRADE B FY . 35 KSI HS.S. TUBE A500, GRADE B FY . 46 KSI 13 PRIME Shop primer paint is a rust Inhibitive primer which meets the and performance of Federal Specification TT-P-6640 and Is USA'a Red Oxide color. This paint Is not Intended for long term exposure to the elements. U.5.4. Is not responsible for any deterioration or the shop primer paint as a result of improper handling and/or storage. U.SA shall not be responsible for any field applied Point and/or coatings. (Section 6.5 AISC Code of Standard Practice, lath Edition) IA GALVANIZED OR SPECIAL COATINGS: See Contract Documents and ref. note on the top right hand of this page. 1.5 ALL BOLTS ARE 1/2"0 x 0'-I" A301 EXCEPT: a) Eave strut connection - 1/2110 x 0'-1 1/4" A301 b) Endwall rafter splice - 5/8"0 x 0'-1 3/4" A325-1,1 c) Endwall column to rafter connection - 1/2"0 x 0'-I 1/4" A325-N d) Main frame connections - SEE CROSS SECTION NOTE: Washers are not supplied unless noted otherwise on drawing ib A325 BOLT TIGHTENING REQUIREMENTS All high strength bolts are A325-N unless specifically noted otherwise. Structural bolts shall be tightened by the turn -of -the -nut method in accordance with the lath Edition AISC "specification For Structural Joints Using 45TM A325 or A490 Bolts". A325-N bolts are supplied without washers unless otherwise noted cn the drawings. All bolted connections unless noted are designed as bearing type connections with bolt threads not excluded from the shear plane. I.1 CLOSURE STRIPS ARE FURNISHED FOR APPLICATION: INSIDE- Under roof panels at save OUTSIDE - Between andwall panels and rake trim - Under continuous ridge vent skirts 1.8 ERECTION NOTE: All bracing, strapping, s bridging shown and provided by USA. for this building is required and shall be Installed by the erector as a permanent part of the structure. If additional bracing is required For stability during erection, It &hail be the erector's responsibility to determine the amount of such bracing and to procure and Install as needed. 1.9 ERECTION AND UNLOADING NOT BY USA 1.10 SHORTAGES Any claims or shortages by buyer must be made to U.SA. within five (5) working days after dslivery, or such claims will be considered to have been waivad by the customer and disallowed. 1.11 CORRECTIONS OF ERRORS AND REPAIRS (MBMA 6.10) Claims for correction of alleged misfits will Iva disallowed unless U.S.A. shall haverecafved prior notice thereof and allowed reasonable Inspection of such mleFitp. The correction of minor misfits by the use of drift pine to draw the components into line, mcderats Amounts of reaming, chipping and cutting, and the replacement of minor shortages of materlaI are a normal part of erection and are not subject to claim. No part of the Building may be returned for alleged misfits without the prior approval of U.5A 1.12 ERECTOR NOTE Enact steel with piece marks corresponding to location of piece marks on erection drawings. Erect and plumb bays progressively to insure overall width and length to maintained. 1.13 ACCESSORIES Accessories are not wind rated. 1.14 ROOF SYSTEMS The performance of roof systems supplied by USA Is dependent on correct and proper arectlon and roof system installation by qualified roofing Installers. USA Is not responsible for non-performance due to Improper pr defective insta ilatlon. USA does not certify erectors or roofing Installers. 2S 03/11/04 28 2/3/04 2'1 2/2/04 2ro 5/22/03 25 11/4/02 ALL FLAT FACED PANELS HAVE A TENDENCY TO OIL CAN. USING HEAVIER GUAGES, NARROWER WIDTHS, EMBOSSING OR STIFFENER BEADS (WHEN AVAILABLE) CAN REDUCE OIL CANNING. UNDER NO CIRCUMSTANCES 15 OIL GAN ING CAUSE FOR REJECTION OMNI 111 V, A I .... I ... 1511koi W� DRAWING PACKAGE QUALIFICATION OF HOT -DIP GALVANIZING PROCESS USED ON PRIMARY AND SECONDARY STEEL The Abli(ty of a galvanized coating to meet Its primary objective of providing corrosion protection should be the chief criteria In evaluating Its overall appearance. Zinc coatings produced by the hot -dip ggalvanizing process are excellent corrosion -protection systems. When the coating becomes very thick or dull grey, the coating may not be applicable for architectural purposes. Differences In the luster and color of galvanized coatings and the presence or absence of spangle has no affect on the coating performance. The well-known spangle effect found on galvanizing Is simply a factor of primary crystallization. It is ohlerly dependent upon the zinc bath chemistry, the rate of cooling, the method of pickling, the steel Chemistry, and the thickness of the coating. Additlona ily, handling techniques for galvanizing may require the use of chain slings, wire or other holding devices to Immerse material into the galvanizing kettle. These handling devices may leave a mark on the galvanized Item. These marks are not necessarlly detrimental to the coating. The galvanizing process is for corrosion protection. Inconsistencies in finish and handling marks are not cause for rejection of the product. Nw1mv JOB # 30837 BUYER : KNS CONSTRUCTION END USE CUSTOMER : COLEI" iAN FLOOR CO. BUYER ORDER # : JOBSITE FT PIERCE,FL COUNTY : ST. LUCIE BASIC BUILDING BC1 110'- 8 x 134'- 8 x 22'-0 1/2.12 THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE WITH THE FOLLOWING AS INDICATED: *CODE LOADS ❑ USA Standard (MBMA) Code Edition ■ LL 20 PSF ■ With Trlbutary Area Reductior ❑ SBC ❑ IBC ❑ Ground Snow Load Is = ❑ USG ❑ BOGA ❑ ASCE ❑ Roof Snow Load ❑ MBMA 96 For Wind Loads ■ Wind 140 MPH Iw = 1.0 PER ICBO ER 4015 ■ Collateral 3 PSF EXPOSURE ■ B ❑ C. ❑ D ❑ Crane Cap (Tons) Type ■ OTHER FSC 2001 ❑ Seismic Data: Zone= Aa= Av= Z le: Ss= 51= Group Design Category__ ❑ MEZZANINE: LL PSF DL PSF ANAN ALMUGGHR'-ABI ElOTHER /> ;� Code of Latest Issue to be Used Unless Otherwise Noted. LIC. NO. For buildings with cranes: See Cross Sections and/or calculations for loading EXP COVERING s TRIM AS INDICATED ■ 26GA ■ USA "PBR" ❑ White ❑ UL90-Conets -Fasteners: ❑ 014 x I" STS Member s Stitch ❑ 24GA ❑ ■ Aluminum Zinc ❑ Northern Roof ❑ -12 x IA" 505 Member Cnly W/ 5T5 Stitch ROOF ❑ 24GA USA "Guardian I" 55R ❑ Silicone Poly Unlcote 2000 ❑ wide Mastic ■ 412 x 14" 505 Member with Laptak Stitch ALLOWABLE DEFLECTIONS: ❑ 24GA USA "Guardian 11" SSR ❑ Kynar Unlcote 3000 a1112! Cl Fixed ■ Long Life Fasteners ❑ Color ❑Low ❑Floating ❑ Stainless Steel Fasteners Special Requirements CANOPY(24 GA(MBCI LOK-SEAM/18"/CGREEN) ❑ Nigh ❑ Articulating Thermal Blocks: Oay u 13159h ■ U.SA.MIBMA STANDARDS ❑ Kynar Unlcote 3000 ■ 26GA ■USA "PHA" ❑ ■ Silicon Poly Unlcote 2000 Fasteners! ❑ 014 x I" 9T8 Members 9!Ilch WALL ❑ 24GA ❑ USA "PER" Color L.STONE ■ Long Life Fasteners ❑ N2 x IV 6D5 Member Only W/ STS Stitch Special Requirements ❑ Stainless Steel Fasteners ■ 012 x ly" SD$ Member with Laptak Stitch ■ Standard W/Gutters s Downspout ❑ Simple Eave Trim ❑ Sculptured Eave Trim ❑ Sass, Trim ■ MFOI ❑ s 201 ❑ DP01 ❑ Base Closure TRIM Gutter FrQ EN^ownepoutFrRFKNEave Rake ErRKFIJCornerL"STONEJamblHeadl-bMQUEBassTrimL"STONE Special Requirements ■ Silicone Poly Unlcots 20M ❑ Kgrar Unlcote 3000 FASCIA ■ 265A USA O "FBA" R "PBR" ❑ Color-L.-STONE Trim Color PANEL ❑ 245A Special Requirements 'a LARGE CANOPY ENDWALL ❑ 51110one Poly Unlcote 2000 ❑ Kgrar Unlcote 3000 004 SOFFIT ❑ 26GA USA ❑'PBA" ❑ "F"BR" ■ L-12 Color r:r+RFFN Trim Color J p 6 PANEL ■ 24GA Special Requirements 24GA M5CI SMOOTH SIG 300 ❑ Silicone Poly Unlcote 2000 ❑ KUnar Un',A 3 MP` P BACK ❑ 26GA USA ❑'T'EA" ❑'PBR" ❑ Color. Trim Color PANEL ❑ 24GA Special Requirements ❑ Silicone Poly Unicots 2000 ❑ K nar I of 3000 Af2TITION ❑ 26GA USA ❑ PBA ❑ PBR ❑ Color Trim Color PANEL ❑ 24GA LINER ❑ 26GA ❑ 24GA USA ❑ "PEA" ❑ "PER" ❑ Color. Trim Color pecial Requirements ❑ Silicone BUYER/END USE CUSTOMER RIESPON61BILITE6 2.1 It is the responsibility of the BUYER/END USE CUSTOMER to obtain appropriate approvals and secure necessary permits from City, County, State, or Federal Agencies as required, and to advise/release U.SA to fabricate upon receiving such 22 United Structures of America's (hereafter referred to as, USA) standard specifications, apply unless stipulated otherwise in the Contract Documents. U.SA.'s design, fabrication, quality criteria, standards, practice, methods and tolerances shall govern the work with any other Interpretations to the contrary notwithstanding. It Is understood by both Parties that the BUYER/END USE CUSTOMER Is responsible for clarification of Inclusions or exclusions from the architectural plans and/or specifications. 23 In case of discrepancies between USSA's structural steel plans and plans for other trades, U.S.A.'s plans shall govern. (Section. 3 AISC Code of Standard Practices, lath Edition) 2.4 Approval of U.SA. drawings and calculations Indicates that U.SA. has correctly Interpreted and applied the Contract Documents. This approval constitute$ the contractor/owners acceptance of the U.SA's design concepts, assumptions, and loading. (Section 4 AISC Code and MBMA 333) 2.5 Once the BUYER/END USE CUSTOMER has signed USA.'$ Approval Package and the project Is released for fabrication, changes shall be billed to the BUYER/ END USE CUSTOMER Including material, engineering and other costs. An additional fee may be chargedif the project must be moved from the fabrication and shipping schedule. 2.6 The SUYER/END USE CUSTOMER is responsible for overall project coordination, All Interface, compatibility, and design considerations concerning any materials not furnished by U.S.A. and USA.'* steel system are to be considered and coordinated by the BUYER/END USE CUSTOMER Specific design criteria concerning this interface between materials must be furnished before release for Fabrication or U.SA,'* assumptions will govern (Section 4 and Commentary, 415C Code of Standard Practice, lath Edition) 2.1 It le the Ireeponeibllity of the BUYER/END USE CUSTOMER to Insure that USA.'s plans comply with the applicable requirements of any governing building authorities. The supplying of sealed engineering data and drawings for the metal building system does not imply or constitute an agreement that US.A, or its design engineers are acting as the engineer of record or design professional For a construction project. These drawings are sealed only to certify the design of the structural components Furnished by USA 2S The SUYER/END USE CUSTOMER Is responsible for setting of anchor bolts and erection of steel in accordance with U.SA.b "For Construction" drawings only. Temporary supports such as guys, braces, falsework, cribbing or other elements required for the erection operation shall be determined and furnished and Installed by the erector. No Items should be purchased from a preliminary set of drawings, Including anchor bolts. Use only final "FOR CONSTRUCTION DRAWINGS" for this use, (Section 1 AISC Code of Standard Practice, lath Edltlon,) 2.9 United Structures of America Is responsible for the design of the anchor bolt to permit the transfer of forces between the bass plate and the anchor bolt In shear, bearing and tension, but is not responsible for the transfer of Anchor bolt forces to the concrete or the acisquacy of the Anchor bolt In relation to the concrete Unless otherwise provided In the Order Documents, United Structures of America does not design and is not responsible for the design, material and construction of the foundation or Foundation ambedments. The END USE CUSTOMER should assure himself that adequate provisions are made In the foundation design for loads imposed by column reactions of the building, other Imposed loads, and bearing capacity of the soil and other conditions of the building site. It Is recommended that the anchorage and foundation of the building be designed by a Registered Professional Engineer experienced in the design of such structures. (Section A10 MBMA 1986 Low Rise Building systems Manual) 2,10 Normal erection operations Include the corrections of minor misfits by moderate amounts of reaming, chipping, welding or cutting, and the drawing of elements Into line through the use of drift pins. Errors which cannot be corrected by the foregoing means or which require major changes In member configuration are to be reported Immediately to USA. by the BUYER/END USE CUSTOMER, to enable whoever is responsible either to correct the error or to approve the most efficient and economic method of correction to be used by others. (Section -1 AISC Code of Standard Practice, lath Edition) 2.11 FIELD MODIFICATIONS - WARNING Neither the fabricator nor the BUYER/END USE CUSTOMER will cut, drill or otherwise alter his work, or the work of other trades, to accommodate other trades, unless such work Is clearly specified In the contract documents. Whenever such work is specified, the SUYER/END USE CUSTOMER Is responsible for furnishing complete Information as to materials, size, location and number of alterations prior to preparation of shop drawings. (Section 1 AISC Code of Standard Practice, lath Edition) The strength, stability, and safety of this building may be affected by cutting, drilling or removing any components of the building. No such modifications may be made without the written approval of United Structures of America, Inc. Collateral loads or other components provided by others may be supported on this bullding in the designated locations if specifically Included in the design loads. Unless the connections for such components have been designed and detailed by U.S.A. the customer Is responsible to snsure appropriate connection details are utilized. 2.12 WARNING In no case should Aluminized Zinc steel panels be used In conjunction with lead or copper. Both lead and copper have harmful corrosive affects on the Aluminized Zinc alloy coating when they are In contact with Aluminized Zinc steel panels. Even run-off from copper flashing, wiring, or tubing onto Aluminized Zinc should be avoided. 2.13 SAFETY COMMITMENT UNITED STRUCTURES of AMERICA has a commitment to manufacture quality building components that can be safely erected. However, the safety commitment and job site practices of the erector are beyond the control of U.5A It Is strongly recommended that safe working conditions and accident prevention practices Iva the top priority of any job site. Local, State, and Federal safety and health standards should always be followed to help sure worker safety. Make certain all employees know the safest and most productive way of erecting a bullding. Emergency procedures should be known to all employees. Daily meetings highlighting safety procedures are also recommended. The use of hard hats, rubber sole shoes for roof work proper equipment for handling material, and safety nets where applicable, are recommended. Contractors/Erectors should be aware of 05HA regulations for Steel Erection. The following OSHA Regulations (Standards 29 GPI) are applicable to Steel Erection: OSHA Steel Erection Regulations, Part Number 1926, Subpart "R" 2.14 Manufacturer Is not responsible For bodily Injuries or material damages during unloading, handling or storage ❑ Kura uniccte 3000 ** NOTEI Customer To Provide Colors Denoted UIRh* *(If Any) On Returned Dwe'S. 2000 ❑ Kynar Unicots 3000 PI I PERMIT 15/24,04 Job Number: Soo 1 SHEET LI of I u v IU I M I'3'4 14 -6 14 -B Z3 (TYRTHIS BAY Z3 (TYRTHIS BAY F'URLIN LAPS 11-1 1'-1 1'-1 1'-1 1'-1 1'-1 �i ea Cam. Ft, 0 0 0 0 134'-S 0/0 STEEL 21'-6 21'-6 21'-6 21'-6 D5 (TYP) F6 E6 E-T 4 s F- Li ZI Zap ? . 0 S >74 / \\ Z4 // Z5 \ Z6 / ZI Z5 \\ Z6 // Za ZI \\ Z4'/ Z5 \\ 2C4/ Za ZI // Z4 \\ g Z5 // Z6 \\ g Z8 ZI Z4 \ \ Z5. / Z6 \ Za ZI \\ Z4 // Z5 \\ Z6 // Za ZI / \\ # Z5 \\ C9/ Za ZI // Z4 \\ $ Z5 // Z6 \\ S Xa ZI / \ / Z4 \ Z5 / Z6 \ ZB ZI \\\ 14 /// Z5 8 �0 a -m Zl \ \ Z4/ / Z5 \ \ Z6� / Za XI /\ // Z4 \\ 03i \°6 / \3 / Z4 \ Z5 /\ // Z6 \\ ZB ZI Z5 GO�i 7% �! Z6 `. Z8 /I 0 / r, / i 9 I m Z2 \ Z5 / \ / Z4 \ \ Z-1 / / \ / Z9 Z2 \\ Z5 // Z4 \\ Z1 // Z9 Z2 / Z5\ Z4 / Z1\ Z0 Z2 Z5 \& aCi/ \3 / \ Z4 Gm/ Z'1 \ems, N// \ / Z9 Z2 \ Z5 / Z4 \ ZT / Z`J \�J \ \ r Z2 \\ Z5 // Z4 \\ ZT // Z9 Z2 / Z5. / \ Z4 / Z5. Z9 Z5 \ a Z40// ZT \\@� Z9 Z2 m Z2 \ Z5 / Z4 \ Z'i / Z9 9 Q Z2 \\ Z5 // Z4 \\ Z7 // Z9 Z2 / Z5. Z4 / Z1. ZS Z2 / Z5 \ g / \c Z4 j/ Zi \\C Za Z2 b/ \ Z4 �/ ZT \ zi __rl E2 ❑ E4 E4 ❑ E5 5Z2 (RER 5T1) E6 ❑ E& ROOF FRAMING PLAN 9'-ID **PAN]=LS** **TRIM** **ACCESSORIES** ROOF-26GAiP8R)AZINC GUTTER-26G4/E.GREEN MK. QTY. DESCRIPTION WALL-26GA/A/L.5T0NE p0U,45POUT-26GA/E26REEN A 2 10-0 x10-0 FRAMED OPNG.(FOR RUD) CANOPY-24GA/LOK-SEAM/ CORDER-2( GA/LSTONE B 2 10-0 X 12-0 FRAMED OF'NG. (FOR RUD) CJSREEN JAM15/14EAD-26GA/LSTONE CANOPY WALL- 26GA) RAKE-26GA/E.GREEN PBR/L.STONE/E.W.I BA5E-26GA/L.6T0NE SOFFIT-24 GA/LI2/ CGREEN co IDS (TYP) 9'-ID A **MISC, MATERIAL** L � O NOT ct steel with piece marks corresponding to location of piece marks on action drawings. Erect and plumb bays progressively to insure overall nth and length is maintained. SUE REV. DESCRIPTION DATE 'dam DESCRIPTION: ERECTION PLAN PI PERMIT /24 CU5TOMER: KNS CONSTRUCTION USA. III��I LOCATION: FT PIERCE,FL BUYER NOS GOLEMAN FLOOR co. DRAWING BY DATE CHECK BY ATE s UNITED STRUCTURES OF AMERIGA, INC. TW 5/11/04 rou eUecu61 uousroN, TexAs nm99 Jog M OADS DRAWING * ISSUE zai-4 2-e241 3ID831 El OF 6, PI SEE COVER O O _ REF E2 FOR CANOPY ROOF PLAN �J 1 RIDGE SYMM. Q 12 CJ \ \ C6) VO x 2" BOLTS, I C4" CONNECTION fE) ly 4 —— — — — — — — — — — — — — — w J f6) VO x 2" A325 BOLTS U 02" CONNECTION M) (12" SCAB M) Q SOFFIT OUT `fl LINE r U TI FIN. FLOOR IS'-6$ (t CLEAR) 20'-0 O/O STEEL CROSS SECT ION e LINE 8 c SECTION u; a M v COLUMN 325 BOLTS IS UE REv. DE5cRIPTIoN DATE DESCRIPTION: ERECTION PLAN r 11' I PERMIT /24 CUSTOMER: KN8 CONSTRUCTION O gyp^'UOSIV& ����� LOCATION: FT PIERCE,FL Q�CV BUYER NO.: COLEMAN FLOOR C UNITED STRUCTURES OF AMERICA, INC. DRAWING BY DATE CNE h" � TW 5/11/04 wo TM, MXA5110" JOB LOADS DR :5 30531 SEE COVER $Y DATE E3 OF ISSUEAll a D I',I 2ER - 4ER 3ER 2ER ER ER - Z23 223 i Z21 \ \ / Z23 Z23 Z22 Z21 Z22 Z23 Z23 T22 CMU WALL (NOT BY U54) CH \ / (FOR CMU WALL) x \ ni IS'-4 17'-6 19'-6 19'-6 IT'-6 IS'-4 110'-8 O/O STEEL ELEVATION 'a LINE "0a>11 LEFT ENDWALL T 4 r 12 \ CMU WALL CMU WALL (NOT BY U5A) (NOT BY U5A) ri W l� N I I I I NMi N N N lii N = = N IIi In 1{l 1{1 N N IO W In LD N N N_ N N N N_ N_ N_ fn [11 R1 Hi hl In m IV V_ V m �_ m m N N N N_ N_ N N_ N II 10 &HEETING e LINE ",a�" LEFT ENDWALL L10 .2 A B G (bOLDIER GOL. LOG) (SOLDIER GOL LOW I' -I I' -I 2ER SER 6ER 2ER ER ER 223 21 Z22 / Z23 Z23 / / Z21 21 Z22 - - - / \ _ ZZ3 Z23 ' T22 g Z21 F - - \- - - \ .-I.i / ON 6 i w \ II'-10 20'-0 0/0 CANOPY 5TL. 15'-4 110'-S 0/0 STEEL ELEVATION LINT= IIIII fi;;�IG4T I=NDWALL I 12 \ CMU WALL (NOT BY U5A) N I I I I N N N CO IO N In IIl N' W = = N In !II iON LLl IL1 N N i W N' II1 N 10 6l 4EETINC a LINE "I" RIGS 4T ENDWALL 10 i _IN LLS.AJ NOTE. U.S.A. only provides the roof purlin. All other material and hardware Is by others. CLIP ANGLE, BOLTS, HANGER, ETC_ BY OTHERS Acceptable Connection Detail NOTE: Drilling of holes in .flanges of purlins Is structurally detrimental to the. member. Any collateral loads, which are Included in the purlin design loads, are to be attached by connection directly to the web only. Field Modifications - UJarnina Ref.: cover sheet LI paragraph 2.11 PURLIN—�..//.. Field Drill 194ole Eave ®j Struts —_ 0 Frame CL23 SECTION" A" (A6 SHN.) 5ECTION"5" (OPP. HND,) Eave Strut �$I� I�— Strut Purlin / lIP Required) �� I CL23 C-CLAMP ALL -THREAD ROD Frame Flange C-Clamp is not Connection through the (6) l:Iox la' M.B. an acceptable connection flange is not acceptable LOW EAVE STRUT CONNECTION ATTACHMENT OF WITH CL23 STIFFENER PLATE SUSPENDED ITEMS (BY OTHERS) 1► B"<_r Building'Golumo IrY" Building Color Detail "A" Portal Brace �Ba4pacs l PORTAL FRAMING ELEVATION FRAMING ELEVATION First Eave Purlln Strut /9 ai Frame Portal Frame 5 CTION"Bl' Main Frame (2)- W"w NTJB Column 4'-0 O.C. 9 bForts IFrame LEI �J DETAIL" All SECTION "CI' ma (4) Bolts g Strut Purlin (IF Required) Frame (4) B'OLT PURLIN CLIP CONNECTION AT MAIN FRAME A 6,43 BY (Field Attach) Eave Strut Member Screws LOW EAvE STRUT PURLIN CONNECTION (AT DIAPHRAGM) 12" 1211 1211 gI=II 21211 331211 212II 91211 212 II MEMBER SCREW LOCATION Detail (ALL MEMBERS EXCEPT AS NOTED) 1211 12" 1211 2i211 ill 21211 21211 ill 212'1 21211 1 ll 21211 MEMBER SCREW LOCATION Detail MainFame (PEAK PURUN EAVE STRUT AND PANEL END LAPS) Rafter Stitch Screws At ontintious Tape Sealer 20" On Center V'xj�" (Standard) INN, (Optional) Main Frame Column DETAIL "A" Member Screws , Roof Continuous Tape Sealer / as"AN' (Standard) tiur �EQIJ IN112 (optional)lin Be Specified On Order) SECTION THRU PEAK PURLIN ANp PANEL END LAPS NP5R° PANEL ROOF 8" Zee Strut piaphragm(SZU Strut Purlin Member Screws NOTEI W PATTERN5 SHOWN, 5ATI5FY UL-90 REMENTS FOR ROOF, •Flan a Brace WS Col.- F52 W14 COI - FBI WI0 Col.- FBE, WI6 Col.- FBH WI2 Col- F53 WI8 Col: F83 ndwall Girt _fE{Flange Brace (One Side Only) ° of Rolled Endwall Column i-TK-EWB_) � J 0 ro a°li Q0 ai o o Column lu 11 f I End all Girt End Rafter HOT ROLLED ENDU)ALL COLUMN ndwall Girt ° +Flange Brace 1 (One Side Only) of Rolled Corner Column(MK-EW1C_) Field fo v Block COIUmn Girt-,"%xI" Mach. Bolts e NN Endwall Sidewall Girt I steel Lins 2 End Rafter NOT ROLLED CORNER COLUMN Steel Stitch Screw Spacing — To Match Wall Panel 5idelap Spacing. Filler Trim (MK-CT02) Cable Brace Inside Waher lout Washer Eye Boll (2) Y"' x 11 (FIELD DRILL EAR Hex Nut Wsb of trams DOOR CABLE BRACE TO FRAME DETAIL NOTE: Use A Backup Plate Under The Hillside Washer For Cold Form Members. Purlin 5h�tinq g no Rafter ( Ceel or III P) (4) V x 14" 925 Bolts Endwall Column ("Cee" or I� II) Endwall Girt BEARING END FRAME BY -FRAME ENDWALL Wall Panel Masonry Anchors (By Others) Member 5crew — At 12" 04. "'PBa" Pa Corder Trim Masonry Filler Trim 5701124 6'I (MK-CTOU *01 (MK-CT02 OUTSIDE CMER DETAIL "PBA" PANEL 1' TO 12" OFF MODULE) / � Base Channel f/77 ./I / Masonry Wall Panel ley Others) Pop Rivets At OPEN FOR MASONRY Member Screws 1211 On Center (WITH BASE CHANNEL) At 12" On Center Head Trim (MK-DH0;) Header Pop Rivets At Jamb 12" On Center Wall Panel Jamb Trim (MK-DJOU ( "PBA" Panel ) JAMB TO GIRT SECTION 6 JAMB CONNECTION JAMB DETAIL FOR FRAMED OPENINGS Frame Additional �� ERECTOR NC Fing. Bra (If Rsq'd.) (4) Bolts Ref Ref. Goss Section ¢ Of Frame PURUN LAPS (B Bolts. Add 2 additional per fing. bre.) Attach To Eave Strut With Pop Rivets At 3'-0 On Center Inside Closure 4" Member Screws At 6" On Center Stitch Screws At 6" On Carter Roof Pan Panel Cap Trim Member 5crews (MK-ET02) 0) At 12" On Center Gutter (MK-EG__) Eave 5trut Outside Closure d 6lllch Screws At 24" On Center Wall Panel (OPTIONAL) LOW EAVE DETAIL WITH EAvE GUTTER (SHEETED 51DEWALL 1211 11 1211 Roof Steel Lire MEMBER SCREW LOCATION Detail "A" HEADER DETAIL FOR FRAMED OPENINGS StltchScrewsAt12"on Rake Trim Center With Cominuous Tape SHEETING DIRECTIONS (ALL MEMBERS) hK-RTOU Sealant Linder Trim *3 Stitch Screws Equally Spaced Roof Panel T [OR Between Ease Member And T-3i" Girt. Member ecraws Ir Y-T Girt Is Req'd, Than Use One stitch Screws Sheeting Angle Stitch Screw Between Members. At @" on center MTERIOR Stitch Screws Above T-3II" Girt outside closure T Be Equally Spaced. Stitch ScreWS 5titch Screw To Exceed 2'-0" O.C. Wall Panel Purim (sego ld) DETAILIIAII, RAKE DETAIL WITH SNUG INSIDE CORNERS T $ERECTOR NOTE: SHEETED ENDWALL CAUTION: TO INSURE 3'-0 VE . Stitch Screw Spacing OVERTIGHTENING STITCH u. For 'PEA" Panel IS NOT The SCREW WILL CAUSE BUCKLINCs PE34 PANS ALL Same As "PBR" Panel ORAL EMOTES , I. ALL 501 ARE 1/2" DIA. x P MACHINE BOLTS UNLE55 NOTED. 16SUE REV. DESCRIPTION DATE �Q� DESCRIPTION: ERECTION PLAN PI PERMIT /24 1 CUSTOMER: KNS CONSTRUCTION d,6� �05®A� IIIIII LOCATION: FT PIERCE,FL BUYER NO.: COLEMAN FLOOR CO. UNITED STRUCTURES OF AMERICA, INC. DRAWING BY DATE lcwrzcK BY DA7E 512eUswa+o TW 05-1-200 Nousrc^t texas 11035 �Og • LOADS DRAWING • ISSUE xel-au-exam 3(083-i SEE COVER 5TI Of 2 PI 4A1 Pop Rivet Lap 2" -(Typp) Caulk And Pop Rivet r-- ' j Gutter. Downspout strap / TBA" Panel / Field Bend Gutter "Al "PBA" PANEL WALL, Tabs into Downspout -Downspout 1)005FOUT STRAP ATTACHMENT Pop Rivet Gutter Strap (MK-SGOU At 4'-0" On Center For EG01 stitch Screw DOIl`ISPOUT TO GUTTER DETAIL AL 3'-0" G1 Center For EG02 Pop Rivet Gutter Gutter- z Eave Strut Downspout Site MK-D7 ) FeldCut Gutter With X" Pattern U a ll Panel Pop Rivet i � SECTION "A" Girl - SpliCe (if Rod) ' Base Donnel I Downspou (MK-DS__) Masonry Wall (not by U.5,4) Flntsl�d,Floor D.S.Kickout a o, p .' (Install W12 Pop Rivlt6 on 3 Sides) , ; 4 .4 DOWNSPOUT DETAIL AT SHEETED UJALL DS. STRAP QUANTITY AVE HEIGHT QUANTITY 10'-0 2 IT-0 2 14'-0 16' 0 2 —2 20'-0 2 25'-0 3 ,i TYPICAL DETAILS VALLEY . lekSeam" PANEL VALLEY TRIM-T TRIPUE BEAD'-- 1 TAPE SEALER FASTENER N1 E MN 16 GA 4'V O.C. SUPPORT PLATE —a-Vll 9'Us (FASTENER MUST GO 9' Valley l n g, than most 0'-used THROUGH TAPE SEALER) FIXED VALLEY in valleys longer Nan 30-0'. —URETHANE VALLEY TRIM SEALANT - TnIPLE:BEAO'' TAPE SEALER FASTENER N12 — PANEL PANEL 6^ OVERLAP 6 O a FASTENER NIE 6 BEVEL CUT r ANEL a TO MATCH SLOPE (JFVALLEYTRIM. - PURLIN - VALLEY TRIM PPOFTIF PLATEATE P ISOMETRIC VIEW OF VALLEY Valley must be designed to support the panels between the purlins. (ie: Channel, Angle or Plate) NOTES: FIXED VALLEY 1. For valleys longer than 30% use extended "nay trim (see page LS 15). 2. Do not use this detail with the fixed ridge or hip details. 3. Ends of panels should be 4rh' minimum from the vertical leg of valley trim. 4. Install Triple Bead tape sealer continuously under LokSew"I s panel. 5. Attach 6. See Panel panelEnd Sealant lDetaill" th On FaisPagerLS45 to seal pane ends at em valet'. rough tape sealer antler panel. 1 (FIELD CUT TO MATCH 91MR) SMALL 4 LARGE SIZE EAVE GUTTER il-FAE TgAN61TION dip To AND NxIY)NYs ZZ2 R07 BOM) DETAIL IIXII Vachin A301 .— Machine Galt N\ ,\ Girt Web, of Column T TOutside Flange T of Col. �(one) 150 X P l4Q ] Flat -Head A301 5olt Ty ica! Girt @Long Lap Connection Erector Connection Note: U-met you have a by-pass condition where glrts "re a commonconnection, you must !fret use a flat head bolt to attach one girt to the cPp. Roved head bolts cannot the used In this condition, It must be Plot head bolt In order to be flush This will allow the erector to handle one girt to make the final lap. This makes erecticn simpler and s9fer, The remaining Correction Colts need to be vv 6tandard 4301 machine bolts. POP RIVET L FIELD CUT LEG AS 5HOUN TYPICAL DETAILS FIXED RIDGE IMPORTANT NOTE: TEMPORARILY SECURE PANELS 2 AT RIDGE UNTIL -Z^ CLOSURE 5- 21. IS INSTALLED FIXED RIDGE FASTENER#14-//�� FLASH URETHANE SEALANT PANEL M PANEL FASTENER N17 !\ r TAPE SEALER _�1` � -Z^ CLOSURE. C.O.C. CROSS SECTION OF FIXED RIDGE FIXED RIDGE FLASH -- URETHANE SEALANT FASTENER 414 6'O.C. LokSeam^ PANEL / -Z- CLOSURE TRI-BEAD TAPE SEALER ISOMETRIC VIEW OF \ Fns eNER Nn FIXED RIDGE NOTES: 1. Do not use this detail with the fixed save or valley details. 2. peak pudin spacing for fixed ridge Is 5" from the centerline of ridge to web of pudin. If this dimension is riot used, a special ridge flash will be required. 3. The upslupe and of the panel is 3" from the web of the peak pudin. 4. Field cut "Z" closures to lit panel width. 5- Install Tri-Bead tape sealer to panels. Center of tape sealer should he 13W from end of panel. 6. Inslall "Z" closures to peak purliu with Fastener N17 at 6" o c. Vertical leg of'Z' closure should be 2r/"^ from end of panel, 7. Seal end of'Z" closure to panel seam with urethane sealant. S. Attach ridge flash to "Z" closure with Fastener N 14 at 6" o.c. 2'_2 Flan •e Brace 5 Req'd) Additional Flange Brace (if reg'd) APPLY TUBE Ref: Cro56 Section SEALANT TO OUTSIDE < PRIOR TO IN'. RIB COVER "lain Frame Interior Column /// (One) Flathead Bolt Per Connection O L_ J O 0 0 0 0 Sidewa I ' _ Csirt Girt La' As R 'd) Sidewall. Bag, a Dimension iInt Frame Steel Line Bolts FIELD CUT M^ a (One) Flathead Iz"° A30-T Bolt LEGS OF PAh -- OVER EDGE. ADD (2) 12"P 4301 Machine Bolte per Fing. Bre. SEALANT SEAL ENDS < INTERIOR COLUMN INSTALLING F (e Lonci La :?) TYPICAL DETAILS PANEL PANEL CLIP - FACTORY MASTIC ��A ( . 9 INSTALLED PANEL — CROSS SECTION PANEL CLIP PANEL CLIP INSTALLATION FILL FND WITH URETHANE / SEALANT / PANEL END SEALANT DETAIL NOTES: 1. FIN end Of PAMPI seam at OSVS and valleys with urelhane lant. 2. For UL90 raling, UL90 clips with Iwo fasteners must us ii\ ti� ;� DETAIL e TYPICAL DETAILS HIP IMPORTANT NOTE: URETHANE SEALANT /} -.l_-FIXEDRiDGEMIP Y AB' TEMPORARILY SECURE PANELS AT RIDGE UNTIL FASTENER 014A 4' O.C. 7�--, 9` FLASH ,y FACTORY "Z" CLOSURE MASTIC ISINSTALLED Lak9eam' - PANEL = a --- UL90 CLIP '• TRI-READ t ' - TAPE SEALER ' �w//EMI FASTENERNI7 7- CLOSURE 6. O.C. (FILL CUT TO FASTENER NI2 LENGTHANDUEVEL ""N 18 GA. COFFIX E CUT TO FIT PANEL SUPPORT PLATE HIP OF FIXED HIP REV. DESCRIPTION NOTES: 1. Do not use this detail with the Fixed fixed save or valleydetails.p 2, Hip must be designed to support the panels between the Puttee (is: channel, angle or plate). a Bevel cut and Install panels to follow slope of hip. 4. Install Tri-Bead tape sealer to pans Orientals, running parallel to the hip. Center of tape sealer should be 31%" from the center at the hip, 5. Install "Z" closures to panels with Fastener N17 at 6" o.c. Vertical leg of "Z" closure should be 4" from center of hip. UPill� gill, ] -) UNITED 6TRUCTIIRES OF AMERICA, Mt 5d6CWo`xi H TON TEYA611031 291-M3-e341 DESCRIPTION: ERECTION PLAN CU5T0MER: KN5 CONSTRUCTION LOCATION: FT PIERCE,FL BUYER NO.r COLEMAN PLOOR CO. _ DRAWING BY DATE CHECK BY _ TW 5-11-04 JOB " LOADS I DRAWING 3m83T 6EE COVER I ST2 Of 2 "RIGIl`,.IAf_ 115" RIvET5 BOTH SIDES B COVER PI O O I 0 w w N H IV-4 14'-$ EM 0 4 D 2 F 2 2 2 2 F 2 2 2 2 F 134'-8 0/0 STEEL 21'-6 2'-0 10'-0 22 2 O 0 I O 21'-6 21'-C6 2P-6 N N N N E E E E E E E E A D D A A A A A N N O N N V 1 SH FLOOR ELE-=+IOO'-O 0 . D I.OF ALL BASE PLTS. ELE.=+100'-O 42I4z 6 0, ah TYP. O 2 2 1Ft %� N E -j "ClB Q FY B \O G \O. Ln B B B B ., _� O � m N N1 .. 61 N 0 D ao N _4 _2 °'� N �0 V N D m — H W 22 N Q � 0-1 6'-0 O/O STL N D D N AI � a IA IA IA IA A N D� � � N o m ?2 L2 22 22 22 � 4 1'-0 D 21'-6 DL +LL v= a K ANCHOR BOLT SETTING PLAN B G A3 A.I DL + WL J' � v= 9 K O O Q STEEL LINE H= 1 K 5 6 WIND 2 4 2 3 FIN. FLOOR MAX, E.W. COLUMN REACTION AT SEARING FRAME — oa LINES 0.541) WIND_ Cs O " O2K 0.2K 5 K (IF RAMP 'The Anchor BoIV etaile shown on this drawing locate the Anchor Bolts --� ~ ~ a " - CAL - In reference to both the Building Steel Line and the outside of USA.'s K� I.I ¢ SUGGESTED panel recass of iR 1"1 K K Dunited Structures of America Is responsible For the design of the anchor 1 1 I SECT I O1. II e MFOI bolt to permit the transfer of forces between the bass plate and the 4,K 4 K V 1..� 1 V — 19'-4 - I 14'-8 anchor bolt In shear, bearing, and tenelon, but le no! responsible for the DL +LL transfer of anchor bolt forces to the concrete or the adequacy of the K anchor bolt In relation to the concrete. Unless'. otherwise provided In the Order Documents, United Structures off 0.3K 0.3 — BRACED BAY REACTION America does not design and Is not responsible for the design, materiel, SK o4K K (e LINES 0.54'1) and conatruction of the Foundation or foundation smbedmerts. The End 0 5 K 0.1 Use Customer should assure himself that adequate provisions are made In the Foundation design for loads Imposed by column reactions of the building, other imposed loads, and bearing capacity of the soft and AN�G R BOL7 DETAIL SHOWN BELOW 16 BASED ON A other Candidate of the building site. PORTAL FRAME REACTION DL +WLL 5U93E5TED US.A, DESIGN. PLEASE CONTACT YOUR it to recommended that the anchorage and Foundation of the building In be destgnad by a Registered Professional Englnaer experienced n the b (e LINES A.64D) MAIN FRAME REACTIONS � LINES 8 ENGINEER RECORD FOR ANY SPECIAL EMBEDMENT REQUIREMEN75. REF. GENERAL NOTE '2 ON THIS PAGE. design of such structures. (Section A10 MBMA 1986 Low Rise Bulldlng Systems Manuab NOTE: SHEAR AN61-E6 AND/OR ANCHOR QBottom of all Base Plates are at the same elevation. (UNLESS NOTED) TIES ARE NOT FURNISHED BY U,SA. LINE LOADING AXIS H v nZ)LILL t t,,rC>L"wL ALL REACTIONS IN KIPS LOADINCz ANCHOR BOLT DETAIL P-F* SYMBOL DIA. OTY L AXIS H y L T U.S.A.) " UP TO�;1/46TM " OVER� - A36 UT A4 t I/2" 66 A301 W. 45 5/8" 64 P-2" A6 3/4" 56 Al T/8" 24 I -8" A8 I" 2,211 A10 1 1/4" 2 -4" ANCHOR BOLTS (Bl' OTHERS ) Al2 1 1/2" 2'-0. Max. 3'-0 oz.) MASONRY (By Ot era) FIN. FLOOR a. e s.. SECTION 111D11 T I PROJ- I ISSUE I REV. Ab D 0.1 K 0.0, 0.1K 2.0K1 3.5K 20K O DL 3.4 K O.OK 3.4 K 5.2K} 19.4K 6.2K II LL O &.1K O.OK 0.1K �- 15.3K1 l 27.2K 8-1K WLL I 0.1 K O.OK 8.1K S.IKI 212K 153K S.GK O:OK m.SK '32K� 1 13.SK I.9K WLL II 0.5 K O.OK 8.6K 1.9K1 13.SK 9.2K 1 WLR II MAIN FRAME REACTIONS -a LINES 1-6 IN HIM STEEL ONE 4-d1° ANCH40P, BOLTS BASE T PE llf=ll O'-8 MASONRY BTM OF BASE 44"mANCHOR 5OLT5 BASE T�/FE ''Gil �6 2-12"m ANGI-IOR BOLTS SOLDIER COLUMNS BAcaE T1 PE 1lIl DESCRIPTION: ANCHOR BOLT SETTING PLAN 5T / CUSTOMER: KN5 CONSTRUCTION USAlilp IIIIII LOCATION: FT PIERCE,FL BUYER NO.: COLEMAN FLOOR CO, UNITED STRUCTURES OF AMERICA, INC- RAWING BY DATE CHECK BY DATE lea euscHC I 5/11/04 KTL 5/24/04 uoue*w+, tExns nurse JOB " LOADS DRAWING " ISSUE 281- 2-e2+1 30831 SEE "Ll" FI OF 1 1 O 22 8 (MIN.) 4-a"" ANCHOR BOLTS le±AG E T T f= E 11 /4 I I 4-1"0 ANCHOR BOLTS BASE T`f=E 11511 N N \9 �J 0'-10 2 4 �� a4 4-VO ANCHOR BOLTS BASE TiPE 11CII ENDWALL I / /— STEEL LINE O'-10 2„ 812 4-VO ANCHOR BOLTS BASE TYPE 111DII E 'a "r „