HomeMy WebLinkAboutSUBMITTED DOCUMENTS00/03/2004 03:25 4076475234
PAGE 01
-.-.�1465 Gene Street
-.,.-�, Winter park, Florida 32789
f ` CONafRUCrION, 407-647-1234 Fax: 407-647-5234
FAX
Attn: Christine Moore
Company: St. Lucie County
Fax #: 772-462-1735
RE: Coleman Floor Company
Comments:
Permit revision to permit 424041046.
Date: 8/3/04
*of Pages: 1
From: Keith Severns
Billy Crouch was in your office today speaking to you about our revisions on this project.
He says that you are requesting that we give you the amount that it is going to cost to
make those changes.
The total additional cost will be:
1$12,000,00
Please fax us back the additional permit cost so that we may get a. check sent overnight
this afternoon.
s
DATE FILED: 9/ 3 PERMIT #:
REVISION FEE: ,? a( . of RECEIPT #:
ST. LUCIE COUNTY
DEPARTMENT OF COMMUNITY DEVELOPMENT
BUILDING & ZONING
,
2300 VIRGINIA AVENUE
FORT PIERCE, FLORIDA 34982-5652 G,rrjL'
772-462-1553„Sks'�9r
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION
1. LOCA'
L
2. DETAILED DESCRIPTIONS OF PROJECT
REVISIONS: % ,"zwt /[A'/N/ZdGM , A.Zr/--)
3. CONTRACTOR INFORMATION:
ST. OF FL REG/CERT #: C G C Q 44
BUSINESS NAME: iV C
QUALIFIERS NAME: k!, Sy
ADDRESS: / G5 C.G
CITY: 1g. n 1. a.
PHONE (DAYTIME): Yc-'7 -/
4. ARCHIT/ENGINEER:
NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
12119/02
LUCIE COUNTY CERT #:
S T. L U C I E C 0 U N T Y
2300 Virginia Avenue
Ft. Pierce, Florida 34982
Growth Management Division
PAYMENT
R E C E I P T
TRANSACTION NUMBER: 01192997 i TRANSACTION DATE: 03 AUG 2004
PERMIT NUMBER: 24041046 PERMIT TYPE: BUILDING COMMERCIAL
PERMIT JOB DESC: * NEW COMMERCIAL BUILDING /OFFICE & WAREHOUSE
(COLEMAN FLOORING)
JOB ADDR: 7385 COMMERICAL CIR (6534)
PARCEL NUMBER: 1335-802-0045-000/1
FCC DESC: *OTHER NONRESIDENTIAL BUILDINGS
APPLICANT: KEITH SEVERNS
F E E S C O L L E C T E D
FEE CODE DESCRIPTION AMOUNT
-------------------------------------------------------
REVIS REVISION TO PLANS 150.00
AMOUNT PAID: $150.00
FEE WAIVED:
CHECK NBR: 7994
PAID BY: KNS CONSTRUCTION INC
MEMO: CM
8
(328 )
I
ST LUCIE COUNTY FIRE DISTRICT
BUREAU OF FIRE PREVENTION
PLAN REVIEW
2409 Rhode Island Avenue Telephone: 772-462-8306
, FL 34950
FAX: 772-462-8466
Vonstruction
Tenant Improvement
() p ( )Addition ( )Renovation/alterations
( )Shell Only
Jurisdiction:
SLC F.P.B.:
B-04-251
Occupancy:
Coleman Flooring Building Dept:
24041046
Address:
7385 Commercial Cir Number of stories:
1
Contractor
KNS Construction Phone#
407-647-1234
Contractor's Address:
_1465 Gene St City:
Winter Park
State:
FL Zip Code:
32789
ArchitectlEngineer:
The Architecture Co. Phone #
407-332-8299
Building Owner:
Review Date:
6/4/2004
Occupancy Type:
Storage Automatic sprinklers:
Yes
Gross sq ft:
15,120 Net sq ft:
Occupant Load:
Based On:
Construction Type:
SBCCI Type:
IV unp
NOTE
1. All revisions must be in compliance before the final inspection.
2. The Fire Marshal requires 24 hour notice on all inspections.
3. The respective Building Department shall schedule all final inspections through the Fire Marshal's Office.
4. Permit fees are required to be paid in full prior to any inspections.
5. Failed inspections require payment of fee prior to rescheduling of further inspections.
6. A copy of the required revision/s have been transmitted to the Architect () Contractor ( ).
7. Penetrations through rated assemblies shall be of proper UL design. .
8. UL design criteria shall be submitted with the construction plans.
9. Fire Alarm Panels shall be located indoors.
THE FLORIDA FIRE PREVENTION CODE, 2001 EDITION IS CURRENTLY ENFORCED.
REVISIONS REQUIRED
ESS BOX IS REQUIRED ( ) ACCESS KEY SWITCH REQUIRED ( )
A separate permit is required for the installation of the fire sprinkler system.
2. A separate permit is required for the installation of the fire alarm system.
Reviewed by: v¢ir. Date:
6/4/2004
.4
e
t-
Florida Department of Community Affairs
EnergyGauge F1aCom v1.22 FORM 40OA-2001
Whole Building Performance Method for Commercial E
Jurisdiction: FORT PIERCE, ST LU_CIE COUNTY, FL (661100)
Short Dese: COLEMAN Project: COLEMAN FLOOR COMPANY
Owner:
Address: COMMERCIAL CIRCLE
City:
FT. PIERCE
State:
FLORIDA
Zip:
0
Type:
Office (Business)
Class:
New Finished building-
PermitNo: 0
Storeys: 1
---GrossArea: 14903
Net Area: 3227
Max Tonnage: 5 (if different, write in)
Compliance Summary
Component Design Criteria Result
Gross Energy Use 54.11 100.00 PASSES
Other Envelope Requirements - A PASSES
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
PASSES
PASSES
PASSES
PASSES
PASSES
PASSES
Yes/No/NA
IMPORTANT NOTE.- An input report Print -Out from EnergyGauge RaCom of
this design building mast be submitted along with this Compliance Report.
Id
3/13/2004 /
EnergyGauge FlaCom FLCCSB v1.22
4
Q
Y
COMPLIANCE CERTIFICATION:
I hereby certify that the plans and
Review of the plans and specifications covered by this
specifications covered by this calculation are
calculation indicates compliance with the Florida Energy
in compliance with the Florida Energy
Code. Before construction is completed, this building will be
Efficiency Code.
inspected for compliance in accordance with Section
553.908. F.S.
PREPARED BY: DAVIDGAST -
13UILDWGOFFICIAL:
DATE: 2004-0-18
DATE:
I hereby certify that this tiui! i is in complian
with the Florida Energy Eff 'e Icy Cc
1
OWNER AGENT•
DATE:
If required by Florida law, [hereby certify (7 that the system design is in REGISTRATION
compliance with the Florida Energy Code.
No.
ARCHITECT:
ELECTRICAL SYSTEM DESIGNER
LIGHTING SYSTEM DESIGNER:
MECHANICAL SYSTEM DESIGNER:
DAVID GAST FL P.E. 38638
,PLUMBING SYSTEM DESIGNER:
(*).Signature is required where Florida Law requires design to be performed by registered design professionals.
Typed names and registration numbers may be used where all relevant information is contained on signed/sealed
plans.
l
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22 2
,.
Project: COLEMAN
Title: COLEMAN FLOOR COMPANY
Type: Office (Business)
Location: FORT PIERCE, ST LUCIE COUNTY, FL (661100)
(WEA File: DAYTONABEACII.
Whole Building Compliance
Design
Total 54.11
Reference
100.00
ELECTRICITY 54.11
100.00
AREA LIGHTS 23.22
67.34
MISC EQdUIPMT 14.68
14.68
PUMPS & MISC 0.02
0.02
SPACE COOL 8.04
9.80
VENTFANS 8.16
8.16
Credits & Penalties (if any): Modified Points: = 54.11
PASSES
Project: COLEMAN
Title: COLEMAN FLOOR COMPANY
Type: Office (Business)
Location: FORT PIERCE, ST LUCIE COUNTY, FL (661100)
(WEA File: DAYTONABEACH.
Other Envelope Requirements
Item Zone Description
Design Limit Meet Req.
PrOZol Wa4 PrOZol Wall Adjecent to Unconditioned Space - Max Uo 0.13 0.33 Yes
PrOZolRfI PrOZol Exterior Roof - Max Uo Limit 0.05 0.09 Yes
PrOZ02Rfl Pro o2 Exterior Roof - Max Uo Limit 0.05 0.09 Yes
Meets Other Envelope Requirements
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22
External Lighting Compliance
Description Category Allowance Area or Length ELPA CLP
(W/Unit) or No. of Units (W) (w)
(Sgft or it)
None
Project: COLEMAN
Title: COLEMAN FLOOR COMPANY
Type: Office (Business)
Location: FORT PIERCE, ST LUCIE COUNTY, FL (661100)
(WEA File: DAYTONABEACIL
Lighting Controls Compliance
Acronym Ashrae Description
Area
No. of Design Min Compli-
ID
(sq.ft)
Tasks CP CP ance
PrOZo1Sp1 34 Offices (Partitions<3.5ftbelow
3,227
1 5 4 PASSES
ceiling) Open plan offices 900 ft or
larger with partitions higher
PrOZo2Spl 39 Shop (Non -Industrial) - Machinery
11.676
1 6 6 PASSES
PASSES
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22
Project: COLEMAN
Title: COLEMAN FLOOR COMPANY
Type: Office (Business)
Location: FORT PIERCE, ST LUCIE COUNTY,
FL (661100)
(WEA File: DAYTONABEACH.
System Report Compliance
SS-1 System 1
Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr
I
Component Category
Capacity Design Eff Design IPLV
Comp-
Eff Criteria IPLV Criteria
liance
Cooling System Air Cooled <65000 Btu/h
10.00 10.00 10.00
PASSES
Cooling Capacity
Air Handling System Air Handler (Supply) -
0.80 0.80
PASSES
-Supply Constant Volume
SS-2 System 2
Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr
I
Component Category
Capacity Design Eff Design IPLV
Comp-
Eff Criteria IPLV Criteria
liance
Cooling System Air Cooled < 65000 Btulh
10.00 10.00 10.00
PASSES
Cooling Capacity
Air Handling System Air Handler (Supply) -
0.80 0.80
PASSES
-Supply Constant Volume
PASSES
Plant Compliance
Description Installed Size Design
No Eff
Min Design Min Category
Eff IPLV IPL
Comp
liance
None
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22
Project: COLEMAN
Title: COLEMAN FLOOR COMPANY
Type: Office (Business)
Location: FORT PIERCE, ST LUCIE COUNTY, FL (661100)
(WEA File: DAYTONABEACIL
Water Heater Compliance
DDesign
Description Type Category
Elf
Min Design Max Comp
Eff Loss Loss liance
Water Heater 1 Storage Water Heater - <=120 [gal] & <= 1.00
0.88 PASSES
Electric 12 [kW]
PASSES
Project: COLEMAN
Title: COLEMAN FLOOR COMPANY
Type: Office (Business)
Location: FORT PIERCE, ST L
Piping System Compliance
Category
Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance
[inches] Runout? Temp [Btu-in/hr Thick [in] Thick [in]
[F] SF.FJ
Heating System (Steam, Steam
0.50 False 105.00 0.24 1.00 1.00 PASSES
Condensate, & Hot Water)
PASSES
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22
Project: COLEMAN
Title: COLEMAN FLOOR COMPANY
Type: Office (Business)
Location: FORT PIERCE, ST L
Other Required Compliance
Category
Section
Requirement (write N/A in box if not applicable)
Check
Infiltration
406.1
Infiltration Criteria have been met
System
407.1
HVAC Load sizing has been performed
Ventilation
409.1
Ventilation criteria have been met
ADS
410.1
Duct sizing and Design have been performed
T & B
410.1
Testing and Balancing will be performed
Electrical
413.1
Metering criteria have been met
Motors
414.1
Motor efficiency criteria have been met
Lighting
415.1
Lighting criteria have been met
O & M
102.1
Operation/maintenance manual will be provided to owner
Roof/Ceil
404.1
R-19 for Roof Deck with supply plenums beneath it
Report
101
Input Report Print -Out from EnergyGauge F1aCom attached?
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22
7
1
ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Community Affairs
EnergyGauge F1aCom v1.22
INPUT DATA REPORT
Proiect Information
Project Name:
COLEMAN
Orientation:
North
Project Title:
COLEMAN FLOOR COMPANY
Building Type:
Office (Business)
Address:
Building Classificatio
New Finished building i
COMMERCIAL CIRCLE
State:
FLORIDA
No.of Storeys:
1
Zip:
0
GrossArea:
14903
Owner:
Zones
No Acronym Description Type Load Profi Area Multiplier Total Area
ls9 [st]
I PrOZ01 Zone l CONDITIONED Uses Building Load 3227.0 1 3227.0 ❑
Profile
2 PrOZo2 Zone 2 UNCONDITIONED Uses Building Load 11676.0 1 11676.0 ❑
Profile
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22 I 1
Spaces
No Acronym Description
Type
Depth Width
Height Multi Total Area
Total Volume
[ft] [ftl
[ft] plier
[sq
[cf]
In Zone: PrOZol
1 PrOZo1SD1 Zo0Sp1
Offices (Partitions<3.5 ft
100.00 32.27
10.00 1
3227.0
32270.0
❑
below ceiling) Open plan
offices 900 ft or larger with
partitions higher
In Zone: PrOZo2
I PrOZo2SD1 ZoOSpl
Shop (Non -Industrial) -
100.00 116.76
20.00 1
11676.0
233520.0
❑
Machinery
Lighting
NO Type
Power
Control Type
No.of
[W]
Ctrl pts
In Zone: PrOZol
In Space: Pr0Zo1Sp1
1 Recessed
Fluorescent - No vent
4921.00
Manual On/Off
5
❑
In Zone: PrOZo2
In Space: Pr0Zo2Sp1
1 Metal Halide
8150.00
Manual On/Off
6
❑
Walls
No Description
Type Width H (Effec) Multi Area
DirectionConductance
Heat
Dens. R-Value
[ft] [ft]
plier [sf]
[Btu/hr. sf. F]
Capacity
[Ih/cf] [h.sCFBtul
[Btu/sf.F]
In Zone: PrOZol
I PrOZolWal
8 in. split -face 50.00 10.00 1 500.0
East 0.1301
5.5406
33.981 7.68
❑
CMU, 1-1/2"metal
furring strips
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22
2 PrOZolWa3
8 in. split -face
66.00
10.00 1
660.0
South
0.1301
5.5406
33.98 7.68
❑
CMU, 1-1/2"metal
furring strips
3 PrOZOI Wa4
8 in. split -face
70.00
12.00 1
840.0
North
0.1301
5.5406
33.98 7.68
❑
CMU, 1-1/2"metal
furring strips
Windows
No
Description Type
Shaded UCen
SC Vis.Tr
W
H (Effec)
Mult
Total Area
[Btu/hr sf F
[it]
[ft]
iplier
[Sf]
In Zone: PrOZol
In Wall: PrOZo1Wa1
1
PrOZolWalWil SINGLECLEAR No
1.0018
0.95 0.88
26.00
5.00
1
130.0
❑
In Wall: PrOZo1Wa3
1
PrOZolWa3Wil SINGLE CLEAR No
1.0018
0.95 0.88
4.00
5.00
3
60.0
Doors
No Description Type
Shaded? Width
H (Effec) Multi
Area
Cond.
Dens. Heat Cap. R-Value
[it]
[ft] plier
[sf] [Btu/hr. sf. F] [Ib/cf] [Btu/sf. F] [h.sf.F/Btu]
In Zone: PrOZol
In Wall:
PrOZo1Wal
1
PrOZolWalDrl Aluminum door,
No
3.00
7.00 2
21.0
0.1919
43.67
0.53 5.21
❑
1.25 in.
polystyrene
In Wall:
PrOZo1Wa3
1
PrOZolWa3Drl Aluminum door,
No
3.00
7.00 1
21.0
0.1919
43.67
0.53 5.21
❑
1.25 in.
polystyrene
In Wall:
PrOZo1Wa4
I
PrOZolWa4Dr1 Aluminum door,
No
3.00
7.00 4
21.0
0.1919
43.67
0.53 5.21
❑
1.25 in.
polystyrene
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22 1 3
Roofs
No Description
Type
Width
H (Effec) Multi Area
Tilt Cond. Heat Cap
Dens. R-Value
[1t]
[ft] plier [sf]
[deg] [Btu/hr. Sf. F] [Btu/sf. F] [Ib/cf] [h.sf.FBtu]
In Zone: PrOZol
1 PrMulRfl
MtlBldg Roof/R-19
32.27
100.00 1 3227.0
0.00 0.0492 1.34
9.49 20.34
❑
Batt
In Zone: PrOZo2
I PrOZo2Rfl
Mtl Bldg Roof/R-19
116.76
100.00 1 11676.0
0.00 0.0492 1.34
9.49 20.34
❑
Batt
Skylights
No Description Type
UCen Shading Vis.Tran
W H (Effec) Multiplier
Area Total Area
[Btu/hr sf F Coeff
[ft] [ft]
[S11 [Sf]
In Zone:
In Roof:
Floors
No Description
Type
Width
H (Effec) Multi Area
Cond. Heat Cap. Dens.
R-Value
[ft]
[ft] pher [sf]
[Btu/hr. sf. F] [Btu/sf. F] [lb/cf]
[h.sLFBtu]
In Zone: PrOZOI
1 PrOZolFII
1 ft. soil, concrete
32.27
100.00 1 3227.0 0.1745 54.00 108.00
5.73
❑
floor, carpet and
rubberpad
In Zone: PrOZo2
I PrOZo2Fl1
1 ft. soil, concrete
116.76
100.00 1 11676.0 0.1745 54.00 108.00
5.73
❑
floor, carpet and
rubber pad
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22
Systems
SS-1 System 1
Constant Volume Air Cooled Split
System < 65000 Btu/hr
No. Of Units 1
Component Category
Capacity Efficiency
B'LV
1 Cooling System (Air Cooled < 65000 Btu/h Cooling
Capacity)
2 Air Handling System -Supply (Air Handler (Supply) -
Constant Volume)
60000.00 10.00
1700.00 0.80
10.00
❑
❑
SS-2 System 2
Constant Volume Air Cooled Split
System < 65000 Btu/hr
No. Of Units 1
Component Category
Capacity Efficiency
1PLV
1 Cooling System (Air Cooled < 65000 Btu/h Cooling
Capacity)
2 Air Handling System -Supply (Air Handler (Supply) -
Constant Volume)
60000.00 10.00
1700.00 0.80
10.00
❑
❑
Plant
Equipment Category
Size Inst.No Et% IPL
LI
Water Heaters
W-Heater Description Capacit Cap.Unit
IT Rt. Efficienc
Loss
1 Storage Water Heater - Electric 40 Gal
5 [M] 1.0000 [EF]
[%/hr]
❑
Ext-Lighting
II Description Categories. Area/Len/No. of units Wattage
[sVft/No] [W] 11
311812004 EnergyGauge FlaCom FLCCSB v1.22 i 5
Piping
No Type
Operating
Temperature
[F]
Insulation
Conductivity
[ Btu-in/h.sf.F]
Nomonal pipe
Diameter
[in]
Insulation Is Runout?
Thickness
[in]
1 Heating System (Steam, Steam Condensate, &
Hot Wat
105.00
0.24
0.50
1.00 No ❑
Fenestration Used
Glass Frame Frame
Name Glass Type No. of SC VLT
Panes Conductance Conductance Absorptance
[Btu/h.sLF] [Btu/h.sf.F]
ApLbWndl SINGLE CLEAR 1 1.0018 0.9500 0.8810 0.4340 0.7000 ❑
Materials Used
OnlyR-Value
RValue Thickness
Conductivity
Density
SpecificHeat
Mat No
Acronym
Description
Used
[h.sf.FBtu]
[ft]
[Btu/h.ft.F]
[lb/cf]
[Btu/lb.F]
18
Mat118
2 in. Wood
No
2.3857
0.1670
0.0700
37.00
0.3900
❑
264
Mat1264
ALUMINUM, 1/16IN
No
0.0002
0.0050
26.0000
480.00
0.1000
❑
214
Mat1214
POLYSTYRENE, EXP.,
No
5.2100
0.1042
0.0200
1.80
0.2900
❑
187
Mat1187
1-1/4IN,
GYP OR PLAS
No
0.4533
0.0417
0.0920
50.00
0.2000
❑
BOARD,1/21N
0.3300
❑
206
Mat1206
CELLULOSE,FI LL,5.5IN,R-
No
20.8318
0.4583
0.0220
3.00
151
Mat1151
20
CONC HW, DRD, 140LB,
No
0.4403
0.3333
0.7570
140.00
0.2000
❑
4IN
❑
178
Mat1178
CARPET W/RUBBER PAD
Yes
1.2300
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22 6
265
Mat1265
Soil, 1 ft
No
2.0000
1.0000
0.5000
100.00
012000
❑
48
Mat148
6 in. Heavyweight concrete
No
0.5000
0.5000
1.0000
140.00
0i2000
❑
123
Matll23
CONC BLOCK
No
1.7227
0.6667
0.3870
53.00
0!2000
❑
MW,81N,HOLLOW
1
159
Matl159
CONC
No
0.3202
0.3333
1.0410
140.00
0:2000
❑
HW-UNDRD-140LB-4IN
57
Mat157
3/4 in. Plaster or gypsum
No
0.1488
0.0625
0.4200
100.00
0.2000
❑
72
Mat172
AIR LAYER, 3/41N OR
Yes
0.9000
❑
LESS, VERT. WALLS
267
Mat1267
0.75"stucco
No
0.1563
0.0625
0.4000
16.00
02000
❑
266
Mat1266
2x4@16" oc+R1I Batt
No
8.3343
0.2917
0.0350
9.70
0.2000
❑
215
Mat1215
POLYSTYRENE, EXP.,
No
8.3350
0.1667
0.0200
1.80
0.2900
❑
2IN,
105
Mat1105
CONC BLK HW, 8IN,
No
1.1002
0.6667
0.6060
69.00
02000
❑
HOLLOW
256
Mat1256
WOOD, SOFT,1-1/2IN
No
1.8939
0.1250
0.0660
32.00
0.3300
❑
42
Mat142
8 in. Lightweight concrete
No
2.0212
0.6670
0.3300
38.00
0.2000
❑
block
269
Mat1269
.75" ISO BTWN24" oc
No
2.2321
0.0625
0.0280
4.19
0.3000
❑
86
Mat186
BRICK, COMMON, 41N
No
0.8012
0.3333
0.4160
120.00
0.2000
❑
211
Mat12ll
POLYSTYRENE,EXP.,1/21
No
2.0850
0.0417
0.0200
1.80
0.2900
❑
N,
12
Mat112
3 in Insulation
No
10.0000
0.2500
0.0250
2.00
0.2000
❑
218
Mat1218
POLYURETHANE,EXP.,1/2
No
3.2077
0.0417
0.0130
1.50
0.3800
❑
IN,
23
Mat123
6 in. Insulation
No
20.0000
0.5000
0.0250
5.70
0.2000
❑
4
Mat14
Steel siding
No
0.0002
0.0050
26.0000
480.00
0.1000
❑
271
Mat1271
2x4@24" oc+RI1 Batt
No
10.4179
0.2917
0.0280
7.11
0.2000
❑
272
Ivlatl272
Panel with 7/16" panels
Yes
0.9044
❑
273
Mat1273
Hollow core flush (1.375")
Yes
1.2777
❑
274
Mat1274
Solid core flush (1.375")
Yes
1.7141
❑
275
Mat1275
Panel with 7/16" panels
Yes
1.0019
❑
(1.375")
276
Mat1276
Hollow core flush (1.75")
Yes
1.3239
❑
277
Mat1277
Panel with 1-1/8" panels
Yes
1.7141
❑
(1.75")
278
Mat1278
Solid core flush (1.75")
Yes
1.6500
❑
279
Mat1279
Solid core flush (2.25")
Yes
2.8537
❑
311812004 EnergyGauge FlaCom FLCCSB vl.22 7
E
280
Mat1280
Fiberglass/Mineral wool core
Yes
0.8167
❑
f
281
Mat1281
Paper Honeycomb core
Yes
0.9357
❑
282
Mat1282
Solid Urethane foam core
Yes
1.6500
❑
283
Mat1283
Solid mineral fiberboard core
Yes
1.7816
❑
284
Mat1284
Polystyrene core (18 ga steel)
Yes
2.0071
❑
1
285
Mat1285
Polyurethane core (IS ga
Yes
2.5983
❑
steel) 2
286
Mat1286
Polyurethane core (24 ga
Yes
2.5983
❑
steel) 1
287
Mat1287
Polyurethane core (24 ga
Yes
4.1500
❑
steel) 2
288
Mat1288
Solid Urethane foam core
Yes
4.1500
❑
81
Matl81
ASPHALT -ROOFING,
Yes
0.1500
❑
ROLL
244
Mat1244
PLYWOOD, 1/21N
No
0.6318
0.0417
0.0660
34.00
0.2900
❑
185
Mat1185
CLAY TILE, PAVER, 3/81N
No
0.0301
0.0313
1.0410
120.00
0.2000
❑
82
Mat182
ASPHALT -SHINGLE AND
Yes
0.4400
❑
SIDING
11
Matll l
2 in. Insulation
No
6.6800
0.1670
0.0250
2.00
0.2000
❑
47
Mat147
2 in. Heavyweight concrete
No
0.1670
0.1670
1.0000
140.00
0.2000
❑
95
Mat195
CONC BLOCK
No
0.7107
0.3333
0.4690
101.00
0.2000
❑
HW-4IN-HOLLOW
248
Mat1248
ROOF GRAVEL OR
No
0.0500
0.0417
0.8340
55.00
0.4000
❑
SLAGI/21N
94
Mat194
BUILT-UP ROOFING, 3/81N
No
0.3366
0.0313
0.0930
70.00
0.3500
❑
3/18/2004
Constructs Used
EnergyGauge FlaCom FLCCSB v1.22
8
No
Name
Simple
Massless Conductance
Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F[
[Btu/sfF]
[Ib/cQ
[h.sf.FBtu]
1002
Aluminum door, 1.25 in. polystyrene No
No 0.19
0.53
43.67
5.2104
❑
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
264
ALUMINUM, 1/16IN
0.0050
0.00
❑
2
214
POLYSTYRENE, EXP., 1-1/41N,
0.1042
0.00
❑
3
264
ALUMINUM, 1/16IN
0.0050
0.00
❑
Simple
Massless Conductance Heat Capacity
Density
RValue
No
Name
Construct
Construct [Btu/h.sf.F]
[Btu/sEF]
[Ib/ct]
[h.sf.FBtu]
1005
1 ft. soil, concrete floor, carpet and rubber pad No
No 0.17
54.00
108.00
5.7300
❑
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
265
Soil, 1 ft
2.0000
0.00
❑
2
48
6 in. Heavyweight concrete
0.5000
0.00
❑
3
178
CARPET W/RUBBER PAD
0.00
❑
Simple
Massless Conductance Heat Capacity
Density
RValue
No
Name
Construct
Construct [Btu/h.sf.F]
[Btu/sf.F]
[lb/cf]
[h.st:FBtu]
1011
8 in. split -face CMU, 1-1/2"metal furring No
No 0.13
5.54
33.98
7.6845
❑
strips @ 16" O.C. W/ R-8 Insulation
Layer
Material
Material
Thickness
Framing
No.
[ft]
Factor
1
42
8 in. Lightweight concrete block
0.6670
0.00
❑
2
214
POLYSTYRENE, EXR, 1-1/41N,
0.1042
0.00
❑
3
187
GYP ORPLAS BOARD,1/2IN
0.0417
0.00
❑
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22 1
9
I
No Name
Simple
Construct
Massless Conductance Heat Capacity
Construct [Btu/h.sf.F] [Btu/sf.F]
Density
[Ib/cf]
RValue
[h.sf.FBtu]
1047 Mtl Bldg Roof/R-19 Batt
No
No 0.05 1.34
9.49
20.3366
❑
Layer Material
Material
Thickness Framing
No.
[ft] Factor
1 94
BUILT-UP ROOFING, 3/SIN
0.0313 0.00
❑
2 23
6 in. Insulation
0.5000 0.00
❑
3/18/2004 EnergyGauge FlaCom FLCCSB v1.22 10
N1' RN-11 auaN la5ulo0
6 1811E 61:16 11 W N sal uoJ6aJd aludlauil
(paylaN uaillunl JadsuodJ) 110/6118 :A6alopaglaN pool 6uiloa]
JagUdiad of AJunuo£ :paiJad uoilolnuiS ualsAS
JaquanaN of aun£ :pmJad uoilaln IS u6isa0
(ldn/Jglviu-ql) 6099'6 Jal;a1 Adliqu3
(}dna/Jq/ Ulu -ND 6'HO :Jalaol loaN lualol
(11ldmLJq/viu-n18) L6IIl :paid loaN7idnadS-Alisua0
(1/uql/nl8) 666d'0 Ilq iij!AS Jiy
(UnIME 09L0'0 :Alisua0 Jiy
08.0
:aauolialiq punaJ9
JaluiA
02A
:alualaaldaN punaJ9
JauunS
(1) 8E
:g1n0 Aig u6tsa0
Jalwp
(1) 8L
gln8 JaA u615a0
JauunS
(1) 89
:gln0 AJN u6isa0
JauunS
S6'0
:JaqunN ssaujIdIj
Jalulm
961
:JaqunN 5saudaal]
JauunS
(OH 'uI) 6'62
:adnssaJd IIJIaUOJag
(ld) 91
:u01lonall
g
:auaL aull
AN L'09
:apnli6ual
(cap) 1'82
:apnl!Jal
ua i laial
NNn813N
:apoj 31il Jaglaa0
RHO) S
al '911833N19N3 1Stl9 6
91 N]NV £
MIN 112
9N180011 NtlN3100 1
InI1711x131IllnIISIInl23ln3;133;11n3x37xiix3lii;i;;;nni113n32;7lniix
313357113532323iflS313fl3333733333i313ii131x323l333333733313113;3733235333137
3i 33
li 9NIII)m 'S'0'] Aq n
n n
n SISA1tlNtl 009 3�tlN1 n
3; 73
3832313332213I31113723313332331333;333133I31332l32131133321;83l3I33;331I231
33;1311331371333i3I3122S333i133I132773S7;3I333373l3I3i31312333333213113313323
0 19tld 9N113N8VN 'S'0'9 :A8
009 A snuauaI3 6wuallipuo0 ily amil
Iran Air Conditioning Economics
By: C. B. S. MARKETING
AIRFLOV - ALTERNATIVE I
V 600
PAGE I
-----------------------------------
S Y S
I E H S U M M A R Y ----------------------------------
(Design Airflow
Duantities)
-------------------------
gain --------
--
Auxil.
Room
Outside
[Doling
Heating
Return
Exhaust
Supply
Exhaust
System System AirFlow
AirFlor
Airflow
Airflow
AirFlow
Airflow
Airflow
Number Type (Ern)
(Ern)
(Cfn)
(Cfn)
(Cfn)
(Cfn)
(CFn)
I SZ 537
3,4111
3,4111
3,4111
537
D
D
Totals 537
3,4111
3,4BI
3,491
537
D
D
CAPACITY - ALTERNATIVE I
SYSIIH SUHNARY
(Design Capacity Duantities)
---------------
Cooling ---------------
---------------------------------
Heating ----------------------------------
Hain Sys.
Aux. Sys. Opt. Vent
Cooling
Hain Sys. Aux. Sys.
Preheat
Reheat
Hunidif. Opt. Vent
Heating
System System Capacity
Capacity Capacity
Totals
Capacity Capacity
Capacity
Capacity
Capacity Capacity
Totals
Number Type (Tons)
(Tons) (Tons)
(Tons)
(Btuh) (Btuh)
(Btuh)
(8tuh)
IBtuh) IBtuh)
(Btuh)
I S1 9.6
D.0 O.D
9.6
-B5,719 D
0
D
D 0
-115,710
Totals 9.6
D.0 0.0
9.6
-85,710 D
D
D
0 0
-B5,71D
The building peaked at hour 16 month B with a capacity of 9.2 tons
ENGINEERING CHECKS - ALTERNATIVE I
------------------------------------ E N G I N E E R I N G C H E C K S -------------------------------------
Percent ------------- Cooling -------------- --- Heating ----
System Main/ System outside CFn/ Crn/ Sq Ft Btuh/ Cfn/ Btuh/ Floor Area
Number Auxiliary Type Air Sq It Ton /Ton Sq rt Sq Ft Sq Ft Sq It
t Hain SZ 15.42 I.17 363.2 311.0 3B.5B I.17 -2B.75 2,9B1
Trane Air Conditioning E[ononi[s V 6DD
By: C. D. S. MARKETING PAGE 2
SYSTEM CHECKSUMS Systen I Peak SZ - SINGLE ZUNE SYSTEM
[FEFFFIIEIFIFFIIIEIFEFIFF CODLIMG COIL .PEAK FF[I[EIEEEEEEEF[EEREFEEEEi[FIII CLG. SPACE PEAK. EFFEEEFEIEEI HEATING _[OIL _PEAK . E[i[[IFI
Peaked at Tine =_) Mo/Hr: B/16 I No/Hn 9115 E Ho/Hr: 131 1
Outside Air =_) OADB/WB/NR: BY 7B/133.0 [ DADB: B6 [ DADB: 3B
I F
SpaEe Rot. Air Ret. Air Net Per[nt [ Spa[e PerEnt I Spa[e Peak Coil Peak Per[nt
Sens.+Lat. Sensible Latent Total OF Tot I Sensible OF Tot I Spa[e Sens Tot Sens OF Tot
Envelope Loads IBtuh) (Btuh) (Btuh) (Btuh) (7.) I (Btuh) ('Z) I (Btuh) (Btuh) (%)
Skylite Solr 0 0 D 0.00 I B 0. Do i D D D . D 0
Skylite Cond 0 0 D D.DD E D D.BD I D D D.DB
RooF Cond D 9,377 9,377 B.15 I 0 D.Do E 0 -4, 25D 4.96
Glass Solar 15,2D0 D 15,20D 13.22 F 17,41D 23.62 I D D D.OD
Glass Cond 1,75D D 1,750 1.52 F 1,134 1.54 F -7,B66 -7,066 9.IB
Wall Cond 2,B97 6D7 3,504 3.05 I 3,015 4.09 i -3,39D -4,3D4 5.02
Partition I, 463 1,463 1.27 I 1,375 I.B7 x -4,646 -4,646 5.42
Exposed Floor 0 B D.0D I 0 0.00 I D D 0.0D
Infiltration 0 0 0.00 I D D.DB I -t -1 D.BD
Sub Total==) 21,311 9,9B4 31,295 27.21 E 22,934 31.It F-15,9D3-2I,061 24.5E
Internal Loads I I
Lights l6, 792 0 16,792 14. 69 [ 16, 792 22. 76 I D 0 D.Do
People 13,420 13,420 11.67 E 6,710 9.1D F 0 D 0. Do
Nis[ 17, 666 D D 17, 666 15.36 F 17, 666 23. 96 I 0 D D.DD
Sub Total==) 47, B7B D B 47378 41.63 I 41,166 5534 i 0 D D.DD
Ceiling Load 9,964 -9,9B4 D D.DD I 9,61B 13.05 I -5,164 D 0. Do
Outside Air D D D 32,129 27.93 I D D.DD E D-23,345 23.74
Sup. fan Heat 3,713 3.23 [ D.DD E 0 D.DD
Rot. fan Heat D 0 D.DD E D.Do i D D.BD
DuEt Heat Pkup D D D.DD E 0.00 I D D.BD
OV/UNOR Sizing D D D.00 I D D.DD I-44,29B -44,29B 51.6E
Exhaust Heat 0 0 0 D.DD I O.DD [ B D.DD
Terninal Bypass D 0 0 D.DD [ 0.00 I 0 D.DD
[ I
brand Total==) 79,172 0 0 115,D13 IDD.DD F 73,720 100.00 E-65,365 15,71D 100.DO
------------------------------------COOLING COIL SELECTION----------------------- -- AREAS --------------
Total Capiiity Sens Cap. Coil Airfl Entering DB/WB/HR Leaving DB/WB(HR Gross Total Glass (sf) (K)
(Tons) (gbh) (Mbh) (Ern) Deg F Deg F Grains Deg F Deg F Grains floor 2,9BI
Main 110 9.6 115.0 B3.2 3,461 76.B 64.6 71.7 55.0 53.7 59.3 Part I'm
Aux 110 0. D D. B 0. 0 D 0.0 D. D 0. 0 0. 0 0.0 D. D ExF lr 0
Opt Vent 0.0 D. 0 U. 0 D 0.0 D. B D. 0 D. 0 D. D 0. D RooF 2, 9BI D 0
Totals 9.6 115.D gall 1,070 t9D to
-----------HEATING COIL SELECTION --------AIRFLOWS ([fn)- ENGINEERING CHECKS-- --TEMPERATURES (F)---
Capa[ity Coil AirFl Ent Lvg Type Cooling Heating CID'L OA 15.4 Type CID Htq
IMbh) ([Fn) Deg F Deg f Vent 537 537 mg Crn/Sgrt 1.17 SAID 56.0 BB.B
Hain HtD 15.7 3,4B1 66.B BB.B Inril 0 D LID Crn/Ton 363.16 Plenun B5.6 66.5
Aux Htq D.D D 0.D D.0 Supply 3,4BI 3,4BI CID Sgft/Ton 3II.D3 Return 75.D 72.0
Preheat -D.D 3ABI 66.B 55.0 Min[Fn D D ClgBtuh/Sgft 3B.5B Ret/DA 76.B 66.B
Reheat 0.D D 0.9 0.0 Return 3,4BI 3,4BI No. People 27 Runarnd 75.0 72.D
Hunidir 0.D D 0.0 0.D Exhaust 537 537 Htg % OA 15.4 In MIT 0.2 D.0
Opt Vent D.0 0 D.B 0.9 RA Exh D 0 Htg CFn/SgFt 1.17 In BldfD 0.2 0.0
Total -B5.7 Auxit D 0 Htg Btuh/Sgft -2B.75 In fri[t 0.5 D.0
Product Review Affidavit
St Lucie County, Public Works Department
Code Compliance Division
The following products will be installed in the structure located at ebwmwa Qttcl p Pr fteR[e1 t �
Building Permit #
Owners Name COt MAV3 RCOF, (IMPALA' Y Owner's Address NCO ToLLVIM lk. *LL)46 ArIEdl lid IL la=B
Contractor CD►d5T1a5GM�4� 6,7c. Contractor's Address 1465 &NSZ WiNtKfac.FL 327FA
*Product Rated I Manufacturer (Model Number[ Method of Attachment
Windows * Fifi in doe rated wind design pressures listed by the manufacturerfor each product fisted
1st Choice NIA
Mullions
ized Glass
1st Choice
4,0 -4O CSF
YW
AFAMWJCA
M-Ieo
icrA
3%t(osX 341�fCoNS @ 8°!]L .
Skylights
1st Choice
.I -bp (gyp fW
CE0 QtKrfo
ICWL IS(M.
MA**4%Y "rvAW. 1t1R
2nd Choice w.�w
Overhead Garage Doors CraL L)r)
1st Choice t8- by m
2nd Choice mom,
Roofing Material
AsphaltTiberglass
Metal
-AM MOM
ILDI" ?wr
NCS
MP LIiiMT,.
Other
I I I I ";( M'ef
I have reviewed the above components and cladding, and have approved their use'in,the structure
provide adequate resistance to the wind loads and forces specified by curre nt co ro�"toies: e ,
Name: MICMAEL'D. aVANA1366' Si
rr
Design Firm rAg AA'1N16wI11RS 6. A4M %Merl- No. GiDI$_ te:
fAGt &fJ
St. Lucie County
Building and Zoning Department
2300 Virginia Avenue
Fort Pierce, FL 34982
ON-462-1553
'172 - -- - - ---
Design Certification for Wind Load Compliance
This Certification is to be completed by the project design architect or engineer. 71is Certification must be submitted with all
applications for building permits involving the construction of new residence (single or multi- family), residential addition, any
accessory structure requiring a building permit, and any nonresidential structure. This Certification "not apply to interior
renovations (provided that no structural walls, columns or other similar component is being effected) and certain other minor building
permits. For Anther assistance, please contact the Building Inspection Office at 462-1553 or 462-2172.
Project Name
I fLM"VA. FLCOK (O
Office Use Only
Street Address
Permit Number
FIEWe., SL
IOceType
Construction Type
Certification Statement:
I certify that, to the best of my knowledge and belief, these plans and specifications have been designed to
comply with the applicable structural portion of the Building Codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the wind
loads and forces specified by current code provisions.
Desien Parameters and Assumptions Used: (Please check or complete the appropriate box.)
1. Florida Building Code 2001 Edition l fo0to . ASCE 7-98 ✓
2. Building Design is (check one) Enclosed ✓ Partially Enclosed Open Building
3. Building Height: 2 01t 4. Wind Speed Used in Building Design: 140 MPH 3 second gust
S. Wind Exposure Classification (refer to exposure tables in Building Code identified In Line #1): 15
6. Average Wind Velocity Pressure on Exterior Faces of Structure 1? PSF
7. Peak Wind Velocity Pressure on Exterior Faces of Structure 35.0 PSF
8. Importance/Use Factor (obtain from Building Code):. I W • O
9. Loads: Floor �?!� _PSF Roof/dead >= PSF Roof/live '2D PSF
10. Were Shear Walls Considered for Structure (cbeek one): Yes ✓ No _(if No, attach explanation)
11. Is a Continuous Load Path Provided (check one): Yes _ // No (if No, attach explanation)
12. Are Component and Cladding Detail Provided (check one): Yes ✓ No _(if No, attach explanation)
13. Minimum Soil Bearing Pressure: 2060 PSF
As witnessed by my seal, I hereby certify that the information included with this certification is true and
correct, to the best of my knowledge and belief. , , ) �. ,
Name: M!CoN EL D CA✓8AWO- F Certification #: `''[Seal Here]
Design Firm: Ax A & ffE= 9. tdgjR • , hliI . Date: -J_
/A 0002811
SLCCDV Form # 020.00
1-KI5JUIR t1 INE 11l ' 1340/399 04/19/04 03:Slpm P. 002
BOAR® OF
COUNTY
COMMISSIONERS
March 26, 2004
Mr. Joseph T. Friscia, P.E.
Friscia Engineering, Inc.
681 SW Whitmore Drive
Port St. Lucie, Florida 34984
SST LLuC' E
COUNTY 4
Subject: , Coleman Flooring -Minor Site Plan
Dear Mr. Friscia:
The St. Lucie County Community Development Director has granted your
request far minor site plan approval of the above referenced project. This site plan
approval becomes effective immediately. Enclosed is an unrecorded copy of the
resolution. A recorded copy of the resolution will be forwarded to you upon its receipt
by this office from the Clerk of the Court.
Please contact me at 772/462-1582 if you have any questions.
Sincerely,
Hank Flores, AICP
Development Review Planner III
hf
cc: File
IOHN D. URIINN. Disma No. 9 • DOUG COWARD. Diwila No. 2 a PAUTA A. LM Dim, Ho. 3 • FMNNIE HUTCHINSON, Diurkl No. 4 - CLIFF BARNES, Disma No- 5
Coum v Adminisrro+or - Douglas M. Anc enw
2300 Virginia Avenue • Farr Pierce, FL 34982-5652
Administration: (772) 462-1590 - Planning: (772) 462-2822 G15lredinicol Services: (772) 462-1553
Economic Development: (772) 462-1550 Fox: (772) 462-1581
Tourisr/Convention: (772) 462-1529 • Fox: (772) 462-2132
vvvvw.co.srludeJJ.us
FRI 5G1A ETXoiry v liW
ssio40S3o
04/19/04 03:Slpm P. 003
1
2
3
4
s
6
7
e
9
10
11
12
13
�E-1.
is
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
46
41
CD-04-006
fiW174 G-003
AN ORDER GRANTING APPROVAL FOR A
MINOR SITE PLAN KNOWN AS COLEMAN
FLOORING
WHEREAS, the St. Lucie County Community Development Director has reviewed the
application for site plan approval submitted by Friscia Engineering, reviewed the comments
of the St. Lucie County Development Review Committee on this application, and made the
following determinations:
1. Coleman Flooring, is a proposed 14,986 square foot distribution facility for property
located on Commercial Circle in the Kings Highway Industrial Park in the IL
(Industrial, Light) Zoning District.
2. The Development Review Committee has reviewed the site plan for the proposed
project and found itto meettechnical requirements of the Land Development Code
and to be consistent with the St. Lucie County Comprehensive Plan.
3. The project is consistent with the general purpose, goals, objectives, and standards
of the St. Lucie County Comprehensive Plan and the St. Lucie County Land
Development Code.
4- The project will not have an undue adverse effect on adjacent property, the
character of the neighborhood, traffic conditions, parking, utility facilities, or other
matters affecting the public health, safety, and general welfare.
5. All reasonable steps have been taken to minimize any adverse effect of the
proposed project on the immediate vicinity through building design, site design,
landscaping, and screening.
6. The project will be constructed, arranged, and operated so as not to interfere with
the development and use of neighboring property, in accordance with applicable
district regulations.
7. The project is to be served by adequate public facilities and services.
8. The applicant has applied for and received an updated certificate of capacity, a
copy of which is attached to this order as Exhibit A, as required under Chapter V, St.
Lucie County Land Development Code.
File No.: MNSP-04-003 Go Order 04-006
March 26, 20N
Page 1
r r«a:::r-i erv�:rveerci rv� bb1:3410 i��
04l19l04 oa:51pm V. 004
1
2
3
4
5
6
7
- s
9
to
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
NOW, THEREFORE, BE IT ORDERED:
A. Pursuant to Section 11.02.03 (D) of the St. Lucie County Land Development Code,
the proposed Minor Site Plan known as Coleman Flooring, is hereby approved as
shown on the site plan drawings for the project prepared by Friscia Engineering,
dated March 10, 2004, and received by the St. Lucie County Community
Development Director on March 23, 2004, on the property described as follows:
LOT 23, BLOCK B, KINGS HIGHWAY INDUSTRIAL PARK, UNIT2, AS RECORDED IN PLAT
BOOK 32, AT PAGE 5'OF THE PUBLIC RECORDS OF ST. LUCIE COUNTY, FLORIDA.
(TAX ID. It: 1335-802-0045-00011)
(Location: Commercial Circle, Kings Highway Industrial Park)
B. The approvals granted by this administrative order shall expire on March 26, 2006,
unless a building permit is issued or an extension is granted in accordance with the
provisions of Section 11.02.06 of the St Lucie County Land Development Code.
C. The Final Site Plan approval granted under this Resolution is specifically
conditioned to the requirement that the petitioner, Coleman Flooring, including any
successors in interest, shall obtain all necessary development permits and
construction authorizations from the appropriate State and Federal regulatory
authorities including, but not limited to; the United States Army Corps of Engineers,
the Florida Department of Environmental Protection, and the South Florida Water
Management District, prior to the issuance of any local building permits of
authorizations to commence development activities on the property described in
Part A.
D. A copy of this Order shall be attached to the site plan drawings described in Part A,
which plan shall be placed on file with the St. Lucie County Community
Development Director and mailed, return receipt requested to the developer and
agent of record as identified on the site plan applications.
E. The Certificate of Capacity, attached as Exhibit A, shall be valid forthe same period
as this order. If this order expires or otherwise terminates, the Certificate of
Capacity shall automatically terminate.
File No.: LFNSP-04-003
March 26.2004
CD Order 04-006
Page 2
r KaSL:aP tNL�l NttFCl rvV SS1,"�i41'J ly'tlb'
04/15l04 03:Slpm P. 005
1
2
3
4
s
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
F. This order shall be recorded in the Public Records of St. Lucie County.
ORDER effective the 268i Day of March 2004.
COMMUNITY DEVELOPMENT DIRECTOR
ST. LUCIE COUNTY, FLORIDA
Den,y} s J. Murphy
I
APPROVED AS TO FORM
AND CORRECTNESS:
County Attorney
ht
HaW ORDIPETITIONSIBCC\FINISHED.2004IColemanFloo4nn,SPlColamanFloodnSCDO.doe
File No.: MNSP-04-003
March 26, 2004
CD Order 04-006
Page 3