Loading...
HomeMy WebLinkAboutHOME INSTALLATION SPECIFICATIONSManufactured Home Installation Specifications (Must be completed and submitted with your application) Applicant KIMBERLY CIUFO Address CARLTON RD Permit # RECEIVED SCANNED BY MA2'L Ji9 St. Lucie County R Manufacturers Name DESTINY I ST. Lucie County, Permitting Roof Zone Wind Zone 3 No. of Sections 2 Width Length 76 Installation Standard Used (check) Manufacturers Manual YES Year 2019 Serial # 15C-1 Site Preparation Debris and Organic Removal YES Page # Water Drainage: Natural Swale Pad YES Other Page # Foundation Load bearing soil density 1500 Or assumed 1,000 psf Page # _ Footing type: Poured in place Portable YES Page # _ Mainrail frame block: Size 17X22.5 Placement o.c. Page # _ Perimeter blocking: Size 16X16 Number Location Page # _ Ridge beam support: Number Size Location Page # _ Center line blocking: Number Size Location Page # _ Special supports required (fireplace, bay window) Yes _ No X Page # _ Mating of Units: Mating gasket FACTORY Type used FOAM Page # _ Fasteners: Roof Type GALV Spacing O.C. Page # _ Endwall Type LAG 6" Spacing 24" O.C. Page # _ Floors Type LAG 6" Spacing 24" O.C. Page # _ Anchors: Type 6,000 3,150 Page # _ Height of Unit (top of foundation to frame): Page # _ Angle of straps 45 Page # _ Number of frame ties 20 Spacing 4 O.C. Page # _ Number of over -roof ties (if required) Page # _ Number of sidewall anchors 20 Zone II Zone III Page # _ Number of centerline anchors 20 Number of stabilizers Page # _ Vents required for underpinning (Isf/l50 sf floor area): No. Page # _ Prepared by: Date: Revised 722/2014