Loading...
HomeMy WebLinkAboutINSTALLATION INSTRUCTIONSSCANNED OLIVER TECHNOLOGIES, INC. BY INSTALLATION INSTRUCTIONS FOR FLORIDA St. Lucie County PATENT# 6634150 & OTHER PATENT PENDING VAR 6�'L ST. Lucie County, Pe_ (mom ey REVISED SEAN SWONGER of 6:32 am, aOl/18 E VIEWEDGNGERaf Mam, fl/3f/fa ttJ11 (J�8! 4 , STATE OF :W Oft `pP.N °°JIlI ItJt�� Aug 24, 2018 OLIVER TECHNOLOGIES, INC. FLORIDA INSTALLATION INSTRUCTIONS FOR THE MODEL 1101 "V" SERIES ALL STEEL FOUNDATION SYSTEM MODEL 1101 "V" (Steps 1-14) LONGITUDINAL ONLY: Follow Steps 1-9 LATERAL ONLY: Follow Steps 1-3 and Steps 10-14 ENGINEERS STAMP FOR CONCRETE APPLICATIONS: Follow Steps 15-1a ENGINEERS STAMP 1. SPECIAL CIRCUMSTANCES: if the following conditions occur-STOKContact Oliver Technologies at 1-800-284-7437: a) Pier height exceeds 48" c) Roof eaves exceed 16" e) Location is within 1500 feet of coast b) length of home exceeds 76' d) Sidewall height exceed 96" INSTALLATION OF GROUND PAN t; 2. Remove weeds and debris in an approximate two foot square to expose firm soil for each ground pan (C) . 3. Place ground pan (C) directly below chassis 1-beam. Press or drive pan firmly into soil until flush or belowrsoil xthen install pier per manufacturer's instructions or per Florida Regs. I SPECIAL NOTE: The longitudinal "V" brace system may also serve as a pier under the home and'should be loaded as any other pier. It is recommended that after leveling piers, and one-third inch (1/3") before home is lowered completely on to piers, complete steps 4 through 9 below then remove jacks. INSTALLATION OF LONGITUDINAL "V" BRACE SYSTEM (Madek;1101 L "V") NOTE: WHEN INSTALUNGTHE LONGITUDINAL SYSTEM ONLY, A MINIMUM OF 2 SYSTEMS PER FLOOR SECTION IS REQUIRED. SOILTEST PROBE SHOULD BE USED TO DETERMINE CORRECTTYPE OF ANCHOR PER SOIL CLASSIFICATION. IF PRO13ETESY READINGS ARE BETWEEN 175 & 275 A 5 FOOT ANCHOR MUST BE USED. IF PROBETEST READINGS ARE BETWEEN 276 &350 A 4 FOOT ANCHOR MAYBE USED. USE GROUND ANCHORS WITH DIAGONALTIES AND STABILIZER PLATES EVERY 5'4" . VERTICALTIES ARE ALSO REQUIRED ON HOMES SUPPLIED WITH V/ERTICALTIE CONNECTION POINTS (PER FLORIDA REG.). 4. Choose one of the approved longitudinal tube installations, either Dlaagram'A or B. Then select the correct square tube (E) length from the diagram for appropriate pier height at support location or cut and drill'1.5'square tube to achieve appropriate length. PIER HEIGHT 1.25" 1.50" .,,ti PIER HEIGHT 1.50" (40" Min. - 45" Max.) Tube Length Tube Length %16"oia. (SS21 holey (40" Min. - 60" Max.) Tube Length 7 3/4" to 25" 22" 18" 24 3/4" to 321 /4" _ 32" 33" to 4l" M. '1 40" to 48" 54" i 18", Par: E Diagram A Diagram B S. Install (2) of the 1.50" square tubes (E) intoo they"U" bracket (J), insert carriage bolt and leave nut loose for final adjustment. 6. Place I-beam connector (F) loosely on thebottom flange of the I-beam. 7. (For Diagram A installation) Slide tfie selected 1.25" tube (E) into a 1.50" tube (E) and attach to I-beam connectors (F) and fasten loosely with bolt and nut. (For Diagram B in'stallation) Attach the selected 1.5"tubes (E) to the I-beam connectors (F) and fasten loosely with bolts and nuts. B. Repeat steps 6 through 7 to create the "V" pattern of the square tubes loosely in place. 9. Using standard hand tools tighten all nuts and bolts. (For Diagram A installation only, secure 1.25" and 1 .50" tubes using four(4) 1 /4"-14 x 3/4" self -tapping screws in pre -drilled holes.) 14" to 18" 20" 18" to 25" 28" 24" to 35" 39" 30" to 40" 44" 36"to 48" 54" INSTALLATION OF LATERAL TELESCOPING TRANSVERSE ARM SYSTEM (Model 1101 T"V") THE MODEL 1101 "V" (LONGITUDINAL & LATERAL PROTECTION) ELIMINATES THE NEED FOR STABILIZER PLATES & FRAME TIES. NOTE: THE USE OFTHIS SYSTEM REQUIRES VERTICALTIES SPACED AT5'4". FOUR FOOT (4') GROUND ANCHOR MAY BE USED EXCEPTWHERE THE HOME MANUFACTURER SPECIFIES DIFFERENT. 10. Install remaining vertical tie -down straps and 4' ground anchors per home manufacturer's instructions. NOTE: Centerline anchors to be sized according to soil torque condition. Any manufacturer's specifications for sidewall anchor loads in excess of 4,000 lbs. require a 5' anchor per Florida Code. 11. Select the correct square tube brace (H) length for set-up lateral transverse at support Iocation.The lengths come in either 60" or 72" lengths. (With the 1.50" tube as the bottom tube, and the 1.25' tube as the inserted tube.) 12. Install the 1.50 transverse brace (H) to the ground pan connector (D) with bolt and nut. 13. Slide 1.25" transverse brace into the 150" brace and attach to adjacent 1-beam connector (1) with bolt and nut. 14, Secure 1-50" transverse arm to 1.25" transverse arm using four (4) 1 /4"-14x 3/4" self -tapping screws in pre -drilled holes. Page, PATFNTi! l,A:tAl Sn R, nTHFR PATFNT PFNDINr, Revision 08/23/1E INSTALLATION USING CONCRETE RUNNER/ FOOTER 1 S. A concrete runner, footer or slab may be used in place of the steel ground pan. a) The concrete shall be minimum 2500 psi mix b) A concrete runner may be either longitudinal or transverse, and must be a minimum of 8" deep with a minimum width of 16 inches longitudinally or 18 inches transverse to allow proper distance between the concrete bolt and the edge of the concrete (see below). c) Footers must have minimum surface area of 441 sq. in. (i.e. 21" square), and must be a minimum of 8" deep. d) If a full slab is used, the depth must be a 4" minimum. Special inspection of the system bracket installation is not required. Footers must allow for at least 4" from the concrete bolt to the edge of the concrete. NOTE: The bottom of all footings, pads, slabs and runners must be per local jurisdiction. LONGITUDINAL: (Model 1101 LC"V") 16. When using Part# 1101-W-CPCA (wetset) simply install the bracket in runner/footer OR When installing in cured concrete use Part# 101-D-CPCA (dryset}. The 1101 (dryset) CA bracket is attached to the concrete using (2) 5/8"x3" concrete wedge bolts (Simpson part # 5162300H 5/8" X 3" or Powers equivalent). Place the CA bracket in desired location. Mark bolt hole locations, then using a 5/8" diameter masonry bit, drill a hole to a minimum depth of 3"- Make sure all dust and concrete is blown out of the -holes. Place wedge bolts into drille holes, then place 1101 (dry set) CA bracket onto wedge bolts and start wedge bolt nuts_Take;a hammer a'nd lightly drive the wedge bolts down by hitting the nut (making sure not to hit the top of threads on bolt). The sleeve of conc'r'ete wed a bolt needs to beat or below the too of concrete Complete by tightening nuts. tofc LATERAL: (Model 1101 TC "V" 1 17. For wet set (part # 1101-W TACA) installation simply install the anchor bolt into;iunnerAooter For dry set installation (part # 1101-D TACA mark bolt hole locations, then using a 5/8" diam. masonry bit. drill a hole to a minimum depth of 3". Make sure all dust and concrete is blown out of the hole. Place wedge bolts (Simpson part #5162300H 5/8" X 3" or Powers?equivalent) into (D) concrete dry transverse connector and into drilled hole. If needed, take a hammer and lightly.dfive the wedge bolts down by hitting the nut (making sure not to hit the top of threads on bolt), then remove the nutThe sleeve of concrete wedge Bolt needs to beat or below the too of concrete 18. When using part# 1101 CVW (wetset) or 1101 CVD (dryset), install,pef,kep'sr17& 18. Notes 1. LENGTH OF HOUSE IS THE -ACTUAL BOX SIZE 2.�= LOCATION OFTRANSVERSEBRAE[NGONLY 3 9] = LOCATION OF L6NGITUDINAL--BRACING ONLY 4.0 =TRANSVERSE AN6LONGITUDINALLOCATIONS ENGTHS UP TO 52' ALL WIDTHS AND LENGTHS OVER 52'TO 80" HOMES WITH 5/12 ROOF PITCH REQUIRE: PER FLORIDA REGULATIONS 6 systems for home lengths up to 52' and 8 systems for homes over 52' and up 80'. PATENT# 6634150 & OTHER PATENT PENDING Page 2 Revision 08/23/1 E I -Transverse Arm, I -Bum Connector D-PanTmnsverse H-Transverse Arm / Top (1251 Bottom (151) C-Ground Pan 1-Transverse Arm,1-Beam Connector \\\ Part I llot-O-TACA H-Transverse Arm Partt 1101-W-TACA not shown Top(1251 I Bottom(15.) I Cement Block I Icmu_Pier Omitted I Omitted I LFor Clarity j D-Concrete Transverse LFor Clardy I y Connector _ i C-Concrete5lab/ - Footer 72^ 18'&IM Bolts Model # 1101 T "V" Model # 1101 TC "V" Florida approved 4' ground anchors maybe used in all locations except where home manufacturers spea-fications for sidewall straps are in excess of 4,000 lbs. These locations require a 5' anchor. Per Florida code. C = GROUND PAN / CONCRETE FOOTER OR RUNNER D = GROUND PAN / CONCRETE U BRACKETS TRANSVERSE CONNECTOR (connects with grade 5� 1/2 x3" 1/2" carriage bolt and nut) E = TELESCOPING V BRACE TUBE ASSEMBLY (1.5" TUBE BOTTOM AND 1.25' TUBE INSERTjtOR 1 5" BE F="V"BRACEI-BEAM CONNECTOR ASSEMBLY H =TELESCOPING TRANSVERSE ARM ASSEMBLY ti i 1=TRANSVERSE ARM I -BEAM CONNECTOR (connects with grade 5 -1/2' x 2 '1 /2" carriage bolt and nut) J = V PAN BRACKET (connects with grade 5 -1/2"x 2" 1/2" Carriage bolt and nut) 0.. I -Transverse Arm, ]-Beam F- 'V'Brace l-Beam H-Transverse Arm Connectors / Top (1.25) / \ / Bottom (1S") i D - Pan Transverse Connector / Concrete Transverse Bracket C-Ground Pan / Concrete Footer V - Pan V B/ V Bracket Concrete V Bracket E-'V"BraceTube(I.5") — Model # 1101 "V" ` PATENT# 6634150 & OTHER PATENT PENDING Pant 7101 D-CPCA 8 Part t 1101 %V-CPCA not shown Model # 1101 C -V" Page 3 Revision 08/23/1 E U.. qyx v N,o� � �kzo��i-i a .H o OFig r c ca mza a c'mna. n w9> ommOF i \ cw ` dam �Pi Om N} a w - Idv ..N ioz � aom IN iy yizN cag i�i$c zv� xno Nm>nm n Slp vm0 9y(1n 2y N2D �j. Si Cii w V6'Z 1y0oZ WAN _ O��Flo ' b'9ci NONo iR6 Wym 0 ;mac no'c-'o PU5 _ % 'io oo 5 yN00 KNntxl'9 OY $ mmai AN Omf'1 Z T pv Z-�Ai AAN y1nNav lOx % N99m mO A OOT 1_1 jOC Oyp P CND N g Lon 2 m o yva�G 29ViZ moN a mm o�x � ai 99. OQ' N0pmm -. N TD -NnJy m_ spa NOXOZ .nNm�o S ANC y a MWA oP� .�..Kvv �C� ',E c oti o f . gb�s F 6 n >g NYoe ��scy� x ag9 a 9m=> PURFp.ol2� py � o€s [Ei FieARAo� egg_m�ZON'. >�inmYni�N n+�i n-nN�emm�a'` i��NzF^S m3�,N<g mar'"im�� .oynY noR c0 bil fm vo �3 a x pt _�..Z. y. m > _ om uj c o ji. mo yz _ \' Nor £ - Ai a 'Fpp ¢ g in i a .4 es �� s CENTRAL ,�' � HOMES+�..r.mer�r+a.o.swero.wrs� nmama.cme=maieenwww.wm. b�P•�. Mlb�tltlrytaN�'v YL•la .w. wOHrs weseaveo. un m:ouazne 4 • VERTICAL VINYL SKIRTING C components S installation L I : -MP BACK dIT-TAG5iE0 WITH 1r%ew 5CRGwS 16"APAaT 1 Soars iwro -rap g —'�'� M1OE9 SCREWS AWO PANEL QvTz 1 VF_rITEn pAr;,�1 SECuk6A eP UEwT1LArbn/ �p04QJ- AND .r BdTTOM RA14 YYl VV 1J4cN SLRcws 'ALL PANELS W., oL -- A46 ACCE+6�Ba RETroVING' oP 7-00MT 4%In PLiLLMG 'Y VP ON PANEL! f' I• B OT�O�1n ACID ' `•+� ATTACHED— � s•:,'ti YJ 1T% ROVIUb 7incr QgWANI2EG_NA1L.19'!OG (IF SOIL IS 5ANO4'T11EAI .f I 02102/2018