Loading...
HomeMy WebLinkAboutPODUCT APPROVAL21,13/2018 Florida Building Code Online n• r O /° A t BCIS Home I Login I User Registration I Hot Topics Submit Surcharge I stats & Facts I PublicaUons I PEC staff BCC ji AT4 I1 r mks I search Florida /� q o(� BIVYIVCLJ ei L:r Product Approval FILE--C®�v _ Crt,.h�cie-County I�ke;-arc_ p P USER: Public User 1 C !� APp;gra ffi > Productor Aellicalbn Search > Agpliration Us[ > Application Detail ProducLA�.V rovvaaall 1M'en1u FL # (rj I<y�%C"'I t 3-D4WI FL20378-RL Application Type Revision Code Version 2017 Application Status Approved RECEIVED MAR 21 2019 ST. Lucie County, Permitting Comments Archived [J Product Manufacturer Extreme Metal Fabricators, LLC Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 flvalidation@yahoo.com Authorized Signature Richard McKuhen flvalidation@yahoo.com Technical Representative Richard McKuhen Address/Phone/Email 2160 SW Poma Drive Palm City, FL 34990 (772)872-8034 richard@emfab.net Quality Assurance Representative REVIEWED FOR Address/Phone/Email CODE` COMPLIANCE Category Roofing ST. LUCIE COUNTY Subcategory Metal Roofing BOCC Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer .: Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the LOCKE BOWDEN Evaluation Report Florida License PE-49704 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/22/2024 Validated By Zachary R. Priest, P.E. Certificate of Independence ?+ Validation Checklist - Hardcopy Received LF 2037g_Rj__CQ3_FL 20378.1 NAILSTRIP 1.0 032 ALUM sss.odf Referenced Standard and Year (of Standard) Standard Year TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code htips:/Avww.floridabuilding.org/pr/pr_app_d8.aspx?pamm=wGEVXQwtDqua%2flMZ8n5CNV4ZYkew5Zoa%2fEa/o2fovztglbhDVU2dJO4TAA%3d%3d 114 2/43/2018 Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval - --Date Approved Method I Option D 08/18/2017 12/18/2017 10/17/2017 - 12/1912017-- — Summary of Products FL # Model, Number or Name Description 20378.1 01 - "1" Nailstrip" 0.032" Aluminum Standing Seam roof panel, 12" wide, mechanically attached to 15/32" plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 RI AFL 20378.1 NAILSTRIP 1 0 0,- 32 Approved for use outside HVHZ: Yes ALUM sss.odf Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's Installation FL20378_Rl A_FL 20378.1 NAILSTRIP 1.0-032 Instructions. ALLIM -sss.odf Created by Independent Third Party: Yes 20378.2 02 - "1" Nailstrip" 26-gauge Steel Standing Seam roof panel, 16" wide, mechanically attached to 15/32" plywood or Wood Deck with fasteners and adhesive. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 RI U_FL 20378.2 Extreme Metal Fabricators 26GA NAIL STRIP 1.0.pdf Approved for use outside HVHZ: Yes Impact Resistant: No Verified By: Locke Bowden, P.E. 49704 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's Installation FL20378 RI AE_FL 20378.2 Extreme Metal Fabricators 26GA NAIL STRIP 1.0.odf Instructions. Created by Independent Third Party: Yes 20378.3 03 - "1.75 Snap Lock" 0.032" Aluminum Standing Seam roof panel, 18" wide, mechanically attached to 15/32" plywood or Wood Deck with panel clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 RLLL-FL 20378.3 SNAP LOCK ALUM 1.75-ssr.12df Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378_g1_6E_FL 20378.3 SNAP LOCK ALUM 1.75-ssr.pdf Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. 20378.4 04 - "1.75" Snap Lock" 24-gauge Steel Standing Seam roof panel, 18" wide, mechanically attached to 15/32" plywood or Wood Deck with panel clips and fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378_U-11_FL 20378.4 1.75 SNAP LOCK 24GA-ssr.odf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL2037 _RL_6E_F1_ 20378.4 1.75 SNAP LOCK 24GA-ssr.odf Created by Independent Third Party: Yes Conditions of Use. Refer to manufacturer's installation Instructions. 20378.5 05 - "Rib Panel" 29-gauge Steel exposed fastener roof panel, 36" wide, mechanically attached to 15/32" plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No �0 7$_RT_U_FL 20378.5 RIB 29GA ssr.odf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378 R1.6f-FL 20378.5 RIB 29GA ssr.odf Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. httpsJAvww.floridabuilding.org/pr/pr app dl1.aspx?param-wGEVXQwIDqua%2flMZ8n5CNV4ZYkewSZoa%2fE%2fov tglbhDVU2dJO4TAA%3d%3d 2/4 P751cfYbi1;i Florida Building Code Online 20378.6 06 - "5V Crimp" 26-gauge Steel exposed fastener roof panel, 24" wide, mechanically attached to 15/32" Plywood or Wood Deck w/fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No LF 2037g=1LFL 20378.E 5V rim _ ss. d Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for Method 1 and Method 2 FL20378_R1ARFL 20378.E V Crim _ s-5 f fastening_ Limitations and Conditions of Use. Refer to _ _Created by Independent Third Party: Yes manufacturer's installation instructions. 20378.7 07 - "1.5 Standing Seam" 24-gauge Steel Standing Seam roof panel, 16" wide, mechanically attached to 15/32" plywood or Wood Deck with • panel clips, fasteners and adhesive Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 RS_LFL 20378,7 JM STANDING SEAM sair pdf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378=1AE FL 20378.7 JM STANDING SEAM ssr.odf Created by Independent Third Party: Yes Conditions of Use. Refer to manufacturer's installation instructions. 20378.8 08 - "Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to 15/32" plywood or Wood Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378_R3_[L FL 20378.8_NORDMAN TILE 24GA ssr.Ddf Verified By: Locke Bowden, P.E. 49704 Approved for use outside HVHZ: Yes Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL2�7B_RS_AE FL 20378.8 NORDMAN TILE 24GA sr d Created by Independent Third Party: Yes Conditions of Use. Refer to manufacturer's installation instructions. 20378.9 09 - "Nordman Tile" 24-gauge Steel metal roof tile panel mechanically attached to Steel Deck with fasteners Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 RL11_FL 20378.9 Nordman Tile Details-ssr.odf Verified By: James L. Buckner, P.E. @ CBUCK Engineering P.E. Approved for use outside HVHZ: Yes Impact Resistant: No #31242 Design Pressure: +N/A/ -Table A Created by Independent Third Party: Yes Other: Refer to evaluation report for Limitations and Evaluation Reports Conditions of Use. Refer to manufacturer's installation L2F03Z_g1 AE FL 20378.9 Nordman Tile Details-ssr.pd instructions. Created by Independent Third Party: Yes 20378.10 10 - "Nordman Tile" 0.032" Aluminum metal roof tile panel mechanically attached to 15/32" plywood or Wood Deck with fasteners. Limits of Use Installation Instructions Approved for use in HVHZ: No FL20378 RS LFL 20378.10 NORD TILT .032 ALUM-ssr.pdf Approved for use outside HVHZ: Yes Verified By: Locke Bowden, P.E. 49704 Impact Resistant: No Created by Independent Third Party: Yes Design Pressure: +N/A/ -Table A Evaluation Reports Other: Refer to evaluation report for Limitations and FL20378 gL.ARFL 20378.10 NORD TILT .032 ALUM-ssr.(Ldf Conditions of Use. Refer to manufacturer's installation Created by Independent Third Party: Yes instructions. Hack Next Contact U :: 2601 Blalr Stone Road, Tallahassee FL 32399 Phone: 850-487-1824 The state of Honda Is an ANEED employe, CEO yyht 2007-2013 State of norida.:: Peary Statement :: Accessibility Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your a -mall address released In response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by phone or by taditional mail. If you have any questions, please contact 850.07.1395. *Pursuant to section 455.275(l), Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here . Product Approval Accepts: fftal ®" ® 61g M "SCCUrityM=ETR1CS- https:lhvww.floridabuilding.org/prlpr app_dtl.aspx?param= GEVXQwtDqua4/o2flMZ8n5CNV4ZYkew5Zoa%2fE%2fov tglbhDVU2dJO4TAA%3d4/o3d 314 ;Product Report _ - IVlanufacturer: Extreme Metal Fabriea'tors, LLCji 2160 SW Poma Drive Palm City, FL 34990 ( -772) 872-8034 Compliant with Florida Building Code 2017 (61h ed.) Compliant with Florida Product Approval Rule # 61G20-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Metal Roofing Panel Corrosion Resistant FBC Sec. 1507.4.3 Yield strength:40ksi Steel Attached to min.15/32" plywood or Wood Deck w/ min. Attached 24" OA2 specific gravity with screws. 24" Coverage Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec. 1506, 1507 Fastener for Method 1 Attachment # 9-15 x 1"Hex Head w/EPDM Bonded Steel Washer to penetrate 3/16" thru wood decking Fastener for Method 2 Attachment # 9-15 x 1" Hex Head w/EPDM Bonded Steel Washer to penetrate 3/16" thru 15/32"min. plywood deck or 5/8" into wood plank Underlayment: To be compliant with FBC Sec.1507.1.1 Slope: Shall be in compliance with FBC Sec. 1507. DESIGN PRESSURE* -85 PSF1 -114.25 PSF IMETHOD I IN IDa PEAKS ROW SPACING 12" O.C. 12" O.C. METHOD 21N PANEL FlA75 FASTENER SPACING 12" O.C. 12" O.C. 'SEE INSTALL DRAWINGS FASTENER SIZE: #9 #9 *ALLOWABLE DESIGN PRESSURE MARGIN OF 2 TO 1 Reference Data: HURRICANE TEST LAB #TST ID: 2527 TAS 125-03 Test # 0223-0307-01; METHOD i (UL 1897-041) TAS-225.03 Test # 0223-0517-06, METHOD 2 EQUIVALENCY UL 1997-04 IS EQUIVALENT TO UL 1897-12 TEST STANDARD • DESIGN PRESSURE SAFETY MARIGIN 2:1 Certificate of Independence: Locke Bowden, P.E. does not have, not will acquire a financial Interest In any company manufacturing or distributin prodL under this evaluation. ��, TTI t1L}}� 11 �¢rrrrr,, Locke Bowden, P.E. is not owned, operated, or controlled by any company, manufacturer, or distributI4g FbdQ2tAAdliAtl report i'4 J Compliance Statement: These products herein evaluated have demonstrated compliance with the Florida Building Code 2017 61h ed., with referenced documents submitted. Limitations: 1. Underlayment to be compliance with current Florida Building Code 2017 6u ed-, Section 1507.1.1 2. Products are compliant for State of Florida product approval per Rule 61G20-3 3. Compliance -Method: 1-D ---- - --- 4. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 5. All support framing compliant w/ Florida Building Code 2017, Chapters 22 for Steel, 23 for Wood and 16 for Structural Loading. Design of support and attachment to the framing is outside the scope of this evaluation. 6. Rule 61G20-3 allows for engineering analysis by registered/licensed others for "project specific approval' by local authorities, authorized by the code, and is the responsibility of others. 7. This report does not imply warranty, installation, recommended product use outside of this report. oo9f0flig F9rYRI04 Q - Wood VI daVc C�elencR _ -1632" or greater Plywood, or - Wood plank SCANNED-- i€ BY % "m St. Lucie County BCIS Home I tngM User Registration I Hot Toplm I submit Surcharrggee I Slats&Facts I Publiratlons j Contact Us ( acts Site Map Links Search ——_�3Yn[r�yo�ridaPrADUSIM-ftblic ProdU.. Approval _ _■ i L�e Vr/® PY _ 6MIr 1RNvm EMggCt Apnmvai Menu > Product or AoS iratian Search > @/Ig''yliA/wtion Lis[ > Application Detail FL #��Q �� ! O3�O Ta7 y FLI1602-R7 Application Type Revision Code Version 2017 Application Status Approved Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature v RECEIVED MAR 21 2019 PT, 16MOD cQNnEY. PPrIY1IE€m Owens Corning Roofing and Asphalt, LLC One Owens Corning Parkway Toledo, OH 43645 (740) 321-6345 Greg.Keeler@owenscoming.com Keeler Greg Greg.Keeler@owenscoming.com Technical Representative Greg Keeler Address/Phone/Email 2790 Columbus Road Granville, OH 43023 (740) 321-6345 greg.keeler@owenscorning.com Quality Assurance Representative REVIEWED FOR Address/Phone/Email CODE COMPLIANCE Category Roofing ST. LUCIE COUNTY Subcategory Underlayments ®OCC Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer .J Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity Quality Assurance Contract Expiration Date 09/30/2019 Validated By ]ohn W. Knezevich, PE `.f Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL11602 R7 COI 2018 01 COI NIEMINEN.odf Standard ASTM D1970 ASTM D226 (physicals) ASTM D4798 FRSA/TR1 April 2012 TAS 117(B) Year 2015 2009 2011 2012 1995 Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/16/2018 10/08/2018 08/23/2018 10/18/2018 FL 7f Model, Number or Name Description 11602.1 Titanium Roof Underlayments Synthetic sheet -type roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No F1_31602 R7 II 2018 09 FINAL2 ER OWENS Approved for use outside HVHZ: Yes CORNING FL11602-R7.odf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-45 Created by Independent Third Party: Yes Other: 1.) The design pressure noted herein pertains to use of Evaluation Reports a specific underlayment system beneath foam -on the sytsems. FL11602 R7 AE 2018 09 FINAL2 ER OWENS Refer to ER Section 5.6.3 for details. 2.)'Refer to ER Sections 5 CORNING FLI1602-R7.Ddf and 6 for other Limits of Use. Created by Independent Third Party: Yes Back Neat contact Us :: 2601 Blair Stone Road, Tallahassee R 32399 Phone: B50-487-1824 Tie State of Florida Is an AA/EEO employer..CWjight 20D7-20I3 State of Florida.:: Pdvacv Statement :: AccessibTUy, Statement :: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released in response fn a public.mmrds request, do not send electronic mall M this entity. Instead, contact the oFce by phone or by traditional mail. If you have any questions, please contaR 650.487.1395. *Pursuant to Section 455.275(1), Podtla Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address H they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please didc here,. Product Approval Accepts: M I M Credit Card Safe