Loading...
HomeMy WebLinkAboutCERTIFICATION DESIGN LOAD COMPLIANCEPlanning & Development Services Department Building & Code Regula ' I``��'sio } 2300 Virginia Avenue, Fort Pierce, F7(46 Certification for Design Load Compliance . Py Project Name: MA/si-41i lzts/d[nrL Project Address: Lo} 95 TrtasuK Coast A4rPcrlc - SW NAJIon ��, Si. f ,c;t C.,,3-y,FC Permit #: Construction Type: This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) SCANNED o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. BY St. Lucie County ' Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Code Fifth Edition with 20f_1_Supplements using ASCE 7-10 2. Structure Designed as (check one): )_Enclosed _Partially Enclosed _Open 3. Risk Category: _I X 11 _III _ IV Exposure Category: _B JS_C _D 4. Design Wind Velocity f 7 o mph _ASO X LRFD End Zone Width: Y. 8 ft S. Mean Roof Height 27- io" ft Roof Pitch: :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: y3.o Zone 2: 50.3 Zone 3: 56, 3 Zone 4: q&.7 Zone 5: 574 Garage: l &.le 7. Design Loads: Floor: (05 PSF Roof/Dead: Z i� PSF Roof/Live: 3 0 Balcony: 0_PSF Dock: tJ A PSF Deck: !00 PSF Stairs: o PSF Fence: /J A PSF Railings: 50 PSF 8. Were Shear Walls Considered For Structure? X' Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? l4 Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 05706 PSF Soil Test Reports Submitted? X Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: SIS Signature, Date, and Seal Revised 07/25/2014 lo185-6 Print Name Cert # & Co. Cert Auth. (En.' XOe ��< nF Cl.�.ti�Iiun1 [ 5'•-t. 2Lo PRI r 6[sc L. C- rd<ns .AC 33y17 Company Name & Address