HomeMy WebLinkAboutCERTIFICATION DESIGN LOAD COMPLIANCEPlanning & Development Services Department
Building & Code Regula ' I``��'sio
} 2300 Virginia Avenue, Fort Pierce, F7(46
Certification for Design Load Compliance . Py
Project Name: MA/si-41i lzts/d[nrL
Project Address: Lo} 95 TrtasuK Coast A4rPcrlc - SW NAJIon ��, Si. f ,c;t C.,,3-y,FC
Permit #:
Construction Type:
This certification must be completed, signed, and sealed by the design professional of record.
Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family) SCANNED
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
BY
St. Lucie County
' Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida Code Fifth Edition with 20f_1_Supplements using ASCE 7-10
2. Structure Designed as (check one): )_Enclosed _Partially Enclosed _Open
3. Risk Category: _I X 11 _III _ IV Exposure Category: _B JS_C _D
4. Design Wind Velocity f 7 o mph _ASO X LRFD End Zone Width: Y. 8 ft
S. Mean Roof Height 27- io" ft Roof Pitch: :12 Parapet: ft
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: y3.o Zone 2: 50.3 Zone 3: 56, 3 Zone 4: q&.7 Zone 5: 574 Garage: l &.le
7. Design Loads: Floor: (05 PSF Roof/Dead: Z i� PSF Roof/Live: 3 0 Balcony: 0_PSF
Dock: tJ A PSF Deck: !00 PSF Stairs: o PSF Fence: /J A PSF Railings: 50 PSF
8. Were Shear Walls Considered For Structure? X' Yes _Not Applicable Explain Why Not:
9. Is A Continuous Load Path Provided? l4 Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 05706 PSF Soil Test Reports Submitted? X Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
SIS
Signature, Date, and Seal
Revised 07/25/2014
lo185-6
Print Name Cert # & Co. Cert Auth.
(En.'
XOe ��< nF Cl.�.ti�Iiun1 [ 5'•-t. 2Lo
PRI r 6[sc L. C- rd<ns .AC 33y17
Company Name & Address