Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FILE COPY FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name:. MARSHALL RESIDENCE Builder Name: PACE 2000, INC. SCANNED Street: NAVION DRIVE Permit Office. ST LUCIE COUNTY BY City, State, Zip: PORT ST LUCIE , FL, Permit Number. Owner. Jurisdiction: ST LUCIE COUNTY St. Lucie County Design Location: FL, Fort Pierce County. St. Lucie (Florida Climate Zone 2 ) 1. New construction or e)asting New (From Plans) 9. Wall Types (4153.0 sgfL) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block- E# Insul, Erderior R=4.1 3653.00 ft' 3. Number of units, it multiple family 1 b. Frame - Wood, Adjacent R=11.0 500.00 fP c. N/A R= ft' 4. Number of Bedrooms 4 d. N/A R= ft, 5. Is this aworst case? No 10. Ceiling Types (3926.0 sgfL) Insulation Area a. Roof Deck (Unvented) R=20.0 3926.00 ft' 6. Conditioned floor area above grade (fP) 3926 b. N/A R= ft' Conditioned floor area below grade (tP) 0 R_ : 17 Ducts R fN 7. W indaws (490.3 sqf .) Description Area a: Sup: Attic, Rat Attic, AH: Attic 6 200 a. U-Factor. Sgl, U=0.65 490.26 fP b. Sup: Attic, Ret Attic, AH: Attic 6 130 SHGC: SHGC=0.25 b. U-Factor. N/A ft' 12. Cooling systems kBtulhr Efficiency SHGC: a. Central Unit 48.0 SEER:16.00 c. U-Factor. N/A ft' b. Central Unit 18.8 SEER:16.00 SHGC: 13. Heating systems kBtuthr Efficiency d. U-Factor. N/A ft' a Electric Strip Heat 34.0 COP:1.00 SHGC: b. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 1.500 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems .8. Floor Types (3926.0 sgft.) insulation Area a. Natural Gas Cap: 50 gallons a. Slab -On -Grade Edge insulation R=0.0 2754.00 fP b. Conservation features EF: 0.600 b. Raised Floor R=19.0 1172.00 ft' None c. N/A. R= fP 15. Credits None Glass/Floor Area: 0.125 Total Proposed Modified Loads: 127.39 PASS 'total Baseline Loads: 131.34 I hereby certify that the plans and specifications covered by Review of the plans and. F-fliE STg7 this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance with the Florida Energy Code. F rrrrrr PREPA D Y• Before construction is completed' w O DATE: this building will be inspected for q compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. !) with the Florida Energy Co COD WO OWNER/AGENT BUILDING OFFICIAL: DATE: 3-- .9- DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 10/19/2018 1:27 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 9 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Tift MARSHALL RESIDENCE Bedrooms: 4 Address Type: Street Address Building Type: User Conditioned Area 3926 Lot# Owner Name: Total Stories: 1 Block/Subdivision: #of Units: 1 Worst Case: No PlatBook Builder Name: PACE 2000, INC. Rotate Angle: 0 Street. NAVION DRIVE - Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. St Lucie Jurisdiction: ST LUCIE COUNTY Whole House For: No City, State, Zip: PORT ST LUCIE. Family Type: Single-family FL New/E)dsting: New (From Plans) Comment CLIMATE Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 2 1172, 10548 2 AHU 1 2754 38028 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infit ID Finished Cooled Heated 1 BEDROOM 2 233 2330 No 0 1 1 Yes Yes Yes 2 CLST2 18 180 No 0 1 Yes Yes Yes 3 BATH 70 700 No 0 1 Yes Yes Yes 4 LAUNDRY 90 900 No 0 1 No Yes Yes 5 HALL 40 400 No 0 1 No Yes Yes 6 GREAT ROOM 628 13816 No 0 1 Yes Yes Yes 7 KITCHEN 230 2300 Yes 0 1 No Yes Yes 8 PANTRY 25 250 No 0 1 No Yes Yes 9 DINING ROOM 224• 2240 No 0 1 Yes Yes Yes 10 FOYER 176 3696 No 0 1 Yes Yes Yes 11 POWDER 36 360 No 0 1 No Yes Yes 12 HALLWAY 12 120 No 0 1 No Yes Yes 13 OFFICE 222 2664 No 0 1 Yes Yes Yes 14 M WIC 80 800 No 0 1 Yes Yes Yes 15 M BATH 170 1870 No 0 1 Yes Yes Yes 16 M TOILET 24 240 No 0 1 No Yes Yes 17 HIS WIC 42 420 No 0 1 Yes Yes Yes 18 STORAGE 32 320 No 0 1 No Yes Yes 19 MASTER BEDROO 402 4422 No 0 1 1 Yes Yes Yes 20 STAIRS UP 64 576 No 0 1 Yes Yes Yes 21 'BALCONY 325 2925 No 0 1 Yes Yes Yes 10/19120181:27 PM EnergyGaugeO USA Section R405A.1 Compliant Software Page 2 of 9 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 22 CRAFT ROOM 164 1476 No 0 1 Yes Yes Yes 23 CRAFTWIC 54 486 No 0 1 Yes Yes Yes 24 WIC 4 30 270 No 0 1 Yes Yes Yes 25 BEDROOM 4 156 1404 No 0 1 1 Yes Yes Yes 26 BATH 3 126 1134 No 0 1 Yes Yes Yes 27 TOILET 15 135 No 0 1 No Yes Yes 28 WIC 25 225 No 0 1 No Yes Yes 29 BEDROOM 3 213 1917 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space _ Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge insulation BEDROOM 2 31 It 0 233 ft' — 1 0 0 2SIab-On-Grade Edge Insulation CLST 2 2 ft '0 18 H' — 1 0 0 3 Slab -On -Grade Edge Insulation BATH 2 loft 0 70 ft' — 1 0 0 4 Slab -On -Grade Edge Insulation LAUNDRY 111 0 90 fl' 1 0 0 5 Slab -On -Grade Edge Insulation HALL 1 ft 0 40 ft' — 1 0 0 6 Slab -On -Grade Edge Insulation GREAT ROOM 31 It 0 628 fl' — 1 0 0 7SIatrOn-Grade Edge Insulation KITCHEN lit 0 230 fN 1 0 0 8 Slab -On -Grade Edge Insulation PANTRY 1 ft 0 25112 _ 1 0 0 9 Slab -On -Grade Edge Insulation DINING ROOM 18 ft -0 224 ft' 1 0 0 10SIab-On•Grade Edge Insulation FOYER 8 ft 0 176 ft- — 1 0 0 11SIab-On-Grade Edge Insulation POWDER 1 ft 0 36 fN — 1 0 0 1251ab-On-Grade Edge Insulation HALLWAY 1ft 0 12 ft' — 1 0 0 13SIab-On-Grade Edge Insulation OFFICE 25.3 It 0 222 ft' — 1 0 0 14SIab-On-Gmde Edge Insulation M WIC 18 ft 0 60 fF — 1 0 0 16SIab-On-Grade Edge Insulation M BATH lift 0 170 ft' — 1 0 0 16SIab-On-Grade Edge Insulation M TOILET 1 ft 0 24 ft- — 1 0 0 17SIab-On-Grade Edge Insulation HIS WIC 7 ft 0 42 fN — 1 0 0 18SIab-On-Grade Edge Insulation STORAGE 1 ft 0 32 fN — 1 0 0 19SIab-On-Grade Edge Insulation MASTER BEDRO 39 ft 0 402 ft' — 1 0 0 20Ralsed Fluor STAIRS UP — — 64 ft' 19 1 0 0 21Ralsed Floor BALCONY _ 325 ft' 19 1 0 0 10119/20181:27 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 9 - FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 22Raised Floor CRAFT ROOM — — 164 ft- 19 1 0 0 23Raised Floor CRAFT WIC _ — 54 ft' 19. 1 0 0 24Ralsed Floor WIC4 30 ft- 19 1 0 0 25Ralsed Floor BEDROOM 4 — — 156 ft' 19 1 0 0 2ERaised Floor BATH 3 _ _ 126 ft' 19 1 0 0 27Ralsed Floor TOILET — 15 fP 19 1 0 0 "28Raised Floor WIG 3 __ 25 ft' 19 1 0 0 29Raised Floor BEDROOM 3 __ _ 213 ft2 19 1 0 0 ROOF / Roof Gable Roof Solar SA Emig Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 4391 ft' 0 ft' Medium 0.6 No 0.9 No 20 26.6 ATTIC # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 3926 ft' N N 10/19/2018 1:27 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 9 CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 2 20 Blown 233 ft' 0.1 Wood 2 Under Attic (Unvented) CLST 2 20 Blown 18 ft' 0.1 Wood 3 Under Attic (Unvented) BATH 2 20 Blown 70 ft- 0.1 Wood 4 Under Attic(Unvented) LAUNDRY 20 Blown 90 iP 0.1 Wood 5 Under Attic(Unvented) HALL 20 Blown 40 it- 0.1 Wood 6 Under Attic (Unvented) GREAT ROOM 20 Blown 628 ft- 0.1 Wood 7 Under Attic (Unvented) KITCHEN 20 Blown 230 ft' 0.1 Wood 8 Under Attic (Unvented) PANTRY 20 Blown 25 ft- 0.1 Wood 9 Under Attic(Unvented) DINING ROOM 20 Blown 224 ft- 0.1 Wood 10 Under Attic (Unvented) FOYER 20 Blown 176 ft- 0.1 Wood 11 Under Attic (Unvented) POWDER 20 Blown 36 ft' 0.1 Wood 12 Under Attic (Unvented) HALLWAY 20 Blown 12 fP 0.1 Wood 13 Under Attic(Unvented) OFFICE 20 Blown 222 it- 0.1 Wood 14 Under Attic (Unvented) MWIC 20 Blown 80 ft' 0.1 Wood 15 Under Attic (Unvented) MBATH 20 Blown 170 fP 0.1 Wood 16 Under Attic(Unvented) MTOILET 20 Blown 24 tt' 0.1 Wood 17 Under Attic (Unvented) HISWIC 20 Blown 42 ft' 0.1 Wood 18 Under Attic (Unvented) STORAGE 20 Blown 32 iP 0.1 Wood 19 Under Attic (Unvented) MASTER BEDRO 20 Blown 402 ft' 0.1 Wood 20 Under Attic (Unvented) STAIRS UP 20 Blown 64 it- 0.1 Wood 21 Under Attic (Unvented) BALCONY 20 Blown 325 ft' 0.1 Wood 22 Under Attic(Unvented) CRAFT ROOM 20 Blown 164 iP 0.1 Wood 23 Under Attic (Unvented) CRAFT WIC 20 Blown 54 fP 0.1 Wood 24 Under Attic (Unvented) WIC 20 Blown 30 fP 0.1 Wood 25 Under Attic (Unvented) BEDROOM 20 Blown 156 R2 0.1 Wood 26 Under Attic (Unvented) BATH 20 Blown 126 ft' 0.1 Word 27 Under Attic (Unvented) TOILET 20 Blown 15 ft' 0.1 Wood 28 .Under Attic (Unvented) WIC3 20 Blom 25ft' 0.1 Wood 29 UnderAtfic (Unvented) BEDROOM 3 20 Blown 213 fP 0.1 Wood WALLS Natacent Space Cavity Width Height Sheathing Framing Solar Below o 1 N Exterior Concrete Block -Ext lnsSEDROOM2 4.1 18: 0 10 0 180.0 fF 0 0 0.6 0 - 2 W Exterior Concrete Block -Ext lnsZEDROOM2 4.1 13 0 10 0 130.0 f1' 0 .0 0.6 0 3 N Exterior Concrete Block - ExtInsul CLST 2 4.1 2 0 10. 0 20.0 fN 0. 0 0.6 0 _4 W Exterior Concrete Block -Ext lnsul BATH 4.1 10 0 10 0 100.0 fN 0 0 0.6 0 5 S Garage Frame- Wood BATH 2 11 7 0 10 0 70.0 fP 0 0.25 0.6 0 6 S Garage Frame -Wood LAUNDRY 11 9 0 10 0 90.0 fP 0 026 0.6 0 7 S Garage Frame - Wood HALL 11 4 0 10 0 40.0 W 0 0.25 0.6 0 8 N Exterior Concrete Block -Ext lnsGREAT ROO 4.1 31 0 22 0 682.0 ft- 0 0 0.6 0 9 W Garage Frame -Wood KITCHEN 11 5 0 10 0 50.0 it' 0 0.25 0.6 0 10 S Garage Frame -Wood PANTRY 11 4 0 10 0 40.0 ft- 0 025 0.6 0 _ 11 W Garage Frame- Wood PANTRY 11 5 0 10 0 50.0 R' 0 025 0.6 0 10/19/2018 1:27 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 5 of 9 - FORM R405-2017 INPUT SUMMARY C4IFCKI IRT RFPART - WALLS - - - --- - - - Adjacent Space Cavity Width Height Sheathing Framing Solar Belau _12 E Exterior Concrete Block- Ext lnsdOINING ROO 4.1 4 0 10 0 40.0 ft' 0 0 0.6 0 13 S Exterior Concrete Block- Ext Insd5INING ROO 4.1 14 0 10 0 140.0 ft' 0 0 0.6 0 _14 W Garage Frame -Wood DINING ROO 11 16 0 10 0 160.0 ft' 0 025 0.6 0 _ 15 S Exterior Concrete Block- Ext Insul FOYER 4.1 8 0 21 0 168.0 ft' 0 0 0.6 0 _ 16 E Exterior Concrete Block- Ext Insul OFFICE 4.1 3 0 12 0 36.0 ft. 0 0 0.6 0 _17 BE Exterior Concrete Block -Ext Insul OFFICE 4.1 5 8 12 0 68.0 to 0 0 0.6 0 _18 S Exterior Concrete Block -Ext Insul OFFICE 4.1 6 0 12 0 72.0 it' 0 0 0.6 0 _ 19 SW Exterior Concrete Block- Ext Insul OFFICE 4.1 5 8 12 0 68.0 ft' 0 0 0.6 0 _20 W Exterior Concrete Block -Ext Insul OFFICE 4.1 5 0 12 0 60.0 ft' 0 0 0.6 0 _21 E Exterior Concrete Block- Ext Insul M W IC 4.1 10 0 10. 0 100.0 ft' 0 0 0.6 0 22 S Exterior Concrete Block-Ext Insul MWIC 4.1 8 0 10 0 80.0 fP 0 0 0.6 0 _ 23 E Exterior Concrete Block - E d Insul M BATH 4.1 9 0 11 0 99.0 ft. 0 0 0.6 0 24 S Exterior Concrete Block - 6d Insul M BATH 4.1 2 0 11 0 22.0 ft' 0 0 0.6 0 _ 25 E Exterior Concrete Block- Ext Insul HIS WIC 4.1 7 0 10. 0 70.0 W 0 0 0.6 0 26 N Exterior Concrete Block -Ext IostMASTER BE 4.1 18 0 11 0 198.0 to 0 0 0.6 0 27 E Exterior Concrete Block - Ext lnstMASTER BE 4.1 21 0 11 0 231.0 ft' 0 0 0.6 0 28 E Exterior Concrete Block- Ext InsuSTAIRS UP 4.1 8 0 9 0 720 ft' 0 0 0.6 0 29 S Exterior Concrete Block - Ext InsuSTAIRS UP 4.1 8 0 9 0 720 ft' 0 0 0.6 0 30 E Exterior Concrete Block- Ext InsuIBALCONY 4.1 4 0 9 0 36.0 ft' 0 0 0.6 0 31 W Exterior Concrete Block - Ext InsuIBALCONY 4.1 4 0 9 0 36.0 ft' 0 0 0.6 0 32 N Exterior Concrete Block- Get lnsi6RAFl ROO 4.1 12 0 9 0 '108.0 ft' 0 0 0.6 0 _ 33 N Exterior -Concrete Block - Ext Insr6RAFT WIC 4.1 6 0 9 0 64.0 ft' 0 0 0.6 0 34 W Exterior Concrete Block - Ext lnstXRAFr WIC 4.1 9 0 9 0 81.0 ft3 0 0 0.6 0 _ 35 W Exterior Concrete Block - Ext Insul WIC 4 4.1 5 0 9 0 45.0 ft' 0 0 0.6 0 36 S Exterior Concrete Block- Ext InstBEDROOM 4 4.1 12 0 9- 0 108.0 IF 0 0 0.6 0 37 W Exterior Concrete Block -Ext lnsiBEDROOM4 4.1 13 0 9 0 117.0ft' 0 0 0.6 0 _ 38 S Exterior Concrete Block - Ext Insul BATH 3 4.1 11 0 9 0 99.0 ft' 0 0 0.6 0 _ 39 E Exterior Concrete Block- Ext InstSEDROOM 3 4.1 3 0 9 0 27.0 ft' 0 0 0.6 0 40 S Exterior Concrete Block- Ext InstSEDROOM 3 4.1 13 0 9 0 117.0 ft' 0 0 0.6 0 41 W Exterior Concrete Block- Ext InstBEDROOM 3 4.1 13 0 9 0 117.0 fF 0 0 0.6 0 DOORS # Omt Door Type Space Stones U-Value Width Height Area Ft In Ft In 1 E Insulated BALCONY None .39 2 8 6 8 17.8 ft' 10/19/2018 1:27 PM EnergyGauge® USA Section R405A.1 Compliant Software Page 6 of 9 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WINDOWS Orientation shown Is the entered, Proposed orientation. _ / Wall Overhang V # Oral ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 N 1 Metal W*E Single Yes 0.65 0.25 N 24.0 ft' 1 It 6 in 1 1141n None None 2 W 4 Metal Low-E Single Yes 0.65 0.25 N 8.0 ft' 1 ft 61n 1 It 41n None None 3 N 8 Metal Low-E Single Yes 0.65 025 N 48.0 ft- 1 ft 6 in 1 ft 4 in None None 4 N 8 Metal Low-E Single Yes 0.65 025 N 48.0 ft 1 ft 61n 1 It 4 in None None 5 S 13 Metal Low-E Single Yes 0.65 0.25 N 16.0 fP 1 It 6 in 1 ft 4 in None None 6 S 13 Metal Low-E Single Yes 0.65 0.25 N 11.0 ft- 1 ft 6 in 1 It 4 in None None 7 S 13 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft- 1 ft 6 in 1 ft 4 in None None 8 S 13 Metal Low-E Single Yes 0.65 0.25 N 18.0 ft- 1 It 6 in 1 It 4 in None None 9 S 15 Metal Low-E Single Yes 0.65 0.25 N 48.0 ft- 1 It 6 in 1 It 41n None None 10 BE 17 Metal Low-E Single Yes 0.65. 0.25 N 5.8 ft- 1 It 6 in 1 ft 4 in None None 11 BE 17 Metal Lowy E Single Yes 0.65 025 N. 17.5 ft- 1 1161n 1 1141n None None 12 S 18 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft- 1 ft 6 in 1 1t 4 in None None 13 S 18 Metal Low-E Single Yes 0.65 0.25 N 18.0 f? 1 ft 61n 1 ft 4 in None None _ 14 SW 19 Metal Low-E Single Yes 0.65 025 N 5.8 ft- 1 ft 61n 1 ff4 in None None 15 SW 19 Metal Low-E Single Yes 0.65 0.25 N 17.5 fP 1 ft 6 in 11114 in None None 16 S 22 Metal Lcw-E Single Yes 0.65 0.26 N 6.0 ft- 1 ft 6 in 1114 in None None 17 E 23 Metal Low-E Single Yes 0.65 0.25 N 16.0 ft- 1 It 6 in 1 It 4 In None None 18 N 26 Metal Low-E Single Yes 0.65 0.25 N 48.0 fN 1 ft 6 in 1 114 in None None 19 E 27 Metal Low-E Single Yes 0.65 0.25 N 12.0 ft' 1 It 6 in 1 ft 4 in None None 20 N 32 Metal Low-E Single Yes 0.65 0.25 N 53.6 IV 1 ft 6 in 1 1141n None None 21 W 37 Metal Low-E Single Yes 0.65 0.25 N 6.0 ft- 1 It 6 in 1 It 4 in None None 22 W 37 Metal Low-E Single Yes 0.65 0.25 N 15.0 ft- 1 ft 6 in 1 It 4 in None None 23 S 40 Metal Low-E Single Yes 0.65 0.25 N 30.0 ft- 1 ft 6 in 1 ft 4 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 864 ft- 864 ft- 26 If 12 It 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .00055 5667.2 311.12 585.11 .4545 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None C0P:1 34 kBtu/hr 2 sys#1 2 Electric Strip Heat/ None COP:1 17 kBW/hr 1 sys#2 10/1912018 1:27 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 7 of 9 FORM R405-2017 INPUT SUMMARY rHFrK1 1ST RFPART COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split SEER: 16 48 kBtuQv 1440 dfm 0.8 2 sys#1 2 Central UniU Split SEER: 16 18.8 kStulhr 564 cfm 0.8 1 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Natural Gas None Garage 0.6 50 gal 62.3 gal 120 deg None 'SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft: DUCTS _ / —Supply— —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6. 200 ft' Attic 20 ft' Default Leakage Attic (Default) c(Default) c 1 1 2 Attic 6 130 ft' Attic 13 W Default Leakage Attic (Default) c(Default) c 2 2 TEMPERATURES Prograrnabie Thermostat: N Ceiling Fans: Cooling t Jan Feb Jan Feb Mar Mar Apr � Apr May � � Jun Jul � � Aug S:p Oct � � jrX'I Dec � Decec VenNov ng ! 1 May Jun Jul Aug Sep Oct [ JX Nov Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 80 80 78 78 78 78 78 78 78 78 Healing(WD) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 65 65 65 65 65 65 65 68 68 68 68 68 PM 68 _ 68 68 68 68 68 68 68 68 68 68 68 10/19/2018 1:27 PM EnergyGauge® USA Section R405.4.1 Compliant Software, Page 8 of 9 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction _ Space Default(81bs/sq.fL 0 fl2 0 ft 0.3 BEDROOM 2 Defauft(8 IbslsgfL ft2 ft 0.3 CLST 2 Default(8 Ibslsq.fL ft' ft 0.3 BATH 2 Default(81bs/sq.fL ft' ft 0.3 LAUNDRY Default(8 lbs/sq.fL ft' ft 0.3 HALL Default(8 lbs/sq.fL ft2 It 0.3 GREAT ROOM Default(8 lbs/sq.fL ft2 It 0.3 KITCHEN Default(8 lbslsq.ft ft' ft 0.3 PANTRY Default(8 lbs/sq.fL ft' It 0.3 DINING ROOM Default(B Ibs/sq.fL fP It 0.3 FOYER Default(81bs/sq.fL W It 0.3 POWDER Default(8 lbs/sq.fL ft2 ft 0.3 HALLWAY Default(8 lbs/sq.fL ft2 ft 0.3 OFFICE Default(B Ibslsq.fL ft2 ft 0.3 M WIC Default(8 lbs/sq.fL ft2 it 0.3 M BATH Default(8 Ibs/sq.fL ft2 It 0.3 M TOILET Default(8 lbs/sq.fL ft' ft 0.3 HISWIC Default(81bs/sq.fL ft. ft 0.3 STORAGE Default(8 lbs/sq.fL ft' It 0.3 MASTER BEDROO Default(B Ibs/sq.ft. ft2 ft 0.3 STAIRS UP Default(8 lbslsq.ft. ft2 It 0.3 BALCONY Default(8 lbslsq.fL. ft2 It 0.3 CRAFT ROOM Default(8 lbs/sq.fL ft2 ft 0.3 CRAFTWIC Default(B lbslsq.fL ft2 ft 0.3 WIC4 Default(81bs/sq.ft. ft' It 0.3 BEDROOM Default(8 Ibs/sq.ft. ft2 it 0.3 BATH 3 Default(8 lbslsq.fL ft2 it 0.3 TOILET Defaulgil Ibs/sq.fL W ft 0.3 WIC3 Default(B lbs/sq.fL . , ft' it 0.3 BEDROOM 3 Name: Signature: QUCF36� Rating Compant: Date: 10119/2018 127 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 9 of 9 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: MARSHALL RESIDENCE Builder Name: PACE 2000, INC. Street NAVION DRIVE Permit Office: ST LUCIE COUNTY City, State, Zip: PORT ST LUCIE, FL, Permit Number. Y Owner: Jurisdiction: ST LUCIE COUNTY w Design Location: FL, Fort Pierce X COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERI General A continuous air barter shall be installed in the building envelope. Mr -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a searing material. Breaks orjoints In the air barrier shag be sealed. Cering/attic The air barrier In any dropped ceilinglsoffd shag be aligned with the insulation and any gaps in the air barrier shall be sealed. The insulation in any dropped ceging/soffit Access openings, drop down stairs or knee wall doors to shall be aligned with the air barrier. unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be sealed. shag be Insulated by completely filing the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall Include the air harder. _ Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing cavity insulation shall be installed to (including above -garage maintain permanent contact with the underside of and cantilevered floors) subfloor decking, or floor framing cavity Insulation shall be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottorr to the top of all perimeter floor framing members. Crawl space walls Exposed earth In unvented crawl spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts In narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filed by insulation that on Installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed fighting Recessed light fixtures Installed In the burring thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut really to fit around wiring or J plumbing in exterior wags, or insulation that on installation readily conforms to available space shag extend behind I in and wiring. Showedtub The air harrier installed at exterior walls adjacent to showers and Exterior wags adjacent to showers and tubs shall be on exterior wall tubs shall separate them from the showers and tubs. insulated. Edectricarlphone box on The air barrier shall be installed behind electrical or communication exterior wags boxes or alr-sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shag be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shag only be sealed sprinklers in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkle later and walls or ceilin s. a In addition Ins ection of I wall hall p og s s be m accoMance wth the provisions of ICC-000. - 10/19/20181:28 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 97 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 3. No. of units (ifmultiple-family)3. 1 c) AHU location AtticJAttic 4. Number of bedrooms 4. 4 5. Is this a worst case? (yes/no) 5. No 6. Conditioned floor area (sq. ft.) 6. 3926 7. Windows, type and area a) U-factor.(weighted average) 7a.. - 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 c) Area 7c. 490.3 8. Skylights a) U-factor.(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 19.0 c) Concrete, raised (R-value) 9c. 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 13. Cooling system: Capacily - 66.8 a) Split system SEER 16.0 b) Single package SEER c) Ground/water source SEER/COP d) Room unit/PTAC EER e) Other 14. Heating system: Capacity 51.0 a) Split system heat pump HSPF b) Single package heat pump HSPF c) Electric resistance COP 1.0 d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF b) Gas fired, natural gas EF 0.60 c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF_ 0 Heat recovery unit HeatRec% g) Other 10B1. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11a. 20.0 b) Cross ventilation No 11b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit 0 Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) In this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: 3-19-19 Address of New Home: NAVION DRIVE City/FL Zp: PORT ST LUCIE. FL 10/19/2018 1:28:11 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 • + wrightsofI Project Summary AHU1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax T72-466-6796 FILE Emaf: OUICKCALCSQAOL.COM Project Information Job: Date: Oct 19, 2018 C B 0 Py For: MARSHALL RESIDENCE PACE 2000, INC. NAVION DRIVE, PORTSf LUCIE, FL SCANNED BY Notes: St. Lucie County D- . Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range Relative humidity M 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 35509 Btuh Structure 26716 Btuh Ducts 9127 Btuh Ducts 8531 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 44636 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 33485 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 5310 Btuh Ducts 3545 Btuh Central vent (0 cfm) 0 Btuh Heatingg Cooling (none) Area (ft� 2754 2754 Equipment latent load 8855 Btuh Volume (W) 44202 44202 Airchanges/hour 0.26 0.14 Equipment Total Load (Sen+Lat) 42341 Btuh Equiv. AVF (cfm) 193 103 Req. total capacity at 0.70 SHR 4.0 ton Heating Equipment Summary Cooling Equipment Summary Trade Trade TRANE Model Cond 4TTR704BAl AHRI ref Coil TEM6AOC48H41++TDR+DF AHRI ref 8875412 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 12.9 kW Sensible cooling 33600 Btuh Heating output 44013 Btuh Latent cooling 14400 Btuh Temperature rise 25 OF Total cooling 48000 Btuh Actual air flow 1600 cfm Actual air flow 1600 cfm Air flow factor 0.036 cfm/Btuh Air flow factor 0.045 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.80 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wri9tit�oft- 2018Oct-19 12:53:22 "Ift RightSufteM Universal 2018 18.0.31 FISUG8101 Page 1 ...ets%Wrightsoft HVAC\MARSHALL RES-NAVIONDR.rup Calc=MJB Front Doorfaces: S Project Summary Job: wrightsoft® y Date: Oct 19, 2018 AHU 2 By: QUICK CALCS, INC. 317STLLJCIE LANE, FORT PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Emat: QUICKCALCS®AOL.COM Project• • For: MARSHALL RESIDENCE PACE 2000, INC. NAVION DRIVE, PORTS" LUCIE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TO 15 OF Daily range Relative humidity M 50 % Moisture difference 61 gdib Heating Summary Sensible Cooling Equipment Load Sizing Structure 9001 Btuh Structure 11968 Btuh Ducts 2531 Btuh Ducts 1676 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh none (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 11531 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipmenf sensible load 12962 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2941 Btuh Ducts 1007 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) Area (ft2) 1172 1172 Equipment latent load 3948 Btuh Volume (ft� 10868 10868 Air changes/hour 0.36 0.19 Equipment Total Load (Sen+Lat) 16910 Btuh Equiv. AVF (cfm) 64 34 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR40181-1 AHRI ref Coil TEM6AOB24H21++TDR AHRI ref 7567539 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 11.3 kW Sensible cooling 13160 Btuh Heating output 38670 Btuh Latent cooling 5640 Btuh Temperature rise 56 OF Total cooling 18800 Btuh Actual air flow 627 cfm Actual air flow 627 cfm Air flow factor 0.054 cfm/Btuh Air flow factor 0.046 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.78 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wri9hts ft- 2018 OCt-191Z53:22 �. •""' —Z RghtSu@eO Unimsal 201818.0.31 RSU08101 Page ...etawrightsoft HVAMMARSHALL RES- NAVION DR.mp CA = MJ8 Front Door faces: S wrightsoft• Right-J® Worksheet AHU 1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL34946 Plane: 772-4666799 Fax 772-466-6796 EmaO: OUICKCALCS®AOL.COM Job: Date: Oct 19, 2018 By: 1 Room rlame AHU 1 BEDROOM 2 2 6gx/sed wall 200.3 it 31.0 1l 3 Room height 16.1 it 10.0 it beavcool 4 5 Room tlumemsiorls Room area 2754.0 IF 1.0 x 233.0 1t 233o fF Ty Construction llwlue Or IfFM Area QF) Load Area (1F) Load number (BtutNF-°F) (BIUMF) or perimeter (a) (Bluh) or perimeter (a) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 13A-0acs - �_-- 2glazing cir bW-e _p - 0.143 0.650 - V n. --- 4.00 18.20 2.19 14.99 '-1386 120 11098 0 4398 2184 -"- 2402 1799 180 24 156 0 - 825 437 - - 341 360 2 gladrg cir bw-e 0.660 n 18.20 14.99 120 0 2194 1799 0 0 0 0 2glazing cir low-e 2glazirg clr-low-a, 0.650 __.._0.650-n._ n 0.00 __18.20 0.00 _14.99 0 --48 0 .,--_0_ 0 _.. 874 0 _.._720 0 _-_0. 0 _ ___0 0 0 " 0 ... 0 b 1aA-4ocs 2 glazing dr mow-e 2 glazing cir now-e 0.143 0.650 0.650 a a a 4.00 19.20 1820 2.19 33.77 33.77 864 12 16 836 0 0 3347 218 291 1829 405 540 0 0 0 0 0 0 0 0 0 0 0 0 - 11D0___,.,�___ _,--_ _0.390__e_-0.00_..0.00 ___0_`0__.__o ..�__. 0.....____o 0 ..__..0 -0 __- 2giazing clrbw-e 2glazing,drlow-e.. _ 13A-4ocs 0.650 --.-_0.650 0.143 se _se_ s 11120 11120 4.00 17.79 .__23.96 2.19 6 _ 18 554 4 _-___- _4 411 106 -- 318 1646 104 .___-419 899 0 . ___ 0 0 0 _ _ -.-0 0 0 _ - . 0 0 0 . _ _ 0 0 2glmirg, clr IDw-e 0.650 s 18.20 14.99 6 6 109 90 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 16 16 291 240 0 0 0 0 2 giazirg cir low-e 2 glazing cir low-e 0.650 0.650 s s 18.20 18.20 14.99 14.99 6 8 6 8 109 146 90 120 0 0 0 0 0 0 0 0 2 glazing cir law-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing cir bw-e 2 glazirg dr low-e 2 glazlrg cir low-e 0.650 0.650 0.650 s s s 18.20 18.20 18.20 14.99 14.99 14.99 11 12 36 11 12 36 200 218 655 165 180 540 0 0 0 0 0 0 0 0 0 0 0 0 -L=G 2aiazin¢drlow-e -13A-4cas - 0.650 -0.143 a- -SSW 1120___14.99 _.. 4.00 ...2.19 48 _..__w 48 _T___4 874 _ --178 720 ._.- 97 0 _ __0 0 _ __-0. 0 _ ___0 0 -__ _ _0 2 glazing dr low-e 0.650 sw 18.20 17.79 6 4 106 104 0 0 0 0 .. 2glazing-drbw7e_ _. -__-._0.650 _w. _-_1&20 . __23.96 _v. __18 ___ 4 3111 __ _4111 .. -0 ._ _ -0- _ 0 _ 0 1p1�-C 13A-4s oo 0.143 w 4.00 2.19 317 __._ 309 1237 676 _ 130 _ 130 521 _ 284 2 glazing, cir IGw-e 0.660 w 0.00 0.00 0 0 0 0 0 0 0 0 G--G 2glazirg dr low-e 0.650 w 18.20 3377 8 0 146 270 0 0 0 0 L{ 2dazinaarbw-e--- , 1._- ° o --0.650 -w- . -0.00 _..._0.00 --_0 _ _____._° - -.---0 ------° _ - -- 923 _ _,__o .. 110 - _.... _276 F22A1ph 1.358 - 38.02 0.00 2754 200 7614 0 233 31 1179 0 6 c) AED excursion 0 -11 Emetope loss/gain 29582 18815 2871 1250 12 a) Willratlon 5927 1701 564 162 b) Roomlentllallon 0 0 0 0 13 Memal gains: Oocugarts (9 230 0 0 0 0 Appliaraes/other 6200 500 Subtotal trxs 6to 13) 35509 26716 3435 1912 Less exdemal load 0 0 0 0 Less immsfer 0 ° 0 0 Redistribution 0 ° 109 38 14 Subtotal 35509 26716 3544 1950 15 Duct loads 26% 32% 9127 8531 26% 49% 911 951 Total room Intl 44636 35248 4455 2901 Air required (of m) 1600 1600 160 132 Calculations awroved byACCA to meet all requirements of Manual J 8th Ed. -fia- wrl9ti�of'C- 2018-0ct-191Z53:22 A RightSuleM Universal 201818.0.31 RSU08101 Page 1 ...ets\Wr'ghtsoft HVAC\MARSHALL RES- NAVION DR.rup Cab = We Front Door feces: S wrightsoft° Right-JO Worksheet Jeb- AHU 7 Date: Oct 19, 2018 By - QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772A66-6796 Email: OUICKCALCS®AOL.COM 1 Room name CLST 2 BATH 2 2 Eked wall 20 it 10.0 it 3 Room height 10.0 1t hxol/cool 10.0 1t heat/cool 4 5 Room dimensions Room area 20 x 9.0 it 18.0 IF 7.0 x 10.0 it 70.0 112 Ty Construction U}%due Or HTM Area OF) Load Area QP) Load number (BiuhlfR°F) (BtuMP) or perimeter (it) (Bluh) or perimeter (it) (Btuh) Heat Cool Gross WP/S Heal Cml Gross N/PIS Heat C001 8 73A-9ocs 2 glazing cir low-e 0.143 0.650 -n n .4.00 18.20 ' 2.19 14.99 -`__p 0 ___20 0 _---- .80 0 __ 0 O.O 0 0 _ 0 0 --0 0 2 glazing dr low-e 0.650 n 1112D 14.99 0 0 0 0 0 0 0 0 11 ..Z 2 glazing cir bw-e 2glazing drbw-e. 0.650 0.650 n __n_ 0.00 18.2D O.00 ___14.99 0 0 0 _.__. _. 0 0 _. _-__-0 0 --- __0 0 ___..__._0 0 _ .. _ _._0 0 _. _..._ 0 0 ... _ _0 13A-0acs 2 glazing cir low-e 2 glazing, dr bw-e 0. 0.650650 0.850 a a a 1882D 20 18.,20 279 33.77 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _. .11 D0.__. .__._ 13A-0Ocs -_0.390 0.143 _e_ se __.. 0.00 4.00 -0.00 2-19 ----0 0 ._ 0 0 ------- 0 0 _. 0 0 -"-O- 0 -'__0' 0 -0 0 - 0 0 2 glazing cir bw-e 2 glazing dr:IoWne _ - 13A-0acs 0.650 _ . 0.650 0.143 se se. s 18.20 _ ._.18.20 4.00 17.79 23.96 218 0 ._ _ _0.. 0 0 _ _. _0 0 0 _ 0 0 0 ____0 0 0 __ _ --o 0 0 _ _ ..0 0 0 - 0 0 0 _ _ _ _ 0 0 2 glazing dr low-e 0.650 s 18.2D 14.99 0 0 0 0 0 0 0 0 2glwing cir bw-e 0.650 s 182D 14.99 0 0 0 0 0 0 0 0 2glazing cir bw-e 2glazirlg dr bw-e 0.650 0.650 S s 18.2D 11120 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing cir bw-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing dr IOW-e 2 glazing dr bw-e 2 glazing cir low-e 0.650 0.650 0.650 s s s 18.20 18.2D 18,20 14.99 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -_ 2dlazind dr low_e -13A-400S 0.650 0.143 .-S- sw 18.20 .. 4.00 14.99 _ __ 218 0 _.e.._ -0 0 _�.0 _-_ 0 0 ---0-- 0 0 . __0 0 _. __.0 0 _ . _ _0 0 _ . _0 . 2 glazing cir bw-e 2g1azing drlow-e__._ 0.650 __-- 0.650 sw sw_ 18.20 11120 17.79 ---23.96 0 ._ .. 0 0 __ _ _. 0--._ 0 0 0 __ --0 0 _._._0 0 . ._ _ 0 0 _ _ 0 0 _ _ __ 0 laklocs 0.143 w 4-OD 2.19 0 0 0 0 100 92 368 201 2 glazing dr low-e 2 glazing cir IOw-e 0.650 0.650 w w 0.00 18.20 0.00 33.77 0 0 0 0 0 0 0 0 0 8 0 0 0 146 0 270 -- 0. F F- 201azIr(1 dr low-0.__ 16A30ad____ _ . 22A-tph 0.650_w_-- _1.358 1.358 ._ _ 0.00 ._.__ 8,02 3302 ^0.00 ._ _2.00 0.00 _0 __..__8 18 ---_0 .._ _ 7 2 _0_ 6.._ 76 ___-._._0 18 0 .__..__.0 _. _70 70 - _.. _ 10 __ __ 10 10 __.. -0 _._ __ 9 360 .. _... _._._0 0 6 c) AE1 a ursion 0 113 Enwiope loss/gain 162 59 903 607 12 a) hAi9ration 36 10 182 52 b) Roomwmilation 0 0 0 0 13 Internal gains; Occupants ® 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6to 13) 199 69 1085 659 Less eldemel load 0 0 0 0 ess Ltransfer D 0 0 0 Redistribution -199 -69 0 0 14 Subtotal 0 0 1085 669 15 Duct loads 26% 41. 0 0 26% 49 2791 321 Total room Ioad 0 0 1364 980 Air negimed (cfm) 0 0 49 44 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. 2016Oct-191253:22 ' ALL RES- N Universal rup Cole = RSU08101 Page 2 ...ets\WrigMsoft HVAC\MARSHALL RES- NAVION DR.mp Cab = MJB Front Door faces: S wrightsof * Right-J@ Worksheet Job: aHu i Date: Oct 19, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LAKE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS®AOL.COM 1 Room name LAUNDRY HALL 2 Eposed wall O It 0 it 3 Room heghl 10.0 ft beal/000l 10.0 It heat/cool 4 Room dunensions 9.0 x 10.0 It 4.0 x 10.0 It 5 Room area 90.0 IF 40.0 IF Ty Construction LL\tue Or HTM Area Load AM ' number (BluMR°F) (BtuMF) or perks ter (0) (Bluh) or perimeter (0) (Bluh) Heal Oool Gross NIBS Heat Cool Gross WP/S Heat Cool 6 13A-4bcs.�-____ 0.143 n 4.00 219 __-_ _0 _,O_ __-O 0 _ _ _O______.0 ____0 .____ a 2 glazing, cir low-e- 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing dr bw-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 -2 glazing cir law-e 2glazing drlow,e. 0.650 ---0.650 n _.n. 0.00 _ _ 18.20 0.00 --14.99--- 0 _0 0 0 _ __ . .0 0 - 0 0 _ _-_0 0 ____- 0 0 _ _ ---0 0 _ _ __. 0 13A-4acs 0.143 a 4.OD 2.19 0 0 0 0 0 0 0 0 2 glazing cir low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing cir low-e 0.650 a 11120 33.77 0 0 0 0 0 0 0 0 11D0__-..�_ _ e_ 0.00 0.00 0 6 0 0 13A-0ocs .___0.390 0.143 Se __ 4.00 219 0 0 0 _ __0 0 _____6 0 _ __. __0. 0 _ __ _.0 0 __.__._ 0 2 glazing, cir low-e 0.650 se 18,20 17.79 0 0 0 0 0 0 0 0 _. . 2glazing cir bw,e-_ - 0.650 _se- _ _ 18.20 -_. 23.96 _ - .0 .0 . _. _._ 0 _ _s. 0 _-_0 _ __ _.0 .. _0 _0 13AAWS 0.143 s 4.00 219 0 0 0 0 0 0 0 0 291MIn,}cir low-e 2 glazing clr low-e 0.650 0.650 s s 18.2.0 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2glazln_m cir Tow-e 2 glazing, cir low-e 0.650 0.650 s s 18.2.0 18.20 14.99 14,99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 gtazlrxy dr low-e 2glazirx1 cir bw-e 2glazirxy cir low-e 0.650 0.650 0.650 s s s 18.20 18.20 1820 14.99 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2o0azirq.-driow-e___. ___-0.650 _ 18.20 14.99 0 0 0 0 _. 0 0 0 y/ 13A-400s 0.143 _s_ sw 4.00 _ 2.19 ___ 0 _. 0 0 0 0 _ 0 ._. .0 .. ___0 0 2glazing cir low-e 0.650 sw 18.20 17.79 0 0 0 0 0 0 0 0 t�-GG 29lazing clr.low-e_- __..__0.650 -sw_ --1&20 _ _ 23.96 _ -0- __- 0- 0 _ _0 --,-0--- __0. _ 0 _ - _ 0 -0.143 w 4.00 2.19 0 0 0 0 0 0 0 0 2 glazing clr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 N13A-400S 2 glazing cir tow-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2dwIrKL cir low-e 0.650 0.00 0 0 C.__._ -16A.30ad._-_....- . ._._ - 0.032 _w_-0.00 __ .. _ 0.90 ..._.2.24 __0 _-_--0 _ -------0 -_0 _ _ -0 .._ __.0 .-----0 __-_._0 _ .__._0 ._,0 ._ 0 .__0 ..___ --0 F 22A-tph 1.358 - 38.02 0.00 90 _ _ 0 0 0 40 _ 0 0 0 6 c)AED excursion -6 0 Emelope loss/gain 0 -6 0 0 12 a) Wmratlon 0 0 0 0 b) RoomwmtIWlon 0 0 0 0 13 Internal gairGs: Occupants (9 230 0 0 0 0 App[ianoes/other 10DO 0 Sudtal (lines 6 to 13) 0 994 0 0 Less e)lerrel load 0 0 0 0 Less itarsfer 0 0 0 0 RedistdbLLion 0 0 0 0 14 Subtotal 0 994 0 0 15 Duct loads 26% 499b 1 0 485 26°h 49% 0 0 Total room load 0 1479 0 0 Air req-ed(of m) 0 67 0 0 ., Calculations aWroved bVACCA to meet all requirements of Manual J 8th Ed. c "rw wrlgtitsof[- 20180ct-191253:22 A RightSufte® Universal 2018 18.0.31 RSUD8101 Page 3 ...ets\Wrightsod HVAC\MARSHALL RES- NAVION DR.mp Calc = MJB Front Door Faces: S wrightsofr Right-J@ Worksheet Job- AHU 1 Date: Oct 19, 2018 QUICK CALCS, INC. By. 317 ST LLICIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-9796 Ema1: OUICKCALCSOAOL.COM 1 Room mans GREAT ROOM WCHEN 2 Exposed wall 31.0 It 0 It 3 Room height 30.0 it beat/cool 10.0 It head/cool 4 5 Room dimemlors Room arm 1.0 x 628.0 it 628.0 IS 1.0 x 230.0 It 230.0 fP Ty Construction LLXWW Or I-f!M Area OP) Load Arai PP) Load number (BtulNti F) (BfuINP) or perimeter (11) (Btuh) or perimeter (0) (Btuh) Heat Cool Gross WP/S Heat CWl Gross N/P/S Heal Cool 6 2 glazing, cir low-e 2 glazing cir low-e 0.143 0.650 0.650 n n n 4.00 1&20 18.20 � --2.19 14.99 14.99 - 988 48 120 772 0 0 _ '3091 874 2184 _ _-955 720 1799 _ o 0 0 o 0 0 o 0 0 _-__Q 0 0 11 2glazing cir low-e 2glazirg, cir low-e. 0.650 .__ _ 0.650 n --n 0.00 ---18.20 0.00 -_14.99 0 _____-48 0 ___ _.. 0._. 0 --- 874 0 _ _--720 0 _ _ _ _ --0 0 _..__ __0.. 0 ._., _ 0 0 ._.__. 0 13A-90cs 2 glazing cir low-e 0.143 0.650 a a 4.00 18.20 2.19 33.77 171 0 171 0 6a5 0 374 0 0 0 0 0 0 0 0 0 2 glazing cir low-e 0.650 a 11120 33.77 0 0 0 0 0 0 0 0 11 D0 _ _ _ 13A-0acs 0.390 0.143 _e . se _ _ 0.00 4.00 ___0.00 2.19 __ _ _0 0 ___0 0 -,---0 0 . 0 0 ..._ 0 0 ._ _ _ _._0 0 -0 0 _ _ _ ._ 0 0 _ 2 glazing cir low-e 2glazlrx-1 clr,bw-e. __. 0.650 _0.650 se se. 18.20 _ 18.20 17.79 _..23.96 0 _.� - 0 0 _-- -..0 0 _ 0 0 -_ _o 0 _ --_0 0 _ _ __ 0 d _ .._.0 0 _ _0 13A-40os 0.143 s 4.00 219 0 0 0 0 0 0 0 0 2 glazing cir low-e 2 glazing cir low-e 0.650 0.650 s s 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing cir low-e 2glazing, cir low-e 0.650 0.650 s s 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2glazing cirbw-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing cir low-e 2 glazing, cir low-e 2 glazing dr low-e 0.650 0.650 0.650 s s s 18.20 18.20 18.20 14.99 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W 2dazinci drbw-e __-- 13A-flocs ___0.650 0.143 _s.- sw la20 4.00 _ 14.99 ^ 2.19 0 _.0 _ 0 _-_-.._..0 0 0 0 ._ _-_0 0 _ 0 0 .. __,_0 0 . _ _0 0 _ .._ ._ 0 2glad g, drbw-e . 0.650 sw 18.20 17.79 0 0 0 0 0 0 0 0 - 2gIazIMg clrbwre- _ 0.650 0.143 sw_ w 18.20 4.00 .23,96 2.19 -----0 27 ____..0 27 _ _-__._.-o 108 .____.0 59 .__ _. _ 0 0 __0 0 ,.._ _ _0 0 _0 0 2 glazirg, cir low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 b13A-4ocs 2 glazing dr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2o0azlrladr.bw:e_ _.__0.650 w_0.00--__-0.00 _0 0 0 0 _._.. 16A-Iph _ ._- __8.90___2.00 __0 658?58__._.�5001250 _.__0.____ _0 _ __ . _ _. _0 ---0 __.._..- F F 22A-0ph _- _- _ _ y 1.358 1.358 ._� _ _ - 38.02 0.00 �-- 628 31 1179 0 _._. __..0 230 -0-.- 0 0 __..___0 0 6 c)A®excursion -42 -17 En elope loss/gain 0494 6568 0 -17 12 a) Wiftration 2168 619 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Oocuparts 0 230 0 0 0 0 Appliances/other 0 3000 Sublotal (linxs 6 to 13) 11652 7188 0 2983 Less e#errel load o 0 0 0 Less tmrsfer o 0 0 0 Reclistribrlbn 89 31 0 0 14 Subtotal 11741 7219 0 2983 15 Duct loads 26°e 075 3018 0 26% 49% 0 1454 Total room Intl I 1 14759 1 7219 0 4437 Air required (of m) 529 328 0 201 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -rk- wr19F� oR- 2018-0ct-1912:53:22 A Right-SufteO Universal 201818.0.31 RSUD8101 Page 4 ...ets\Wrghtsoft HVAC\MARSHALL RES- NAVION DR.mp Cab = WS Front Dcor faces: S wrightsoft- Right-J@ Worksheet Job: AHU 1 Date: Oct 19, 2018 QUICK CALCS, INC. By. 317STLLICIE LANE, FORT PIERCE, FL34946Phone:772-466-6799 Fax 772-466-6796 Email OUICKCALCS(DAOL.COM 1 Room name PANTRY DINING ROOM 2 Exposed wag 0 a 18.0 It 3 Room height 10.0 It heaVccol 10.0 ft tleaVocol 4 Room dunenslons 5.0 x ao It 14.0 x 16.0 It 5 Room area 25.0 fP 224.0 1P Ty Constnxtlon LYlelue Or FlTM Area gP) Load Aran OP) Load number (BluhrtP-°F) (&uMI2) or perimeter (a) (Rtuh) or perimeter (it) (Rtuh) Heat TCool Gross N/P/S Heat Cool Gross N/PIS Heat Cool 6 . _ - -,. . n - n 4.00 18.20 - 2.10 14.99 .� -0-0 0 0 U 0 a 0 _ .. _ U 0 -.._ U 0 0 0 _ 0 0 13A-0ocs ____-_- . 2 glazlog cir low-e __._-0.143 0.650 2 glazlrq drbw-e 0.650 n 1&20 14.99 0 0 0 0 0 0 0 0 11 2 glazinKj cir bw-e 2glazirlg,clrlow-e 0.650 .0.650 n -_n--.. 0.00 1&20 0.00 v.,_14.99 0 _._. �._. 0 0 _. ._ 0..__...__0- 0 0 _ __0.`__._.0._ 0 0 ._._..0 0 ____0 0 ,.,__...0 __. 2 glazlcs 2 glazing, dr low-e 2 glazing, dr low-e 0.650 0.650 0.650 a a a 18.20 &20 18.20 2.77 33.77 33.77 0 0 0 0 0 0 0 0 0 0 0 0 40 0 0 40 0 0 160 0 0 88 0 0 11D0e __._-. a_ 0.00 0.00-- 0 0._ 0 0 0 0 _ 13A4ocs _0.390 0.143 . _ - 5e _ __ 4.00 2.19 „0 0 0 0 _ 0 _0 -� -0 _ _ _ �0 0 _-_ 0 2 glazing, dr low-e 0.650 se 18.20 17.79 0 0 0 0 0 0 0 0 . 2glazlrg,-drbw-e �.0.650 _se- .. 1&20 ___23.96 _�__,0 __. 0 .__..__ A _ 0. - - _--0 _. __0 _ ____.p _- __.0 13AA00S 0.143 s 4.00 2.19 0 0 0 140 83 332 182 2 glazlrg, cir low-e 2gIaZIfxjdrbw-e Q650 0.650 s s 18.2D 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 16 0 16 0 291 0 240 2 glazIrxj dr low-e 2 glazing, cir low-e 0.650 0.650 s s 14120 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, dr bw-e 2 glazlrxy dr low-e 2 glazing, cir low-e 0.650 0.650 0.650 s s s 18.20 ia20 1820 14.99 14,99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 11 12 18 11 12 18 200 218 328 165 180 270 l¢r 2 dazirq, dr low,-e _. 13A-0ocs ___0.650 0.143 -5 Sw ..-_18.2D 4.00 -, _14.99 2.19 0 0 0.__. 0 _0 0 _ _._.0 0 _._.-_. 0. 0 _._ 0 0 ... _ _0 0 _ 0 0 2glazirg, clr low-e 0.650 sw 18.20 17.79 0 0 0 0 0 0 0 0 2 glazing, drbw-e___ -_.__0.650 sw.. .-._1&20 23,911 -_ _. _ 0 _ ---_0 __0 ._ _-0 . _ 0. _. -._0 _ 0 ,h __--.0 0 13A-4oes 0.143 w Ass 2.19 0 0 0 0 0 0 0 2 glazing cir low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazlrg, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 dazirin cir low-e - 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 C_.._16A3oad___.__._ - --- _.r_0.032.-___0.90__.2.24__.._._0-__0__0___. - - - - -- _- --- _050_..._60 - - - --- --- ._-..._45 _ ._. 112 F 22A-I 1.358 - 38.02 0.00 --_ --- 25 0 0 0 - ! 224 18 684 0 6 c)AED mursion -1 -11 E a Lope loss/gain 0 -1 2259 1225 12 a) hdillraiion 0 0 328 94 b) Roorn lemilalion 0 0 0 0 13 Memal gains: Occupants (9 230 0 0 0 0 Appliances/other 100 500 Subtotal gross 6 to 13) 0 99 2587 1819 Less exterral load 0 0 0 0 Less trartster 0 0 0 0 Redistribtleon 0 0 0 0 14 Subtotal 0 99 2587 1819 15 Duct loads 26% 49% 0 48 26% 49% 665 897 Total room load 0 148 3252 2706 Air regbtred (of m) 0 7 117 123 Calculations awroved WACCA to meet all requirements of Manual J 8th Ed. -rld- w�tghfsoft- 2018.Oct-1912:53:22 rA Right-Sute® Universal 2018 18.0.31 RSU08101 Page 5 SH ...etsmIghtsoft HVAC%MARALL RES- NAVION DR.mp Calc= MJ8 Front Door faces: S ++ wrightsoft Right-J® WOrksheet Job: AHU 1 Date: Oct 1g, 2018 QUICK CALCS, INC. By: 317 ST LUCIE LADE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name FOYER POWDER 2 Exposed well 8.0 1t 0 it 3 Room helgM 27.5 It heat/cool 10.0 it heat/cool 4 5 Room dimensions Room area 8.0 x 220 it 176.0 JP 1.0 x 36.0 it 36.0 tP Ty Construction lllelue Or HTM Area Area number (BtutNti°F) (Numv) or perimeter (ft) (BlW) or perimeter (a) (Rtuh) Heat Cool Gross WP/S Heat Cool Gross WPM Heat Cool 8 _. _._-__ 13A-4acs 2 glazing cir low-e ___-._ 0.143 0.650 __ n n _.._ 400 1a20 , n 2.19 14.99 0 0 " .O 0 _ ____0___ 0 ..O 0 .___._- d 0 _ _0 0 ___-r.0 0 O 0 2 glazing cir low-e 0.650 n 1&20 14.99 0 0 �O 0 0 0 0 0 11 2 glazlnlg, ciLIDw-e 2glazing drlow,e 0.650 -__0.650 n _n_ 0.00 _law 0.00 __14.99 0 . _. . 0 0 _._ __-0 - 0 0.. 0 _ _ __0 0 _ _ . _ 0- 0 __ 0 0 _ .. _. __0__ 0 0 2 glazing 2 glazing cir low-e 2 glazing cir low-e 0.650 0.650 0.850 a a a 400 18.20 18.20 33.77 3.77 33.77 170 0 0 110 0 0 460 0 0 250 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11D0_____ 13A-4ocs _ 0.390 0.143 _e- se _ „-0.00 4.06 __ 0.00 2-19 0___ _ _ -_0 0 __0 _�. 0 _.0 _ _ 0 0. 0 ..___.__0 0 _0 0 __.._ -O 0 .__--0 __. 2glazirg, clr bw-e 2glazing clr.low-e_..... 0.650 _ _ -.. 0.650 as _se.. 18.20 - __18.20 17.79 __2a96 0 0 0 __.. o 0 _ _0 0 __- 0 0 . 0 0 0 0 �--. 0 13A-4OOs 0.143 s 4.00 2.19 240 .. 184 737 403 ----_o 0 ..�.-_ _ 0 ._. -0 0 ._ 0 2 glazing dr low-e 2 glazing Gr bw-e 0.650 0.650 s s 78.2D 18.2D 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing elr bw-e 2 glazing cir bw-e 0.650 0.650 s s 18.20 18.20 14.99 14.99 0 8 0 8 0 146 0 120 0 0 0 0 0 0 0 0 2 glazing cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing cir low-e 2 glazing dr bw-e 2 glazing cir low-e 0.650 0.650 0.650 s s s 1a20 M20 18.20 14.99 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 w1r'---� 2o0azlrxL-clrbw-e__ _ 13A-40cs .._�0.650 0.143 _s_ sw _18.20 4.00 ___14.99 2.19 .__ _ 48 0 _____48 0 __874 '0 _720 0 __-..0 0 _______0 0 -0 ' 0 0 --- 0 2glazlrg, cir low-e 0.650 sw 1a20 17.79 0 0 0 0 0 0 0 0 �--G 20azI g-clCbw-e _ _ 13A-4ocs . _ 0.650 0.143 sw. w _ 111,20 4.00 -. _23.98 219 _ ._. _.0 0 _ _ _ __.0 0 __-.. _0 0 _ ------ 0 0 _ ___ 0 0 _____0 0 _... _ -0 0 -----_0 0 2 glazing cir bw-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing cir bw-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 p__.. 2 olazln¢ clr low-e_ 18A30ad ..__ _ .__ .. _0.650 _ 0.032 . w_ ._: - 0.00 - 0.80. _-0.00 __ 2.24 . --. _..0 ..._ _ 736 __._0 .. 136 __._ _ 0 _____772 -0-- �. __305 o _ . 86 _ __ 0 . _ _- 38 _ 0 _._-_-32 0 �..__ __81 F 22Aa 1.3% - 38.02 0.00 176 8 304 0 36 0 0 0 6 c)AED excursion 5 0 Emelope loss/gain 2650 1808 32 80 12 a) Wiltratlon 650 186 0 0 b) Room ventilation 0 0 0 0 13 "emal gains: Occupants (§ 230 0 0 0 0 Appilances/other 0 0 Subtotal 01nes 6 to 13) 3300 1994 32 80 Less wdemal load 0 0 0 0 Lesstransfer 0 0 0 0 Recstdblbn 3 8 5 13 14 Subtotal 3303 2002 38 94 15 Duot leads 261/6 0% 849 0 26% 49% 10 46 Total mom load 4152 2002 47 139 Air requ'ned (o1m) 149 81 2 6 Calculations awroved bvACCA to meet all requirements of Manual J 8th Ed. -Fi} wrighisoPC- 2018-0ct-191253:22 C� RightSufteO Universal 2118 18.0.31 RSU08101 Page 6 ...ets\Wrghtsoft HVACIMARSHALL RES- NAVION DR.nup Cab = MJS Front Door (aces: S wrightsoft Right-J® Worksheet Job: AHU 1 Date: Oct 19, 2018 QUICK CALCS, INC. By: 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 EMU: OUICKCALCS(PAOL.COM 1 2 3 4 5 Room name Brposed wag Room heght Room dmersio s Room area HALLWAY 0 It 10.0 1t heat/cool 3.0 x 4.0 it 12-0 1F OFFICE 25.3 1t 12-0 it Cleat/cool 1.0 x 2220 It 222.0 IF TY Construclfon number ll\alue (RtuMt--F) Or HTM (Rtuh4F) Area 0F) or perimeter (it) Load (8tuh) Arm OF) or perimeter (0) Load (eluh) Heat Cool Gross NIP/3 Heat Cool Gross N/P/S Heat Cool 6 11 .0.143 0.650 0.650 0.650 --__,0.650 0.143 0.650 0.650 0.390 �0.143 0.650 __0.650 0.143 Q650 Q650 0.650 0.650 0.650 0.650 0.650 0.650 0.650 0.143 0.650 .w.-0.110_sw: 0.143 0.650 0.650 _0.650 _ _0.032-� 1.358 . n_ n n n -_n_ a a a e_ se,_ as se_.._. s a s s s s s s s s_--1&20 SW 819 w w w _w_ - .400 1829 1820 0.00 18.20 4.00 18.20 18.20 _0.00 4.00 1820 18.20 4.00 18.20 18.20 18.20 18.20 0.00 18.20 18.20 18.20 4.06 18.20 _78.20 4o) 0.00 18.20 -,_10.00, _._ 0.90 38.02 _; . ..___6 0 0 0 _. 0 79 0 0 _ ___0 97 104 .._... __119 105 90 0 0 0 0 0 0 270 97 104 ___419 131 0 0 ----.0 .,. _ .497 0 13A-4acs 2 glazing clr,low-e 2 glazing cir bw-e 2 glazing cir bw-e 2glazing-cir IDw.;e _ MA-4ccs 2 glazirx3 cir low-e 2 glazing cir low-e 13A-flocs 2 glazing cir low-e 2glazmg, drlow;e_ 13A-4ocs 2 glazUg cir low-e 2 glazing cir [ow-e 2 glazing cir low-e 2 glazirg cir ow-e 2glazing cir low-e 2glazirxJ, dr low-e 2 glazing, dr low-e 2 glazing cir low-e 2glazlnadr low--e. -13A-0oCs - 2 glazing dr law-e 2glazmg-dflow�e_._ 13A-00DS 2 glazing cir lDw-e 2 glazing cir bw-e 2glazin4 drbw.e _ _16A-30ad _ 22,A-tph - -2./9 14.99 14.99 0.00 -14.99 219 33.77 33.77 _ 0.00 �219 17.79 _ _23.98 2-19 14.99 14.99 14.99 14.99 0.00 14.99 14.99 14.99 14.99 � 2.18 17.79 _ 23.96-.___..._0 219 0.00 33.77 i0.00 --.2.24_.-_ 0.00 --0 0 0. 0 _,__0 0 0 0 0 ^0 0 .. ,0 0 0 0 0 0 0 0 0 0 0 -� �0 0 0 0 0 _____.0 12_-� 12 0 0 0 0 _- __ 0 0 0 0 0 '0 0- _0 0 0 0 0 0 0 0 0 0 0 -� 0 0 ., _ _ 0 0 0 0 0 .._12_ 0 O 0 0 0 _w .__0 0 0 0 0 - a 0 0 0 .__ _ __0 0 0 0 0 ._ a 0 0 0 __._.0 36 0 0 ___ 0 68 6 .. 18 72 6 0 0 0 0 0 0 18 0 ___-0 ------0 0 0 0 _.. __.._ 0 36 0 0 0 Y-.�6 0 0 0 ..__0 144 0 0 0 .._. 178 106 _. a - 318 192 109 0 0 0 0 0 0 328 0 - _ 178 106 -,,---318 240 0 0 -_0 ___.-199 960 kb . __ 0 0 _ _ 0 0 0 0 0 0 0 0 0 0 0 - ~-_ 0 0 _ ._0 0 0 0 __ _ ___0 _ 11 0 0 0 _._ _ _ ._0 0 0 0 0 0 0 0 0 0 0 -0 0 _ .___.0 0 0 0 ___,__0 ----,..27 0 -45 4 , _ ._....4 48 6 0 0 0 0 0 0 18 0 45 4 _:_.._.__4 60 0 0 __0 v__ .222 25 =mG �---G --86 6 _._ 18 60 0 0 __-0 __ _222 222 .0 F 6 c)AED excursion 0 -18 Envelope loss/gam 11 27 3378 2396 12 a) Wigr4tion b) Roomeentilation 0 0 0 0 553 0 159 0 13 htemal gairs: Occuparts a 230 Appgarxces/other 0 0 0 0 0 500 Sublotal Qines 6 to 13) 11 27 3931 3054 14 15 Less eldernlal load Less transfer Redstdbfiion Subtotal Duot loads 28% 49% 0 0 -11 0 0 0 0 -27 0 0 26% 495/6 0 0 2 3934 1011 0 0 6 3060 1492 Total room load Air required (ofm) 0 0 0 0 4945 177 4552 207 Calculations awroved byACCA to meet all requirements of Manual J 8th Ed. -fjd- +tsoH- 2018-Oct-1912:53:22 ' RghtSuge® Universal 2018 18.0.31 r1SU08101 Page 7 ...e[s\Wrightsod HVAC\MARSHALL RES-NAVION DR.mp CaIc=MJ8 Front Doorfaces: S fl wrightsofC Right-J® Worksheet Job: AHU 1 Date: Oct 19, 2018 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS(9?AOL.COM 1 Room name M WIC_ M BATH 2 Exposed wail 18.0 It 11.0 It 3 Room height 10.0 It heat/0001 11.0 it heat/cool 4 Room dunersions 8.0 x 10.0 It 1.0 x 170.0 it 5 Room area 80.0 IP 170.0 IP Ty Construction U-%slue Or HTM Area OF) Load Area Oil) Load number (Bluhdr�°h) (BtuMP) or perimeter (11) (Bluh) or perimeter (it) (Btuh) Heat I Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 8 73A-flocs � 2 glazing Or low-e 2glazing clr low-e 0.143 0.650 0.650 n n, n 4.00 18.20 18.20 01 -219 14.99 14.99 --�� 0 0 0 - �-�� - 0 0 0 ��-0 0 0 ----- - 0'-- 0 0 -�-�0 0 0 _ __ _ m0 0 0 0 0 0 0 - 2 glazing, dr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 11 2 glazingdr.bw_e__ - 0.650 --n -_18.2014.99.___-.-. _0 _______.0 ---- ._..0- _-__-0 0 ___._0 _._ - 0_0 __- 13A-4ocs 2 glazing, clr low-e 0.143 0.650 a a 4.00 18.20 2.19 33,77 100 0 100 0 400 0 219 0 99 0 83 0 332 0 162 0 2glazing dr bw-e 0.650 a 18.20 33,77 0 0 0 0 16 0 291 540 11130--__, 13A-4ocs ._-._0.390 0.143 e- se 0.00 4.00 0.00 - -219 0- . _ v0 0 ___._0 0 .-__.0 0 __0 0 _-.. ___0 _ 0 _0 0 _ . 0 0 _. _ .-_0 2glazing clr bw-e 2 glazing cir bw,e-.--0.650_se18.20--_23.96 0.650 se 18.20 17.79 0 ------ .-o 0 __,_._ 0__-_--0__--___0_- 0 0 0 _0__ 0 _.0 0 ____0 0 __0 13A-41ocs 0.143 s 4.00 2.19 80 74 296 162 22 22 88 48 2 glazing dr bw-e 2 glazing dr low-e 0.650 0.650 s s 18.20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing, dr bw-e 2 glazing dr low-e 0.650 0.650 s s 18.20 18.20 14.99 14.99 6 0 6 0 109 0 90 0 0 0 0 0 0 0 0 0 2glazlrxj dr law-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2glazing dr bw-e 0.650 s 18.21 14,99 0 0 0 0 0 0 0 0 2 glazing dr bw-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazlrg dr bw-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 _-=_G 20azimdr bw_e- _ 13A40cs _,,___0.650 0.143 s sw 18.20 4.00 _ _14.99 219 0 _. __-0 -o 0 ___a 0 _ _ 0 __.__-_0 0 �.___0 ,.. 0 0 0 .-0 0 0 2 glazing, dr bw-e 2glazirg dr.bwce_ _ 134-4ocs 0.650 0.650 0.143 sw sw_ w 18.20 __18.20 4.00 17.79 ___23.96 2.19 0 _. _. _._ _0 0 0 _ _ _-_0 0 0 -_-_ 0 0 0 ___._-o 0 0 _ __..-.. 0 0 0 _-. -0 0 0 ___ _.0 0 0 -.0 0 �G 2 glazing cir bw-e 2 glazing, dr bw-e 0.650 0.650 w w 0.00 18.20 0.00 33.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 L�GG C__ F 2olazirxl, dr.bw-e 10A-tph. _-` -- 22A-t 0.850 _ _0.032 1.358 w_ _:. - _. 0.00 --- 8.02 36.02 _0.00 _ 2.00 0.00 _0 _._-- _80 80 _ _ 0 _ -___18 18 0 -'-- 72 684 0 -_-170 0 0 --- 170 170 0 - _..-,111 _-- 11 0 _ 418 418 0 _�- 380 0 6 c)AED elxumlon -4 16 Emelope loss/gain 1562 646 1282 1165 12 a) WlBration 328 94 220 63 b) Roomlentilatlon o 0 0 0 13 Internal gains: Occupants ® 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6to 13) 1890 740 1502 1230 Less wdernal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution o 0 0 "0 14 subtotal 1890 740 1602 1230 15 Duct loads 26% 4M 486 361 26% 49% 386 600 Total room Intl 2375 1100 1889 1829 Air required(cfm) 85 50 88 83 Calculations awroved bvACCA to meet all requirements of Manual J 8th Ed. Rigt wrrghlsoHt- Universal 1 2018-Oct-191253:22 ...ets\WrigMsoR HVAC\MARSHALL RES- NAVON OR.rup Calc = MJB Front Door faces: S Page 8 wrightsott, Right-J® Worksheet Job: • AHu' Date: Oct 19, 2018 By: QUICK CALCS, INC. 317 ST LLICIE LAIC, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-M6 Email: OUICKCALCS@AOL.COM 1FR� M TOILET HISWIC20 It 7.0 ft 3 10.0 tt heat/cool 10.0 (t hea /cool 4slars 5 6.0 x 4.0 ft 24.0 fP 6.0 x 7.0 ft 42-0 fP Ty Construction Ll-%d a Or HTM Area QI-) Load Area QP) Load number (Bluh4P--F) (Bluh/fP) or perimeter (0) (Btuh) or perimeter (0) (Bluh) Heat Cool Gross N/P/S Heat Cool Gross WP5 Heal Ccol 6 ���(111� I---G 13A-flocs ��-_ 2glazing cir low-e _,___-0.143 0.650 __n n .-4A0 18.20 219 14.99 __ _-_,O 0 _-_._.0 0 _ -__a 0 ------ a 0 O._.__0 0 0 ___0 0 i 0 0 2glazing cir low-e 0.650 n 18.20 14.99 0 0 0 0 0 0 0 0 11 1(t-�;--GG 2 glazing cir low-e 2glazing, d(low:e_ _ 0.650 ____0-650 n -n 0.00 .__1820 0.00 ___14.99 0 0 0 --_ -_-.0 0 -----a 0 _'. _0 0 _ _ _-o 0 _.._ _._ 0 0 _ _ -- 0 0 . _. 0 1)/ 0.650 a 8..20 0 0 0 0 70 70 280 150 2gluins 2gluing or low-e 0.650 a 18.20 3.77 33.77 0 0 0' 0 0 0 0 0 2 glazing or low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 11D0__- 13A-0ocs _ -0.390 0.143 _e_ se -___0.00 4.00 0.00 2-19_ _-0 0._____0 0 __.�_ 0 0 0 .__ _.._ 0 0 __ 0 0 _ .. _ 0 _ _0 . . - 0 _ __0 � - 0 2glazirg. clr low-e 2glazirg Gr.bw-e. 13A-0ocs 0.65o _..._0.650 0.143 se _se s 18.20 - J8.20 4.00 17.79 23,96 2-19 0 ._ _- __0 0 0 _ _ . _ 0 0 0 .._.._--. 0 0 0 ._ _. -0 0 0 __-0 0 0 ._ 0__ 0 0 . ..0 0 0 _ __0 0 2 glazing clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing dr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing cir IDw-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing. cir bw-e 0.650 s 1820 14.99 0 0 0 0 0 0 0 0 2 glazing clr bw-e 2 gluing cir bw-e 0.650 0.650 s s 18.2o 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _.^ 201azin¢drbw=0 13A-4ocs __0.650 0.143 _ s sw ____18.20 4.00 14.99 .�. 2.19 ___0 0 0 0 0_ 0 _ 0____ 0 __0 0 __0- 0 _ ---0 0 __-_0 0 2 glazing dr low-e 0.650 sw 18.20 17.79 0 0 0 0 0 0 0 0 2 glazing.clr.bw-8___ 13A-0acs _ __. 0.650 0.143 _sw w - __18.20 4.00 _ _ 23.96 219 ._ - . ___0 0 _ _ 0 0 _.__0 0 _0_ _ 0 _ _ - - 0 0 _ .._ __ 0 0 . -- 0 0 _ _._ 0 0 )--G 2 glazing, dr bw-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2glazing, clr low-9 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2dazIrxL clr.bw-e_ _ __0.650 0.00 0 0 C.__. 16A30ad___ -.__ . ___ _0.032- _w •_ _ _ _ 0.9D ____.0.00 _2.24 .._ _._0 .._ _.24 .0. ,.--... 24 _ .22 _ . _0 _-54 -'.0 _.-_�42 _ - -0 __-o _ _. --38 . _.__. - 94 F 22A-tph 1.358 - 3&02 0.00 24 .-__. 0 0 0 42 _-___42_ 7 265 --- 0 6 c)AED emulsion 0 -2 Emelope loss/gain 22 63 584 246 12 a) infiltration 0 0 127 37 b) Room ventilation 0 0 0 0 13 hlemal gabs: Occuparis @ 230 0 0 0 0 AppGmrces/olher 0 0 Subtotal (lures 6 to 13) 22 531 711 282 Less e)demal load 0 0 0 0 Less transfer 0 0 0 0 Redstdbutbn 0 0 0 0 14 Subtotal 22 53 711 282 15 Duct loads 26% 49916 6 26 26% 49'h 183 138 To[al room load 27 80 894 420 Air requiretl (ctm) 1 4 32 19 Calculations awroved bvACCA to meet all requirements of Manual J 81h Ed. -!i.- wrlghis-ore- 2018-Oct-1912:53:22 A5UK "'�' RightSufte@ Universal 211818.0.31 RSUBB101 Page ...ets\Wrightsofl HVAGWARSHALL RES-NAVION DR.rup Cat=MJB Front Doorfaces: S wrightsoftRig W@ Worksheet Job: AHU 1 Date: Oct 19, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCSGAOL.COM 1 Room name STORAGE MASTER BEDROOM 2 Exposed wan 0 It 39.0 it 3 Room heght 10.0 tt h aaf/cool 11.0 It tat/cool 4 Room dimerslors 8.0 x 4.0 it 1.0 x 402.0 It 5 Room area 32-0 tl= 402.0 ft' Ty Construction U-value Or HTM Area number (BIUMt-"F) (BtuMP) or perimeter (0) (Bluh) or perimeter (0) (Btuh) Heat Cool Gross WPIS Heat Cool Gross N/P/S Heal Cool 6 13A-4acs _ .H43 n 4.00 2.19 - -�0 --'---0 0 ^ 0 too 150 601 -- --328 291az1rg, clr low-e 0.650 n 18.20 14.99 0 0 0 0 48 0 874 720 2 glazlrxy cir low-e 0.660 n 18.20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, cir low-e 2glazing drlaw-e_ 0.650 0.650_ n n_ 0.00 __18.20 0.00 .14.99 0 -__0_ 0 ____ 0�___.0 0 0 ___-0._0_0_ 0 0 0 _0._.. 0 -._0 13A-4ocs 2 glazing, cir low-e 0.143 0.650 a a 4.00 18.20 219 33.77 0 0 0 0 0 0 0 0 231 12 219 0 877 218 479 405 2 glazing dr low-e 0.650 a 18.20 33.77 0 0 0 0 0 0 0 0 11D0__________ a Q.____-0 13A-0acs __-0.390_ 0. se _._0.00 4. _ _0.00 9 _ -0 0 _ ____0 0 _____0 0 __. -0 0 ____..0 0 ______0 0 0 0 291azing, drbw-e 0.650650 se 18.2029 17.7.79 0 0 0 0 0 0 0 0 _ -v 29lazing dr,bw-e., _ _0. _se_. -1.0 ._23. _-__.0 0 ..__ 0. ..T-__. _,0_ _... 0. _.0 _-.0 -_ �0 13A-4a0s 0.143143 s 4.000 4 2.19 19 0 0 0 0 0 0 0 0 2glazing cir low-e 2 glazing cir bw-e 0.650 0.650 s s 1&20 18.20 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2glazing, cir bw-e 2 glazing cir low-e 0.650 0.650 s s 1820 18.20 14.99 14,99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing dr bw-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing cir low-e 2 glazing cir low-e 2 glazing cir low-9 0.650 0.650 0.650 s s s 18.20 18.20 18.20 14.99 14.99 14.99 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 -7:tG 20azina-dr bw:e----'--0.650 13A-gabs 0.143 s-----18.20 " sw 4.00 14.99.__ '-- 2.19 -"0-- 0 --_0.---"' 0 -0-- 0 -,_0-_P--------0------0 0 .,,._. 0 0 0 _____0 0 2 glazing dr low-e 0.650 sw 18.20 17.79 0 0 0 0 0 0 0 0 W 2glazing dr.bw:e__ _ 13A-4acs 0.143 _sw w ,-18.20 4.00 - ..23.96 2.19 .... ...0 0 _ _ _. 0 0 0 0 _.._. . 0 0 _.:_ 0._ 0 0 0 _ _.. -0 0 __ .� 0 0 I-G 2 gazing cir low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing dr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 L�GG . , 2oiazinm dr bw e- _. 0.650 w 0.00 0 0 _ 0 .0 .C- 16AJOad___.. _ _ _. 0.032 _ - _ 0.90 __0.00 __ 224 _.. ___.0 _0 _ _ 0.__� ----,a 0 _ _ _ _0 ____0__ _ 356 __o _ -am_ _ _ 319 _. _..._.797 F 22A-tph_. 1.358 - 38,02 0.00 32 0 0 0 402 - w39 1483 _ 0 6 c)AED murslon -1 -20 Emelope IoWgtn 0 -1 4371 2710 12 a) Infiltration 0 0 781 224 b) Rcomlentllation 0 0 0 0 13 Memel gabs: Occlglarts @ mo 0 0 0 0 Applianom/other 100 500 Sudott Tines 6 to 13) 0 99 5152 3434 Less external load 0 0 0 0 Less trarsler 0 0 0 0 Redistribution 0 0 0 0 14 Sutton 0 99 5152 3434 15 Duct loads 1 26%1 499/6 0 48 25% 499/6 1324 1674 Total room load 0 148 6476 1 5108 Air required (of m) 0 7 232 232 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - =Ln_" 'soi 2018.Oct-19 1253:22 RghtSufteO UnNersal 2018 18.0.31 RSUG8101 Page 10 ...ets\Wrightsoft HVACIMARSHALL RES- NAVION DR.mp Cab = MJB Front Door faces: S wrightsoft° Right-JO Worksheet Job: AHU 2 Date: Oct 19, 2018 ay: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Prone: 772-366-6799 Fax 772-466-6796 Email: OUICKCALCSQAOL.COM 1 Room nans AHU 2 STA01S UP 2 Exposed wag 120.8 ft 16.0 ft 3 Room height 9.3 it 14.0 It heat/cool 4 Room dimensions 8.0 x 8.0 ft 5 Room area 11720 fl2 64.0 ft2 Ty Construction U-%due Or HTM Area Am number (8tuhfit-F) (Btuh7F) or perimeter (ft) (BBluh) or perimeter (ft) (Bt�uh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 -13A-9ucs 2 glazing cir low-9 2 glazlrg cir bw-e _._. 0.143 0.650 0.650 n n n y 4.00 0.00 0.00 219 0.00 0.00 182 0 0 - . -i08 0 0 _ _ _ 7T34__ 0 0 72�7 0 0 --'- 0 0 0 0 0 0 --_-lt 0 0 . _To 0 0 - _ 11 2 glazing cir bw-e 2gluIng,drbw_e_ 0.650 -_ 0.650 It - n_ 18.20 .___0.00 14.99 V0.00 - 54 ______5 0 _._ _0,. 976 ______0_.__6 804 0 _.__ 0 0 _ _72 0 _ .__ -.0 0 . ___58 0.650 a 4.00 2.00 130 110 480 250 72 72 280 150 2 glazing 2 glazlrg, clrdr bw-e 0.660 a 0.00 0.00 0 0 0 0 0 0 0 0 2 gla7Jng dr low-e 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 11 DO ___ 13A,4 cs 0.390 -0.143 _e _ so -_ 10.92 0.00 10.34 -0.00 --_ _- 18 -- 0 18 - __ _ 0 _. ,..._ 195 0 18 5 _ -_ . _ 0 _ _ 0 __ 0 0 ...___ -0 0 .�____ 0 0 _..__..__0 _ y4J1 I(��3 2glazlrcy cir lmv-e 2glazirg, clr.bw:e___ 0.650 _.___0.650 se . so 0.00 _._.0.00 0.00 ,. 0.00 0 0 0 -._ _..0 0 __ ---0 0 __ ___ --.0 0 -_.. _ . 0 0 _ ...- 0 0 --- _ o 0 -_ -----0 13A-0ocs 0.143 s 4.00 219 398 368 1485 801 72 72 288 156 2 glazing dr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 gluing dr bw-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing dr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, dr bw-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing cir bw-e 0.650 s 18" 14.99 30 30 546 450 0 0 0 0 2 gluing, dr bw-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazirg cir bw-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2glazing. cir law-e 13A-4acs _ 0.650 -_.-0.143 __s- sw 0.00 _.__ 0.00 __ 0.00 �0.00 0 .. _ ._ ,0 0 _ _.�___0 0 0 _ _ _0 0 ,_ _0 0 _ __... �0 0 __.. __- 0 _ _T._ 0 0 -_.__.___0 2 glazing cir low-e 2 glazing dr bw_e.. or50 _ _ 0.650 sw M. 0.00 ----0.00 0.00 --._0.00 0 .-____0 0 ___0 0 ___ _ 0 0 _ _ _--.0 0 �,__ 0 0 ___ _ -.0 0 _ . -_ __0 0 _ .__.0 W 13A-4acs 0.143 w 4.00 219 388 375 _ 1502 820 0 0 0 0 �G 2glazirg cir bw-e 0.650 w 18.20 33,77 6 0 109 203 0 0 0 0 2glazirg dr low-9 0.650 w 0.09 0.00 0 0 0 0 0 0 0 0 L�GG 2glazing drbw_e_ -_ 0.650, w_ 18.20 33.77 15 0 273 0 0 Q, 16A30•ad - _T -_ 0.032 0.90 _ _--_-2.24 _ j172 _ __ m72 _ ,. _-_ 1050 _ __507 __ _ 2625 . _0. . _ 64 .. .._._0 „64 __ .__ _ ..57 _ _ _ 143 F _ 22A-t0 1.358 - - 0.(?0 0.00 _ 32 _ 0 0 0 32 0 0 0 6 c)AED emurslon 112 -17 Emelope loss/gain 7019 6999 634 442 12 a) H[Itration 1982 569 262 75 b) Rcomlentilalion 0 0 0 0 13 Internal gains: Occuparts 0 230 0 0 0 0 Appliarces/other 4400 500 Subtotal (lines 6 to 13) 9001 11968 896 1017 Less e)derral load 0 0 0 0 Less transfer 0 0 0 0 Rerllsldxlbn 0 0 0 0 14 Subtotal 9001 11958 896 1017 15 Duct loads 2a% 1 14% 2531 1676 28% 14% 252 142 Total room load 1 11531 1 1WA4 1148 1159 Air required (cfm) 627 627 62 53 Calculations awrowd byACCA to meet all requirements of Manual J 8th Ed. -fl&- 2018-Oct-1912.53:22 ,4a UA RghtSuiteR Unimsal 2IB 18-0.31 RSU08101 Page 11 ...ets%Wrightsdl HVAC%MARSHALL RES- NAVION DR.rup Cab = MJB Front Door faces: S wrightsoft' Right-J@ Worksheet Job: AHU 2 Date: Oct 19, 2018 QUICK CALCS, INC. By. 317ST LUCIE LANE, FORT PIERCE, FL3494S Phone:772-466-6799 Fax 772-466-6796 Email: OUICKCALCSQAOL.COM BALCONY CRAFT ROOM A 8.0 It 71.9 It t TRwm 9.0 ft heaVcod 9.0 It heat/cool nslo x; 1.0 x 325.0 ft 325.0 IF 1.0 x 163.5 It 163.5 In Ty Construction number llvelue (Btuh4t -F) Or HTM (BMW) Area or perOF) n ter (It) (Btuh) or perimeter (8) (Btuh) Heat Cool Gross N/P/B Feat Cool Gross N/P/S Heal Cool 6 i3A-9acs -- 0.743 �-n- � -� 4.00 Y 2.tB --0 --- -' p o --0 Q - �� __-M _ -- 219 2 glazing cir low-e 2glazirg, clr low-e 0.650 0.650 n n 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 - 0 0 11 2glaiing, clr low-e 2glazhg, dCbwre.. 0.650 _ _ 0.650 n -n 1&20 _-0.00 14.99 _ 0.00 0 ------ 0 0 _ _ _0 0 _ ---0 0 _ ---0 54 ___ .__0 0 . _ --0-..-- 976 _ 0 804 _ __.._.0 2 glazing dr low-e 2 glazing 2 glazing dr low-9 0.650 0.650 0.650 a a a 4.00 0.00 0.00 0.00 0.00 0.00 36 0 6 18 0 0 73 0 0 40 0 0 0 0 6 0 0 0 0 0 0 0 0 0 .. __ V� 11D0_ __�_ __ _ 13A-400s . _. .0.390 0.143 4e - se . 10.92 0.00 10.34 0.00 _. . 18 0 ----18 0 195 0 _ _ _185 0 ---0 ^ 0 ___ -0. 0 _ _ _._0 0 _ - _ 0 0 2glazing clr low-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 _..r_ 2glazing drlow,c--_ ---' _ 0.650 _se _ _.0.00 '---0.00 _____._0 _ __.' 0 ____--0 _. -----0 ----,-0 _ __O `.__ ..0 . _ "-_0 13A-4003 0.143 s 4.00 Z19 0 0 0 0 0 0 0 0 2 glazlrg, clr bw-e 2 glazing, dr bw-e 0.650 0.650 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazing dr Tow-e 2 glazing, Or low-e 0.650 0.650 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2 glazhg, clr low-9 0.650 s I&20 14.99 0 0 0 0 0 0 0 0 2 glazirg dr low-e 2 glazing dr low-e 2 glazing dr low-e 0.650 0.650 0.650 s s s 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 .__ �j 2otazina dr low-e0-650 13A-4acs 0.143 s__. sw _ 0.00 0.00 --0.00 0.00 -0 0 _... _-0_._�-_.p_-- 0 0 __0 0" p._.__._._0..__ J 0 0 0 0 ---0 �0 f-C �( 2glaziM dr low-e 0.650 sw 0.00 0.00 0 0 0 0 0 0 0 0 2glazing-dr low-e_ _ _ _0.650 _sw_ ..__ 0.00 ---_0.00 �.. __0 0 --_-0 ----.,0 _ -0 _._ _ __.0 .�__ -0 '0 13A-4ocs 0.143 w 4.00 2.19 38 36 144 79 0 0 0 0 2 glazing, olr low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing dr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 __ Q_�.. 2dazinad[low-e _ 18A.10atl ..__. _._ _ _ 0.650 0.032 _w_-_._18.20 ------- ..v_ ._0.00 33.77 _. _0.24.__._320 '- _-_0 -'__-__0 --'----325 ._..0 ____.291 ._. _. _0 _. 720 0 _ .._,180 _._ _0_._-_ .__ 764__360 0 0 F - 22A4ph 1.358 - 0.00 0.00 0 0 0 0 0 0 0 0 61 c) AED exciu slon -65 -30 Emelope loss/gain 703 966 1340 1269 12 a) Wittmtion 131 38 197 56 le) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 3000 500 Subtotal Qlnes 6 to 13) 834 4004 1536 1816 Less ebemal load 0 0 0 0 Lesstrarsfer 0 0 0 0 RecrMilbtbn 0 0 0 0 14 Subtotal 834 4004 1536 1816 15 Duct loads 28% 145/6 235 561 28% 145/6 432 254 Total room load 1009 1 4564 1968 2070 Air required (ef m) 58 210 107 95 Calculations aWroved bvACCA to meet all requirements of Manual J 8th Ed. '*I+- ,w,.,_�t�ti�o, 2018-Oct-19 12:53:22 'p RightSUHe@ Universal 201818.0.31 ASU08101 Page 12 ...ets\Wrightsoft HVAC\MARSHALL RES- NAVION OR.rup Cab = MJB Front Door faces: S wrightsoft• Right-JOWorksheet Job: AHU 2 Date: Oct 19, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724666799 Fax 772466-6796 Email: OUICKCALCSOAOL.COM - t Room name CRAFT W IC W C 4 2 Fposed wall 15.0 it 5.0 it 3 Room height 9.0 it heat/cool 9.0 it heal/cod 4 Room dimensions 6.0 x 9.0 It 6.0 x 5.0 it 5 Room area 54.0 iP 30.0 IF Ty Construction U-%d a Or HrM Area OF) Load Area OF) Load number (BItdAF°F) (BtulvlP) or perimeter (it) (Btuh) or perimeter (1t) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Cool 2 glazing cir low-e 0.650 n 0.00 0.00 - 54 0 -_- 64 0 218 0 - �_-- 718 0 ____0 0 0 0 ____ -0 0 0 0 2 glazirg cir low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing cir low-e 2 glazing dr.low:e - 0.650 --0.650 n _n. 18.20 - _0.00 14.99 _._. 0.00 -0 ___._..0_'_ 0 _0____ 0 _0 0 _.__._0 0 _'__._0 0 ____ 0____ 0 0_ - 0 _0 t}! lL�--GGp 13A-0ocs 2 glazing Gr law-e 2 glazing Clr bw-0 0.65 0.0 650 O.B50 a a a 4.00 0.00 0.00 219 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11D0 _ __. r_- _ 13A-4ocs _ _0.390 0.143 _e se_ 10.92 0.00 __10.34 0.00 _. 0 0 _0 0 0. _-_0 0 0 '- 0 __ 0 -_.__0 0 0 0 -0 2 glazing cir low-e 2glazing cIrbwce_ 0.650 __.0.650 se -se 0.00 _ _.0.00 0.00 ____0.00 0 _ __.._0 0 ._0 0 _._ _0 0 .._ _ 0 0 _. 0 0 ._ ___0 0 _.. 0 0 __0 13A-4ocs 0.143 s 4.00 2.19 0 0 0 0 __. 0 0 0 0 2 gluing, cIr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2glazing cir bw-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2glazing cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing cir low-e 0.650 s 18.20 10.99 0 0 0 0 0 0 0 0 2glaz(rg, cir bw-e 2 glazing, cir low-e 2 glazing, cir low-e 0.650 0.650 0.050 s s s 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 r. - 2olwlna clr-bw_e 0.650 0.00 0 0 0 0 0 0 0 0 73A-40cs . _ __0.143 _s_ sw _ _0.00 0.00 0.00 0 _ 0 0 _0 0 . .-0 .. ..0 - -_ 0 2giazing clrlow-e 0.650 sw 0.00 0.00 0 0 0 0 (1 0 0 0 --. 2glazlrg-drlow:e _ _...0.650 sw -- 0.00 --_. 0.00 0 -. _- .o - _..-0 __0 - 0 _ _0 _.. _ _ 0 _._-_0 73A-4ocs 0.143 w 4.00 2.19 at 91 324 177 45 45 t8o 98 2 glazlrg, cir low-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing cir low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 _. 201azina Grimv_e 18.20 0 0 0 0 0 _. 16AAM _ .. .-0.650-w- _.__1.358 -.. _ - .._ 0.90 _33.77 _.�2.24 __. _._54 ___.__0 ?0 _ _ a40 121 __...__. _30 _ _ _.0 _..30 .___. __.20 _0 .__.__80 F _ 22A-tph -1.358 0.00 0.00 0 0 0 0 0 0 0 0 6 c)AED excursion -8 3 Emelope loss/gain 589 409 207 163 12 a) Wiftratlon 246 71 82 24 b) Roomtemilation 0 0 0 0 13 tdemll gains: Oocuparts 0 230 0 0 0 0 Appflarlces/other 0 0 Subtotal Ones 6 to 13) 835 479 289 186 Less wderrel load 0 0 0 0 Less transfer 0 0 0 0 ReWdMlbn o 0 0 0 14 Subtotal 835 479 289 186 15 Duct loads 2W. 140/6 235 67 28% 14% 81 26 Total room load 1069 546 370 212 Air reglilrad (olm) 58 25 20 10 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. C -rk- =:Lan != 2018-Oc1-191253:22 RightSufteO Universal 201818.0.31 RSU08101 Page 13 ...ets%Wrightscft HVACWARSHALL RES- NAVION DR.mp Cab = MJB Front Door feces: S I�+ wrightsoft^ Right-J@ Worksheet Job: AHU 2 Date: Oct 19, 2018 QUICK CALLS, INC. By- 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Emil: OUICKCALCS(PAOL.COM 1 Room name B®ROOM 4 BATH 3 2 Bposed wall 25.0 it 10.9 1t 3 Room height 9.0 1t heaf/cool 9.0 1t heat/cool 4 Room dimensions 12-0 x 13.0 it 1.0 x 125.5 it 5 Room area 156.0 fP 125.5 IF Ty Construction t)-%slue Or HTM Area (1P) Load Arai 0P) Load number (Btuhlt-F) (BIUMP) or perimeter (0) (Btuh) or perimeter (it) (Btuh) Heat Cool Gross WP/9 Heal 0001 Gross WKS Heat Cool e - 13A-gocs 0:143 ___ n _- 4.00 _ � 2.16 _ .. O - __ __ O __._ _ U __ --'--o . _ _ _ _. b ___ U ___ ._ 0 . b 2 glazing, dr low-e 2 glazing, clr low-e 0.650 0.650 n n 0.00 Moo 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11 2 glazing clr low-9 2glazirlg.clrbw-e_. 0.650 _ _ 0.650- n n_ 18.20 ___0.00 14.99 _-_0.00 0 -_ --. 0 0 _ _ 0 0 -_0- 0 _ 0 _ _0 0 0 0 . _ _ 0 0 _ ll}y� MA-400S 0.143 a 4.00 2.19 0 0 0 0 0 0 0 0 (--G 2 glazing, dr low-e 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 2glazing or low-e 0.650 a O.W 0.00 0 0 0 0 0 0 0 0 L�_Gp I� 11D0__,..__0.390_e_10.92_10.34._.0___.__0'-_---0 13A-0ocs 0,143 se 0.00 0.00 0 0 0 0 0 .___0 0 _ _ ___0 0 0 0 0 0 I--G 2gluing cir tow-e 0.650 se 0.00 0.00 0 0 0 0 0 0 0 0 -.--GG 2glazlrg,dr bwre . - -----0.650 se __..0.00 ._._0.00. .__ _0 __. _ 0.._..____-o _.. 0 ___ 0- 0 _-0 _. _. _ 0 13A-4ocs 0.143 s 4.00 2.19 108 108 432 236 _ 99 99 _ 396 217 2 glazing, Gr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing air low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing or low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing clr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing dr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing or low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 _-77G 2dazinq Grbw_e_____0.650 0.00 0 0 0 0 0 0 0 0 13A-4acs 0.143 _s__T0.00 sw 0.00 _,_ 0.00 _0 0 _ _. __. 0 _0_..._ _0 -0 ___-___0 .__.-0 T= 2 glazing, clr low-e 0.650 sw 0.00 0.00 0 0 0 0 0 0 0 0 2gla71ng,clr.bw7e.__ 13A-4ocs _ 0.610_Sw.___0.00 0.143 w 4.00 -__0.00 2A9 _0__._0-T__-_0._ 117 96 384 _._ 0 210 _.,_0__ 0 0 _.0 0 0 --� 2 glazing clr low-e 0.650 w 18.20 33.77 6 0 109 203 0 0 0 0 2 glazing dr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2 dazhlgdr low-e_____ w_.__ 18.20_ 33.77 15__.-.__ 0____273 507 0..___ 0 0 C ._ _ _ F 16ASOad __-.. . _ _ 22Aiph _0.650 _ _ 0.032 1,358 _ ...._0.90 - 0.00 ._ __ 2.24 0.00 ._ _ 156 0 _ . 156 0 .._.140 0 _ . _ 349 0 ..0 _ .. _ 126 0 _ _ _ 126 0 - 112 0 _ _.. 281 0 6 c)AED excursion 276 -9 Emelopa loss/gain 1339 1781 509 489 12 a) Wilhation 409 118 180 52 b) Roomtemilation 0 0 0 0 13 Internal gabs: Oocuparts 0 230 0 0 0 0 Appliances/other 0 0 Subtotal 0(1es 6 to 13) 1748 1899 689 541 Less exdernal load 0 0 0 0 Less transfer 0 0 0 0 ReWrIblllon 0 0 0 0 14 Subtotal 1748 1899 689 641 15 Duct loads 28% 14% 492 266 28°/, 14% 194 76 Total room load 1 2240 1 2164 883 616 Alr required (of m) 122 99 48 28 Calculations awroved bvACCA to meet all requirements of Manual J 8th Ed. -ff&- wrighCsofe' 201e-0cF191253:22 RghlSudeg Unio al 20181&0.31 RSU08101 Page 14 ...es\Wrightsoft HVAC\MARSHALL RES- NAVION DR.rup Cato = MJB Front Door faces: S I}� wrightsoft' Right-J® Worksheet Job: AHU 2 Date: Oct 19, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LAW, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-4666796 Email: OUICKCALCS(RAOL.COM 1 Room name TOILET WIC 3 2 Exposed wag o It 0 It 3 Room heght 9.0 1l heat/cool 9.0 ft heat/cod 4 Room croensions 5.0 x 3.0 ft 5.0 x 5.0 tt 5 Room area 15.0 W 25.0 ft2 Ty Construction LLvelue Or HTM Aree Qt2) Load Area QP) Load number (13tuh4F-F) (BtuhAt2) or perimeter (ft) Pull) or perimeter (0) (Bluh) Heat Cool Gross wP/8 Heat Cool Gross WP/S Heat Cool 6 - �.._ 13A-4ocs 2glazirxy cir bw-e -0.143 0.650 - n n ��. 4.00 0.00 - -2.78 0.00 .00 0 0 .� -_,0 0 _ 0 0 U 0 0 0 0 0 _ _0 0 2glazing clr low-e 0.650 n 0.00 0.00 0 0 0 0 0 0 0 0 11 2glazing, clr low-e 2 glazing cir bw-e _ _ 0.650 . 0.650 n _ n_ 18.20 _ _ 0.00 14.99 _ - 0.00 0 _ _ _0 0 _._ _ 0 0 .____ _ 0 0 _. . 0 0 . _ _ „0 0 . -----0 0 - - 0 0 -. - _0 _ 13A-40cs 2glazing dr bw-e 2glazing dr bw-e 0. .650650 0.e50 a a a 4.00 0.00 0.00 219 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 11D0 _ - _ 13A40cs _-_0.390 0.143 a se 10.92 0.00 10.34 0.00 _ ._ 0 0 ._0 0 -__..__0 0 _. __ 0 0 _ _ 0 0 0 0 -._. .__ 0 _...._A 0 _ 2 glazing cir low-e 2g dr.bw a _.._ 0.650 ____0.650-se__.0.00 se 0.00 0.00 ._ 0.00_ 0 _-_0 0 ____0 0 .0 0 ____ 0__.__.0 0 0 -__..0 0 0 0 __0 13A-400a;4acs 0.143 s 4.00 2.19 0 0 0 0 0 0 0 0 2glazing, dr law-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2glazing clr low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing clr law-e 2glazing dr law-e 0.650 0.650 s s 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2glazirn dr low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing dr law-e 2 glazing dr low-e 2 glazing, cir low-e 0.650 0.650 0.650 s s s 0.00 0.00 0.00 0.00 0.00 0.00 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 2(lazino, drbw-e.. 0 _-._ 0 0-.-- _.0 _. _._0. 0 _.. _ 0 -_.. _ 13A4ocs __-0.650 0.143 _ _s_ sw ___0.00 O.00 ___.0.00 0.00 _0 0 _ 0 0 0 0 0 0 0 2 glazing cir bw-e 0.650 sw 0.00 0.00 0 0 0 0 0 0 0 0 _ 2glazing cirbw-e. _ -__0.650 sw_ _. 0.01 .,.0,00 _ _ 0 -__0 __.. .__0 0 0.. _0 -0 __. . -0 73A-4ocs 0.143 w 4.00 2-19 0 0 0 0 0 0 0 0 2glazing clrbw-e 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazlM dr low-e 0.650 w 0.00 0.00 0 0 0 0 0 0 0 0 2dazinri chbw--e _ 0.650 Y. 18.20 _._0 0 _0 - _,_.___0 __ _ _0 _ _.._0 _� C__ _ _ _ - _0.032 _- _ _ -.0.90 _33.77 -- 224 ___r._ _0 __ __15 _ _ __.. 15 ____0 __.. 13 . 34 ___._ _ _ -25 _ _._25.__ 22 _ _56 F _ - - 22A4ph - _- 1.358 - 0.00 0.00 0 0 0 0 0 0 0 , _ 0 6 c)AED excursion .1 -1 Bmlope loss/gain 13 33 22 55 12 a) KlOmtion 0 0 0 0 b) Roomventilaticn 0 0 0 0 13 Kemal gains: Occupants (9 230 0 0 0 0 Applanaes/other 0 0 Subtotal Qlnes 6 to 13) 13 33 22 55 Less ex¢errel load o 0 0 0 Less transfer 0 0 0 0 RedgldbLLion 0 0 0 0 14 Sublolal 13 33 22 55 15 Duct loads 28% 14% 4 5 28% 140/6 8 8 Total room load 17 38 29 63 Air required (cfm) 1 2 2 3 Calculations awroved bvACCA to meet all reauirements of Manual J 8th Ed. -4 - wrY9r+csof!- 2018-Oct-1912:53:22 " RIghtSurtc,8 Universal 2D18 18.0.31 RSUD8101 Page 15 ...ets\Wrightso0 HVAC\MARSHALL RES- NAVION DR.rup Cab = MJB Front Door laces: S wrightsoft' Right-J® Worksheet Job: AHU 2 Date: Oct 19, 2018 By: QUICK CALCS, INC. 317 ST LUCIE LANE. FORT PIERCE, FL 34946 Phone: 772A66-6799 Fa c 772-466.6796 Email: OUICKCALCS®AOL.COM 1 Room name BEDROOM 3 2 Elposcd wall 29.0 It 3 Room helght 9.0 It head/cool 4 Room tlimensions 1.0 X 214.0 it 5 Room Brea 214.0 IF Ty Construction Uvdlue Or HrM Area Load number (Btuhllt °F) (BIUMF) or perimeter (0) (Btuh) or perimeter Heat Cool Grass N/P/S Heat Cool Gross N/P/S Heal Cool 6 ttt}}}III (--G 13A-0bcs -- "- - - - o-f45 - n a.oli --- z.1s -- -- --o - - o --- o - - - a ----- - - irXj 29la clr low-e 0.650 n 0.00 0.00 0 0 0 0 �---GG 291azlrXi ing clr low-e 0.650 n 0.00 0.00 0 0 0 0 I(�; 2glazinKj clr low-e 291azing clr.bwre_._ 0.650 _ 0.650 n __n 18.20 ..__0.00 14.99 .._.0.00 0 ---0 0 _ _ _ _0 0 _ __-_ 0 0 ... __0._. 13A-flocs 0.143 a 4.00 2.19 27 27 108 59 2glazing, clr low-e 0.650 a 0.00 0.00 0 0 0 0 2 glazing clr low-e 0.650 a 0.00 0.00 0 0 0 0 11D0__ _ -_e_ 10.92 10.34 0______0 0______- - .___ _ 13A-0acs ___0.390 0.143 se 0.00 _. 0.00 _0 0 -. 0 0 _ _ 0 2glazing clr bw-e 0.650 se 0.00 0.00 0 0 0 0 2 glazing cir low-e _ .. _0.650 _.se. 0.00 __ 0.00 . - 0 -117 0 ---0 ,- _ 0 -_ 13A-0acs 0.143 s 4.00 2.19 87 348 190 291MIM dr bw-e 0.650 s 0.00 0.00 0 0 0 0 291azing clr low-e 0.650 s 0.00 0.00 0 0 0 0 291azing clr low-e 0.650 s 0.00 0.00 0 0 0 0 291azin-4 dr bvn-e 0.650 s 0.00 0.00 0 0 0 0 2glazing clr IDw-e 0.650 s 18,20 14.99 30 30 546 450 2glazing cir low-e 0.650 s 0.00 0.00 0 0 0 0 2glazing dr low-e 0.650 s 0.00 0.00 0 0 0 0 2 glazing clr low-e 0.650 s 0.00 0.00 0 0 0 0 2 olazinq.clr low_e 0.650 0.00 0.00 0_ 0 1¢' 13A-4ocs _. 0.143 _s_ sw _ 0.00 _ 0.00 _ _-0 0 0 0 -__ _ .0 0 I--C ll� 2glazing dr low-9 0.650 SW 0.00 0.00 0 0 0 0 29lazing cl -low-e _ _ 0.650 -sw -0.00 0.00 0 - -0 . _._ - 0 - 0 _ --CGG 13A-loos 0.143 W 4.00 2.19 . 117 _ 117 468 - 256 2 glazing dr low-9 0.650 W 1&20 33.77 0 0 0 0 2 glazing cir low-e 0.650 w 0.00 0.00 0 0 0 0 2 glazin4 cir bw_e 18.20 33.77 0 0 0 C_. - 1HA30atl__ _. _ _0.650 _ 0.032 -W - _ - - - 0.80 -- _2.24 _ --- ---0 - - 214 - - -, _ __ 214 _ _._ - _-..192 _ -- _ 479 ___ -- - - - - F 22A-Iph. - 1.358 - 0.00 -_ _0_00 0 0 0 0_,- 6 0)AED e1cUMIM -32 Envelope loss/gain. 1663 1403 12 a) WlBrallon 475 136 b) Roomlentilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appfiarces/other 400 Subtotal (Ilres 610 13) 2138 19W Less eAemal Iced 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 2138 1939 15 Duct loads 2W. 141/6 601 272 Total room load I 2739 2211 Air required (cfm) 149 102 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed. - wrY9F+tso`i'!- . A ...01 2018-0ct-191253.22 ets\WrigMsoB HVAC\MARSHALL RES- NAIAON Universal Calc = MJ8 Front Door faces: S Page 16 - wrightsofts Duct System Summary AHU1 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone. 772-466-6799 Fax 772A66-6796 EmaiC OUICKCALCS@AOL.COM Project• • For: MARSHALL RESIDENCE, PACE 2000, INC. NAVION DRIVE, PORTST LUCIE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heat! ng 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/1OM 1600 cfm Job: Date: Oct 19, 2018 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 1600 cfm 248 ft Name Design (Btuh) Htg (cfm) Gig (cfm) Design FR Diam (in) H x W (in) Duct Mat[ Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 1364 49 44 1.000 6.0 Ox 0 VIFx 27.8 115.0 sit BEDROOM 2 h 4455 160 132 1.000 7.0 Ox0 VIFx 26.0 115.0 sti DINING ROOM c 2706 117 123 1.000 7.0 Ox0 VIFx 26.4 115.0 st2 FOYER h 4152 149 91 1.000 7.0 Ox0 VIFx 38.1 135.0 st6 GREAT ROOM h 7380 265 164 1.000 8.0 Ox0 VIFx 39.9 135.0 st5 GREATROOM-A h 7380 265 164 1.000 8.0 OXO VIFx 42.1 135.0 st5 HIS WIC h 894 32 19 1.000 5.0 Ox0 VIFx 55.6 155.0 st7 KITCHEN c 2219 0 101 1.000 7.0 Ox0 VIFx 20.6 115.0 st2 KITCHEN -A c 2219 0 101 1.000 7.0 OXO VIFx 19.9 115.0 st2 LAUNDRY c 1479 0 67 1.000 6.0 Ox0 VIFx 25.8 115.0 st1 M BATH c 1829 68 83 1.000 6.0 Ox0 VIFx 68.7 175.0 st8 M TOILET c 80 1 4 1.000 4.0 Ox0 VIFx 54.4 155.0 st7 M WIC h 2375 85 50 1.000 6.0 Ox0 VIFx 70.8 175.0 st8 MASTER BEDROOM h 3238 116 116 1.000 7.0 OXO VIFx 66.7 155.0 st7 MASTER BEDROOM -A h 3238 116 116 1.000 7.0 Ox0 VIFx 55.7 155.0 st7 OFFICE c 2276 89 103 1.000 7.0 Ox0 VIFx 73.1 175.0 st8 OFFICE -A c 2276 89 103 1.000 7.0 Ox0 VIFx 68.4 175.0 SIB PANTRY c 148 0 7 1.000 4.0 Ox0 VIFx 21.0 115.0 st2 POWDER c 139 2 6 1.000 4.0 Ox0 VIFx 70.3 175.0 St8 STORAGE c 148 0 7 1.000 4.0 Ox0 VIFx 38.1 135.0 st6 .� * Wrightsof - 2018-Oct-191253:26 �•� •�•••� �=--.m.-+ RightSudeO Universa1201818.0GI RSU09107 ��Page 7 ...ets\WrigMsoft HVAC\MARSHALLRES-NAVION DR.rup Ca1c=MJ8 Front Door faces: S Name Trunk Type Htg (cfm) Clg (cfm) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st8 Peak AVF 332 346 1.000 634 10.0 0 x 0 VinlFix st7 st7 Peak AVF 597 600 1.000 765 12.0 0 x 0 VinlFlx st6 st6 Peak AVF 746 698 1.000 809 13.0 0 x 0 VinlFlx st2 st2 Peak-AVF 862 1029 1.000 839 15.0 0 x 0 VinlFlx st5 Peak AVF 529 328 1.000 970 10.0 0 x 0 VinlFlx sit sit Peak AVF 738 571 1.000 939 12.0 0 x 0 VinlFlx Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mail Trunk rb2 Ox0 1600 1600 0 0 0 0 Ox 0 VIFx Wrightsof - 2018-Oct-1812:53:26 RlghtSude® Universal 201818.0.31 RSU08101 Paget Al+Lh ...ets\Wrightson HVAMMARSHALL RES- NAVION DR.mp Calc = MJ8 Front Door faces: S -�- wrightsoft9 Duct System Summary AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Plane: 772-466-6799 Fax 772-46666796 Email: OUICKCALCS®AOL.COM e-roject intormation For: MARSHALL RESIDENCE, PACE 2000, INC. NAVION DRIVE, PORTST LLICIE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heat! ng 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm Job: Date: Oct 19, 2018 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm 174 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) H x W (in) Duct Matt Actual Ln (ft) Ftg.Eciv Ln (ft) Trunk BALCONY c 2282 29 105 1.000 7.0 0x0 VIFx 6.4 115.0 st3 BALCONY -A c 2282 29 105 1.000 7.0 Ox0 VIFx 5.8 115.0 st3 BATH h 883 48 28 1.000 5.0 Ox0 VIFx 15.5 115.0 st4 BEDROOM h 2739 149 102 1.006 7.0 OxO VIFx 18.2 115.0 st4 BEDROOM 4 h 2240 122 99 1.000 7.0 Ox0 VIFx 38.1 135.0 st9 CRAFT ROOM h 1968 107 95 1.000 7.0 Ox0 VIFx 39.1 135.0 st9 CRAFTWIC h 1069 58 25 1.000 5.0 Ox0 VIFx 39.0 135.0 st9 STAIRS UP h 1148 62 53 1.000 6.0 Ox0 VIFx 9.8 95.0 TOILET c 38 1 2 1.000 4.0 Ox0 VIFx 16.7 115.0 s14 wlc3 c 63 2 3 1.000 4.0 Ox0 VIFx 14.8 115.0 st4 WIC h 370 20 10 1.000 4.0 Ox0 VIFx 38.1 135.0 st9 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st9 Peak AVF 307 229 1.000 695 9.0 0 x 0 VlnIFIX st4 st4 PeakAVF 506 364 1.000 928 10.0 0 x 0 VIniFIX st3 Peak AVF 58 210 1.000 601 8.0 0 x 0 VlnlFlx .� -Pk wrightmoft- 2018-Oct-1912:53:26 r� •w�• ��. RghtSude® Universal 20181&0.31 RSU08101 Page ...ets\Wrightsoft HVAC\MARSHALL RES- NAVION DR.rup Cale = MJB Front Door faces: S Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 627 627 0 0 0 0 Ox 0 VIFx Wrightsof - 2019-0ct-1912:53:25 �. �—.�, RighlSude® Universal 201818.0.31 RSU08101 �� Page 4 ...e[s\WrigMsoR HVAC\MARSHALL RES- NAVION DR.rup Calc = MJB Front Doorfaces: 5 This document was created with Win2PDF available at http://www.win2pdf.com. The unregistered version of Win2PDF is for evaluation or non-commercial use only. This page will not be added after purchasing Win2PDF.