HomeMy WebLinkAboutENERGY EFFICIENCY CODERECEIV77D JUN 201017 FORM R405-2014 1ro y I FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: GOTTI RESIDENCE Builder Name: Street:_ 4600 GRADY DRIVE SCANNED Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, BY Permit Number: Owner: GOTTI Jurisdiction: Design Location: FL, Fort Pierce St. Lucie County County:: ST. LUCIE COUNTY (Florida Climate Zone 2 ) • 1. New construction or existing New (From Plans) 9. Wall Types (1364.4 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Frame - Wood, Exterior R=19.0 1354.40 ft2 b. N/A R= ft2 3. Number of units, if multiple family 1 c. WA R= ft' 4. Number of Bedrooms 2 d. WA R= ft2 5. Is this a worst case? No 10. Ceiling Types (1280.0 sqft.) Insulation Area a. Roof Deck (Unvented) R=20.0 1280.00 ft' 6. Conditioned floor area above grade (ft') 1280 b. N/A R= ft' Conditioned floor area below grade 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(173.0 sqft.) Description Area a. U-Factor: Dbl, U=0.65 173.00 ft2 SHGC: SHGC=0.25 b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 9.0 SEER:18.00 b. Central Unit 9.0 SEER:18.00 c. U-Factor: N/A ft2 2 additional cooling systems (see details) SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft. a. Electric Heat Pump 9.0 HSPF:8.50 SHGC: b. Electric Heat Pump 9.0 HSPF:8.50 Area Weighted Average Overhang Depth: 7.688 ft. 2 additional heating systems (see details) Area Weighted Average SHGC: 0.250 14. Hot water systems a. Propane Cap: 40 gallons 8. Floor Types (1280.0 sqft.) Insulation Area EF: 0.590 a. Raised Floor R=11.0 1280.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.135 Total Proposed Modified Loads: 39.98 PASS Total Baseline Loads: 49.25 1 hereby certify that the plans and specifications covered by Review of the plans and f2tiE ST9 j this calculation are in compliance with the Florida Energy specifications covered by this Code. calculation indicates compliance °'F 'j with the Florida Energy Code. y�',,, 4ry h5'." PREPA D Y' M_A_2H"UXWBefore construction is completed r DATE: this building will be inspected for compliance with Section 553.908 0 Jry n I hereby certify that this buildin as designed, is in compliance Florida Statutes. lt, with the Florida Energy de Cbb WE OWNER/AGENI BUILDING OFFICIAL: DATE: - DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.2.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with ]wand an envelope leakage test report in accordance with R402.4.1.2. -`(C co ,_ 6/23/2017 10:15 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2014 PROJECT Title: GOTTI RESIDENCE Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1280 Lot # Owner. GOTTI Total Stories: 1 Block/SubDivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: 4600 GRADY DRIVE Permit Office: ST.-LUCIE COUNTY Cross Ventilations No County: ST. LUCIE COUNTY Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 UNIT 1 320 3008 2 UNIT2 336 3158.4 3 UNIT3 320 3008 4 UNIT4 304 2812.8 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 1 136 1278.4 No 2 1 1 Yes Yes Yes 2 WIC 1 44 413.6 No 0 1 Yes Yes Yes 3 BATH 1 96 902.4 No 0 1 Yes Yes Yes 4 HALL. 44 413.6 No 0 1 No Yes Yes 5 GREAT ROOM 336 3158.4 No 1 1 Yes Yes Yes 6 BEDROOM 2 136 1278.4 No 2 1 1 Yes Yes Yes 7 BATH 2 96 902.4 No 0 1 Yes Yes Yes 8 WIC 2 44 413.6 No 0 1 Yes Yes Yes 9 HALL 44 413.6 No 0 1 No Yes Yes 10 KITCHEN 192 1804.8 Yes 2 1 Yes Yes Yes 11 GREAT 112 1008 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Raised Floor BEDROOM 1 __ __ 136 ft' 11 0 1 0 2 Raised Floor WIC 1 _ — 44 ft' 11 0 1 0 3 Raised Floor BATH 1 96 ft' 11 0 1 0 4 Raised Floor HALL 44 ft' 11 0 1 0 6/23/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2014 FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 5 Raised Floor GREAT ROOM _- __ 336 ft' 11 0 1 0 6 Raised Floor BEDROOM 2 ___ _- 136 ft2 11 0 1 0 7 Raised. Floor .BATH 2. _- 96 ft2 11 0 1. 0. 8 Raised Floor WIC 2 ____ -_ 44 ft' 11 0 1 0 9 Raised Floor HALL ____ ___ 44 ft2 11 0 1 0 1 ORaised Floor KITCHEN ____ ___ 192 ft2 11 0 1 0 11Raised Floor GREAT __ __ 112 ft2 11 0 1 0 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1422 ft2 224 ft2 Light 0.6 No 0.9 No 20 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Unvented 0 1349 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Unvented) BEDROOM 1 20 Blown 136 ft2 0.1 Wood 2 Under Attic (Unvented) WIC 1 20 Blown 44 ft2 0.1 Wood 3 Under Attic (Unvented) BATH 1 20 Blown 96 ft2 0.1 Wood 4 Under Attic (Unvented) HALL. 20 Blown 44 ft2 0.1 Wood 5 Under Attic (Unvented) GREAT ROOM 20 Blown 336 ft' 0.1 Wood 6 Under Attic (Unvented) BEDROOM 2 20 Blown 136 ft2 0.1 Wood 7 Under Attic (Unvented) BATH 2 20 Blown 96 ft' 0.1 Wood _ 8 Under Attic (Unvented) WIC 2 20 Blown 44 ft' 0.1 Wood 9 Under Attic (Unvented) HALL 20 Blown 44 ft' 0.1 Wood 10 Under Attic (Unvented) KITCHEN 20 Blown 192 ft2 0.1 Wood 11 Under Attic (Unvented) GREAT 20 Blown 112 ft2 0.1 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 S Exterior Frame - Wood BEDROOM 1 19 17 0 9 5 160.1 ft2 0 0.25 0.6 0 2 W Exterior Frame - Wood BEDROOM 1 19 8 0 9 5 75.2 ft2 0 0.25 0.6 0 3 S Exterior Frame - Wood WIC 1 19 11 0 9 5 103.4 ft2 0 0.25 0.6 0 4 E Exterior Frame - Wood BATH 1 19 8 0 9 5 75.2 ft2 0 0.25 0.6 0 5 S Exterior Frame - Wood BATH 1 19 12 0 9 5 112.8 ft2 0 0.25 0.6 0 6/23/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo w Space 1. 6 W Exterior Frame - Wood GREAT ROO 19 16 0 9 5 150.4 ft2 0 0.25 0.6 0 7 N Exterior Frame - Wood BEDROOM 2 19 17 0 9 5 160.1 ft2 0 0.25 0.6 0 8 W Exterior Frame - Wood BEDROOM 2 19 8 0 9 5 75.2 ft2 0 0.25 0.6 0 9 N Exterior Frame - Wood BATH 2 19 12 0 9 5 112.8 ft2 0 0.25 0.6 0 10 E Exterior Frame - Wood BATH 2 19 8 0 9 5 75.2 ft2 0 0.25 0.6 0 11 N Exterior Frame - Wood WIC 2 19 11 0 9 5 103.4 ft2 0 0.25 0.6 0 12 E Exterior Frame - Wood KITCHEN 19 16 0 9 5 150.7 ft2 0 0.25 0.6 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 E Insulated KITCHEN None .39 3 7 21 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 W 2 Metal Low-E Double Yes 0.65 0.25 41.0 ft2 8 ft 0 in 1 ft 4 in None None 2 W 6 Metal Low-E Double Yes 0.65 0.25 82.0 ft2 8 ft 0 in 1 ft 4 in None None 3 W 8 Metal Low-E Double Yes 0.65 0.25 41.0 ft2 8 ft 0 in 1 ft 4 in None None 4 E 12 Metal Low-E Double Yes 0.65 0.25 9.0 ft2 2 ft 0 in 1 ft 4 in None None INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000417 1398.5 76.78 144.39 .3041 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Duds 1 Electric Heat Pump Split HSPF:8.5 9 kBtulhr 1 Ductless 2 Electric Heat Pump Split HSPF:8.5 9 kBtulhr 2 Ductless 3 Electric Heat Pump Split HSPF:8.5 9 kBtulhr 3 Ductless 4 Electric Heat Pump None HSPF:8.5 9 kBtu/hr 4 Ductless COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 18 9 kBtu/hr cfm 0.7 1 Ductless 2 Central Unit Split SEER: 18 9 kBtu/hr cfm 0.7 2 Ductless 3 Central Unit Split SEER: 18 9 kBtu/hr cfm 0.7 3 Ductless 4 Central Unit None SEER: 18 9 kBtu/hr 270 cfm 0.7 4 Ductless 6/23/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2014 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane None KITCHEN 0.59 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector .Storage Carl # Company Name System Model # Collector Model # Area Volume FEF None None ft' TEMPERATURES Programabl[e Ceiling Fans: an Heat ng pq Jan [X] Feb Mar Mar Apr May 11 [X] Jun [ ]Jul X� 4 ]Aug [X] [ ]Sep [ ][XOct]] L J Oct Nov [rX'� Venting [ I Jan [) Feb X Mar Jun [) Jul [) Aug [ ) Sep lxl [X] [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 6/23/2017 10:16 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5 FORM R405-2014 TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: GOTTI RESIDENCE Builder Name: Street: 4600 GRADY DRIVE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: GOTTI Jurisdiction: Design Location: FL, Fort Pierce COMPONENT CRITERIA CHECK Air barrier and thermal barrier A continuous air barrier shall be installed in the building envelope. Exterior thermal envelope contains a continuous barrier. Breaks orjoints in the air barrier shall be sealed. Air -permeable insulation shall not be used as a sealing material. Ceiling/aftic The air barrier in any dropped ceiling/soffit shall be aligned with the insulation and any gaps in the air barrier shall be sealed. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Corners and headers shall be insulated and the junction of the foundation Walls and sill plate shall be sealed. The junction of the top plate and the top or exterior walls shall be sealed. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Knee walls shall be sealed. Windows, skylights and doors The space between window/doorjambs and framing and skylights and framing shall be sealed. Rim joists Rim joists are insulated and include an air barrier. Floors (including above -garage Insulation shall be installed to maintain permanent contact with underside and cantilevered floors) of subfloor decking. The air barrier shall be installed at any exposed edge of insulation. Crawl space walls Where provided in lieu of floor insulation, insulation shall be permanently attached to the crawlspace walls. Exposed earth in unvented crawl spaces shall be covered with a Class I vapor retarder with overlapping joints taped. Shafts, penetrations Duct shafts, utility penetrations, and flue shaft openings to exterior or unconditioned space shall be sealed. Narrow cavities Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall be airtight, IC rated, and sealed to the drywall. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind piping and wiring. Shower/tub on exterior wall Exterior walls adjacent to showers and tubs shall be insulated and the air barrier installed separating them from the showers and tubs. Electrical/phone box on The air barrier shall be installed behind electrical or communication boxes or air sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Fireplace An air barrier shall be installed on fireplace walls. Fireplaces shall have gasketed doors 6/23/2017 10:16 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 81 The lower the EnergyPerformance Index, the more efficient the home. 4600 GRADY DRIVE, FT. PIERCE, FL, ' 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (ft' 7. Windows" Description a. U-Factor: Dbl, U=0.65 SHGC: SHGC=0.25 b. U-Factor: N/A SHGC: c. U-Factor: N/A SHGC: d. U-Factor. N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Raised Floor b. N/A c. N/A New (From Plans) Single-family 1 2 No 1280 Area 173.00 ft' ft' ftz ft' 7.688 ft. 0.250 Insulation Area R=11.0 1280.00 ft' R= ft' R= ft' 9. Wall Types a. Frame - Wood, Exterior b. N/A c. N/A d. N/A 10. Ceiling Types a. Roof Deck (Unvented) b. N/A c. N/A 11. Ducts 12. Cooling systems a. Central Unit b. Central Unit 2 additional cooling systems 13. Heating systems a. Electric Heat Pump b. Electric Heat Pump 2 additional heating systems 14. Hot water systems a. Propane b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code commgiant features. Builder Signature: ly_- Date: Ds..c-;tS zo/ 17 Address of New Home: 140)MDA 1 1,42 City/FL Ltl�/J Insulation R=19.0 R= R= R= Insulation R=20.0 R= R= Area 1354.40 ft' ft' ft' ft' Area 1280.00 fP ft' ft' R ft' kBtu/hr Efficiency 9.0 SEER:18.00 9.0 SEER:18.00 (see details) kBtu/hr Efficiency 9.0 HSPF:8.50 9.0 HSPF:8.50 (see details) Cap: 40 gallons EF: 0.59 Pstat 'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 6/23/2017 10:15 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1 Project Job: t S -F wrightsoft° i SCANNED By: Ju119,2015 Entire House BY r QUICK CALCS, INC. St. Lucie Count Phone: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 772-466-6799 Fax 772-4GSG796 Email: QUICKCALCS� L.COM Project Information For: GOTTI RESIDENCE .00 GRADY DRIVE,• s t ! C41%0% Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Outside db 42 OF Inside db 70 OF Design TD 28 OF Heating Summary Structure 14247 Btuh Ducts 2557 Btuh Central vent (24 cfm) 741 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 17545 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatingg Coolingg Area (ft2) 1280 1280 Volume (ft3) 12032 12032 Air changes/hour 0.45 0.23 Equiv. AVF (cfm) 90 46 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 5.1 kW 17448 Btuh 27 OF 597 cfm 0.036 cfm/Btuh 0 in H2O Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TO 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 8945 Btuh Ducts 4299 Btuh Central vent (24 cfm) 397 Btuh Blower 0 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Equipment sensible load 12959 Btuh Latent Cooling Equipment Load Sizing Structure 2527 Btuh Ducts 1293 Btuh Central vent (24 cfm) 1005 Btuh Equipment latent load 4825 Btuh Equipment total load 17784 Btuh Req. total capacity at 0.70 SHR 1.5 ton Cooling Equipment Summary Make Trane Trade TRANE Cond 4TTR6018B1 Coil TEM6AOB24H21++TDR AHRI ref 7567552 Efficiency 13.0 EER, 16 SEER Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 12530 Btuh 5370 Btuh 17900 Btuh �597 cfm �(),045 cfm/Btuh LL�lC00 , 0 in H2O �® Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wri hf Soft 2016-Jul-2008:48:08 9 Right-SuReO universal 201717.0.03 RSU08101 Page 1 ACM C: UserslQuick CaIcskDocuments1GOT1-1 RESIDENCE.mp Cale = MA From Door faces: N F wrightsoft Right-M Worksheet Job: Entire House Date: Jul 19, 2016 8y: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM 1 Room name Entire House BEDROOM 1 2 Exposed wall 144.0 ft 25.0 ft 3 Room height 9.4 ft d 9.4 ft heat/cool 4 Room dimensions 8.0 x 17.0 ft 5 - Room area 1280.0 ft' 136.0 fN Ty Construction U-value Or HTM Area (ftj Load Area (ftj Load number (Bluh/ftx°F) Bluhlft� or perimeter (ft) (etuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Cool Gross N/P!S Heal Cad 6 %L--(' 12E-0sw 0.068 n 1.90 1.35 301 138 252 186 75 34 65 47 w 4A5-2om 12E-Osw 0.770 0.068 n a 21.56 1.90 19.31 1.35 163 376 0 376 3519 716 3151 509 41 0 0 0 880 0 788 0 w L—D 12E-Osw 0.068 s 1.90 1.35 301 280 533 379 0 0 0 0 11 11DO 0.390 s 10.92 11.31 21 21 229 238 0 0 0 0 w 12E-Osw 0.068 w 1.90 1.35 376 376 716 509 160 160 304 216 C 16X30-Omd 0.408 - 1.18 1.03 1280 1280 1598 1324 136 136 160 141 F 22A-tpl 0.989 - 27.69 0.00 1280 144 39M 0 136 26 692 0 61 c) AED excursion 0 0 Envelope lossigain 11470 6295 2102 1191 12 a) Infiltration 2777 760 482 132 b) Roan ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 3 690 0 0 Applianceslother 1200 0 Subtotal (lines 6 to 13) 14247 8945 2584 1323 Less external lead 0 0 0 O Less transfer O O 0 0 Redistribution 0 0 0 0 14 Subtotal 14247 8945 2584 1323 15 Duct loads 18% 48% 2557 4299 22% 54% 678 709 Trial room load 16805 13244 1 3162 2032 Air required (cfm) 597 597 112 92 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrightsaft- 2016Jul-2008:48:08 h Right-Su8eO Universal 2017 17.0.03 RSUD8101 Page 1 C:1Users%Quick Calcs\Documents%GOTTI RESIDENCE.rup Cale -MJ8 Front Doorfaces: N fl wrightsoftRight-JO Worksheet Job: Entire House Date: Jul 19, zote QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@,AOL.COM 1 Room name WIC 1 BATH 1 2 Exposed wall 11.0 ft 20.0 ft 3 Room height 9.4 ft heaUcool 9.4 ft heall ool 4 Room dimensions 4.0 x 11.0 ft 8.0 x 12.0 It 5 - Room area 44.0 ft2 96.0 ft2 Ty Construction U-value Or HTM Area (ftj Load Area (ft2) Load number (Btut✓ftx°F) (Btuh/ftj or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross N/P/S Heat Ccol Grass N/P/S Heat Cool 8 If12E-Gsw 0.068 n 1.90 1.35 0 0 0 0 0 0 0 0 - 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0 0 0 W 12E-Osw 0,068 a 1.90 1.35 0 0 0 0 0 0 0 0 Vrl �D 12E-0sw 0.068 s 1.90 1.35 0 0 0 0 75 75 143 102 11 11D0 0.390 5 10.92 11.31 0 0 0 0 0 0 0 0 W 12E-0sw 0.068 w 1.90 1.35 103 103 197 140 113 113 215 153 C 16X304)md 0.408 - 1.18 1.03 44 44 52 46 96 96 113 99 F 22A-td 0.989 - 2T69 0.00 44 11 305 0 96 20 554 0 6 0) AED excursion 0 0 Envelope loss/gain 553 185 1025 354 12 a) InfiOmtion 212 58 386 106 b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliancesfother 0 0 Subtotal (liras 6 to 13) 765 244 1411 459 Less external bad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 765 244 1411 459 15 Duct loads 220/. 54% 171 130 0% 00% 0 0 Total room load 937 374 1411 459 Air required (cfm) 33 17 50 21 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. w ig~tsafV Rlght-Sufle® Universal 2017 17.0.03 RSU08101 2016-Ju420 08Page 2 C;1UserslOuick Ce1cs10acumentslGOTTI RESIDENCE.mp Colo = MJB Front Door Laces: N 9 wrightsoftRight-M Worksheet Job: EntireHouse Date: Jul 19, lode QUICK CALCS, INC. 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN GREATROOM 2 Exposed wall 16.0 It 16.0 ft 3 Room height 9.4 ft heai/cool 9.4 It heavicool 4 Room dimensions 16.0 x 12.0 It 16.0 x 28.0 It 5 Room area 192.0 W 448.0 112 Ty Constmdion U-value Or HTM Area (W) Lead Area (ftj lead number (Btuh/ft-F) (Btuh/ftl or perimeter (ft) (Btuh) or pedmeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cod Gross N/P/S Heat Cod 6 %Y12E-0sw 0.068 n 1.90 1.35 0 0 0 0 150 69 131 93 - 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 82 0 1759 1575 W 12E-0sw 0.068 a 1.90 1.35 0 0 0 0 0 0 0 0 1�/ L--D 12E-0sw 0.068 s 1.90 1.35 150 129 246 175 0 0 0 0 11 11D0 0.390 s 10.92 11.31 21 21 229 238 0 0 0 0 W 12E-0sw 0.088 w 1.90 1.35 0 0 0 0 0 0 0 0 C 16X30-0md 0.408 - 1.18 1.03 192 192 226 199 448 44B 528 463 F 22A-tpI 0.989 - 27.69 0.00 192 16 443 0 448 16 443 0 8 c)AED wwrsion 0 0 Envelope loss/gain 1145 611 2861 2132 12 a) Infiltration 309 84 309 84 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 3 690 Appliancesfother 1200 0 Subtotal pines 6 to 13) 1454 1896 3170 2906 Less edema] load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1454 1896 3170 2908 15 Duct loads 22% 54% 325 1015 22% 54% 709 1557 Total room lead 1779 2911 3979 4463 Air required (cfm) 63 131 138 201 Calculations awroved by ACCA to meet all requirements of Manual J 8th Ed -Fk wrightsoft- 2016-Jul-2008:48:08 A Right-Suae® Universal 201717.0.03 RSU08101 Page 3 C:kUsemkQuick Celes\Documents%GOTTIRESIDENCE.mp Calc=MJS Front Doorfaces: N +wrightsoft Right-M)Worksheet Job: Entire House Date: Jul 19, 2016 QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCSP_AOL.COM 1 Room name BEDROOM 2 BATH 2 2 Exposed wall 25.0 ft 20.0 It 3 Room height 9.4 It heat/cool 9.4 ft heat/cool 4 _ Room dimensions. 8.0 x 17.0 ft 8.0 x 120 B 5 Room area 136.0 It' 96.0 ft' Ty Construction U-value Or HTM Area (ftj Lead Area Oil Load number (BluWff'-°F) (BtutVft') a perimeter (ft) (Btuh) or perimeter (ft) (stub) Heal Cool Gross N/P/S Heat Cod Gross N/P/S Heat Cool 6 V,J 12E-Osw 0.068 n 1.90 1.35 75 34 65 47 0 0 0 0 _ 4A5-2om 0.770 n 21.56 19.31 41 0 880 788 0 0 0 0 W 12E-0sw 0.068 a 1.90 1.35 160 160 304 216 113 113 216 153 l�' _ 12E-Osw 0.068 s 1.90 1.35 0 0 0 0 75 75 143 102 11 11D0 0.390 S 10.92 11,31 0 0 0 0 0 0 0 0 W 12E-Osw 0.068 w 1.90 1.35 0 0 0 0 0 0 0 0 C 16X30-0md 0.408 - 1.18 1.03 136 136 160 141 96 96 113 99 F 27A-tp 0.989 - 27.69 0.00 136 25 692 0 98 20 654 0 6 c) AED excursion 101 1 0 Envelope loss/gain 2102 1191 1025 354 12 a) Infiltration 482 132 386 106 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants ® 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 25M 1323 1411 459 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2584 1323 1411 459 15 Duct loads 22% 54% 678 709 00% 0% 0 0 Trial room load 3162 2032 1411 459 Air required (cfm) 112 92 50 21 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. W r•ightsoTt RlghtSuBeO Universal 2017 17.0.03 RSU08101 2016Ju420 OBPage 4 C:1User31Quick CekslDocuments\GOTTI RESIDENCE.mp Cale =MJB Fmnt Door laces: N 9 1 wrightsofC Right-M Worksheet Job: Entire House Date: Jul 19, zols QUICK CALCS, INC. By: 317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name WIC 2 HALL 2 Exposed wall 11.0 It 0 It 3 Room height 9.4 It heal/cool 9.4 It heat/cool 4 Room dimensions 4.0 x 11.0 It 4.0 x 11.0 ft -5 _Room area 44.0 ft2 44.0 ft2 TY Construction U-value Or HTM Area (ft2) Load Ales (ft2) Load number (B1uh/ftk"F) (BtulVft2) or perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross N/P/S Heat Ccol Gross N/P/S Heat Cool 6 LS/ 12E-Osw 0.068 n 1.90 1.35 0 0 0 0 0 0 0 0 _ 4A5-2om 0.770 n 21.56 19.31 0 0 0 0 0 0- 0 0 W 12E-Osw 0.068 a 1.90 1.35 103 103 197 140 0 0 0 0 W 1--D 12E-Osw 0.068 s 1.90 1.35 0 0 0 0 0 0 0 0 11 1ID0 0.390 s 10.92 11.31 0 0 0 0 0 0 0 0 W 12E-Osw 0.088 w 1.90 1.35 0 0 0 0 0 0 0 0 C 16X30-Omd 0.408 = 1.18 1.03 44 44 52 46 44 44 52 46 F 22A-tpI 0.989 - 27.69 0.00 44 11 305 0 44 0 0 0 6 c) AED excursion 0 0 Envelope loss/gain 553 185 52 46 12 a) Infiltration 212 68 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 1 765 244 52 46 Less external load 0 0 O 0 Less transfer 0 0 0 0 Redistribution 0 01 6 0 14 Subtotal 765 2441 52 46 15 Duct loads 22% 54% 171 130 22% 54% 12 24 Total room load 937 374 63 70 Air required (cfm) 33 17 2 3 ,.r .pCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. . A T' wrightsolFt 2016Jup20 O RlghtSukeO Universal 201717.0.03 RSU08101 Page C:\Users\Quick CalcsVI)mumems%GOTTIRESIDENCE.mp Calc=MJB Front Doorlaces: N wrightscifr Right-J® Worksheet Jab: Entire House Date: Jul 19, 2016 QUICK CALCS, INC. By. 317 Sr. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fa�c 772-46r,6796 Email: QUICKCALCSQAOLCOM 1 Room name HALL 2 Exposed wall 0 ft 3 Room height 9.4 ft heat1cool 4 Room dimensions. 4.0 x 11.0 ft 5 Room area 44.0 fl' Ty Construction U-value Or HTM Area (ft� Load Arm Load number (Bluh1ftMF) (Btuh/ftj or perimeter (ft) (Btuh) a perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cod 6 12E-Oaw 0.068 n 1.90 1.35 0 0 0 0 4AS-20M 0.770 n 21.56 19.31 0 0 0 0 w 12E-Osw 0.088 a 1.90 1.35 0 0 0 0 w )--D 12E-Osw 0.068 s 1.90 1.35 0 0 0 0 11 11D0 0.390 s 10.92 11.31 0 0 0 0 w 12E-Osw 0.068 w 1.90 1.35 0 0 0 0 C 16X30-Omd 0.408 - 1.18 1.03 44 44 52 46 F 22A4pl 0.989 - 27.69 0.00 44 0 0 0 6 c) AED excursion 0 Envelope loss/gain 52 46 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants Q 230 0 0 Applianceslother 0 Subtotal (lines 6 to 13) 52 46 Less external load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 52 46 15 Duct loads 22% 54% 12 24 Total room load 63 70 Air required (crm) 21 3 ,4i� Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. '+T+- wrighttsoft' 2016-Jul-2008:48:08 h RlghtSuileO Universe] 2017 17.0.03 RSU08101 Page 6 CAUsers\Quick CalcslDocumentslGOTTI RESIDENCE.rup Cale =MJ8 Front Door faces: N