HomeMy WebLinkAboutENERGY EFFICIENCY CODERECEIV77D JUN 201017
FORM R405-2014
1ro y I
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: GOTTI RESIDENCE
Builder Name:
Street:_ 4600 GRADY DRIVE
SCANNED
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
BY
Permit Number:
Owner: GOTTI
Jurisdiction:
Design Location: FL, Fort Pierce
St. Lucie County
County:: ST. LUCIE COUNTY (Florida Climate Zone 2 )
• 1. New construction or existing
New (From Plans)
9. Wall Types (1364.4 sqft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Frame - Wood, Exterior
R=19.0 1354.40 ft2
b. N/A
R= ft2
3. Number of units, if multiple family
1
c. WA
R= ft'
4. Number of Bedrooms
2
d. WA
R= ft2
5. Is this a worst case?
No
10. Ceiling Types (1280.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 1280.00 ft'
6. Conditioned floor area above grade (ft')
1280
b. N/A
R= ft'
Conditioned floor area below grade
0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(173.0 sqft.) Description
Area
a. U-Factor: Dbl, U=0.65
173.00 ft2
SHGC: SHGC=0.25
b. U-Factor. N/A
ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
9.0 SEER:18.00
b. Central Unit
9.0 SEER:18.00
c. U-Factor: N/A
ft2
2 additional cooling systems
(see details)
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A
ft.
a. Electric Heat Pump
9.0 HSPF:8.50
SHGC:
b. Electric Heat Pump
9.0 HSPF:8.50
Area Weighted Average Overhang Depth:
7.688 ft.
2 additional heating systems
(see details)
Area Weighted Average SHGC:
0.250
14. Hot water systems
a. Propane
Cap: 40 gallons
8. Floor Types (1280.0 sqft.)
Insulation Area
EF: 0.590
a. Raised Floor
R=11.0 1280.00 ft2
b. Conservation features
b. N/A
R= ft2
None
c. N/A
R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.135
Total Proposed Modified Loads: 39.98
PASS
Total Baseline
Loads: 49.25
1 hereby certify that the plans and specifications covered by
Review of the plans and
f2tiE ST9 j
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance
°'F 'j
with the Florida Energy Code.
y�',,,
4ry h5'."
PREPA D Y' M_A_2H"UXWBefore
construction is completed
r
DATE:
this building will be inspected for
compliance with Section 553.908
0 Jry
n
I hereby certify that this buildin as designed, is in compliance
Florida Statutes.
lt,
with the Florida Energy de
Cbb WE
OWNER/AGENI
BUILDING OFFICIAL:
DATE: -
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with ]wand an envelope leakage
test report in accordance with R402.4.1.2. -`(C co
,_
6/23/2017 10:15 AM EnergyGaugeO USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
PROJECT
Title: GOTTI RESIDENCE
Bedrooms: 2
Address Type:
Street Address
Building Type: User
Conditioned Area: 1280
Lot #
Owner. GOTTI
Total Stories: 1
Block/SubDivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
4600 GRADY DRIVE
Permit Office: ST.-LUCIE COUNTY
Cross Ventilations No
County:
ST. LUCIE COUNTY
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
IECC Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location
TMY Site Zone 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 2 39
90
70
75
299
62
Low
BLOCKS
Number Name
Area
Volume
1 UNIT 1
320
3008
2 UNIT2
336
3158.4
3 UNIT3
320
3008
4 UNIT4
304
2812.8
SPACES
Number Name
Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 BEDROOM 1
136
1278.4 No
2
1
1
Yes
Yes
Yes
2 WIC 1
44
413.6 No
0
1
Yes
Yes
Yes
3 BATH 1
96
902.4 No
0
1
Yes
Yes
Yes
4 HALL.
44
413.6 No
0
1
No
Yes
Yes
5 GREAT ROOM
336
3158.4 No
1
1
Yes
Yes
Yes
6 BEDROOM 2
136
1278.4 No
2
1
1
Yes
Yes
Yes
7 BATH 2
96
902.4 No
0
1
Yes
Yes
Yes
8 WIC 2
44
413.6 No
0
1
Yes
Yes
Yes
9 HALL
44
413.6 No
0
1
No
Yes
Yes
10 KITCHEN
192
1804.8 Yes
2
1
Yes
Yes
Yes
11 GREAT
112
1008 No
0
1
No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Raised Floor
BEDROOM 1 __ __
136 ft'
11
0 1
0
2 Raised Floor
WIC 1 _ —
44 ft'
11
0 1
0
3 Raised Floor
BATH 1
96 ft'
11
0 1
0
4 Raised Floor
HALL
44 ft'
11
0 1
0
6/23/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
5 Raised Floor
GREAT ROOM _-
__
336 ft'
11
0
1
0
6 Raised Floor
BEDROOM 2 ___
_-
136 ft2
11
0
1
0
7 Raised. Floor
.BATH 2. _-
96 ft2
11
0
1.
0.
8 Raised Floor
WIC 2 ____
-_
44 ft'
11
0
1
0
9 Raised Floor
HALL ____
___
44 ft2
11
0
1
0
1 ORaised Floor
KITCHEN ____
___
192 ft2
11
0
1
0
11Raised Floor
GREAT __
__
112 ft2
11
0
1
0
ROOF
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed Metal 1422 ft2
224 ft2
Light
0.6
No
0.9
No
20
18.4
ATTIC
/
V
# Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Unvented
0
1349 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Unvented)
BEDROOM 1
20
Blown
136 ft2
0.1
Wood
2 Under Attic (Unvented)
WIC 1
20
Blown
44 ft2
0.1
Wood
3 Under Attic (Unvented)
BATH 1
20
Blown
96 ft2
0.1
Wood
4 Under Attic (Unvented)
HALL.
20
Blown
44 ft2
0.1
Wood
5 Under Attic (Unvented)
GREAT ROOM
20
Blown
336 ft'
0.1
Wood
6 Under Attic (Unvented)
BEDROOM 2
20
Blown
136 ft2
0.1
Wood
7 Under Attic (Unvented)
BATH 2
20
Blown
96 ft'
0.1
Wood
_
8 Under Attic (Unvented)
WIC 2
20
Blown
44 ft'
0.1
Wood
9 Under Attic (Unvented)
HALL
20
Blown
44 ft'
0.1
Wood
10 Under Attic (Unvented)
KITCHEN
20
Blown
192 ft2
0.1
Wood
11 Under Attic (Unvented)
GREAT
20
Blown
112 ft2
0.1
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing
Solar
Below
Space
1
S Exterior Frame - Wood
BEDROOM 1
19 17
0 9
5
160.1 ft2
0
0.25
0.6
0
2
W Exterior Frame - Wood
BEDROOM 1
19 8
0 9
5
75.2 ft2
0
0.25
0.6
0
3
S Exterior Frame - Wood
WIC 1
19 11
0 9
5
103.4 ft2
0
0.25
0.6
0
4
E Exterior Frame - Wood
BATH 1
19 8
0 9
5
75.2 ft2
0
0.25
0.6
0
5
S Exterior Frame - Wood
BATH 1
19 12
0 9
5
112.8 ft2
0
0.25
0.6
0
6/23/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Belo w
Space
1.
6
W
Exterior Frame - Wood
GREAT ROO 19 16 0 9
5 150.4 ft2
0
0.25
0.6
0
7
N
Exterior Frame - Wood
BEDROOM 2 19 17 0 9
5 160.1 ft2
0
0.25
0.6
0
8
W
Exterior Frame - Wood
BEDROOM 2 19 8 0 9
5 75.2 ft2
0
0.25
0.6
0
9
N
Exterior Frame - Wood
BATH 2 19 12 0 9
5 112.8 ft2
0
0.25
0.6
0
10
E
Exterior Frame - Wood
BATH 2 19 8 0 9
5 75.2 ft2
0
0.25
0.6
0
11
N
Exterior Frame - Wood
WIC 2 19 11 0 9
5 103.4 ft2
0
0.25
0.6
0
12
E
Exterior Frame - Wood
KITCHEN 19 16 0 9
5 150.7 ft2
0
0.25
0.6
0
DOORS
#
Ornt Door Type
Space Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
E Insulated
KITCHEN None
.39 3
7
21 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
V
#
Ornt ID Frame Panes
NFRC U-Factor SHGC
Area Depth
Separation
Int Shade
Screening
1
W 2 Metal Low-E Double
Yes 0.65 0.25
41.0 ft2 8 ft 0 in
1 ft 4 in
None
None
2
W 6 Metal Low-E Double
Yes 0.65 0.25
82.0 ft2 8 ft 0 in
1 ft 4 in
None
None
3
W 8 Metal Low-E Double
Yes 0.65 0.25
41.0 ft2 8 ft 0 in
1 ft 4 in
None
None
4
E 12 Metal Low-E Double
Yes 0.65 0.25
9.0 ft2 2 ft 0 in
1 ft 4 in
None
None
INFILTRATION
#
Scope
Method
SLA CFM 50 ELA EgLA ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000417
1398.5 76.78 144.39 .3041
7
HEATING SYSTEM
#
System Type
Subtype Efficiency
Capacity
Block
Duds
1
Electric Heat Pump
Split HSPF:8.5
9 kBtulhr
1
Ductless
2
Electric Heat Pump
Split HSPF:8.5
9 kBtulhr
2
Ductless
3
Electric Heat Pump
Split HSPF:8.5
9 kBtulhr
3
Ductless
4
Electric Heat Pump
None HSPF:8.5
9 kBtu/hr
4
Ductless
COOLING SYSTEM
#
System Type
Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit
Split SEER: 18
9 kBtu/hr
cfm
0.7 1
Ductless
2
Central Unit
Split SEER: 18
9 kBtu/hr
cfm
0.7 2
Ductless
3
Central Unit
Split SEER: 18
9 kBtu/hr
cfm
0.7 3
Ductless
4
Central Unit
None SEER: 18
9 kBtu/hr 270 cfm
0.7 4
Ductless
6/23/2017 10:15 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Propane
None
KITCHEN
0.59
40 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
.Storage
Carl #
Company Name
System Model #
Collector Model #
Area
Volume
FEF
None
None
ft'
TEMPERATURES
Programabl[e
Ceiling Fans:
an
Heat ng pq Jan
[X] Feb
Mar
Mar
Apr
May 11
[X]
Jun [
]Jul
X�
4 ]Aug
[X]
[ ]Sep
[ ][XOct]]
L J
Oct
Nov
[rX'�
Venting [ I Jan
[) Feb
X Mar
Jun [)
Jul
[) Aug
[ )
Sep lxl
[X]
[ ]Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
6/23/2017 10:16 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: GOTTI RESIDENCE Builder Name:
Street: 4600 GRADY DRIVE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: GOTTI Jurisdiction:
Design Location: FL, Fort Pierce
COMPONENT
CRITERIA
CHECK
Air barrier and thermal barrier
A continuous air barrier shall be installed in the building envelope.
Exterior thermal envelope contains a continuous barrier.
Breaks orjoints in the air barrier shall be sealed.
Air -permeable insulation shall not be used as a sealing material.
Ceiling/aftic
The air barrier in any dropped ceiling/soffit shall be aligned with the
insulation and any gaps in the air barrier shall be sealed.
Access openings, drop down stairs or knee wall doors to unconditioned
attic spaces shall be sealed.
Corners and headers shall be insulated and the junction of the foundation
Walls
and sill plate shall be sealed.
The junction of the top plate and the top or exterior walls shall be sealed.
Exterior thermal envelope insulation for framed walls shall be installed in
substantial contact and continuous alignment with the air barrier.
Knee walls shall be sealed.
Windows, skylights and doors
The space between window/doorjambs and framing and skylights and
framing shall be sealed.
Rim joists
Rim joists are insulated and include an air barrier.
Floors (including above -garage
Insulation shall be installed to maintain permanent contact with underside
and cantilevered floors)
of subfloor decking.
The air barrier shall be installed at any exposed edge of insulation.
Crawl space walls
Where provided in lieu of floor insulation, insulation shall be permanently
attached to the crawlspace walls.
Exposed earth in unvented crawl spaces shall be covered with a Class I
vapor retarder with overlapping joints taped.
Shafts, penetrations
Duct shafts, utility penetrations, and flue shaft openings to exterior or
unconditioned space shall be sealed.
Narrow cavities
Batts in narrow cavities shall be cut to fit, or narrow cavities shall be filled
by insulation that on installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope shall be
airtight, IC rated, and sealed to the drywall.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring and plumbing in
exterior walls, or insulation that on installation readily conforms to available
space shall extend behind piping and wiring.
Shower/tub on exterior wall
Exterior walls adjacent to showers and tubs shall be insulated and the air
barrier installed separating them from the showers and tubs.
Electrical/phone box on
The air barrier shall be installed behind electrical or communication boxes or
air sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall be
sealed to the sub -floor or drywall.
Fireplace
An air barrier shall be installed on fireplace walls. Fireplaces shall have
gasketed doors
6/23/2017 10:16 AM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 1
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 81
The lower the EnergyPerformance Index, the more efficient the home.
4600 GRADY DRIVE, FT. PIERCE, FL,
' 1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft'
7. Windows"
Description
a. U-Factor:
Dbl, U=0.65
SHGC:
SHGC=0.25
b. U-Factor:
N/A
SHGC:
c. U-Factor:
N/A
SHGC:
d. U-Factor.
N/A
SHGC:
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Raised Floor
b. N/A
c. N/A
New (From Plans)
Single-family
1
2
No
1280
Area
173.00 ft'
ft'
ftz
ft'
7.688 ft.
0.250
Insulation
Area
R=11.0
1280.00 ft'
R=
ft'
R=
ft'
9. Wall Types
a. Frame - Wood, Exterior
b. N/A
c. N/A
d. N/A
10. Ceiling Types
a. Roof Deck (Unvented)
b. N/A
c. N/A
11. Ducts
12. Cooling systems
a. Central Unit
b. Central Unit
2 additional cooling systems
13. Heating systems
a. Electric Heat Pump
b. Electric Heat Pump
2 additional heating systems
14. Hot water systems
a. Propane
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code commgiant features.
Builder Signature: ly_- Date: Ds..c-;tS zo/ 17
Address of New Home: 140)MDA 1 1,42 City/FL
Ltl�/J
Insulation
R=19.0
R=
R=
R=
Insulation
R=20.0
R=
R=
Area
1354.40 ft'
ft'
ft'
ft'
Area
1280.00 fP
ft'
ft'
R ft'
kBtu/hr
Efficiency
9.0
SEER:18.00
9.0
SEER:18.00
(see details)
kBtu/hr
Efficiency
9.0
HSPF:8.50
9.0
HSPF:8.50
(see details)
Cap: 40 gallons
EF: 0.59
Pstat
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support
staff.
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
6/23/2017 10:15 AM EnergyGauge® USA - FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
Project Job:
t S
-F wrightsoft° i SCANNED By:
Ju119,2015
Entire House BY r
QUICK CALCS, INC. St. Lucie Count
Phone:
317 ST. LUCIE LN., FT. PIERCE, FL 34946 772-466-6799 Fax 772-4GSG796 Email: QUICKCALCS� L.COM
Project Information
For: GOTTI RESIDENCE
.00 GRADY DRIVE,• s t ! C41%0%
Design Information
Weather: Fort Pierce, FL, US
Winter Design Conditions
Outside db
42
OF
Inside db
70
OF
Design TD
28
OF
Heating Summary
Structure
14247
Btuh
Ducts
2557
Btuh
Central vent (24 cfm)
741
Btuh
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
17545
Btuh
Infiltration
Method Simplified
Construction quality Average
Fireplaces 0
Heatingg
Coolingg
Area (ft2)
1280
1280
Volume (ft3)
12032
12032
Air changes/hour
0.45
0.23
Equiv. AVF (cfm)
90
46
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
5.1
kW
17448
Btuh
27
OF
597
cfm
0.036
cfm/Btuh
0
in H2O
Summer Design Conditions
Outside db
90
OF
Inside db
75
OF
Design TO
15
OF
Daily range
L
Relative humidity
50
%
Moisture difference
61
gr/lb
Sensible Cooling Equipment Load Sizing
Structure 8945 Btuh
Ducts 4299 Btuh
Central vent (24 cfm) 397 Btuh
Blower 0 Btuh
Use manufacturer's data n
Ratelswing multiplier 0.95
Equipment sensible load 12959 Btuh
Latent Cooling Equipment Load Sizing
Structure
2527
Btuh
Ducts
1293
Btuh
Central vent (24 cfm)
1005
Btuh
Equipment latent load
4825
Btuh
Equipment total load
17784
Btuh
Req. total capacity at 0.70 SHR
1.5
ton
Cooling Equipment Summary
Make Trane
Trade TRANE
Cond 4TTR6018B1
Coil TEM6AOB24H21++TDR
AHRI ref 7567552
Efficiency 13.0 EER, 16 SEER
Sensible cooling
Latent cooling
Total cooling
Actual air flow
Air flow factor
Static pressure
Load sensible heat ratio
12530 Btuh
5370 Btuh
17900 Btuh
�597 cfm
�(),045 cfm/Btuh
LL�lC00 , 0 in H2O
�®
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
wri hf Soft 2016-Jul-2008:48:08
9 Right-SuReO universal 201717.0.03 RSU08101 Page 1
ACM C: UserslQuick CaIcskDocuments1GOT1-1 RESIDENCE.mp Cale = MA From Door faces: N
F wrightsoft Right-M Worksheet Job:
Entire House Date: Jul 19, 2016
8y:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-4666799 Fax 772-466-6796 Email: QUICKCALCS AOL.COM
1
Room name
Entire House
BEDROOM 1
2
Exposed wall
144.0 ft
25.0 ft
3
Room height
9.4 ft d
9.4 ft heat/cool
4
Room dimensions
8.0 x 17.0 ft
5
- Room area
1280.0 ft'
136.0 fN
Ty
Construction
U-value
Or
HTM
Area (ftj
Load
Area (ftj
Load
number
(Bluh/ftx°F)
Bluhlft�
or perimeter (ft)
(etuh)
or perimeter (ft)
(Btuh)
Heat
Cool
Gross
N/PIS
Heat
Cool
Gross
N/P!S
Heal
Cad
6
%L--('
12E-0sw
0.068
n
1.90
1.35
301
138
252
186
75
34
65
47
w
4A5-2om
12E-Osw
0.770
0.068
n
a
21.56
1.90
19.31
1.35
163
376
0
376
3519
716
3151
509
41
0
0
0
880
0
788
0
w
L—D
12E-Osw
0.068
s
1.90
1.35
301
280
533
379
0
0
0
0
11
11DO
0.390
s
10.92
11.31
21
21
229
238
0
0
0
0
w
12E-Osw
0.068
w
1.90
1.35
376
376
716
509
160
160
304
216
C
16X30-Omd
0.408
-
1.18
1.03
1280
1280
1598
1324
136
136
160
141
F
22A-tpl
0.989
-
27.69
0.00
1280
144
39M
0
136
26
692
0
61
c) AED excursion
0
0
Envelope lossigain
11470
6295
2102
1191
12
a) Infiltration
2777
760
482
132
b) Roan ventilation
0
0
0
0
13
Internal gains: Occupants Q 230
3
690
0
0
Applianceslother
1200
0
Subtotal (lines 6 to 13)
14247
8945
2584
1323
Less external lead
0
0
0
O
Less transfer
O
O
0
0
Redistribution
0
0
0
0
14
Subtotal
14247
8945
2584
1323
15
Duct loads
18%
48%
2557
4299
22%
54%
678
709
Trial room load
16805
13244
1
3162
2032
Air required (cfm)
597
597
112
92
Calculations approved byACCA to meet all requirements of Manual J 8th Ed.
wrightsaft- 2016Jul-2008:48:08
h Right-Su8eO Universal 2017 17.0.03 RSUD8101 Page 1
C:1Users%Quick Calcs\Documents%GOTTI RESIDENCE.rup Cale -MJ8 Front Doorfaces: N
fl wrightsoftRight-JO Worksheet Job:
Entire House Date: Jul 19, zote
QUICK CALCS, INC. By:
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@,AOL.COM
1
Room name
WIC 1
BATH 1
2
Exposed wall
11.0 ft
20.0 ft
3
Room height
9.4 ft heaUcool
9.4 ft heall ool
4
Room dimensions
4.0 x 11.0 ft
8.0 x 12.0 It
5
- Room area
44.0 ft2
96.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ftj
Load
Area (ft2)
Load
number
(Btut✓ftx°F)
(Btuh/ftj
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Bluh)
Heat
Cool
Gross
N/P/S
Heat
Ccol
Grass
N/P/S
Heat
Cool
8
If12E-Gsw
0.068
n
1.90
1.35
0
0
0
0
0
0
0
0
-
4A5-2om
0.770
n
21.56
19.31
0
0
0
0
0
0
0
0
W
12E-Osw
0,068
a
1.90
1.35
0
0
0
0
0
0
0
0
Vrl
�D
12E-0sw
0.068
s
1.90
1.35
0
0
0
0
75
75
143
102
11
11D0
0.390
5
10.92
11.31
0
0
0
0
0
0
0
0
W
12E-0sw
0.068
w
1.90
1.35
103
103
197
140
113
113
215
153
C
16X304)md
0.408
-
1.18
1.03
44
44
52
46
96
96
113
99
F
22A-td
0.989
-
2T69
0.00
44
11
305
0
96
20
554
0
6
0) AED excursion
0
0
Envelope loss/gain
553
185
1025
354
12
a) InfiOmtion
212
58
386
106
b) Room ventilation
0
0
0
0
13
Intemal gains: Occupants @ 230
0
0
0
0
Appliancesfother
0
0
Subtotal (liras 6 to 13)
765
244
1411
459
Less external bad
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
765
244
1411
459
15
Duct loads
220/.
54%
171
130
0%
00%
0
0
Total room load
937
374
1411
459
Air required (cfm)
33
17
50
21
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
w ig~tsafV Rlght-Sufle® Universal 2017 17.0.03 RSU08101 2016-Ju420 08Page 2
C;1UserslOuick Ce1cs10acumentslGOTTI RESIDENCE.mp Colo = MJB Front Door Laces: N
9
wrightsoftRight-M Worksheet Job:
EntireHouse Date: Jul 19, lode
QUICK CALCS, INC.
317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
KITCHEN
GREATROOM
2
Exposed wall
16.0 It
16.0 ft
3
Room height
9.4 ft heai/cool
9.4 It heavicool
4
Room dimensions
16.0 x 12.0 It
16.0 x 28.0 It
5
Room area
192.0 W
448.0 112
Ty
Constmdion
U-value
Or
HTM
Area (W)
Lead
Area (ftj
lead
number
(Btuh/ft-F)
(Btuh/ftl
or perimeter (ft)
(Btuh)
or pedmeter (ft)
(Btuh)
Heat
Cod
Gross
N/P/S
Heat
Cod
Gross
N/P/S
Heat
Cod
6
%Y12E-0sw
0.068
n
1.90
1.35
0
0
0
0
150
69
131
93
-
4A5-2om
0.770
n
21.56
19.31
0
0
0
0
82
0
1759
1575
W
12E-0sw
0.068
a
1.90
1.35
0
0
0
0
0
0
0
0
1�/
L--D
12E-0sw
0.068
s
1.90
1.35
150
129
246
175
0
0
0
0
11
11D0
0.390
s
10.92
11.31
21
21
229
238
0
0
0
0
W
12E-0sw
0.088
w
1.90
1.35
0
0
0
0
0
0
0
0
C
16X30-0md
0.408
-
1.18
1.03
192
192
226
199
448
44B
528
463
F
22A-tpI
0.989
-
27.69
0.00
192
16
443
0
448
16
443
0
8
c)AED wwrsion
0
0
Envelope loss/gain
1145
611
2861
2132
12
a) Infiltration
309
84
309
84
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants@ 230
0
0
3
690
Appliancesfother
1200
0
Subtotal pines 6 to 13)
1454
1896
3170
2906
Less edema] load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
1454
1896
3170
2908
15
Duct loads
22%
54%
325
1015
22%
54%
709
1557
Total room lead
1779
2911
3979
4463
Air required (cfm)
63
131
138
201
Calculations awroved by ACCA to meet all requirements of Manual J 8th Ed
-Fk wrightsoft- 2016-Jul-2008:48:08
A Right-Suae® Universal 201717.0.03 RSU08101 Page 3
C:kUsemkQuick Celes\Documents%GOTTIRESIDENCE.mp Calc=MJS Front Doorfaces: N
+wrightsoft Right-M)Worksheet Job:
Entire House Date: Jul 19, 2016
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCSP_AOL.COM
1
Room name
BEDROOM 2
BATH 2
2
Exposed wall
25.0 ft
20.0 It
3
Room height
9.4 It heat/cool
9.4 ft heat/cool
4
_ Room dimensions.
8.0 x 17.0 ft
8.0 x 120 B
5
Room area
136.0 It'
96.0 ft'
Ty
Construction
U-value
Or
HTM
Area (ftj
Lead
Area Oil
Load
number
(BluWff'-°F)
(BtutVft')
a perimeter (ft)
(Btuh)
or perimeter (ft)
(stub)
Heal
Cool
Gross
N/P/S
Heat
Cod
Gross
N/P/S
Heat
Cool
6
V,J
12E-Osw
0.068
n
1.90
1.35
75
34
65
47
0
0
0
0
_
4A5-2om
0.770
n
21.56
19.31
41
0
880
788
0
0
0
0
W
12E-0sw
0.068
a
1.90
1.35
160
160
304
216
113
113
216
153
l�'
_
12E-Osw
0.068
s
1.90
1.35
0
0
0
0
75
75
143
102
11
11D0
0.390
S
10.92
11,31
0
0
0
0
0
0
0
0
W
12E-Osw
0.068
w
1.90
1.35
0
0
0
0
0
0
0
0
C
16X30-0md
0.408
-
1.18
1.03
136
136
160
141
96
96
113
99
F
27A-tp
0.989
-
27.69
0.00
136
25
692
0
98
20
654
0
6
c) AED excursion
101
1
0
Envelope loss/gain
2102
1191
1025
354
12
a) Infiltration
482
132
386
106
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants ® 230
0
0
0
0
Appliances/other
0
0
Subtotal (lines 6 to 13)
25M
1323
1411
459
Less external load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
2584
1323
1411
459
15
Duct loads
22%
54%
678
709
00%
0%
0
0
Trial room load
3162
2032
1411
459
Air required (cfm)
112
92
50
21
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
W r•ightsoTt RlghtSuBeO Universal 2017 17.0.03 RSU08101 2016Ju420 OBPage 4
C:1User31Quick CekslDocuments\GOTTI RESIDENCE.mp Cale =MJB Fmnt Door laces: N
9
1 wrightsofC Right-M Worksheet Job:
Entire House Date: Jul 19, zols
QUICK CALCS, INC. By:
317 ST. LUCIE UN., FT. PIERCE, FL 34946 Phone: 772466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM
1
Room name
WIC 2
HALL
2
Exposed wall
11.0 It
0 It
3
Room height
9.4 It heal/cool
9.4 It heat/cool
4
Room dimensions
4.0 x 11.0 It
4.0 x 11.0 ft
-5
_Room area
44.0 ft2
44.0 ft2
TY
Construction
U-value
Or
HTM
Area (ft2)
Load
Ales (ft2)
Load
number
(B1uh/ftk"F)
(BtulVft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Bluh)
Heat
Cool
Gross
N/P/S
Heat
Ccol
Gross
N/P/S
Heat
Cool
6
LS/
12E-Osw
0.068
n
1.90
1.35
0
0
0
0
0
0
0
0
_
4A5-2om
0.770
n
21.56
19.31
0
0
0
0
0
0-
0
0
W
12E-Osw
0.068
a
1.90
1.35
103
103
197
140
0
0
0
0
W
1--D
12E-Osw
0.068
s
1.90
1.35
0
0
0
0
0
0
0
0
11
1ID0
0.390
s
10.92
11.31
0
0
0
0
0
0
0
0
W
12E-Osw
0.088
w
1.90
1.35
0
0
0
0
0
0
0
0
C
16X30-Omd
0.408
=
1.18
1.03
44
44
52
46
44
44
52
46
F
22A-tpI
0.989
-
27.69
0.00
44
11
305
0
44
0
0
0
6
c) AED excursion
0
0
Envelope loss/gain
553
185
52
46
12
a) Infiltration
212
68
0
0
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Applianceslother
0
0
Subtotal (lines 6 to 13)
1
765
244
52
46
Less external load
0
0
O
0
Less transfer
0
0
0
0
Redistribution
0
01
6
0
14
Subtotal
765
2441
52
46
15
Duct loads
22%
54%
171
130
22%
54%
12
24
Total room load
937
374
63
70
Air required (cfm)
33
17
2
3
,.r .pCalculations approved by ACCA to meet all requirements of Manual J 8th Ed.
. A T' wrightsolFt 2016Jup20 O RlghtSukeO Universal 201717.0.03 RSU08101 Page
C:\Users\Quick CalcsVI)mumems%GOTTIRESIDENCE.mp Calc=MJB Front Doorlaces: N
wrightscifr Right-J® Worksheet Jab:
Entire House Date: Jul 19, 2016
QUICK CALCS, INC. By.
317 Sr. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fa�c 772-46r,6796 Email: QUICKCALCSQAOLCOM
1
Room name
HALL
2
Exposed wall
0 ft
3
Room height
9.4 ft heat1cool
4
Room dimensions.
4.0 x 11.0 ft
5
Room area
44.0 fl'
Ty
Construction
U-value
Or
HTM
Area (ft�
Load
Arm
Load
number
(Bluh1ftMF)
(Btuh/ftj
or perimeter (ft)
(Btuh)
a perimeter
Heat
Cool
Gross
N/P/S
Heat
Cool
Gross
N/P/S
Heat
Cod
6
12E-Oaw
0.068
n
1.90
1.35
0
0
0
0
4AS-20M
0.770
n
21.56
19.31
0
0
0
0
w
12E-Osw
0.088
a
1.90
1.35
0
0
0
0
w
)--D
12E-Osw
0.068
s
1.90
1.35
0
0
0
0
11
11D0
0.390
s
10.92
11.31
0
0
0
0
w
12E-Osw
0.068
w
1.90
1.35
0
0
0
0
C
16X30-Omd
0.408
-
1.18
1.03
44
44
52
46
F
22A4pl
0.989
-
27.69
0.00
44
0
0
0
6
c) AED excursion
0
Envelope loss/gain
52
46
12
a) Infiltration
0
0
b) Room ventilation
0
0
13
Internal gains: Occupants Q 230
0
0
Applianceslother
0
Subtotal (lines 6 to 13)
52
46
Less external load
0
0
Less transfer
0
0
Redistribution
0
0
14
Subtotal
52
46
15
Duct loads
22%
54%
12
24
Total room load
63
70
Air required (crm)
21
3
,4i� Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
'+T+- wrighttsoft' 2016-Jul-2008:48:08
h RlghtSuileO Universe] 2017 17.0.03 RSU08101 Page 6
CAUsers\Quick CalcslDocumentslGOTTI RESIDENCE.rup Cale =MJ8 Front Door faces: N