HomeMy WebLinkAboutWINDSTORM FRAME INSTALLATION INSTRUCTIONSWindstorm`F,rame Installation Instructions
4do au C Ft9`rUse With FL4553
A.Y 6.1�
F0260 RI
aRgW1 4' In S ERuuE HUa
W W
3070 3 100 PSF MAX. DESIGN LOAD
4080 d: 70 PSF MAX. DESIGN LOAD
4" MIN./14" MAX. DEPTH
16 GA. MIN.
KD OR WELDED (12 GA. WELDED)
IMPACT RATING = 350 FT-LBF
SCANNED
BY
r Luder.nonlhf
II II
II II
II II -
II II!
II II \
II II OPTIONAL
II II HARDWARE
OR HM
II II MULLION _
II II '
H II DOUBLE SWING
II II
II II
II II
II II -
II II
II II
uy
8080 MAX.
4" MIN./14' MAX. DEPTH
16 GA. MIN.
KID OR WELDED (12 GA WELDED)
DESIGN LOAD = +/-70 PSF
IMPACT RATING = 350 F-LBF
ANCHORS & METHOD OF ATTACHMENT
ANCHOR TYPE
'LOCATION
EO - PIPE & SLEEVE
'(BUTTERFLY UP TO 3070 MAX.)
12" MAX, FROM EACH
WOOD BUCK
END & 19" O.C.
3/8' X 6' LAG SCREW
EO - PIPE & SLEEVE
(BUTTERFLY UP TO 3070 MAX.)
12' MAX. FROM EACH
MASONRY BUCK
END & 19" O.C.
3/8- X 6' EXPANSION SHELL
MASONRY i' - GROUTED
16" - 24" O.C.
(Head: 3/8" x 6' Expansion Shell)
® GROUT JOINTS
WIRE MASONRY - .GROUTED
16" - 24' O.C.
(Head: 3/8" x 6" Expansion Shell)
® GROUT JOINTS
WOOD STUD
6", 6" & EOUAL - 21' MAX.
METAL STUD
FOR INTERMEDIATE SPACES
(NO FLOOR ANCHORS)
Poured In Place Wall
NA
'FOR DOUBLE 6 NG FRAMES KITH a FACE FRAME HEADS. (2) EO ANCHORS REQUIRED
WHEN INSTALLED IN MASONRY WALL OR (2) STUD ANCHORS REWIRED MEN INSTALLED
IN STUD WALL LOCATION OF ANCHORS 10 BE 16' FROM CENTERLINE OF FRAME HEAD,
OR CAN BE GROUTED FULL WITH 2O00 P9 MIN. CONCRETE
"FOR SIZES 6070 OR LESS REFER TO TABLE ABOVE.
THREE -SIDED FRAMES
CCecoDoor
MSSMAB"
Trio & Trio-E Opening
--Sizes Over 6070 Pairs
LOCATION
0 Jamb:12"Max. From
Each End & 19" O.C.
® Head: (4) Total Req'd,
9" Max. From Centerline of
Head, 9" Max. from Each Hinge Jamb
® Jamb:12"Max. From
Each End & 19' O.C.
® Head: (4) Total Req'd,
9" Max. From Centerline of
Head, 9" Max. from Each Hinge Jamb
® Jamb:16"-24" O.C.® Grout Joints
® Head: (4) Total Req'd, 9" Max. from
Centerline of Head, 9' Max. From
Each Hinge Jamb.
® Jamb:16'-24" O.C.® Grout Joints
® Heod: (4) Total Req'd, 9" Max. from
Centerline of Head, 9" Max. From
Each Hinge Jamb.
® Jamb:6", 6" & Equal-21" Max
for Intermediate Spaces.
® Head: (4) Total Req'd,
6" Max. From Centerline of Head,
6" Max from Each Hinge Jamb
NA
y�
Page 1 of 15
Fdan a.
D4W1ED HDI.ES:
am FACE'
Windstorm Frame Installation Instructions
t For else With FL 4553
r
.I'- L I L
I� 2.
Lvenia' »I ves es
HINGE JAMBPROFILE
�.��.s
x'
YAR�ES
FRAME. HEAD & LOCK JAMB PROFILE
3070 MAY.
IIN./14 MAY'. DEPTH.
lb -.GA. -WELDED ONLY ". .
DESIGN LOAD = +%-6D PSF (ATHOUT' DEADBOLT)
DESIGN LOAD +'/,-70'" PSF. (WITH, DEADSOLT)
IMPAGT RATING = 350 FT=LBF
OF
PLUMB: ANCHOR
WOOD STUD SCREW
OR
METAL STUD SCREW
TOP ,PLLJMB':ANCHOR
6 STD LOCATION &
BTM .PLUMB ANCHOR
V. 18" MAX: FROM
BTM OF FRAME
TWO-PIECE THREE -SIDED FRAME
CC=Door
ASSAAMDY
Page 2 of 15
Windstorm Frame Installation Instructions
For Use With FL 4553
F0291
KID OR WELDED (12 GA WELDED)
DESIGN LOAD =+F150 PSF
IMPACT RATING =350 Fr-LBF 4"
Aaron"
h.)
100" —
96" Max. Opening
Head Andior (Bolts Only) Locations
83 Anchors Equally Spr d(wen"te"
96 " Max.
Opening
I
i
I
i
it
B--j D
.625" Max Intertior View Pair
ax.
6" Max.}
M
? O
r_
=r 3
o Cr
M
o
1< r
v
r013 0
y
i
6" Max.
M MEMATMAL
14 CAGE(.06/ MIN.) COLD ROILED
OR GALVANIM (A60) STEEL
4• MIN FRAME DEM.
2" Min.
4" Max.
Notes:
1) 8080 max for pairs, 4080 max for singles. Single openings
am described in active leaf ofpair.
2) EO anchor locations shown. MT or WMjamb anchors
are optional. EO bolts only option for header.
3) (2) EO bolts in header up through 3V singles. (3) bolts up thmugh CO" singles.
(4) bolls up through 6V pairs and (5) bolls up through 8V pairs.
4) Hinge (4.5 x 4.5 x .180) locations are Deco standard. Curries &
Fleming locations are optional or+/_ 1" of any locations tested.
5) Frame header is reinforced for 12 gauge lintel.
6) Frame is prepared for approved Multi -point lack and surface bolts
for pairs and approved Multi -point lock forsingles.
7) Frame header is prepared for surface boltstdke. Preparation is in doorrabbet
for inswing as shown and preparation is in soffit for outswing.
THREE -SIDED FRAME
C=—C=Door
AWAAB"
Page 3 of 15
Windstorm Frame Installation Instructions
F0260_A
For.Use With FL 4553
'OPTIONAL F' FACE
F E HEAD
3070 MAX.
4" MIN./14" MAX. DEPTH
16 GA. MIN.
KD OR WELDED (12 GA. WELDED)
DESIGN LOAD = +/-100 PSF
IMPACT RATING = 350 FT-LBF
me vnuac
'ANCHORS & METHOD OF ATTACHMENT
ANCHOR TYPE
'LOCATION
EO - PIPE & SLEEVE
(BUTTERFLY UP TO 3070 MAX.)
12" MAX. FROM EACH
WOOD BUCK
END & 19" O.C.
3/8" X 6" LAG SCREW
EC, - PIPE & SLEEVE
(BUTTERFLY UP TO 3070 MAX.)
12" MAX. FROM EACH
MASONRY BUCK
END & 19" O.C.
3/8" X 6" EXPANSION SHELL
MASONRY "T" - GROUTED
16" - 24" O.C.
GROUT JOINTS
WIRE MASONRY - GROUTED
16" - 24" O.C.
@� GROUT JOINTS
WOOD STUD
6". 6" & EQUAL - 21" MAX.
METAL STUD
(NO FLOOR ANCHORS)
FOR INTERMEDIATE SPACES
Poured In Place Wall
NA
THREE SIDED FRAMES
C Ceco Door
Page 4 of 15
Windstorm Frame Installation Instructions
' For Use With FL 4553
1. DESIGN PRESSURE _ +/- 60 PSF
IMPACT RATING = 350 FT-LBF
2. ALL FRAME PERIMETERS & HEADS OF
FASTENERS SEALED WITH SILICONE.
3. CORNER CONSTRUCTION = WELDED ONLY
4. ANCHORS - SEE CHART BELOW
5. FRAME OEM = 4" MIN. / 14" MAX.
16 CA MIN.
6. DOOR OPENING - S-O" X 8'-0' SINGLE MAX.
6'-0" X B'-O' PAIRS MAX.
7. STOP HEIGHT - 5/8' MIN.
B. FULL HEIGHT VERTICAL & 6' HORIZONTAL
MULLIONS MUST BE REINFORCED WITH
(2) 10-GAUGE X 3/4' X FRAME DEPTH
"C' CHANNELS INSTALLED BACK TO
BACK TO FORM SIMULATED 'F BEAM.
SEE DETAIL 'A -A'.
LA&Y
GLAZING
MATERIAL
DIM.
"B"
DIM.
'C'
DIM.
'D'
DIM.
'E"
FRAME FACES
DIM.
A
MAX.
MAX.
MAX.
MAX.
MIN.
MAX.
GLASS AM
SAFE Y
PLMINAUS 2
36-
72"
36-
94"
2'
4'
LA TED
GLASS
'BEDDING 6 CLOSEO,CELL TOW/ THE 1/B' X 1/2' AND DOW CORNING 995 STRUCTURAL
SIDCONE. 1 3/4' STEEL SIFFENED. HONEYCOMB. POVIUREDWNE, MINERAL CORE OR
POLYSTYRENE CORE PANELS (18 GP HIn - 14 GP MPX) MAY BE USED IN UEU OF
GIASSLAJ, PANELS ARE WELDED TO FRAME WDX WELDS LOCATED ON THE SIDES 3' LVJI.
FROM EACH END & 3' MAX. O.C. & ON THE TOP & BOTTOM 3' MAX. FROM EACH ENO &
AT 12' MAL O.C. THE WELDS ARE MIN. 1/4- WELDS X 1/2' LONG. PANELS TO BE
NSALLED IN EXTERIOR (OUTSIDE) RABBET. WELDS ARE LOCATED WHERE PANEL ABUTS
{RYES MG TI .."o MF SFMFO. III..,
ANCHORS & METHW
OF ATTACHMENT
ANCHOR TYPE
LOCATION
EO - PIPE & SLEEVE
OR BUTTERFLYO
WOOD BUCKK
3/e' % 6' LAG SCREW
O JAMB
12' MAX. FROM SILL, B' FROM HEAD & 20' O.C.
HEAD
••2' FROM EACH VERTICAL MEMBER & 14" O.C.
O SILL
2' FROM EACH VERTICAL MEMBER & O MIDSPAN
. EO - PIPE & SLEEVE
OR BUTTERFLYBUCK MASONRY BUCK
/8" X 6' EXPANSION SHELLE
O JAMB
12' MAX. FROM SILL, S' FROM HEAD & 20' O.C.
O HEAD
"2'{ROM EACH VERTICAL MEMBER & 14' O.C.
O SILL
2' FROM EACH VERTICAL MEMBER & O MIDSPAN
WIRE MASONRY OR
MASONRY T - GROUTED,
WELDED TO STEEL HEADER,
DO P&S OR BUTTERFLY -
3 8' X 6' BOLTS
O JAMB
O HEAD
8' MAX. FROM EACH END & 16" O.C.
"'WELDED TO STEEL CHANNEL HEADER
O SILL
2' FROM EACH VERTICAL MEMBER & O MIDSPAN
WELDED TO STEEL BUCK
O JAMB
—5' MAX. FROM SILL & 27.5' MAX. O.C.
O HEAD
'"WELDED TO STEEL CHANNEL HEADER
O S&L
2' FROM EACH VERTICAL MEMBER & O MIDSPAN
WOOD STUD
METAL STUD
(NO FLOOR ANCHORS)
O JWMB
5' MAX. FROM SILL & 27.5' MAX. O.C.
O HEAD
-2' MAC. FROM EACH VERTICAL MEMBER & 14' O.0
O SILL
2' FROM EACH VERTICAL MEMBER & O MIDSPAN
"FOR V & UP READ MEMBERS FOR HEIRS TES GM W. LOCATE ANCHORS 2' MAX. MOM EACH VERRGL
MEMBER & O UOPgM OF SPNL'
`•'1/4- THICK UM. SHW PLATES (2' WIDE X Y LONG OR TO SUR JNIB DEPTH) WELDED TO MV.
CHANNEL & FRAMES WELDED TO SHW PLATES, SHIM PATES TO BE 1-1/4' GREATER THAN JAMB DEPTH.
HEADER WELDS LEGATED .P FROM EACH .WAB & 3- MGM EACH SIDE OF VERDCAL MUWONS & O MIDPOINT
OF SPAN OF HERE ABOME DOORS WELDS ME M. 3/16' X 1' LONG. SHIM PATES ARE PROVIDED 8Y
O1HEM AFTER WELDING FRAME TO SHMS. CAULK WE BETWEEN FRAME AND STRUCTURAL MEL CHANNEL
WHERE SHIM PLATES TIRE VOO.
SIDE LITE AND TRANSOM FRAMES
MecoDoor
assaAslov
Page 5 of 15
0
Windstorm Frame Installation Instructions
F For Wse With FL 4553
1. DESIGN PRESSURE = +/- 60 PSF
IMPACT RATING = 35D FT-LBF
2. ALL FRAME PERIMETERS & HEADS OF
FASTENERS SEALED WITH SILICONE.
3. CORNER CONSTRUCTION = WELDED ONLY
4. ANCHORS = SEE CHART BELOW
5. FRAME DEPTH = 4" MIN. / 14" MAX.
16 GA. MIN.
6. STOP HEIGHT = 5/8' MIN.
7. FULL HEIGHT VERTICAL & 6' HORIZONTAL
MULLIONS MUST BE REINFORCED WITH
(2) 10-GAUGE X 3/4" X FRAME DEPTH
'C' CHANNELS INSTALLED BACK TO
BACK TO FORM SIMULATED 'I' BEAM.
IbI3,A
F0262
FRAME FACES
DIM.
DIM.
MAX. EXPOSED
GLAZING
"B"
"C"
GLAZED AREA
DIM. "A
MATERIAL
MAX.
MAX.
(Fn )
MIN.
MAX.
'GLASSLAM
SAFETY
PLUS 2
2"
4"
72"
94"
3354
LAMINATED
1
GLASS
SILICONE. 1 O/c 5@EL _S (18 ON HONEYCOMB, PMax) y BE. USED
I L CORE OR
POLYSTYRENE CORE PANELS (18 GP Min - IT GP Max) MAT ED USED IN LIEU OF
FROM AM. PANELS ARE WELDED. FRAME THE
WEIRS LOCATED UN THE FR SIDES 3' MA)(.
FROM EAGH EO. & 3' MAX. O.C. & ON THE TOP &BOTTOM 0' G. FROM EACH END &
WITH
12' ICON O.C. THE WEIRS ARE 41N. 1/4' WELDS % 1/2' LONG. PANELS ARE SEALED
WITH SILICONE.
ANCHORS & METHOD
OF ATTACHMENT
ANCHOR TYPE
LOCATION
EO - PIPE & SLEEVE
OR BUTTERFLY
WOOD BUCK
3/8' X 6' LAG SCREW
a JAMB
12' MAX. FROM SILL, 8' FROM HEAD & 20' O.C.
a HEAD
"2' FROM EACH VERTICAL MEMBER & 14' O.C.
0 SILL
2- FROM EACH VERTICAL MEMBER & 0 MIDSPAN
EO - PIPE & SLEEVE
BUTTERFLY0
MASONRY BUCK
BUCK
/8' X 6" EXPANSION SHELLS
0 JAMB
12' MAX. FROM SILL, 8' FROM HEAD & 20' O.C.
HEAD
' 2" FROM EACH VERTICAL MEMBER & 14' O.C.
0 SILL
2- FROM EACH VERTICAL MEMBER & a MIDSPAN
WIRE MASONRY OR
MASONRY 'T' - GROUTED,
WELDED TO STEEL HEADER,
EO P&S OR BUTTERFLY -
3 8' X 6" BOLTS
a JAMB
8' MAX. FROM EACH END & 15" O.C.
0 HEAD
"'WELDED TO STEEL CHANNEL HEADER
0 SILL
2' FROM EACH VERTICAL MEMBER & 0 MIDSPAN
WELDED TO STEEL BUCK
a JAMB
"`5' MAX. FROM SILL & 2].5MAX. O.C.
0 HEAD
-WELDED TO STEEL CHANNEL HEADER
0 SILL
2' FROM EACH VERTICAL MEMBER & 0 MIDSPAN
WOOD STUD
METAL STUD
(NO FLOOR ANCHORS)
a JAMB
0 HEAD
5" MAX. FROM SILL & 27.5" MAX. O.C.
"2" MAX. FROM EACH VERTICAL MEMBER & 14" O.0
0 SILL
2" FROM EACH VERTICAL MEMBER & 0 MIDSPAN
• FOR 6' & UP HEAD MEMBERS. FOR HEADS LESS TUN 6'. LOCATE ANCHORS 2" MAX. FROM EACH VERIM
MEMBER & a MIDPOINT OF SPAN.
—1/4" THICK MM. SHIM PLATES (2" WIDE X 7' LONG OR TO SUIT JAMB DEPTH) WELDED TO STEEL
CHANNEL & M%M6 WELDED TO SHIM PLATES SHIM PLATES TO BE 1-1/4' GREATER THAN JAMB DEPTH.
HEADER WEIRS LOCATED 3' FROM EACH JAMB & J' MOM EACH SIDE OF VERTC& MMLIONS & a MIDPOINT
OF SPAN OF HEAD ABOVE DOORS. WELDS ARE MIN. 3/16' X I' LONG. SHIM PATES ARE PROVIDED BY
OTHERS. LATER WELDING FRAME TO SHIMS, CAULK DIPS BETWEEN FRAME AND SRIUCTURN. STEEL CHANNEL
MERE SHIM PLATES ARE VOID.
BORROWED CITE FRAMES
McCO =
_ __ •
I DEPTH - 1/4" IT
0-GAUGE I0J50
0.750
ETAIL "A —A;
Page 6 of 15
Windstorm Frame Installation Instructions
F For bse With FL4553
GLASS MAY BE
INSTALLED ON
EITHER
SIDE OF THE
FIXED FRAME
STOP.
DOW CORNING
995 SILICONE
SAFETY GLASSLAM
�RB-78x1-1/2'
GLASSLAM
II
OVAL
TEK
HEAD
SAFETY PLUS I\
SCREW
DOW CORNING
f
995 SILICONE
1a 5/8'
5/8'
1/6' % 1/2'
CLOSED
`)�
3/8' X 1/2' CLOSED
CELL FOAM
TAPE
DOW CORNING
CELL FOAM TAPE
PET FLAP
995 SILICONE
(LAF
REQUIRED
PET
REQUIRED
CORNING
SILICONE
1.) BEFORE REMOVING THE REMOVABLE STOPS, USING A PENCIL, MARK
ALIGNMENT MARKS ON THE STOPS AND THE FRAME.
2.) UNSCREW THE #6 X 1-112' OVAL HEAD TEK SCREWS FROM THE REMOVABLE STOPS AND REMOVE THE
STOPS.
3.) WIPE THE FIXED STOP CLEAN AND THEN APPLY THE CLOSED CELL FOAM TAPE TO THE FIXED STOP.'
4.) IF THERE ISi PLASTIC RELEASE ON THE FOAM GLAZING TAPE, PULL THE PLASTIC RELEASE BACK ABOUT
2'.FROM EACH END OF THE FDA4 TAPE. PULL THE PLASTIC RELEASE ABOVE THE FIXED STOP SO IT CAN
BE GRASPED AFTER PLACING THEGLASSLAMON THE UNEXPOSED FOAM TAPE.
STEP 5—MAY REQUIRE THE ASSISTANCE OF ANOTHER PERSON TO HELP HOLD THE GLASSLAM IN PLACE.
5.) IF THERE IS PAPER RELEASE ON THE FOAM GLAZING TAPE, REMOVE THE PAPER RELEASE BEFORE
GLAZING. SPRAY THE EXPOSED FOAM TAPE WITH A MILD SOAP SOLUTION IMMEDIATELY BEFORE PLACING
THE GLASSLAM ON THE EXPOSED FOAM TAPE.
6.) PLACE GLAZING SHIMS, AS NEEDED, THEN SET THE GLASSLAM ON THE FOAM GLAZING TAPE.
7.) ADJUST HE GLASSLAM ASSEMBLY, AS NECESSARY, TO CENTER THE ASSEMLY IN THE OPENING.
B.) IF THE RELEASE IS PLASTIC, GRASP THE FREE END OF THE PLASTIC RELEASE, WHILE HOLDING THE
GLASSLAM TO KEEP IT FROM MOVING. THEN SLOWLY PULL THE RELEASE OFF THE FOAM TAPE THAT WAS
APPLIED TO THE FIXED STOP, PRESS THE GLASSLAM AGAINST THE FOAM TAPE.
9.) INSERT A PUTTY KNIFE BETWEEN THE PET FLAP AND THE FRAME RABBET. USING THE PUTTY KNIFE
PULL THE PET FLAP UP AND OFF THE FRAME RABBET.
10.) WHILE HOLDING THE PET FLAP BACK AWAY FROM THE FRAME RABBET WITH THE PUTTY KNIFE, USE A
CAULKING GUN TO APPLY DOW CORNING 995 SILICONE BETWEEN THE PET FLAP AND THE FRAME RABBET.
IMPORTANT: ENSURE THAT THE DOW CORNING 99S SILICONE FULLY WETS OUT OR COVERS THE PET
FLAP AND COMES IN CONTACF WITH THE FRAME RABBET.
11.) SLOWLY MOVE THE PUTTY KNIFE AROUND THE FRAME AHEAD OF THE CAULKING GUN AND APPLY THE
SILICONE AROUND THE ENTIRE OPENING BETWEEN THE PET FLAP AND THE FRAME RABBET.
12.) APPLY 1/8' X 112' CLOSED CELL FOAM TAPE TO THE REMOVABLE STOP.
13.) IF THERE IS PLASTIC RELEASE ON THE FOAM GLAZING TAPE, PULL THE PLASTIC RELEASE BACK
ABOUT 2' FROM EACH END OF THE FOAM TAPE. PULL THE PLASTIC RELEASE ABOVE THE REMOVABLE STOP
SO IT CAN BE GRASPED AFTER PLACING THE REMOVABLE STOPS AGAINST THE GLASSLAM.
14.) IF THERE IS PAPER RELEASE ON THE FOAM GLAZING TAPE, REMOVE THE PAPER. SPRAY THE EXPOSED
FOAM TAPE WITH MILD SOAP SOLUTION IMMEDIATELY BEFORE PLACING THE REMOVABLE STOPS AGAINST
THE GLASSLAM.
15.) USING THE ALIGNMENT MARKS, POSITION THE REMOVABLE GLASS STOPS AGAINST THE GLASS. IF STOPS
ARE TOD TIGHT LIGHTLY GRIND THE END OF STOP FOR ADDITIONAL CLEARANCE.
16.) INSTALL AND TIGHTEN THE 98 X 1-1/2' OVAL HEAD TEK SCREWS IN THE REMOVABLE STOPS. BE
CAREFUL NOT TO OVER TIGHTEN.
17.) IF THE RELEASE IS PLASTIC GRASP THE FREE END OF THE PLASTIC RELEASE TAPE AND SLOWLY
PULL THE PLASTIC RELEASE OFF THE FOAM TAPE.
18.) TRIM THE PET FLAP AS NEEDED.
19.)USING THE DOW CORNING 995 SILICONE OR OTHER HIGH QUALITY SILICONE, APPLY A SMALL CAP BEAD
OVER THE CLOSED CELL FOAM TAPE.
(Ccnversion. 1' = 25.4 nn, e.8., 1-3/4' = 44.45 nn) 9-217
07/01/15
HURRICANE RESISTANT FRAMES-GLASSLAM SAFETY PLUS II GLAZING INSTRUCTIONS
Meco Door
Page 7 of 15
Windstorm Frame Installation Instructions
For [)se With FL 4553
314' LEG OF'C CHANNELS
FULLY WELDED TO FRAME
FRAME FACE
CDNTINUOUSLY WELDED
CONTINUOUSLY WELDED ON
BOTH ENDS AT SEAMS
SEE NOTE 7
NOTE:
1. MULLIONS MUST RUN THROUGH HEADS, SILLS, OR JAMBS AND BE
REINFORCED WITH 10 GAUGE "C" CHANNELS (ITEM 10) IF EQUAL TO OR GREATER THAN
V IN LENGTH.
2. 10 GA. "C" CHANNELS MUST BE INSTALLED.BEFORE WELDING TOGETHER. OFFSET 3/4"
ON EACH END.
3. EQUALLY SPACED AT EACH END OF MULLION.
FRAME CONSTRUCTION AND MULLION DETAIL
"I" BEAM CONSTRUCTION DETAILS
Meco Door
AWAABLQY
Page 8 of 15
F0263
Windstorm Frame Installation Instructions
0 For Use With FL 4553
TFLSL TFLSL
* OPTION: ARCHED UNITS
LSL
LPSL
RSL
RPSL
TFRSL TF
2SL
P2SL
VARIES
WINDOW FRAME ABOVE FLOOR
TFLPSL
ARCHED FRAMES
TFLPSL
TFRPSL
SLOPED FRAMES
WINDOW FRAME ON FLOOR
ALTERNATE FRAME DESIGN
Mec0000r
AWAABMY
Page 9 of 15
F0282
Windstorm Frame Installation Instructions
' For Use With FL 4553
CONVENTIONAL FRAME CORNER ASSEMBLY
SLOTS FOR
CORNER TABS
SLOTS FOR
JAMB TABS
HEAD
[R TABS
JAMB IABJ
Install rubber silencers before
frame is setup to ovoid grout
plugging holes.
BEND CORNER TABS
TOWARD INSIDE OF
FRAME
CORNER
ASSEMBLY
z
BEND JAMB TABS
TOWARD OUTSIDE
OF FRAME
DRYWALL FRAME CORNER ASSEMBLY
#8 • 1/2'
PHSMS
JAMC
SQUARING THE FRAME
The installer should use wood spreaders,
a carpenters level and a carpenters square.
Set the frame in the desired location. Level
head and plumb jambs. Shim under jambs if
necessary.
• 1/2`
PHSMS
Bend Head
Tabs UP
CORNER ASSEMBLY
�
DOOR OP_ C AT HEAD 'I
SPREADER
Typical wood spreader must be square and made
from lumber at least 1' thick. Length of spreader
equals door opening width at the head. Cut clear—
ance notches for frame stops as shown. Spreader
must be nearly as wide as frame depth for proper
installation.
KO FRAME CORNERS
MecoDoor
ASSAABLOY
Page 10 of 15
Windstorm Frame Installation Instructions
r For Use With FL 4553
Pocket Provided F0283
for 1/2 or 5/8'
thick wall board
�
Flush Ntype
with � �stud —•{ 2'Weldedsnap METAL STUD "Z"
METAL STUD ANCHOR ANCHOR
Pocket provided
Pocket Provided for 1/2' or 5/8"
for 1/2� or 5/8' thick wall board
thick wall board _ \
p
I Flush p
Flush with 2,
with Welded stud _ I h'— ,•'
stud —4— Snap —in type
METAL STUD "Z" WOOD STUD ANCHOR
ANCHOR (Used also for METAL STUD Walls)
Pocket Provided
for 1/2 or 5/8'
thick wall board
r5/8, Tx I j D O
Welded 12' �— Snap —in type
WOOD STUD "Z" EXISTING OPENING ANCHOR
STRAP ANCHOR
EXISTING OPENING ANCHOR
STUD WALL FRAME ANCHORS
Meco Door
ASSAABWY
Page 11 of 15
Windstorm Frame Installation Instructions
For Use With FL 4553
Snop—in type
WIRE MASONRY ANCHOR
YOKE AND STRAP
MASONRY ANCHOR
EXISTING OPENING ANCHOR
x.
ti r
POURED IN
PLACE WALL
F0284 A
MASONRY "T" ANCHOR
Bend in field
to f,L
\� Snap —in type
MASONRY "T" ANCHOR
(ADJUSTABLE)
gar 4typ.
STANDARD
FLOOR ANCHOR
MASONRY WALL FRAME ANCHORS
MecoDoor
Page 12 of 15
Windstorm Frame Installation Instructions
For Use With FL 4553
FOR STEEL SHIM LOCATIONS
SEE "SIDE LITE TRANSOM FRAMES", PAGE 5 AND "BORROWED LITE FRAMES", PAGE 6
EXT
SHIM PLATE 1.25'
LONGER THAN
FRAME JAMB DEPTH
ATE
FRAME WELDED TO SHIM
WITH �6' x 1" LONG FLARE BEVEL
WELD BOTH SIDES OF FRAME
WITH E6018 ELECTRODES
AFTER WELDING FRAME TO SHIMS,
CAULK GAPS BETWEEN FRAME
AND STRUCTURAL STEEL MEMBER
WHERE SHIM PLATES ARE VOID. '
a MAX. THICK A-36 STEEL
SHIMS WELDED TO
STRUCTURAL BUILDING
MEMBER WITH FILLET WELDS
MEASURING 2" LONG AND
SIZED TO THE SAME
THICKNESS AS THE SHIM
PLATE USING E6018
ELECTRODES
WELD HOLLOW METAL FRAME
TO SHIM WITH )e" x 1" LONG
FLARE BEVEL WELDS, BOTH
SIDES OF FRAME USING E6018
ELECTRODES
r MAX. THICK, 2" WIDE A-36
STEEL SHIM PLATE(S), LENGTH
1.25" GREATER THAN FRAME
JAMB DEPTH
Xonversiom i' = 25.4 nn, e.g., 1-3/4' = 44.45 nn)
HURRICANE RESISTANT FRAMES —SHIM PLATE DETAIL
CCec0000r
9-214
12/07/12
Page 13 of 15
Windstorm Frame Installation Instructions
For Use With FL 4553
P381 AND 3E
12' LONG PIECE OF P381 APPLIED ON
LOCK JAMB DOOR RABBET
STARTING AT SILL.
REMAINDER OF JAMB IS P385.
'7P�r z50
ya�5r tae
PEMKO
PEMKO
P242
P261
PEMKO
�J5
PEMKO
312
S771
00
PEMKO 2008
NGTH OF P381 APPLIED ON
TOLD STARTING AT THE LOCK
REMAINDER OF THRESHOLD
WEATHERSTRIP IS P385.
�r.)5" n5
3- L_..11 5 r3^ E:rao
PEMKO PEMKO PEMKO
P266 P381 P385
7
•�r
_
PEMKO
PEMKO
S44
315CN
PEMKO
346C
so
WEATHER STRIP FOR WATER INFILTRATI❑N SINGLE DOORS PER
TAS DESIGN PRESSURE 50 PSF
F0305
WATER INFILTRATION PREPARATIONS SINGLE SWING
MecoDoor
AMAAB"
Page 14 of 15
Windstorm Frame Installation Instructions
' For Use With FL 4553
O P385
P385
P266 P266
P312�
6
S44
312
PAIR WITH
HOLLOW METAL
MULLION
PAIR WITH RIM EXIT
AND
HARDWARE MULLION
'73�r.Zy y3nr.186
PEMKO PEMKO
P242 P261
PERKO
312
S77112 771
12' LENGTH OF P381 APPLIED [IN BOTH
MULLION RABBETS STARTING AT THE
SILL. REMAINDER OF MULLION IS P385.
PEMKO PEMKO
PEMKO
P266 P381
PPj338855
r
PEMKO
PEMKO
S44
315CN
PEMKO 2008
s
[PEMK10
PEMKB P255
WEATHER STRIP FOR WATER INFILTRATION
PAIRS OF DOORS PER TAS 202 DESIGN PRESSURE 60 PSF
F0300
WATER INFILTRATION PREPARATIONS STANDARD SWING PAIR
C Ceco Door
ASSAAB"
Page 15 of 15
IUNDERWRITERS LABORATORIES FOLLOW-UP SERVICE PROCEDURE
DRAWN BY: BNR MANUFACTURING LOCATIONS PROJECT REF: TSO4CL57
Label for Windstorm Resistant Doors
pSS�f' EXTERIOR SWINGING DOOR R27575
Wlak
INACCORDANCE WITH ANSI/SDI—SHMA A250.13
STIFFNESS CLASS=GCecoOoor
IMPACT RATING : 350 FT—LBS
DESIGN LOAD RATING PSF ASSAABIDY
4YZ5 PRODUCT CONFORMS TO ASTM E33O/E1886/E1996 &
TAS-201. TAS-202. TAS-203 TEST PROTOCOLS 7000681
The label design has the following information:
1. UL classified logo
2. Ceco Door/ ASSA ABLOY logo
3. UL assigned Control Number 4YZ5
4. Complimentary classification (Classified Windstorm Resistant Door)
5. Stiffness Classification (1, II or III)
6. Design Load Rating & Impact Rating
7. ANSI/ASTMITAS Test Number References
S. Ceco part number (7000681)
Labels will be metal with holes for fastener attachment.
Windstorm Label Detail
FILE:
VOL:
SEC:
ILL:
R27575
1
2
9
I UNDERWRITERS LABORATORIES INC. FOLLOW-UP SERVICE PROCEDURE.
DRAWN BY: TTH I MANUFACTURING & SERVICE CENTER LOCATIONS I PROJECT REF: TS03CL61
Label for R'mdstorm Resistant Frames
_ eSSit EXTERIOR DOOR FRAME R27576 \
/ WUSL
IN ACCORDANCE WITH ANSI/SDI-BHMA A250.13
WINDSTORM RESISTANCE
IMPACT RATING : 350 FT-LBS
DESIGN LOAD RATING I PSF
ALSO CLASSIFIED IN ACCORDANCE WITH
4ZBI ANSI/ASTM E330, ANSI/AST. E18S.. AST. E1996.
TAS-201. TAS-202 cnd/er TAS-203 7nnn7AS
The label design has the following information:
1. UL classified logo
2. Ceco Door I ASSA ABLOY logo
3. UL assigned Control Number (4ZB1)
4. Complimentary classification (Windstorm Resistant Frame)
S. Design Load Rating & Impact Rating
6. ANSIIASTMiTAS Test Number References
7. Ceco part number (7000746)
Labels will be metal with holes for fastener attachment.
rssuE I C=Ceco Door I FILE: R27576
ACCA A13IfIW VOL: 1
WINDSTORM LABEL DETAIL (FRAMES)
SEC:
ILL:
Windstorm Door Installation Instructions
Qt I wiprnlimiy For -Use With FL 4553
Stiffness Class I
Impact 350 ft-lbs
st *Max.
51,
''Latch
Door
olfig ration
i �` Hardware Type .
Mi6LAih,TfirqwQq)`Min
,
.
'Medzilli6i'n"
-I
Ultr;j =
-Inswing/
3D x-7U
C
Mortise'LoSingle
Regent
outswing
T
'150��
630,
not
drlieg'a-
r
,PueqW.
-
Medallion.
k
CV.1indrical Loc X,
Ultra
IfisW!ng/,
36 i 76
18
4.
Olt-
ortise--
'Lockw/dpad.
Reg, dn" t
Sirigle�
brnega
'Oub§win,g-�T'
Interconnected o
-ck
Medallion
Le ion'
30 x 80
13/40mortise; I"deadbolt,w/deadbolt,
Rim
16
W
-
n/a r1Mfi6rti6al rod exitExit,
720,
Vertical Rod
Regent'
Exit
ega,-
ry
Medallion
CylindricalLock,
Legion,
cyl'indncal
Mortise Lock
- -
:30 x 70
T-
'i ,
Mortise, lock
'(Deadbblt not
Regent:
mg
tingle,
18,
60,
.3/4
m6rtiid vertl 1:regwred
630
mega:-
Exit, RiW<,
T,
Vertical Rod Exit',-
Medallion
Legion,,
TT,
Mortise Lock
v, Ultra
40-x 80
` , -' I q,
Z � -
I ortsp,,I-:d
w/dea it
�'R
5�
Regent
Outswi ng �. .
-"
Single
16
f.-76
I 1 11
im/vefti&al rodexiit�,'
T T,
rn Exit, Vertical'.
Rod. Exit
Fuego
i Mortise Lock
Medallion
A.",
ea o(alive)
Legion '.�
- - - T
iff d Olt
3/ mortise;- a
U its
ultr-
, 1 0
80 x,80
P
-
7b-
�,rs
"i � 4 :, , I
uk,�fface t,
'. , J
1i2d -
n iv 16
rifik r! M
X Vertical Rod'
me k
E Rjrh Exit x'
Exit,
'Mullion
Stiffness Class; I Continued
on
nenWiliadif
*Glass lights may limit design loads. See details to follow for additional information.
"Louvers are excluded from use with Trio and Trio-E Doors
Optional All Door Series - 1/211 max. diameter cutout for viewer.
EaReco-Door Page I Copy
0"e-
ASSAABLOY
Windstorm Door Installation Instructions
. For Use With FL 4553
Stiffness Class I Continued
Impact 350 ft-lbs
-A!"
ratio
ikx.f-
kX,
Ii.,
1,
i 7
si "n",
'Mi n.'LatC
,Lock Sid
Y
It
TYP6,
1i
I
Mize
Gauge
Load
-2
t (in)''-
Mi ni'lAtih
'S
strength (lb
P
deadbolt
Mortise Lock`
66tswing,
80x8O
-9�rncirt
mortise
adb6if,(6- e
(active)
Fuego.
Pair
16
t/-,70
Surface B61
Bolts
ftiU ce
bolt 4 rfa
-
7
inactive
Medallion,�
Inswing/
40ix"80
" t"', 'z
Multi Point Locle-�,
Redefif"
I .. 1
-butswing
1 14
3/4 mortise I- i:le_;idb6l't
�460,
.,Single
+/ �50
impe zil
MedallionM
4 mortise, 1" deadbolt
61 Point Lock
Inswing/
86x go
iv e
Imperial'11
utswin g
1/4" Sl.lr�ee bolt,
Surface
-"Trio'
-wing
3
,Cylindncal
-
, , firidn'tal" 1A, c
y
Lock,
Ins
- 11.
9�k;?,o
1B --�
I
L 100
, 1, 3/4ff mortise lock-
1050--',
Mortise Lock w/
Trio-E�,
Outsvilng-,,,-I
. .. ...
'd f6h'
e-a4bolt i6ni
0:
**Tri I
06tswing
30'3(,76
'Singl6,
iOO
ex it,
I 1050
"-Rim,E5d!; -
,Trl
'3�4",Hffi'
7 ,
"I Cy 1i I n n Ck`x_
d
1h"
_rLise,,
cylindricalDeadlock
-*-rrlo
Inswing/
"
66 x 70
+/7 70
1 deadlock
I735_,
function;
active)Trio-E
outswing
0al.
�
3/4'moftislock
FlushBolt or
Surface '6o'lt,;`(1n-,
;active -),,
'Trio
Inswing/
40 X 80
�Slh*
18
+1- 70
d a
Y.20 cylin nc
�','l 120
Mortise Lock vv/4t,
6
J0 �E��
Outs Wing
'Single
3/, 1 -
rl lock
4 mortise
�11
I I
-�Z-14e660t.
,
nction I fu
�TTnojio�'
- �7 11,
40 x 80
z
X�
-H."'
Rim Exit
Outswing'
77
Single
Sing
18
m I
ex
3/a" rirriexit' x 3/a" HM�,
`-Aim
*Trio
exit
X Ha rdware Mullion
80 x 80
I I
1
+/
1120
I Trio-E -I
W
Outs ing,
Fair
314" Vertical Rod Exit X
Vertical Rod Exit
ca RoA Exlt:
- Cyfin&iciii'Cocktk
"--t
t7,
4Mor If, tise Lock.,
**Trio:
80. x 8.0
"
cylindrical I/z
w/Deadbolt-, ,
Trio-E
Ihswing/.
.1
Pair
18
+/-70
i'd66dl66k
1 20-
_ _ _t __ _ t_
Function (active):
Outswing
.314ff Mortise lock'
-
r
Flush Bolt .off';.:,.
s6rtg6i'Bolt, �
Inactive
*Glass lights may limit design loads. See details to follow for additional information.
"Louvers are excluded from use with Trio, Trio-E. Glass lights and louvers are excluded
from use with 150 PSF Doors.
Meco Door
I Page 2 of 18
AWAABLOY
Windstorm Door Installation Instructions
• For. Use With FL 4553
Stiffness Class II
*Max
L
Lock SrdeL
/'
Door
Max
Min
Design
Mm Latch
Confguration
Min. Latch Throw (m)
Hardware .Type
Type,
YP
Size
Gauge
9
Load„
Strength
_
Itif �
x..
_
Cylindrical Lock,
Imperial
Inswing/
30 x 70
18
=� /2 cylindrical
630
Mortise Lock
Versadoor
Outswing
Single
-
+/-fi0
h
3/a' mortise
(Deadbolf-not-
re uired =
iylmdncal �1"deadlock
Cylmdncal Lck oz
Impenah
Inswing/
30x 70
3la". mortise'"i deadbolt
Deadlock, Nlortis`'e
Versadoor
: Outswing
Single
18
+/ 70
�/;' act latchl ; deadbolt
735
Lock w/deadbolt;
(ICL)II-Interconnected
n'
<+ lock?'
''Imperial`
Inswing/
^..
30 x 80
18
+/- 60
3
/a-- mortise 1 deadbolt
720
Mortise Lock ~`
Versadoor
Outswin
,Sin le
�^- -�,.,� . ,
�t w deadbolhZ:
wt
`3.'a
"x
f V
Cylmdncal 1 ock,
�/z cyludncal
-
Mortise Lock
Imperial
30x 70
" 3/4 mortise
''
'�(Deadboltnot
Versadoor
Outswing
Single
18
+/- 60
n/a mortise/rim/vertical
630
,
regwred) Mortise.
rod exit
Exit, Riml-xlt,ia
-Vertical Rod licit`
Mortise
;Impena(
'
30 x 80
,. `
3/4' mortise 1" deadbolt
'
,Lock
w/deadbolt- Wm'..
Versadoor
Outswing
Single
18
+/- 60
- • -
n/a nm/vertical rod_exi[
720
Exit Vertical Rod .
F5at�'^
Imperial
Insw"ing/
40 x 80
Mortise Lock
Versadoor
=: - Outswin
Sin le
.:- 16
+%-70
3/a'mortise,ii deadbolt
1i20
-w/deadbolt :.
'
Mortise Lock i
�Impernal
�:,
40""x 80
3/a" mortise 1" deadbolt
"
w/deadbolt
Versadoor
Outswing
Single
16
}/- 70
n/a rim/vertical rod exit
1120
Rim bat Vertical�
Rod`Ex -
' Imperial
Outswing
60 x 70
18
+/= 60
= n/a rim exit
630
u
Rim Eic Mullion,
Versadoor
.
=�
Pair'.
_. ,>
r
'x
�>
Mortise Lock .
'
Imperial
.,
8080
3/a" mortise 1 deadbolt f
" w/deadbolt
Versadoor
Outswing
:
Pair„
16 -
+/- 70
^--
1+/a" surra_ce bolt
1120
(actrve)f/ Surface_
Bolts. inactive
Im
Inswing/ '
40x80
**
'1
Multi PomtLock'=
p enal
Outswin
Single'
14
_- 150
'3/4" mortise deadbolt
'
2400
Multi Point"Lock
w/deadbolt
Imperial
Inswing)
80 x 80
14
**
3/
a" mortise, l( deadbolt/
2400
(Active)
Outswing
Pair
+/- 150
,
1 /a surface bolt
Surface,Bolts
Inactive
*Glass lights may limit design loads. See details to follow for additional information.
**Louvers are excluded from use with Trio, Trio-E. Glass lights and louvers are excluded
from use with 150 PSF Doors.
MecoDoor
Page 3 of 18
ASSA ABIAY
Windstorm Door Installation Instructions
' For Use With FL 4553
Vertically Stiffened Door
CONSTRUCTION DETAILS
HINGE :DNIOMOEMENT
GAGE CLOSER
PREPARATION GAGELOSED0 2 3 5 B
(OPTIONAL)
RBERGLSS INSULATION BETWEEN
STIFFENERS -MINIMUM
DENISTIY 0.0.5 PCF
BOTTOM -
FACE SHEET
TOP FACE SHEET
HINGE
EDGE LOCK
RECESSED 16 GAGE BOTTOM CHANNEL IS
SPOT WELDED TO BOTH FACE SHEETS
n
VERTICAL SECTION
THRU BOTTOM OF DOOR
LOCK
EDGE
LOCK AND "GE EDGES PPE BEVELED 1/6' IN R' (1:16)
MWE EDGE OPPONAL
RECESSED 16 GAGE TOP CHANNEL
IS WELDED TO BOTH FACE SHEETS
18 CAGE CAP CHANNEL IS SCREWED
TO INVERTED CHANNEL (OPTIONAL).
CLOSER REINF.
14Gav6'K20'
VERTICAL SECTION
THRU TOP OF DOOR
STANDARD: CENTER EDGE SEAM
VERTICAL EDGE SEAMS ARE WSIBLE WITH 18 GAUGE
BACKUP CHANNEL FULL HEIGHT OF DOOR
WITH OPTIONAL BONDO FILLED OR WELDED
SEAMLESS EDGE AVAILABLE
1-3/4.
OPTIONAL: TAB & SLOT MECHANICAL INTERLOCK
WELD SEAMED EDGES GROUND
SMOOTH ARE OPRONAL
HORIZONTAL SECTION
THRU LOCK EDGE
Note: 1. Drawing Not To Scale
22 GAGE FORMED STEEL STIFFENERS
(20 GAGE AND GALV STEEL OPTIONAL)
POSITIONED NOT MORE THAN 6' APART
AND SPOT WELDED TO BOTH FACE
SHEETS AT 5' O.C. MAX
r��=n
HORIZONTAL SECTION
THRU VERTICAL STIFFENER
Medallion Steel -Stiffened Core Door Details
C=-CecoDoor
Page 4 of 18
Windstorm Door Installation Instructions
For- Use With FL 4553
TRIO DOOR LOCK EDGE IS BEVELED 1/8- IN 2-
CONSTRUCTION DETAILS HINGE EDGE IS PERPENDICULAR TO FACES
HINGE BACKSET IS 1/4- (VARIES PER CONDITION)
14 GAGE CLOSER
REINFORCEMENT INVERTED (16 GAGE MIN.. 14 GA MAX.) TOP
HINGE
(OPTIONAL) CHANNEL SPOT OR PROJECTION WELDED
PREPARATION
TO TOP & BOTTOM SKIN
16 GAGE CAP CHANNEL IS SCREWED
TO INVERTED CHANNEL (OPTIONAL).
•BETWEEN
BOTTOM
STIFFENERS�TION
FACE SHEET
DENSITY : 1.8-2.0 LBS/CUBIC FOOT
22 GA
VERTICAL SECTION LINER
THRU TOP OF DOOR
r LOCK
TOP FACE SHEET
LOCK PREPARATION
FACE SHEETS
18 GAGE CRCO STEEL (STANDARD)
16 GAGE CRCO STEEL (OPTIONAL)
GALVANIZED (A60) STEEL (OPDONAL)
CONTINUOUS BEAD OF STRUCTURAL
ADHESIVE BOTH oa�DMIN
16 OR 18 GA (WELDING OPTIONAL)
VERTICAL EDGES ARE WELDED THE
FULL HEIGHT OF DOOR AND DRESSED
SMOOTH TO OBTAIN COMPLETELY
SEAMLESS HINGE AND LOCK EDGES.
22 GA
LINER I VERTICAL EDGES ARE
CECO'S STANDARD
HORIZONTAL SECTION TAB & SLOT
THRU LOCK EDGE MECHANICAL INTERLOCK
STANDARD 22 GAGE (20 or 18 GAGE OPTIONAL)
FORMED STEEL STIFFENERS, POSITIONED
NOT MORE THAN 6' APART, AND WELDED
TO 22 GAGE LINER (5- O.0 MAX.).
22 GA LINER
22 GA STIFFENER
HORIZONTAL SECTION
THRU VERTICAL STIFFENER
INVERTED (18 GAGE MIN., 14 GA MAX.) BOTTOM
CHANNEL SPOT OR PROJECTION WELDED
TO TOP & BOTTOM SKIN
22 GA
LINER JT--pR
5 8- MIN. -
1• MAX' VERTICAL SECTION
THRU BOTTOM OF DOOR
Trio Steel -Stiffened Core Door Details
Ca:CecoDoor
ASSAABLIDY
Page 5 of 18
Windstorm Door Installation instructions
For 'Use With FL 4553
TRIO-E DOOR LOCK EDGE IS BEVELED 1/8' IN 2'
CONSTRUCTION DETAILS HINGE EDGE IS PERPENDICULAR TO FACES
HINGE BACKSET IS 1/4' (VARIES PER CONDMON)
14 GAGE CLOSER
REINFORCEMENT
INVERTED (16 GAGE MIN., 14 GA MAX.) TOP
HINGE
(OPTIONAL)
CHANNEL SPOT OR PROJECTION WELDED
PREPARATION
TO TOP & BOTTOM SKIN
'POLYURETHANE INSULATION
BETWEEN STIFFENERS
18 GAGE CAP CHANNEL IS SCREWED
DENSITY : 1.8-2.0 LBS/CUBIC FOOT
TO INVERTED CHANNEL (OPTIONAL).
BOTTOM
FACE -SHEET
il
22 GA
VERTICAL SECTION LINER
THRU TOP OF DOOR
K
EDGE
16 OR 18 CA (WELDING OPTIONAL)
VERTICAL EDGES ARE WELDED THE
FULL HEIGHT OF DOOR AND DRESSED
SMOOTH TO OBTAIN COMPLETELY
SEAMLESS HINGE AND LOCK EDGES.
22 GA 11-3/4'
LINER VERTICAL EDGES ARE
CECO'S STANDARD
HORIZONTAL SECTION TAB & SLOT
THRU LOCK EDGE MECHANICAL INTERLOCK
TOP FACE SHEET
STANDARD 22 GAGE 18 GAGE OPTIONAL)
FORMED STEEL STIFFENERS,
POSITIONED
NOT MORE THAN 6' APART, MODNDWELDED
TO 22 GAGE LINER (5' O.0 MAX.).
22 GA LINER
LOCK PREPARATION 22 GA STIFFENER
HORIZONTAL SECTION
THRU VERTICAL STIFFENER
FACE SHEETS
18 GAGE CRCO STEEL (STANDARD)
16 GAGE CRCD STEEL (OPTIONAL)
GALVANIZED (A40) STEEL (OPTIONAL)
N=
OPTIONAL
CONTINUOUSBEAD OF STRUCTURAL
ADHESIVE APPLIED TO BOTH
FLANGES OF BOTTOM SKIN
INVERTED (18 GAGE MIN.. 14 GA. MAX.) BOTTOM
CHANNEL SPOT OR PROJECTION WELDED
TO TOP & BOTTOM SKIN
22 GA
LINER
5 8' MIN.
1 MAX. VERTICAL SECTION
THRU BOTTOM OF DOOR
Trio-E Steel -Stiffened Core Door Details
MecoDoor
Page 6 of 18
Windstorm Door Installation Instructions
(See Section "E" of R3791 �
Volume 1 for Hinge Options)
For Use With FL 4553
Glazed Trio/Trio—E
CONSTRUCTION DETAILS
14 GAGE CLOSER
REINFORCEMENT
REQUIRED WITH RIM EXITS
'POLYURETHANE INSULATION
BETWEEN STIFFENERS
DENSITY : 1.8-2.0 LBS/CUBIC FOOT
LOCK EDGE IS BEVELED 1/8- IN 2-
HINGE EDGE IS PERPENDICUV TO FACES
HINGE BTCKSET IS I/C. (VARIES PER CONDITION)
LOCK
EDGE
TOP FACE HE (see Section "F"&
of R3791 Volume 1
for Lock Options)
TOP FACE SHEET
FACE SHEETS
18 GAGE CRCD STEEL (STANDARD)
18 GAGE CRCO STEEL (OPTIONAL)
GALVANIZED (AGO) STED. (OPTIONAL)
INVERTED (16 GAGE MN., 14 GA MAX.) TOP
CHANNEL SPOT OR PROTECTION WELDED
TO TOP & BOTTOM SKIN
19 GAGE CAP CHANNEL IS SCREWED
TO INVERTED CHANNEL (OPTIONAL).
M—
22 GA
VERTICAL SECTION LINER
THRU TOP OF DOOR
16 OR 18 W (WELDING OPTIONAL)
VERTICK El EDGES ME WDEO THE
FULL HEIGHT OF DOOR AND DRESSED
SMOOTH TO OBTAIN COMPLETELY
SEAMLESS HINGE AND LOCK EDGES.
22
LINGA ER VERTICAL EDGES ARE
CECO'S STANDARD
HORIZONTAL SECTION , TAB & SLOT
THRU LOCK EDGE MECHANICAL NTERLOCK
US BGe OF STRUCTURAL
APPUm To BOTH
OF B070M SKIN
D0323
STANDARD 22 GAGE (20 or 18 WE OPTIONAL)
FORMED STEEL SOFTENERS. POSITIONED
NOT MORE THAN r MART. AND MOOD
TO 22 WE EVER (5 O.0 MAX.).
22 GA LINER
22 GA STIFFENER
HORIZONTAL SECTION
THRU Trio—E VERTICAL STIFFENER
STANDARD 22 WE (20 or 19 WE OPTIONAL)
FORMED STEEL STIFFENERS. POSITIONED
NOT MORE THAN 6' MART. MD WELDED
TO 22 GAGE UNER (5' O.0 MAX.).
22 GA LINER
22 GA STIFFENER
HORIZONTAL SECTION
THRU Trio VERTICAL STIFFENER
INVERTED (18 GAGE MIN.. 14 GA. MAX.) BOTTOM
CHANNEL SPOT OR PROJECTION WELDED
TO TOP & BOTTOM SKIN
L 22 GA
LINER
5 8- MIN. r
I' MAX. VERTICAL SECTION
THRU BOTTOM OF DOOR
Glazed Trio/Trio-E Core Door Details
(Available with Rim Exit or Vertical Rod Only)
MecoDoor
Page 7 of 18
Windstorm Door Installation Instructions
For -Use With FL 4553
LOCK EDGE IS BEVELED 1/8' IN 2' (1:16)
POLYSTYRENE DOOR SOUARE EDGE OPTIONAL
CONSTRUCTION DETAILS INVERTED (16 GAGE MIN., 14 G4 MAX.) TOP
CHANNEL SPOT OR PROJECTION WELDED
TO TOP & BOTTOM SKIN
HINGE
PREPARATION
BOTTOM
FACE SHEET
D0255B
14 GAGE CLOSER
REINFORCEMENT
(OPTIONAL)
POLYSTYRENE CORE:
11b/Tt'UL LISTED
(ASSEMBLE WITH ADHESIVE
APPLIED TO BOTH SIDES).
18 GAGE CAP CHANNEL IS SCREWED
TO INVERTED CHANNEL (OPTIONAL).
CLOSER REINF.
14GA x 20' LONG
(Optional)
VERTICAL SECTION
THRU TOP OF DOOR
VERTICAL EDGES ARE CECO'S STANDARD
TAB k SLOT MECHANICAL INTERLOCK
WELD SEAMED EDGES GROUND
SMOOTH ARE OPTIONAL
I I I I T
I I I I
OPTIONAL: CENTER EDGE SEAM
VERTICAL EDGES ARE CONTINOUSLY WELDED WITH
18GA MINIMUM BACKUP ANGLE FULL HEIGHT OF
DOOR AND DRESSED SMOOTH TO OBTAIN SEAMLESS
HINGE h LOCK EDGES
I I I _
I I 1 1—IaI/4
1
HORIZONTAL SECTION
THRU LOCK EDGE
INVERTED (18 GAGE MIN., 14 GA. MAX.) BOTTOM
CHANNEL SPOT OR PROJECTION WELDED
TO TOP k BOTTOM SKIN
1-
8 8' MIN.
1' MAX.
Polystyrene Core Door Details
MecoDoor
_ is
VERTICAL SECTION
THRU BOTTOM OF DOOR
Page 8 of 18
Windstorm Door Installation Instructions
. For Use With FL 4553
Honeycomb Core Door
CONSTRUCTION DETAILS LOCK EDGE IS BEVELED 1/8' IN 2' (1,16)
SQUARE EDGE OPTIONAL
murr
D023BB
INVERTED (16 GAGE MIN., 14 GA. MAX.) TOP
CHANNEL SPOT OR PROJECTION WELDED
TO TOP L BOTTOM SKIN
18 GAGE CAP CHANNEL IS SCREWED
TO INVERTED CHANNEL (OPTIONAL).
CLOSER REINF.
14GA. x 20' LONG
(OptionAD
VERTICAL SECTION
THRU TOP OF DOOR
LOCK VERTICAL EDGES ARE CECO'S STANDARD
EDGE TAB L SLOT MECHANICAL INTERLOCK
WELD SEAMED EDGES GROUND
SMOOTH ARE OPTIONAL
1-3/4'
OPTIONAL- CENTER EDGE SEAM
VERTICAL EDGES ARE CONTINOUSLY WELDED V/RH
18GA MINIMUM BACKUP ANGLE FULL HEIGHT OF
DOOR AND DRESSED SMOOTH TO OBTAIN SEAMLESS
HINGE h LOCK EDGES
—T9
HORIZONTAL SECTION
THRU LOCK EDGE
INVERTED (18 GAGE MIN., 14 GA. MAX.) BOTTOM
CHANNEL SPOT OR PROJECTION WELDED
TO jTOP L BOTTOM SKIN
J_
5/B' MIN.
1' MAX. VERTICAL SECTION
THRU BOTTOM OF DOOR
Honeycomb Core Door Details
C=—CecoDoor
Page 9 of 18
ASSA ABL.QY
Windstorm Door Installation Instructions
For Use With FL 4553
Polyurethane Foam Core Door
CONSTRUCTION DETAILS LOCK EDGE IS BEVELED 1/8' IN 2' 016)
SQUARE EDGE OPTIONAL
INVERTED (16 GAGE MIN., 14 GA. MAX.) TOP
CHANNEL SPOT OR PROJECTION WELDED
TO TOP B BOTTOM SKIN
HINGE 14 GAGE CLOSER 18 GAGE CAP CHANNEL IS SCREWED
PREPARATION REINFORCEMENT
TO INVERTED CHANNEL (OPTIONAL).
(OPTIONAL) CLOSER REINF.
14GA. x 20" LONG
(OPti.n.D
PDLYURETHANE FOAM CORE
VERTICAL SECTION
THRU TOP OF DOOR
9 BOTTOM LOCK VERTICAL EDGES ARE CECO'S STANDARD
FACE SHEET EDGE ,, .p TAB 6 SLOT MECHANICAL INTERLOCK
WELD SEAMED EDGES GROUND
SMOOTH ARE OPTIONAL
` p
1-3/4"
EMBOSSED SKINS OPTIONAL. CENTER EDGE SEAM
OPTIONAL 4
VERTICAL EDGES ARE CONTINOUSLY WELDED WITH
9 18GA.MINIMUM BACKUP ANGLE FULL HEIGHT OF
TOP FACE SHEET DOOR AND DRESSED SMOOTH TO OBTAIN SEAMLESS
HINGE @ LOCK EDGES
1-3/4'
HINGE
EDGE LOCK PREPARATION HORIZONTAL SECTION
THRU LOCK EDGE
INVERTED (18 GAGE MIN., 14 GA. MAX.) BOTTOM
CHANNEL SPOT OR PROJECTION WELDED
TO TOP III�M& BB(O\r�TTOOMM1111 SKIN
'p 5/84 MIN.
1' MAX. VERTICAL SECTION
D 0 2 3 7 B THRU BOTTOM OF DOOR
Polyurethane Core Door Details
CC=Door
�-� Page 10 of 18
ASSA ABLAY
HINGE
PREPARATION
BOTTOM
FACE SHE
HINGE
EDGE
Windstorm Door Installation Instructions
For Use With FL 4553
Mineral Core Door
CONSTRUCTION DETAILS
14 GAGE CLOSER
REINFORCEMENT
(OPTIONAL)
TOP FACE SHEET
LOCK
D0262B
US GYPSUM
FIREDOOR COREBOARD
Assemble With Adhesive
pplied To Both Surfaces)
LOCK
EDGE
1�
LOCK AND MNM EDGES ARE BWELED 1/8' IN E' (1:16)
SQUARE EDGE 0PR0NAL
RECESSED 16 GAGE TOP CHANNEL
IS WELDED TO BOTH FACE SHEETS
18 GAGE CAP CHANNEL IS SCREWED
TO INVERTED CHANNEL (OPTIONAL).
3/16�
CLOSER REINF.
/ 14Goz6"z20'
VERTICAL SECTION
THRU TOP OF DOOR
STANDARD: CENTER EDGE SEAM
VERTICAL EDGES ARE CONTINOUSLY WELDED WITH
ISGA MINIMUM BACKUP ANGLE FULL HEIGHT OF
DOOR AND DRESSED SMOOTH TO OBTAIN SEAMLESS
HINGE & LOCK EDGES
4'
OPTIONAL: TAB & SLOT MECHANICAL INTERLOCK
WEw
SM
.
HORIZONTAL SECTION
THRU LOCK EDGE
RECESSED 16 GAGE BOTTOM CHANNEL IS
SPOT WELDED TO BOTH FACE SHEETS
/
3/16"
VERTICAL SECTION
THRU BOTTOM OF DOOR
Mineral Core Door Details
Meco =
Page 11 of 18
-1.656'
1.500
.625'
Windstorm Door Installation Instructions
For4Use With FL 4553
•,GLAZING (OPTIONAU
1/4' MAKROL12N POLYCARBONATE
SHEET BY SHEFFIELD PLASTICS
TYPE I VISION LIGHTKIT
—SEE LIMITATIONS BELOW
N
0.750• ni-
' � 33 1/2'
MAX.
NOTE: EXPOSED
SURROUND CHANNEL GLASS
LENGTH IS EQUAL TO CUT-OUT
IN DOOR FOR VISION LIGHT KIT.
GI
LA•
BE GLAZED WITH ➢OW CORNING
995 SILICONE
22 1/2'
MAX
EXPOSED
GLASS
MULTIPLE KITS
NOT ALLOWED
.4650' -
.1875'
3LAZING SHIMS
AS NEEDED
2'
,GLAZING
GLASSLAM 'SAFETY PLUS 2
LAMINATED GLASS
TYPE 2 VISION LIGHT KIT
'SEE LIMITADONS BELOW-
24'
MAX
-+iMIN EXPOSED
�I GLASS
6' MIN I
MAX. F]
GLASS
DESIGN LOAD = +/- 60 PSF DESIGN LOAD = +/- 60 PSF
IMPACT RATING = 350 FT _BF IMPACT RATING = 350 FT LBF
NOT AVAILABLE WITH TRIO OR TRIO-E
VISION LIGHT KIT DETAILS NOTES,
1) 1/8 x 112 x PERIMETER OF VISION LIGHT KIT
CLOSED CELL FOAM TAPE PER VISION LIGHT
VISION LIGHT 2) 66 K 1 1/4' OVAL HEAD TEK SCREW -
CORNER WELD MAXIMUM SCREW HOLE SPACING IS 9.75' ON CENTER
DETAIL 3) GLASSLAM SAFETY PLUS 2 LAMINATED GLASS
O O/ ( 4 SPOT WELDS 4) IS GA (.043) MIN. TYPE 2 VISION LIGHT KIT
AT EACH CORNER ) 5) 14 CA 4G68) MIN. PIECES SURROUND CHANNEL
q PER VISION LIGHT
6) 1/4' MAKROLDN POLYCARDCNATE SHEET
D0254
Applied Glass Kit Details
Meco Door
Page 12 of 18
ASSA ABIAY
GLAZII
AS
Windstorm Door Installation Instructions
For Use With FL 4553
W CORNING
5 SILICONE
•G
GLASSLAM SAFETY PLUS 2
LAMINATED GLASS
TYPE 2 WSIONLIGNTKIT
'SEE LIMITATIONS BELOW -
32'
MAX
I6" EXPOSED
1-MIN GLASS
6",MIN _
42"
MAX.
EXPOSED
FE
GLASS
MULTIPLE KITS
NOT ALLOWED
DESIGN LOAD = +/- 70 PSF
IMPACT RATING = 350 FT LBF
D0322
VISION LIGHT KIT DETAILS
VISION LIGHT
CORNER WELD
DETAIL
( 4 SPOT WELDS
AT EACH CORNER )
4<%
GLASSLAM SAFETY PLUS 2
LAMINATED GLASS MUST
BE GLAZED WITH DOW CORNING
995 SILICONE
NOTES:
1) 1/8 x 1/2 x PERIMETER OF VISION LIGHT KIT
CLOSED CELL FOAM TAPE PER.VISION LIGHT
2) 16 X 1 1/4' OVAL HEAD TEK SCREW -
MAXIMUM SCREW HOLE SPACING IS 8.250' ON CENTER
AND 3.5' MAX. FROM ENDS
3) GIASSLAM S4FETY PLUS 2 LAMINATED GLASS
4) 18 GA. (.043) MIN. TYPE 2 VISION LIGHT KIT
5) 20 GA (.032) MIN. GAGE SURROUND CHANNEL
Applied Glass Kit Details Trio/Trio-E
MecoDoor
Page 13 of 18
0
Windstorm Door Installation Instructions
` For Use With FL 4553
TYPE "A"
i"X1"
Foam Tape —
5Do"
.625
4" A4ox.
2 3/4"
D0256
TYPE "B"
X f"
Foom Tape ---�
#8 X 1 1" Phil. F.H.
TEK Screw
�Spotwelds 3" Max.
From End & 12" Max.
On Center
�SGotweids i" Max.
From End & 8" Max.
On Center
.500'
A X J" Double —
Sided Tape (OPTIONAL)
NOTES:
1) Glass is 1/4" Makrolon Polyearbonate
2) Multiple kits not allowed
3) N/A Trio/Trio—E or Impedal/Versadcor
#8 X 1 1" Phil. F.H.
TEK Screw
Spotwelds a" Max.
From End & 8" Max.
On Center
22"
MAX
6 EXPOSED
MIN GLASS
6" MIN
33 1/2"
MAX.
EXPOSED
GLASS
DESIGN LOAD = +/- 60 PSF
IMPACT RATING = 350 FT LBF
Flush Welded Glass Kit Details
Polycarbonate Glazing Instructions
Meco Door
Page 14 of 18
Windstorm Door Installation Instructions
For Use With FL 4553
Polycarbonate Glazing Instructions
TYPE "A"
375" 1" X }
]- X }- Foam Tope —
Foam Tape
#8 X 1 j" Phil. F.H.
TEK Screw Spotwelds 3' Max.
From Max.
End & 12" .500"
.500' On Center
15" Spolweltls Vex. 75D"/}
From End & A' Max. X J" Double J
On Center Sided Tape
—�I (Not Required)
1/8' x 12" I / 6 X 1 Oval Head
Foam Tape�l zt6" TEK Screw
TYPE 'B"
420'
SB X 1 i' Phil. F.H.
TEK Screw
i
Spotwelds i" Max.
From End & 8" Max.
On Center
GWIN" (OPTIONAL)
1/4' IAAKROLON POLYCARBONAIE
SHEET BY SHEFFIELD PLASTICS
TYPE 1 vMWUGHTff
1) BEFORE REMOMNG THE REMOVABLE STOPS, CHECK TO BE SURE THERE ARE SCREWS IN EVERY HOLE. IF A SCREW
IS MISSING AND THE MATERIAL BELOW HASN'T BEEN DRILLED, THEN PRE —DRILL HOLES WITH CORRECT BIT FOR THE
SCREW SIZE. DO NOT REMOVE STOPS.
2) USING PENCIL, MARK ALIGNMENT MARKS ON THE REMOVABLE STOPS (AND THE DOOR IF TYPE I KIT).
3) UNSCREW THE TEK SCREWS FROM THE REMOVABLE STOPS AND REMOVE THE REMOVABLE STOPS. KEEP THE SCREWS.
4) APPLY 1/8" X 1/2" CLOSED CELL FOAM GLAZING TAPE TO THE FIXED STOP.
5) IF THERE IS PLASTIC RELEASE ON THE FOAM GLAZING TAPE, PULL THE PLASTIC RELEASE BACK ABOUT 2" FROM
EACH END OF THE FOAM TAPE. PULL THE PLASTIC RELEASE ABOVE THE FIXED STOP SO IT CAN BE GRASPED AFTER
PLACING THE POLYCARBONATE ON THE UNEXPOSED FOAM TAPE.
6) IF THERE IS PAPER RELEASE ON THE FOAM GLAZING TAPE, REMOVE THE PAPER RELEASE BEFORE GLAZING. SPRAY
THE EXPOSED FOAM TAPE WITH A MILD SOAP SOLUTION IMMEDIATELY BEFORE PLACING THE POLYCARBONATE.ON THE
EXPOSED FOAM TAPE.
7) PLACE GLAZING SHIMS, AS NEEDED, THEN SET THE POLYCARBONATE ON THE FOAM GLAZING TAPE.
8) ADJUST THE POLYCARBONATE, AS NECESSARY, TO CENTER THE POLYCARBONATE IN THE CUTOUT.
9) IF THE RELEASE IS PLASTIC, GRASP THE FREE END OF THE PLASTIC RELEASE, WHILE HOLDING THE POLYCARBONATE
TO KEEP IT FROM MOVING. THEN SLOWLY PULL THE PLASTIC RELEASE OFF OF THE FOAM TAPE THAT WAS APPLIED TO
THE FIXED STOP.
10) APPLY 1/8" X 1/2" CLOSED CELL FOAM TAPE TO THE REMOVABLE STOP.
11) IF THERE IS A PLASTIC RELEASE ON THE FOAM GLAZING TAPE, PULL THE RELEASE BACK ABOUT 2" FROM EACH
END OF THE FOAM TAPE. PULL THE PLASTIC RELEASE ABOVE THE REMOVABLE STOP SO IT CAN BE GRASPED AFTER
PLACING THE REMOVABLE STOP ON THE POLYCARBONATE.
12) IF THERE IS PAPER RELEASE ON THE FOAM GLAZING TAPE, REMOVE THE PAPER. SPRAY THE EXPOSED FOAM TAPE
WITH A MILD SOAP SOLUTION IMMEDIATELY BEFORE PLACING THE REMOVABLE STOPS AGAINST THE POLYCARBONATE.
13) USING THE ALIGNMENT MARKS, POSmON THE REMOVABLE STOPS AGAINST THE POLYCARBONATE.
14) INSTALL AND TIGHTEN THE TEK SCREWS IN THE REMOVABLE STOPS. BE CAREFUL NOT TO OVER TIGHTEN.
15) IF THE RELEASE IS PLASTIC, GRASP THE FREE END OF THE PLASTIC RELEASE, AND SLOWLY PULL THE PLASTIC
RELEASE OFF THE FOAM TAPE THAT WAS APPLIED TO THE REMOVABLE STOP.
16) USING DOW CORNING 995 SILICONE OR OTHER HIGH QUALITY SILICONE, APPLY A CAP BEAD OVER THE CLOSED
CELL FOAM TAPE ON THE EXTERIOR SIDE OF THE DOOR VISION LIGHT KIT.
(Conversion: 1' = 25.4 mm, e.g., 1-3/4" = 44.45 mm)
C=—CecoDoor
9-125
09/27/17
Page 15of18
Windstorm Door Installation Instructions
M Fok Use With FL 4553
TYPE "C"
l" X i"
Foam Tope
500�
750°
X g`"' Double —
Sided Tape (OPTIONAL)
D0258
625"
f8 X 1 1" Phil. F.H.
TEK Screw
Dow Corning
995 Silicone
zOr'.I.P.,,ekl,
otwelds �" Max.
m End & 8" Max.
Center 3" Mox.�
From End & 12" Max.
On Center
NOTES:
1) Gloss is Glasslam Safety .Plus 11
2) Multiple kits allowed
3) NA Trio/Trio-E or Imperial/Versadoor
.625"
B X 1 }" Phil. F.H.
TEK Screw
Dow Corning
995 Silicone
Spotwelds Max.
From End & 4" Max.
On Center
22"
6"
—�-IMIN
MAX
EXPOSED
GLASS
6" MIN
66"
MAX.
:XPOSEO
GLASS
DESIGN LOAD = +/— 60 PSF
IMPACT RATING = 350 FT LBF
Alternate Flush Welded Glass Kit Details
C=—Cecowor
�� Page 16 of 18
ASSAABLAY
Windstorm Door Installation Instructions
" Fdr Use With FL 4553
Glasslam Safety Plus II Glazing Instructions
TYPE "C" TYPE "D"
F" X J° 625 a' X �' 625'
Foam Tape #g X t )' Phil. F.H. Foam Tape
TEK Screw T X 1 e' Phil. F.H.
TEK Screw
Dow Corning Dow Corning
500, 995 Silicone .625' .500' 995 Silicone
'y1F� Spotwelds `J' Mox. Spotwelds 5A° Max.
.750'J From End & 8° Max. From End & 4° Max.
On Center On Center
j= X 0 Doubt s9aveids 3' Max.
Fv
Sided Tape F.-End & 12' Max.
at Required) G, ante, PET Flcp Required
PET Flop Require
] X 1-4" Oval
Foam Tape d° X) 1875 Head
ad TEK Screw
1 W5'
AiW PET Flap Require
spotveWe 3" Mac
Fmm End & 12" Max.
On ante,
DOW CORNING
995 SNCONE
t
pA NG
G AMisAFEtt' PLUS 2
lAMiNATED CIP55
PET Flap Required lYPE2VIGI0N11GMpF
1) BEFORE REMOVING THE REMOVABLE STOPS, CHECK TO BE SURE THERE ARE SCREWS IN EVERY HOLE. IF A SCREW IS MISSING AND
THE MATERIAL BELOW HASN'T BEEN DRILLED, THEN PRE —DRILL HOLES WITH CORRECT BIT FOR SCREW SIZE. DO NOT REMOVE STOPS.
2) USING A PENCIL, MARK ALIGNMENT MARKS ON THE REMOVABLE STOPS (AND THE DOOR IF TYPE 2 KIT).
3) UNSCREW THE TEK SCREWS FROM THE REMOVABLE STOPS AND REMOVE THE REMOVABLE STOPS. KEEP THE SCREWS.
4) APPLY 1/8' X 1/2' CLOSED CELL FOAM GLAZING TAPE TO THE FIXED STOP.
5) IF THERE IS PLASTIC RELEASE ON THE FOAM GLAZING TAPE, PULL THE PLASTIC RELEASE BACK ABOUT 2" FROM EACH END OF THE
FOAM TAPE. PULL THE PLASTIC RELEASE ABOVE THE FIXED STOP 50 IT CAN BE GRASPED AFTER PLACING THE GLASSLAM ON THE
UNEXPOSED FOAM TAPE.
6) IF THERE IS PAPER RELEASE ON THE FOAM GLAZING TAPE, REMOVE THE PAPER RELEASE BEFORE GLAZING. SPRAY THE EXPOSED
FOAM TAPE WITH A MILD SOAP SOLUTION IMMEDIATELY BEFORE PLACING THE GLASSLAM ON THE EXPOSED FOAM TAPE.
7) PLACE GLAZING SHIMS, AS NEEDED, THEN SET THE GLASSLAM ON THE FOAM GLAZING TAPE.
8) ADJUST THE GLASSLAM, AS NECESSARY, T•0 CENTER THE ASSEMBLY IN THE CUTOUT.
9) IF THE RELEASE IS PLASTIC, GRASP THE FREE END OF THE PLASTIC RELEASE, WHILE HOLDING THE GLASSLAM TO KEEP H FROM
MOVING. THEN SLOWLY PULL THE PLASTIC RELEASE OFF OF THE FOAM TAPE THAT WAS APPLIED TO THE FIXED STOP.
10) TRIM THE PET FLAP SO IT DOES NOT EXTEND BEYOND THE REMOVABLE GLASS STOP.
I I) TAKE A PUTT KNIFE AND INSERT IT BEWEEN THE PET FLAP AND THE EDGE OF THE CUTOUT IN THE DOOR. USING THE PUTTY
KNIFE PULL THE PET FLAP AWAY FROM THE CUFOUF IN THE DOOR.
12) WHILE HOLDING THE PET FLAP BACK AWAY FROM THE CUTOUT WITH THE PUFF! KNIFE, USE A CAULKING GUN TO APPLY DOW
CORNING 995 SILICONE BETWEEN THE PET FLAP AND THE STEEL IN THE CUTOUT OF THE DOOR.
IMPORTANT' ENSURE THAT THE DOW CORNING 995 SILICONE FULLY WETS OUT OR COVERS THE PET FLAP AND COMES
IN CONTACT WITH THE STEEL AROUND THE CUTOUT IN THE DOOR.
13) SLOWLY MOVE THE PUTTY KNIFE AROUND THE DOOR AHEAD OF THE CAULKING GUN AND APPLY THE 995 SILICONE AROUND THE
ENTIRE CUTOUT IN THE DOOR.
14) APPLY 1/8' X 1/2" CLOSED CELL FOAM GLAZING TAPE TO THE REMOVABLE STOP.
15) IF THERE IS A PLASTIC RELEASE, ON THE FOAM GLAZING TAPE, PULL THE PLASTIC RELEASE BACK ABOUT 2" FROM EACH END OF
THE FOAM TAPE. PULL THE PLASTIC RELEASE ABOVE THE REMOVABLE STOP SO IT CAN BE GRASPED AFTER PLACING THE REMOVABLE
STOP ON THE GLASSLAM.
16) IF THERE IS PAPER RELEASE ON THE FOAM GLAZING TAPE, REMOVE THE PAPER. SPRAY THE EXPOSED FOAM TAPE WITH A MILD
SOAP SOLUTION IMMEDIATELY BEFORE PLACING THE REMOVABLE STOPS AGAINST THE GLASSLAM.
17) USING THE ALIGNMENT MARKS, POSITION THE REMOVABLE STOPS AGAINST THE GLASSLAM.
15) INSTALL AND TIGHTEN THE TEK SCREWS IN THE REMOVABLE STOPS. BE CAREFUL NOT TO OVER TIGHTEN.
19) IF THE RELEASE IS PLASTIC, GRASP THE FREE END OF THE PLASTIC RELEASE, AND SLOWLY PULL THE PLASTIC RELEASE OFF THE
FOAM TAPE THAT WAS APPLIED TO THE REMOVABLE STOP.
20) USING THE DOW CORNING 995 SILICONE OR OTHER HIGH QUALITY SILICONE, APPLY A CAP BEAD OVER THE CLOSED CELL FOAM
TAPE ON THE EXTERIOR SIDE OF THE DOOR VISION LRE KIT. 9-126
(Comercon: I` = 25.4 mm, e.g., 1-3/4' = 44.45 mm) 09/27/17
MecoDoor
Page 17 of 18
ASSAABL0Y
Windstorm Door Installation Instructions
y For Use With FL 4553
SECURITY
GRILLE
LOUVER INSTALLATION
NOTES+
1. DESIGN PRESSURE - 70 PSF MAX. (OUTSWING ONLY).
2. MARKAR WLV60 LOUVER WITH SECURITY GRILLE SHOWN.
3. ANY LISTED LOUVER MAY BE USED.
4. MAXIMUM LOUVER SIZE IS 34' X 7B'.
5. 6' MINIMUM STILES AND RAILS.
6. MULTIPLE LOUVERS ALLOWED PER DOOR
7. NOT AVAILABLE WITH TRIO OR TRIO-E
INTERIOR Isss,
.w
\ OPTIONAL END CHANNEL
/ SURROUND PROFILES
Ib56'
18
425'
LSW
L
GA. MIN.
URROUN➢ CHANNEL
Louver Details
Meco 000r
D0274