HomeMy WebLinkAboutPLANSConnector Schedule
Truss
Bearing
Truss
Connector
Qnty'
Connector
Fasteners
Point
Uplift
ID
Uplift
A05G
2
2199
DETAL2
2
2480
(9) lOd x 1 1/2"
7
2237
per Strap
All Other
Trusses
ALL
<1810
HETA20
1
1810
(9) 10d x 1 1/2"
to C.B.S.
Valley
Supporting
Framing
(4) lOd
Trusses
<250#
VTCR
1
370
Valley
Rafter
(3) 10d x 1 1/2"
Connector Notes:
Do not substitute connectors
Do not sheath trusses before all straps are in place
Lateral forces perpendicular and parallel to wall has been
considered (less than 300 p.l.f.)
Contractor to approve temporary bracing to prevent toppling
of trusses.
14'-0"
New Addition
East Elevation
scale: 1/4" =1'-0"
Stucco Finish and
Cola to Match the
Existing Residence
Existing
Residence
Open
F.F.]
South Elevation
scale: 1/4" = 1'-0"
Safe Load Table Notes
1. All values based on minimum 4" nominal bearing.
Exception: Safe loads for unfilled U lintels must
be reduced by 20% if bearing length is less than
6 1/2".
2. N.R. = Not Rated
3. Safe loads are superimposed allowable loads.
4. One #7 rebar may be substituted for two #5
rebar in 8 inch U lintels only.
5. All safe loads in units of pounds per linier foot.
6. All safe loads are based on sunply supported span.
7. Safe load ratings based on rational design analysis
per ACI 318 and AC1530.
quaoiry of k5 reber
t boaom of lintel
r
F—filledgrout aviry
t
s wietn� I
� E .IY
z 8F16-1B/1T
�95 ab"atboaom o ioal� rebar attop.flittelwviry heigth
Lintel Type Designation
Cast Crete Lintel Schedule
Installation Notes
1. Installation of U lintels must comply with architectural
and/or structural drawings.
2. U lintels can be field cut to the required length_
3. Cast in place concrete may be provided in composite
U lintel in lieu of concrete masonry units.
4. The exterior surface of U lintels installed in exterior
concrete masonry walls shall have a coating of stucco
applied in accordance with ASTM C-926 or other
approved coating.
5. Concrete masonry units used in composite U lintel shall
be laid in a running bond.
6_ Shore composite lintels as required.
7. U lintels are manufactured with a 5 1/2" long notch at
both ends to accomodate vertical cell reinforcing and
grout.
Composite U Lintel Materials
1. Grout per ASTM C476 fg=3000 psi with maximum 3/8
inch aggregate and 8 to 11 inch slump.
2. Rebar per ASTM A615 Grade 60
3. Concrete masonry units (CMU) per ASTM C90 with
minimum net area compressive strength = 1900 psi
4. Mortar per ASTM C270Type M or S
All Rebar to be #5 Grade 60 min.
MARK
LENGTH OF
ALLOWABLE
APPLIED
ALLOWABLE
APPLIED
BEAM SPECS.
LINTEL
GRAVITY LOAD
GRAVITY LOAD
UPLIFT LOAD
UPLIFT LOAD
L-1
13'-4"
1075
567
770
574
8F16-1B/2T
112
24'-0"
450
160
316
136
8F16-1 B/2T
B.
Min. Beam depths shown, beams may be increased without comment
At Lintel L-2 provide (1) #3 vertical rebar
at 24"o.c. along length of lintel
West Elevation
scale: 1/4" = 1'-0"
59.45'
t
I
I
i 1.4.7' r-
Proposed
Covered
Porch
Existing
Residence
I
I
tl
1
I
Conc.
Patio
I
I�
W
0
O
t
I
I
I
t
Partial Site Plan
scale: 1" = 20'
14'-0"
New Addition
Flame Spread Index & Smoke Developed Index
Insulation Flame Spread: Not to exceed 25
Insulation Smoke Developed Index: Not to exceed 450
Wall Finishes: Not greater than 200
Ceiling Finishes: Not greater than 200
Climatic & Geographic Design Criteria
Weathering: Negligible Termite Area: Very Heavy
Electrical Notes
1. All loads to be checked by aFlorida Licensed Electrician
2. All work to meet the National Electrical Code
3. All conductors to be copper; all insulation to be THHN. Conduit as
follows: PVC below ground, Rigid from underground to service box
for exterior lights on building; AC, MC, or EMT conduit elsewhere.
4. Ensure min. 36" clear between equipment and disconnects, Typical.
5, Existing Electrical Panel to Remain
Electrical contractor to verify all equipment loads prior to
start of construction. Electrical contractor to recalculate
electrical schedule if loads are to be modified
See Masonry to
Masonry Connect.
Buildinl? Code
2017 Florida Building Code: Residential
2017 Florida Building Code: Existing Buildings
Alteration Level II
2014 National Electric Code
Scope of Work
New Rear Porch Addition
ELECTRICAL LEDGEND
"1 6" LED RECESSED Ln: RT
C
DUPLEX OUTLET -W SWITCH
ALL 120V SINGLE PHASE 15 & 20 AMP BRANCH CIRCUITS SUPPLYING
OUTLETS THAT ARE NOT GFCI MUST BE AFCI.
TAMPER PROOF RECEPTICALES MUST BE INSTALLED IN 120 VOLT, SINGLE
PHASE 15 & 20 AMP BRANCH CIRCUITS
.....................................�.::,
4'_2"
..........,
Partial Existing Floor Plan
scale: 1/4" = F-0"
Design Loads
Roof Live Load: 40.0 p.S.f.
Wind Speed: 160 MPH
Wind Importance Factor: 1.0
Building Category: II
Wind Exposure: C
Internal Pressure Coefficent .18
Structure Designed: Enclosed
Soil bearing capacity: 2000 p.s.f.
Area Tabulation
355 square feet
Project Data
Project Name: Jason Baskerville
Street Address: 8400 Cobblestone Drive
City: Ft. Pierce
County: St. Lucie
State: Florida
24'-6"
................ ................................................. .........................
I...,
25-4" New Addition
4" 22'_8" P-4
SEE FOUNDATION PLAN FOR
CONCRETE PATIO LOCATION
............................................... L-2...........................................
I
I
I
Line of the Existing
t Porch to be Removed t
L-1 I .------------
..
I
I I I
I
I I I I New Porch
I t I t
I
\ I 8'-8" Ceiling
from F.F.E.
s"x
I \ I
Existing
I
I
I
I
I
I
I '
I
I L-1
I
I
13'-4"
See Masonry to
Masonry Connect.
EXISTING-' RESIDENCE
0
N
Partial New Floor Plan
scale: 1/4" = 1'-0" WITH NEW ELECTRICAL
r
t—I
7t
�
M
�
w
z
t�b
a
t
��
a
t/1
z
b
y
Q
O
Con
4
U
o
1F�1
M:
Q
v I
r-
O
r1
ct
cC
7t
c
O
cG
00
U��
rN
ct
f4
oo
M
FBI
�
Q
Lon
x
�
o
U
U
_U
0
44
REVIEWED
FOR
CODE
COMPLIANCE
ST. LUCIE COUNTY
date revision
SCANNED
�Y
St. Lucie County
drawn
a).
checked
0.
date.
3/3/19
scale
as noted
job number
19024
sheet 1
A— 1
Flit f--410py
1103 - C* 32..
C
C
cc
C
STRUCTURAL NOTES:
All reinforcing steel shall be high strength billet steel and shall
conform to ASTM A-615 grade 60 specifications. Lap continuous
reinforcing 48 bar diameters or 30" in beams and in slabs. Lap
bottom steel over supports and top steel at midspan. Hook
discontinuous ends of all top bars. Reinforcing steel shall have
a minimum of 1" concrete cover, or as follows:
BOTTOM TOP SIDES
Beams: 11/2" 11/2" 11/2"
Slab on Grade: 1 1/2" 1" —
Structural Poured: 3/4" 3/4"
Poured Walls: 3/4"
Slabs exposed
to the weather 3/4" 1"
Reinforcing steel shall be detailed and fabricated in accordance
with the "Manual of Standard Practice of Detailing Reinforcing
Concrete Structures" and the current "ACI Building Code 318"
All structural steel shall conform to current ASTM Specification A-36
All wood in contact with masonry shall be pressure treated or approved
seperating material.
All dimensions shall be verified in field by the contractor. If there are
any discrepancies the Architect or Engineer shall be notified before
proceeding.
No slump over 5" shall be permitted for any structural concrete without
the Architect or Engineer approval.
All Design and Construction shall be inaccordance with the current
American Concrete Institute (ACI). and the American Institute of Steel
Construction (AISC), The Florida Building Code and all applicable
local codes.
Structural Concrete shall attain a minimum ultimate compressive strength
(Fe') in 28 days as follows:
Column Footing and Wall Footing: 3000 p.s.i.
Column and walls from foundation to roof: see column schedule.
All other concrete: 3000 p.s.i.
Footing sizes and reinforcing are based on allowable soil bearing
capacity of 2000 p.s.i. All footings shall bear in virgin soil. If this
is not the case, the Architect or Engineer shall be notified before
proceeding with the work.
Timber (Heavy Timber Construction)
(a) Truss manufacturer shall submit a signed and sealed shop
drawings by a registered Engineer.
(b) Wood rafters to have a Stress Grade of Fb-1200 p.s.i.
(c) Roof members should be secured to the beams or other
structural components with hurricane anchors for wind uplift.
All wood members shall have a minimum fiber stress in bending
of 1200 p.s.i. with 1/360 max. deflection.
All bolted connections shall be 1/2" Cadmium plated or better.
Lag bolts to be used only in shear connections with minimum
4" threaded penetration past steel plate.
Lag bolted conditions shall be drill tapped no larger than the
internal thread diameter and shall not be hammer driven.
GENERAL REQUIREMENTS
All work to be as per the current edition of the Florida Building Code
and meet or exceed all applicable local requirements.
General contractor is responsible for all labor, materials, utilities, testing,
waste removal, storage, securing of site, accomodation, transporUfteight,
and all other cost related to the completion of this project., unless explicitly
identified here.
Owner is responsible for all municipal related charges such as impact
fees, and water connection, except building permit fees, which are to be
included in the construction bid.
General contractor to check all drawings for errors and ommissions and
bring them to the attention of the architect prior to starting any work, or
ordering any materials of the respective division of work. If such errors
and ommissions are not reported in writingto the architect, any resulting
damages or costs shall be born entirely by the general contractor.
Architect is not responsible for the contractors method or means of
construction.
General contractor is to keep the site in a clean and safe state through
out the course of construction. On building turnover, general contractor to
clean all surfaces so as to be free of dust, grease, stains, scuffs, etc.
Unless otherwise noted, the installation of specified hardware shall
conform to the manufacturers instructions and standard practice.
All plans and drawings are not considered complete until they have been
reviewed and approved by the St. Lucie County Building Department
and the building permit has been issued.
EXTERIOR CEILING NOTE
7/8" Stucco finish over 3/8" high ribbed gals. wire lath fastened to
framing members with No. 11 guage nails with 1 3/4" embed. with 3/8"
dia. head 6"o.c. max. edges to be tied and nailed at 9"o.c.
Install one layer of 15# felt to framing prior to installing ribbed lath
corner bars at beam
(outside only) (2) comer
bars at footing (min.) —
vert. dowel lapped with 1t
wall reinforcing, all 11 all comer bars to be the
laps 25" (min.) in grout I1 same size, number, and
filled cell 1) spacing as horizontial bars
1) in footing, beams, and walls
11
(1
1
GENERAL ROOFING NOTES
Roofing to be composed of and attached to pre manufactured
wood trusses as follows:
Felt underlayment (min. ASTM 0 226 Type II) with 4" min. side and
end laps, fasten with coorosion resistant annular ring shank nails
at 6"o.c. in laps and in staggered rows spaced 12"o.c. in field.
If roof pitch is < 4/12 install (2) layers 15# felt.
If roof pitch is 4/12 or greater, install (1) layer 30# felt.
5/8" cAx. sheathing or equal installed with staggeredjoints & GI clips,
nailed to trusses with 8d corrosion resistant annular ring shank nails
spaced max. 6"o.c. throughout, except max. 4"o.c. at gable ends.
All roof trusses are to be pre -manufactured assemblies provided by
a licensed wood truss fabricator with seperate drawings and data
prepared for actual project conditions by a Florida registered
professional engineer certified for muss design. Any deviation from
the proposed plans as shown regarding placement or bearing shall
be brought to the attention of the truss engineer prior to fabrication
of the trusses. The truss manufacturer's certified layout shall govern
after fabrication.
The handling, erection, and fixing of wood trusses shall be in
accordance with the specifications contained on the certified mfgfs.
drawings and data.
All engineered headers and truss hangers to be provided by the
truss manufacturer.
Splitting or cracking of structural components due to installation of
hardware is not permitted.
Unless otherwise noted, the installation of specified hardware shall
conform to the truss manufacturers installation instructions and
standard practice.
SHEATHING NAILING NOTES
Nailing Pattern
Zone 1: 8d at 6"o.c. field & 4"o.c. edges
Zone 2: 8d at 4"o.c. edges & field
Zone 3: 8d at 4"o.c. edges & field
Pneumatic Nails
Pneumatic or mechanicaly driven nails will
be accepted under the following conditions:
Min. nails size 8d or larger ring shank with
Min. shank diameter:.113
Min. Length: 2"
Min. Head Diameter:.280 Full Round
Min. Ring Diameter .012 over shank dia.
Min. 16 to 20 Rings per Inch
Note
Gun nails shall be permitted as an
acceptable fastener from any manufacturer
Wood screws meeting the same size requirement
may be used in lieu of nails without comment
Nailing Schedule
ROOF DIAGRAM
Use sheathing with #8 gun nails at 6"o.c.
at supported panel edges and #8 gun
nails at 6"o.c. at intermediate supports.
12"
Panel
Each Nail hem fasten with
Staples with 1" Long
Legs & 16 Ga. dia.7'o.c. -
soffit panel
F channel fasten with
Stub Nail
.097 dia. & 5/8" Long
24"o.c.
drill & epoxy steel in
perimeter beam 5" into
existing masonry
8" C.M.U. W
drill & epoxy #5
rebm-, 5" into new
& existing solid pour
cell at 24"c.c. max.
8" x 8" FILLED
CELL
MASONRY TO MASONRY CONNECTION
CONTRACTOR TO VERIFY
ROOF PITCH, HEEL HGHT.
AND OVERHANG LENGTH.
EXTERIOR FINISHES AND
MATERIALS TO BE VERIFIED
BY THE CONTRACTOR TH
12
AT
THEY MATCH THE EXISTING Q 6
RESIDENCE
Soffit Detail-
4
ri
13 3
TT_O.B_—
Verify with
Existing
Stucco
Ceiling
Lintle br Bond Beam
with (1) #5 Rebar
in each course, Filled
with Grout
#5 vert. rebar in
grout filled cell
See Floor Plan
for Locations
4" 3000# Fibermix Cone.
on .006 Vapor Bearier on
Clean, Compacted, Termite
Treated Fill
0.00'l - F.F.E. - —
v
v
(2) #5
Rebar
1'-6"
Fiberglass Shingle Roofing on
One Layer of 30# Felt on
19/32" c.d.x. plywood fastened
as per nailing schedule
Pre Engineered Wood
Roof Trusses 24"o.c.
Shop Drawings by
Others
See Connector
Schedule
12"
Alum. Drip
Edge
2 x 6 Fascia with
Alum. Wrap
Vinyl Vented
Soffit
2 x 4 P.T. cont.
8x16x8
CMU Typ.
Stucco Finish
to match the
Existing
i #5 Vert. Rebar with
10" Hook and 30"
Lap. Tie to Vert.
Rebar In Cells
N
Corner Reinforcing Detail Roof Wind Zones Typical Section
Grade
0
v
.2
�a
y
z
0
-
FORMWORK & SHORING
No structural concrete shall be stripped until it has reached at least 80% of
the 28 day design strength.
Design, Erection, & Removal of all formwork, shores, & reshores shall meet
meet the ACI Standards 347 and 301
Contractor to verify all building setbacks prior to the start of construction.
A formboard survey shall be submitted to the building department for
approval prior to pouring concrete.
SOIL STATEMENT:
Foundation has been designed for a soil bearing capacity of 2000 p.s.i.
Fill shall be laid in layers of 6". Each layer to be compacted to 95%
compaction.
If the contractor encounters, while digging the foundation, any
discrepancy to suggest the soil may be inadecuate, he must
immediately report it to the owner and the Architect or Engineer
so as to order a soil boring test.
Dowel Rock Repair Note
In the event vertical steel has been omitted from the down
pour locations, drill 5" into concrete (no closer than 3 3/4"
from edges and 5" from ends of cap walls) Remove dust
per manufacturers instructions and use Two part epoxy to
anchor the #5 rebut in place. Use either "Hill C-100" or
Simpson Epoxy -Tic.
GENERAL FOUNDATION NOTES
Concrete shall be a minimum of 4" thick over clean, compacted,
termite treated fill and 6 mil polyethylene vapor barrier.
If concrete slab contains 6" x 6" 10/10 W WM provide 1" coverage
Concrete shall have at minimum compressive strength of not less
than 3,000 p.s.i.
All 90% hooks are to be extended 10" minimum beyond the turn.
Field bends are to be done cold and the diameter of the bend,
measured on the inside of the bar, is not to be less than six
bar diameters.
Minimum coverage for rebar shall be 3" in footings and 1 1/2" in
bond beams. Hooks may be rotated horizonitally if required to
achieve minimum coverages.
Rebar overlap shall be 48 bar diameters. 30" for #5 rebar
The foundation design assumes that the soil has a minimum
load carrying capacity of 2000 p.s.f.
In the event the soil bearing capacity falls below 2000 p.s.f. This
foundation plan may be superseded by Foundation Design Engineer.
Satisfactory compaction test of fill does not verify lower soils are
adequate.
All specifications and dimensions to be verified by contractor.
All exterior slabs shall slope a minimum 1/8" per foot for drainage
F-I
F-2
F-3
F-4
18" x 16" mono. footing18"
x 16" mono. footing
g
8" x 8" mono. footing
with (1) #5 rebar cont.
10" x 10" mono. footing
with (1) #5 rebar cont.
with (2) 45 rebar cont.
with (2) #5 rebar Cont.
4"
16„
_L 10
4
8,,Jr":IT181,s"
4"
MONO. EDGE FOOTING
INTERIOR FOOTING
THICKENED EDGE
THICKENED EDGE
'_4„
25'4" New Addition
22'-8"
l'-4
10'-0"
13'-4"
F-4
F-4
I
I
I
v
�---- ---------- ------------
�F-2,
O
F------------------------------1
I I
i
i I
I I
I I
I I I
I I
0I4
Line of the Existing I I
Porch to be Removed I
I
I
4
I I I I F-2 I
1
4" 3000# FIBERMIX CO.NC,
1
F-1 I I I 1
OVER.006 VISQUINE
I I I I I
ON CLEAN, COMPACTED, I
I
TERMITE TREATED FILL
I I I
I I I I I
I I I 4 I
I
L-- — — — — — F-3------I------------J
I I
----- F-3 ----J
I LN
li
uuu
u u u
EXISTING RESIDENCE
0.00'
FEE
ASSUMED
Foundation & Footing Plan
scale: 1/4" = P-0"
u U
PRODUCT APPROVAL
Approval
Number
Product
Model Number
Manufacturer
Attachment Method
Building Rated
Design Pressures
Product Rated
Design Pressures
NOA: 15-1215.11
Roofing
Asphalt Shingles
TAMKO
(6) 1 1/4" Roofing Nail per Shingle
FL#: 13389.1
Soffit
Vinyl Vented
CertainTeed
See Soffit Detail
+35.0 -35.0
+246 -76
00
00
M-1
0�\
�
M
�
w
,U
t�
r�
V)
a
r_
Q
o
.,�
U
w
�
Z
cn
C�l
�
a
i
40
�r'
C/1
}�
W
I-1
Q
�
O
ct
ct
ct
cr1
0000
C
Ct
00
Q
M
Q
O
i/]
>.
H
Q
o
7�
w
p
z
°
N
x
�
O
�
N
U
v
O
tX
0
W
C4
drawn
s.l.
checked
s.l.
date
3/3/19
scale
as noted
job number
19024
sheet
A-2
•BUILDER"S WARNING*
COMPONENTS AS DEFINED BY WTCA i -1995.
1) FOR THE ERECTION BRACING FOLLOW INSTRUCTINS
STRUCTURAL DATA, NUMBER OF GIRDER AND
DESIGN DEPARTMENT APPROVES THEM IN ADVANCE
BEARING POINTS MUST BE INSTALLED
DIAPHRAMS HAVE ANALYZED BY
BCSI-BI G SUMMARY
2)PERMANENT
ERB ME
ERIOR
FAST OAST TRUSS.TBEEN
BRAHE
ORETHES RUCNRE IS ME
PLIES AND THE CONNECTION INFORMATION.
OTHERW SE NOTEOSIN TALL HANGERS ACCORDING
TO INSTALLING ANY TRUSSES!
ERECTION AND INSTALLATION OF
OF OTHERS.
UP DESIGN RMUST VE
O THE CURRENTSIMPSON STRONG TIE CATALOG
FAILURE
FOR
LLOW INSTRUCTIONS ON THE BCSI-BiRUSSES SUMMARY
3) IINNSSTALL B BRACING AS STATED ON SEALED
REPAIRS TO TRUENT
AND/OLITY
SSES IN
,DDITION NOTE:
IS THE BUILDERS RESPONSIBILITY TO
ERIFY ALL EXISTING CONDITIONS, ECT
ANNOT BE RESPONSIBLE FOR MATCHING
XISTING ROOF CONDITIONS.
PON SIGNING, BUILDER AGREES TO ALL
ONDITIONS AS SHOWN ON THIS LAYOUT
EXISTING:
VERIFY ALL CONDITIONS,
PITCH, HEEL & DIMENSIONS
TRUSS PLACEMENT PLAN
8'-8" T.O.B.
\=S2^
8'-8" T.O.B. EXISTING
==^
vi�
10. TYP. END
�' DETAIL
12
6r
EAST COAST TRUSS
521i5 St. LUC¢ BLVD. IT. PIERCE FL 349646
OFFICE (772) .166-2480 FAX f77Dffi6-5336
USTOMER:Telese Builders
DB NAME:COBBLESTONE 8400
DDRESS:8400 COBBLESTONE DR
Kr: '.
w
ODEL Addition
F
ARAGE
OFT 526
Q
g
ATE 2/1/19
EAST COAST TRUSS I. the
amen eear
d I. mo maodece wiM me
emlame cone
Ironing this placement plan(s), signs mred anywhere on this sheet, the
Sir or his represenlitive acknowledges that this placement plan comple,
e structural Intent of the project.
customer also admoWledges that this approval authoMes FAST
T TRUSS to manufacture these trusses and deliver them to the project
act on this drawing.
customer also acknowledges that he/she accepts financial
sioilily for any repair, engineering, and labor required due to errors
nan those of EAST COAST TRUSS.
ned:
DE=FBC2017/TPI 2014 ASCE 7-1
SIGN CRITERIA =MWFRS
CUPANCY CATEGORY =11
POSURE=C
JF SPEED =160
ILDING TYPE =PARTIALLY
HEIGHT = 15'
GRAVITY LOADS
DUR FACTOR= 1.0
TCDL- BCLL-BCDL
DUR FACTOR= 1.25
- TCDL - BCLL - BCDL
'NON -CONCURRENT BC U. 1OPsl
UNLESS SHOWN ON ENGINEERED TRUSS
DRAWING.
ALL GIRDER/COLUMN LOADS MUST
BY-PASS FLOOR TRUSS UNLESS SHOWN
ON ENGINEERED TRUSS DRAWING.
FLOOR TRUSSES SPANNING 20'-0" OR MORE
MOULD BE AT LEAST 12 TO
$ THE SPAN OF THE TRUSS
BEING SET.
REFER TO BCI-81 FOR COMPLETE
ERECTION AND SAFETY PROCEDURES.
SHELVES
A
1
1
1
1
1
1
I
1
I
1
1
1
1
1
I
1
1