Loading...
HomeMy WebLinkAboutCERTIFICATION FOR DESIGN LOAD COMPLIANCE`�" -' "�' = "` Planning & Development Services Department Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 - (772) 462-1553 SCANNED Certification for Design Load Compliance BY �/I /l St. Lucie County Project Name: /"Iar5t'cl1 9I5Tricncc Nwn�or' Project Address: sw (Jn ton tl - 64 95 6 rrcgsvrc Coast A'r�c 1c Permit #: Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: This certification must be completed, signed, and sealed by the design professional of record. Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 5iX4k 1. DESIGN CODE: Florida �$..;11;,.� Code FiffH Edition with 20 1'_Supplements using ASCE 7-10 2. Structure Designed as (check one): >C Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B ) _C _D 4. Design Wind Velocity / G 0 mph _ASD X LRFD End Zone Width: N. 8 ft S. Mean Roof Height 2 f' 0 ft Roof Pitch: c/ :12 Parapet: N A ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone1: 3g.1 Zone2: NN.L Zone3: `1N•6 Zone4: Nr•3 Zone5: F;. Garage: Per S,j.«f 7. Design Loads: Floor: !u A PSF Roof/Dead: OMS PSF Roof/Live: 96 Balcony: N/A PSF 60A. Dock: N 1A PSF Deck: NIA PSF Stairs: [VIA PSF Fence: AI A PSF Railings: f4 1A PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: rtr 51-ecl $-:12?nN Eo(C - zsc�^ 5�((.(h�rld: ,s 9. Is A Continuous Load Path Provided? X Yes Not Applicable Explain Why Not: Pr, S�rcl �Fok - d« Sl�cl AmJJ,n,s 10. Design Soil Bearing Pressure: Z Soo PSF Soil Test Reports Submitted? X Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces specified: Print Name Cert # & Co. Cert Auth. 47 Q—, T'oM Eily; nctr,ng Ass acic,�i-cJ+ c- e1 3uo A., - o r r 53-4, ZLo Signature, Da , and Seal ekl. gcacl,' G�.di„s, FL 33.11 8' Company Name & Address Revised 07/25/2014