HomeMy WebLinkAboutMOBILE HOME ROOF OVER PLAN'• .024ALUMROOF
' ALUM
2 WDGFDPGLYGLYRENE OLSULATION
2' RIDGED PDLYSTYRI' _ ItATION
E70STINGMOBDE HOME ROOF
7
/
PLUM. ATTACH RAIL
wi#8X11145NS.3 O.C.
�BUMRUBBERSEAL
EXISTING PAPO ROOF
7
V'7>•\ /
wI18X1114SA1.S. 3' O.C.
D24ALUMROOF
2X3P.TWfflW'W.S.QB'0.�
rINSULATION
2X3 P.T. BLOCKS CUT TO FIT 0
PANS wI(2) 98 SMS. PER PAN
ALTERNATE COACH & PATIO ROOF ATTACHMENT #1 ALTERNATE PATIO PAN
CONNECTION DETAIL KITS) (NO 401 WALL) N.T.S.
.024 ALUM
wl#8X1 U4 SMS S'O.C.
ALUM ROOF FLASHING
EXTRUDED ALUM. ATTACH RAIL
wll81(11M$M.S.TO.C.
ALUM ROOF
2X3 P.T. BLOCKS CUTTO FIT If
PANS w/ (2) #S S7LS. PER PAN
EXISTING COACH �'// I T� ALUX INSERTS
FRAME - II\_ _ .
ALTERNATE COACH & PATIO ROOF ATTACHMENT #2
CONNECTION DETAIL(NTS) (w/4th WALL) "
T RIDGED
FRAME
W#BXI U4 SMS. T O.C.
rBUMRUBBER SEAL
r.D24 ALUM ROOF
MAX SPAN 14
MINSULATIONASREQUIRED
ALTERNATE COACH & PATIO ROOF ATTACHMENT #3
CONNECTION DETAIL(NTS) (NO DROP BETWEEN ROOFS) DOUBLE WIDE RIDGE DETAIL
USING ALTERNATE #1 ATTACHMENT (NTS)
MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH E)
wilBX1114SMS.3'O.C.
ANDCAULKORCONRNUE
RASHNGTOGUTIER
OVERHANG
COL. '&amm NSERTEACHPAN
ATTACHMENT DETAIL "A"
A24 ALUM ROOF w1taxi 1145MS.3.0.a
c
3µFELTON TOP OF
BUM RUBBERSE4L
��
A24ALUM FIlSHINGINTO PAN
AND CAUIXORCONIIMIE
FLASHING TO GUTIEft
2X3
SMSdNEOPRFNE
Rm
EACH PAN
EXISTING PANS W
INSULATION INSERTS
DO P.T. BLOM CUT TO FIT
PANS w/(2) 98SM.S. PER PAN
ALTERNATE PATIO PAN
2 RIDGED POLYSTYRENE INSU
OVERLAPPING -
.024ALUMROOF
OVERHANG
COLABFAM INSERTEACHPAN
ATTACHMENT DETAIL "B"
wINXI iM S.M.S. 3' O.C.
�230 P.T.wlIM
WS@?O.C.
FILLER
COOUBLE'WIDE'R1DGE'DETAIL--)
N.T.S.
,
BUTYLRUBBERSI
2' RIDGED POLYSTYRENE INSULATION
OVERLAPPING
A24ALUMROOF\
GUTTER EDGE DETAIL
.024 ALUM
EXSDNGCOACH
FRAME
UMROOFCONT.OVER
. WIFACTORYSEAMSOWO.0
INSULATION
E10STING 1
MOB:EHOMEROOF SINGLE WIDE(NTS)
'UNPICAL OOF_S C OITEC OITE N:j
N.T.S.
#®OM' STANLESS STEEL HD(HEAD
FROM AT TACHMENT RAIL TO EXISTING
MOBILE ROME FRAME® 5- O.C. MIN.
NTOEXISTINGFRWNG ,
UDEUll
4S tS.3TTACH RAIL
wl B8X111/ SM.5.3' O.C.
/--BUTYLRUBBERSEAL
`024 ALUM GUTTER
.W/STRAPS@"O.C.
GUTTER EDGE DETAIL
N.T.S.
T RIDDED POLYSTYRENE INSULATION
E GRUOEDALUM.ATFACH RAIL
W #W%&M.S.3' O.C.
P.T. WOOD BLOCKw(
9W WS. ® SPANNING
TO STRAIGHTEN WOOD ONLY
A24ROLLALUMINUM
INSULATION
ATTACH CONTI. 2Y4' P.T. TO EXISTING
MOBILE HOME FRAMING W/ W WOOD
MUM® SPACING TO STRAIGHTEN
WOOD ONLY, IN LIEU OF FULL FRAMING
ATTACHMENT PER DETAILS
Ik,7,N( FIF1TJ:5H�7`6T�79
ROOF
PATIO ROOF
i0/
m
�,m
•
1
RMLvd#W-1/4 STAINLESS STEEL
SCREWS®SS O.0 INTO
COSTING MOBILE HOME
PRE4UNCIED HOLES.
FRAMING&ROORNG
ALTERNATE ATTACHMENT
RAIL FASTENING #1
N.T.S.
—1
024 GALVALUME CLEAT
48- O.C. OW)
MAR 2 6 2019.
ST. Lucie County, Permittini
ALUM.ATTACHRAIL
SM5.3'O.0
024ALUMFASM
,ATAIIUCENTPATIO ROOF
PROVIDE.024RASHING
INrOPATIOR0OF(MNA')
wl98 SMS@IT O.C.
FRAME
FASCIA EDGE_DETAII
N.T.S.
OWNER:
ADDRESS: \C\l MNL1=
CITY: rT P STA
LOT# LOC
C -
FACTORY SEAM DESIGN FOR RUB ERSEALANT E
ALUMINUM ROOF COVERINGS? —BETWEEN SHEET 6 CLEAT
OVER SOLID ROOFS ONLti PRODUCT APPROVAL #FL5739-R4
OVER ATTACHED STRUCTURES PRODUCT APPROVAL#FL17570-RO
N.T.S.
NOTES:
1.) THIS DESIGN CONFORMS TOTHE:2017 FCORIDA BUILDING CODE FORAa
�CATEGORY IT BUILDING FOR WIND LOADING OF 185MPH, EXPOSURE-.0 AS
LDETERMINED BY ASCE STANDARD 7.
2.) THIS DESIGN CONFORMS-T0 FLORIDA STATUTE 15C-20081 FOR
MOBILEIMANUFACTURED HOME REPAIRAND REMODELING.
'EL 3.) ALUMINUM ROOFING IS DESIGNED FOR USE OVER A SOLID ROOF ONLY. IT
SHALL NOT BE USED AS A STRUCTURAL ROOF SYSTEM.
4.) THE ROOF COVERING SHALL NOT OVERHANG THE EXISTING ROOF.
5.) ENGINEER IS NOT RESPONSIBLE FOR STRUCTURAL INTEGRITY OF EXISTING
ROOF. THE STRUCTURE OF THE EXISTING ROOF SHOULD BE ABLE TO
SUPPORT THE CONSTRUCTION LOADING FOR THE NEW ROOF SYSTEM. -
B.) MAXIMUM WIDTH OF A SINGLE WIDE MOBILE HOME NOT TO EXCEED I4.0.
7.) MAXIMUM WIDTH OF A DOUBLE WIDE MOBILE HOME NOT TO EXCEED W-O
B.) INSULATION TO BE POLYSTYRENE FORM APROX. DENSITY I#PER S.F.
9.) MAXIMUM HEIGHT OF MOBILE HOME NOT TO EXCEED 15-Ar.
10.) MINIMUM THICKNESS OF ALL ROOF FLASHING TO BE .024 ALUM
11.) THE R-VALUE OF THE 2' EPS INSULATION IS R�.7. SHEET No.: 51 01 2.
p Lp NOT VALID UNLESS DATED
S SEALED WITH EMBOSSED
(T-zvsv, L-(J NEER'SSEAL / TESL ) /"tY (�
K# RANGE,:: /7 ES BUS HOUSE. P.E. !!
STATE OFIONAL FLORIDAGINEER 20311
0
C3
P
qq g
O�0
4 VQ
1.q0
-4
w
Z�Co
02
m
Co
Gq
CEO
O
t t, 4
'+ C,2
o
N
N p�pO
r� ao r
^Y Uqm
�r FV�
7 . 'C
O24
�2o,b
cl i
a
03 to
q
St. Lucie County
D
EXTRUDED ALUM. ATTACH
w/ #BX1 114 S.M.S. 3' O.C.
lnl2'x024 ALUM CAP -/
2'*4' PT CONT. wl A&a WC' :REINS ® 6-
O.C. TO RIDGE BEAM & 1a/34' WOOD
SCREW TO EACH TRUSS
.024 ALUM ROOF - _ PARK MODEL DETAIL B
T RDATION YSI7'RENE7 wilaxi mALUALAo.c. RAIL .
_ INSULATION / EITRL EDALU3. ATTACH
N.T.S.'
R
THICK BONDED PANEL /
i'O' PTW amci'SMS ®4' INTO
NOTE EXTRUDED METAL&BONDED PANEL
MAK IZ SPAN BONDED PANEL \
j-1,wXOJL `MEORUDED FASCIA
EASTINGALUM. / ENSRNG CRGURER''"�
COL &BEAM - OVERHANG
oamAMNc
C?lneinrn-n-�Tinr .nnnr rnnr nrre a u�-e
MOBILE HOME ALUMINUM ROOF OVER PLAN FOR 185 MPH EXPOSURE C
D
vs
C.
.UM ROOF 2' RIDGED POLYSTYRENE INSULATION
27c4' WOOD TRUSS
24'O.C. wl W SHEATHING EXTRUDED ALUM.
r+ wl #BX1 1/4 S.M.S.3'
5/ii���� �BUTYI.
SEE
DETAILS.
j
2n4 P.T. wl #W'VJOOD
ATTACH RAIL
O.C.
RUBBER SEAL
GUTTER &
S1
SCREWS
® 12' O.C. TO
FASCIA wl 148)0
MAX 1B' O.H. TO EACH TRUSS
CONTINUOUS
2'FASCIATYP.
TAIL (off 24'O.C.
'
'
NOTE
FIRESTONE ISO 95t GL INSULATION BOARD MAY
BE USED IN LIEU OF THE POLYSTYRENE
INSULATION BOARD IN THE SAM€ 2' THICKNESS.
N
0
A
!
qq q
O�co
CN •.
i.WO
QN
C4 N
xscq
NO �!
r `
!
C1
rKr^^�
V,
i
CO O
Q
c 4
cl
vl
o
U
h
! N
^Y
F�gya
s, h
otiw
mN
W N
Oto
�
%O
obi
4
SHEET No.: S2 Of 2
$-'
OWNER:
NOT VALID UNLESS DATED
& SEALED WITH EMBOSSED
ENGINEER'S S
IZ/1011g
JAMES BUSHOUSE, P.E. PROFESSIONAL ENGINEER 2D311STATE OF FLORIDA
n'
ADDRESS:
79S3d:
CITY: STATE ZIP:
LOT# BLOCK# RANGE