Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 -FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE ROYALE Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE_COUN_TY City -,State, -Zip: - FT. PIERCE, FL , Permit Number: _ --SCANNED BY Owner: 3n �GVQ t,33l Design Location: FL, Fort Pierce Jurisdiction: St Lucie County:: St. Lucie (Florida Climate Zone; ] County 1. New construction or existing New (From Plans) 9. Wall Types(1688.7 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ft' b. Frame - Wood, Adjacent R=11.0 240.00 ft' 3. Number of units, if multiple family 1 c. N/A R= ft' 4. Number of Bedrooms 3 d. N/A R= ft' 5. Is this a worst case? Yes 10. Ceiling Types (1720.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1720.00 ft 6. Conditioned floor area above grade (ft') 1720 b. N/A R= ft' Conditioned floor area below grade (W) 0 c. N/A R= ft' 11. Ducts R ft' 7. Windows(155.4 sqft.) Description Area a. Sup: Attic, Rat: Attic, AH: Attic 6 325 a. U-Factor. SgI, U=0.54 115.42 ft' SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.55 40.00 ft' 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.25 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft' SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft' a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.316 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1720.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation- R=0.0 1720.00 ft' b. Conservation features EF: 0.970 b. N/A R= ft' None c. N/A R= ft' 15. Credits Pstat Glass/Floor Area: 0.090 Total Proposed Modified Loads: 56.15 PASS Total Baseline Loads: 56.24 I hereby certify that the plans and specifications covered by Review of the plans and SSE STgl� this calculation are in compliance with the Florida Energy specifications covered by this OF b Code. calculation indicates compliance y�ii„.tr��'' with the Florida Energy Code. roc, K'••,' .;?C^.',.•`°;<<O PREPAR D Y: Before construction is completedPW- r " DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in compliance Florida Statutes. !), with the Florida Energy Code. -- t''Op WS OWNER/A -� BUILDING OFFICIAL: \".t DATE: \ DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 4/312018 11:29 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 fpl�y pt4�oftw-are GOpY Page 1 of 5 FORM R405-2017 PROJECT Title: WYNNE THE ROYALE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1720 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE Rotate Angle: 135 Street: WYNNE DEV. Permit-Office:ST_-LUCIE-COUNTY— — -Cross-Ventilation: —No — - ----County: — —St-Lucie ------- Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUN_ I. _ 39_ 90 _ 70. 75 299. 62 .Low BLOCKS Number Name Area Volume 1 Entire House 1720 13760 SPACES Number . Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 BEDROOM 343 2744 No 0 1 1 Yes Yes Yes 2 WIC - 63 504 No 0 1 No Yes Yes 3 M;,BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 172 1376 Yes 0 1 No Yes Yes 5 „ BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 98 784 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 528 4224 No 0 1 Yes Yes Yes 10 BEDROOM 3 169 1352 No 1 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 343 ft' ___ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' -_ 0 1 0 3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0 56 ft' ___ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 172 ft' ____ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft' ___ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 42.6 ft 0 204 ft' _-_ 0 1 0 7 Slab-On=Grade Edge Insulatio ENTRY 6.3 ft 0 98 ft' _- 0 1 0 4/3/2018 11:29 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017. FLOORS ' # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY Eft 0 42 fN _- 0 1 0 9 Slab -On -Grade Edge Insulatio GREAT/DINING 48 ft 0 528 ft' _- 0 1 0 _10SIab-On-Grade. Edge Insulatio BEDROOM-3- 13 ft 0- - --- -169 ft' 0 - ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1813 ft' 286 ft' Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1720 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 343 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft' 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft' 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 172 ft' 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft' 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 204 ft' 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 98 ft' 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft' 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 528 ft' 0.1 Wood 10 Onder Attic (Vented) BEDROOM 3 30 Blown 169 ft' 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 N=>SE Exterior Concrete Block - Ext Ins®EDROOM 4.1 9 0 8 0 72.0 ft' 0 0 0.5 0 2 S=>NW Exterior Concrete Block - Ext Ins®EDROOM 4.1 29 0 8 0 232.0 ft' 0 0 0.5 0 3 W=>NE Exterior Concrete Block - Ext InS®EDROOM 4.1 14 0 8 0 112.0 ft' 0 0 0.5 0 4 S=>NW Exterior Concrete Block - Ext InsuM. BATH 4.1 8 0 8 0 64.0 ft' 0 0 0.5 0 5 N=>SE Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.5 0 6 N=>SE Exterior Concrete Block - Ext IndMDROOM 2 4.1 14 0 8 0 112.0 ft' 0 0 0.5 0 7 NE=>S Exterior Concrete Block - Ext In93ffDROOM 2 4.1 2 10 8 0 22.7 ft' 0 0 0.5 0 8 E=>SW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 9 0 8 0 72.0 ft' 0 0 0.5 0 9 SE=>W Exterior Concrete Block - Ext InfiffDROOM 2 4.1 2 10 8 0 22.7 ft' 0 0 0.5 0 10 S=>NW Exterior Concrete Block - Ext InfiffDROOM 2 4.1 14 0 8 0 112.0 ft' 0 0 0.5 0 _ 11 NE=>S Exterior Concrete Block - Ext Insul ENTRY 4.1 1 5 8 0 11.3 ft' 0 0 0.5 0 12 E=>SW Exterior Concrete Block - Ext Insul ENTRY 4.1 5 0 8 0 40.0 ft' 0 0 0.5 0 4/3/2018 11:29 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 3 of 5 FORM R4U*-ZU17 WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Belo w _ 13 S=>NW Exterior Concrete Block - Ext InsdV1UNDRY 4.1 6 0 8 14 N=>SE Exterior Concrete Block - Ext Insr REAT/DINI 4.1 28 0 8 15 W=>NE Exterior Concrete Block - Ext lnsGREAT/DINI 4.1 20 0 8 16 N=>SE Exterior Concrete Block - Ext IntRffDROOM 3 4.1 13 0 8 17 N=>SE Garage Frame - Wood BEDROOM 3 11 30 8 0 48.0 ft' 0 224.0 ft' 0 160.0 ft' 0 104.0 ft' 240.0 ft' 0 0 0.5 0 0 0.5 0 0 0.5 0 0 0.5 0.23 0.5 0 0 0 0 0 DOORS # Omt Door Type Space Storms U-Value Ft Width Height In Ft In Area 1 E=>SW Insulated ENTRY None .39 3 6 8 20 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 W=>NE 3 Metal Low-E Single Yes 2 S=>NW: 4 Metal Low-E Single Yes _ 3 E=>SW S Metal Low-E Single Yes 4 N=>SE 14 Metal Low-E Single Yes 5 W=>NE 15 Metal Low-E Single Yes 6 N=>SE 16 Metal Low-E Single Yes 0.54 0.25 N 0.54 0.25 N 0.54 0.25 N 0.54 0.25 N 0.55 0.25 N 0.54 0.25 N 32.4 ft' 1 It 0 in 6.9 ft' 1 It 0 in 23.2 ft' 1 It 0 in 36.8 ft' 1 ft 0 in 40.0 ft' 10 ft 0 in 16.2 ft' 1 ft 0 in 1 It 4 in Drapes/blinds 1 It 4 in None 1 It 4 in None 1 It 4 in None 1 It 4 in None 1 It 4 in None Exterior 5 None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 wo ft' 300 ft' 30ft 8ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse 'Proposed ACH(50) .000356 1605.3 88.13 165.74 .2598 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Duds 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr dm 0.85 1 sys#1 4/3/2018 11:29 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM - V FSEC- ' — — — Collector —Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS / -- Supply — — Return— Air CFM 25 CFM25 HVAC # V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 325 ft- Attic 85 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat:Y Ceiling Fans:Cooling Jan Venting Jan' Feb Feb [�X]] Mar r [ ] Jun [x] Jul [ [X� Aug [ [X� Sep [ ] Oct L J Oct Nov Nov Dee [ ] [X] Apr May Jun [)Jul I Aug [ Sep lxl X Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/3/2018 11:29 AM EnergyGauge® USA - FlaRes2017 Section R405.4.1 Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name:. WYNNE THE ROYALE Builder Name: WYNNE Street: WYNNE DEV. Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner. — - - Jurisdiction: Design Location: FL, Fort Pierce COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks orjoints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shallbesealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity with sealed. a material having a thermal resistance of R-3 per inch Knee walls shall be sealed. minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls < Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spa s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind ninqno and wiring Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Eledricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fire qnri kler cover niateq and wells or ceilmnas a. In aaamon, Inspemion ar log walls snail De In accordance with the provisions of ICC-400. 4/3/2018 11:29 AM EnergyGauge® USA- FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 FORM R405-2017 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the EnergyPerformance Index, the more efficient the home. WYNNE DEV., FT. PIERCE, FL, 1. New constructionor existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms. 5. Is this a worst case? 6. Conditioned floor area (ft') 7. Windows" Description a. U-Factor. Sgl, U=0.54 SHGC: SHGC=0.25 b. U-Factor: Sgl, U=0.55 SHGC: SHGC=0.25 c. U-Factor. N/A SHGC: d. U-Factor: N/A SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: 8. Floor Types a. Slab-On-Grade,Edge Insulation b. N/A c. N/A New (From Plans) 9. Wall Types Insulation Area Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1448.70 ft' b. Frame -Wood, Adjacent R=11.0 240.00 ft 1 c. N/A R= ft' 3 d. N/A R= ft' 10. Ceiling Types Insulation Area Yes a. Under Attic (Vented) R=30.0 1720.00 ft' 1720 b. N/A R= ft' Area c. N/A R= ft' 115 42 ft' 11. Ducts R ft' a. Sup: Attic, Ret: Attic, AH: Attic 6 325 40.00 ft' 12. Cooling systems kBtu/hr Efficiency ft' a. Central Unit 34.8 SEER:15.00 ft' 13. Heating systems kBtu/hr Efficiency a. Electric Heat Pump 34.8 HSPF:8.50 3.316 ft. 0.250 Insulation Area R=0.0 1720.00 ft' R= ft2 R= ft' 14. Hot water systems a. Electric Cap: 40 gallons EF: 0.97 b. Conservation features None 15. Credits Pstat I certify that Phis home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant feature i` Builder Signature: Date: Address of New Home:25'� CV a:A-S- ��5-M City/FL Zip: *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Email EnergyGauge tech support at techsupportgenergygauge.com or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters'. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/3/2018 11:29 AM EnergyGauge® USA - FlaRes2017 - Section R405.4.1 Compliant Software Page 1 of 1 wrightsoft® Project Summary Job: Entire House By: QUICK CALCS, INC. For. THE ROYALE WYNNE DEV., FT. PIERCE, FL _J yc� � � SCANNED Notes: BY St. Lucie County Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Inside db 70 OF Outside db Inside db 90OF 75 OF Design TD 28 OF Design TD 15 OF Daily range' Relative humidity L . 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 19898 Btuh Structure 18607 Btuh Ducts 6092 Btuh Central vent (0 cfm) 0 Btuh Ducts Central vent (0 cfm) 9204 Btuh 0 Btuh none on Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25990 Btuh Use manufacturer's data n Infiltration Rate/swing multiplier Equipment sensible load 0.95 26420 Stuh Method simplified Construction quality Average Latent Cooling Equipment Load Sizing Fireplaces 0 Structure 2182 Btuh Ducts 2516 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg Area (none): (ft-) 1720 1720 Equipment latent load 4697 Btuh Volume (fts) 14231 14231 Airchanges/hour 0.38 0.20 Equipment total load 31117 Btuh Equiv. AVF (cfm) 90 47 Req. total capacity at 0.70 SHR 3.1. ton Heating. Equipment Summary Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536A`030 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static'pressure Space thermostat Capacity balance point = 35 OF 8.5 HSPF 34600 Btuh @ 47°F 27 OF 1160 cfm 0.045 -cfm/Btuh 0.50 in H2O Backup: Input = 7 kW, Output = 23009 Btuh, 100 AFUE Make Caner Trade CARRIER AIR CONDITIONING Cond 25HBC536A'030 Coil FX4DN(B,F)037 AHRI ref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual airflow 1160 cfm, Air flow factor 0.042 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.86 Calculations approved byACCA to meet all requirements of Manual J 8th Ed 2017- age 1 �CA wrighttsoft Apr•10 P28:8a RightSuite0llniversal 201717.0.14 RSU08101 ...\Oulck Celcs\DocumentslWYNNE-ROYALE-REVISED.mp Celc=MJ8 Front Door faces: N wrightsoft Right-M Worksheet Job: Entire House Date:' QUICK CALCS, INC. By: 317 ST. LUCIE LM. FT. PIERCE, FL 34946 Phone: 772-466.8799 Fos 772-466-6796 Emil: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM Simed 180.9 ft 52.0 ft 3 Room height 9 8.3 ft d 8.0 ft heaVcool 4 Room dimensions _ 1.0 x 343.0 ft 5 Room area 1719.5 ft' 343.0 ft' Ty Construction U-lelue Or HTM Area Load number (BtulVfti°F) (BtuNft9 or perimeter (ft) (Btuh) operimeter (ft) (Btuh) Heat I Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 .'13A4= 0.143 in.4.00 , 2.55 677 524 2096 1333 72 72 288 183 .'IAo1om 1.270 n- .. 35.56 34.77 16 0 565 553 0 0 '0 0 4A5-2om. 0.770 n 21.56 19.31 38 0 815 - 730 0 0 0 . 0 W 13A4ocs 0143 ne 400 255 34 34 136 86 0 0 0 0 11 13A46cs 0143 Le ' 4 00 255 112 67 269 -. 171 0 =- 0 ., 0 1Acicm : -1270 a 956 •' 87:29 . 24 3 848 • :2082 . 0', 0: - 0 ..0 `. ;0 ,11D0 -. 0 390 , e, "r 10 92 .. 11:31 -21 o-- . •.21 229 . :':238 p0 - 0 ,.. `0 1 W 13AAocs 0143 se 400 256 23 23 91 58 0 .0 0 0 0 V1Iyy 134-0acs 1Aatom; ' -'0143 :.1.270 s s- �'.:. 400 '-35.56 .: Z55 -: 34.77 456 c: 449 ;`:1798 -=247. ' ' :.1143 :241 232 ;, 00. 90. ram-..0 V(/ 13AAocs 0.143 w 4.00 2.55 .7'.. 290 _-14 217 867 551 - 0-. 112 79 . 318 202 IL-CG 1P.c1an 1.270 w 35.56 55.25 33 4 1162 1606 33 2 1162 1806 4A5-2am 0.770 w 21.56 45.63 41 4 880 1862 0 0 0 0 P " ' ' .:0 091 ; -- 2.55 : 1.28 ,.:....224 --. : - 224 : 571 ' 287 '; 0 ,;;0 -.: 0 ,'i 0 F.722�A-�tPlmd. 0.9989 1720 1641 3989 343 - 343 307 . 796 ,_ , - ,: 27.69 ,. 0:00 _ ' - 1720 r' 181 ' ....5010 - .p .. - ,343 t :: 52 ' '' 1440 ,. 'l0 6 c)AED excursion 465 G88 Envelope lossfgain 17124 15595 4444 4245 12 a) Infiltration 2774 782 773 218 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 - 0 Applianceslother 20DO 0 Subtotal (lines 6 to 13) 19898 18607 5218 4463 Less eoderrel load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 Subtotal 19898 18W7 5218 4463 114 151 Duct loads 31% 4 % 1 6092 9204 31% 49% 1598 mil Total room load 25990 27810 6815 6671 Air required (cfm) 1160 1160 304 278 A ' wrightsoft• RlghtSuitoO Universal 201717.0.14 RSU08101 ...%Quick CalcsXDOcuments%WYNNE-ROYALE-REVISED.mp Calc=MJ8 Front Doorfaces: 2017-Apr-10 17:29:34 Page 1 wrightsoft• Right-J@ Worksheet Job: Entire House Date:' QUICK CALCS, INC. By: 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-488£799 Fax 772466-6796 Emil: OUICKCALCS@,AOL.COM 1 Room name WIC M. BATH Oft 8.0 ft 3 Room height 8.0 ft heat/cool 8.0 It heat/cool 4 Room dimensions 7.0 x 9.0 ft 7.0 x 8.0 7t 5 Room area - 63.0 W 66.0 ft' Ty Construction U-value Or HTM Area ye) Load Area Load (Btut✓W17) (Btuttlft°) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross I WP/S Heat Cool 6 43AAobs'- 0.143 ..n 4,00 2.55 0 0 0 0 0 0 6 0 1Ac1om - 1.270 n 35.56 34.77 0 0 0 0 0" 0. '.0 '.'0 4A5-2om 0.770 . n 21.65 19.31 0 0 0 0 0 0 0 0 W 13A4ocs 0143 ne 400 255 0 0 0 0 0 0 0 0 11 13A ocs: 0143 a 400 255 0 .0 _ 0 0 0 0 0 '0 1Actom-. :1270 a .3556 87:20 '11;31 ,.-0.-. r0- •0:.. .0 •0. '0` 0 .,0 ,11D0 _ j.::0390 e- .. -AO92 , - �0; ,_0' -. 0; .0 � 0 0 :.'` 0 ,. -�'0 W 13AAccs 0.143 se 4.00 255 0 0 0 0 0 -0 0 0 3.A-0acs ".- =;A 143 s 9": 4.00 ' 255 - O r 0 ". '0 0 -. ' 't64= 57 r- 228 %945 1270 , s �':35.56 .'3477 -..0 . 0 0. '0 7 t .Z , 247 �---i241 13A-0aca 0.143 w 4.00 255 0 0 0 0- 0 0 0 - 0 IL�Sa, 1Aclom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 105-2om 0.770 w 21.56 45,63 0 0 0 0 0 0 0 0 P ."' 12C-0svi„--- 0.091 .._.. 2.55 C; 1:28,.' .0 0. -. :. .0 0',.- 0' ... 0.. :"0 C 16AS0md 0.032 - 0.90 232 63 63 66 146 66 56 130 F, ., 22A-1p1 -. ,-0.989 '' - 27.69 :. 0.00 -... ' ; 63 =0 0 -, ,0 : 56 ,. ;-fl .50 .222 -"' = '10. 6 c)AED excursion -10 -39 EJ Iope loss/gain 56 136 747 477 12 a) Infiftration 0 0 119 34 b) Roomverdilation 0 0 0 0 13 Internal gams: Occupants @ 23D 0 0 0 0 Appliances/other 0 0 Subtotal fines 6 to 13) 56 136 866 511 Less edema] load 0 0 10 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 56 136 866 511 16 Duct loads 31% 49% 17 67 31% 490/6 265 25 3 Total mom load 74 203 1131 764 Air requred(dm) 3 8 60 32 p- wrigh- 2017-Apr-10 17:29:34 �gyp- tsofY A RlghtSuite® Universal 2017 17.0.14 RSU08101 Page 2 ...Quick CeleslDocuments\WYNNE-ROVALE-REVISED.mp Cale =MJ8 Front Door faces: N wrightsofr RiOW@ Worksheet Job: Entire House Date:' QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 7724M-6796 Em id: CUICKCALCSIAAOLCOM 1 Room name WCHEN BATH 2 Exposed wall 0 ft 6.0 ft 3 Room helght 8.0 it heat/cool 8.0 ft heaticool 4 . Room dmerlslons 1:0 x 172.0 ft _ 9.0 x 5.0 ft 5 Room area - 1720 ft- 45.0 ft2 Ty Construction U-value Or HTM Area Load Am M Load number (Btuwfti°F) (BtuWft2) or _ perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross WP/S Heat Cool 6 . 13AA= 0.143 . n .4.00 255 0 0 0 0 40 40 160 102 ; clan- 1.270 n 35.56 34.77 0 0 0 0- 0 0 ' :0 0 4A5-2om. - 0.770 , n 21.56 .19.31 0 0 0 0 0 0 0 0 w 13A-4= 0143 ne 400 255 0 0 0 0 0 0 0 0 11 w 13A4= 0143 a 400 -.255 0 0 0 0 0. 0 0 0 1Ac1om ...1270 a _; 13556 '87..29 '0 ..0 0. 0 0 0. ._. 0 ,.;:D ��1100 .0390 a :f 1092 :'11.31 -0 •.:. .'.0 :•0=. 0 .._..; - W 13AAccs 0143 se 4.00 255 0 0 0" 0 ' 0 0 0 0 Im -135,466s :� -,0143 a :'400" '258 0;`: 0 ": 0 .o: ;0"- 0:_;`'. a "-10 Ac 11am; .-::1.270.s -.3556: 34,77 0.. D-:-. a. '. 0 .0' 0-- 0: .1r0 VjI 13A4= 0.143 w 4.00 255 0 0 0 0 0 0 0 0 �C- �f 1A-c1om 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 4AS-2orn 0.770 w 21.66 45.63 0 0 0 0 0 0 0 0 ": P• i12C-0sw '-.... "16A30md ,:0.091 ,..__.... .55 ',...-.1:28 ',64... -. 066-.- .163; -82 p: 0. ^.0 «` -:=",0 C .. ,. 0.032 - 0.90 232 172 172 164 399 45 45 40 104 F ".71A-ipt. .,0.989 - ..:.27.69 � .. 0.00172' � 0 . � : � 0 _ . 0 `- � 45 - , "5:=' 138 SC ' '.°0 6 c)AED excursion -176 -16 Enoelope loss/gain 317 305 339 190 12 a) Infiltration 0 0 74 21 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appliances/other 2000 0 Subtotal (lines 6 to 13) 317 2305 413 211 Less eMemal load 0 0 -0 0 Less transfer 0 0 0 0 Redistdbution 0 0 0 0 14 Subtotal 317 2305 413 211 15 Duct loads 31% 49% 97 1140 31% 49% 127 104 Total room load 414 3446 540 315 Air required (cfm) 18 144 24 13 nth � wrightsoft- 2017-Apr-1017:29:34 RightNE-ROitegl Universal D.mp .0.o RJ8 Front Page3 ...\Oulck Celcs\DocurrentslWYNNE-ROYALS-REVISED.mp CaIc=MJB Front Door faces: N wrightsoft• Right-M Worksheet Job: Entire House Date:' QUICK CALCS, INC. By: 317 ST.. LUCIE LN, FT. PIERCE, FL 34946 Phone: 772-466-6799 Faoc 772-466-6796 Email: QUICKCALCSCc�AOLCOM 1 Room name BEDROOM 2 ENTRY 426 ft 6.3 ft 3 R=adwall height8.0 ft heat/cool 8.0 it heat/cool 4 Room dimensions 1.0 x 204.0 ft 1.0 -x 97.6 It 5 Room area 204.0 ft2. - 97.5 ft2 Ty Construction U-value Or HTM Area number (Btuh/WF) (Btuwft2) cr perimeter (it) (Btuuhh) or perimeter (ft) (Btuh) Heat Cocl Gross WP/S Heat Cool Gross WP/S Heat Cool 6 13A locs 0.143 n 4.00 2.55 112 112 448 285 0 0 0 0 1Actom - 1:270 n- 35.56 34.77 0 0 0 0 0 0 - '0 ' 0 4A5-2oth 0.770 n 21.55 19.31 - 0 0 0 0 0 0 0 . - 0 W lak4ocs 0.143 ne 400 2.55 23 23 91 58 11 11 45 29 11 W�'C' 113A-0acs 0143 a -. 400 .255 72 :� 48 - 193 123 40. 19-. 7648 1Ac1om -,: -,1270 a 3566 97.29 .24 - 2 -.. 848 `2082 0'. 0'.. 0 '•'o 1D 11D0 0390 a ... �10.92 11:31 0;, 0 0,_''0 .21 21 W - 13A-0oos 0143 se 4.00 255 23 23 91 68 0 0 0 0 Vy 13A4acs, -,:•' �tAcloin ,0143 s-.°. {. •4.00 266-', 112 ': 112" 448 "285 :.' 0" . 0 `_` 0 `0 L-4 ; 1.270 . s 35.56 `«. 34.77 :0 - 0 .. 0 0.- 0: 0 0...+0 VY 13A-0acs 0.143 w 4.00 255 0 0 0 0 0 0 0 0 1Aciom 1.270 w 35.56 65.25 0 0 0 0 0 0 0 0 L�GG 4A5-tom 0.770 w 21.66 45.63 0 0 0 0 0 0 0 0 -P•..` ;12COsw'--. '.0.091;'.- '255' -1.28: 0 • .. o .0 ,- o-:; .104 .. °t0a '.. 285 C 22Artpl 0.032 - 0.90 232 204 204 183 473 98 98 97 226 F ;f '-22A-tpl '0.989 ! -.- .. 27.69 :• .0.00 :204 . 43 '... 1179 0 98 :. 6 '.. 175 ': _ :..,. 0 6 c)AED excursion -90 sp Envelope loss/gain 3481 3273 878 625 12 a) Infiltration 634 179 95 27 b) Rcomvemlation 0 0 .0 0 13 Irdemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lures 6 to 13) 4115 3452 974 651 Less erdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 4115 3452 974 651 15 Duct loads 31% 49% 1260 1708 31% 49% 298 322 Total room load 5376 5159 1272 974 Air required (cfm) 240 215 ' 67 41 Calculations approved byACCA to meet all requirements of Manual J 8th Ed -Fk- wrightsoft. RlghtSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-10 17:29:34 ... lquiek CalcslDocumentslWYNNE-ROVALE-REVISED.mp Calc=M.18 Front Door faces: N Page 4 + wrightsoft' Right-M Worksheet Job: Entire House Date: ey: " QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-486-6799 Fax 77246U796 Email: QUICKCALCS@AOLCOM 1 Room name LAUNDRY GREAT/DJNNG ed wall 6.0 ft 48.0 ft 3 Room height 8.0 ft heat/cool 8.9 ft heaHcool 4 Room dimensions 7.0 x 6.0 ft. 1.0 -x 528.0 4t 5 Room area - 42.0 fN 528.0 fP Ty Construction U-value Or HTM Area Load Am (M Load number (Biumt-F) (Btutyft°) or perimeter (ft) (Stuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 , XL 13A4ccs `1Aclom 0.143 - n 4.00 255 0 0 0 - 0 249 211 846 538 1:270 n 35:56 '. 34.77 0 0 0 0 0 0 0 - 0 4A5-2om " 0.770 " a 21.56 19.31 0 0 0 0 38 - 0 815 730 w 13A4ccs 0143 ne 400 2.55 0 0 0 0 0 0 0 0 11 -13A-0acs 0143 a 4.00 255 0 0 0 0 0 0 0 0 " :lAclorn 1270 ' e ,- " 3556 '87.29 0 0., • � 0 • 0' 0' 0 � 0 " �. 2:0 11D0 - - ;J03w, e;..._ =1092 :-711:31 0 0'=•-:.p.' - '-0.,- ":0 ,. 0:...;'. w 13A4ocs 0143 se 400 255 0 0 0 0 0 0 .0 0 0 ' 1344ocs 10.143 .r-1.270 s ....' 4.00 .'2'55 "48 48 ' •: 192 --. 122 0 0 °.. , 0 - --`o 1Ac1an : s + ` 35.56 - 34:77', p ' 0. .. 0. . 0 0' "0 0 ---0 V+/ 13A-0ocs 0.143 w 4.00 255 0 0 0 0 178 137 549 349 1Aclom 1.270 w 35.56 55.25 0 0 0 0 0 0 0 0 II- 4A5-2an 0.770 w 21.56 45.63 D 0 0 0 41 2 880 1862 t12CGsvr > "' - . �:0.091 -' -F 255 .' 1i28 `- 66. :. "-.. 56 - -143: - - .. 72 . - -0 : 0 _ ': =.0 C 16A30md 0.032 - 0.90 232 42 42 38 97 .r0' 528 528 473 - -1225 ir F• 47/MtPP• -' .0.989 -' '27.69 0.00 '42', 6 -. .166, •0 ,528 "48 1328: '. ,.':-o 6 c)AE1 mursion -22 305 Envelops losslgain 539 269 4893 5008 12 a) Infiltration 89 25 794 224 b) Roomwrdilation 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 628 294 5687 5232 Less e#emal load 0 0 0 0 Less transfer p 0 p p Redistribution 0 0 0 0 14 Subtotal 628 294 5w 5232 15 Duct loads 31% 49% 192 146 31% 49% 1741 2588 Total mom load 82p 41 qqp 7428 7821 Air required (of,) 37 332 326 Calculations approved byACCA to meet all requirements of Manual J 8th Ed ,aA -Fj+ wrighisoR' RlghtSuitetf Universal 2017 17.0.14 RSU08101 2017-Apr.1017:29:34 Page 5 ...\Quick CalcslDocumentslWYNNE-ROYALS-REVISED.mp Cale =MJB Front Door faces: N wrightsoft- Right-M Worksheet Job: Entire House Date: QUICK CALCS, INC. By: 317 ST LUCIE LN., FT. PIERCE, FL 34946Phone: 772-46M799 Fax 77246"796 Email: 1 Room name BEDROOM 3 2 Fposed wall 13.0 ft 3 Room height 8.0 ft heal/cool 4 Room dimensions 13.0 x 13.0 ft - 5.. Room area _ 169.0 ft. Ty Construction U-value Or HTM Area Load number (Stuh/ftUF) (Bfutvftl or perimeter (ft) (Bl�uh) or perimeter Heat Cool Gross WRIS Heat Cool Gross WPIS Heat Cool 613A4ocs 1L-GG 0.143 n 4.00 2.55 104 88 353 224 - 1A;cl m - 1:270 n 35.56 34.77 16 0 565 50 4AS-2om- " 0.770 n 21.56 19.31 0 0 0 . 0 - W 13A4oce 0.143 ne 4 DO 2.55 0 0 0 0 11 13A-0acs 0.143 a 4.00 , 2.55 '0 0 0 0 1Actom . - =1.270 e, 35.56 ` 87.29 0 -0 "0 0 - 0 ' - ,11D0� .. • .. . 0.390 e" -'10.92 .11:31 . 0 `. 0 7.0 ,. W 13A-0acs 0.143 se 4.00 2.55 0 0 0 0 13AAdcs .0.143 s . ' 400 -2.55 .. ; 0 `' � 0 - 'p a 0 1Aciom c - -1i270 . s.:. '35.56 34.77 - 0 , ' _ 0 0 .0 . y! 13AAocsA,clom 0.143 w 4.00 2.550 0 0 0 tAclom 1.270 w 35.56 55.25 0 0 0 0 L�GG 4A5.2am 0.770 w 21.66 45.63 0 0 0 0 P. ' 12C-05w'..,.•.; _.. .0.091 :..,. - ;255. -1.20, ., 0.- ; :'0 .- `d0 .., b' C 16A30md `"` 0.032 - 0.90 2.32 169 169 151 .. 392 ^. F ' :' `22A-fpl. : -.0.989 : 27.69 =0:00 -.- 169 '. . 13 360 w. ..-. 0' .. _ ... 6 c)AED=ursion -103 Envelope loss/gain 1430 1066 12 a) Ilfilhation 193 55 b) Room ventilation 0 0 13 Internal gains: Occupams @ 230 1 230 Applianceslother 0 Subtotal Aires 6 to 13) 1623 1351 Less ertemal load 0 0 Less transfer 0 p Redistribution 0 0 14 Subtotal 1623 1351 15 Duct loads 31% 490A 497 668 Total room load 2120 2019 Air required (cfm) 95 84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed C -L# wrlghtsoR- Right2017-Apr-1017:29:34 A NNE- OYALUniversal D.m 17.0.c RJ8 Front Page8 ...10uick Calcs\Documents\WYNNE-ROVALE42EVISED.mp Calc=MJ8 From Door faces: N Duct System Summary JQb. wri�htsoft° ' Y rY Date: Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone:. 772-46M799 Faz 772-46M796 Email OUICKCALCWOLCOM eLroject Intormation For. THE ROYALE WYNNE DEV., FT. PIERCE, FL Heating Cooling External static pressure 0.50 in H2O 0.50 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0.50 in H2O 0.50 in H2O Supply / return available pressure 0.250 / 0.250 in H2O 0.250 / 0.250 in H2O Lowest friction rate 0.286 in/100ft 0.286 in/100ft Actual airflow 1160 cfm 1160 cfm Total effective length (TEL) 175 ft Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (Cfm) Design FIR Diam (In) H x W (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 540 24 13 0.351 4.0 OxO VIFx 27.3 115.0 st1 BEDROOM h 3408 152 139 0.286 7.0 OxO VIFx 40.1 135.0 st2 BEDROOM 2 IT 5376 240 215 0.343 7.0 OxO VIFx 30.8 115.0 Ed BEDROOM h 2120 95 84 0.371 6.0 0x0 VIFx 19.9 116.0 st1 BEDROOM -A h 3408 152 139 0.297 7.0 OxO VIFx 33.1 135.0 st2 ENTRY h 1272 57 41 0.485 4.0 0x0 VIFx 8.1 95.0 GREARDINING-A h 3714 166 163 0.300 7.0 0x0 VIFx 31.7 135.0 st2 GREATIDIMNG43 IT 3714 _ 166 163 0.309 7.0 OxO VIFx 27.1 135.0 st2 KITCHEN c 3446 18 144 0.376 7.0 OxO VIFx 18.1 115.0 st1 LAUNDRY h 820 37 18 0.369 4.0 OxO VIFx 20.4 115.0 st1 M. BATH h 1131 50 32 0.366 4.0 OxO VIFx 21.6 115.0 st1 wic c 203 3 8 0.309 4.0 Ox0 VIFx 1 26.6 1 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (n) Material Trunk st2 Peak AVF 639 613 0.286 814 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1103 1119 0:286 802 16.0 0 x 0 VtnlFix 2017- r10 17:29:35 _ MCA wrightsoft, RightSuBe® Universal 201717.0.14 RSU08101 Page 1 MCA... Calcs\Documents\WYNNE-ROYALE-REVISED.mp Cato =MJ8 Front Door faces: N Name Grille Size (in) -]- Htg (cfm) Clg (Cfm) TEL (ft) Design FR Veloc (fpm) I Diam (in) I H x W (n) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1160 1160 0 1 0 0 0 ox 0 VIFx wrightsoft' RigMSuite® Uaivarsal 2017 17.0.14 RSU08101 2017-Apr-10 17:Page 2 Page 2 ... \Quick C81cs1DaumentslWYNNE-ROYALE-REVISED.Iup Cale=MJ8 Front Doorfaces: N