Loading...
HomeMy WebLinkAboutMISC LETTERSBOARD OF COUNTY COMMISSIONERS LINDA BARTZ CHAIR DISTRICT 3 CATHY TOWNSEND VICE CHAIR DISTRICT 5 CHRIS DZADOVSKY DISTRICT 1 SEAN MITCHELL DISTRICT 2 FRANNIE HUTCHINSON DISTRICT 4 HOWARD TIPTON COUNTY ADMINISTRATOR DAN MCINTYRE COUNTY ATTORNEY MAILING ADDRESS 2300 VIRGINIA AVENUE FORT PIERCE, FL 34982 PHONE (772) 462-2822 TDD (772) 462-1428 FAX (772) 462-1 581 E-MAIL DLSONL@STLUCIECO.ORG April 18, 2019 Brian E. Sto 4917 Dr. F ierce, FL 34982 RE: Finished floor waiver Dear Mr. Stone: PLANNINGtnldD DEVELOPM SERVICES DEPARTMENT Planning Division C1� t qO3 SCANNED BY St. Lucie County _0604, Please accept this letter in response to your written request received April 11, 2019 to waive the finished floor elevation of 18" above the crown of the road. The waiver request is for a proposed detached garage for an existing single family home at 4917 Buchanan Dr., Fort Pierce. Pursuant to Section 7.04.01(C-3) of the St. Lucie County Land Development Code, the Planning and Development Services Director has the authority to grant administrative relief, when topographical conditions are such that compliance with this subsection would be impracticable or cause grade level conditions detrimental to adjacent or nearby property, consistent with the intent of the Flood Protection regulations and any other applicable portion of this Code. The Planning and Development Services Director has granted your request for administrative relief of the finished floor elevation based on the following determinations: 1 The property is in Flood zone X. 2 The center line of the adjacent road is 17' NAVD. 3 The existing finished floor elevation of the house is at 17.8' NAVD. 4 The proposed finished floor elevation for the detached garage is 16' NAVD which is 1' below the center line of the road but 1.5' above natural grade. The detached garage is proposed to be located approx. 235 ft. from the road. 5 The survey elevations indicates water will drain to the rear of the property to the dry detention area. 6 Raising the floor 18" above center line of the road would be impracticable and could cause conditions detrimental to adjacent or nearby property and to the existing single family residence. The proposed finished floor would require an additional 2.5' feet of fill. This approval does not in any way constitute authorization to begin construction. Prior to the commencement of any construction on this property, an application for specific building permit must be obtained from this department. Please feel free to contact me at (772) 462-2822 if you have any questions. ince 1 , Y L e Olson, Planning and Development Services Director cc: Monica Graziani, Building and Code Compliance Manager Gary Stepalavich, Building Official Melissa Brubaker, Zoning and Permitting Supervisor WEBSITE W W W.STLUCIECO.GOV Dear Leslie Olson Please review the letter pertaining to APR 1 12019 BY t�p5 our detached garage permit application at — -- 4917 Buchanan-Dr-Ft—Pierce;-FL-34982 Permit# 1903-0604. There is a conflict of the proposed elevation for our detached garage.The proposed elevation for the detached garage is 16.0 and the center line of road is 17.0 . According to Lydia Galbraith the minimum floor elevation is to be at 18" above center line of road. The survey I had performed it is obvious that the rainwater drains to the rear of the property. According to the architect we are in flood zone X. Please reconsider the proposed elevation of our detached garage. Thank You 4t) G!?z� o �/ l,112oi y Brian E Stone brianestone3Co)gmail.com 772-708-7890 FL Design Build Inspect CRC1331263IAA26003142iH110776 Architecture + Construction + Home Inspection 772.321.4500 1 frank.liebler@gmail.com 10/25/19, Field Rev R2 SCANNED To: St Lucie County Building Department BY St. Lucie County Re: permit # 19030604 1. The metal roof is changing to asphalt shingle per product approval. 2. All doors have changed per product approval. 3. Hardiboard will be used in lieu of Hardiplank on gable ends per product approval. Thankyou, Frank Liebler Owner / Architect / Contractor FL Design Build Inspect Construction + Architecture + Home Inspection CRC1331263 I AA26003142 I H110776 frank.liebler@gmail.com c 772.321.4500 fte C®Ay RECEIVED OCT 282019 ST. Lucie County, Permitting BLDG DEPT CORRESPONDENCE 11 of 1