Loading...
HomeMy WebLinkAboutPRODUCT APPROVAL AFFIDAVITSCANNED BY St. Lucie Countv PRO DUCT APPROVAL AFFIDAVIT- 4917BuchannanDr BUILDINGGLASS DPz PRODUCTDP TYPEs MFR MODEL•. DOOR OVERHEAD ALL 160,65 N/A I DAB Door Co 924 NOA 17-1108.31 DOOR S. SWING ALL 65,-65 IMPACT Plastpro any FL 17184 ROOFING UNDERLAYMENT ALL N/A GAF any FL 10626.1 -56 field, - -52.5 field, - ROOFING METAL ALL 79.6 edge 112.5 edge N/A Drexel Metals 5V FL 17678 1.'ID' as per door & window schedule, or all meaning worst case of all similar items of that type. 2. If building dp are left blank- see door & window schedule or design pressure chart. 3. This affidavit is only to verify product's compliance with wind loads. 4. Unless products are specifically submitted forverification by contractor, they are assumed. 5. If glass type is not specified more than 'Impact', may use any of the impact glass type in the install instructions to achieve the stated building design pressures. 6. If fasteners Is left blank, may use any of the specified attachment methods in the install instruction matching structure provided to achieve the stated building design pressures. 7. 1 have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. FRANK LIEBLER, ARCHITECT (AR97108) Igd3-oCc) I MAY 0 3 '18 Lucie County, permitting SCANNED BY St. Lucie Count PRODUCT APPROVAL AFFIDAVIT- 4917 euchannan Dr GLASS ITEM TYPE IDi BUILDING DP2 PRODUCT DP TYPE 5 MFR MODEL APPROVALh FASTNERS6 DOOR OVERHEAD ALL 43,49 N/A Janus Int. 3400 NOA 18-0123.13 DOOR S.SWING ALL 70,70 IMPACT Masonite any FL22513.7 ROOFING UNDERLAYMENT ALL N/A Tamko moisture guard FL 12328.4 ROOFING SHINGLES ALL 157 mph 194 mph N/A GAF any NOA 16-0811.11 SIDING SIDING ALL -36.7 -76 N/A James Hardie Hardiepanel NOA 17-0406.06 1.'ID' as per door & window schedule, or all meaning worst case of all similar items of that type. 2. If building dp are left blank- see door & window schedule or design pressure chart. 3. This affidavit is only to verify product's compliance with wind loads. 4. Unless products are specifically submitted for verification by contractor, they are assumed. 5. If glass type is not specified more than 'Impact', may use any of the impact glass type in the install instructions to achieve the stated building design pressures. 6. If fasteners is left blank, may use any of the specified attachment methods in the install instruction matching structure provided to achieve the stated building design pressures. 7. 1 have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. FRANK LIERLER, ARCHITECT (AR97108)