PRO DUCT APPROVAL AFFIDAVIT- 4917BuchannanDr
BUILDINGGLASS
DPz PRODUCTDP TYPEs MFR MODEL•.
DOOR OVERHEAD ALL 160,65 N/A I DAB Door Co 924 NOA 17-1108.31
DOOR S. SWING ALL 65,-65 IMPACT Plastpro any FL 17184
ROOFING UNDERLAYMENT ALL N/A GAF any FL 10626.1
-56 field, - -52.5 field, -
ROOFING METAL ALL 79.6 edge 112.5 edge N/A Drexel Metals 5V FL 17678
1.'ID' as per door & window schedule, or all meaning worst case of all similar items of that type.
2. If building dp are left blank- see door & window schedule or design pressure chart.
3. This affidavit is only to verify product's compliance with wind loads.
4. Unless products are specifically submitted forverification by contractor, they are assumed.
5. If glass type is not specified more than 'Impact', may use any of the impact glass type in the install instructions to achieve the stated building design pressures.
6. If fasteners Is left blank, may use any of the specified attachment methods in the install instruction matching structure provided to achieve the stated building design pressures.
7. 1 have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions.
FRANK LIEBLER, ARCHITECT (AR97108)
Igd3-oCc) I
MAY 0 3 '18
Lucie County, permitting
SCANNED
BY
St. Lucie Count
PRODUCT APPROVAL AFFIDAVIT- 4917 euchannan Dr
GLASS
ITEM TYPE IDi BUILDING DP2 PRODUCT DP TYPE 5 MFR MODEL
APPROVALh FASTNERS6
DOOR OVERHEAD ALL 43,49 N/A Janus Int. 3400
NOA 18-0123.13
DOOR S.SWING ALL 70,70 IMPACT Masonite any
FL22513.7
ROOFING UNDERLAYMENT ALL N/A Tamko moisture guard
FL 12328.4
ROOFING SHINGLES ALL 157 mph 194 mph N/A GAF any
NOA 16-0811.11
SIDING SIDING ALL -36.7 -76 N/A James Hardie Hardiepanel
NOA 17-0406.06
1.'ID' as per door & window schedule, or all meaning worst case of all similar items of that type.
2. If building dp are left blank- see door & window schedule or design pressure chart.
3. This affidavit is only to verify product's compliance with wind loads.
4. Unless products are specifically submitted for verification by contractor, they are assumed.
5. If glass type is not specified more than 'Impact', may use any of the impact glass type in the install instructions to achieve the stated building design pressures.
6. If fasteners is left blank, may use any of the specified attachment methods in the install instruction matching structure provided to achieve the stated building design pressures.
7. 1 have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions.
FRANK LIERLER, ARCHITECT (AR97108)