HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY:
DATE FILED: 1 0• Z -3 - I 1 PERMIT # I G t33 O(D N
REVISION FEE: OQ RECEIPT
PLANNING & DEVELOPMENT SERVICES RECEIVCU
BUILDING & CODE REGULATION DIVISION
2300 VIRGINIA AVENUE
FORT PIERCE, FL 34982.5652 OCT 2 8 Z019
(772) 462.1553 ST. Luae County, Permitting
APPLICATION FOR BUILDING PERMIT REVISIONS
PROJECT INFORMATION SCANNED
BY
LOCATION/SITE St. Lucie County
ADDRESS--
1-igl- 150rlpNnL3 17� Fl Voec<c FL_. Sgojg2a
DETAILED DESCRIPTION OF PROJECT
CONTRACTOR INFORMATION:
STATE of FL REG./CERT. #:
BUSINESS NAME:
QUALIFIERS NAME:
ADDRESS:
CITY:
PHONE (DAYTIME):
NAME: I'
ADDRESS
CITY: 9'+
PHONED
STATE:
ARCIHTECT/ENGINEER INFORMATION:
NAME: >C(-&„r It
ADDRESS:
CITY: STATE: _
PHONE (DAYTIME): -1-)a U l L1 S�0
SLCCC: 9123109
Revised 06130117
-,new 6 0 /&feclb
0Nde.:ic-yMP,#-
ST. LUCIE CO CERT. #:
IAI:F�
FAX:
ZIP:
ZIP:
,Florida Building Code Online
Page 1 of 2
i a
. 0 -
r ' r
KIS Home I Wg In i User ft"Is"ilon Hat Toplcs Submit Sa¢harye Rats It Facts Publlcabpns FX Stag i aCIS Site Map ❑pks Sear li
F10 _
(p Product Approval
ar Vm — USER: Public User
- _
PmEact Approval Mene>proEUR er Avol raryan�e+.�M1>poollcatlan Llst>Appllcationlle[e)I file Copy
FL # FLI0626-R13
Application Type Revision n A =ram
Code Version 2017 Svn!.f z
Application Status Approved BY
Si. Lucie County
Comments
Archived p
Product Manufacturer GAF
Address/Phone/Email ICampus Drive REVIEWED FOR
Parsppany, NJ 07054
m e00eh@gaf.com CODE COMPLIANCE
Authorized Signature Robert Nieminen ST. LUCIE COUNTY
®C(_
Iindarei[h@[rinityero17
.mm `T�j/�jt/A",`j''f/'y�J,'
Technical Representative William Broussard
Address/Phone/Email 1 Campus Drive
Parsippany, NJ 07054 / (/
(800) 766-3411 4 i
TechnicelQuestionsGAF@gaf.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Undedayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 05/19/2018
Validated By John W. Knezevich, PE
10 Validation Checklist - Hardcopy Received
Certificate of Independence FL10626 R13 COI 2017 01 COI Nieminen odf
Referenced Standard and Year(of Standard) Standard Vear
ASTM 01970
2015
ASTM 06164
2011
ASTM D6757
2016
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
TAS 103
1995
Equivalence of Product Standards
Certified By
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 V%... 12/14/2017
,Florida Building Code Online
Page 2 of 2
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
09/22/2017
09/29/2017
10/03/2017
12/12/2017
FL #
Modelr Number or Name
Description
10626.1
GAF Roof Underlayments
Roofing Undenayments for use in sloped roof systems
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
EL10626 R13 II 2017 09 FINAL ER GAF UNDERLAYMENTS FL10626-
R33,odr
Impact Resistant: N/A
Verified By: Robert Niemien 59166
Design Pressure: +N/A/--45.0
Other: 1.) The design pressure noted in this
Created by Independent Third Party: Yes
Evaluation Reports
application relates to one particular
underlayment system for use under foam -on
FL10626 R13 AE 2017 09 FINAL ER GAF UNDERLAYMENTS EL10626-
R13.odf
tile systems. Refer to ER Section 5.6.4 for
details. 2.) Refer to ER Section 5 for other
Created by Independent Third Party: Yes
Limits of Use.
Back Next
contact us 2601 Blair sure Road, Ta a -see n 32349 Phone• 850,482,1824
The state of Florida Is an AAIEEO anployer. ronvrteht 2007-2013 State of Florida,:: privacy Statement :: Appesiabritestatement :: RePond Statement
Under Florida law, email addresses are public records. If you do not want your a -mall address released in response to a publlo-records neatest, do not send
electronic mall to INS sadly. instead, contact Me office by phone or by traditional mail. If you have any Vendors, please contact 850.487.1395. *%noram to
Section 455.275(t), Florida Statutes, effective, October 1, 2012, thoraces licensed under chapter 455, F.S. must provide Me Department Won an enlal address if
May have one. The counts poNded may be dead far official cvnmuumtion with Me licensee. However email addresses are Public tem,d. If you do not wish M
supply a personal address, please provide Me Department Man an email address vMM can be made avallable to Me public. To determine If you are a licensee under
Product Approval Accepts:
® on w
SCCurl tylUE''TRICS
http://www.floridabuilding.orgtpr/pr_app_dtl.aspx?param=wGEVXQwtDgtBNbEY5 Ve/D... 7
/
ENGINEER EVALUATE TEST
NEMO l etc.
Certificate of Authorization N32455
353 Christian Street, Unit#13
Oxford, CT 06478
(203)262-9245
CONSULT CERTIFY
EVALUATION••
GAF Evaluation Report 01506.04.08-1115
1Campus Drive
Parsippany, NJ 07054
(800)766-3411
FL10626-R35
Date of Issuance:04/25/2008
Revision 15: 04/22/2019
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 6" Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: GAF Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality
Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO l etc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOletc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 11.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
un;, ,.
Lr.,
>o,A 3-M:
y2 �r3na-sar--+"'
v" _
=�•., en-o�ap
The facsimile seal appearing was authorised by Robert
8'.o•—*•%-X,*y'
Nlernmen,P.E.on 04/22/2019. This does not serve as an
electronically signed document.
CERTIFICATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not awned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ONEMOletc.
ROOFING COMPONENT EVALUATION:
Product Category: Roofing
Sub -Category: Underlayment
Compliance Statement: GAF Roof Underlayments, as produced by GAF, have demonstrated compliance with the
following sections of the Florida Building Code through testing in accordance with the following Standards.
Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
Section
Pro a
Standard
Year
1504.3.1
Wind Uplift
FM 4474
2011
1507.1.1, R905.1.1 Exception
Unrolling, Breaking Strength,
ASTM D226
2009
Pliability
1507.1.1, R905.1.1 Exception
Tear Strength
ASTM D4533
2015
1507.2.3 / 1507.1.1
Physical Properties
ASTM D6757
2016
1507.2.4 / 1507.1.1, 1507.2.9.2
Physical Properties
ASTM D3970'
2015
1507.3.3, R905.3.3
Physical properties
FRSA/TRI April 2012 (04-12)
2012
1507.11.2
Physical Properties
ASTM D6164
2011
Enti
Examination
Reference
Date
ERD (TST 6049)
Physical Properties
113360.02.07-2-111
03/13/2007
ERD (TST 6049)
Physical Properties
G12110.12.08
12/02/2008
ERD (TST 6049)
FRSA/TRI April 2012 (Slippage)
G34150.08.11
11/14/2011
ERD (TST 6049)
ASTM D6164
G40630.01.14-2B
01/07/2014
ERD (TST 6049)
ASTM D6164
G46160.09.14-3A
09/09/2014
ERD (TST 6049)
ASTM D1970
GAF-SC13285.03.17-3
03/01/2017
ERD (TST 6049)
ASTM D1970
GAF-SC13285.03.17-4
03/01/2017
PRI (TST 5878)
Physical properties
BRY-003-02-01
03/19/2002
PRI (TST 5878)
ASTM D1970
GAF-026-02-01
03/26/2002
PRI (TST 5878)
ASTM D1970
GAF-027-02-01
03/26/2002
PRI (TST 5878)
Physical properties
GAF-042-02-01
06/03/2005
PRI (TST 5878)
Physical properties
GAF-224-02-01
07/27/2009
PRI (TST 5878)
ASTM D1970
GAF-238-02-01
03/03/2010
PRI (TST 5878)
ASTM D1970
GAF-275-02-01
11/11/2010
PRI (TST 5878)
Physical properties
GAF-349-02-01
07/03/2012
PRI (TST 5878)
Wind Uplift
GAF-434-02-01
09/16/2013
PRI (TST 5878)
Wind Uplift
GAF-434-02-03
09/16/2013
PRI (TST 5878)
Wind Uplift
GAF-434-02-04
09/16/2013
PRI (TST 5878)
FBC 1507.1.1 (Exception)
GAF-818-02-01
12/05/2017
PRI (TST 5878)
FBC 1507.1.1 (Exception)
GAF-826-02-01
06/04/2018
PRI (TST 5878)
FBC 1507.1.1 (Exception)
GAF-847-02-01
06/04/2018
PRI [TST 5878)
FBC 1507.1.1 (Exception)
GAF-914-02-01
04/10/2019
UL (TST 1740)
Physical properties
02NK22569
06/04/2002
UL (TST 1740)
ASTM D6757
1ONK11990
05/18/2011
Miami -Dade (CER 1592)
HVHZ compliance
16-1216.02
02/02/2017
Miami -Dade (CER 1592)
HVHZ compliance
18-0119.15
02/22/2018
ICC-ES(EVL2396)
IBC/IRC compliance
ESR-2053
07/01/2017
ICC-ES (EVL2396)
IBC/IRC compliance
ESR-2808
07/01/2017
ICC-ES (EVL2396)
IBC/IRC compliance
ESR-1322
01/01/2018
ICC-ES (EVL2396)
IBC/IRC compliance
ESR-3286
02/01/2018
UL, LLC (QUA 9625)
Quality Control
Service Confirmation
12/17/2018
NEMO ETC, LLC Evaluation Report 01506.04.08-R35
Ceniflmte OfAuthori:4tion #32455 S-EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R35
GAF Roof Underlayments; (800) 766-3411 Revision 15: 04/22/2019
Page 2 of 11
M
4.1
4.2
4.3
4.4
4.5
4.6
4.7
4.8
4.9
4.10
4.11
ONEMOletc.
PRODUCT
Description
- - -Product
Specification
Plants)
LibertyT" SBS Self -Adhering
ASTM D1970
Mt. Vernon, IN
smooth -surfaced, fiberglass -reinforced, self-
Base/Ply Sheet
adhering SBS modified bitumen roof
underlayment
StormGuard® Film Surfaced
ASTM D1970
Mt. Vernon, IN
film -surfaced, fiberglass -reinforced, self -
Leak Barrier
Savannah, GA
adhering SBS modified bitumen roof
underlayment; also used as a secondary
water barrier to seal roof decks
WeatherWatche Mineral
ASTM D1970
Mt. Vernon, IN
mineral -surfaced, fiberglass -reinforced, self -
Surfaced Leak Barrier
Savannah, GA
adhering SBS modified bitumen roof
underlayment; also used as a secondary
water barrier to seal roof decks
VersaShield® Fire -Resistant
ASTM D6757
Conover, NC
non -asphaltic, fiberglass -based roof
Roof Deck Protection
(physicals)
underlayment and/or fire barrier
Deck -Armory" Premium
FBC 1507.1.1 &
North Bay, ON
non -woven, spun -bonded polypropylene
Breathable Roof Deck
R905.1.1
Dadra, India
laminated polyethylene scrim sheet roof
Protection
(Exception)
underlayment
RoofProT" SBS-Modified All-
AC165
Fontana, CA
fiberglass-reinforced,SBS modified bitumen
Purpose Underlayment
roof underlayment
Shingle -Mate® Roof Deck
FBC 1507.1.1 &
Pryor, OK
fiberglass reinforced, asphaltic roof
Protection
R905.1.1
underlayment
(Exception)
StormSafeT" Anchor Sheet
FBC 1507.1.1 &
North Bay, ON
polypropylene woven fabric which serves as
R905.1.1
an anchor sheet in two-ply roof
(Exception)
underlayment systems
Tiger Paw' Roof Deck
FBC 1507.1.1 &
Dadra, India
non -woven, polypropylene reinforced,
Protection
R905.1.1
North Bay, ON
polymer coated roof underlayment
(Exception)
Ruberoid® Mop Granule
ASTM D6164
Savannah, GA
granule -surfaced, polyester -reinforced,
asphalt -applied SBS modified bitumen roof
underlayment
Ruberoid® Mop Granule FR
ASTM D6164
Savannah, GA
granule -surfaced, polyester -reinforced,
asphalt -applied SBS modified bitumen roof
underlayment
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory or test
report from accredited testing agency for fire ratings of this product.
NEW ETC, LLC Evaluation Report 01506.04.08-R1S
CertlTmte ofAuthoriration 9324SS OEDITION (2017) FBC NON-HVHZ EVALUATION FL10626-RIS
GAF Roof Underlayments; (800) 766-3411 Revision I5: 04/22/2019
Page 3 of 11
ONEMOjetc.
5.4 GAF Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to theAuthorityHaving Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers:
TABLES: ROOF COVER OPTIONS
Asphalt
Foam -On
Wood
Slate or
Underlayment
Nail -On Tile
Metal
Shakes&
Simulated
Shingles
Tile
Shingles
Slate
Deck-ArmorT" Premium Breathable
Contact
Contact
Contact
Roof Deck Protection
Yes
No
No
GAF
GAF
GAF
RoofPrOTM SBS-Modified All -Purpose
Underlayment
Yes
No
No
No
Yes
Yes
Shingle -Mate® Roof Deck Protection
Yes
No
No
No
No
No
Tiger Paw"' Roof Deck Protection
Yes
No
No
Contact
Contact
Contact
GAF
GAF
GAF
VersaShield° Fire -Resistant Roof Deck
Protection
Yes
No
No
No
No
No
Liberty'" SBS Self -Adhering Base/Ply
Sheet
Yes
No
No
No
No
No
StormGuard® Film Surfaced Leak
Barrier
Yes
No
No
Yes
No
No
WeatherWatch® Mineral Surfaced
Leak Barrier
Yes
No
No
No
No
No
Ruberoid® Mop Granule
Yes
Yes
Yes
No
Yes
Yes
See 5.5.1
Ruberoid® Mop Granule FR
Yes
Yes
Yes
No
Yes
Yes
See 5.5.1
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT _COMBINATIONS'
Adhesive
Florida Prod uCtApproval
Underlayments
Dow TileBOnd'"
FL22525
Ruberoid® Mop Granule; Ruberoid° Mop Granule FR
5.6 Allowable Substrates:
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAYMENTS
Underlayment
Application
Primer
Substrates
Liberty'" SBS Self -Adhering Base/Ply Sheet
self -adhering
(Optional)
ASTM D41
plywood
StormGuard® Film Surfaced Leak Barrier
Weather Watch® Mineral Surfaced Leak Barrier
Liberty'" SBS Self -Adhering Base/Ply Sheet
self -adhering
None
ASTM D226 felt
StormGuard® Film Surfaced Leak Barrier
Weather Watch® Mineral Surfaced Leak Barrier
Liberty'" SBS Self -Adhering Base/Ply Sheet
self -adhering
ASTM D41
metal (flashing metal, valley metal, etc.)
StormGuard® Film Surfaced Leak Barrier
Weather Watch® Mineral Surfaced Leak Barrier
' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report 01506.04.08-R35
Certffmte of AuthoriioHon#32455 rEDITION (2017) FBC NON-HVHZ EVALUATION FL10626-RIS
GAF Roof Underlayments; (800) 766-3411 Revision 15: 04/22/2019
Page 4 of 11
ONEMIDIetc.
TABLE 2: SUBSTRATE OPTIONS FOR ADHERED UNDERLAVMENTS
- - — Underlayment- - - -- - -
-Application -
Primer
Substrates
Ruberoid® Mop Granule
hot asphalt
ASTM D41
structural concrete
Ruberoid® Mop Granule FR
Ruberoid® Mop Granule
hot asphalt
None
GAFGLAS® P80 UltimaTM Base Sheet or
Ruberoid® Mop Granule FR
Ruberoid® 20 Smooth
5.6.4 Wind Resistance for Underlavment SVstems in Foam -On Tile Applications:
The following wind uplift limitations apply to underlayment systems that are not prescriptively addressed in
FRSA/TRI April 2012 (04-12) and are used in foam -on or mortar -set tile applications. Maximum Design Pressure is
the result of testing for wind load resistance based on allowable wind loads and reflects the ultimate passing
pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI
April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure =-45 psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima'M Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min.
1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 9-inch o.c. at the
min. 4-inch wide side laps and 9-inch o.c. at two (2), equally spaced, staggered center rows in the
field of the sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
#2 Maximum Design Pressure =-75psf.
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima'M Base Sheet or Ruberoid® 20 Smooth mechanically attached with 12 ga., min.
1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 8-inch o.c. at the
min. 4-inch wide side laps and 8-inch o.c. at three (3), equally spaced, staggered center rows in the
field of the sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square. ,
#3 Maximum Design Pressure=-97.5 DO
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Sheet: GAFGLAS® #80 Ultima'M Base Sheet or Ruberoid® 20 Smooth mechanically attached with it ga., min.
1.25-inch long ring shank nails through 32 ga., 1-5/8-inch diameter tin caps spaced 4-inch o.c. at the
min. 2-inch wide side laps and 4-inch o.c. at four (4), equally spaced center rows in the field of the
sheet.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
#4 Maximum Design Pressure = -442.5 osf.
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction
Base Sheet: GAFGLAS #75 Base Sheet, Tri-Ply #75 Base Sheet, GAFGLAS #80 Ultima Base Sheet, GAFGLAS Ply 4,
Tri-Ply Ply 4 or GAFGLAS Flex Ply 6 applied in full mopping of ASTM D312, Type IV hot asphalt at 20
to 25 Ibs/square.
Cap Sheet: Ruberoid® Mop Granule or Ruberoid® Mop Granule FR applied in full mopping of ASTM D312, Type
IV hot asphalt at 20 to 25 Ibs/square.
NEMO ETC, LLC Evaluation Report 01506.04.08-1135
Certi/lrate a7Authorliatlon 9324SS 6"EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R35
GAF Roof Underlayments; (800) 766-3411 Revision 15: 04/22/2019
Page 5 of 11
ONEMOletc.
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or
exceed that required under FRSA/T.RI April 2012.(04-12), Appendix. A, Table 1A.—
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment
density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used
methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117.
Assemblies marked with an asterisk` carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention
Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
5.7.1 Deck-ArmorTM Premium Breathable Roof Deck Protection; RoofPrOTM SBS-Modified All -Purpose Underlayment;
Shingle -Mate® Roof Deck Protection; StormSafe' Anchor Sheet and Tiger Pavv M Roof Deck Protection shall not
be left exposed for longer than 30-days after installation.
5.7.2 VersaShieldO Fire -Resistant Roof Deck Protection, Ruberoid® Mop Granule and Ruberoid® Mop Granule FR shall
not be left exposed for longer than 180-days after installation.
5.7.3 LibertyTM SBS Self -Adhering Base/Ply Sheet; StormGuarde Film Surfaced Leak Barrier and WeatherWatchO Mineral
Surfaced Leak Barrier shall not be left exposed for longer than 30-days after installation.
5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)):
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
6.1
6.2
6.3
6.4
6.5
TABLE 3:T_ILE SLIPPAGE LIMITATIONS FORDIRELT-DECK TILE INSTALLATIONS
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Ruberoid® Mop Granule
Flat
Max. 30-tile stack
4:12
Flat
Max. 6-tile stack (4 over 2)
5:12
Lugged
Max. 10-tile stack
5:12
Ruberoid® Mop Granule FR
Flat or Lugged
Max. 6-tile stack (4 over 2)
5:12
Lugged
Max. 10-tile stack
4:12
GAF Roof Underlayments shall be installed in accordance with GAF published installation instructions subject to
the Limitations set forth in Section 5 herein and the specifics noted below.
Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris prior to application and prime the substrate (if applicable).
Install self -adhering underlayments when ambient temperatures are minimum 45°F and rising.
All metal surfaces shall be primed with Matrikm 307 Premium Asphalt Primer or alternate GAF accepted ASTM
D41 primer prior to application of self -adhering membranes.
I Deck -Armor" Premium Breathable Roof Deck Protection: I
6.5.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for
double -layer applications.
6.5.2 Fasteners:
Minimum fasteners shall be 1-inch diameter plastic -capped corrosion resistant nails or 1-inch diameter plastic -
capped, corrosion resistant staples, unless restricted by Code.
Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails
shall be required where the ultimate design wind speed, VaaI4 equals or exceeds 150 mph."
NEMO ETC, LLC Evaluation Report 01506.04.08-R75
Certiftcare o7AuthaRioaon#32455 6TM EDIT] ON (2017) FBC NON-HVHZ EVALUATION FL10626-R15
GAF Roof Underlayments; 1800) 7663411 Revision 25: 04/22/2019
Page 6 of 11
ONEMOjetc.
6.5.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches: End (vertical)
laps shall be offset from course to course not less than 6 feet.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch o.c.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.5.4 Slopes of 2:12 to less than 4:12:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 28.5-inches (for 54-inch
wide rolls) or minimum 25.5-inches (for 48-inch wide rolls). End (vertical) laps shall be offset from course to
course not less than 6 feet.
Begin by fastening a half -width starter strip along the eaves or install full -width leak barrier. Place a full -width
sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 28.5-
inch side laps (for 54-inch wide rolls) or minimum 25.5-inch side laps (for 48-inch wide rolls), resulting in a
double -layer application.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch D.C.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.5.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of LibertyTM SBS Self -Adhering
Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at
vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and
valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment,
leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed
decking. At other areas, install the leak barrier over the underlayment.
6.6 Tiger Paw m Roof Deck Protection:
6.6.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width for
double -layer applications.
6.6.2 Fasteners:
Minimum fasteners shall be 1-inch diameter plastic -capped corrosion resistant nails or 1-inch diameter plastic -
capped, corrosion resistant staples, unless restricted by Code.
Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails
shall he required where the ultimate design wind speed, t oufn equals or exceeds 150 mph."
6.6.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch D.C.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.6.4 Slopes of 2:12 to less than 4:12:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 25.5-inches. End
(vertical) laps shall be offset from course to course not less than 6 feet.
Begin by fastening a half -width starter strip along the eaves or install full -width leak barrier. Place a full -width
sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 25.5-
inch side laps, resulting in a double -layer application.
NEMO ETC, LLC Evaluation Report 01506.04.08-1135
Certffcote o/Authoriratlon a32455 6TH EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-RlS
GAF Roof Underlayments; (800) 766-3411 Revision 15: 04/22/2019
Page 7 of 11
ONEMOjetc.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch o.c.
When batten systems are to be installed atop the underlayment,_ the underlayment need only be preliminarily
attached pending attachment of the battens.
6.6.5 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty`" SBS Self -Adhering
Base/Ply Sheet; StomnGuard's Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at
vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and
valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment,
leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed
decking. At other areas, install the leak barrier over the underlayment.
6.7 StormSafem Anchor Sheet:
6.7.1 StormSafeTM' Anchor Sheet is limited to use as a mechanically attached base layer in 2-ply underlayment systems.
6.7.2 Fasteners:
Minimum fasteners shall be 1-inch diameter plastic- or steel -capped corrosion resistant nails; corrosion -resistant
nails & 1-5/8-inch tin -caps; or Drill-Tec screws and plates, unless restricted by Code.
Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails
shall be required where the ultimate design wind speed, V /t, equals or exceeds 150 mph."
6.7.3 Starting at the eave, fasten the eave edge and 6-inch wide end -laps 6-inch o.c. Fasten in the field of the roll 12-
inch o.c. in two, equally spaced, staggered center rows.
Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps.
Fasten 6-inch o.c. in the laps and 12-inch o.c. in two, equally spaced, staggered center rows in the field. Ensure
all end laps are staggered at least 3-feet apart.
One the same day, install LibertyTM SBS Self -Adhering Base/Ply; StormGuard® Film Surfaced Leak Barrier or
WeatherWatch® Mineral Surfaced Leak Barrier over the StormSafeT" Anchor Sheet.
6.8 RoofProT" SBS-Modified All -Purpose Underlayment and Shingle -Mateo Roof Deck Protection:
6.8.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or 11 underlayment in FBC Table
1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed.
6.8.2 Fasteners:
As required in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed. No hammer
tacks or staples are permitted.
Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails
shall be required where the ultimate design wind speed, Vaal, equals or exceeds 150 mph."
6.8.3 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of Liberty" SBS Self -Adhering
Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced Leak Barrier at
vulnerable leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and
valleys, install the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment,
leaving 6 to 8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed
decking. At other areas, install the leak barrier over the underlayment.
NEMO ETC, LLC Evaluation Report 01506.04.08-R15
Cenifcate o)Author/iatlon 432455 V-EDITION (2017) FBC NON-HVHZ EVALUATION FL10626-R15
GAF Roof Underlayments; (800( 766-3411 Revision 15:04/Z2/2019
Page 8 of 11
ONEMOjetc.
6.9 VersaShield® Fire -Resistant Roof Deck Protection:
6.9.1 Shall beinstalledin compliance with the codified requirements for ASTM D6757 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.9.2 Fasteners:
Minimum fasteners shall be 1-inch diameter plastic -capped or metal -capped corrosion resistant nails or 1-inch
diameter plastic -capped, corrosion resistant staples, unless restricted by Code.
Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: "...except metal cap nails
shall be required where the ultimate design wind speed, Vaal, equals or exceeds 150 mph."
6.9.3 Slopes of 4:12 or greater:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4-inches. End (vertical)
laps shall be offset from course to course not less than 6 feet.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch o.c.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.9.4 Slopes of 2:12 to less than 4:12:
End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 22-inches. End
(vertical) laps shall be offset from course to course not less than 6 feet.
Begin by fastening a half -width starter strip along the eaves or install full -width leak barrier. Place a full -width
sheet over the starter, completely overlapping the starter course. Continue upslope, maintaining minimum 22-
inch side laps, resulting in a double -layer application.
Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. Secure end laps 6-inch o.c.
When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily
attached pending attachment of the battens.
6.9.5 Optional, or if required by the Authority Having Jurisdiction: Install a leak barrier of LiberWm SBS Self -Adhering
Base/Ply Sheet; StormGuard® Film Surfaced Leak Barrier or WeatherWatch® Mineral Surfaced at vulnerable
leak areas, including but not limited to eaves, valleys, rakes, skylights and dormers. At eaves and valleys, install
the leak barrier prior to installation of the underlayment. Along the rake, install the underlayment, leaving 6 to
8-inch of the deck exposed, and then install the leak barrier over the underlayment and exposed decking. At
other areas, install the leak barrier over the underlayment.
6.10 Liberty- SBS Self -Adhering Base/Ply Sheet:
6.10.1 Shall be installed in compliance with the codified requirements for ASTM D2970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.10.2 The minimum and maximum roof slopes are %:12 and 6:12, respectively. Back -nailing is required when slope is
1:12 or greater. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c.
encapsulated within min. 3-inch side laps.
6.10.3 Non -Tile Applications:
Shall be fully self -adhered to the substrates noted in Section 5.6. For direct -bond to deck applications plywood
shall be primed with MatrixTM 307 Premium Asphalt Primer or alternate GAF accepted ASTM D41 primer at''/: to
% gallon per square.
Prior to removal of release film, align sheets properly starting at the low -point of the roof leave) with the selvage
edge upslope and for minimum 2-inch overhang at eaves and rakes. Roll out sheet and allow to 'relax'for min. 30
minutes. Remove the lower piece of release film and bond to substrate and fold the overhanging 2-inch over the
eave and nail into place 12" o.c. Remove the top piece of release film and bond to substrate. Install primed drip
edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch troweling of MatrixTM 201
Premium SBS Flashing Cement over drip edge.
NEMO ETC, LLC Evaluation Report 01506.04.08-RSS
Certificate ofAutharkation a32455 6n' EDrnON (2017) FBC NON-HVHZ EVALUATION FL10626-R35
GAF Roof Underlayments; (800) 766-3411 Revision 15:04/22/2019
Page 9 of 11
ONEMOJetc.
Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps.
Ensure all end laps are staggered at least 18-inch apart.
Use a weighted lawn or linoleum roller to ensure complete adhesion to the substrate. Use a hand roller to firmly
bond side and end laps.
6.11 StormGuard® Film Surfaced Leak Barrier:
6.11.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.11.2 Back -nailing is required. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c.
encapsulated within min. 3-inch side laps.
6.11.3 Non -Tile Applications:
Shall be fully self -adhered to the substrates noted in Section 5.6. Prior to removal of release film, align sheets
properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch
overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the
overhanging 2-inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to
substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch
troweling of MatrixTM 201 Premium SBS Flashing Cement over drip edge.
Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps.
Ensure all end laps are staggered at least 18-inch apart.
Use a hand roller to firmly bond side and end laps.
6.12 WeatherWatch® Mineral Surfaced Leak Barrier:
6.12.1 Shall be installed in compliance with the codified requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.12.2 WeatherWatch® Mineral Surfaced Leak Barrier may be installed as a secondary water barrier using minimum 4-
inch wide rolls to seal plywood deck joints prior to installation of the primary underlayment system.
6.12.3 Back -nailing is required. Back -nailing shall consist of minimum 1-inch square or round cap nails spaced 18" o.c.
encapsulated within min. 4-inch side laps.
6.12.4 Non -Tile Applications:
Shall be fully self -adhered to the substrates noted in Section 5.6. Prior to removal of release film, align sheets
properly starting at the low -point of the roof (eave) with the selvage edge upslope and for minimum 2-inch
overhang at eaves and rakes. Remove the lower piece of release film and bond to substrate and fold the
overhanging 2-inch over the eave and nail into place 12" o.c. Remove the top piece of release film and bond to
substrate. Install primed drip edge and fasten to meet FBC Chapter 16 wind load requirements. Install 1/8-inch
troweling of Matrix'°' 201 Premium SIBS Flashing Cement over drip edge.
Continue upslope in a similar manner, maintaining minimum 3-inch side -laps and minimum 6-inch end -laps.
Ensure all end laps are staggered at least 18-feet apart.
Use a hand roller to firmly bond side and end laps.
NEMO ETC, LLC Evaluation Report 01506.04.08-RiS
Certlfitnre OfAufarl+odon R32455 6-EDmON 120171 FBC NON-HVHZ EVALUATION FL10626-RSS
GAF Roof Underlayments; 18001766-3411 Revision 15: 04/22/2019
Page 10 of 11
ONEMOjetc.
6.13 Ruberoid® Mop Granule; Ruberoid® Mop Granule FR:
6.13.1 Ruberoid® Mop Granule or Ruberoid® Mop Granule FR shall be installed in compliance with current GAF
published installation requirements.
6.13.2 For use in tile applications, Ruberoid® Mop Granule or Ruberoid® Mop Granule FR are for use as an alternate to
"Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the "Single Ply System" from FRSA/TRI April 2012 (04-
12) beneath mechanically fastened tile roof systems or the Hot Asphalt applied "Cap Sheet' in the "Two Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered tile roof systems.
6.13.3 Fully adhere in ASTM D312, Type IV hot -asphalt to the substrates noted in Section 5.6. Side laps shall be
minimum 4-inch and end -laps minimum 6-inch wide, and offset end -laps minimum 3-feet from course to course.
Side and end -laps shall be fully adhered in a complete mopping of hot asphalt with asphalt extending
approximately 3/8-inch beyond the lap edge.
6.13.4 Consult GAF instructions regarding back -nailing requirements.
6.14 Tile Staging (Ruberoid® Mop Granule; Ruberoid® Mop Granule FR):
6.14.1 Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment.
Refer to Table 3 herein, and GAF published requirements for tile staging.
6.14.2 Battens and/or Counter -battens, as required by the tile manufacturer and FRSA/TRI April 2012 (04-12) must be
used on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or
nail -boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this
product.
Contact the manufacturer or the named CIA entity for plants covered under Rule 61G20-3 QA requirements.
Refer to Section 4 herein for product & production locations having met codified physical properties
specifications.
9. QUALITY ASSURANCE ENTITY:
UL,LLC.— QUA9625; (847) 664-3281
END OF EVALUATION REPORT -
NEMO ETC, LLC Evaluation Report 01506.04.0E-1135
Certl77cote of Authorization #32455 rEDITION (2017)FBC NON-HVH2 EVALUATION FL10626-RIS
GAF Roof Underlayments; 1800) 766-3411 Revision 15: 04/22/2019
Page 11 of 11
Pale Copy
MIAn'II-DADE COUNTY
i'iIAMHIXt1i:E -
_
M
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMY C RESOUKCE$(REA)
Miami, Florida 33175-2474
BOARD AND_CODE.ADMINISTRATIONDIVISION `` _ —_<o ��.. �
Eh
786)-315-2590 F (786) 315-2599
FO
NOTICE OF ACCEPTANCE (NOA) _' _�.,;'®-
�w.miamidade.eov/economy
GAF
1 Campus Drive
Parsippany, NJ 07054
COUNTY
BOCC
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to
revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: GAF Timberline HD®, Timberline® Natural Shadow" Timberline® American Harvest®, and
FortitudeIrm Shingles
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews and revises NOA # 14-1022.20 and consists of pages 1 through 6.
The submitted documentation was reviewed by Alex Tigera.
NOA No.: 16-0811.11
Expiration Date: 02/21/22
.Approval Date: 02/09/17
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Cateeorv:
Roofing
Sub-Cateeorv:
Asphalt Shingles
Materials:
Laminate
Deck Tyne:
Wood
SCOPE
This approves GAF Timberline HD®, Timberline® Natural Shadow®, Timberline American® Harvest®, and
FortitudeTm Shingles as manufactured by GAF as described in this Notice of Acceptance.
PRODUCT DESCRIPTION
Product
Dimensions
Test
Product Description
Specifications
GAF Timberline HD®
13 1/4"x 39 3/;
TAS 110
Fiberglass reinforced heavy weight asphalt
Manufacturing
roof shingle, with a laminate profile
Locations #1; 2, 3, 4, 5, 6, 7
GAF Timberline Natural
13 W'x 39 3/;
TAS 110
Fiberglass reinforced heavy weight asphalt
Shadow®
roof shingle, with a laminate profile
Manufacturing
Locations #1, 2, 3, 4, 5, 6, 7
GAF Timberline® American
13 '/4"x 39 3/8"
TAS 110
Fiberglass reinforced heavy weight asphalt
Harvest®
roof shingle, with a laminate profile
Manufacturing
Locations #2, 4, 5, 6
GAF Fortituderm
13'/4"x 39 3/;
TAS 110
Fiberglass reinforced heavy weight asphalt
Manufacturing
roof shingle, with a laminate profile
Location 94
MANUFACTURING LOCATION
1. Tampa, FL
2. Michigan City, IN
3. Baltimore, MD
4. Myerstown, PA
5. Ennis, TX
6. Tuscaloosa, AL
7. Dallas, TX
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 2 of 6
EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Renort
Date
Underwriters Laboratories,LLC
ASTM D3462
4787344101
07/25/16
Underwriters Laboratories, Inc.
ASTM D3462
11CA48924
10%24/11
Underwriters Laboratories, Inc
ASTM D3462
10CA21994
04/22/11
Underwriters Laboratories, Inc
ASTM D3462
IOCA28717
07/26/11
Underwriters Laboratories, Inc.
ASTM D3462
05CA47541
11/10/06
Underwriters Laboratories, Inc.
ASTM D3462
06CA31580
11/30/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF-101-02-02
11/02/05
Underwriters Laboratories, Inc.
ASTM D3462
06NK05159
08/09/06
PRI Asphalt Technologies, Inc.
ASTM D3462
GAF-098-02-02
11/08/05
Underwriters Laboratories, Inc.
ASTM D3462
02NK41809
08/11/02
Underwriters Laboratories, Inc.
ASTM D3462
03NK26444
10/17/03
Center for Applied Engineering
ASTM D3462
257989
05/13/97
Underwriters Laboratories, Inc.
TAS 107
OINK45803
04/13/94
Underwriters Laboratories, Inc.
TAS 107
06NK05159
08/09/06
Underwriters Laboratories, Inc.
TAS 107
04NK04273
02/20/04
Underwriters Laboratories, Inc.
TAS 107
05CA42840
11/11/05
Underwriters Laboratories, Inc.
TAS 107
02NK41811
11/11/02
Underwriters Laboratories, Inc.
TAS 107
03CA35209
10/17/03
Underwriters Laboratories, Inc.
TAS 107
04CA13850
08/30/04
Center for Applied Engineering
TAS 100
257989
04/01/97
PRI Asphalt Technologies, Inc.
TAS 100
GAF-044-02-01
01/13/04
PRI Asphalt Technologies, Inc.
TAS 100
GAF-098-02-01
11/08/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-101-02-01
11/09/05
PRI Asphalt Technologies, Inc.
TAS 100
GAF-116-02-02
03/23/06
PRI Asphalt Technologies, Inc.
TAS-100
ELK-083-02-01
10/16/02
ELK-084-02-01
10/ 15/02
ELK-085-02-01
10/14/02
ELK-086-02-01
10/24/02
ELK-087-02-01
10/21/02
ELK-088-02-01
10/16/02
ELK-107-02-01
10/09/03
ELK-108-02-01
10/09/03
ELK-109-02-01
10/09/03
LIMITATIONS
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for
fire ratings of this product.
2. Shall not be installed on roof mean heights in excess of 33 ft.
3. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code
and Rule 61G20-3 of the Florida Administrative Code.
NOA No.: 16-0811.11
MIAMI-DADE COUNTY
... � , Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 3 of 6
INSTALLATION
1. Shingles shall be installed in compliance with Roofing Application Standard RAS 115.
2. Flashing shall be in accordance with Roofing Application Standard RAS 115
3' -The manufacturer'shail provide -clearly written application instructions. - - -
4. Exposure and course layout shall be in compliance with Detail'A', attached.
5. Nailing shall be in compliance with Detail W, attached.
LABELING
Shingles shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of
manufacturing facility, and following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade
County Product Control Seal as shown below.
BUILDING PERMIT REQuiRmENTS
1. Application for building permit shall be accompanied by copies of the following:
1.1 This Notice of Acceptance.
1.2 Any other documents required by the Building Official or the applicable code in order to properly
evaluate the installation of this system.
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 4 of 6
L
DETAIL A
COURSE LAYOUT
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 5 of 6
DETAIL B
OVERALL DIMENSIONS AND NAILING PATTERN
39-3/811
(1m)
(360-445mm) (360-445mm)
13-1 /4" s-,/z" - 9-1/2" s-12" - s-1/2"
{ms-armnl lies-btmn)
33]mm) + + �— —
1?-2-12'
a3-
ENHANCED NAILING PATTERN - six nails per shingle*
' required by some local codes and required far enhanced wind coverage on certain products.
See limited warranty for details.
These shingles MUST be nailed a nominal 6" (152mm) from bottom of
of shingle, above the cut outs, as shown. Nails must not be exposed.
END OF THIS ACCEPTANCE
Nail guide line
5-314' - 6-0/4'
(146mm-159mm)
from bottom of shingle
Self seal
adhesive
on back
NOA No.: 16-0811.11
Expiration Date: 02/21/22
Approval Date: 02/09/17
Page 6 of 6