Loading...
HomeMy WebLinkAboutEVALUATION REPORTEXTERIOR RESEARCH &DESIGN, U.C. Certificate of Authorization #9503 TRp;��y,/` SCANNED 353 CHRISTIAN STREET, UNIT N13 I 1 9 ERD BY OXFORD, CT 06478 St. Lucie County (203) 262-9245 EVALUATION REPORT TRI-BUILT Materials Group, LLC PO Box 70 Rutherford, N1 07070 (800)516-1485 Evaluation Report A42960.10.12-R6 FL16048-R6 Date of Issuance: 10/Z5/2012 Revision 6: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governingthe use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nleminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6`h Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity I ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle.. ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity( ERD Evaluated" may bedisplayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall beprovided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the. request of the Building Official. This Evaluation. Report consists of pages 1 through 6. Prepared by: Robert I.M. Nieminen, P.E. Florida Registration No. 59165, Florida DCA ANE1983 iEe nk f.xalaPPeaXry wm au'Wrr<N bla kx Nlemumn, LlUer••, P.E.onW/ZS/IDil. Thud«a rot serve esen ele.4onkaiN a$ned d.am t CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products R evaluates. 2. Trinity l ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a buildingcode evaluation. Neither Trinity I ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING COMPONENT EVALUATION:. 1. SCOPE: 2. � TRINITY � ERD Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 6's Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations/ Conditions of Use set forth herein. STANDARDS: Section 1504.3.1 1504.3.1 1504.6 1507.2.4 / 1507.1.1, 1507.2.9.2 1507.3.3 REFERENCES: KlIfity ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) FRO (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) ERD (TST6049) UL, LLC. (QUA9625) UL, U.C. (QUA9625) Property Wind Resistance Wind Uplift Accelerated Weathering Physical Properties Physical Properties Examination Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Physical Properties Accelerated Weathering Wind Resistance Quality Control. Quality Control Standard FM 4474 UL 1897 ASTM G155 ASTM D1970 FRSA/TRI April 2012 (04-12) Reference S40540.02.13-1 S40540.11.13 540540.03.14 S44870.04.14-2 S44870.04.14-3 S44870.04.14-1 S44870.04.14-4 S43530.02.14-1-R1 S43530.05.14 S40540.10.14 SC7645.02.15 SC8520.04.15 SC14045.05.17-RI Muhiple-Listing R16814 Service Confirmation Year 2021 2012 2005 2015 2012 Date 02/19/2013 11/19/2013 03/26/2014 04/02/2014 04/02/2014 04/10/2014 04/10/2014 05/14/2014 05/28/2014 10/31j2014 02/13/2015 OS/27/2015 06/07/2017 12/10/2015 Exp.07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SRS modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970. 4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinityl ERD nor Robert N)eminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to elrrent Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 CertTsmtc ofAuthorizoNen n9503 6°i EDITION(2017) PBC NON-HVHZ EVALUATION F116048-R6 TRI-BUILT Roof Underlayments;(800)516-1485 Revision 6: 09/ZS/2017 Page 2 of 6 I �\-TR1Nrr 1 ERD 5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof -cover where the -product is specifically referenced within FBC approval documents. if not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: '.TABLEV ROOF COVER OPTIONS I Underlayment Asphalt Nail -On Tile Foam -On Tile Wood Shakes Metal 1 Slate Shingles & Shingles Tri-Built Sand-R SA Shingle ( Underiayment Yes No No No Yes Yes Ye i Tri-Built S/A HT TU Underlayment es Yes 5 ee b.5.1 ow es , Tri-Built Smooth HT S/A Underlayment yes No No Yes Yes Yes 5-5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. „3;-„TA6lEIA.ALLOyVABIF TRE-ADH6lyE/UNDERi.AY3ltENT CO(V181 M1IAAONSt S` -._. Adhesive Florida Product Approval Underiayments ICP Adhesives Polysete AH-160 FL6332 Tri-BuiR 5/A HT TU Underlayment Dow TileBond"' FL22$25 Tri-Built S/A HT TU Underlayment 516 Allowable Substrates: 5.6.1 Direct -Bond. to Deck: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HTTU Underlayment orTri-Built Smooth HT S/A Underlayment applied to: > Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC recommends. priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -insulation: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: > Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. Forinstallation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D or TAS 114, AppendixJ. r Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, LLC. Evaluation Report=96010.1bR6 Certificate oJAuthothadon J 503 eEOMON(2017)FBC NON-HVHZ EVALUATION FL16048-116 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6:09125/2017 Page 3 of 6 ' TRINITYj ERD 5.6.3 Bond to Mechanically Attached -Base .Layer: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: > ASTM D226, Type I or II felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Application : FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure=-45.0 osf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HTTU Underlayment, self -adhered. #2 Maximum Design Pressure=-67.5 osf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri-Built S/A HTTU Underlayment, self -adhered. #3 Maximum Design Pressure=-150.Ousf: Deck: Min. 15/32-inch APA-rated BCx plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR. PRIMER Underlayment: Tri-Built S/A HT TU Undertayment, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging. at side and end -laps. #4 Maximum Design Pressure=-60.0 Dsf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Underlayment: Tri-Built S/A HTTU Underlayment, self -adhered. Exterior Research and Design, U.C. Evaluation Report A42960.10.12-R6 Certificate of Authorisation N9503 e EDITION (2017) FEIC NON-tIWZ EVALUATION FL36048-116 TRI-BUILT Roof Underlayments; (800) 526-1485 Revision 6: 09/25/2017 Page 4 of 6 '\f' TRINITY ERA I 5.6.4.1. For mechanically attachedBaseSheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left exposed for longerthan 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-121): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. r TABLE 2:TILE SLIPPAGE UMfTAT10N5fOg DIRECT -DECK TILE'INSTAEtATIONSM Underlayment Tile Profile Staging Method Maximum I Slope Flat Max.10-tile stack 6:12 Lugged Max. 10-tile Stack 5:12 Max. 10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) Tri-Built S/A HT TU t ;e Underlayment Lugged v n, s Exterior Research and Design, LLC. Evaluation Report A42960.10.12-R6 Certyriane OfAuthcrieotion N9503 6r"EDITION (2017)FBC NON-HVHZ EVALUATION F116B48-RG TRI-BUILT Roof Underlayments;(800) 516-1485 Revision 6: 09/29/2017 Page 5 of G TRINi1Y ERD 6, —INSTALLATION:- - -- - ----- --- - - -- -- - - -- - 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in Section S herein and the specifics noted below. .. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust.and debris prior to application, and primethe substrate (if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlavment; Tri-Built S/A HT TU Underlavment or Tri-Built Smooth HT S/A Underlavment: 6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile applications: While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the. final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately10 ft of membrane and peel back the first 3 it of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with TRI-BUILT Materials Group, LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the overlap area at the top of the sheet at 124nch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge In each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile AoolicationstTri-Built S/A HT TU Underlavment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents file slippage and/or damage to the underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Gulfport, MS 9. QUALITY ASSURANCE ENTITY: UL, LLC-QUA9625;(314)578-3406;k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation ReportA42960.10.12-R6 CerVflmte afAuthorization#9503 6e' EDITION(20171 FBC NON-HVHZ EVALUATION n16048-116 TRI-BUILTRoof Underlayments;(800)516-1485 Revision 6: 09/25/2017 Page 6 of 6