Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEw� J LE Planni & e elo ment erv' s . e art nt • Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-1553 Certification for Design Load Compliance SCANNED BY Project Name: St h...:.._Goui Project Address: t.?3D y/ �44 %t/-P— Permit#: I qO.'3 — 062 6 Occupancy Type: Construction Type: INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. • Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph X ASD _LRFD End Zone Width: 6 ft 5. Mean Roof Height ft Roof Pitch: 6 :12 Parapet: N/A It 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, dearly label on all plan openings): Zone 1: +20,-31.8 Zone 2: +20,-55.3 Zone 3: +20; 81.7 Zone 4: +30.7,J7.6 Zone 5:+34.7, 46.5 Garage: +2e.5,-q4.8 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NA PSF Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF 8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not: Aspect Ratio <4:1 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design forces s Donald J. Nuelle 52046 mature; Date, and eai " ,VJ Revised 07/25/2014 Print Name Nuelle Engineering Cert # & Co. Cert Auth. 11634 SW Rowena Sir, P.S.L., FL 34987 Company Name & Address