Certification for Design Load Compliance SCANNED
BY
Project Name: St h...:.._Goui
Project Address: t.?3D y/ �44 %t/-P—
Permit#: I qO.'3 — 062 6 Occupancy Type: Construction Type:
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
• Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply)
1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10
2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open
3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D
4. Design Wind Velocity 160 mph X ASD _LRFD End Zone Width: 6 ft
5. Mean Roof Height ft Roof Pitch: 6 :12 Parapet: N/A It
6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, dearly label on all plan openings):
Zone 1: +20,-31.8 Zone 2: +20,-55.3 Zone 3: +20; 81.7 Zone 4: +30.7,J7.6 Zone 5:+34.7, 46.5 Garage: +2e.5,-q4.8
7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NA PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PSF
8. Were Shear Walls Considered For Structure? Yes x Not Applicable Explain Why Not:
Aspect Ratio <4:1
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? Yes
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces s
Donald J. Nuelle 52046
mature; Date, and eai "