Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method SCANNED Project Name: MW-279 Builder Name: GHO HOMES Street: 3304 BENT PINE DR Permit Office: SAINT LUCIE COUNTY -- - -BY -- City, State, Zip: FORT PIERCE, FL, 34951 Owner: Permit Number: / 9� 62 Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (2510.9 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 2218.50 ft2 b. Frame - Wood, Adjacent R=11.0 292.44 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2611.0 sgft.) Insulation Area a. Under Attic (Vented) R=40.0 2611.00 ft2 6. Conditioned floor area above grade (ft2) 2611 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(464.4 sgft.) Description Area a. Sup: Attic, Rat Attic, AH: Main 6 942 a. U-Factor: Dbl, U=0.62 464.36 ft2 SHGC: SHGC=0.26 b. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC:' a. Central Unit 60.0 SEER:16.00 ` c. U-Factor. N/A ft2 SHGC: 13. Heating systems k8tu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COPA.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2611.0 sgft.) Insulation Area EF: 0.900 a. Slab -On -Grade Edge Insulation R=0.0 2611.00 ft2 b. Conservation features b. N/A R= fP None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.178 Total Proposed Modified Loads: 84.12 PASS Total Baseline Loads: 83.78 I hereby certify that the plans and specificati ns covered by Review of the plans and ST,12! this calculation are in cam liance ith the Ft ride Energy specifications covered by this O�TlLE „ , E OA Code. calculation indicates compliance with the Florida Energy Code. � mur'�'•�. +•`ir'+;,•^. � O PREPARED BY: Before construction is completed DATE: 141 this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as de igned, is in compliance Florida Statutes. with the Florida Energy Code. COD WTi'i�� OWNER/AGENTTjj:111W BUILDING OFFICIAL: DATE: 4� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greate 50 C 50 (RQ02,4.1.2py PR 2 -- 9) 3128/2019 8:26 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-279 Bedrooms: 3 User Conditioned Area: 2611 Total Stories: 1 1 Worst Case: No GHO HOMES Rotate Angle: 0 SAINT LUCIE COUNTY Cross Ventilation: No Whole House Fan: No Single-family New (From Plans) Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 3304 BENT PINE DR County: St. Lucie City, State, Zip: FORT PIERCE, FL, 34951 CLIMATE J Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2611 24282.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 Main 2611 24282.3 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 224.4 ft 0 2611 ft- -_- 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emitt Deck Pitch Tested Tested Insul. (deg) 1 Hip Flat tilelslate 2920 ft' 0 ft' Medium 0.4 N 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2611 ft' N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 2611 ft' 0.1 Wood 3/28/2019 8:26 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 5 m m W V T Ot A W N� g m m Zm z GG ^ m m x m m m W O) O 01 A A A W w W N p y rg OV Z 3 O O O O O O O D 3 3 3 3 3 3 9 9 9 9 K T » m m m m m m m m m m m m m m m_ 3 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 m m m m m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 o 0 0 c C G G c C C c C C C C C C C p o m m m m m m m W W W W Ca W W 0 0 0- 0 F F F F F F n m m m m m m m m m m m m m m m o m d d d d d d d d d d d d d d d jI1 x t0 d d d W. d M. y h h h h h N h h h h h h h h h n h m V. T. O K C J m h rn rn rn 0000000000a0000 0 mCm m m m m m m m m mmm m m m 2 N m O Z T O O m A N A A Z Z Z Z Z z Z Z Z Z z z z z Z m h fp G m 0 0 0 do W W O O C O O V ^ O O O O O O O O O O O O O O O A N G m O O O O O O O O N J 6 (JO m o 0 0 0 0 0 0 3 z z z z z z z z z z z z z z z N �, m 0 J 0 J 0 J 0 J 0 J 0 J 0 J 0 J 0 J 0 J 0 J 0 J 0 J 0 J 0 J m S � m m m m m o 0 0 0 0 0 0 0 0 (n A O D Z Z Z Z Z Z Z Z Z Z Z Z Z Z Z N al O O O O O O O O O O O O O O O mi d m m 7 m 0 m J m J m J m J m J m J m J m J m J m J m J m p> O m O 0 O 0 O O O O of 0 A A O U1 N O V FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000384 2630.6 144.42 271.59 .2912 6.5 - --HEATING SYSTEM - - - - - # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unitt Split SEER: 16 60 kBtu/hr 1800 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.9 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Carl # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft2 DUCTS —Supply— V # Location R-Value Area —Return---- Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT ON RLF HVAC# Heat Cool 1 Attic 6 942 tt2 Attic 818 f12 Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable ThermostatCooling an: ']Y [FebrX'] Marr VentiNov ng HJ Jan [ ] FFebeb [X] Mar Ceiling Fans: rI Junrj rj Au r[X]� r Apr [ May [XJ Jun [X] Ju Jul [ Aug [ ] Sep Oct Nov[rX,] [X] Nv Dec H Dec 3/28/2019 8:26 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Healing (WD) AM 66 66 -66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 It 0.3 Main Name: Signature: Rating Compant: Date: 3/28/2019 8:26 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 100 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 60.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2611 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 34.0 c) Area 7c. 464.4 a) Split system heat pump HSPF ' b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) Ba. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.90 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11 a. 40.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has coi saving features which will be ii display card will be completed Builder Address of New Home: with the Florida Building Code, Energy Conservation, through the above energy i (or exceeded) in this home before final inspection. Otherwise, a new EPL on installed code compliant features. Date: 4I2.11q City/FL Zip: FORT PIERCE, FL 34951 3128/2019 8:26:45 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 F�+ wrightsoft• Load Short Form Entire House Project Information For: MW-279 3304 BENT PINE DR, FORT PIERCE, FL 34951 Job: Date: Feb 7, 2019 By: Design Htg Clg Infiltration Outside db(°F) 43 90 Method Simplified Inside db (°F) 70 72 Construction quality Tight Design TD (°F) 27 18 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 i4w Moisture difference (gr/lb) 0 68 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.6 kW 29480 Stuh 17 OF 1550 cfm 0.048 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make Carrier Trade 16 SEER PURON AC Cond CA16NA048""A Coil FV4CNB006 AHRI ref 4585139 Efficiency 14.0 EER, Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio 16 SEER 32550 Btuh 13950 Btuh 46500 Btuh 1550 cfm 0.045 cfm/Btuh 0 in H2O 0.72 ROOM NAME Area (ft) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 370 5833 5275 281 240 HER WIC 87 1249 756 60 34 HIS WIC 44 47 241 2 11 GREAT ROOM 428 5117 5397 247 246 DINING 159 3011 2867 146 130 FOYER 57 1268 1013 61 46 NOOK 139 2568 2285 124 104 KIT 164 172 1666 8 76 BED 3 149 1612 2964 78 135 BED3WIC 33 1060 630 51 29 CABANA 76 2090 1775 101 81 BED 2 188 1860 3099 90 141 BATH 2 59 1032 1172 50 53 UTILITY 49 116 708 6 32 MECH 36 463 642 22 29 KAACTCD DATu OAA ACc4 oe�n •... .v. r.�v..... r�� -�uVi Vu/u GGJ IVJ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-07 17:16:53 wrightsoft' Right -Suite® U niversal 201212.1.05 RSU02618 Page 1 /ivCil CAUsersUasonlDocumentslWrlghtsoft HVACWW-279 AVALCN.rup Cale =MA Front Door faces:N Entire House 2283 32159 34069 1550 1550 Other equip loads 0 0 Equip. @ 0.95 RSM 32366 Latent cooling 13150 TnTnl C I o000 onnrn I eruc I �rcn I •ccn Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Feb-0717:16:53 wrightSOft RIghtSulte® Universal 201212.1.05 RSU02818 Page )m C:\Usem%JasonlDocuments\Wnghtsoft HVACWW-279 AVALON.tup Calc=MJ8 Front Door faces: N +�- wrightsoftProject Summary Entire House Project Information For: MW-279 3304 BENT PINE DR, FORT PIERCE, FL 34951 Notes: Weather: Winter Design Conditions Outside db Inside db Design TD Vero Beach, FL, US Job: Date: Feb 7, 2019 By: Summer Design Conditions 43 OF Outside db 70 OF Inside db 27 OF Design TD Daily range Relative humidity Moisture difference Heating Summary Structure 26504 Btuh Ducts 5655 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 32159 Stuh Method Construction quality Fireplaces Infiltration Simplified Tight 0 Heating Cooling Area (ft2) 2283 2283 Volume (its) 23189 23189 Air changes/hour 0.11 0.06 Equiv. AVF (cfm) 43 23 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 8.6 kW 29480 Btuh 17 OF 1560 cfm 0.048 cfm/Btuh 0 in H2O 90 OF 72 OF 18 OF L 50 % 68 gr/Ib Sensible Cooling Equipment Load Sizing Structure 27078 Btuh Ducts 6991 Btuh Central vent (0 cfm) 0 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 32366 Btuh Latent Cooling Equipment Load Sizing Structure 10870 Btuh Ducts 2280 Btuh Central vent (0 cfm) 0 Btuh Equipment latent load 13150 Btuh Equipment total load 45516 Btuh Req. total capacity at 0.70 SHR 3.9 ton Cooling Equipment Summary Make Carrier Trade 16 SEER PURON AC Cond CA16NA048""A Coil FV4CNB006 AHRI ref 4585139 Efficiency 14.0 EER, 16 SEER Sensible cooling 32550 Btuh Latent cooling 13950 Btuh Total cooling 46500 Btuh Actual air flow 1550 cfm Air flow factor 0.045 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.72 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. Wtl t1tSOTt' 2019-Feb-0717:16:53 g RlghtSuite® Universal 201212.1.05 RSU02818 Pagel 14aMCAUsersVasonTocuments\Wrightsoft HVACWIW-279 AVALON.rup Calc=MJ8 Front Door faces:N GHO HOMES MW-279 3304 BENT PINE DRIVE FORT FIEPOE, FL 34951