Loading...
HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY: DATE FILED: 1VV5 �A REVISION FEE: LOCATION/SITE SCANNED BY St. Lucie County FILE COPY Y"pltc� PERMIT# RECEIPT # Wiqli PLANNING & DEVELOPMENT V' d BUILDING & CODE REGULATION IV RECEIVED 2300 VIRGINIA AVENUE FORT PIERCE,FL34982.5652 JUL 5 ?019 (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS "f1e county, Permitting PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT f CONTRACTOR INFORMATION: STATE of FL REG./CERT. M CBC051145 BUSINESS NAME: GRBK GHO HOMES LLC QUALIFIERS NAME: WILLIAM HANDLER ADDRESS: 590 NW MERCANTILE PLACE CITY: PORT ST LUCIE STATE: FL PHONE (DAYTIME): 772-873-1711 OWNER/BUILDER INFORMATION: N7t1v1B: GRBK GH MEADOWOOD LLC CITY: PORT ST LUCIE PHONE (DAYTIME: 772-873-1711 STATE: FL ARCHITECT/ENGINEER INFORMATION: ST. LUCIE CO CERT. #: _ ZIP: 34986 FAX: 561-688-0909 ZIP: 34986 FAX: 561-688-0909 NAME: NUELLE ENGINEERING ADDRESS: 11634 SW ROWENAST CITY: PORT ST LUCIE STATE: FL ZIP: 34987 PHONE (DAYTIME): 561-629-6975 FAX: SLCCC: 9123109 Revised 06130117 Planning & Development Services Dep Building & Code Regulations Divis 2300 Virginia Avenue, Fort Pierce, FL 34982 — Certification for Design Load ProjectYName: Project Address: ':�'.3 O /1703' �6�%-74/ LOOPY `5 CEIVED 46JUL 1 Lucie Cou .ei0M. ,. Permit#: / / (/� ��%_�o Occupancy Type: J� itionType: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. " Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida 2017 Building Code Fifth Edition with 20 N/A Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _ IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph X ASD _LRFD End Zone Width: 6 ft 5. Mean Roof Height 16 ft Roof Pitch: 6 :12 Parapet: NSA ft 6. Components & Cladding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings): Zone 1: +20.0.31.3 Zone 2: +20.0, 55.3 Zone 3: +20.0' 31'7 Zone 4: +34.7,-37.6 Zone 5:+34'1• -46'5 Garage: +2e.5; 34.3 7. Design Loads: Floor: 100 PSF Roof/Dead: 12 PSF Roof/Live: 30 Balcony: NIA PSF Dock: N/A PSF Deck: NIA PSF Stairs: NSA PSF Fence: N/A PSF Railings: NSA PSF B. Were Shear Walls Considered For Structure? —Yes x Not Applicable Explain Why Not: Aspect Ratio < 4:1 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2500 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie County. I also certify that structural elements depicted on these plans provide adequate resistance to the design �1 ''_ of Donald J. Nuelle 52046 Print Name Cert # & Co. Cert Auth. Nuelle Engineering �v " 11634 SW Rowena Street, P.S.L. FL 34987 t, / Company Name & Address Revised — Planning,& Development Services Department - Building & Regulations Division dsT. Luc Product Review Affidavit Building Permit # 1 L 6 3 Owners Name, bA G ,e— L UC • Applicant: nl Product moomo Opening Design Pressures Product Rated Design Pressure Manufacturer Model Number Product Approval Number Glass Type Method of Attachment Windows +31.9/ -34.8 +60/-70 MI WINDOWS FL 17499.5 R5 NONIMPUT 3/16" TAPCONS W/ 1-114" MIN. EMBED eJ&VIC Mullions 37.7 +/-54 MI WINDOWS FL 15353 NON IMPACT 1/4" TAPCONS W/ 1-1/4" MIN. Elbcn Fixed Glass +33.5 / -36.3 +/- 60 MI WINDOWS FL 15349.1-R11 NONIMPACT 3/16" TAPCONS W/ 1-1/4" MIN. EMBED 9PA., /C Block Glass Skylights Slldin Glass Doors +28.5 / -31.3 +/-55 MI WINDOWS 12080 FL 22401.1 NONIMPFCT 3/16" TAPCONS W/ 1-1/4" EMBED @ /C SwIng Type Doors +31.9 /-34.8 +/-50 THERMATRU 2680 FL-7630.1 NONIMPACT 1/4" TAPCONS W/ 1-1/4" MIN. EM French Doors Gars a Doom +28.5 / -34.8 +39.2 / -43.7 WAYNE DALTON 9100 FL-9174.10 R12 N/A 5/16" x 1-5/8" LAG SCREW EA. BRA - Hurrieane Protection 37.7 +49.0 / -56.0 men wxeeronuP eeMA 16293.1 N/A 1/4"-204/4" S.S. KNURLED STUDS 12-1/2" O.C. TOP & BTM Roof Ventilation Roofing Material _83.4 PSF - 172 PSF eA"""°°""°P"°°""" BELAIRCONO.TILE NOANO.17-0822.13 N/A (2) 10d RING SHANK NAILS Revised I _ I have reviewedlthe above components or cladding and I have approved their a in thi structure. It e products provide adequat esistan to the wind loads and forces specified by current code provisions. Name: Nuelle Engineering Signature: e Design Prof: Donald J. Nuelle Cert. No. 5204 Date: 7/9/19