Loading...
HomeMy WebLinkAboutSOLAR PLANSA SOLAR PV SYSTEM IMPROVEMENT FOR: SCHULMAN RESIDENCE [MAR 2 9 2019 t, Luele County, Pem, SOLAR IMPROVEMENT CONSTRUCTION DOCUMENTS FOR THE EXISTING RESIDENTIAL GRID TIED ELECTRICAL VICINITY MAP SYSTEM INDEX SHEET DRAWING NAME CV COVERSHEET SLR1 SOLAR SYSTEM EQUIPMENT LOCATION PLAN PVR-SS ROOF ATTACHMENT DETAIL - SOLAR ELECTRIC SLR2 ELECTRICAL 3-LINE DIAGRAM WITH CALCULATIONS -------- APPENDIX-------- HB1021 REVISION + FLASEIA LETTER HELIENE 30OW MODULE DATA SHEET APSYSTEMS YC600 MICROINVERTER DATA SHEET ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE %: ELEL DATE: LL, PLUMB: DATE: MECH: DATE: F61 1= f%npV 0 Y 0 0 w J 0 Q� O r` M H [N K W LL W h � �• a J V w g 0 00 In LL 1 DATE 03/22/2019 DRAWNBY: JAT CHKD BY: JAT REG NO. # 29127 SCALE AS NOTED DRAWING 4 \\\, l' .V I I I / MAR 2 2 2019 a�=s .0 yNjsd[ gjEw HELIENE 60M 30OW MODULE TYP. APPROXIMATE LOCATION OF L-FOOT PENETRATION TO 2'-0" SYP TRUSS. FLASH PER 2017 FBC. SEE SHEET PVR-SS FOR DETAILS. IRONRIDGE XR100 SOLAR Q RAIL TYP 2 PLCS PER MODULE ARRAY ROOFTC P JUNCTION BOX APPROXIMATE LOCATION FOR WIRE TRANSITION. SEE SHEET SLR2 WIN ZONE 3 LOCATION TYP. SEE SHEET PVR-SS FOR WZ3 REQUIREMENTS 0 APPROXIMATE LOCATION OF MAIN DISTRIBUTION PANEL LOCATED INSIDE GARAGE. 11 -3 MATERIALS REQUIRED: (18) HELIENE 60M 30OW MODULES W/ (9) APSYSTEMS YC600 (5) IRONRIDGE MICROINVERTER MOUNTING KITS (NOTE: EACH KIT COMES WITH 2 BOLTS) (4) 14' XR100 RAIL (4) 17' XR100 RAIL (4) XR-1 00 INTERNAL BONDED SPLICE KITS (2) GROUNDING LUGS FOR ARRAY CONNECTIONS OF #6 BARE COPPER 140) WIRE MANAGEMENT CLIPS (38) IRONRIDGE L-FOOT WITH LAG SCREW (8 IRONRIDGE END SLEEVES (8) IRONRIDGE END CAPS FOR RAILS (40) IRONRIDGE GROUNDING UFO CLAMPS (2) APSYSTEMS TRUNK CABLE END CAP (9) APSYSTEMS TRUNK CABLE APSYSTEMS Y-CONN CAPS (AS NEEDED) (1) NEMA 3R RATED ROOF MOUNTED JUNCTION BOXES DISCLAIMER: MATERIALS REQUIRED LIST FOR CONCEPTUAL USE ONLY THE INTENT IS TO AID CONTRACTOR FOR ORDERING REQUIRED MATERIALS FOR THE PROJECT. CONTRACTOR RESPONSIBLE TO VERIFY PRIOR TO SOLAR EQUIPMENT ORDERING. DATE 03/22/2019 DRAWN BY. JAT CHKD BY: JAT REC. NO. # 29127 SCALE AS NOTED ROOF LAYOUT NOTE: SOLAR PANEL LAYOUT IS CONCEPTUAL, BUT AS PROVIDED, CONFORMS WITH THE REQUIREMENTS SET IN SHEET PVR-SS FOR SPECIFIED ADDRESS. CONTRACTOR MAY ADJUST PANEL LOCATION, BUT SHALL RESIDENTIAL ROOF LAYOUT - WIND ZONES - PV MODULE LAYOUT AND EQUIPMENT LOCATION PLAN CONFORM TO THE REQUIREMENTS ON SHEET PVR-SS. SOLID AREAS ON CORNERS OF ROOF ARE WIND ZONE 3 AREAS. SCALE: N.T.S. LOADS FOR BUILDING AND OTHER STRUCTURES. 2. BOLT DIAMETER AND EMBEDMENT LENGTHS ARE DESIGNED PER 2017 FLORIDA BUILDING CODE (6TH EDITION) REQUIREMENTS. ALL BOLT CAPACITIES ARE BASED ON A SOUTHER YELLOW PINE (SYP) RESIDENTIAL WOOD ROOF TRUSS AS EMBEDMENT MATERIAL 3. ALL WIND DESIGN CRITERIA AND PARAMETERS ARE FOR HIP AND GABLE RESIENTIAL ROOFS, CONSIDERING FROM A 7" TO A MAXIMUM 27° (2/12 TO A MAXIMUM 6/12 PITCH) ROOF IN SCHEDULE. EXISTING RESIDENTIAL ROOF SHALL NOT EXCEED 30'-0"MEAN ROOF HEIGHT. 4. ROOF SEALANTS SHALL CONFORM TO ASTM C920 AND ASTM 6511, AND IS THE RESPONSIBILITY OF THE CONTRACTOR TO PILOT FILL ALL HOLES. S. THIS SHEET REFLECTS STRUCTURAL CONNECTIONS ONLY. REFER TO MANUFACTURER MANUAL FOR ALL ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND SOLAR SPECS. 6. ALL ALUMINUM COMPONENTS SHALL BE ANODIZED ALUMINUM 6105-T5 UNLESS OTHERWISE NOTED. 7. LAG BOLTS SHALL BE ASTM A276 STAINLESS STEEL UNLESS OTHERWISE NOTED. B. ALL 39" X 65" PV MODULES MAY BE INSTALLED PER THIS STRUCTURAL CONNECTION DRAWING. 9. ALL SOLAR RAIUNG AND MODULES SHALL BE INSTALLED PER MANUFACTURER INSTRUCTIONS. 10. CONTRACTOR SHALL ENSURE ALL ROOF PENETRATIONS TO BE INSTALLED AND SEALED PER 2017 FLORIDA RESIDENTIAL CODE (6TH EDITION) OR LOCAL GOVERNING CODE ULTIMATE WIND ZONE I MAX WIND ZONE 2 MAX WIND ZONE 3 MAX EMBED. WIND SPEED SPAN,MAX SPAN, MAX SPAN, MAX DEPTH Vm,(MPH) CANTILEVER CANTILEVER CANTILEVER REQ. 160 4'-0" O.C., 1'-7" O.C. I 4'-0" O.C.,1'.7" O.C. 2'-0" O.C., 9" O.C. 3" - SCHEDULE REFLECTS COMPONENTS AND CLADDING (C&C) NOMINAL WIND PRESSURES WITH EXPOSURE "B", RISK CATEGORY 11, ENCLOSED BUILDING AND h <60V PER ASCE 7-10 "MINIMUM DESIGN LOADS FOR BUILDING AND OTHER STRUCTURES" AND 2017 F.R.C. • LAG BOLT DEPTH REQUIRED IN WOOD MEMBER EXCLUDES ANY ROOF DECKING THICKNESS. 11. a DIMENSION DEFINED PER ASCE 7-10 SHALL BE 4 FT REGARDLESS AS PER 2017 FLORIDA RESIDENTIAL CODE 6TH EDITION GABLE END BUILDING 1 HIP END BUILDING ROOF ROOF WIND AREA ZONES WIND AREA ZONES 01 TYPICAL PHOTOVOLTAInRRAY PITCHED ROOF LAYOUT - WIND ZONES - SCHEDULE - PLAN SCALE: NONE 39" X 65" PHOTOVOLTAIC ALUM. SOLAR RAIL TYP 2 PLCS MODULE TYP. \ , ARRAY. TRS 7\ C TRS , ri TRS TRS L1MAX CANT. SEE SCH ASPHALT SHINGLES ALUM L-FOOT eBIA ST STL LAG BOLT /METAL 5V ROOF TYP, SCH FOR MAX SPAN REQ. TYPICAL PHOTOVOLTAIC MODULE ARRAY PLAN SCALE: "=V-0" S.Y.P. 2X4 LOCATE BETWEEN TRUSSES AND NAIL WITH 2.16D NAIL PATTERN AT EACH END TO WOOD TRUSS 2X PT S.Y.P. WOOD UNISTRUT CONT. AL SHINGLES/ METAL 5V ROOFING TYP, TEEL ALL -THIRD OD W/ NUT - WASHERS - LOCTITE ALL NUTS TYP. ALL CONNECTIONS OPTIONAL SPANNER CONNECTION DETAILS SCALE: 1 3'=V-0" 12" ALUMINUM INTERNAL -- - .. SPLICE BAR USE WHEN ___ ___;___ ==c _ -- SPLICEATMID-SPAN W/ ----- _===e. :=-e °____ -T = -- 4 #12.14X51, ST STL SELF TAPPING SCREWS TYP IRONRIDGE XR1000 OR XRI00 _ #12,14X8" ST STL SELF TAPPING ALUM. SOLAR RAIL TYP SCREW TYP 4 PLCS PER BEAM SPLICE TYPICAL SOLAR RAIL BEAM SPLICE DETAIL SCALE: 1 l'"=1' 0" 2 PLCS. PER SIDE OF MODULE AND BE CONNECTED < 25% OF MODULE LENGTH. USE ANTI -SEIZE AND TIGHTEN TO TORQUE PER MANUF. INSTRUCTIONS REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH a, LABELED "X" IN THIS DETAIL. b'CLR' ALUMINUM L-FOOT TYP EVERY ROOF PENETRATION 16 HEX CAP ST STL BOLT AND ST STL SERRATED FLANGE -NUT SEE TYP. P W q' END -CLAM - PHOTOVOLTAIC * '- = ' 20 HEX CAP ST 3TL MODULE TYP. _..�_ '�_ BOLT AND ST STL ASPHALT SERRATED -. SHINGLES / FLANGE -NUT TYP. IRONRIDGE XR1000 -��_' =-� METAL 5V END -CLAMP SIZE OR XR100 ALUM. WOOD ROOFING TYP. VARIES. SOLAR RAIL TYP. -- SHEATHING 3" ST STL LAG BOLT. SEE WOOD ROOF SCH FOR EMBED DEPTH TRUSS TYP. REQ. TYP EACH L-FOOT TYPICAL PV SOLAR RAIL END CONNECTION DETAIL SCALE: 1 2"=1' 0" REFER TO SCHEDULE FOR REQUIRED EMBEDMENT DEPTH LABELED "X" IN THIS DETAIL ALUMINUM L-FO( TYP EVERY ROOF PENETRATION 8" -16 HEX CAP ST STL BI AND ST STL SERRATED FLANGE NUT TYP. \—CENTER-CLAMP WITH =r - 4" - 20 HEX CAP ST PHOTOVOLTAIC %i-- ' STL BOLT AND (1( ST MODULE TYP. ---- ":`i'" STL SERRATED �� ecounlr FLANGENUTTYP. _,Z IRONRIDGE XR1000 OR XR100 ALUM. SOLAR RAIL TYP. WOOD SHEATHING TYPICAL PV SOLAR SCALE: 1 1"=1' 0" SHINGLES —FRONT SIDE BEAM SINCE METAL 5V LOCATION. SEE TYP_�ETA -WOOD ROOFING e" ST STL LAG BOLT. SEE SCE ROOF TYP' FOR EMBED. DEPTH REQ. TYP,= TRUSS TYP. EACH L-FOOT RAIL MID CONNECTION DETAIL O Om 3V x �LL o �w 0 �zwm � ON NN �<',z oz LL �O <La <<�G Paz G> -< N 6No �H au a� DATE: 03-22-2019 DRAWN BY: JAi CHKD BY: JAT RECORD #: 29127 SCALE I AS NOTED MAR 2 2 2019 10WERTABLE: SYSTEM SYSTEM DC -SIDE A B C 1STBRNCH C 2ND BRNC AC -SIDE 4PVMODULE 1 1 5 4 INVERTER MANUF HELIENE APSYSTEMSYC600 MODEL 60M 548 W 2740 W 2192 W RATED POWER POWER 300Wp-dc 600 W 3000 W -- 2400 W MAX POWER VOC 39.83 VDC 240 VAC 240 VAC 240 VAC VOLTAGE ISC 9.59A 2.28A 11AA 9.12A NOM CURRENT VMP 33.14 VDC IMP 19.13 AMP 60 HZ 60 HZ 60 HZ FREQUENCY It STC: CELL TEMPERATURE (0). 25' C, SPECTRUM AM1.5, IRRADIANCE Ca) 1000 W/M2 SYSTEM A IIojMODUu3/ IBINYERRRS BRANCH CROUT TERMINATOR CAP INSTALLED ON END OF TC-ER CABLE SYSTEM CONTINUOUS #6 AWG CU CONDUCTOR BONDING SOLAR RAIL AND MODULES W/ WEEB LUGS AND MODULES SHALL BE BONDED TO RAIL WITH WEEB WASHERS, INTEGRATED GROUNDING MID CLAMP OR EQUIVALENT TO SIMPLIFY INSTALLATION. MICROINVERTERS CONTAIN INTEGRATED EQUIPMENT GROUNDING. SYSTEM B IBj MODULES/(QPW RIERSIN BRANCHCIRCUI] TERMINATOR CAP INSTALLED ON END OF TC-ER CABLE SYSTEM CONTINUOUS #6 AWG CU CONDUCTOR BONDING SOLAR RAIL AND MODULES W/ WEEB LUGS AND MODULES SHALL BE BONDED TO RAIL WITH WEEB WASHERS, INTEGRATED GROUNDING MID CLAMP OR EQUIVALENT TO SIMPLIFY INSTALLATION. MICROINVERTERS CONTAIN INTEGRATED EQUIPMENT GROUNDING. CABLE (1 n Y�I/ CABLE SYSTEM TC-ER #12 AWG CU 90 RATED INSULATED CABLE OBTAIN ALL PERMITS AND APPROVALS FROM GOVERNING AGENCIES PRIOR TO THE COMMENCEMENT OF WORK ALABEL DEVICE PER NEC 690.14(C)(2), AND SECURE PER NEC 690.7(D). EQUIPMENT SHALL BE INSTALLED PER THE 2014 NATIONAL ELECTRICAL 2 CODE (NEC), ALL APPLICABLE OR GOVERNING CODES, MANUFACTURER 6 LABEL BREAKER PER NEC 690.54, 705.12(D) AND 705.10. REQUIREMENTS OF AND PER THE GOVERNING UTILITY COMPANY . _ LISTING AGENT NAME AND NUMBER SHALL BE INDICATED PER NEC PV BACKFEED CURRENT PLUS MAIN BREAKER RATING MUST BE LESS THAN 110.3(B). AP SYSTEMS MICROINVERTERS ARE RAPID SHUTDOWN 7 OR EQUAL TO 120%OF MAIN SERVICE BUS RATING AND BREAKERS MUST COMPLIANT PER NEC 690.12 BE MOUNTED AT OPPOSITE END OF MAIN BREAKER PER NEC 705.12(D). CONDUCTOR WIRE SIZES SHOWN BASED SOLELY ON AMPACITY REQUIREMENTS. TO AVOID ANY NUISANCE FAULTS, It 15 RECOMMENDED TO SIZEENT AN INCREASE IN AC VOLTAGE LEVEL AND Q NOT USED CONDUCTOR FOR A TOTAL VOLTAGE DROP OF 2% OR LESS PER INV. MANUFACTURER. C ' 4 ,- JUNCTION BOX = NEMA 31? ENCLOSURE Ll t-1 INVERTER OUTPUT CIRCUIT CABLE OUTDOOR / INDOOR CONDITIONS (3) # 10 AWG CU, INSULATION: THHN/THWN-2 (1) # 10 AWG CU, INSULATION: THHN/THWN-2 GROUND CONDUCTOR CONDUIT SIZE: "' MINIMUM ATTIC SPACE / WALL INTERIOR RUN ONLY WIRING OPTION (3)#10 AWG W/(1)#10 GROUND NM ROMEX CABLE, OF CABLE OR EQUIVALENT AP SYST S INSULATED BUS CABLE AP YC600 MICROINVERTER TYP. #6 AWG SOLID CU GROUND TYP. Q Y G NEW AC Q 150 m #6 AWG SOLID CU GROUND TYP. NOTE•. DISCONNECT IF MAR EXISTING 150 w MAXIMUM OF 7INVERTERS PER REQ BY UTILITY BR ER AMP MAIN A g TC-ER BRANCH CIRCUIT PER J 3 CABLE SYSTEM MANUFACTURER 4 15A/2P (MIN MUM) SERVICE PANEL t- RECOMMENDATIONS. Ll (MINIMUM- LL VERIFY IN FIELD) O n0�, LC W LL K y � a� H U F o a , - -, O De O O TC-ER #12 AWG CU 90 C AP SYSTFJ IS INSULATED BUS CABLE RATED INSULATED CABLE Tt LI TO EXISTING DATE 03/22/2019 3 5 L2 GROUNDING DRAWN BY: lAT ELECTRODE CHKD BY: JAT AP YC600 MICROINVERTER TYP. 4 6 AWG SOLID CU GROUND TYP. N G RK.NO.# 29127 #6 AWG SOLID CU GROUND TYP. SCALE AS NOTED NOTE: ALL CONDUCTORS THIS SHEET SHALL BE COPPER UNLESS OTHERWISE NOTED. MAIN PV SYSTEM CAUTION WARNING ENEC2014LABELINGREQUIREMENTS DUAL POWER SOURCE DISCONNECT SOLAR ELECTRIC SYSTEM SECOND SOURCE ISPVSYSTEPPERNEC690.15&NEC690.13IB)-PROVIDEAT CONNECTED LABELPFRNEC70S.12(Dj(3)&NEC690.64 �� SMAIN SERVICE PANELORNEWSEANCE PANEL F00. IABELPERNEC690d5&NEC 690.13IBL PROVIDEAT PRDVIDEAT MAIN SE0.NCE PANELORTAPJ�lIL OF 4 , SOLAR PV FOR SUPPLY SIDE CONNECTION NEW OR E%IMNG SUB PANEL OR SERVICE PANEL LOCATION I WARNING PHOTOVOLTAIC ACDISCONNER CAUTION ELECTRIC SHOCK HAZARD. DO NOT TOUCH MA%IMUMACOPERATINGCURRENT: 20.52A WARNING PHOTOVOLTAIC SYSTEM -' TERMINALS. TERMINALS ON BOTH THE LINE WARNING MA%IMUMACOPERATINGVOLTAGE: 24DV EQUIPPED WITH RAPID PHOTOVOLTAIC SYSTEM QR%IT' A AND LOAD SIDES MAY BE ENERGIZED IN THE INVERTER OUTPUT CONNECTION - DO NOT DEDICATED SOLAR PANEL DO SHUTDOWN IS BACKFED % SFN. OPEN POSITION IPLRx NSERVCF.'R Vl.. L / RELOCATE THIS OVERCURRENT DEVICE°smxxLa�mwxumiavu,wxLwssm�avu,ar°n NOT CONNECT ANY LOADS IABELPERNEC69D56LCj-PRRAPIDTNEW SUB IABELPERNEVF(V12(DR3GSNEC TROOPER NEC 69l.]]IEI-PR°NDE qT MAIHSERN[E PANN. IABELPERNEC]�13I0)D1136I-PPOMDf AT (MIN $FRNRPANEl 5°IARw VgppuG¢:EI IABELPER NEC lll1.21-PRONDEATNEW SUB PANFL00.5ERVICE PANELfOR WVIDSNUTDOWN PROVIDE ATNEW ORE%ISTNG SUB PANG RYpp'•• PANEL Oft SERNCE PANEL (IF REQUIRED) COMPUAMSYSTEMS. SERVICE PANEL 4 '11)}RlYX.'IORRE6,Pf: MAR 2 2 2019