HomeMy WebLinkAboutF A E CONSULTING PAPERWORKFebruary 02, 2011
Planning & Development Services
Building 7 Code Regulations Division
2300 Virginia Ave.
Fort Pierce, Florida 34982
Attn: Mr. Ken Arnold
RE: Permit # 1012-0226
Navy Seal Museum
Dear Mr. Arnold,
RMN
CONSULTING
SCANNED
BY
St. Lucie County
Below please find our response to your building department comment for Navy Seal Museum, permit number
1012-0226.
1) The jurisdiction in the project summary (energy codes) must be stated as "St. Lucie County,
Florida" (66100).
FAE Consulting's response: Please refer to revised energy calculation document.
Should you have any questions, please contact us.
Sincerely,
Harold R. Tussler, PE
FAE Consulting
1640 N.W. 2nd Avenue I Boca Raton, FL 33432 1 Phone 561.391.9292 1 Fax 561.391.9898
tip
PROJECT #1 ❑396
NATIONAL NAVY UOT-SEAL MUSEUM
CONTENTS:
REVISED ENERGY CALCULATION
DATE:
❑ 2/❑2/ 1 1
PREPARED BY:
m m
CONSULTING
1 6413 NW 2ND AVE
BOLA RATON, FL 33432
Florida Energy Efficiency. Code For -Building Construction
Florida Department of CommunityAffai�s
-Energy-Gauge Summit® Fla/Com-2008'Ff ective:-,March 1, 2009 Form'400A-2008,
- Method A: Whole Building,Performance:Method for.Commercial Buildings,
,t
PROJECT SUMMARY
Short Dese: Navy Seal Museum Description: ........
Owner: ....
Addressl: 3300 North Highway AIA City: Fort Pierce
Address2: State: Fl
Zip:
34949
Type:
Museum
Class:
New Finished building
Jurisdiction:
FORT PIERCE, ST LUCIE COUNTY, FL (661100)
Conditioned Area:
8400 SF
Conditioned & UnConditioned Area:
8400 SF
No of Stories:
1
Area entered from Plans
8400 SF
Permit No:
0
Max Tonnage
5
If different, write in:
a
EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009
2/2/2011 Page 1 of 9
Component Design Criteria Result
Gross Energy Cost (in $) 5,955.0 8,529.0 PASSED
LIGHTING CONTROLS
EXTERNAL LIGHTING
HVAC SYSTEM
PLANT
WATER HEATING SYSTEMS
PIPING SYSTEMS
Met all required compliance from Check List?
PASSES
PASSES
PASSES
None Entered
PASSES
None Entered
Yes/No/NA
IMPORTANT MESSAGE
Info 5009 -- — --An input report of this design building must be submitted along with this
Compliance Report
EnergyGauge Summit@ Fla/Com-2008. Effective: March 1, 2009
2/2/2011
Page 2 of 9
CERTIFICATIONS
I hereby certify that the plans and specifications covered by this calculation are in compliance with the
Florida Energy Code
Prepared By: Harold R. Tussler
Building Official:
Date:
l_�1 Date:
I certify that this building is in complianccwith the FLorida Energy Efficiency Code
Owner Agent:
Date:
If Required by Florida law, I hereby certify (') that the system design is in compliance with the FLorida
Energy Efficiency Code
Architect:
Electrical Designer: Harold R. Tussler
Lighting Designer: Harold R. Tussler
Mechanical Designer: Harold R. Tussler
Reg No:
Reg No: 19315
Reg No: 19315
Reg No: 19315
Plumbing Designer: Harold R. Tussler Reg No: 19315
(') Signature is required where Florida Law requires design to be performed by registered design
professionals.
EnergyGauge Summit@ Fla/Com-2008. Effective: March 1, 2009
2/2/20l I
Page 3 of 9
Project: Navy Seal Museum
Title:........
Type: Museum
(WEA File: FL ST LUCIE
Total
EL ECTRICITY(MBtulkWhl$)
AREA LIGHTS
Building End Uses
1) Proposed
2) Baseline
381.30
635.40
$5,955
$10,035
381.30
635.40
111724
186170
$5,955
$10,035
68.60
89.50
20090
26214
$1,071
$1,413
MISC EQUIPMT
126.00
126.00
36922
36922
$1,968
$1,990
PUMPS & MISC
0.10
0.10
22
23
$1
$1
SPACE COOL
141.70
279.00
41520
81754
$2,213
$4,407
SPACE HEAT
5.00
11.90
1474
3497
$79
$188
VENT FANS
39.90
128.90
11696
37760
$623
$2,035
Passing requires Proposed Building cost to be at most 85%
PASSES
if Baseline cost. This Proposed Building is at 59.3%
EnergyGauge Summit@ Fla/Com-2008. Effective: March 1, 2009
2/2/2011 Page 4 of 9
Project: Navy Seal Museum
t itle:........
Type. Museum
(WEA File: FL ST_LUCIE_CO INTL.tm3)
External Lighting Compliance
Description Category Tradable? Allowance Area or Length ELPA CLP
(W/Unit) or No. of Units (W) (W)
(Sgft orft)
Ext Light I Walk way less than 10 feet wide Yes 1.00 1,826.0 1,826 1,500
Ext Light 2 Main entries Yes 30.00 144.0 4,320 200
Ext Light 3 Walk way less than 10 feet wide Yes 1.00 335.0 335 200
Tradable Surfaces: 1900 (W) Allowance for Tradable: 6805.05 (W) PASSES
All External Lighting: 1900 (W)
Complicance check includes a 5% excess allowance of 324.05(W)
Project: Navy Seal Museum
Title:........
Type: Museum
(WEA File: FL ST LUCIE_CO tNTL.tm3)
Lighting Controls Compliance
Acronym Ashrae Description Area Design Min Compli-
ID (sq.ft) CP CP ance
Gallery#1 17,001 General Exhibition (Museum) 4,200 2 2 PASSES
Gallery #2 17,001 General Exhibition (Museum) 2,600 2 2 PASSES
OffBathrm 16 Office -Open Plan 1,600 2 1 PASSES
PASSES
EnergyGauge SummitO Fla/Com-2008. Effective: March 1, 2009
2/2/2011 Page 5 of 9
Project: Navy Seal Museum
Title:........
Type: Museum
(WEA File: FL_ST_LUCIE_CO_INTL.tm3)
System Report Compliance
AHU-1 Split System
Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr
l
Component
Category
Capacity Design Eff Design IPLV
Comp-
Eff Criteria IPLV Criteria
liance
Cooling System
Air Conditioners Air Cooled
16.00 12.23 8.00
PASSES
Split System < 65000 Btu/h
Cooling Capacity
Heating System
Electric Furnace
1.00 1.00
PASSES
Air Handling
Air Handler (Supply) -
0.35 0.90
PASSES
System -Supply
Constant Volume
Air Distribution
ADS System
6.00 3.50
PASSES
System
AHU-2 Split System
Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr
1
Component
Category
Capacity Design Eff Design IPLV
Comp-
Eff Criteria IPLV Criteria
liance
Cooling System
Air Conditioners Air Cooled
16.00 12.23 8.00
PASSES
Split System < 65000 Btu/h
Cooling Capacity
Heating System
Electric Furnace
1.00 I.00
PASSES
Air Handling
Air Handler (Supply) -
0.35 0.90
PASSES
System -Supply
Constant Volume
Air Distribution
ADS System
6.00 3.50
PASSES
System
AHU-3 Split System
Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr
1
Component
Category
Capacity Design Eff Design IPLV
Comp-
Eff Criteria IPLV Criteria
fiance
Cooling System
Air Conditioners Air Cooled
16.00 12.23 8.00
PASSES
Split System < 65000 Btu/h
Cooling Capacity
Heating System
Electric Furnace
1.00 1.00
PASSES
Air Handling
Air Handler (Supply) -
0.35 0.90
PASSES
System -Supply
Constant Volume
Air Distribution
ADS System
6.00 3.50
PASSES
System
EnergyGauge Summit® Fla/Com-2008. Effective: March 1, 2009
2/2/2011 Page 6 of 9
AHU-4 Split System
Constant Volume Air Cooled No. of Units
Split System < 65000 Btu/hr
1
Component
Category
Capacity
Design
Eff Design IPLV
Comp-
Eff
Criteria IPLV Criteria
liance
Cooling System
Air Conditioners Air Cooled
16.00
12.23 8.00
PASSES
Split System < 65000 Btu/h
_
Cooling Capacity
Heating System
Electric Furnace
1.00
1.00
PASSES
Air Handling
Air Handler (Supply) -
0.35
0.90
PASSES
System -Supply
Constant Volume
Air Distribution
ADS System
6.00
3.50
PASSES
System
AHU-5 Split System
Constant Volume Packaged No. of Units
System-902
1
Component
Category
Capacity
Design
Eff Design IPLV
Comp-
Eff
Criteria IPLV Criteria
liance
Cooling System
Air Conditioners Air Cooled
16.00
12.23 8.00
PASSES
< 65000 Btu/h Cooling
Capacity
Heating System
Electric Furnace
1.00
1.00
PASSES
Air Handling
Air Handler (Supply) -
0.35
0.90
PASSES
System -Supply
Constant Volume
Air Distribution
ADS System
6.00
3.50
PASSES
System
PASSES
Plant Compliance
Description
Installed Size Design
Min
Design
Min Category
Comp
No Eff
Eff
IPLV
IPLV
liance
None
EnergyGauge SummitO Fla/Com-2008. Effective: March 1, 2009
2/2/2011 Page 7 of 9
Project: Navy Seal Museum
Title:........
Type: Museum
(WEAFile: FL_ST_LUCIE_CO_INTL.tm3)
Water Heater Compliance
D
Description Type
Design Min
Category
Eff Eff
Design Max Comp
Loss Loss liance
Water Heater I Electric water heater <= 12 [kWJ 0.90 0.88
PASSES
PASSES
Piping System Compliance
Category
Pipe Dia Is Operating Ins Cond Ins Req Ins Compliance
[inches] Runout? Temp [Btu-in/hr Thick [inl Thick [in]
[FJ SF.FJ
None
EnergyGauge Summit® Fla/Com•2008. Effective: March 1, 2009
2/2/2011 Page 8 of 9
Navy Seal Museum
Museum
. File: FL_ST_LUCIE_CO_INTL.tm3)
Category
Report
Operations Manual
Windows & Doors
Section
13-101
13-102.1,
13-410, 13-413
13406.AB.1.1
Joints/Cracks 13406.AB.1.2
Dropped Ceiling Cavity 13406.AB.3
System
Reheat
HVAC Efficiency
HVAC Controls
Ventilation Controls
ADS
HVAC Ducts
Balancing
Piping Insulation
Water Heaters
Swimming Pools
Hot Water Pipe
Insulation
Water Fixtures
Motors
Lighting Controls
13-407
Other Required Compliance
Requirement (write N/A in box if not applicable)
Input Report Print -Out from EnergyGauge FlaCom attached
Operations manual provided to owner
Glazed swinging entrance & revolving doors: max. 1.0 cfm/ft2; all
other products: 0.4 cfm/ft2
To be caulked, gasketed, weather-stripped or otherwise sealed
Vented: seal & insulated ceiling. Unvented seal & insulate roof &
side walls
HVAC Load sizing has been performed
13-407.13 Electric resistance reheat prohibited
13-407, 13408 Minimum efficiences: Cooling Tables 13407.AB.3.2.IA-D;
Heating Tables 13407.AB.3.2.IB, 13-407.AB.3.2. I D,
13408.AB.3.2.1E, 13408.AB.3.2F
13407.AB.2 Zone controls prevent reheat (exceptions); simultaneous heating
and cooling in each zone; combined HAC deadband of at least 5°F
(exceptions)
13-409.AB.3 Motorized dampers reqd, except gravity dampers OK in: 1) exhaust
systems and 2) systems with design outside air intake or exhaust
capacity:5300 cfm
13-410 Duct sizing and Design have been performed
13410.AB Air ducts, fittings, mechanical equipment & plenum chambers shall
be mechanically attached, sealed, insulated & installed per Sec.
13-410 Air Distribution Systems
13410.ABA HVAC distribution system(s) tested & balanced. Report in
construction documents
13-41 LAB In accordance with Table 13-41 LAB.2
13412.AB Performance requirements in accordance with Table 13-412.AB.3
Heat trap required
13412.AB.2.6
Cover on heated swimming pools: Time switch (exceptions);
Readily accessible on/offswitch
1341 LAB.3
Table 1341 LAB.2 for circulating systems, first 8 feet of outlet
pipe from storage tank and between inlet pipe and heat trap
13-412.AB.2.5
Shower hot water flow restricted to 2.5 gpm at 80 psi. Public
lavatory fixture how water flow 0.5 gpm max; if self -closing valve
0.25 gallon recirculating, 0.5 gallon non recirculating
13414
Motor efficiency criteria have been met
13415.AB
Automatic control required for interior lighting in buildings >5,000
s.f.; Space control; Exterior photo sensor; Tandom wiring with 1 or
3 linear fluuorescent lamps>30W
Check
EnergyGauge Summit@ Fla/Com•2008. Effective: March 1, 2009
2/2/201l Page 9 of 9
Project Name: Navy Seal Museum
Project Title: ........
Address: 3300 North Highway AlA
State: Fl
Zip: 34949
Owner:
EnergyGauge Summit® v3.22 I I
INPUT DATA REPORT
Proiect Information
Orientation: North
Building Type: Museum
Building Classification: New Finished building
No.of Stories: 1
GrossArea: 8400 SF
Zones
No Acronym Description Type
Area Multiplier
[sf]
Total Area
(sf]
1 Gallery Zone 1 CONDITIONED
8400.0 1
8400.0 ❑
Spaces
No Acronym Description Type Depth
[ft]
Width Height Multi Total Area
[it] [it] plier [sf]
Total Volume
[cf]
2/2/2011 EnergyGauge Summit® v3.22 1
In Zone: Gallery
I Gallery #1 ........
General Exhibition
70.00
60.00
12.00
1 4200.0
50400.0
❑
(Museum)
2 Gallery #2 ........
General Exhibition
74.29
35.00
12.00
1 2600.0
31200.0
El
(Museum)
3 Off/Bathrm ........
Office - Open Plan
64.00
25.00
12.00
1 1600.0
19200.0
❑
Lighting
No Type
Category
No. of
Watts per
Power
Control Type
No.of
Luminaires
Luminaire
fW]
Ctrlpts
In Zone: Gallery
In Space: Gallery #1
1 Recessed Fluorescent - General Lighting
12
240
2880
Manual On/Off
2
❑
No vent
In Space: Gallery #2
1 Recessed Fluorescent - General Lighting
8
240
1920
Manual On/Off
2
❑
No vent
In Space: OffBathrm
I Recessed Fluorescent - General Lighting
17
96
1632
Occupancy sensor without 1
No vent
Daylighting
2 Recessed Fluorescent - General Lighting
2
64
128
Occupancy sensor without I
No vent
Daylighting
Walls
No Description
Type Width H (Effec) Multi
Area DirectionConductance Heat
Dens. R-Value
[ft]
[ft] plier
[sf]
[Btu/hr.
sC F] Capacity
flb/cf] [h.sf.FBtu]
[Btu/sf.F]
In Zone: Gallery
I ......••
6"CMU with 2" 119.00
12.00 1
1428.0
North
0.0621 14.212
79.12 16.1
❑
rigid insulation in
both side
2 ........
6"CMU with 2" 119.00
12.00 1
1428.0
North
0.0621 14.212
79.12 16.1
❑
rigid insulation in
both side
2/2/2011 EuergyGauge Summit® v3.22
3 ........
6"CMU with 2"
70.59
12.00 1
847.1
North
0.0621
14.212
79.12
16.1
❑
rigid insulation in
both side
4 ........
6"CMU with 2"
70.59
12.00 1
847.1
North
0.0621
14.212
79.12
16.1
❑
rigid insulation in
both side
Windows
No Description Type
Shaded
U SHGC Vis.Tra
W
H (Effec)
Multi
Total Area
[Btu/hr sf F]
IN
[ft]
plier
[sf]
In Zone:
In Wall:
Doors
No
Description
Type
Shaded? Width H (Effec) Multi
Area
Cond.
Dens. Heat Cap.
R-Value
[ft] [ft]
plier
[sf] [Btu/hr. sf. F]
[Ib/cf] [Btu/sC F]
[h.sf.FBtu]
In Zone: Gallery
In Wall:
North Wall
1
....
Solid core flush
No
6.00 8.00
1
48.0
0.3504
0.00
0.00
2.85
❑
(2.25)
In Wall:
South Wall
1
....
Solid core flush
No
6.00 8.00
1
48.0
0.3504
0.00
0.00
2.85
❑
(2.25)
In Wall:
East Wall
1
....
Solid core flush
No
6.00 8.00
1
48.0
0.3504
0.00
0.00
2.85
(2.25)
In Wall:
West Wall
1
....
Solid core flush
No
6.00 8.00
1
48.0
0.3504
0.00
0.00
2.85
(2.25)
2/2/2011 EnergyGauge Summit® v3.22
Roofs
No Description
Type
Width
H (Effec) Multi
Area Tilt Cond. Heat Cap
Dens. R-Value
[ft]
[ft] plier
[sf] [deg] [Btu/hr. SE F] [Btu/sf. F]
[lb/cf] [h.sLF/Btu]
In Zone: Gallery
1 .............
Mtl Bldg Roof/R-19
70.59
119.00 1
8400.0 0.00 0.0492 1.34
9.49 20.3
❑
Batt
Skylights
No Description Type
U SHGC Vis.Trans W H (Effec) Multiplier
Area Total Area
[Btu/hrAF]
Vt] [ft]
[Sf] [Sf]
In Zone:
In Roof:
Floors
No Description
Type
Width
H (Effec) Multi
Area Cond. Heat Cap. Dens.
R-Value
[ft]
[ft] plier
fsf] [Btu/hr. sL F] [Btu/st F] [Ib/cf]
[h.sLF/Btu]
In Zone: Gallery
I ........
1 ft. soil, concrete
119.00
70.59 1
8400.0 0.2681 34.00 113.33
3.73
❑
floor, carpet and
rubber pad
Systems
ARU-1 Split System
Constant Volume Air Cooled Split No. Of Units 1
System < 65000 Btu/hr
Component Category
Capacity
Efficiency IPLV
1 Cooling System
60000.00
16.00 8.00
❑
2 Heating System
34120.00
1.00
❑
2/2/2011 EnergyGauge Summit® v3.22
3
Air Handling System -Supply
2000.00 0.35
❑
4
Air Distribution System
6.00
El
AHU-2
Split System
Constant Volume Air Cooled Split
No. Of Units 1
System < 65000 Btu/hr
Component
Category
Capacity Efficiency
IPLV
1
Cooling System
60000.00 16.00
8.00
El
2
Heating System
34120.00 1.00
❑
3
Air Handling System -Supply
2000.00 0.35
El
4
Air Distribution System
6.00
El
AHU-3
Split System
Constant Volume Air Cooled Split
No. Of Units 1
System < 65000 Btu/hr
Component
Category
Capacity Efficiency
IPLV
1
Cooling System
47550.00 16.00
8.00
❑
2
Heating System
34120.00 1.00
3
Air Handling System -Supply
1600.00 0.35
El
4
Air Distribution System
6.00
AIIU4
Split System
Constant Volume Air Cooled Split
No. Of Units 1
System < 65000 Btu/hr
Component
Category
Capacity Efficiency
IPLV
1
Cooling System
47550.00 16.00
8.00
2
Heating System
34120.00 1.00
3
Air Handling System -Supply
1600.00 0.35
4
Air Distribution System
6.00
2/2/2011 EnergyGauge Summit® v3.22
AHU-5 Split System
Constant Volume Packaged System-
-902
No. Of Units 1
Component Category
Capacity
Efficiency IPLV
1 Cooling System
2 Heating System
3 Air Handling System -Supply
4 Air Distribution System
42600.00
23884.00
1400.00
16.00 8.00
1.00
0.35
6.00
❑
❑
❑
❑
Plant
Equipment
Category Size
Inst.No Eft
1PLV
Water Heaters
W-Heater Description
CapacitlCap.Unit I/P Rt.
Efficiency
Loss
1 Electric water heater
40 [Gal] 5 [kW]
0.9000 [Ef]
[]3tu/h] ❑
Ext-Lighting
Description
Category
No. of
Watts per
Area/Len/No. of units Control Type
Wattage
Luminaires
Luminaire
[sf/ft/No]
M
1 Ext Light 1
Walk way less than 10 feet
6
250
1826.00 Astronomical Timer Coi
1500.00
❑
wide
2 Ext Light 2
Main entries
2
100
144.00 Astronomical Timer Coi
200.00
❑
3 Ext Light 3
Walk way less than 10 feet
2
100
335.00 Astronomical Timer Coi
200.00
❑
wide
2/2/2011 EuergyGauge Summit® v3.22 6
t
Piping
No Type Operating Insulation Nomonal pipe Insulation Is Runout?
Temperature Conductivity Diameter Thickness
[F] [ Btu-in/h.sLF] [in] [in]
Fenestration Used
Name Glass Type No. of Glass SHGC VLT
Panes Conductance
[Btu/h.sLF]
Materials Used
Mat No
Acronym
Description
Only R-Value RValue Thickness
Used [h.sLFBtu] [ft]
Conductivity
[Btu/h.fLF]
Density
[Ib/cf]
SpecificHeat
[Btu/lb.F]
Yes
265
Mat1265
Soil, 1 ft
No 2.0000 1.0000
0.5000
100.00
0.2000
❑
48
Mat148
6 in. Heavyweight concrete
No 0.5000 0.5000
1.0000
140.00
0.2000
❑
269
Mat1269
.75" ISO BTWN24" oc
No 2.2321 0.0625
0.0280
4.19
0.3000
❑
23
Mat123
6 in. Insulation
No 20.0000 0.5000
0.0250
5.70
0.2000
❑
11
Mad11
2 in. Insulation
No 6.6800 0.1670
0.0250
2.00
0.2000
❑
94
Mat194
BUILT-UP ROOFING,
No 0.3366 0.0313
0.0930
70.00
0.3500
❑
3/81N
Constructs Used
No
Name
Simple Massless Conductance
Construct Construct [Btu/h.sLF]
Heat Capacity
[Btu/sf.F]
Density
[Ib/cfj
RValue
I[h.sf.FBtu]
2/2/2011 EnergyGauge Summit® v3.22
1056
Mtl Bldg Roof/R-19 Batt
No
No 0.05
1.34
9.49
20.3
❑
Layer Material
Material
Thickness
Framing
No.
[ft]
Factor
1 94
BUILT-UP ROOFING, 3/8IN
0.0313
0.000
❑
2 23
6 in. Insulation
0.5000
0.000
❑
No
Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sEF]
[lb/cf]
[h.sf.F/Btu]
1057
1 ft. soil, concrete floor, carpet and rubber pad No
No 0.27
34.00
113.33
3.7
❑
Layer Material
Material
Thickness
Framing
No.
[ft]
Factor
1 265
Soil, 1 ft
1.0000
0.000
❑
2 48
6 in. Heavyweight concrete
0.5000
0.000
❑
3 178
CARPET W/RUBBER PAD
0.000
❑
No
Name
Simple
Massless Conductance Heat Capacity
Density
RValue
Construct
Construct [Btu/h.sf.F]
[Btu/sEF]
[lb/cf]
[h.SEF/Btu]
1058
Solid core flush (2.25)
No
Yes 0.35
2.9
❑
Layer Material
Material
Thickness
Framing
No.
[ft]
Factor
1 279
Solid core flush (2.25")
0.000
❑
2/2/2011 EnergyGauge Summit® v3.22 8
Simple
Massless Conductance Heat
No Name
Construct
Construct [Btu/h.sLF[
[B
1060 6"CMU with 2"
rigid insulation in both side No
No 0.06
Layer
Material
Material
Thickness
Framing
No.
[ftl
Factor
1
11
2 in. Insulation
0.1670
0.000
2
48
6 in. Heavyweight concrete
0.5000
0.000
3
269
.75" ISO BTWN24" oc
0.0625
0.000
4
11
2 in. Insulation
0.1670
0.000
Capacity Density RValue
to/s£F[ [Ib/cf[ [h.sf.F/Btu[
14.21 79.12 16.1 ❑