FIRE SPRINKLERS HYDRAULIC CAL - PRODUCT DATA SUBMITTAL
I I I TECH DRIVE, SANFORD, FL 32771 Fire Sprinklers, Inc. (407) 328-3000 FAX (407) 328-3001 SCANNED BY St. Lucie County FIRE SPRINKLER SYSTEM HYDRAULIC CALCULATIONS AND PRODUCT DATA SUBMITTAL PROJECT: NAVY SEAL MUSUEM 3300 NORTH HIGHWAY Al FORT PIERCE, FLORIDA 34949 FROM: DELTA FIRE SPRINKLERS INC. D C 1 010 111 TECH DRIVE SANFORD, FL. 32771 DATE: DECEMBER 21, 2010 &OMAS J.ANDERSON,P,E. LiC.®47a1® #io.,a. ozzc FILL COPY Commercial • Residential • Industrial Design 9 Fabrication 9 Installation • Maintenance • Inspection e / � Fire Protection by Computer Design DELTA FIRE SPRINKLERS 111 TECH DRIVE SANFORD FL 32771 407-328-3000 Job Name NAVY SEAL MUSEUM-DA #1 Building NEW ADDITION Location 3300 NORTH HIGHWAY A1A, FORT PIERCE, FL System DA #1 Contract TBA Data File DA#1.WXF Computer Programs by Hydretec Inc. Route 111 Windham N.H. USA 03087 DELTA FIRE Page 1 NAVY SEAL MUSEUM-DA #1 Date 12-21-10 HVdraulic Design Information Sheet" Name - NAVY SEAL MUSEUM Date - 12-21-10 Location - 3300 NORTH HIGHWAY AlA, FORT PIERCE, FL Building - NEW ADDITION System No. - DA #1 -- Contractor - DELTA FIRE SPRINKLERS Contract No. - TBA Calculated By - SEAN Drawing No. - FP-1 OF 1 Construction: ( ).Combustible (X) Non -Combustible Ceiling Height - VARIES Occupancy - DESIGN AREA 41-GALLERY #2-LIGHT HAZARD OCCUPANCY S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E M Area of Sprinkler Operation - 1500 System Type Sprinkler/Nozzle Density - .10 (X) Wet Make VIKING D Area Per Sprinkler - 324 ( ) Dry Model VK532 E Elevation at Highest Outlet - 19'-4" ( ) Deluge Size 3/4" S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 11.2K I Rack Sprinkler Allowance - 0 ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 100 N Note Calculation Flow Required - 273.85 Press Required - 36.473 @ TEST Summary C-Factor Used: 120 Overhead 150 Underground W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-19-10 Cap. - T Time of Test - 8:00 AM Rated Cap.- Elev.- E Static Press - 55 PSI @ Press - R Residual Press - 30 PSI Elev. - Well Flow - 899 Proof Flow S Elevation - 2'-6" U P Location - 3200 NORTH AlA P L Source of Information - FIRE EQUIPMENT SERVICES OF EAST COAST Y C Commodity Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf O C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 DELTA FIRE Page 2 NAVY SEAL MUSEUM-DA #1 Date 12-21-10 .. City Water Supply: Demand: C1 -Static Pressure : 55 D1 - Elevation 7.289 C2 - Residual Pressure: 30 D2 - System Flow 173.854 C2 - Residual Flow 750 D2 - System Pressure 36.473 Hose (Adj City) Hose ( Demand) 100 D3 - System Demand 273.854 Safety Margin 14.650 I 150 I 140 130 p 120 R 110 E 100 I S 90 S 80 U 70 R fi0 j E 50 40 I C2 30 D3 20 10 D1 100 200 300 400 500 600 700 800 900 FLOW (NA1.85) Compute r Programs by Hydratec Inc. Route111 Windham N.H. USA 03087 ,ainy---sea' --..IM _., DELTA FIRE Page 3 NAVY SEAL MUSEUM-DA #1 Date 12-21-10 Fitting Legend Abbrev. Name '/z '/. 1 1Y. 1Yx 2 2% 3 3Y2 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 10 0 6 7 Fsp Flow Switch Potter VSR Fitting generates a Fi ed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 90'Grvd-VcElbow #10 0 0 2 3 4 3.5 6 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 T NFPA 13 90' Flow thru Tee 3 4 5 .6 8 10 12 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Square Inch 10 0 12 9 10 12 19 21 0 0 0 0 0 1 1 2 2 3 4 5 6 7 8 10 11 13 5 8 7 8.5 10 13 17 20 23 25 33 36 40 5 5 6 8 9 13 16 18 24 27 3o 34 40 15 17 20 .. 25 30 35 50 60 71 81 91 101 '121 I I I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD DELTA FIRE Page 4 NAVY SEAL MUSEUM-DA #1 Date 12-21-10 Node Elevation K-Fact Pt Pn Flow Density Area Press - No. Actual Actual Reg. 1 19.33 11.2 10.53 na 36.34 0.1 324 8.7 - 3 19.33 11.2 8.7 na 33.04 0.1 324 8.7 2 19.33 11.2 9.26 na 34.09 0.1 324 8.7 5 19.33 11.2 9.57 na 34.65 0.1 324 8.7 4 19.33 11.2 10.18 na 35.74 0.1 324 8.7 R1 19.33 11.32 na R2 19.33 12.43 na M1 17.33 13.35 na M2 17.33 13.87 na M3 17.33 21.73 na TR 17.33 23.18 na BR -2.5 35.62 na UG1 -2.6 38.58 na TEST 2.5 36.47 na 100.0 The maximum velocity is 10.23 and it occurs in the pipe between nodes M2 and M3 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations -.Hazen -Williams DELTA FIRE Page ' 5 NAVY SEAL MUSEUM-DA 91 Date 12-21-10 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. IV or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 1 36.34 1.682 1T 9.9 10.210 10.528 K Factor = 11.20 to 120.0 0.0 9.900 0.0 R1 36.34 0.0394 0.0 20.110 0.793 Val = 5.25 0.0 36.34 11.321 K Factor = 10.80 3 33.04 1.682 0.0 17.080 8.700 K Factor = 11.20 to 120.0 0.0 0.0 0.0 2. 33.04 0.0330 0.0 17.080 0.564 Val = 4.77 2 34.08 1.682 1T 9.9 6.870 9.264 K Factor= 11.20 to 120.0 0.0 9.900 0.0 R1 67.12 0.1227 0.0 16.770 2.057 Val = 9.69 0.0 67.12 11.321 K Factor = 19.95 5 34.65 1.682 ' 0.0 17.080 9.569 K Factor = 11.20 to 120.0 0.0 0.0 0.0 4 34.65 0.0361 0.0 17.080 0.616 Val = 5.00 4 35.74 1.682 IT 9.9 6.870 10.185 K Factor = 11.20 to 120.0 0.0 9.900 0.0 _ R2 70.39 0.1339 0.0 16.770 2.245 Val = 10.16 0.0 70.39 12.430 K Factor = 19.97 R1 103.47 2.157 1T 12.307 2.000 11.321 to 120.0 0.0 12.307 0.866 M1 103.47 0.0813 0.0 14.307 1.163 Val = 9.08 0.0 103.47 13.350 K Factor = 28.32 R2 70.39 2.157 1T 12.307 2.000 12.430 to 120.0 0.0 12.307 0.866 M2 70.39 0.0399 0.0 14.307 0.571 Ve1= 6.18 0.0 70.39 13 067 K Factor = 18.90 _ M1 103.47 2.635 0.0 16.830 13.350 to 120.0 0.0 0.0 0.0 M2 103.47 0.0307 0.0 16.830 0.517 Val = 6.09 M2 70.38 2.635 1T 16.474 81.710 13.867 to 120.0 0.0 16.474 0.0 M3 173.85 0.0801 0.0 98.184 7.867 Val = 10.23 M3 0.0 3.26 21 13.44 37.580 21.734 to 120.0 0.0 13.440 0.0 TR 173.85 0.0284 0.0 51.020 1.450 Val = 6.68 TR 0.0 3.26 1 Fsp 0.0 16.330 23.184 to 120.0 1 B 13.44 13.440 11.588 * Fixed loss = 3 BR 173.85 0.0285 0.0 29.770 0.847 Val = 6.68 BR 0.0 4.07 5L 47.796 100.000 35.619 to 150.0 1 G 3.186 50.982 2.000 * Fixed loss = 2 UG7 173.85 0.0064 1Zaf 0.0 150.982 0.963 Val = 4.29 UG1 0.0 5.86 1G 3.834 10.000 38.582 to 150.0 1T 38.342 42.176 -2.166 TEST 173.85 0.0011 0.0 52.176 0.057 Val = 2.07 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams DELTA FIRE Page 6 NAVY SEAL MUSEUM-DA #1 Date 12-21-10 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv '•***** Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 100.00 Qa = 100.00 273.85 36.473 K Factor = 45.34 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 r1 _ _ _ Fire Protection by Computer Design DELTA FIRE SPRINKLERS 111 TECH DRIVE SANFORD FL 32771 407-328-3000 Job Name NAVY SEAL MUSEUM-DA #2 Building NEW ADDITION Location 3300 NORTH HIGHWAY A1A, FORT PIERCE, FL System DA #2 Contract TBA Data File DA#2.WXF Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 DELTA FIRE NAVY SEAL MUSEUM-DA#2 Hvdraulic Design Information Sheet Page 1 Date 12-21-2010 Name - NAVY SEAL MUSEUM Date - 12-21-2010 Location - 3300 NORTH HIGHWAY AlA, FORT PIERCE, FL Building - NEW ADDITION System No. - DA #2 Contractor = DELTA FIRE SPRINKLERS Contract No. - TBA Calculated By - SEAN Drawing No. - FP-1 OF 1 Construction: ( ) Combustible (X) Non -Combustible Ceiling Height - VARIES Occupancy - DESIGN AREA #2-OFFICE-LIGHT HAZARD OCCUPANCY S (X) NFPA 13 (X) Lt. Haz. Ord.Haz.Gp. ( ) 1 ( ) 2 ( ) 3 ( ) Ex.Haz. Y ( ) NFPA 231 ( ) NFPA 231C ( ) Figure Curve S Other T Specific Ruling Made By Date E _- M Area of Sprinkler Operation - 900 System Type Sprinkler/Nozzle Density - .10' (X) Wet Make TYCO D Area Per Sprinkler - 324 MAX ( ) Dry Model TY5237 E Elevation at Highest Outlet - 9'-10" ( ) Deluge Size 3/4" S Hose Allowance - Inside - 0 ( ) Preaction K-Factor 11.2K I Rack Sprinkler Allowance - 0 ( ) Other Temp.Rat.155 G Hose Allowance - Outside - 100 N Note DEISGN AREA REDUCED PER SECTION 11.2.3.2.3.1. Calculation Flow Required - 311.66 Press Required - 39.300 @ TEST Summary C-Factor Used: 120 Overhead 150 Underground j W Water Flow Test: Pump Data: Tank or Reservoir: A Date of Test - 10-19-10 Cap. - T Time of Test - 8:00 AM Rated Cap.- Elev.- E Static Press - 55 PSI @ Press - R Residual Press - 30 PSI Elev. - Well -- Flow - 899 Proof Flow S Elevation - 2'-6" U P Location - 3200 NORTH AlA P L Source of Information - FIRE EQUIPMENT SERVICES OF EAST COAST Y C Commodity Class Location 0 Storage Ht. Area Aisle W. M Storage Method: Solid Piled % Palletized % Rack M _ ( ) Single Row ( ) Conven. Pallet ( ) Auto. Storage ( ) Encap. S R ( ) Double Row ( ) Slave Pallet ( ) Solid Shelf ( ) Non T A ( ) Mult. Row ( ) Open Shelf 0 C R K Flue Spacing Clearance:Storage to Ceiling A Longitudinal Transverse G - E Horizontal Barriers Provided: Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 DELTA FIRE Page 2 NAVY SEAL MUSEUM-DA #2 Date 12-21-2010 I City Water Supply: Demand: C1 -Static Pressure : 55 D1 -Elevation 3.175 C2 - Residual Pressure: 30 D2 - System Flow 211.664 C2 - Residual Flow 750 D2 - System Pressure 39.300 Hose (Adj City) Hose ( Demand) 100 D3 - System Demand 311.664 Safety Margin 10.775 150 I 140 130 P 120 R 110 E 100 S 90 I• S 80 U 70 i R 60 E 50 D2 40 C2 30 I 20 10 100 200 300 400 .500 600 700 800 900 FLOW N^1.85) I Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 -- DELTA FIRE Page 3 NAVY SEAL MUSEUM-DA #2 Date 12-21-2010 Fitting Legend Abbrev. Name '/2 % 1 1 1'/4 1'/ 2 2'/: 3 3Y: 4 5 6 8 10 12 14 16 18 20 24 B NFPA 13 Butterfly Valve 0 0 0 0 0 6 7 E NFPA 13 90' Standard Elbow 1 2 2 3 4 5 6 Fsp Flow Switch Potter VSR Fitting generates a Fixed Loss Based on Flow G NFPA 13 Gate Valve 0 0 0 0 0 1 1 1 90' Grvd-Vic Elbow #10 0 0 2 3 4 3.5 6 L NFPA 13 Long Turn Elbow 0.5 1 2 2 2 3 4 T - NFPA 13 90' Flow thru Tee 3 4 5 6 8 10 12 Zaf Ames 3000SS Fitting generates a Fixed Loss Based on Flow i i Units Summary Diameter Units Inches Length Units Feet Flow Units US Gallons per Minute Pressure Units Pounds per Squarle Inch I� I 1 10 0 12 9 10 12 19 21 0 0 0 0 0 7 8 10 12 14 18 22 27 35 40 45 50 61 1 1 2 2 3 4 5 6 7 8 10 11 13 5 8 7 8.5 10 13 17 20 23 25 33 36 40 5 5 6 8 9 13 16 18 24 27 30 34 40 15 17 20 25 30 35 50 60 71 81 91 101 121 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Pressure / Flow Summary - STANDARD DELTA FIRE Page 4 NAVY SEAL MUSEUM-DA #2 Date 12-21-2010 Node Elevation K-Fact Pt Pn Flow Density Area Press No. Actual Actual Reg. 8A 9.83 11.2 8.87 na 33.36 0.1 324 8.7 8 9.83 9.6 na 7 9.83 11.2 10.06 na 35.53 0.1 324 8.7 -, 6 9.83 11.2 10.31 na 35.97 0.1 324 8.7 11A 9.83 11.2 8.7 na 33.04 0.1 324 8.7 11 9.83 9.41 na 10 9.83 11.2 9.79 na 35.04 0.1 324 8.7 9 9.83 11.2 11.96 na 38.73 0.1 324 8.7 L1 9.83 12.57 na L2 9.83 12.6 na L3 9.83 12.63 na L4 9.83 19.0 na M3 17.33 23.1 na TR 17.33 25.19 na BR -2.5 38.0 na UG1 -2.5 41.38 na TEST 2.5 39.3 na 100.0 The maximum velocity is 13.35 and it occurs in the pipe between nodes 6 and L3 ' Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams DELTA FIRE NAVY SEAL MUSEUM-DA #2 Page 5 Date 12-21-2010 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "a. or Ftng's Pe Pv ******* Notes ****** Point Qt Pf/Ft Eqv. Ln. Total Pf Pn 8A 33.36 1.049 1 E 2.0 0.170 8.873 K Factor = 11.20 to 120.0 0.0 2.000 0.0 8 33.36 0.3355 0.0 2.170 0.728 Vel = 12.38 8 0.0 1.682 0.0 13.670 9.601 to 120.0 0.0 0.0 0.0 7 33.36 0.0337 0.0 13.670 0.460 Vel = 4.82 7 35.53 1.682 1T 9.9 9.830 10,061 K Factor= 11.20 to 120.0 0.0 9.900 0.0 L2 68.89 0.1286 0.0 19.730 2.538 Val = 9.95 0.0 68.89 12.599 K Factor = 19.41 6 35.97 1.049 1T 5.0 1.000 10.314 K Factor = 11.20 to 120.0 0.0 5.000 0.0 L3 35.97 0.3855 0.0 6.000 2.313 Vel = 13.35 0.0 35.97 12.627 K Factor = 10.12 11A 33.04 1.049 1 E 2.0 0.170 8.700 K Factor = 11.20 to 120.0 0.0 2.000 0.0 11 33.04 0.3295 0.0 2.170 0.715 Vel = 12.27 11 0.0 1.682 0.0 11.330 9.415 to 120.0 0.0 0.0 0.0 10 33.04 0.0330 0.0 11.330 0.374 Vel = 4.77 10 35.04 1.682 1T 9.9 12.170 9.789 K Factor= 11.20 to 120.0 0.0 9.900 0.0 L1 68.08 0.1259 0.0 22.070 2.778 Vel = 9.83 0.0 68.08 12.567 K Factor = 19.20 9 38.73 1.682 1T 9.9 3.830 11.958 K Factor = 11.20 to 120.0 0.0 9.900 0.0 L1 38.73 0.0444 0.0 13.730 0.609 Vel = 5.59 L168.08_ __ _____ 4.26 _ 0.0 _ __ _10.330 12.567_ to 120.0 0.0 0.0 0.0 L2 106.81 0.0031 0.0 10.330 0.032 Val = 2.40 L2 68.89 4.26 0.0 3.500 12.599 to 120.0 0.0 0.0 0.0 L3 175.7 0.0080 0.0 3.500 0.028 Val = 3.95 L3 35.96 4.26 21T 553.017 20.000 12.627 to 120.0 0.0 553.017 0.0 L4 211.66 0.0111 0.0 573.017 6.368 Vel = 4.76 L4 0.0 2.635 1T 16.474 47.330 18.995 to 120.0 0.0 16.474 -3.248 M3 211.66 0.1153 0.0 63.804 7.358 Val = 12.45 M3 0.0 3.26 21 13.44 37.580 23.105 to 120.0 0.0 13.440 0.0 TR 211.66 0.0409 0.0 51.020 2.087 Val = 8.14 TR 0.0 3.26 1 Fsp 0.0 16.330 25.192 to 120.0 1 B 13.44 13.440 11.588 • Fixed loss = 3 BR 211.66 0.0409 0.0 29.770 1.218 Vel = 8.14 Computer Programs by Hydratec Inc. Route 111 Windham N.H. USA 03087 Final Calculations - Hazen -Williams DELTA FIRE Page 6 NAVY SEAL MUSEUM-DA #2 Date 12-21-2010 Hyd. Qa Dia. Fitting Pipe Pt Pt Ref. "C" or Ftng's Pe Pv ** **** Notes Point Qt PHFt Eqv. Ln. Total Pf Pn BR 0.0 4.07 5L 47.796 100.000 37.998 to 150.0 1 G 3.186 50.982 2.000 ' Fixed loss = 2 UG1 211.66 0.0092 1zaf 0.0 150.982 1.386 Val = 5.22 UG1 0.0 5.86 1G 3.834 10.000 41.384 to 150.0 1T 38.342 42.176 -2.166 TEST 211.66 0.0016 0.0 52,176 0.082 Vel = 2.52 100.00 Qa = 100.00 311.66 39.300 K Factor = 49.71 Computer Programs by Hydratec Inc. Route 111 Windham N..H. USA 03087 TABLE OF CONTENTS 1. PIPE 2. FITTINGS 3. HANGERS 4. SPRINKLER LEADS 5. VALVES 6. DEVICES AND MISC. 1. PIPE WELDED TUBE BERKEIEY _ 1100 NORTH STEEL CIRCLE HUGER, SOUTH CAROLINA 29450 TOLL FREE 888.276.7006 FAX 843.336.7053 Please visit our webalte at www.weldedtube.com for additional information about our company and capabilities. Exceeding Customer Expectations Welded Tube - Berkeley is a leading manufacturer of ERW tubing and pipe products distributed throughout North America. Welded Tube - Berkeley Is located next to the Nucor Berkeley Steel Facility which produces consistent high quality low carbon steel. Welded Tube - Berkeley Sprinkler Pipe Is certified by UL and FM. our Sprinkler Pipe is manufactured in accordance with ASTM Al35/795. Our Mechanical and Structural Tubing is manufactured in accordance with ASTM A500/513. All products are 100% Eddy Current tested to insure consistent weld quality. The Welded Tube - Berkeley facility in Huger, South Carolina also stocks additional sizes beyond those listed. Please call Customer Service @ $88-275-7006 and allow us to fill your tube and pipe needs or email us at wtb_csr@weldedtube.com SIZE 1-114" NOMINAL s ID 1.660" 1.442" 0 109" LIFT rFOOT 61. L8 P[R 1.31 ! 1 21"LIFTS FEET LB 1281 2319 24'lIFTSI FEET LB 1464 2650 15'UFIS j ' FEET: LB 1525 2760 PCSPBITR1JW.OA9 HALF FULL 610 1281 1-172" 1.900" 1.682" 619T 61 209 1281 2677 1464 3060 1525 3187 549 1098 N 2375" 2157" 0109" 37 264 777 2051 B88 2344 925 2442 444 851 2.1727 U75" 2635" 0.120" 17 354 777 2751 888 3144 925 3275 333 629 3" 3500" 3260" 0.120" 19 434 399 1732 456 1979 475 2062 266 532 4" 4500" 4260" 0.120" 19 562 399 2242 - 456 2563 475 2670 .209 399 1-11C NOMINAL 1� -ID 1.660" 1.512" LL 0074" LIEF COUNT 61 LB PER FooTt 1.16 27"11F75 1281 1614 Z4'lIFTS 1464 1845 25'UF75 1525. 1922 I MIRO1fllMOD 915 1830 CAR 1-172" 1.900" 1334" 0083" 61 161 1281 2062 1464 B57 1525 2455 732 1403 2.34 2" 2379° 2.209" 0083" 37 2.03 771 1577 888 1803 925 1878 555 1110 1.89 2-1/2" 2.815" 2.709" 0 083" 37 248 777 1927 888 2202 925 2294 444 925 1.09 3" 3500" 1334" 0.090" 19 328 399 1309 456 1496 475 1558 361 684 100 4" 4.560 4310" 0.105" 19 493 399 1967 456 2248 475 2342 228 456 1.00 Welded Tube - Berkeley also stocks additional sizes (6, 8'1 of sprinkler pipe products. Our ERW Sch 10 and Schi pipe is In compliance with A-135/795 sprinkler pressure rated @ 300psi. ALL. PRODUCTS ARE MANUFACTURED IN THE USA a 0e usos® `FM' Product Description: AWWA C-900 Municipal Water Pipe North American Pipe's AWWA C-900 PVC product line is manufactured to meet the needs of modem municipal water distribution systems. With top quality raw materials and modem processing technology North American Pipe's C-900 pipe meets all industry standards in addition to our own rigorous quality control standards. North American Pipe's C-900 pipe utilizes Reiber style gaskets throughout the entire product offering. North American Pipe produces a full range of CIOD pipe in DR-14, DR-18, and DR-25 classifications. Whether specifying or installing our pipe you can be assured that North American Pipe will provide the pipe "Right, On Time, All the Time". TFiis'pFiiducf'isimade"i`n accoidarice•with'the'follo`wing'specificatio`nsd AWWA C900 ASTM D1784 ASTM D3139 ASTM F477 ANSI/NSF 14 ANSI/NSF 61 PPI TR-3 UL 1285 FM 1612 (Sho�IF.orm,S ._eeion fcati' 1 p ,. .for North American PIpe,C-orporaton, ,AWWArC-900 Munrcipal Wate�Prpe, .Water main distnbiitibn pipe "shall be made in,accordance with AWWA C900 -from a compound• conforrnmg to a cell elassificatton of 12454 as �tlefined by.ASTM D1784 Integral bellssliall ' dnc fporatg gaskets meeting th f qulw. rements'of ASTM `F477�and be locked iri 64 Ei i e&., The, ,ass.embbllea lomt sH511 meet thefequireme`nts of- ASTM D3139 The;laymg length of the pipe shall bed 20 fe`et The pipe,and gasket must be tested and, approved:for contact with potable water if, accordaric�e wIt ANSI/NSF W1 The pipe:and gaskehall be listed by1Unde`_rwnfers Laboratory';', ,and approved bysFastoryMutiial '� >•�, ei 6ell V� ~'� I�TED Q<S> A"RUVM AWWA C-900 Municipal Water Pipe (NOMINAL'- (OUTS.I)E `APPROXd `*APPROX T INSERT• 'pIP,,E:S)ZE bm .:NOM_ BELLDIA: BELLDE -' MARK (OD) `(BD) (C) 41L) 4" 4.80 6.50 6.11 3.88 6" 6.90 9.25 7.34 5.13 8" 9.05 11.75 9.08 6.13 10" 11.10 14.25 9.75 6.63 12`' 13.20 16.75 11.02 7.38 PC'100 fPG+150' "PG 200' NOMINAL DR 25 4DR_;18 DR;14 (P)PE?SIZE .(Tj (r)A) , .. —4" --- .192 .267 .343 6" .276 .383 .493 8" .362 .503 .646 10" .444 .617 .793 12" .528 .733 .943 Note: These dime Ions are for mdonating p 1poses only •Dimensio.gi.fos Appm.BeNDimaeter(BD)isf higheApmsmrecless 6* Nominal deptk depth will vary by pressure doss A TYTONO JOINT PIPE Sizes 3" - 24" RLW&Iftft� Imo-- B Nominal laying length.--] FASTITEO JOINT PIPE Sizes 30" - 36" A I B Nominal laying length* --i NOMINAL THICKNESS FOR STANDARD PRESSURE CLASSES OF DUCTILE IRON PIPE Outside Pressure Class* Size Diameter 150 200 250 300 350 Inches Inches Normal Thickness Iriahes 3 3.96 ... ... ... .... 0.25** 4 4.80 ... ... ... ... 0.25** 6 8.90 ... ... ... ... 0.25 8 9.05 ... ... ... ... 0.25 10 11.10 ... ... ... ... 0.26 12 13.20 ... ... ... ... O:28 14 15.30 .. 0.28 0.30 0.31 16 17.40 .. 0.30 0.32 0.34 18 19.50 .. 0.31 0.34 0.36 20 21.60 .. 0.33 0.36 0.38 24 25.80 .. 0.33 0.37 0.40 0.43 30 32.00 0.34 0.38 0.42 0.45 0.49 36 38.30 0.38 0.42 0.47 0.51 0.56 *Pressure Classes are defined as the rated water pressure of the pipe in psi. The thicknesses shown are adequate for the rated water working pressure plus a surge allowance of 100 psi. Calculations are based on a minimum yield strength of 42,000 and a 2.0 safety factor times the sum of the working pressure and 100 psi surge allowance. *Calculated thicknesses for these sizes and pressure rat- ings are less than those shown above. Presently these are the lowest nominal wall thicknesses available in these sizes. NOTE: Per ANSI/AWWA C150/A21.50 the thicknesses above include the 0.08" service allowance and the casting tolerance listed below by size ranges. SIZE (Inches) CASTING TOLERANCES (Inches) 3-8 - 0.05 10-12 - 0.06 14-36 - 0.07 630 Linn Street • Coshocton, Ohio 43812 * (740) 622-6651 * FAX (740) 622-4272 3 a a STANDARD DIMENSIONS AND WEIGHTS OF 3" THROUGH 36" PUSH -ON -JOINT DUCTILE IRON PIPE 18-Foot Laying Length Size Pressure Thickness Outside Diameter* Weight Avg.Weight (Inches) Class Per Lengtht Per Foottt Inches Pounds 3** 350 0.25 3.96 185 9.2 4** 350 0.25 4.80 225 11.3 6 350 0.25 6.90 300 16.6 8 350 0.25 9.05 395 22.0 10 350 0.26 11.10 510 28.4 12 350 0.28 1120 655 36.4 14 250 0.28 15,30 770 42.9 14* 300 0.30 15.30 825 45.8 14r 350 0.31 15.30 850 47.2 16 250 0.30 17.40 940 52.3 16* 300 0.32 17.40 1000 55.5 16* 350 0.34 17.40 1060 58.8 18 250 0.31 19.50 1090 60.5 18* 300 0.34 19.50 1185 65.9 18* 350 0.36 19.50 1250 65.9 20 250 0.33 21.60 1290 71.6 20* 300 0.36 21.60 1395 77.6 20* 350 0.38 21.60 1470 81.6 24 200 0.33 25.80 1550 86.1 24* 250 0.37 25.80 1725 95.8 24* 300 0.40 25.80 1855 103.5 24* 350 0.43 25.80 1985 116.2 30 150 0.34 32.00 2000 11.2 30* 200 0.38 32.00 - 2220 - 123.2 30* 250 0.42 32.00 2435 135.2 30* 300 0.45 32.00 2595 144.2 30* 350 0.49 32.00 2810 156.1 36 150 0.38 38.30 2675 148.7 36* 200 0.42 38.30 2935 163.1 36* 250 0.47 38:30 3260 181.1 36* 300 0.51 38.30 3520 195.5 36* 350 0.56 38.30 3840 213.4 * Tolerance of O.D. of spigot end: 3-12 in., 30.06 in., 14-24 in., +0.05 in., -0.08 in., 30-36 in., +0.08 in., -0.06 in. **Available in 20' lengths. t Including bell; calculated weight of pipe rounded off to nearest 5 lbs. tt Including bell; average weight, per foot, based on calculated weight of pipe before rounding. 4 630 Linn Street - Coshocton, Ohio 43812 - (740) 622-6651 - FAX (740) 622-4272 i RATED WORKING PRESSURE AND MAXIMUM DEPTH OF COVER Laying Condition Sizes Pressuret Class Nominal Thickness Type 1 Type 2 Type 3 Type 4 Type 5 (Inches) (psi) (Inches) Trench Trench Trench Trench Trench Maximum Depth of Covert - feet 3 350 0.25 78 88 99 100§ 100§ 4 350 0.25 53 61 69 85 100§ 6 350 0.25 26 31 37 47 65 8 350 0.25 16 20 25 34 50 10 350 0.26 11" 15 19 28 45 12 350 0.28 10" 15 19 28 44 14 250 0.28 tt 11" 15 23 36 14 300 0.30 tt 13 17 26 42 14 350 0.31 tt 14 19 27 44 16 250 0.30 tt 11" 15 24 34 16 300 0.32 tt 13 17 26 39 16 350 0.34 ft 15 20 28 44 18 250 0.31 tt 10" 14 22 31 18 300 0.34 ft 13 17 26 36 18 350 0.36 tt 15 19 28 41 20 250 0.33 tt 10 14 22 30 20 300 0.36 ft 13 17 26 35 20 350 0.38 tt 15 19 28 38 24 200 0.33 tt 8" 12 17 25 24 250 0.37 ft 11 14 20 29 24 300 0.40 ft 12 17 24 32 24 350 0.43 tt 15 19 28 37 30 150 0.34 tt ... 9 14 22 30 200 0.38 tt 8" 12 16 24 30 250 0.42 tt 10 14 19 27 30 360 0.45 tt 12 16 21 29 30_ _ _ _350 _ _ _ _ _ 0.49 tt 15 19 _ 25 33 36 150 0.M tt ... 9 14 21 36 200 0.42 tt 8" 12 15 23 36 250 0.47 tt 10 14 18 25 36 300 0.51 tt 12 16 20 28 36 350 0.56 1 tt 15 19 24 32 - t Ductile -iron pipe Is adequate for the rated working pressure indicated for each nominal size plus a surge allowance of 100 psi. Calculations are based on a 2.0 safety factor times the sum of working pressure and 100 psi surge allowance. (See ANSI/AW WA C150 A21.50 for design formula.) Ductile -iron pipe for working pressures higher than 350 psi is available. t An allowance for a single H-20 truck with 1.5 impact factor is included for all depths of cover. § Calculated maximum depth of cover exceeds 100 ft. "Minimum allowable depth of cover is 3 ft. tfFor pipe 14 in. and larger, consideration should be given to the use of laying conditions other than Type 1. 630 Linn Street - Coshocton, Ohio 43812 • (740) 622-6651 • FAX (740) 622-4272 MECHANICAL JOINT FOR PIPE AND FITTINGS ANSI/AW WA-CI11 /A21.11 Standard Mechanical Joint for Pipe and Fittings ALL DIMENSIONS ARE IN INCHES Size Dimensions Accessories A B F J K2t Bolts Per Joint _ Wgt. in Lbs.ft 3 3.96 2.50 4.06 6.19 7.69 4-5/8 x 3 - 7 4 4.80 2.50 4.90 7.50 9.12 4-3/4 x 3 1 /2 10 6 6:90 250 7.00 9.50 11.12 6-3/4 x 3 1 /2 16 6 9.05 2.50 9.15 11.75 13.37 6-3/4 x 4 25 10 11.10 2.50 11.20 14.00 15.62 8-3/4 x 4 30 12 13.20 2.50 13.30 16.25 17.88 8-3/4 x 4 40 14 15.30 3.50 15.44 18.75 20.25 10-3/4 x 4 1 /2 45 16 17AO 3.50 17.54 21.00 22.50 12-3/4 x 4 1 /2 55 18 19.50 3.50 19.64 23.25 24.75 12-3/4 x 4 1 /2 65 20 21.60 3.50 21.74 25.50 27.00 14-3/4 x 4 1/2 85 24 25.80 3.50 25.94 30.00 31.50 16-3/4 x 5 105 30` 32.00 4.00 32.17 36.88 39.12 20-1 x 6 170 36` 1 38.30 1 4.00 1 38.47 1 43.75 1 46.00 1 24-1 x 6 235 `Available on fittings only. t K2 is outside diameter of glands across bolt holes. tt Shows total weight of gland, gasket, and a set of bolts required to complete one joint. MECHANICAL JOINT DUCTILE IRON FITTINGS Mechanical Joint fittings are used with Mechanical Joint, Push -On and other plain end centrifugally cast pipe of the same outside diameter. To permit assembly with Push -On pipe, plain ends of all Mechanical Joint fittings are beveled. Mechanical Joint fittings are available in ductile iron for the pressure ratings shown in the various tables. Unless specifically ordered otherwise, Mechanical Joint fittings are always shipped complete with joint accessories. The successful operation of the mechanical joint requires that the plain end be centrally located in the bell and that adequate anchorage shall be provided where abrupt changes in direction and dead ends occur. The rubber gasket seals most effectively (particularly when sealing air) if the surfaces with which it comes in contact are brushed thoroughly with a wire brush just prior to assembly. This thorough brushing removes all loose rust or foreign material which may be present and provides clean surfaces which should be brushed with soapy waterjust prior to slipping the gasket over the plain end and into the bell. Soapy water brushed over the gasket prior to installation also removes loose dirt and lubricates the gasket as it is forced into its retaining space. Accessories -gland, gasket, and bolts -are not assembled on pipe and fittings when shipped. Note: Unless specifically ordered otherwise, mechanical joint bends, tees, and crosses will always be fur- nished with MJ BELL on ALL openings. 630 Linn Street • Coshocton, Ohio 43812 • (740) 622-6651 • FAX (740) 622-4272 STANDARDS APPLICABLE TO DUCTILE IRON PIPE AND FITTINGS Thickness Design of Ductile Iron Pipe ANSI/AWWAC150/A21.50 Ductile Iron Pipe for Water and Other Liquids ANSI/AW WA C151/A21.51 FEDERAL WWP421 D, Grade C Ductile Iron Pipe for Gravity Flow Service ANSI/ASTM A746 Ductile Iron Fittings for Water and Other Liquids 30" through 36" ANSI/AW WA C110/A21.10 Ductile Iron Compact Fittings 3" through 24" ANSI/AW WA C153/A21.53 Flanged Fittings ANSI/AW WA C110/A21.10 ANSI B16-1 Ductile Iron Pipe with Threaded Flanges ANSI/AWWAC115/21.15 Coatings and Linings: Asphaltic ANSI/AW WA C151/A21.51 ANSI/AW WA C110/A21.10 ANSI/AW WA C1531A21.53 Cement Lining ANSI/AW WA C104/A21.4 Various Epoxy Linings and Coatings - MANUFACTURER'S STAN- DARD Exterior Polyethylene Encasement ANSI/AWWAC105/A21.5 Joints —Pipe and Fittings Push -On and Mechanical Rubber -Gasket Joints ANSI/AWWAC111/A21.11 FEDERALWWP421 D Flanged ANSI/AWWAC115/A21.15 ANSI B16.1 Grooved and Shouldered ANSI/AW WA C606 Pipe Threads ANSI B2.1 Installation ANSI/AW WA C600 LAYING CONDITIONS Type 1t Flat -bottom trench.'Loose backfill. Type 2 Flat -bottom trench.'Backflll lightly consoli- dated to centerline of pipe. Type 3 Pipe bedded in 4- in. minimum loose soil."B ackfill lightly consolidated to top of pipe. Type 4 Pipe bedded in sand, gravel or crushed stone to depth of 1/8 pipe diameter, 4-in. min- imum. Backfill com- pacted to top of pipe. (Approxi- mately 80% Stan- dard Proctor AASHTO &T-99. Type 5 Pipe bedded in compacted granu- lar material to cen- terline of pipe Compacted granu- lar or selected" material to top of pipe (Approxi- mately 90% Stan- dard Proctor AASHTO &T-99. Notes:Consideration of the pipe -zone embedment conditions included in this figure may be influenced by factors other than pipe strength. For additional information on pipe bedding and backfll, see ANSI/ AW WA C600. For nominal pipe sizes 14 in. and larger, consideration should be given to the use of laying condi- tions other than Type 1. t Flat bottom is defined as undisturbed earth. '• Loose soil or select material is defined as native soil excavated from the trench, free of rocks, foreign materials, and frozen earth. American Association of State Highway and Transportation Officials, 444 N. Capitol St. N.W., Suite 225, Washington, DC 20001 630 Linn Street • Coshocton, Ohio 43812 • (740) 622-6651 • FAX (740) 622-4272 MECHANICAL JOINT PIPE MAXIMUM ALLOWABLE JOINT DEFLECTION Size of Pipe Y-Maximum Joint Deflection in Degrees X-Deflection in Inches 18 Ft. Length Approximate Radius in Feet of Curve Produced by Succession of Joints 18 Ft. Length 3 8'- 18' 35' 140• 4 8'-18, 35" 140' 6 70-7' 30 145 8 5' - 21' 20 195 10 5' - 21' 20 195 12 5°-21' 20 195 14 3° - 35' 13.5 285 16 3' - 35' 13.5 285 18 3' - 0' 11 340 20 3' - 0' 11 340 24 2' - 23' 9 450 '20 Ft. Length PUSH -ON JOINT PIPE MAXIMUM ALLOWABLE JOINT DEFLECTION Size of Pipe Y-Maximum Joint Deflection in Degrees X-Deflection in Inches Approximate Radius in Feet of Curve Produced by Succession of Joints 3" same as 4" 1S Ft. Length 20 Ft. Length 18 Ft. Length 20 Ft. Length 3 5' ... 21 ... 230 4 5' ... 21 ... 230 6 5` 19 ... 205 ... 8 5° 19 ... 265 ... 10 5' 19 ... 205 ... 12 5' 19 ... 205 ... 14 4° 15 ... 260 ... 16 4° 15 ... 260 ... 18 3' 11 ... 345 _ ... 20 3' 11 ... 345 ... 24 3' 11 ... 345 ... 30 3' 11 ... 345 ... 36 1 3° 1 11 345 630 Linn Street ° Coshocton, Ohio 43812 ° (740) 622-6651 • FAX (740) 622-4272 .a V V (O NO O W t0 V NO I�: 7NOd M7 q aD W O)mmMnNMT V OO11M 10 OlLL OI���������M4��NONC'Mn V [Om IhNN rO N[G OiG d'n�yy6)N OIN O)tn •a a a � J a}� O O 0� 0 Co, m C 0 0� 0 M r O M N T A B M Om V,'m' M W b N� � �Om G a 10J OOi (00 a00 100 100 aND NNNNNNNN th M M M M M •O C V m C d' m m M M M m M M n n OO m n n� W W � OJ —MNMMMMM—MMMMMVVV'C'V �f nnnnnnn .-��-.- NNNNNNNMMMMt�t7 t�JMM MMMMMMMMtp 3-- d m JQ 3 V V Cl! MNRM M OD M M'Q N O M Lq q V M qr%q V nNpp 0 MnnMM0 to NMMON T NNNNNtMMMMMMth tn�l VO' VAC V V V V mN�M�NYMJ fMD ` Qa O J O O. } N 1a 10 Y] N 10 10 N 10 O 10 M IA 10 O O 10 N N O N O YJ N O O O M O H N O 1(l N O 1n O m N � m 0�� L •r N N N N N N N N fh M M MM M V R V C V V m m-M M M m.M M n n M M n n M M M � m M � � a 3J Oj ,= O) W M M M M — — N N N N N N N N N N N N N N M M M M M MMMMM M 3m fq M O O M N (d N M M O) la l.: M � m Nm m� MM li N M N0 n 1O N R1� O m m mN M of W N M M N M M n N O �mr a MM�-M�N N N.N N N N M M M M M M M M V•C V M O V' V m m m p m m M a Y M M M M M M 0 0 0 0 OHO O O O O O O O m m m m m m m 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 O O O O N N N N N N N M M M M 0i O� 60 M M M M M M M M M M M M M M M M M i+i nin oim m ivvvavvao'<o tO 6 6 tG O)OI O) 0)601 O)�6--eM-Cd —1------- d da Ca mMnOMO)NmM mM V nOMnOMMMNmMNmM n 'O nOMMMMMMN V �Cr;m Mav, v, v,M c;Mo YV NNt7 'QNNMMMVNNth [h l7 V'QNMMMMQCN (n In l7 M 0 u� FL- N , dN m a U m m m m m m m m m m m m m m m m m m m m mom m m m m m m m m m m m m m m m m m m m m m H N _s m u c 8 Ea 20 FITTINGS MODEL Z05 RIGID COUPLING - Angle -Pad Design - The Shurjoint Model Z05 is an angle -pad design rigid coupling for moderate pressure piping services. including fire mains, long straight runs and valve connections. The angle -pad design allows the coupling housings to slide along the bolt pads when tightened. The result is an offset clamping action which provides a rigid joint which resists so- called 'snaking' of a long straight run. Support and hanging requirements correspond to ANSI B31.1, B31.9 and NFPA 13. With the removal of only one bolt you can make a fast and easy'swing-over' installation. Sizes available: 32mm - 200mm / 1-1/4" - 8" Working Pressure: Up to 24 bar / 350 psi LN0."X, ' N'ommall �" Maz,;Workmg Maz Fnd - --- - "-Dim`ensions�' Size PPe:O D 1 Press a L`4dl t _-Aral Dlsplaxcemerll: Bolls size, WeighF' A- - B, s 1c L_mm/in �'_;__mm/in1_. is Bar/P51: _: :_. kIJ/Lb's,_ i._. mm/mi i_. trim/in _ __mm/im _.1_mm/in -__! _ mm/in;_--I. Kss/Lbs_. 32 422 24 3.37 0-12 66 102 46 MID X55 0.6 1.25 1.660 350 757 0-0.05 2.60 4.00 181 3/8x2-1/8 1 1.4 40 483 24 4.42 0-12 72 109 46 MIO X55 07 15 1900 350 990--" 0=0.05 283 429 t81 3/8 x2-1/8-- ---15- 50 60.3 24 6.90 0- V 85 117 47 M10 X 70 0.8 2 2375 350 1550 0 - 0.07 335 4.61 185 3/8 x 2-3/4 1.7 65 73.0 24 70.11 0-V 98 132 47 M10X70 0.9 25 2875 350 2270 0 - 0.07 3.86 5.20 185 318 x 2-3/4 21 65 76.1 24 1L01 0 - V 100 136 47 M10 X 70 10 25 1 3.000 1 350 2475 1 0 - 0.07 3.94 535 185 1 3/8 x 2-3/4 2.2 80 88.9 24 14.99 0-1.7 111 148 48 M10X70 12 3 3500 350 3365 0 - 0.07 4.45 5.83 188 3/8 x 2-3/4 26 1aO 108.0 24 2211 0-4.1 142 V6 54 M10 X70 16 4 4.250 350 4963 0-0.16 5.59 6.93 2.13 318x2-3/4 3.6 100 1143 24 2497 0-4.1 146 182 53 MIOX70 19 4 4500 350 5565 0-0.16 5.75 7.17 209 3/8x2-3/4 4.1 125 U3.0 20 28.91 0-4.1 VO M4 54 M12 X75 23 5 5.250 300 6491 0 - 0.16 6.69 8.82 213 1/2 x 3 5.1 125 1391 20 31J2 0-4.1 173 227 53 M12 X75 26 5 5500 300 7125 0 - 0.16 6.81 R94 209 1/2 x 3 5.7 125 14U 20 3245 0- 4.1 175 229 53 M12 X 75 2.6 5 5563 300 7290 0 - 0.16 6.89 9.02 209 1/2 x3 5.7 ISO 159.0 20 40.98 0-4.1 193 250 54 M12X75 28 6 6.250 300 9199 0-0.16 7.90 9.84 213 1/2x3 6.1 ISO 165.1 20 4430 0-4.1 200 246 54 M12X75 3.1 6 6500 300 9955 0-0.76 7.87 9.69 213 1/2x3 6.8 ISO 1683 20 46.02 0-4.1 203 249 54 M12 X75 3.1 6 6.625 300 10340 0-0.16 8.00 9.80 213 1/2x3 6.8 200 219.7 20 78.00 0 - 4.8 264 330 64 MI6 X 135 6.1 8 8.625 300 77525 0-0.19 70.40 U99 2.S2 5/8x5-5/16 11.4 20011S 2163 20 76.08 0 - 4.8 260 340 64 M20 X 120 7.4 8 8516 300 7079 0-0.19 10.24 U39 250 3/4 x4-3/4 16.2 M SHURJOINT® MODEL 7706 REDUCING COUPLING The Shurjoin[ Model 7706 reducing coupling allows for direct reduction on a piping run and eliminates the need for a concentric reducer and couplings. The specially designed rubber gasket helps prevent small pipe from telescoping into larger pipe during vertical assembly. Caution: The Model 7706 couplings should not be used with an end cap, as the end cap may be sucked into the pipe when draining the system. �■ 'sI DR 1�1-- . LI IInD °Noi,im nal Prpe Max: Woikmg M x. En'd T Axralr' Deflect on -_ Drmens 5m _ i Degree Per Prpe. An r- B. C Size, OD: Pressure L. Drspiacemeht B It§_ a .;Weight nr_ t-mm/i`n � s •Bar)PSIi WAISM ._ mui/in._. .Co in") mm/m iri/ft 1mm/m`� imm/m 4mm/m`. 1 mm/rri4: K s/L6s 40x 32 463 x422 24 2.80 0-32 33.0 72 108 46 M10X11 0.9 Is x L25 1900 x 1.660 350 990 0 - 0.13 3° 48 0.40 283 4.25 L81 3/8 x 2-1/e 2.0 50.40 60.3 x 483 24 4.40 0-32 26.0 85 122 48 M10X55 0.9 2 x 15 2375 x 1.900 350 1550 0 - 0.13 3" 02 0.31 335 4.80 1.89 3/8 x 2-1/8 20 65 x 50 73.0 x 603 24 655 0 - 32 22.0 96 144 48 MIO X 55 1.2 2.5x2 2875 x 2.375. 350 2270 0 - 0.13 2--30• 0.26 378 5.67 189 3/8 X 2-1/8 26 65 x 50 763 x 603 24 6.85 0 - 32 210 102 138 48 M10 X 55 12 __ 2 5 x 2 _ 3_.000 x 2.375 350 2480 0 - 0.13 2--24 025 4.02 5.43 189 3/8 x 2-1/8 26 80 x50 88.9 x 603 24 6.85 0-32 18.0 116 168 48 X75 15 3 x 2 3500 x 2375 350 3370 0 - 0.13 2' 04 0.22 457 6.61 189 x 3 33 BOx 65 88.9 x 73.0 24 10.04 0-3.2 18.0 176 168 48 X75 V 3x2-5 350Dx2875 350 3370 0-0.13 2' 04 0.22 457 6.61 189x3 37 80x 65 88.9 x 76.1 24 10.91 0-3.2 78.0 116 168 48 X75 17 3 x 2-5 3500 x 3.000 350 3370 0 - 0.13 2° 04 0.22 457 6.61 189 x 3 37 100x 50 1143 x603 24 6.85 0-4.8 21.0 146 198 52 X75 24 4x-2 - -4300x 2375 - 350 5560 0-0.19 2 -04• -0.25- --575 7.80 2.05 -x3-- -53- 100x65 t143 x73.0 24 10.04 0-4.8 21.0 146 198 52 X 75 rM127 2.6 4x25 4500 x2.875 350 5560 0-0.19 2' 24 Us 575 7.80 2.05x3 57 100x 65 1143 x 76.1 24 10.91 0-4.8 2to 146 198 52 X75 26 4 x 25 4500 x 3.000 350 5560 0 - 0.19 2' 24 0.25 575 7.80 205 x 3 57 100x 80 1143 x88.9 24 14.89 0-4.8 2L0 146 198 52 X75 24 4 x 3 4500 x 3500 350 5560 0 - 0.19 2° 24 0.25 575 7.80 205 x 3 5.3 125x 100 1413x 1143 24 24.61 0-6A 23.0 160 250 52 X90 3.8 5x4 5500 x 4500 350 8310 0-025 2' 36 O.V 630 9.84 205 3-1/2 8.4 150x80 165.1 x 8&9 24 14.89 0-6A 20.0 202 269 52 X90 4.6 6.3 6300 x 3500 350 11610 0 - 0.25 2° 14 023 7.95 1059 205 5/8 x 3-1/2 1 10.1 150 x 80 1683 x 8&9 24 74.89 0. 6A 19.0 208 V5 52 M76 X 90 4.6 6 X 3 6.625 x 3500 1 350 U060 0 - 0.25 2° 12 0.23 8.19 10.83 205 5/8 x 3-1/2 10.1 150 x 100 165.1.1143 24 24.61 0 - 6A 20.0 202 269 52 MI6 X 90 4-5 6 x 4 6500 x 4.500 350 11610 1 0 - 0.25 2' 14 0.23 7.95 1D59 2.05 5/8 x 3-1/2 9.9 150 x 100 7683 x n43 24 24.61 0-6.4 19.0 208 275 52 M16 X 90 4-56 x 4 6.625 x 4500 350 12060 0-0.25 2° 12 023 8.79 1 10.83 1 205 5/3 x 3-1/2 9.9 200 x 150 219.1 x 1683 24 5335 0 - 6.4 15.0 260 334 57 M20 X 720 7.6 e x 6 8.625 x 6.625 350 20440 0 - 025 r 40' 0.18 1024 73.15 224 3/4 x 4-3/4 167 200 x 150 219.1 x 1611 24 5135 0 - 6.4 15.0 260 334 57 M20 X 720 7.6 8 x 6 &625 x 6500 350 20440 0 - 0.25 411' 0.18 10.24 13.15 224 3/4 x 4-3/4 IU Deflection or angular movement is the maximum value that a coupling allows under no internal pressure. (, SHURJOINT® MODEL 7113 11-1/4 ELBOW Shurjoint grooved fittings are cast of ductile iron except where indicated (SM. C is #L Fig. 7110 90' Ell,.. Fig.7112 Fig. 7113 27, 11V Elbow I I-IW Elbow Pm:N� * C-E C-EC-ELa ii*F-- Fig. 7111 Fig. 7112 Fig. 7113 45'El boo, 22-112* Elbow (Wcldcd) 11-114* Elbow (W&d) Nominal-7- . Size - -- P- 'Pe OV ---9O,Elb,0iv----, 45. EIhuw.,_-.1/2, � - --- - -2. - A7,11 Elbow .---. n' rn_,j- Z----C,.E-- LKr5/LbSZ -C!-�'E� --i K�s/Llis C.-:- E K�CSILU-S 7- c ZE J`K�L/Lb-i,�'� 25 33.4 57 0.3 45 0.2 1 1.315 125 07 175 0.4 - - - 32 412 70 05 45 03 45 0.3 35 02 1.25 1.660 275 11 175 0.7 715 SW 0.7 138 SW 0.4 40 483 70 09 45 0.4 45 0.6 35 03 Is 1900 275 Is Vs 0.9 175 U 138 SW Oy 50 603 83 0.9 51 09 48 0.8 35 0.8 2 2375 3.25 2.0 zoo 15 1.88 18 1.38 7.8 65 73.0 95 1.2 57 0.9 51 10 38 to 25 2875 375 2-6 225 zo I zol 2-2 150 65 76.1 95 1.4 57 1.0 51 110 38 7.0 2.5 3.000 325 3.1 225 22 zol 22 ISO 2.2 80 88.9 108 ZI 64 13 57 14 38 1.1 3 3.500 425 4.6 230 2.9 2.25 3.1 150 2.4 90 101.6 114 2.5 - - - - 3.5 4.000 4.50 5.6 - - - - 100 10&0 W 3.5 76 2.0 - - 4 4.250 5Z0 7.7 3.00 4.4 - - 100 114.3 W 28 76 zo 73 2.0 45 ts 4 4.500 5.00 62 3.00 4.4 2.88 4.4 1.75 33 Us 141.3 140 5.0 83 35 73 3.3 51 2.7 5 S363 530 Ito 325 79 2.88 73 zoo sw 5.9 125 133.0 140 4.1 83 21 - - 5 5150 550 9.0 3.25 5.9 - - 125 1399 140 5.0 83 3.5 73 3.3 51 2.7 5 5.500 550 Ito 3.25 7.7 188 7.3 zoo sw 5.9 ISO 1683 765 6.4 89 4A 79 5.0 51 3A 6 6.625 650 14.1 3.50 9.7 3.12 Ito zoo 75 150 159.0 765 6.0 89 3.8 - 6 6.250 630 U.2 330 8.4 - 150 165.1 165 5.7 89 4A 79 so 51 3.4 6 6.500 6.50 115 3.50- 9.7 3.12 Ito zoo 7.5- 200 219.1 197 Us 108 9.0 98 10.0 51 5.5 a 8,625 775 2.7.5 4.25 19.8 3.88 22.0 zoo 121 200JI5 216.3 197 12-5 Tog 9.0 98 10.0 - 8 8.516 795 27.5 4.25 19.8 3.88 220 - - 250 273.0 229 24.0 121 T7.0 ill 13.6 54 6.6 70 10.750 9.00 52.8 4.75 37.4 438 29.9 213 143 250JIS 267.4 229 24.0 121 V.0 ill 13.6 54 6.6 70 10,528 9.00 528 495 37.4 438 29.9 113 145 300 323.9 254 35.0 133 225 124 183 57 8.5 12 12.750 10.00 77.0 5.25 495 4.88 SW 403 225 lay 300j:5 3185 254 35.0 133 225 124 18.3 57 8.5 12 12539 10.00 77.0 5.25 49.5 4.88 SW 40.3 2.25 18.7 350 355.6 280 35.0 152 220 127 21.0 89 14.6 14 14.000 noo 77.0 6.00 48.4 5.00 sw 46.2 3.50 SW 32.1 400 406.4 305 43.0 184 44.0 W 24.0 102 19.0 16 16,000 MOO 94.6 7.25 96.8 5.00 sw 52.8 4.00 5W 41.8 450 457.2 394 75 203 46.6 740 30.0 114 24.0 is 18.000 1550 165.0 8.00 1025 sso sw 66.0 430 SW szs Soo 508.0 438 920 229 47.6 52 35.3 W 30.0 20 20.000 V.25 2024 9.00 104.7 6.00SW 79.9 5.00 SW 66.0 550 558.8 12-9 260 80.0 178 to 152 46.0 22 2200O 0. 2.O 1100 sw 176*0 7.00 sw 1112 6.0OSW 1012 600 609.6 508 129.0 28D 98 51.0 152 46*0 24 24.000 20.00 2818 1100 �6.o 0 7.00 SW 1112 6.00SW 101.2 SM Segment -welded steel. rMSHURJOINV 0 3 J A d amr W u � an m y Q O W W to !p L h- U et 0 3 o tr o o v m n n n c v W W W O � c o o y m 000 u �S`AS 9NIdId�03A0089 1 .m I mN m0NN O`= MvI vl vl iI mvIpN OP0 bn m� p0 00 0"0 NON 00 nOPP O0mN ONmN bY i r40 N PO r1/?101yl, m MOOP m PNN00 Mn {�H �,Otd y O �N OA O ry Ul ry0NOM0 1� d� OIA�O �m�0 �mO0 1o,0 mN 2,q ryON�OO{ OP N IPAO N N �O I� mNm NO ell m0 ,^O1 bM m� II O^�OA �0 ' N0 IAO NuI iV ul m0 n0 MO .�O 00 �O � 1 u I I PN ^n vm11Mi1 �ry Cn �� ^n T� ^n Nm NO I I I+1 t� I ii M^ ma 1 I M� Pm ynj0 Pm A1N IAO uf� m0 ufN �Ob nT mN mVl mCJ 0O 0O I qM° ON nm mN mNmNT ^O o N OM {N +N^ NO No 6p :!] Mm N ONoOj up TN V^O OVNmO�o- v y 3 3 3 3 3 3 3 J: nMM O nA^ m n m m IA m mm e no po .Ao Ino nln nm mN3 NONOPO m3 NNO NO 0 NO 00 MO Popo mIR mm3u1 PN m30 PO m030 v10 V N M m 1 ^ t I a 00 nv1 Or` TO ON e+1S �N NO IVC �^ vi rvf Epp 1. VR Q^ "m P01 hM �D� N Orv{ �O^ M MP �O^ 00 hl ON m mm m^ n mm m^ 00 OP NP 00 OP NP ON 9 moo ON t0 lA �p 00 of O1 Pm 00 V1 O1 P01 Om Pm vt^ ON �pM 1'Ih PM O!O W 00 00 N v�M {x tmv �u Le N1Am mN OnN nN mvm1 mmm Pmm n^0V1 n^0�I 0^0V1 0^0Vf 00 ^N 0M0 mm OT NpNO PO00 Am NO 00 m MN( Lq Pry PO 0n O V1m V �vP1 p m 1I Ei! N 6dlp'!�i PN 10 N'D MO �p MIA pm O �p m0 mo MO vIOA. 00 IA`r�, �M 00 ^I n0 mm Mj VI m 00 �m e�00 ^IA mO tvi �p �^ ON „i PN ri TD rin OI rP+t mud m0 No PO �o NO No OO �o m0 U>p �O mq 6 O�iE. m M.+ Pm on nim n nO O mm ^P O P Ian, L6 �vj N eM VI �O �G P. . o �^N �G Nm m N� o NO m0 N^ NIV i+1N O m Pm O mN ulry O SON 1 �c N iIA i IA NN OIA ON IAM IA of Om OP OP NIA �m Nuf IOif `A 0m IA ON mOONO0 A 0O^ ON 0MP 'ONNNN 00 0P O H^ P^ NN +Z � { I � Z !MODEL 7110-B 900 ELBOW WITH BASE SUPPORT The Model 7110-B is a ductile iron 900 grooved -end elbow with base support, designed for installation at the bottom of a riser system. An anchor can be placed in conjunction with the base to support the weight of the pipe, coupling and fluid. y sia mmi%m _ O.D. mn/in. _ CF .. .mm/m I_-H^/n V i. T _ m 5 Mt .Abight' mm /a_m/ 80 88.9 108 124 13 14 12.7 99 8.0 3 3500 4.25 4.88 OSO 0.56 5.00 3.88 17.6 100 1143 127 140 13 16 152 121 9.5 4 4500 5.00 550 050 0.62 6.00 4.75 20.9 150 168.3 165 178 16 18 178 140 175 6 6.625 650 7.00 0.62 0.69 7.00 550 385 200 219.1 197 213 22 24 229 191 46.1 8 8.625 7.76 8.38 0.88 0.94 9.00 7.50 10L4 250 273.0 229 248 22 24 229 191 5834 10 10750 9.02 9.75 0.88 0.94 goo 7.50 128S 300 323.9 254 286 25 25 279 241 89.6 12 12.750 10.00 1t25 too 1.00 1L00 � 950 197.1 MODEL 899 END-ALL FITTING The Model 899 End -All fitting is a unique domed end cap fitting available with 1/2", 3/4" and 1" NPT or BSP threaded outlets. Designed as an end of line fitting the End - All features two multi -function bosses which can be used for the direct connection of sprinkler heads, sprigs, drops, drains and or gauges. 1 Nowa.i 5ii. - _ _. Dim'ensions_._h. .. '� yyeight � _ - --'- ' BT - Gi.-&ed X Threaded }.-_ t _.mm rn-� 32 x 15 445 30.1 03 1.25 x 0.5 1.750 1190 0.7 32 x 20 445 30.1 03 125 x 0.75 1750 1190 0.7 32x 25 483 31.8 0.3 1.25 x 1 . 1900 1.250 0.7 40 x 15 44.5 333 0.4 15 x 0.5 1.750 1.313 0.9 40 x 20 445 333 0.4 15 x 0.75 1550 1313 0.9 40 x 25 483 34.9 0.4 15x1 1900 1.375 0.9 50 x 15 445 397 05 2 x 0.5 1.750 1.562 1.1 50 x 20 445 39.7 OS 2 x 0.75 1.750 1.562 11 50 x 25 48.3 413 05 2 x 1 t900 1625 11 65 x 15 445 445 0.6 25 x 05 t750 1.750 1.3 65 x 20 445 44.5 0.6 2.5 x3 4 1.750 L750 t3 65 x 25 463 46.0 0.6 25x1 1.900 1813 t3 tT SHURJOINT® MODEL 7160 END CAP MODEL 7160P END CAP WITH PLUG Nominal - »7160 End Ca 47160P _; {. .Size .Pipe O.D1-5 - - Plug Siie`" � Z-32 422021.25 16600.40 48.30.2t5 1.9000.450 60303 15 2 23750.7 ' 0565 73.00.4 15 25 2.8750.9 05 65 76.10.4 15 25 3.0000.9 0-580 88.9 25 07 15 3 3500 1.00 15 05 100 114.3 25 t0 25 4 4500 too 2.2 1 100 108.0 25 1.1 - 4 4.250 too 2.4 125 1413 25 1.7 25 5 5563 7.00 3.7 1 125 133.0 25 1.7 - 5 5.250 too 37 125 139.7 25 1.7 25 5 5.500 1.00 3.7 1 150 168.3 25 3.0 25 6 1 6.625 1.00 6.6 7 150 159.0 25 23 - 6 6.250 1.00 5.1 30 165.1 25 3.0 25 6 6500 1.00 6.6 7 200 219.1 30 5.5 40 8 8.625 1.18 72.1 1.5 200JI5 216.3 30 4.6 - 8 8.516 1.18 10.1 250 273.0 32 7.0 40 10 70.750 125 15.4 15 250JI5 267.4 32 7.0 -- 10 10.528 1.25 15.4 300 323.9 32 10.0 40 72 12.750 1.25 22.0 t5 300JIS 3185 32 10.0 - 12 12539 t25 22.0 MODEL 7160H DOMED END CAP Shurjoint 7160H end caps are cast of ductile iron and are designed to withstand pressure evenly over the entire spherical surface. The Model 7160H End Cap is designed for use on 10" - 24" mechanical pipeline applications. MODEL 7160T TRANSITION FITTING (Gr X FT) Shurjoint Model 7160T is an ideal transition fitting when a large reduction is required such as 6" x 1", 4" x 1" etc. The 7160T can be used as an alternative to expensive swaged nipples. 1 i Y1�•-C• f ! •4`! 1.� Numin5l Size _ -_•---71601i:.�•:_:�: cPum'_xaxrn7znaeal'' Lr N.,ht -• 50x 25 23.8 02 2 x 1 0.94 0.4 5ox3z 2la 0.2 2x125 0.94 0.4 65x25 23.8 0.4 25 x 1 0.94 0.9 65x32 23.8 03 Is 125 C94 07 65.40 23.8 03 15x15 1 0.94 07 80 x 25 25.4 06 3x1 too 13 80 x 32 25.4 05 3xt25 too LI 80x40 25.4 0.6 3x15 too 13 80 x50 25.4 0.4 3x2. too 0.9 100x 25 2S4 0.8 4.1 too to 100x32 25.4 0.8 4x L25 100 18 100x40 25.4 0.9 4x15 1.00 20 100x50 25.4 oh 4x2 too 13 150x23 25.4 26 6xl too 5.7 150x32 25.4 26 6x1.25 7.00 5.7 150 x 40 25.4 25 6x15 too 55 150 x 50 25.4 25 6 x 2 100 55 O.D.�O_D. '=Domed bid [ap7__K 9/Lbs_.273.0 76.1 5.5 10150 3.00 121 T16 323.9 76.1 7.4 W50 3.00 163 355.6 102 116 14.000 4.00 255406.4 102 14.6 16.000 4.00 32.1 450 457.2 127 205 18 18.000 5.00 45.1 Soo 508.0 152 24-1 20 20.000 6.00 53.9 550 558.8 1 152 44.0 22 22000 1 6.00 97.0 600 609.6 152 345 24 24.000 1 6.00 75.9 M SHURJOINT® MODEL 901 SHORT RADIUS 900 ELBOW MODEL 7111 450 ELBOW MODEL 903 SHORT RADIUS TEE Shurjoint short radius fittings, while primarily designed for fire protection applications, can also be used for general service requirements. The Model K 9 rigid coupling can be used with short radius fittings without the worry of bolt pad interference. Nominal', Pipe: 8901 117111 - k903` Size; O D., SR 90 -Elbow. _.�. 45 Elbow. _ 'sR Strai ht,Tee. _ G_E.(mmJm)s/Lhs, . Ca E.(mm/m) �Ks/Lbs . -C:i E'(mm/m) =Ks/Lbs i. T 50 60.3 70 0.7 51 0.7 70 1.0 2 2375 275 1.5 200 1.5 2.75 22 65 73.0 76 0.9 57 0.9 76 1.3 25 2.875 3.00 2.0 225 20 3.00 2.9 65 76.1 76 0.9 57 1.0 76 1.3 2.5 3.000 3.00 2.0 225 2.2 3.00 2.9 80 88.9 86 1.4 64 13 86 2.0 3 3500 338 3.1 250 29 338 4.4 100 114.3 102 1.7 76 20 102 3.6 4 4.500 4.00 3.7 3.00 4.4 4.00 7.9 125 1397 124 35 83 3.5 124 4.6 5 5500 4.88 7.7 3.25 7.7 4.88 10.1 125 141.3 124 35 83 3.5 124 4.6 5 5.563 4.88 77 3.25 7.7 4.88 10.1 150 165.1 140 5.5 89 4.4 140 8.6 6 6500 550 12.1 3.50 9.7 5.50 18.9 150 168.3 140 5.5 89 4.4 140 8.6 6 6.625 5.50 12.1 350 9.7 5.50 18.9 200 219.1 176 11.0 108 9.0 176 16.5 8 8.625 '6.94 24.2 4.25 19.8 6.94 36.3 MODEL 7110DR DRAIN ELBOW The Model 7110DR is a grooved -end ductile iron cast elbow with an integral V NPT or BSP drain. The 7110DR was primarily designed for, but not limited to, use on fire protection standpipes. MODEL 7127 STANDPIPE TEE The Model 7127 is a grooved -end tee with a 2-1/2" NPT/BSP threaded branch, specially designed for use on fire protection standpipes. --j C-EB NominaLSize L_mm/iii.._ Pipe O.D. t mm/in`_ _ ,inm/m� �m_in/iny imm/ih� :•R-s/Lb's_ 65 73.0 95 70 40 1.3 25 2.875 375 275 157 2.8 65 76.1 95 70 40 13 25 3.000 3.75 275 157 28 80 88.9 108 70 49 2.0 3 3500 4.25 275 1.93 4.4 100 114.3 - 127 70 63 3.0 4 4500 5.00 2.75 2.4B 6.6 150 165.1 165 70 90 7.0 6 6.500 650 275 3.54 15.4 150 1683 165 70 90 7.0 6 6.625 650 1 275 354 15.4 - Nominbl5i:e: T = - - • - Pipe Q.D:� C r Didiensi2n: c-.- N4ig6l�' G-ER• ' m min, O.. FB' =m/In•_-_ , min/in _ Kgr/Lbi� 100 x 100 x65 1143 x 1143 x 73.0 83 1 102 1 3.4 4 x4x25 4.500 x 43M x 2875 325 4.00 7s 150 x 150 x 65 1683 x 1683 x 73.0 83 127 5.1 6x6x75 6.625 x 6.625 x 2875 325 5.00 112 o SHURJOINT® The Shurjoint hole -cut mechanical tee provides a fast and easy mid -point branch outlet without welding. First a hole is cut or drilled at the desired outlet location. The mechanical tee is then positioned so that the built-in locating collar fits within the hole. As the housing bolts are tightened the pressure moulded gasket forms a leak -tight seal. Use of the Shurjoint mechanical tee can eliminate the need for multiple couplings and fittings. Shurjoint offers a full range of mechanical tees: Model7721: Threaded outlet, NPT or BSPT (ISO threads Model 7722: Cut -grooved outlet (machined) Mocle1723: Saddle -Let; Small mechanical tee with threaded outlet, NPT or BSPT (ISO 7-1) pipe threads MECHANICAL CROSS A mechanical cross connection can be made by combining two mechanical tee upper housing segments. While the housing segments must be the same size, the branch outlets can be of the same or differing sizes or configurations. ice, l i 9D TlueededxTbzeaded Groovedx Grooved LhmadedxGcooved Model 7721C Model 7722C Model 7723C Caution: Piping practices require that main and branch connections are at a true 90' angle. Also be certain that the locating collar is securely positioned inside the outlet hole before tightening the housing. When mechanical tees or mechanical crosses are used as transition pieces between two nuns, the tees or crosses shall be assembled prior to making the branch connections. MODEL 723 SADDLE -LET (Small Mechanical Tee) The Model 723 Saddle -Let is the ideal outlet fitting for direct connections to sprinkler heads, drop nipples and or gauges. �IC B No need for welding, just cut or drill a hole at the desired outlet location Position the Saddle -Let so that the locating collar fits _ _ __ within the hole and secure with the U-bolt and nuts. The Saddle- - n T Let comes with a standard black finish or as an option can be supplied electro zinc plated or painted orange. The Saddle -Let allows full bore flow and is pressure rated to 300 psi (20 bar). ' -- Hale Dsa ""-' .'Disriensions.mm/isi:. �' Tak_eeIfCl tr' "' ," I Nominal Size �v1.6 0/e0063-0; t T) �. Boltsize. Boll Toigge. 1 WesgMl �~32xl5 s __A B_. __C m __.. t NMJL6-Ft� 30 53.0 89.0 56.0 35.0 3/8o 20-30 0.4 1.25 x 05 L18 2.08 3.50 2.20 13B L}Bolt 15-22 0.9 32 x 20 30 3.0 89.0 56.0 35.0 3 80 20 - 30 0.4 125x 075 118 2.08 350 2.20 138 Ll-Bolt 15-22 0.9 32 x 30 6.0 89.0 56.0 38.0 3 80 20 - 0 CA 1.25 x1 Lis 210 350 220 150 LFB011 75-22 0.9 40x15 30 55.0 89.0 56.0 35.0 3 Bo 20-30 0.4 1.5 x 0.5 L18 2.16 350 220 138 L}Bdt 15-22 0.9 40x 20 30 55.0 89.0 6.0 35.0 38o 20-30 0.4 15x 0.75 1.78 1616 3.50 2.20 1 138 Li-8olt 15-22 0.9 40x 25 30 58.0 89.0 56.0 38.0 380 10-30 0.4 15 x 1 L78 2.28 _ 350 2.20 150 Ll-Bolt 15- 22 0.9 50 x 1s 30 64.0 98.0 5 .0 ' 420 3 80 20-30 0.4 2x 05 118 251 3.85 2.20 L65 Ll-Belt 15-22 0.9 50 x 20 30 64.0 98.0 56.0 420 3 80 20 - 0 0.4 2x 075 118 .251 3.85 2.20 165 u-Balt 15-22 0.9 50x25 30 7.0 98.0 56.0 45.0 38e 20-30 0.4 2x1 118 163 3.65 2.20 177 LFBolt 15-22 0.9 65 x 15 30 69. 1710 56 0 3.0 80 20-30 0.4 15x05 178 171 437 2.20 200 Ll-Bolt 15-22 0.9 61x20 30 69.0 7110 56.0 SIA 7 20-30 0.4 7S%OJS L18 2.71 437 220 2.00 L}Bolt 75.22 0.9 65x25 30 720 1110 56.0 54.0 380 20-30 OS 25z7 118 283 437 220 2.13 1}Bolt Is 11 SHURJOINT® isAs �Niaia�inraiox "a._® i •jam !. :.W�'a N a NI`I NW �N Ma! �'N t�P .'N a� �M p^. r=m M �r+l rp Vj �M rp u! r�M Wvl Nn1 rDh ^m f�l� ^M Pry r-ra Oa NC M.' (V XI PN �a prN �a Oa NO Nb Na NM nP (V Y1 Nr'i mn rOM Y1N NN va %jP aP ply VP an VP qW a0 aP yj� ON rp'� rOh rjV Nb rp la MP .DM ^`q nuf Ob q'n .b, :N'�M� M\W MW\ N^ MW\ N" N\ M� MW\ M� M nM M nM ^ m 1 Mx nM M nM bl nM nm Ix N nM M nM VI nM N nM M nm V1 nM P nM m nM b1 nm M nM M nM O\ P!' O\ P� O\ P� .OV1 pP P.M .NN 91m pM Om Om NM NM XN XN XN xN XN xX xx xx xx xx xx xx xx I xX xx Xx xx xx xx xx xx xx Xm X"r X"r Xrn X� Xrn Xm Xm XN Xa Xa Xa xa OX OX OX OX OX NN NN N\ N_N ON N_N N4 N_\ N_N N_N N.N N.N N� N_N N\ NN NN N_N 4x . x . x "CW^Wc^W . x NX mX bX .Dx rOX OX OX OX OX ir0,^W •tt�0 'W "W <"W ^,^-<^ < \C^ t !\^ < <�•- < < <W <�W •<<'W <^Wc^cA^W a a a r' m nN M nN M nri N °'m N °gym M ^N M nN m 0 ^N N N °gym N N WM n rD 'Ory n r0 rON n r0 rON W a °'ri W a 61ri OP ^ni n rD 'DN nrp '�ri nrp 'ON M NM Wei m r'! Oa! ^m Na ^< WM �� p0 ^a mO ^o Pro qo OP 0^� nn raga OP, 00 NO rpY .t i, m 1� U NO OR NO NO NO NO WIM\, a WM an •O IMj a WM ah Wn a OP WN OP W"I OP W^I ^W OP m^. ^W OP ro^I ^W OP ro'"! ^W Oa P ^n Oa P ^ri OV P ^ri PY ^n Oa P ^ri Oa P ^N Oa P ^K Oa P ^ri MN rvm WN `r�s rWilO rvd WO '�'o IWIIO no :W/10 rv6 bO no OO NW NW NW NW �Elf �! ^M ^M ^M ^M ^m �M �M ^M ^m ^W �W On ON qP qP qP m 0 0 D0 DO rnN WO rnN N nN NM nN NMN nN nN nN MMNOPPWm n� nN nN Wm Wm PN PM PM Pm mOnNONON PN PN�p $.a �a p� py p� p'1 p� am am p".? a„ am urN M� rnN MN ^y 1".", nN N n n 1Omf°n°rn°'°'°'°'°i�v O ` ^i^v=a^^^i O oJ n tJ0 NO 1�Paa NO P `?�i 00 =Lq=n=H^hr^°'O��OP 00 0 rGa NN ..q rOa N NNNnNnNnM M^ OP N^ MN mo MN Mp PN nN MN Pjv! rnN WN MN a .oN o .oN MP .nN NV rON aO ro� W nN 0 nN NP nN Np nN NP nN n0 nN P WN P mN .GW WM nN mj N mN Mr o,t P� o+M PP O^y OrN RQ ^�a ^C O/nir ^V' OM ^y. n^ .a f 0p ^ vN O WO mO'O 00N p O Oa^ MN WN nu W� nn O p0 Ou PO p0pVPO nN WMv p0 y N ry N:! ��M•. O^ On O^ nNry MNPX NnNmN Mn OWM O aXNNPOMOaON �% .0 cl%I1OX %O XNo^ % %M XON nxX % X Xm X XO %N Xx %X oNN %i XX %X X; Xx % xoX%% XW XoW o°omo°$bOM % X% vN o N o bMWM W WM o O NM Ow N N N N ZW i The Model 7722 Mechanical Tee provides a fast and easy mid -pipe grooved branch outlet. The mechanical tee utilizes ductile iron housings, a grade E gasket and heat - treated carbon steel track bolts and nuts. Housings are Notes: t Hole diameters listed are suggested hole sawdiametem. 25pecial caution 8 required to some exceptional hole sizes shown in 1 1. painted orange or red, or as an option can be supplied hot - dipped zinc galvanized or epoxy coated. Maximum working pressure: 300 psi (20 bar). Gaskets are interchangeable between Models 7721 and 7722. Nom I'Siie Pipe 'f ` Re. a Nch B 4:32, ll Z4013 0 Bolt S e, Weight A _ 36'.,. C,,, ;pi E mm/mC_ ikwi _ __ m/m �.. _ KIF xis 50 X 25 60.3 X 33.4 38 68 40 128 73 M70 X 55 LO 2 X 1 2.375 X 1315 150 268 157 5.04 287 3/8 X 2-1/8 22 50 X 32 60.3 X 42.2 1451 71 40 128 82 M10 X 55 1.0 2 X 125 2375 X 1.660 t U51 2.80 157 5.04 3.22 3/8 X 2-1/1 22 SOX40 60.3 X 48.3 1451 71 40 128 82 M10X55 L2 2 X 15 2.375 X 1.900 1 t751 280 1.57 5.04 3.22 3/8 X 2-1/8 26 65 X 2S. 73.0/76.1 X 33.4 38 75 48 146 73 M12 X 75 1.8 25 X 1 1875/3.000 X1315 15o 295 1.89 5J5 287 1/2 X 3 4.0 65 X32 73.0/76.1 X 42.2 51 79 48 146 82 M12X75 1.7 25 X 1.25 2.875/3.000 X 1.660 200 3.11 t89 575 3.22 1/2 X 3 3.7 65X40 73.0/76.1 X 483 51 79 48 146 82 M72X75 1.9 25 X 1.5 2875/3.000 X 1.900 2.00 3.11 189 5.75 3.22 1/2 X 3 1 4.2 80 X 25 88.9 X 33.4 38 81 56 760 67 M12 X 75 1.7 3 X 1 3.500 X 1315 1.50 3.19 220 6.30 1 263 I 1/2 X 3 37 80 X 32 88.9 X 422 51 89 56 160 88 M12 X 75 1.8 3 X 1.25 3.500 X 1.660 zoo 330 2-20 630 3A6 1/2 X 3 4.0 8OX40 88.9 X 483 51 89 56 160 88 M12X75 t9 3 X 15 3.500 X 1.900 2.00 3-50 X20 630 3.46 1/2 X 3 4.2 soxso 88.9X 60.3 64 97 56 160 101 M12X75 2.2 3X2 3500X 2375 250 3.58 220 630 33B 1/2X3 4.8 100 X 25 114.3 X 33.4 38 94 72 190 67 M12 X 75 20 4 X 1 4.500 X 1315 LSO 3.89 2.83 7.48 263 1/2 X 3 4.4 100 X32 1143 X 42.2 51 99 72 190 85 M12%75 2.1 4 X t2S 4500 X 1,660 zoo 3.89 283 7.48 3.35 1/2 X 3 4.6 100 X 40 114.3 X 483 51 99 72 190 85 M12 X 75 22 4 X 1.5 4500 X 1.900 200 3.89 283 7.48 335 1/2 X 3 4.8 10OX50 1143 X 60.3 64 105 72 190 101 M12X75 2.7 4 X 2 4.500 X 2375 2-50 4.13 2.83 7.48 3.98 1/2 %3 - 5.9 100 X65 114.3 X 73.0/76.1 70 ill 72 190 112 M12X75 3.0 4 X 2.5 4300 X 2.875/3.000 275 4.37 283 7.48 4AO 1/2 X 3 6.6 100 X80 114.3 X 88.9 89 112 72 190 136 M16X90 5.2 4 X 3 4.500 X 3.500 330 4.40 1 2.83 7.48 535 5/8 X 3-1/2 114 125 X 50 139.7/141.3 X 603 64 124 86 236 102 M76 X 90 4.2 S X 2 5500/5563 X2375 250 4.88 339 9.29 4.00 5/8 X 3-1/2 9.2 In X 65 141.3 X 73.0 70 127 86 236 118 M16 X 90 4.2 5 x 25 SS63 X 2.875 225 5.00 339 9.29 4.65 5/8 X 3-1/2 9S 125 X 65 139.7 X 76.1 70 727 86 236 118 M16 X 90 4.3 5 X 25 5500 X 3.000 275 5.00 3.39 9.29 4.65 5/8 X 3-7/2 95. 150 X 32 165.1/1683 X 422 51 127 98 256 93 M16 X US 4.2 6 X 1.25 6300/6.625 X 1.660 2.00 5.00 3.86 10.08 3.66 5/8 X 5-5/16 9.2 150 X 40 165.1/1683 X 483 51 127 98 256 93 M16 X 135 4.3 6 X 15 6500/6.625 X 1.900 200 5.00 3.86 10.08 3.66 5/8 X 5-5/16 95 BOX 50 165.1/1683 X 603 64 732 98 256 101 M16 X 135 4.8 6 X 2 6500/6.625 X 2375 250 5.20 3.86 10.06 3.98 518 X 5-5/16 10.6 BOX 65 168.3 X 73.0 70 140 98 256 118 M16 X 135 5.5 6 X 25 6.625 X 2.875 2.7S 550 3.86 10.08 4.65 5/8 X 5-5/16 12-1 150 X 65 165.1 X 76.1 70 740 98 256 118 M16 X 135 5.5 6 X 25 6500 X3.000 275 550 3.86 10.08 4.65 5/8 XS-5/161 lil 750 X 80 165.1/1683 X 88.9 89 140 98 256 137 M16 X 135 5.6 6 X 3 1 6300/6.625 X 3500 350 550 3.86 10.08 539 518 X 5-5/16 12.3 150 X 100 165.1/1683 X 1143 114 140 98 256 164 M16 X 135 7.0 6 X 4 6500/6.625 X 4500 450 550 3.86 10.08 6.46 5/8 X 5-5/16 15.4 200 X 50 219.1 X 603 1701 166 120 327 104 M20 X 120 5.8 8 X 2 8.625 X 2375 12751 6.54 4.72 1287 3.89 3/4 X 4-3/4 128 200 X 65 219.1 X 73.0/76.1 70 166 120 327 104 M20 X 120 6.0 8 X 25 8.625 X 2875/3.000 2.75 6.54 4.72 1287 4.09 3/4 X 4-3/4 13.2 200 X 80 219.1 X 88.9 89 166 120 327 128 M20 X 120 7.2 BX3 8.62.5 X3-500 350 6,54 4.72 12.87 5.04 3/4X4-3/4 15.8 200 X 100 219.1 X 1143 114. 166 120 327 164 M20 X l20 75 8 X 4 8.625 X 4500 450 fi54 4.72 1287 6.46 3/4 X 4-3/4 765 SHURJOINT® DUCTILE IRON THREADED FITTINGS IN D.I. THREADED FITTINGSARE a, CUL LISTED AND FACTORY MUTUALAPPROVED FOR 50OPSI SERVCE. D.I. PERASTM A 536 GRADE 65-05.12 DIMENSIONS CONFORM TOANSI B16.3 CLASS 150. THREADSARE NPT PERANSIIASME B720.1 ® NOTICE: D.I. FITTINGS HAVE HIGHERTENSILE STRENGTH THEN THAT OF STEEL PIPE, OVER TIGHTENING CAN CAUSE DAMAGE TO PIPE THREADS WHICH MAY CAUSE LEAKAGE. D.I. FITTING SHOULD BE TIGHrENED THREE TURNS BEYOUND HAND TIGHTEN, NO MORE THAT FOUR TURNS. DESCRIPTION D. I. 90 DEGREED ELBOW ...Mee C@US NOM SIZE ITEM '.COCIE 'DIMENSION: tITEM' WEIGH BL'AGK A• B 1" ID90BO606 1.50 1.50 0.62 11/4" ID90BO707 1.75 1.75 0.90 11/2" ID90BO808 1.94 1.94 1.20 2" ID90BO909 2.25 2.25 1.85 DESCRIPTION D. I. STRAIGITT TEE BIM[� a Fmwnn C U-L US NOM, SIZE' ITEM'':CODE IDIMENSION': ITEM . WEIGH BLACK IB 1" lDT060606 1.50 1.50 0.85 1 114" lDT070707 1.75 1.75 1.22 11/2" lDT080808 1.94 1.94 1.55 2" lDT090909 2.25 2.25 2.45 DESCRIPTION D.I. COUPLING uF e"ee C&US A NOM : SIZE ; ITEM CODE' DIMENSION• ITEM, iB6'ACK.'WEIGHT DESCRIPTION D. I. REDUCING 90 DEGREED ELBOW rl uF" C ul US CNOM ITEM CODE 'DIMENSION ITEM -'. SIZE BLACK' ,A-, WEIGH. 'E4- 1X1/2" lD9ORO604 1.26 1.36 0.44 1X3/4" ID90RO605 1.37 1.45 0.52 11/4X1/2" ID90RO704 1.34 1.53 0.64 11/4X3/4" ID90RO705 1.45 1.62 0.72 11/4X1" ID90RO706 1.58 1.67 0.75 11/2X1" ID90RO806 1.65 1.80 0.92 11/2X1114" ID90RO807 1.82 1.88 1.08 2X1/2" ID90RO904 1.49 1.88 1.08 2X3/4" ID90RO905 1.60 1.97 1.24 2X1" ID90RO906 1.73 2.02 1.40 2X11/4" ID90RO907 1.90 2.10 1.52 2X11/2" 1D90RO908 2.02 2.16 1.65 DESCRIPTION D. I. REDUCING COUPLING O l lou Fmee C �L US NOM ITEM CODE DIMENSION ITEM SIZE .BL'QCK A %WEIGH 1X1/2" lDCR0604 1.69 0.39 1X3/4" lDCR0605 1.69 0.53 DESCRIPTION D. I. 45 DEGREED ELBOW z & uFo." 10 US NOM ." SIZE ITEM CODE ICIIMENSIONITEM. WEIGH 1BLQGK" 1" 1DCP0606 1.67 0.40 11/4" lDCP0707 1.93 0.57 1" ID45BO606 1.12 1.12 0.46 11/2" lDCP0808 2.15 0.75 11/4" ID45BO707 1.29 1.29 0.73 2" lDCP0909 2.53 1.15 11/2" ID45BO808 1.43 1.43 0.92 2" 1D45B0909 1.68 1.68 1.50 O SIGMA Piping Products (800) 999-2550 slgmapipingproducts.com DESCRIPTION D. 1. BuSMNG c c OUrsIDEFE A WSDEHFAD A unay.e C uL US FIZE tx3/4 1 1 /4X1 1 1/2X1 1 1/2X1 1/4 2X1 2X1 1/4 2X1 112 ITEM CODE• IO DIMENSN snLE ITEM: BLIACK>. alaimiLL31yk, lDPLG0604 0.75 0.25 1.42 OUT 0.22 lDPLG0605 0.75 0.25 1.42 OUT 0.17 lDPLG0706 0.80 0.28 1.76 OUT 1.28 lDPLG0806 0.83 0.31 2.00 OUT 0.44 lDPLG0807 0.83 0.31 2.00 OUT 0.30 lDPLGO906 0.88 0.41 1.95 IN 0.66 IDPLGO907 0.88 0.34 2.48 OUT 0.72 IDPLGO908 0.88 0.34 2.48 OUT 0.61 DESCRIPTION D. 1. CROSS B B CoUS NOM' SIZE ITEM ;CODE:.DIMENSION" ITEM, EX17VI``..vv 1" 1DX0606 1.50 1.50 0.98 11/4" 1DX0707 1.75 1.75 1.50 11/2" 1DX0808 1.94 1.94. 1.90 2" 1DX0909 2.25 2.25 2.95 1/4xl" 1DX0706 1.58 1.67 1.27 1/2xl- 1DX0806 1:65 -1.80 -1.45 2xl" 1DX0906 1.73 2.02 2.10 DESCRIPTION D. I. CAP A o UL Us MOM ` SIZE ITEM rC M DIMENSION: i1TEM iWEIGH BL'¢GK 1" 1DK06 1.16 0.32 1114" 1DK07 1.28 0.43 1112" 1DK08 1.33 0.60 2" 1DKO9 1.45 0.91 THREADED FITTINGS DESCRIPTION D. I. REDuciNG TEE LE ..nave" C@US NOM;: SIZE ITEM+'.CODE 'DIMENSION' BLACK - 0©` ] lxlxl/2" IDT060604 1.26 1.26 1.36 lxlx3/4" IDT060605 1.37 1.37 1.45 lxl/2xl" IDT060406 1.50 1.36 1.50 lx3/4xl" lDT060506 1.50 1.45 1.50 lxtxl 1/4" lDT060607 1.67 1.67 1.58 lxlxl1/2" lDT060608 1.80 1.80 1.65 1 1/4xlxl/2" lDT070604 1.34 1.26 1.53 11/4xlx3/4" lDT070605 1.45 1.37 1.62 1114xlxl" IDT070606 1.58 1.50 1.67 1114xlxl1/4" lDT070607 1.75 1.67 1.75 11/4xlxl1/2" lDT070608 1.88 1.80 1.82 11/4xl1/41/2" lDT070704 1.34 1.34 1.53 11/4xl1/43/4" IDT070705 1.45 1.45 1.62 11/4xl1/4xl" IDT070706 1.58 1.58 1.67 1 1/4xl 1/4xl 10 l DT070708 1.88 1.88 1.82 11/4xl 1/4x2" IDT070709 2.10 2.10 1.90 1 1/2xlxl/2" lDT080604 1.41 1.34 1.66 11/2xlx3/4" lDT080605 1.52 1.37 1.75 11/2xlxl" lDT080606 1.65 1.50 1.80 11/2x1x11/4" 1DT080607 1.82 1.67 1.88 11/2xlxl1/2" lDT080608 1.94 1.80 1.94 11/2xl1/4xl/2" IDT080704 1.41 1.34 1.66 1 1/2xl 1/4x3/4" IDT080705 1.52 1.45 1.75 11/2xl1/4xl" IDT080706 1.65 1.58 1.80 1 1/2xl 1/4x2". IDT080709 2.16 2.10 2.02 1 1/2xl 1/2xl/2" lDT080804 lAl 1.41 1.16 11/2xl1/2x3/4" lDT080805 1.52 1.52 1.75 11/2xl1/2xl" 1DT080806 1.65 1.65 1.80 1lrZd 10d 19" 1DT080807 1.82 1.82 1.88 11/2xl1/2x2" lDT080809 2.16 2.16 2.02 2x1x2" IDT090609 2.25 2.02 2.25 2x11/4x2" IDT090709 2.25 2.10 2.25 2x11/2xl/2" IDT090804 1.49 1.41 1.88 2xl1/2x3/4" lDT090805 1.60 1.52 1.97 2xl 1/2xl" lDT090806 1.73 1.65 2.02 2x11/2x11/4" lbTo908O7 1.90 1.82 2.10 2xl 1/2xl 1/2" lDT090808 2.02 1.94 2.16 2xl 1/2x2" 1DT090809 2.25 2.16 2.25 2x2xl/2" lDT090904 1.49 1.49 1.88 2x2x3/4" lDT090905 1.60 1.60 1.97 2x2xl" IDT090906 1.73 1.73 2.02 2x2xl 1/4" IDT090907 1.90 1.90 2.10 2x2xl 1/2" lDT090908 2.02 2.02 2.16 2x2x21/2" lDT090910 2.60 2.60 2.39 21/2xW/4" lDT100905 1.74 1.60 2.32 tl,PM, WEIGH 0.64 0.73 0.71 0.76 0.98 1.16 0.82 0.90 1.00 1.08 1.42 0.86 0.92 0.95 1.45 1.75 0.95 1.14 1.17 1.34 1.45 1.05 1.15 1.25 1.90 1.15 1.24 1.30 1.48 1.98 2.15 2.30 1.50 1.62 1.64 1.80 2.00 2.35 1.60 1.68 1.85 2.04 2.18 3.61 2.28 O SIGMA Piping Products (800) 999-2550 sigmapipingprod ucts.com DIMENSIONS AND WEIGHTS (INCHES/POUNDS) Type 40 CG (Standard Welghl Cut Groove) Type 10 RG (Lightweight Rol: Groove) Type 40 RG (Standard Weight RoU Groove) Type 40 MT (Standard Weight Male Thread) Type 40 BW (Standard weight 370 Bevel for welding) �aramosasl P 1 1-4. 1 3- 11440 1 U15 1 0.133 1 .44 1-Ve 1-Vr 3• 1=8 1 1.050 1 0.10 1 .0 V6 1 W-8. a• 1.610 1.900 0.145 .7 2• Y41' 3- 2007 2.275 0.154 A 2-W 2-W W 2A00 2875 0203 1A 3' r- r 3.080 3.500 0216 2.1 4- 14. 4- 4.020 44W 0237 a4 V V`8- 4• 5.047 5.553 n2.se SA e• 6W 4- 0.065 0.0 0280 7.0 6• e• 4' 7.001 8.625 1 0277 10.4 Outlet sizes are available up to 36" O.D. Please call for Details. e NOMINPL OU �Ei A INIAINPL HEM EN 0 6lENeiHO C 6u1LEr 61MENSI6Ns 01PIAEIEA OIPMETER D E iMtKNES F � WFIGHr EAON The hole size should be aiefrdl inside diameterofteomaetpriorto velding HEADER 800-338-8464 • Fax 901324-5943 P.O. Box 80447 • 1083 N. Hollywood St. • Memphis, TN 38108-0447 P.O. Box 80447 • 1083 N. Hollywood St. Memphis, TN 38108-0447 a'etsas ,. 4 OS adang'eoNn`c�Fyvrl;:8le`A o , � i WELD OUTLET 901 Intersection to Header.T. AFM► CARBON STEEL BRANCH OUTLET For Fire Protection and Other Low Pressure Piping Systems THE MOST VERSATILE AND ECONOMICAL METHOD TO ACHIEVE BRANCH OR TEE CONNECTIONS IN THE PIPING INDUSTRY. WELDED THREADED FLANGED AND C 1nOOVED MATERIALS: Highly weldable grade black carbon steel equal to or exceeding the requirements of the American Society for Testing and Materials specifications) our option of the following in single/dual or triple stenciled material/: A-135. A-795, A-53. U.L. / U.L.C. / F.M. WORKING PRESSURE: Figures 40CG / 40RG / 40MT / 40BW up to SOO CWP in PSI Figure IORG up to 300 CWP in PSI Pressures have been established using listed and/or approved couplings and fittings of equal or higher ratings. Hydrostatic test of 2:1 for maximum working pressure and 5:1 forsirength of body. (4: I for 8"). QUALITY ASSURANCE AND INSPECTION: Dimensional integrity is assured with accurate machining, stringent quality control procedures, and sound fabrication techniques. Grooves, threads and bevels are constantly checked for proper alignment and concentricity, uniform depth, taper and degree, as applicable. conforming to established industry standards. ITi 07:N 1►C1'� For identification, each fitting bears the name "ISLAND" or registered trademark along with appropriate figure number and end preparation designation. In addition, the nominal outlet and headersize in inches, and co, :4FM► Indicating listing and approval with recognized testing laboratories. DESIGN: ISLAND weld outlets are designed to provide unobstructed full flow. This is accomplished by making the inside diameter of the low weld volume machine contour precisely fit the outside diameter of the adjoining pipe/ header to be welded. The full penetration weld is made forming a smooth passageway to prevent catching or clogging of foreign matter. Therefore, no special allowances are necessary when utilizing computer hydraulic flow calculations. ISLAND type 40 & 10 weld outlets are manufactured in a wide range of header sizes. Each fitting is manufactured "size on size'. This means the outlet fits exactly on the header to which it is welded, so it is ideal for use with automatic welding machines. FINISH: Fittings are cleaned to bare metal internally and externally and protected with a smokeless rust inhibitor giving a lasting finish to extend shelf life. PACKAGING: For convenience in warehouse handling, storage, and inventory control, ISLAND Figure 40 and 10 fittings are packaged in corrugated cartons; palletized and sealed with shrink wrap plastic. Thread protectors are provided with #40MT to insure quality from factory tojob site. SPECIALS: In addition to brochure listings; black carbon seamless, stainless steel and other materials, sizes up to 36" O.D.; various wall thickness, lengths, shapes, degree of intersection and end preparations are available and can be supplied on special order. Please call for additional information. SPECLLL NOTE: ISLAND type 40 & type 10 outlets are listed and approved to be used with every manufacturers brand of sprinkler pipe. This includes schedules 5, 7, 10, 20, 30, 40 and any other proprietary sprinkler pipe being manufactured. In other words, ISLAND outlets, whether type 40 or type 10 can be welded to any schedule steel pipe available, without limitation to the fitting. SUGGESTED FIRE PROTECTION SPECIFICATION: Welding branch outlet fittings employing cut or roll groove, male thread or buttweld bevel shall be U.L. / U.L.C. listed and F.M. approved conforming to NFPA Bulletin 13, of Domestic Manufacture as produced by ISLAND FITTING COMPANY, Memphis, TN 38108. - `� � �;ti� R�I�ij►1111► SERVICE APPLICATIONS: r • R'I IOtC,+Ic.ON 4. WE , 's d0_ e I IMM 11 ..AL �5.. m`°A NG, (6. IND � U4001N (OWN. M0101 L .'+1.. �Or�711 if •• Good piping practices should always prevail. The designer should always take into consideration design data of other manufacturers' product when used in conjunction with ISLAND fittings, as well as environmental and service factors such as temperature, specific pressures, and external or internal loads. TYLER UNION° 2"13" 4", 6"1 8" 10", 12", 14" 16", 18" DUCTILE IRON C110 FLANGED FITTINGS Sizes 3" thru 12" UL Listed for Fire Main Equipment 20", 24" BENDS Note: Base Bends are on page 33 and 34, reducing and long radius 90" bends are on page 33. 30" 3�1 90° Bends (1/4) 45" Bends (1/8) 221/2' Bends (IA6) 111/,' Bends (1/32) Dimensions Dimensions Dimensions Dimensions Size R A Weight R A Weight R A Weight R A Weight 2 3.0 4.5 14 ... ... ... ... ... ... ... ... ... 3 4 5.5 26 3.62 3 20 7.56 3 22 15.25 3 20 4 4.5 6.5 44 4.81 4 36 10.06 4 35 20.31 4 40 6 6 8 67 7.25 5 57 15.06 5 64 30.5 5 56 8 7 9 115 8.44 5.5 105 17.62 5.5 90 35.5 5.5 90 10 9 11 164 10.88 6.5 131 22.62 6.5 130 45.69 6.5 130 12 10 12 236 13.25 7.5 196 27.67 7.5 194 55.81 7.5 193 14 11.5 14 330 12.06 7.5 245 25.12 7.5 250 50.75 7.5 245 16 12.5 15 478 13.25 8 315 27.62 8 315 55.81 8 315 18 14 16.5 527 14.5 8.5 422 30.19 8.5 402 60.94 8.5 385 20 15.5 18 878 16.88 9.5 485 35.19 9.5 505 71.06 9.5 505 24 18.5 22 1085 18.12 11 730 37.69 11 528 76.12 11 760 30 21.5 25 1755 27.75 15 1355 57.81 15 1385 116.75 15 1395 36 24.5 28 2135 35.00 18 1755 72.88 18 1790 147.25 18 1805 42 27.5 31 3055 42.25 21 2600 88.00 21 2665 177.69 21 2680 48 30.5 34 4095 49.50 24 3580 103.06 24 3665 208.12 24 3695 Tyler Utilities Division • 11910 CR 492 • Tyler, Texas 75706 • (800) 527-8478 02/01/08 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 29 TYLER UNION® N4L11*1 MECHANICAL JOINT C153 DUCTILE IRON COMPACT FITTINGS Sizes 3" thru 12" UL Listed For Fire Main Equipment 90" Bends (1/4) 45' Bends (1/8) 221/s Bends (1/16) 111/4- (1/32) Dimensions Dimensions Dimensions Dimensions Size T A R Weight A R Weight A R Weight A R Weight 3 .34 3.5 2.5 19 2.00 2.41 17 1.50 2.51 15 1.25 2.53 16 4 .35 4.0 3.0 26 2.50 3.56 22 1.75 -3.81 20 1.50 5.12 20 6 .37 6.5 6.0 49 3.50 7.25 39 2.25 6.35 31 1.50 5.12 29 8 .39 7.5 7.0 64 4.00, 8.44 56 2.85 11.80 50 2.06 15.80 45 10 .41 9.5 9.0 102 5.01 10.88 78 3.35 14.35 66 2.32 18.36 59 12 .43 10.5 10.0 129 5.98 13.25 102 3.86 16.90 87 2.56 20.90 82 14 .51 12.0 11.5 214 5.50 12.06 155 3.93 17.25 142 2.59 21.25 136 16 .52 13.0 12.5 273 5.98 13.25 204 3.98 17.50 178 2.62 21.50 157 18 .59 15.5 14.0 411 6.50 12.36 292 7.50 30.19 286 3.00 60.84 283 20 .60 17.0 15.5 519 7.00 13.59 372 8.50 35.19 376 3.50 71.07 374 24 .62 17.0 15.5 721 7.50 14.89 490 9.00 37.69 512 3.50 76.12 487 30 .66 21.50 19.0 930 10.50 9.31 716 6.75 21.36 665 4.75 22.84 600 36 .74 24.50 22.0 1450 11.50 21.73 1110 7.75 26.39 960 5.00 25.38 820 42 .82 29.25 26.7 2205 14.00 27.76 1610 9.00 32.68 1350 6.00 35.54 1180 48 .90 33.25 30.75 2990 15.00 30.17 2090 10.00 27.70 1760 6.50 40.61 1475 *OFFSETS MJ x MJ MJ x PE Dimensions Weights Size D L' L M1xM1 MJxPE 4 6 10 -- 45 -- 4 12 16 -- 55 -- 4 18 22 -- 65 -- 4 24 28 -- 75 -- 6 6 12 17.5 41 54 6 12 18 -- 65 -- 6 18 24 -- 75 -- 6 24 30 -- 85 -- 8 6 13 -- 84 -- 8 12 19 -- 90 -- 8 18 25 100 • Not included in AW WA C153. Tyler Utilities Division • 11910 CR 492 • Tyler, Texas 75706 • (800) 527.8478 2 Union Foundry Company • Box 309 • Anniston, Alabama 36202 • (800) 226-7601 02/01/08 A P O P P P P P P A A A A A N N N N N N O O O O O m x OD x P P x A W x x Q! P OJ P Oo P A W Oo P A W P A W A x W W A N O N O O V G. N 6 6 6 LT In A j y y 6 A A A A A A � JW W W W W W P N N N N N Nj W W W W W Wy�� V V l 0 A C y A. A-?. A.A. w f.1 fJ W to to is is is iow �� V Ga in inAAAAin ������ -tu W A W W E �O V lT A •O V N A •O V N A V !T 0 A A o C 0 a +, O :D W V P 0 O M V P O N O• N A A N P M A A P 0 A A 0 A A A W W 3� O O U� N V� V� N tT tT tN tT tT N� N N N tT O (T U� In W O N to � O O O O O tT tT p O 3'• O O O W Ou Oe Ou p V V V V V P P P P tT tT A A A W p WO 000000000000(n to (T NfT (T OOOOOOOOOOOOOOO On � A A � — — — — — N N U� N N U� A AAA A N N N N N N -+ � d � .O •O W OJ P P P N . 0000000000000000000000000000 to In In fn N O `C~ � ry D� a m p N V P A A W W O OD O N 00 OD lVi i W V P N N • m W V P A N OD A N W V N N O O W •O OD O V V LT P {T fT W W N O m0 V V N W -+ 10 00 O 0 •O o� � N N V U A W W N N ... N N _ -+ -+ -+ N A OD A W 00 A O •O V A W� A N -+ •D O OJ 00 P N N W W N A. A W W O V a. N O P W A : N N N N N N N J N— tT A O OD P lT .O P In W O OD A W o W N�. • W. N P. A W W O b N O V N 0, A. 0 (T O N V� m d: P [T W N W A: � N: 0 �O o s = y n O 3 3 m N 3 x m 1 m m to A 0 W to N m CD A w ya T Z C N r C r 0 r Z C el o o� Ul "m tIi oC ..4 A 1 a Ar- m O ZM CD 00 3 to Z P m N _ 0 o 0,P P P A N N N N N 0 0 0 O m m m P 0,A A W y� % % X X X % % a N m P O m 0, IL m 0' A P A A W O O_ 2 N p. y v (T N N O O N O N 6O 6 6O O N O (T G 6 VI O (T _ D N N N J N N N X __ •� D m (n N N N O 00 00 P :O V P N P A W W -+ m m V� V P (n (n 3 m N 3 f O mmmO = x I 2,. A tP(T N N UN (T A .A A A A ?AA(W 4i Ll 4l W W W C 0J - O AN H O C In (n (n O N � H W N� � N N m P N -+ W -+ •O V (T -' �O V N �O V (T V (n (n A A f'1 O G In (T (T O P A W W A N N o p W m N N m `O O P •O P V O -+ •O N •O N V �O P (n V N •D P �. �� W W•O V T in m K'y AA W W W W W W W W NNNNNNNNNN������ -- ---+- -----+-+-+-+-+ m N P P O 0 A A A A A 0 0 0 0 0 m m m m m P P P A A A A N N N N 0 0 0 m m P P A W p x xx x x x x x X X jx x x x X %_ j Jx x %_ _ X% X %%%www%% A O O O A O P A O m P O m P A N m P A N O P A N O m A N O m P N O m P O m P A m P A P A A W W • A u N •O m V V V V P PP PPPPTOO• PPP P(n tn(n (n in !A (n(n 6 (n (n L� A.� J-W W W W W in'y O N A A A APPP PNN NNN O O O O O� 10 10 10 1ONNNNNE W W W W V V Ut A C PPO�N (n P(T [T (T � (nAUNnNA 0 01V4PVPNN4-V A{n AAAA-1+.A?.A A W W W W W W W W W W W m V P (n V V N •O V (n V N In A A o•N _ ____ 3 00 O ?. m 0 m O N A P N m 0 N A V m 0 N A A (T N `O � A (n 14 A 0 -4 0 V 41 W G O O O G C O C G C C G G O G O O O O O O O O O O G C G O G O O G O G G W V CNN --- N N A W N A W V O O m O N A N P m O N N P m O N N W (n V: 0 N W( n V� O O N A� O O N� O O .O O O G •p^a (nOOt (nCGGOGGOOOOOOOOGGGGOOCOOOOOO(T 6(n (n (n (n (n (T (n (T (n (n O ON PmO � � N(T V V �O (n P(T V O N O N AP�0O N A�0O NA0O N0 O0O m N N : . . . . . . . O O m m A O m m U-A O O 6 (n 6 O (T (T in (n (n (n fn (n (n (n (n (n in (n (n (n 6 (n (n (n N -+ -+ — N — — — — — —� A P m OO W A P U f V W A W (n V O O u O N A V m O N N P m 0 (n P m N P (T O V A Om . . . . . . . . OOOOln OOO in 6O b 6 (T (n O (n (n N in (n (n 66OO OOOOOOOOOO J t nV A c n AA co W W : W N N N y m —— -+ -+ N- — — — — —— O m V V NOD V CNN N W N O NOm V �OOANN W W OOOOPNPPNN(n W W NN-+ N (n O: m(T fT (nNN(nA0 W lnmA(TAO(TP�OOm PNOOAA W V A V ADO W �OPmmm NA V ��T�aO��NON�•0 O-N+m m V mm W NNN W OOOOPP(T P(nAA W W NN-+ UfPAOInOONNO�ONNOlnmmOO �OO OHO W Am��N V V �Nm-+NmPmAPN V W W W N N N_ .N....� N — — — — — — — — — — — — p ONO: NNOOOOONNm�OmP�OO mN(T (TPmNN�OPV V V. N � W �N W NO. NPNPAA W W NN-+ m H N m x V � r M m v c n m 'O r m H m V m X V m H �I PIPE PRODUCTS PVCGRIP Restraint for C900 & IPS PVC Pipe JRPL.02R Series 3500 PVCGRIP Mechanical Joint Restraint For PVC Pipe Only NOMITEM}L - SIZE CODE WTi L P,RIOE 4 PVG04 8.9 40.00 6 PVG06 14 2 8`'S0 . 8 PVG08 17.9 71.70 10 PVG10 27 2 135;60 z 12 PVG12 34.2 142.50 16 ?,PVG16 77 0, i 30500, Mechanical joint restraint that provides 3600 of pipe engagement for restraining action. Sizes 4"-12" for C900 and IPS PVC pipe. Sizes 16" for C905 PVC pipe with Cl outside diameter only. Series 3500 PVCGRIP Mechanical Joint Restraint Packaged With Accessories NQM Ductile Iion,Pip' SIZE CODE } OD DE g SOD , } WT� r PR CE 4 PVGPK04 4.80 P.VGP,.;KT04 4500 12.8 53.70 6 PVGPK06 (i 90 PP PKT06 5 19 9 67 35 8 PVGPK08 9.05 PVGPKT08 8 625 23.9 92.60 10 PVGP.K10 11 10 P�VGPKTIO 10:750 I ? 35 0 ;' 1162 3<8 ,fin ... ........ ..: 4 _1.P s , '7. 12 PVGPK12 13.20 0YGPKTI2 12,Z50 42.1 171.10 16:'y P.VGPK16 ^`:k'sn NiaT-�FiJA ^ •90.0 ,�,, 36100 Contact factory for Custom Packaging vAth longer bolts, Core Blue bolts and nuts or With zinc alloy nuts Tel: (800) 999-3009, (281) 558-3000, Fax: (281) 558-9000 Pages PIPE PRODUCTS JRPL.02R r STARGRIPTm Bolt, Nut and Wedge ZINC ANODE NUT NO SIZE j. ITEM CrT ODE A ��� �I [ }i- N1Ti:j.PRICE L 3/4 ANODE60Z 0.375 4.90 PVCGRIP and ALLGRIP TORQUE - OFF BOLTS NOMfi ITEMrffi SIZE CODE -k?]-1 fft'N _PRICE 4 -10 AGBOLTCS 0.7 5.30 N Page 6" Tel: (800) 999-3009, (281) 558-3000, Fax: (281) 558-9000 PIPE PRODUCTS Adapter Flanges JRPL.02R Flange Drilling ANSI B16.1/ 126 lb. / ANSI B16.5150 lb. Working Pressure - 3" Through 8" 200 PSI/ 10" Through 12" 175 PSI NOM Ducb�.l{e l oo—n Pipe ; � l�f I S+!f jP``�plel �} � 1 1 11' g GOD j f I LF! M�� Of) I1iFflI H� A� J WT i PRICE 31 SF203G 3.96 SF203TG 3 500 59 5.8 26 4 SF204G �' °4 80 SF204TG�`4'500 g a s i� 8 8 35 85 ® 6' SF206G 6.90 S,F206TG ' ? 6 625 12.3 38.56 8' S2D6G' 9 05 S208TG—' 18625 > 191 52 ✓2 10' SF21OG 11.10 SF210TG i 10,760 27.4 96.59 12' SF212G _ ` j 13,20 SF212TG }i 12d750 "_. , 37 0 ' 1,,g Series 400 Adapter Flange for Ductile Iron and Steel Pipe Flange Drilling ANSI B16.1 125 lb. / ANSI B16.5 150 lb. Working Pressure - 4" Through 12" 250 PSI / 14" Through 24" 150 PSI / 30" & 36" 100 PSI L 70 Tel: (800) 999-3009, (281) 558-3000, Fax: (281) 558-9000 Page 7 I I Restrainer for C-900 STAR®PIPE PRODUCTS PVC Pipe to Fittings Series 1000C Restrainers for C 900 PVC Pipe JRPL.02R PRC1004 12 PRC1012 PRC1020 PRC1024 PRC1030 - Sizes 4' through 1T individually packaged and shrink wrapped. C900 PVC Restrainers coated black. T-Bolts/Rods/Hex Nuts: Low alloy steel in accordance with ANSVAVVWA C111/A21.11 Clamping Bolts: SAE J429 GRADE 5 Series 1000CP Restrainers for C-900 PVC Pipe with MJ Accessories 0 S k I �' �` PIP Z_E C 7# AT _` PR CE T L., 4 PRCP1004 16 4.80 36.80 6 PRCP70l)6 21� ` 690 ' 4598 «, r ` a 8 PRCP1008 30 9.05 62.80 10 - PRCP7010ir 12 PRCP1012 51 13.20 117.98 16 PRCP1016 102 17.40 239.00 'PRCP1018 'ti ° ' 120x; 19 50 285 00 ^^ % { z ,b 20 PRCP1020 175 21.60 349.00 280 111! 402 00 30 PRCP1030 453 32.00 PO $Uij 38.30 Sizes 4" through 12" indhAdually packaged and shrink wrapped. Page 8 C900 PVC Restrainers coatepqIpr 800) 999-30099 (281) 558-3000, Fax: (281) 558-90.00 STEEL -Sidewinders SelfIDrilling • Self -tapping W SWOR srrew.r Llcewe w8h remmermu SiyDR led, re1Nnn nm #14SW (11em#1014ed) Sidewinders& Samenys 12" rod STEEL - 1/4" Rod (Horizontal Mount) Use #14S W Nut Driver (Item 4 10 1) Item# Model Screw Minimum Nwmum I Actual Box Qty Weight Case Qty Description Thickness Thickness Shem/Pullout (per 100) 2003 SWD 100 1/4-14z1 .066°-16 go 1/4° 1477# / l6 ga ]00 6.00 1000 407 SWD200 1/4-14x2 .066"-16 ga 1/4- 1477#/16g1 100 6.50 1000 206 SWDR100 1/4.20 .036'-20 go 1/4° 1900#120ga 1 100 6.00 1 1000 STEEL - 3/8" Rod (Horizontal Mount) Use #14S W Nut Drhur (Item #101) Approval Item# MOdcl Screw Description ULTest Loadlh. UIIFM Pi Size Minimum Maximum Actual Thickness Thickness Shear/Pullout Box Qty Weigh (per l00 NFPA 39 SWD10 1/4-14x1 1 1.066'-16 go 1/4' I477#116 ga 100 6.00 'NrPA 40 SWD 15 1/4-14x11/2 oye:fStmvdla_nhle'ddedgn/ger%unnnnmfo'r.SWO70 amg1 S D30 (1='%erigdl) Ien 7j a�re�ron.IYant'On'(yfN elengN,a's�vuiiy 100 7.50 InPA 41 SWD 20 1/4-14x2 100 6.50 ?ZFPA 42 SWD 516 5/16-18xl 1/4 100 7.00 U-?UPA 46 SWDR 11/2" 1/4-20x11/2 1500# 4 12" 237501.25'-1/4' 100 7.25 m.'rurvA 43 SWDR1" 1/4-20xl 1500# 4 1/4' 1900#120 ge Ica Too UL'NPPA 44 SWDR516 5/16-18x11l4 1500# 4 1/4' 2480#/20 ga 9.036'-20ga 100 8.25 MA45SWT15 12-24xl 1/2 12° Ioo 6.25 SHEET STEEL GAUGES Gauge No. 1/4 3116 1 12 1 14 1 18 1 18 1 20 1 22 1 24 26 Decim al Equivalent 1 .25 .188 1 .105" 1 .075' 1 .069' 1 .048" 1 .036" 1 .039' 1 .024" .018" Ultimate Pullout Values - Sammys (average Ibs, ul8rrate) Fastener Steel Gauge Model Dia. Pt. 20 18 16 14 1 12 3116 114 DST 1/4 #3 446# 613# 970# 1145# 1544# 3190# DST 516 5116 #3 457# 568# 1209# 1712# 2422# 3716# TEK 50 #12 #5 487# 699# 9139 1527# 3270# 3593# DSTR 1112" #12 95 3270# 3593# DSTRV 1/4 #3 1510# 0.STR516 5/16 #3 22009 Ultimate Shear/ Pullout Values -Sidewinders (average lbs. ul0rrete) Fastener Steel Gauge Model Dia. Pt. 20 18 16 14 12 3116 1/4 SWD 114 93 1477# SWDRI 112" #12 #5 2375# SWDRP' "i k3 00# 19 190IHi SWDR516 5116 #3 2480# 2480# Aluminum Curtain Wall Extrusion Utimate Pullout Values (average lbs, uM ate) Fastener Thickness Model Dia. Pt. .114 .092 .365 .132 DST 10 1/4 #3 1265# 2750# SWD 10 1/4 #3 1120# 1420# For fastening/anchoring in high vibratory environments, consult local code authorities for accepted anchoring devices Norc: Snmvr m,ar6ernsmlled wlfi apProPri^renuedrivnroro ob.dmnm.mn Page 7 FUNCTION: Designed for attaching hanger rod to the top flange of a beam or Fig. 35Q' . bar joist, where the flange thickness does not exceed 3/4 inch. The BEAM CLAMP- open U design permits rod adjustment. The universal design of the 3/ a Fig. 350 allows it to be used in an inverted position on the bottom flange of a beam as well. FM Sul - UM APPROVALS: Underwriters' Laboratories Listed in the U.S. (UL), Canada (CUL), for all sizes. Factory Mutual Approved for rod sizes 3/s" and 1/2' only. Complies with Federal Specifications A-A-1192A (Type 19) and Manufacturers' Standardization Society ANSI/SP-69 and SP-58 (Type 19). Fig. 350 sized for 3/8 rod can be used in an inverted position (bottom of beam) and follows the same U.S. (UL), Canada (CUL), and Factory Mutual Approvals. Used in this manner the 3/8" Fig. 350 also complies with Federal Specifications A-A-1192A (Type 23) and Manufacturers' Standardization Society ANSI/SP-69 and SP-58 (Type 23) (Approvals are only for Fig. 350 with locknut). MATERIAL: Malleable iron with hardened steel cup point set screw FINISH: Plain or electro-galvanized ORDERING: Specify rod size, finish and figure number. Rod Max. Size Pipe Max. Rec. Wt. Each A B C D E Size Load/lbs. (in lbs.) A% 1 11/z 1% 1/2 4 400 .33 1/z 1 11/x 111/16 1/2 8 500 .34 6/8 11/16 11/8 17/8 % 8 600 .39 3/4 16/16 13/4 2% % 8 600 .63 r/8 16/16 13/4 2% % 8 1200 .60 Note: See MSS ANSI/SP-69 and SP-58 specifications for proper set scre¢o torque values. A Reversible design approved for bottom beam use. PHD Manufacturing, Inc. • 44018 Columbiana -Waterford Road • Columbiana, OH 44408 Toll Free (800) 321-2736 • Phone: (330) 482-9256 9 Fax: (330) 482-2763 • www.phd-mfg.com FUNCTION: Designed for use in pipe hanger assembly. Fig:10' - MATERIAL: Low carbon steel THREADED STUD5; FINISH: Plain Fig15' & 15L MACHINE THREADi H.ANGER.ROD Fig. 15 RIGHT-HAND THREADS Fig.15L RIGHT -AND LEFT-HAND THREADS Fig: 20. & 21 - CONTINUOLTS TH-REAM.- ROT.) Fig. 20* PLAIN Fig.21 ELECTRO-GALVANIZED *AvaLlable in stainleseel. To order, sped04 or 316 and add su SS to figure number. Price on request. ORDERING: Specify rod size, length (B) and figure number. Max. Rec. Rod Load/lbs. Wt. Per Size Inch/Ibs. 650°F 750'F 3/8 x B 730 540 .02 1/2 x B 1350 1010 .04 %x B 1810 1610 .07 3/4 x B 2710 2420 .11 7/8 x B 3770 3360 .14 Available in stainless steel. To order, specify 304 or 316 and add suffix SS to figure number. Price on request. FUNCTION: Designed for use in pipe hanger assembly. MATERIAL: Low carbon steel FINISH: Plain ORDERING: Specify rod size, length (B) and figure number. Rod Thread Max. Rec. Load/Ibs. Wt. Per Size Length Inch/lbs. - 650°F 750°F G %x B 21/3 730 540 .03 1/2 x B 21/z 1350 1010 .06 % x B 21/z 1810 1610 .09 3/4 x B 3 2710 2420 .13 7/a x B 31/a 3770 3360 .17 1 x B 4 4960 4420 .22 FUNCTION: Useful in applications where stud lengths cannot be predetermined. MATERIAL: Low carbon steel ORDERING: Specify rod size, length and figure number. Available in stain- less steel. To order, specify 304 or 316 and add suffix SS to figure number. Price on request. Packaging Max. Rec. 'Per Rod Feet Per Bundle Load/Ibs. Wt. Size Fo6Vlbs. 6 ft. 10 ft. 12 ft. 650°F 750°F 1/4-20 300 500 600 240 210 .12 3/3-16 150 250 240 610 540 .29 1/r13 72 120 144 1130 1010 .54 %-11 48 80 96 1810 1610 .83 3/4-10 30 50 60 2710 2420 1.25 7/e79 24 40 48 3770 3360 1.65 1-8 12 20 24 4960 4420 2.25 12 PHD Manufacturing, Inc. FUNCTION: Designed to provide a means of connecting two lengths of rod with equal diameters. MATERIAL: Low carbon steel FINISH: Plain or electro-galvanized ORDERING: Specify rod size, finish and figure number. Hex Max. Rec. Wt. Each Rod Size Length Width . Load/lbs. in lbs. 1/4 7/8 % 230 .06 % 13/4 3/8 730 .11 '/z 13/4 11/16 1350 .11 % 2% 13/18 1810 .17 314 21/4 1 2710 .28 7/3 21/z 11/4 3770 1 .56 1 23/4 1% 4960 72 Fig.100 STANDARD ROD COUPLING ILI Available in stainless steel. To order, specify 304 or 316 and add suffix SS to figure number. Price on request. FUNCTION: Designed to provide a means of connecting two lengths of rod Fig. 104 with equal diameters. SHORT PATTERN MATERIAL: Low carbon steel ROD COUPLING FINISH: Plain ORDERING: Specify rod size, and figure number. Hex Max: Rec. Wt. Each Rod Size Length_ Width Load/Ibs. (in lbs.) 730 .04 3/8 1350 .06 - FUNCTION: Designed to provide a means of connecting two lengths of rod Fig. 105 with different diameters. REDUCING ROD MATERIAL: Low carbon steel COUPLING FINISH: Plain ORDERING: Specify rod size, and figure number. I Rod Size Length Hex Width Max. Rec. LoaclAbs. Wt. Each in lbs. %X'/4 1 '/z 230 .04 '/z X % 1'/a % 730 .07 %X'/2 11/4 1hs 1350 .14 3/4 X 3/8 21/z 1 1810 .21 7/8 X 3/4 1 23/4 11/4 2710 1.40 PHD Manufacturing, Inc. 23 ADJUSTABLE SWIVEL MR, A GERS 46A • a. FUNCTION: Desiggned for the suspension of non -insulated stationary pipe lines. The marled insert nut that allows a vertical adjustment after uvstallation, is Fig 141 &.141F: _ tapped to NFPA reduced rod size standards. Fig. 141F has a layer of felt 1-' - S WI_V. _ WE separates the pipe from the hanger to reduce vibration and sound. — APPROVALS: Underwriters' Laboratories Listed in the U.S. (UL), Canada (CUL), and _kl 6 HANGER= ' Factory Mutual Approved for sizes %" to 8". Complies with Federal Specifications A-A-1192A (Type 10), and Manufacturers' Standardization Fig. 141 PRE -GALVANIZED Society ANSI/SP-69 and SPSB (Type 10). Fig. 141E PRE -GALVANIZED ORDERING: Specify pipe size and figure number. WITH FELT LINING Pipe Sze Adj. Max. Rec. Wt. Each Size A B C- D E Loadlibs. (in lbs.) 1/2 % 17/e 17/16 23/4 31/16 300 .10 3/4 % 111/16 11/e 21/2 31/16 300 .10 1 % 15/8 1 2112 33/16 300 .10 11/4 % 115/16 11/16 2t3/16 39/,6 300 .11 11/2 % 21/8 11/16 31/e 37/8 300 .11 2 % 27/16 11/e 35/16 43/a 300 .14 2% % 31/16 1% 315/ls 5% 525 .19 3 % 311/,6 1% 48/16 65/ls 525 .23 31/2 % 1 33/4 17/8 45/, 65/8 525 .25 4 31, 43/,6 17/6 51/16 75/16 650 .30 5 11, 45/s 15/6 55/8 8% 1000 .50 6 112 55/8 2114 61/2 913/18 1000 .58 6 112 613/16 27/18 715/16 121/4 1000 .90 Note: If ordering Fig. 141Ffelt lined (arrest size to allow for the this of 31/2" or under, order the next FUNCTION: Designed for the suspension of non -insulated stationary pipe lines. The knurled insert nut, allows for vertical adjustment after installation. Fig.151F has a layer of felt which separates the pipe from the hanger to reduce vibration and sound. APPROVALS: Underwriters Laboratories Listed in the U.S. (UL) and Factory Mutual Approved for all sizes. Complies with Federal Specification A-A-1192A (Type 10), and Manufacturers Standardization Society ANSI/SP-69 and SP-58 (Type 10). ORDERING: Specify pipe size and figure number. Pipe Sze Adj. Max. Rec. Wt. Each Size A B C D E Lodd/Ibs. (in lbs.) 21/2 1/2 23/4 11/4 311/1, 51/8 600 .33 3 1/2 31/s 11/6 4 57/a 600 .35 31/2 1/2 3% 11/2 45/16 6% 600 .37 4 5/8 37/a 11/4 415/,6 71/8 1000 .48 5 % 4% 13/a 5% 81/2 1000 .57 6 3/4 55/,6 2 611/16 101/6 1250 1.06 8 3l4 615/1e 2% 85/,s 1 12% 1 1250 1 1.32 Note: I�ordering Fig. 151F elt lined hangers or pipe sizes of 3'/2" or under, order the next largest size to allow ffor the thickness of the felt lining. 41 is UStm MATERIAL: Low carbon steel Fig_! 151_ & 151F SWIVEL RING HANGER: Fig.151 PRE -GALVANIZED Fig.151F PRE -GALVANIZED WITH FELT LINING MATERIAL: 1 Low carbon steel M> PHD Manufacturing, Inc. 25 t ,1 May 14, 2010 Sprinkler 83a The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9501 Technical Services: 877-3845464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com DESCRIPTION Viking EC/QREC Light and Ordinary Hazard Extra -Large Orifice Sprinklers VK532 and VK534 are thermosensitive spray sprinklers available in several different finishes and temperature ratings to meet varying design requirements. The extra -large orifice produces the flows required to meet Light and Ordinary Hazard density require- ments at lower pressures than standard orifice or large orifice sprinklers. The special deflector is designed to meet Light and Ordinary -Hazard density requirements for specifically listed extended areas of coverage when the required minimum water supply is provided at the sprinkler. Upright Sprinkler VK532 has cULus Listings and as standard and quick response, FM Approvals as quick response; Pendent Sprinkler VK534 has cULus Listings as standard and quick response. The special Polyester and TeflorP coatings can be used in decorative applications where colors are desired. 2. LISTINGS AND APPROVALS cULus Listed: Category VNIV FM Approved: Class 2022 NYC Approved: MEA 89-92-E, Volume 9 Refer to Approval Chart 1 and Design Criteria on pages 83d-e for cULus Listing requirements, and refer to Approval Chart 2 and Design Criteria on page 83f for FM Approval requirements that must be followed. 3. TECHNICAL DATA Specifications: Available since 1993. Viking Technical Data may be found on Minimum Operating Pressure: Refer to the Approval Charts. The Viking Corporation's Web site at Maximum Working Pressure: 175 psi (12 Bar). Factory tested hydrostatically http://www.vikinggroupinc.com. Factory tested hydrostatically to 500 psi (34.5 bar). t50psi bar). The Web site may include a more recent tested Thread size: 3/4" (20 mm) NPT edition of this Technical Data Page. Nominal K-Factor: 11.2 U.S. (161.3 metric}) tMetric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. Glass -bulb fluid temperature rated to -65 "F (-55 "C) Overall Length: Part No. 08687: 2-5/16 (59 mm) Part No. 08340: 2-3/8" (61 mm) Material Standards: Sprinkler Frame: Brass UNS-C84400 Deflector: Brass UNS-C26000 for Sprinkler 08340. Copper UNS-C19500 for Sprinkler 08687 Bulb: Glass, nominal 3 mm diameter Belleville Spring Sealing Assembly: Nickel Alloy, coated on both sides with Teflon Tape Screw: Brass UNS-C36000 Pip Cap and Insert Assembly: Copper UNS-C11000 and Stainless Steel UNS-S30400 For Teflon® Coated Sprinklers: Belleville Spring -Exposed, Screw -Nickel Plated, Pip Cap -Teflon® Coated For Polyester Coated Sprinklers: Belleville Spring -Exposed Ordering Information: (Also refer to the current Viking price list.) Order EC/QREC Light and Ordinary Hazard Extra -Large Orifice Sprinklers VK532 and VK534 by first adding the appropriate suf- fix for the sprinkler finish and then the appropriate suffix for the temperature rating to the sprinkler base part number. Finish Suffix: Brass = A, Chrome-Enloy® = F, White Polyester = M-AN, Black Polyester = M-/B, and Black Teflone = N Temperature Suffix (°F/"C): 1350/570 =A, 155"/68° = B. 175°/79° = D. 200°/93" = E, and 286"/141° = G For example, sprinkler VK532 with a Brass finish and a 155 °F/68 °C temperature rating = Part No. 08687AB Form No. F_051393 Replaces page 83a-f, dated November 12, 2009. (Updated FM Approvals and split the Approval Charts to separate UL Listing requirements from FM Approval requirements.) Sprinkler 83b May 14, 2010 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49068 Telephone: 269-945-9501 Technical Services: 877-3845464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Available Finishes And Temperature Ratings: Refer to Table 1 Accessories: (Also refer to the "Sprinkler Accessories" section of the Viking data book.) Sprinkler Wrenches: A. Standard Wrench: Part No. 05118CW/B (available since 1981) B. Wrench for recessed pendent sprinkler: Part No. 11663W/B•• (available since 2001) "A'/2" ratchet is required (not available from Viking). Sprinkler Cabinets: A. Six -head capacity: Part No. 01724A (available since 1971) B. Twelve -head capacity: Part No. 01725A (available since 1971) 4. INSTALLATION Refer to appropriate NFPA Installation Standards. 5. OPERATION During fire conditions, the heat -sensitive liquid in the glass bulb expands, causing the glass to shatter, releasing the pip cap and sealing spring assembly. Water flowing through the sprinkler orifice strikes the sprinkler deflector, forming a uniform spray pattern to extinguish or control the fire. 6. INSPECTIONS, TESTS AND MAINTENANCE Refer to NFPA 25 for Inspection, Testing and Maintenance requirements. 7. AVAILABILITY Viking Sprinklers VK532 and VK534 are available through a network of domestic and international distributors. See The Viking Corporation web site for the closest distributor or contact The Viking Corporation. 8. GUARANTEE For details of warranty, refer to Viking's current list price schedule or contact Viking directly. Protective Sprinkler Wrench o Shield Flat Figure 1: Standard Sprinkler Wrench 05118CW/B 1-1/2" (38 mm) 2-5/16' (59 roM> 3/4'-/w (20 mr7) NPT Figure 2: Upright Sprinkler VK532 May 14, 2010 Sprinker 83c The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-946-9601 Technical Services: 877-3845464 Fax: 269-8184680 Email: techsvcs@vikingcorp.com TABLE 1: AVAILABLE SPRINKLER TEMPERATURE RATINGS AND FINISHES S rnkle T,e� _erature S nnl ter N urinal p M r u mbient gu b Colo Classific"a i'on Teppera ure atin ' Ceiling Tempera u e 100 -F (38'C) Orange Ordinary 135'F (57 -C) Ordinary 155'F (68'C) 100 -F (38'C) Red Intermediate 175 -F (79'C) 150'F (66 -Q Yellow Intermediate 200'F (93'C) 150'F (65'C) Green High 286 -F (141 'C) 225'F (107 -C) Blue Sprinkler Finishes: Brass, Chrome-Enloy®, White Polyester', Black Polyester', and Black Teflon®' Footnotes ' The sprinkler temperature rating is stamped on the deflector. ] Based on NFPA-13. Other limits may apply, depending on fire loading, sprinkler location, and other requirements of the Authority Having Jurisdiction. Refer to specific installation standards. ' For automatic sprinklers, the coatings indicated are applied to the exposed exterior surfaces only. Note that the spring is exposed on sprinklers with Polyester and Teflon® coatings. For Teflon® coated open sprinklers only, the waterway is coated. - Step 11 the wrf around and pro (Note the orientation of the shield in the wrench,) IN kler Wrench /Baler must be for Installing Sprinkler VK534 '2' ratchet is ed, (not avall- from Viking). Carefully press the wrench upward and turn slightly to ensure engagement with the sprinkler wrench flats. Figure 3: Wrench 11663WIB for Recessed Pendent Sprinkler VK534 Sprinkler 83d May 14, 2010 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49068 Telephone: 269-945-9501 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Sprinkler NPT Thread Size Nominal K-Factor Maximum Water Overall Length Base .Part Number' SIN Working Pressure 9 Inches mm U.S. metric x Inches mm 08687 Upright VK532 3/4 20 11.2 161.3 175 psi (12 Bat) 2-5116 59 08340 Pendent VK534 314 20 11.2 161.3 2-3/8 61 Approval C art 1 (lJL) T�F�" � KEY EGIQREE Li ht an Ordina. Ha 9 rd ELOS rin ers y._Xiappl-cahe Listings and ApprovalS3 Max.5 Sprinkler Maximum Minimum Water Supply Requirements? (Refer also to Design P Criteria on page 83e.) Spacing (L x W) Area per Sprinkler Light Hazard Ordinary Hazard Group I Ordinary Hazard Group II PendentVK5341 Upright VK532 Flow/Pressure Flow/Pressure Flow/Pressure cULuS4 NYC' I cULus' NYC' Standard Response 16 ft. x 16 ft. 256 ft' _ 38 gpm @ 11.5 psi 51 gpm @ 20.7 psi Cix, C1X, C1 Ct (4.9 m x 4.9 m) (23.8 m� (143.9 Umin @ .79 Bar) (193.1 Umin @ 1.43 Bar) D1Y D1Y 18 ft. x 18 ft. 324 @' _ 49 gpm @ 19.1 psi 65 gpm @ 33.7 psi C1X, C1X, Cl Cl (5.5 in x 5.5 m) (30.1 m') (185.5 Umin @ 1.32 Bar) (246.1 Umin @ 2.32 Bar) D1Y D1Y 20 ft. x 20 ft. 400 ft' _ 60 gpm @ 28.7 psi 80 gpm @ 51.0 psi C1X, cix, C1 C1 (6.1 m x 6.1 m) (37.2 m2) (227.1 Umin @ 1.98 Bar) (302.8 Umin @ 3.52 Bar) • D1Y D1Y Quick Response 12 ft, x 12 ft. 144 ft2 _ 30 gpm @ 7.2 psi 39 gpm @ 12.1 psi E1Y - E1 See Footnote 6. (3.7 in x 3.7 m) (13.4 m� (113.6 Umin @ .50 Bar) (147.7 Umin @ .84 Bar) 14 ft. x 14 ft. 196 ft' _ 30 gpm @ 7.2 psi 39 gpm @ 12.1 psi E1Y - E1 See Footnote 6. (4.3 in x 4.3 m) (18.2 m� (113.6 Umin @ .50 Bar) (147.7 Umin @ .84 Bar) 16 ft.x 16 ft. 256 ft' 30 gpm @7.2 psi - - 81Y - B1 See Footnote 6. (4.9 m x 4.9 m) (23.8 m') (113.6 Umin @ .50 Bar) 18 ft.x 18 ft. 324 ft' 33 gpm @8.7 psi _ -' B1Y - 81 sea Footnotes. (5.5 m x 5.5 m) (30.1 m2) (124.9 Umin @ .60 Bar) 20 ft. x 20 ft. 400 ft2 40 gpm @ 12.8 psi, - - A1Y - At See Footnote 6. (6.1 m x 6.1 m) (37.2 m2) (151.4 Umin @ .88 Bar) Approved Temperature Ratings A- 135 °F (57 °C) and 175 °F (79 °C) Approved Escutcheons B - 135 'F (57 °C), 155 °F (68 °C), and 175 "F Approved Finishes X - Standard surface -mounted escutcheons or the Micro- (7s "C) 1 - Brass, Chrome-Enloye, White Poly- fast® Model F-1 Adjustable Escutcheon C -155 °F (68 °C), 175 °F (79 °C), 200 °F (93 °C), ester, Black Polyester, and Black Y - Standard surface -mounted escutcheons or the MicrofasN and 286 °F (141 °C) Teflon® Model F-1 Adjustable Escutcheon, or recessed with the D - 155 "F (68 °C), 175 °F (79 °C), and 200 °F Micromatic®Model E-1 or E-2 Recessed Escutcheon (93 °C) E - 155 °F (68 °C) Footnotes ' Part number shown is the base part number. For complete part number, refer to current Viking price list schedule. ' Metric K-factor measurement shown is when pressure is measured in Bar. When pressure is measured in kPa, divide the metric K-factor shown by 10.0. a This chart shows listings and approvals available at time of printing. Check with the manufacturer for any additional approvals. 4 cULus Listed for use in the U.S. and Canada. 5 Accepted for use, City of New York Department of Buildings, MEA 89-92-E Vol. 9. 6 Meets New York City requirements, effective July 1, 2008. r To determine "Minimum Water Supply Requirement" for areas of coverage where length and width of actual sprinkler spacing are not equal, select the 'Maximum Sprinkler Spacing" from the chart that is equal to or greater than the larger of the actual spacing (length or width) dimensions used. Example: When using 10'-6" x 13'-0" sprinkler spacing, provide the "Minimum Water Supply Requirement" listed in the chart for 14'-0" x 14'-0" spac- ing. For areas of coverage smaller than shown, use the "Minimum Water Supply Requirement" in the appropriate hazard group for the next larger area listed. The distance from sprinklers to walls shall not exceed one-half the 'Maximum Sprinkler Spacing" listed for the "Minimum Water Supply Requirement' used. May 14, 2010 Sprinkler 83e The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9601 Technical Services: 877-384-5464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com Q@SIGN CRITERIA - UL Qjs"o refer to'Appmve Char�1 ) cULus Listina Requirements: EC-ELO Upright Sprinkler VK532 and Pendent Sprinkler VK534 are cULus Listed as indicated in Approval Chart 1 for installation in accordance with the latest edition of NFPA 13 for extended coverage upright and pendent spray sprinklers as indicated below: • The minimum water supplies and maximum areas of coverage shown in Approval Chart 1 are designed to provide the following design densities: 0.10 gpm/ft2 (4.1 mm/min) for Light Hazard densities; 0.15 gpm/ft' (6.1 mm/min) for Ordinary -Hazard Group I densities; 0.2 gpm/Rx (8.1 mm/min) for Ordinary -Hazard Group II densities. • The sprinkler installation rules contained in NFPA 13 for extended coverage upright and pendent spray sprinklers must be followed. • Viking EC-ELO Upright and Pendent Sprinklers are cULus Listed for use in unobstructed construction, and noncombustible obstructed construction consisting of solid steel and/or concrete beams as defined in the latest edition of NFPA 13. • Ceiling slope not to exceed 2/12 (9.5°). Also. Viking _ECOH-ELO Upright Sprinkler VK532 and Pendent Sprinkler VK534 are specifically cULus Listed for Ordinary Hazard Occupancies: • For non-combustible obstructed construction within trusses or bar joists having non-combustible web members greater than 1" (25.4 mm) when applying the 4 times obstruction criteria rule as defined in NFPA 13 under "Obstructions to Sprinkler Discharge Pattern Development". • For installation under concrete tees when installed as follows: 1. The stems of the concrete tee construction must be spaced between 3 ft (0.9 m) and 7 11-6 in (2.3 m) on center. The depth of the concrete tees must not exceed 30 in (762 mm). The maximum permitted concrete tee length is 32 ft (9.8 m). However, where the concrete tee length exceeds 32 ft (9.8 m), non-combustible baffles, equal in height to the depth of the tees, can be installed so that the space between the lees does not exceed 32 ft (9.8 m). 2. The sprinkler deflector is to be located in a horizontal plane at or above 1" (25.4 mm) below the bottom of the concrete tee stems. 3. When the sprinkler deflector is located higher than a horizontal plane 1" (25.4 mm) beneath the bottom of the concrete tee stems, the obstruc- tion to sprinkler discharge criteria requirements of NFPA 13 for extended coverage upright sprinklers applies. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to pages EC1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in accor- dance with the latest edition of Viking technical data, the appropriate standards of NFPA, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. 3/4' (20 mm) NPT Pendent Sprinkler 08340 (VK534) Ceiling Opening Sizel 2-5/16' (581 mm) minimum 2-1/2' (63.5 mm) maximum I) 2' (50.8 mm) Maximum Installed with a standard 1/8' (3,1 mm) surface —mounted escutcheon 2-1/8' (54 rum) A-1/2' (384 mm) Installed with a Microfast Model F-1 Adjustable Escutcheon Figure 4: Sprinkler VK534 Dimensions with a Standard Escutcheon and the Model F-1 Adjustable Escutcheon Sprinkler 83f May 14, 2010 The Viking Corporation, 210 N Industrial Park Drive, Hastings MI 49058 Telephone: 269-945-9601 Technical Services: 877-3845464 Fax: 269-818-1680 Email: techsvcs@vikingcorp.com M) Appro al C aFt2'il P"a KE- Quit Response Exten ed Co erage ELO Upright Spnkler V 532 t�i'T,e For C-1 and HG-2 Occu a ties id:_i 7(.-�Es�.n yeca I Maximum 125..1?S �2iBar W1NP Maximum Sprinkler Maximum Area Refer to Design Criteria below. FM Approval' Spacing (L x W2) per Sprinkler NOTE: FM installation guidelines may differ Upright Sprinkler VK532 At 16 ft. x 16 ft. (4.9 m x 4.9 m) 256 ft2 (23.8 m2) from cULus and/or NFPA criteria. Refer to the Al 18 ft. x 18 ft. (5.5 m x 5.5 m) 324 ft2 (30.1 m2) latest applicable FM Loss Prevention 20 ft. x 20 ft. (6.1 m x 6.1 m) 400 ft2 (37.2 m2) Data Sheets (including 2-0 and 3-26). At Approved Temperature Ratings ' Approved Finishes A- 155 'F (68 -C), 175'F (79 -C), 200'F (93'C), and 2867 (141 'C) t - Brass, Chrome-Enloy®, White Polyester, and Black Polyester Footnotes ' This chart shows the FM Approvals available at time of printing. Check with the manufacturer for any additional approvals. 2 To determine "Minimum Water Supply Requirement" for areas of coverage where length and width of actual sprinkler spacing are not equal, select the "Maximum Sprinkler Spacing" from the chart that is equal to or greater than the larger of the actual spacing (length or width) dimensions used. Example: When using 10'-6" x 13'-O" sprinkler spacing, provide the "Minimum Water Supply Requirement" listed in the chart for 14'-O" x 14'-0" spacing. For areas of coverage smallerthan shown, use the "Minimum Water Supply Requirement" in the appropriate hazard group for the next larger area listed. The distance from sprinklers to walls shall not exceed one-half the "Maximum Sprinkler Spacing" listed for the "Minimum Water Supply Requirement" used. DESIGN MRITERIA - FM (Also refe�"i o A p-` r aI Cha 2 above FM Approval Renuirements: Sprinkler VK532 is FM Approved as a quick response Non -Storage extended coverage upright sprinkler as indicated in the FM Approval Guide for use in occupancy hazard classifications HC-1 and HC-2. For specific application and installation requirements, reference the latest applicable FM Loss Prevention Data Sheets (including Data Sheets 2-0 and 3-26). FM Global Loss Prevention Data Sheets contain guidelines relating to, but not limited to: minimum water supply requirements, hydraulic design, ceiling slope and obstructions, minimum and maximum allowable spacing, and deflector distance below the ceiling. NOTE: The FM installation guidelines may differ from cULus and/or NFPA criteria. IMPORTANT: Always refer to Bulletin Form No. F_091699 - Care and Handling of Sprinklers. Also refer to page EC1-3 for general care, installation, and maintenance information. Viking sprinklers are to be installed in ac- cordance with the latest edition of Viking technical data, the appropriate standards of NFPA, FM Global, LPCB, APSAD, VdS or other similar organizations, and also with the provisions of governmental codes, ordinances, and standards, whenever applicable. Ceiling Opening Sizei 2-1/8' 2 1/8' 2-5/16' (58.7 mm) minimum (54 mm) (54 mm) 2-1/2' (63,5 mm) maximum 1 I 1-1/8' (26.6 mm) 2' (28.6 mm) Minimum (51 mm) Minimum Maximum Mnxi� Installed with a Micromatic Installed with a Model E-2 Model E-1 Recessed Escutcheon Thread -on Recessed Escutcheon Figure 5: Sprinkler VK534 Dimensions with the Model E-1 and E-2 Recessed Escutcheons Form No. F_051393 Replaces page 83a-f, dated November 12, 2009. (Updated FM Approvals and split the Approval Charts to separate UL Listing requirements from FM Approval requirements.) tqCO Fire & Building Products Technical Services: Tel: (800) 381-93121 Fax: (800) 791-5500 Series EC-11 & EC-14 — 11.2 and 14.0 K-factor Extended Coverage (Light and Ordinary Hazard) Upright, Pendent, and Recessed Pendent Sprinklers General Description The Tyco® Series EC-11 and EC-14 Extended Coverage Upright and Pen- dent Sprinklers are decorative glass bulb sprinklers designed for use in light or ordinary hazard occupancies. They are intended for use in automatic sprinkler systems designed in accord- ance with standard installation rules (e.g., NFPA 13) for a maximum cover- age area of 460 ft2 (37,2 m2), as com- pared to the maximum coverage area of 130 ft2 (12,1 m2)for standard cover- age sprinklers used in ordinary haz- ard occupancies or 225 1112 (20,6 m2) for standard coverage sprinklers used in light hazard occupancies. The Series EC-11 and EC-14 Sprin- klers feature a UL and C-UL Listing that permits their use with unob- structed or non-combustible ob- structed ceiling construction as de- fined and permitted by NFPA 13, as well as a specific application listing for use under concrete tees. The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers have been fire tested to compare their per- formance to that of standard coverage spray sprinklers. These tests have shown that the protection provided is equal to or more effective than stand- ard coverage spray sprinklers. IMPORTANT Always refer to Technical Data Sheet TFP700 for the "INSTALLER WARNING" that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation orcause it to operate prematurely. Corrosion resistant coatings, where applicable, are utilized to extend the life of copper alloy sprinklers beyond that which would otherwise be ob- tained when exposed to corrosive at- mospheres. Although corrosion resis- tant coated sprinklers have passed the standard corrosion tests of the appli- cable.approval agencies, the testing is not representative of all possible cor- rosive atmospheres. Consequently, it is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/chemical velocity, should be con- sidered, as a minimum, along with the corrosive nature of the chemical to which the sprinklers will be exposed. WARNINGS The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers described herein must be installed and main- tained in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may Impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or sprinkler manufacturer should be contacted with any questions. Model/Sprinkler Identification Number TY5137 - Upright, 11.2K TY5237 - Pendent, 11.2K TY6137 - Upright, 14.01K' TY6237 - Pendent,14.OK TY5137 is a redesignation for C5137, G1894, and 52510. TY5237 is a redesignation for C5237, G1893, and S2511. . TY6137 is a redesignation for C6137, G1896, and S2610. TY6237 is a redesignation for C6237, G1895, and S2611. Page 1 of 8 DECEMBER, 2007 TFP22O Page 2 of 8 TFP220 WRENCH 3/4" ' ESCUTCHEON PLATE FLAT NPT SEATING SURFACE 1 - Frame 2 - Button 3 - Sealing Assembly 2 4 -Bulb 4 5 - Compression Screw 6 - Deflector* 2-7/16" 3 (61,9 mm) • Temperature rating is UPRIGHT & indicated on deflector PENDENT 1-11/16"Y6- 4 •' Pipe thread m connections per ISO 7/1 can be provided 5 on special request. 1l2" (12,7 mm) NOMINAL MAKE -IN CROSS UPRIGHT . PENDENT SECTION FIGURE 1 SERIES EC-11 AND EC-14 EXTENDED COVERAGE SPRINKLERS 11.2 K-FACTOR (TY5137) UPRIGHT AND (TY5237) PENDENT 14.0 K-FACTOR (TY6137) UPRIGHT AND (TY6237) PENDENT SPRINKLER FINISH (See Note 5) HAZARD TYPE TEMP. BULB LIQUID NATURAL BRASS CHROME PLATED WHITE` POLYESTER LEAD COATED LIGHT Refer to Table B for UL and C-UL Sensitivity Rating and Refer to Table C for FM Sensitivity Rating UPRIGHT K=11.2 (TY5137) PENDENT K=11.2 (TY5237) K=14.0 (TY6237) 135°F/57°C Orange 1, 2, 3"' 4 155°F/68°C Red 175°F/79°C Yellow 1, 2, 4 1, 2, 4 200°F/93°C Green 286°F/141°C Blue REC. PENDENT K=11.2 (TY5237) K=14.0 (TY6237) With Style 30 Escutcheon 135°F/57°C Orange 1, 2, 3, 4 1, 2, 4 N/A 155°° F/68C Red 175°F/79°C Yellow 200°Fl93°C Green 286°F/141°C Blue ORDINARY Refer to Table B for UL and C-UL Sensitivity Rating and Refer to Table C for FM Sensitivity Rating UPRIGHT K=11.2 (TY5137) K=14.0 (TY6137) and PENDENT 011.2 (TY5237) K=14.0 (TY6237) 135°F/57°C Orange 1, 2, 3, 4 1, 2, 3, 4 155°F/68°C Red 175°Ft79°C Yellow 1, 2, 4 200°F/93°C Green 286°F/141°C Blue REC. PENDENT K=11.2(TY5237) K=14.0 (TY6237) With Style 40 Escutcheon 135°F/57°C Orange 1, 2, 4 N/A 155°F/68°C I ed 175°F/79°C Yellow 200°F/93°C Green NOTES: 1.Listed by Underwriters Laboratories, Inc. (UL). 2.1-isted by Underwriters Laboratories, Inc. for use in Canada (C-UL). 3. Approved by Factory Mutual Research Corporation (FM). 4. Approved by the City of New York under MEA 177-03-E. ' 5. Where Polyester Coated or Lead Coated Sprinklers are noted to be UL and C-UL Listed, the sprinklers are UL and C-UL Listed as Corrosion Resistant Sprinklers. *Frame and Deflector only. Listings and approvals apply to color (Special Order). •• Pendent Only. N/A: Not Available TABLE A, LABORATORY LISTINGS AND APPROVALS ---j - - -- --- •p ZED m R••A oa0 M m m mmm x x x AA A xxx A x x x x x x N OZ wA O O O o m m o m m A A A ni m m O� [F w m C m (n C w w C m w C m 3 �gp9 mmo mmo mmo mmo r ry o•N 0 "om ooa oo V ooa ooa m o'^ m m m m m y2 m m o m o a n y y m N N N VI m 41 N N m 5 nn nn o.n nn m� npp zoo zoo I I _O >p; >pA N 2� r v y0 yA Zoo DVA z`00 DAA z00 >pA N 3 my z Z z »> zzz »> zzz >» I I I H 1:3 T G Znn Tr to zzz ZZZ ZZZ zam »D` >D> >» m myv AA zzz »> zzz >>> zzz »> N m m tom On Z Z w »� ZZm DDp �Zm D>p Z Z m »p N nA -n o C) yA Z Z w > Z Z m »p Z Z m »p Z Z w DDp a A rA tN'f 0 nA D (•�Z ZZ w ZZm ZZw Zzw N j Q� »p DDp DDp »p .� .,. OA >Ny Dy Z Z m Z z w z z w Z z w o O DDp »p `DDp »p 9 O 2 Z z m »p Z Z m »p Z Z m »p Z z w »p m T " Z m D o> A o 0 o m m m m o m A A A D y Z �» D x x x No O O x x x x x x x x x mwC wm C, wwC m0C (n mm 0 l 0 M 0 awl 2 m'm ooa oov ooa ooa m y Cm o m p p m] p p0 m ;u;um m m p.17 m m a (mJ ( n (mJ n n n m m m m m m m m n n n n a n 6 6 mIt n �� my A n2 o zOp ZDp zDD III OOQ mo vA TC zmp ZAD ZDA III an zJDq zoo I I I 3C DAv 4r mmm~ Oyn zmm zoo zDD III n�m v y� zmm zoo z0D III py nA �m 41 m mmm mmm mmm DDp 0C% p pp a7pp pp;1 XpA 3� m 2A mmm mmm mmm 0010 ym p.17.'0 p pp Xpp :0."0 x 2a oly mmm mmm wmw Dpp A p p p p p p p p p p p p r mmm mmm mmm "II DOD .Tml p p p ,"0 .'D p ,'0 ."0 ,"0 ,TI ;fl fn Z Z m Z Z m Z Z w Z Z m »p »p »p »p T Page 4 of S Technical Data Approvals The Series EC-11 and EC-14 Ex- tended Coverage Upright, Pendent, and Recessed Pendent Sprinklers are UL and C-UL Listed. (Refer to Table A for complete sprinkler approval infor- mation including corrosion resistant status. The approvals apply to the service conditions indicated in the De- sign Criteria section.) The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers are FM Approved. (Refer to Table A for complete sprinkler ap- proval information including corrosion resistant status. The approvals apply to the service conditions indicated in the Design Criteria section.) The Style 60 Two -Piece Flush Es- cutcheon (Ref. Figure 4) is UL Listed and FM Approved for use with the Se- ries ECA 1 and EC-14 Pendent Sprin- klers. Maximum Working Pressure 175 psi (12,1 bar) Pipe Thread Connection 314 inch NPT Operation The glass bulb contains a fluid which expands when exposed to heat. When the rated temperature is reached, the fluid expands sufficiently to shatter the glass bulb, which then allows the sprinkler to activate and flow water. Design Criteria The Tyco® Series EC-11 and EC-14 Extended Coverage Sprinklers must only be installed in accordance with the applicable UL and C-UL Listing or FM Approval requirements as indi- cated below. Only the Style 30 or 40 Recessed Escutcheon isto be usedfor recessed installation, as applicable (Ref. Table A, B, and C).. UL and C-UL Listing Requirements 1. The Series EC-11 and EC-14 Sprin- klers may be used for the coverage areas shown in Table D, based on maintaining the minimum specified flow rate as a function of coverage area and hazard group for all of the sprinklers in the design area. Discharge Coefficients K = 11.2 GPM/psi112 2. (161,3 LPM/bartr2) K = 14.0 GPM/psis/2 (201,6 LPM/bar'12) Temperature Ratings 135°F/57°C to 286°F/141°C Finish Sprinkler: Refer to Table A Recessed or Flush Escutcheon: White Coated, Chrome -Plated, and Brass Plated Physical Characteristics Frame ............. Bronze Button .... ...... Bronze Sealing Assembly . Beryllium Nickel w/Teflont Bulb ... . Glass (3 mm dia.) Compression Screw .... . . ............ Bronze Deflector ............ Brass Patents U.S.A. Patent Numbers 5,366,022; 5,579,846; 5,584,344; 5,609,211; 5,862,994; and 5,865,256. The Series EC-11 and EC-14 Sprin- klers are permitted to be used with unobstructed or non-combustible obstructed ceiling construction as defined and permitted by NFPA 13. For example: Unobstructed, combustible or non- combustible, ceiling construction with a deflector to ceiling/roof deck distance of 1 to 12 inches (25 to 300 mm). Obstructed, non-combustible, ceil- ing construction with a deflector lo- cation below structural members of 1 to 6 inches (25 to 150 mm) and a maximum deflector to ceiling/roof deck distance of 22 inches (550 mm). 3. The Series EC-11 and EC-14 Sprin- klers having been specifically tested and listed for non-combustible ob- structed construction are permitted to be used within trusses orbarjoists having non-combustible web mem- bers greater than 1 inch (25.4 mm) when applying the 4 times obstruc- tion criteria rule defined under "Ob- structions to Sprinkler Discharge Pattern Development". 4. The minimum allowable spacing be- tween the Series EC-11 and EC-14 TFP220 Sprinklers, to prevent cold solder- ing, is 8 feet (2,4 m) for upright sprin- klers and 9 feet (2,7 m) for pendent sprinklers. 5. The Series EC-11 and EC-14 Sprin- klers are to be Installed in accord- ance with all other requirements of NFPA 13 for extended coverage up- right and pendent sprinklers. For ex- ample: obstructions to sprinkler dis- charge, obstructions to sprinkler pattern development, obstructions to prevent sprinkler discharge from reaching hazard, clearance to stor- age, etc. UL and C-UL Specific Application Listing Requirements For Installation Under Concrete Tees The Series EC-11 and EC-14 Ex- tended Coverage Upright and Pendent Sprinklers (TY5137, TY5237, TY6137 & TY6237) have a UL and C-UL Spe- cific Application Listing for use under concrete tees when installed as fol- lows: The stems of the concrete tee con- struction must spaced at less than 7.5 feet (2,3 m) on center but more than 3 feet (0,9 m) on center. The depth of the concrete tees must not exceed 30 Inches (762 mm). The maximum permitted concrete tee length is 32 feet (9,8 m); however, where the concrete tee length ex- ceeds 32feet (9,8 m),non-combus- tible baffles, equal in height to the depth of the tees, can be installed so that the space between the tees does not exceed 32 feet (9,8 m) in length. 2. The sprinkler deflectors are to be located in a horizontal plane at or above 1 inch (25,4 mm) below the bottom of the concrete tee stems. 3. When the sprinkler deflectors are located higher than a horizontal plane 1 inch (251,4 mm) beneath the bottom of the concrete tee stems, the obstruction to sprinkler dis- charge criteria requirements of NFPA 13 for extended coverage up- right sprinklers applies. FM Approval Requirements The Series EC-11 and EC-14 Ex- tended Coverage Sprinklers are to be installed in accordance with the appli- cable Factory Mutual Loss Prevention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard (non -storage and/or non-flam- mable or combustible liquid) occupan- cies. Information provided in the FM TFP220 2-718" DIA 1/2t1/8" (73,0 mm) 112" (12,7 mm) (12,7t3,2 mm) 2.1/4" DIA. 114" (6,4 mm) FACE OF (57,2 mm) SPRINKLER 1/8" FITTING (3,2 mm) MOUNTING SURFACE MOUNTING PLATE CLOSURE 1-3/8" 34,9 mm) 1-1/8" (28,6 mm) FIGURE 2 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER, WITH TWO-PIECE 1121NCH TOTAL ADJUSTMENT STYLE 30 RECESSED ESCUTCHEON 2-7/8" DIA. 5/8t1/4" (73,0 mm) 3/4" (19,1 mm) (15,936,4 mm) 2-1/4" DIA. 1/4" (6,4 mm) FACE OF (57,2 mm) SPRINKLER 1/8" FITTING (3,2 mm) MOUNTING MOUNTING SURFACE PLATE CLOSURE 1-3/8" (34.9 MM) 7/8" (22,2 mm) FIGURE 3 SERIES EC-11 AND EC-14 RECESSED PENDENT SPRINKLER ASSEMBLY WITH TWO-PIECE 3141NCH TOTAL ADJUSTMENT STYLE 40 RECESSED ESCUTCHEON Page 5 of 8 Loss Prevention Data Sheets relate to, but are not limited to, hydraulic design, ceiling slope and obstructions, mini- mum and maximum allowable spac- ing, and deflector -to ceiling distance. These criteria may differ from UL and/or NFPA criteria, therefore the de- signer should review and become fa- miliar with Factory Mutual require- ments before proceeding with design. Installation The Series EC-11 and EC-14 Sprin- klers must be installed in accordance with the following instructions: NOTES Do not install any bulb type sprinklerif the bulb is cracked or there is a loss of liquid from the bulb. With the sprinkler held horizontally, a small air bubble should be present. The diameter of the air bubble is approximately 1116 inch (1,6 mm) for the 135°F/57°C to 3132 inch (2,4 mm) for the 286°F/141 °C temperature ratings. A 314 inch NPT sprinkler joint should be obtained with a minimum to maxi- mum torque of 10 to 20 ff.lbs. (13,4 to 26,8 Nm). Higher levels of torque may distort the sprinkler inlet with conse- quent leakage or impairment of the sprinkler. Do not attempt to compensate for in- sufficient adjustment in an Escutcheon Plate by under- or over -tightening the Sprinkler. Readjust the position of the sprinkler fitting to suit. Step 1. The sprinkler must be installed with the deflector parallel to the mount- ing surface. Pendent sprinklers must be installed in the pendent position, and upright sprinklers must be in- stalled in the upright position. Step 2. After installing the Style 30, 40, or 60 mounting plate (or other escutch- eon, as applicable) over the sprinkler pipe threads and with pipe thread sealant applied to the pipe threads, hand tighten the sprinkler into the sprinkler fitting. Step 3. Wrench tighten upright or pen- dent sprinklers using only the W-Type 3 (End A) Sprinkler Wrench. When in- stalling the pendent sprinkler with Style 30, 40, or 60 Escutcheon, wrench tighten the sprinkler using only the W-Type 22 Sprinkler Wrench. The wrench recess of the applicable sprin- kler wrench (Ref. Figure 5 and 6) is to be applied to the sprinkler wrench flats (Ref. Figure 1). Page 6 of 8 _ 2-7/8' DIA. (73,0 mm) 2-1/4" DIA. (57,2 mm) FACE OF SPRINKLER FITTING: 3/8' (9,5 mm) ABOVE TO 1/8" (3,2 mm) BELOW MOUNTING SURFACE ESCUTCHEON PLATE SEATING SURFACE: 1/4" (6,4 mm) ABOVE TO 112" (12,7 mm) BELOW MOUNTING SURFACE; 3/4" (19,1 mm) TOTAL ADJUSTMENT INTERNAL DIMENSIONS OF STYLE 60 ESCUTCHEON ACCOMMODATE CLASS 150 MALLEABLE / IRON REDUCING SPRINKLER FITTING MOUNTING 1/8" SURFACE CLOSURE 3/4° NPT 2-5/16" 58,7 mm) AOUNTING 1-13/16" 06,0 mm) PLATE FIGURE 4 SERIES EC-11 AND EC-14 PENDENT SPRINKLER ASSEMBLY WITH 314 INCH TOTAL ADJUSTMENT STYLE 60 TWO-PIECE FLUSH ESCUTCHEON Care and Maintenance The Tyco® Series EC-11 and EC-14 Sprinklers must be maintained and serviced in accordance with the follow- ing instructions: NOTE Before closing a fire protection system main control valve for maintenance work on the fire protection system that it controls, permission to shut down the affected fire protection systems must be obtained from the proper authori- ties and .all personnel who may be affected by this action must be notified. Sprinklers that are found to be leaking or exhibiting visible signs of corrosion must be replaced. Automatic sprinklers must never be painted, plated, coated, or otherwise altered after leaving the factory. Modi- fied sprinklers must be replaced. Sprinklers that have been exposed to corrosive products of combustion, but have not operated, should be replaced if they cannot be completely cleaned by wiping the sprinkler with a cloth on by brushing it with a soft bristle brush. Care must be exercised to avoid dam- age to the sprinklers - before, during, and after installation. Sprinklers dam- aged by dropping, striking, wrench twist/slippage, or the like, must be re- placed. Also, replace any sprinkler that has a cracked bulb or that has lost liquid from its bulb. (Ref. Installation Section). Frequent visual inspections are rec- ommended to be initially performed for corrosion resistant coated sprinklers, after the installation has been com- pleted, to verify the integrity of the cor- rosion resistant coating. Thereafter, annual inspections per NFPA 25 should suffice; however, instead of in- specting from the floor level, a random sampling of close-up visual inspec- tions should be made, so as to better determine the exact sprinkler condi- tion and the long term integrity of the corrosion resistant coating, as it may be affected by the corrosive conditions present. The owner Is responsible for the in- spection, testing, and maintenance of their fire protection system and de- vices in compliance with this docu- ment, as well as with the applicable standards of the National Fire Protec- tion Association (e.g., NFPA 25), in addition to the standards of any other authorities having jurisdiction. The in- stalling contractor or sprinkler manu- facturer should be contacted relative to any questions. Automatic sprinkler systems should be inspected, tested, and maintained by a qualified Inspection Service in accord- TFP220 "FITTING SIDE" TOWARDS SPRINKLER FITTING WRENCH RECESS (END "A") FIGURE 5 W-TYPE 3 SPRINKLER WRENCH WRENCH - RECESS r ; 4 , WRENCH HEX FIGURE 6 W-TYPE 22 RECESSED SPRINKLER WRENCH ance with local requirements and/or national codes. TFP220 Page 7 of 8 GROUPI GROUPII LIGHT HAZARD ORDINARY HAZARD ORDINARY HAZARD 0.10 GPM/FT2 0.15 GPMIFT2 0.20 GPM/FT2 DESCRIPTION AREA GPM PSI GPM PSI GPM PSI TY5137 (K=11.2) UPRIGHT 14 x 14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 TY5237 (K=11.2) PENDENT 14 x 14 - - 30 7.2 39 12.1 16 x 16 30 7.2 39 12.1 51 20.7 18 x 18 33 8.7 49 19.1 65 33.7 20 x 20 40 12.8 60 28.7 80 51.0 TY6137 (K=14.0) UPRIGHT 14 x 14 N/A NIA - - - - 16 x 16 NIA NIA 39 7.8 51 13.3 18 x 18 N/A NIA 49 12.3 65 21.6 . 20 x 20 N/A NIA 60 18.4 80 32.7 TY6237 (K=14.0) PENDENT 14 x 14 - - - - - - 16x16 37 7.0 39 7.8 51 13.3 18 x 18 37 7.0 49 12.3 65 21.6 20 x 20 40 8.2 60 18.4 80 32.7 1 ft. = 0.3048 m 1 ft2 = 0.093 m2 1 gpm=3.785 1pm 1 psi = 0.06895 bar l gpm/ft2=40.74 mm/min TABLE D FLOW CRITERIA FOR UL AND C-UL LISTING OF SERIES EC-11 AND EC-14 SPRINKLERS Limited Warranty Products manufactured by Tyco Fire & Building Products (TFBP) are war- ranted solely to the original Buyer for ten (10) years against defects in mate- rial and workmanship when paid for and properly installed and maintained under normal use and service. This warranty will expire ten (10) years from date of shipment by TFBP. No warranty is given for products or com- ponents manufactured by companies not affiliated by ownership with TFBP or for products and components which have been subject to misuse, improper installation, corrosion, or which have not been installed, maintained, modi- fied or repaired in accordance with ap- plicable Standards of the National Fire Protection Association, and/or the standards of any other Authorities Having Jurisdiction. Materials found by TFBP to be defective shall be either repaired or replaced, at TFBP's sole option. TFBP neither assumes, nor authorizes any person to assume for it, any other obligation in connection with the sale of products or parts of prod- ucts. TFBP shall not be responsible for sprinkler system design errors or inac- curate or incomplete information sup- plied by Buyer or Buyer's repre- sentatives. In no event shall TFBP be liable, in contract, tort, strict liability or under any other legal theory, for incidental, indirect, special or consequential dam- ages, including but not limited to labor charges, regardless of whether TFBP was informed about the possibility of such damages, and in no event shall TFBP's liability exceed an amount equal to the sales price. The foregoina warranty is made in lieu of anv and all otherwacraulie3 ex,- This limited warranty sets forth the ex- clusive remedy for claims based on failure of or defect in products, materi- als or components, whether the claim is made in contract, tort, strict liability or any other legal theory. This warranty will apply to the full ex- tent permitted by law. The invalidity, in whole or part, of any portion of this warranty will not affect the remainder. Page 8 of 8 TFP220 Ordering Procedure When placing an order, indicate the full product name. Please specify the Sprinkler Identification Number (SIN), quantity, and temperature rating. Re- fer to the Price List for complete listing of Part Numbers. Contact your local distributor for avail- ability. Sprinkler Assemblies with NPT Thread Connections: Specify: (specify SIN), (specify K-Fac- tor), (specify temperature rating), (specify Pendent or Upright) Extended Coverage Sprinkler with (specify fin- ish), P/N (specify - from Table E, where applicable). Recessed Escutcheon, Two -Piece : Specify: Style (30 or 40) Two -Piece Recessed Escutcheon with (specify material or finish'), P/N (specify). 'Refer to Technical Data Sheet TFP770. Flush Escutcheon, Two -Piece: Specify: Style 60 Two -Piece Flush Es- cutcheon with (specify finish'), P/N (specify). 'Refer to Technical Data Sheet TFP778. Sprinkler Wrench: Specify: W-Type 3 Sprinkler Wrench, PIN 56-895-1-001 Specify: W-Type 22 Recessed Sprin- kler Wrench, P/N 56-665-7-001 PIN 51 - AAA - B -CCC AAA= 893 (for TY5237 K11.2 Pendent) AAA = 894 (for TY5137 K11.2 Upright) AAA = 895 (for TY6237 K14.0 Pendent) AAA = 896 (for TY6137 K14.0 Upright) B = 1 (for Natural Brass) B = 3 (for White [RAL9010])' B = 4 (for White Polyester) B = 7 (for Lead Coated B = 9 (for Chrome Plated) CCC = 135 (for 135°F/57°C) CCC = 155 (for 1550F/680C) CCC = 175 (for 175°F/79°C) CCC = 200 (for 200°F/93°C) *Eastern Hemisphere sales only. TABLE E PART NUMBERS FOR EC-11 AND EC-14 SPRINKLERS © 2007 TYCO FIRE & BUILDING PRODUCTS, 451 North Cannon Avenue, Lansdale, Pennsylvania 19446 So ♦ A LVES 319MU ONO ❑ The AGF Manufacturing Co., Inc. Model 1000 has been designed to provide both the Test Function and the Express Drain Function In a multistory installation. ❑ Complies with all requirements of NFPA-13, NFPA-13R, and NFPA-13D ❑ Positive shut off ❑ Single Handle ❑ Tapped for Pressure Gauge a Tamper Resistant Orifice permanently Installed ❑ Available with all required Orifices o Orifice size noted on Indicator plate ❑ Lightweight and compact ❑ 300 PSI Rating ❑ Integral tamper resistant sight glasses visit us an the Intemet ❑ Full range of sizes from 3/4' to 2" at U� MODEL 1000 Soo psi FM L TMDMNQD 3/47 1 ° . 1 1 /4" 1 1/2° 2° r7►RiTila�9 FRONTVIEW/HORIZONTAL INSTALLATION ORIFICE SIZE AVAILABLE - 3/6, 7/16. 1/2. 17/32. ELO(5/8)0, ESFR(3/4)' DIMENSIONS - INCHES I FROM BRANCH 51RW EL PROVIDIN E D TO DRAIN SSTRREEETEL PIPE TO DRAIN j FOR RIGHT HAND/STRAIGHT INSTAL AMON APPROVALS: ❑ UL and ULC Usted L7 FM Approved except 314P O NYC RD. of S&A CAL. NO.72D-87-SM ❑ CA. State Fire Marshall SIIE A B C D. E F G H 3/411 of 1116" nm 12& 1 1hr 37.681"m 2 31167 m6,9 3 B/6 " 9323 m 3 31g7 83.6,mm 1 13f16" d5 W n 4 91W 117.12mm 41318 11 162A2mm „ 61ha„ Inmm 1 1/2" 37A6mm 2 3/14" 5546mm 3 E/g" 9321mn 3 31B" 63A mm 1 134, 45AOmm 4 9ne 117.12mm 6 34, 16242mm 1 T/ 4' rJ /I6" 13T.70mm 1 itim" 4, , 2 glib" 6536mm 4 1/4" 108A5mm 3 Sim" Mum 1 1511d' 50A9mm tJ 9116" IMA = 5 112" 19226mm 7/ 1 il2 6 ?h? 163A8mm 1 13/16" 4VAMM 3 114" 5IA0mm 5 Ilm" 127mm 3 7AP 99.1&nm 2 a/3" 6a9Tmm 8 Ile M&6WM 10 7i5" 2734anm 2,I 6 71le 1673&nm 1 131.ze L_a . 3 1/4" 6150mm 5 V16" 127mm 3 7JS" 99.1 2 S/S.. 66AX a Ile 206ASmm 10 7fe , 2736pTm The Reliable Automatic Sprinkler Co., Inc 525 N. MacQuesten Parkway Mount Vernon, NY 10552 Phone 800.431.1588 www.reliablesprinklercom MADE IN USA MATERIAL LIST' PART: MATERIAL: HANDLE ' STEELSTEM ROD BRASS BOD BRPOrRJLE VALVE SEAT IMPREGNATSDTEFLON INDICATORT'LATE STEEL HANDLE LOCK SPRING STEEL JOB NAME: _ ARCHITECT: _ ENGINEER: — CONTRACTOR: I I 41WAFER CHECK VALVES Ul. LISTED FM APPROVED is% FIeNGPLI Waist Cheok Vafvea are designed to bo compact, easy to handle and take minimum apses In Inelaliaiton between iwo you standard Ranges, An "O° Ring Seal provides leak free seal behveen two flanges as well as insuring a resiileni seat surraco seal which is enhanced by a stainless sleet torsion sprIn They are FM Approved as ant(waler hammer Check Valves for Ilre pump service only. se Commonly used any pleaused s alr$ppna tive clasurie check valve is0needed, They are designed for lout Action loss. Slzssl g", 8" and e° gl. l.leled/FM Approved 2e0Iha, WOG (spoolfy Sarvlos ttotber than cold water) 100Hydrostalio rested UuMila (roll Body Bronze Clapper and seat Rtng ,a, Ring seats Stainless steel spring closing Approved by the New York City Board of Standards and Appeals Under CalendorNo, 1e7•e4•SA, *The 4" slzo is provided With 112" pipe plug in drain port as standard configuration. (See below) 90WBD 4" only With street elbow and 112" ball drip valve. Slid A e ' 0 0 SHIP W1; (LB•9j QUAN. ,PERoTN. 4' A?8 4,003 sea 8 Is 1 g• a7s 6.06 8.60 4.5 fs 1 a' s.75 7.s0 ton sA 2a f 4' Water Check has been desfgned with the seat angled to provide 1/2 NPT tapping below seal to accommodate a ball • drip potenUell freezing such as In tailie deparlm 41 olpconn2c1101). is sed to 0' and a, Straight Seat No Tapping. LINED ® am APPROVED A.W.W.A Standard C509 n-4; --I to size of bolts 4571 Standard 4071 with Post Plate (3" - 12") 3 Sid. drilling A-21.11 VALVE SIZE At4- C D: E F G H Weight* 2 8-1/4 2.50 4-1/2 10-7/8 2-5/8 7-1/4 2 38 2-1/2 -------- - ---------------- ------------------------ 3 B-1/2 2.50 7-3/4 12-3/8 4-5/8 10 3 63 4 9-1/2 2.50 9-1/8 14-3/4 4-3/4 10 4-1/4 85 6 10 5 2.50 11-1/8 19 6-3/4 12 1 6-1/4 128 8 10-1/2 5-1/4 2.50 13-3/4 22-1/2 6-3/4 14 8-14 200 10 12 6 2.50 15-3/4 2-6-1/2-8-3/4 18 10-1/4' 309 12 13 6-1/2 2.62 18 30 8-3/4 18 12-1/4 471 *Add 16# for Indicator Post Plate (3"-12" only) 2"-12" MUELLER@ T 2360 RESILIENT WEDGE Mueller Co. 12,19 GATE TAPPING VALVE - M.J. X FL. ENDS Rev. 5-08 Dimensions Dimension* Nominal size 2" 3" 4" 8" 81, 10" 12" A 9.88 12.38 14.19 18.00 21.50 25.50 29.62 R 6.00 7.50 9.00 11.00 13.50 16.00 19.00 D 2.97 3.97 5.00 7.00 9.00 11.00 13.00 1 � 0.16 0.18 0.18 0.25 0.25 0.25 0.25 M 4.46 4.73 6.24 6.75 7.75 8.52 7.25 W (bolt circle diameter for FL) 4.75 6.00 7.50 9.50 11.75 14.25 17.00 N 6.25 7.50 9.12 11.12 13.38 15.68 17.94 B (number and size of holes for FL) 4-.75 4-.75 8--.75 8--.88 8--.88 12-1.00 12-4.00 Q (bore) 2.30 3.30 4.30 6.30 8.30 10.30 12.30 FF 855 8.99 11.91 13.00 14.62 15.95 15.24 O (number and size of holes for M3) 4-.75 4-.75 4-.88 6--.88 6--.88 8--.88 8--.88 00 (bolt circle diameter for M3) 4.75 6.19 7.50 9.50 11.75 14.00 16.25 Turns to open 8 11 14 20.5 26.5 33 38.5 Weight* - 42 69 118 163 1260 1401 530 * All dimensions are in inches. All weights include accessories are in pounds and approximate. March 4, 1999 Check Valve 803 a 8 VIIUNGA SWING CHECK VALVE 1. PRODUCT NAME Viking Swing Check Valve Model D-1: 2-1/2" (65 mm) Available since 1992. Model G-1: 3" (80 mm), 4" (100 rum), 6" (150 mm), and 8" (200 mm) Available since 1994. 2.MANUFACTURER The Viking Corporation 210 N. Industrial Park Road Hastings, Michigan 49058, U.S.A. Telephone: (616) 945-9501 (877)384-5464 Fax: (616)945-9599 e-mail: techsvcs@vikingcorp.com 3. PRODUCT DESCRIPTION The Viking Swing Check Valve is a gen- eral purpose rubber -faced check valve approved for use in fire -service sys- tems. The Swing Check Valve is manufar, tured with a ductile iron body, brass seat, and a rubber -faced clapper assembly, hinged to a removable access cover for easy inspection and maintenance. The valve may be installed vertically or horizontally. For availability of flanged - flanged and grooved -grooved options, refer to Table 1. Tapped openings (with plugs) and gauge connections are pro- vided on both the inlet and ouflet cham- bers of the valve. 4.TECHNICAL DATA For listings and approvals, see the approval chart below. Rated to 250 psi (1724 kPa) waterwork- ing pressure. Factory tested hydrostatically to 500 psi (3 447 kPa). Standard flanged connections ANSI B16.42 Class 150 (Mates with ANSI Class 125 and Class 150 flanges). Systems with water working pres- sures above 175 psi (1 207 kPa) may require extra -heavy pattern fit- tings. Viking Swing Check Valve flanges are Ductile Iron ANSI B16.42 Class 150 with a maximum water working pressure of 250 psi. ANSI B16.42 Class 150 flanges are not compatible with ANSI Class 250 or Class 300 flanges. To mate the Viking Swing Check Valve with ANSI Class 250 or Class 300 flanges, use the grooved-In- let/grooved-outlet style installed with listed grooved/flanged adapt- ers of the appropriate pressure rat- ing. For piping with grooved con- nections, the grooved-tn- let/groovedoutlet style Swing Check Valve may be Installed with listed grooved couplings of the ap- ANSI/AW WA C606 Tapped Bosses: Two 1/2" (15 mm) NPT: Model D-1: 2-1/2"(65 mm) Model G-1: 3"(80 mm) and 4"(100 mm): Two 3/4" (20 mm) NPT: Model G-1: 6" (150 mm) and 8" (200 rum) Viking Swing Check Valve Approval Chart 1 2 F YC3 Yes Yes Yes Yes 1 IIL listed Guide No. HMER 2 nsted by underwriters Lebonaledes Inc. for use In Canada 3 Accepted for use, City of New York Depadmenlof BwlSngs, MEN 89.92_E, Vol. XI. Material Standards: (Refer to Figure 1 on page 803 c.) 5. FEATURES 1. Ductile iron body for less weight a extra strength. 2. Rated to 250 psi (1 724 kPa) wa working pressure. nd ter Table 1 Size Inlet Outlet Friction Slippin Part Valve Type Type Lass• Weight No. 2-12" Eft 161bs, (65 mm) Groove Groove (1,8 m) (7 kg) 0.i4` 97C 3' (80 rum) Flange Flange Not Available 3' 10ft. 20 lbs. (80 mm) Groove Groove (3,1 m) (9 kg) 08536 4' 13R 47Its. (100 mm)j Flange I Flange (4 0 m) (21 kg) 08538 4" 13 ft. 27lbs. (100 mm) Groove Groove (4,0 m) (12 kg) 08539 6' 20 ft. 75lbs. (150 mm) Flange Flange (6,0 m) (34 kg) 08542 6' 20 ft. 51 lbs. (150 man) Groove Groove (6,0 m) (23 kg) 11143 8" 23 sc. 135lbs. (200 man) Flange Flange (70 m) (61 kg) 08546 8' 23 ft. 106 lbs. (200 mm) Groove Groove (7,0 m) (48 kg) 08647 • Expressed in equivalent length of schedule 40 pipe based on Hazen & Williams formula: C=120. Viking Swing Check Valves are available out- side of North America with Flanges drilled according to European PN 10 specifications or Table Especifications. Contact manufacturer for availability. 3. Rubber -faced clapper hinged to ac- cess cover for quick removal and easy servicing. All moving parts can be serviced without removing the valve from the installed position. 4. With the cover/clapper assembly re- moved, the clapper rubber replace- ment requires removal of only one screw. 5. Can be installed vertically or horizon- tally. 6. AVAILABILITY AND SERVICE The Viking Check Valve and accesso- ries are available' through a network of domestic, Canadian, and international distributors. Seethe Yellow Pages of the telephone directory fora local distributor (listed under "Sprinklers -Automatic - Fire") or contact The Viking Corporation. Viking technical data may be found on The Viking Corporation's Web site at htlip:/Amew.vikingoorp.com. The Web site may Include a more recent edition of this technical data page. 7.GUARANTEES For details of warranty, refer to Vik ng's current list price schedule or contact The Viking Corporation directly. Form No. F_102688 Replaces page 803 a-d, dated March 10,1998 (updated clapper screw length). Check Valve 803 b March 4, 1999 NIKINGO SWING CHECK VALVE B. OPERATION (Referto Figure Ion page 803 a) Flow through the Viking Swing Check Valve lifts the rubber-gasketed clapper (8, and 9) off the seat (12) to enter the sprinkler piping. When flow through the valve stops, the clapper (8) closes quickly. The rubber gasket (9) forms a tight seal against the brass water seat (12), trapping pressure above the clap- per and preventing reverse flow from sprinkler piping. 9. INSTALLATION The Swing Check Valve must be in- stalled in an area not subject to physical damage. When corrosive atmospheres and/or contaminated water supplies are present, it is the owner's responsibility to verify compatibility with the Check Valve and associated equipment. Prior to installing the valve, thoroughly flush the water supply piping to verify that no foreign matter is present. The Check Valve may be installed in the vertical position with direction of flow up, or in the horizontal position with the ac- cess cover up. Systems with water working pressures above 175 psi (1 207 kPa) may require extra -heavy pattern fittings. Viking Swing Check Valve flanges are Ductile Iron ANSI B16.42 Class 150 with a maxi- mum waterworking pressure of 250 psi. ANSI B16.42 Class 150 flanges are not compatible with ANSI Class 250 or Class 300 flanges. To mate the Viking Swing Check Valve with ANSI Class 250 or Class 300 flanges, use the grooved- inlet/grooved-outlet style installed with listed grooved/flanged adapters of the appropriate pressure rating. For piping with grooved connections, the grooved- inlet1grooved-outlet style Swing Check Valve may be installed with listed grooved couplings of the appropriate pressure rating. Hydrostatic Test: The Check Valve is manufactured and listed for use at a maximum water work- Ing pressure of 250 psi (1 724 kPa). The valve is factory tested at 500 psi (3 447 kPa). Check Valves may be hydro- statically tested at 300 psi (2 069 kPa) and/or 50 psi (345 kPa) above the nor- mal water working pressure, for limited periods of time (two hours), for the pur- pose of acceptance by the Authority Having Jurisdiction. If air testing is re- quired, do not exceed 40 psi (276 kPa) air pressure. 10. INSPECTIONS and TESTS NOTICE: The owner is responsible for maintaining the fire -protection system and devices in proper operating condi- tion. The Viking Swing Check Valve must be kept free of foreign matter, freezing con- ditions (when used on wet systems), corrosive atmospheres, contaminated water supplies, and any condition that could impair its operation or damage the device. It is imperative that the system be in- spected and tested on a regular basis. The frequency of the Inspections may vary due to contaminated water sup- plies, corrosive water supplies, and cor- rosive atmospheres. For minimum maintenance and inspection require- ments, refer to the National Fire Protec- tion Association's pamphlet that de- scribes care and maintenance of sprin- kler systems. In addition, the Authority Having Jurisdiction may have additional maintenance, testing, and inspection re- quirements which must be followed. WARNING: Any system maintenance which involves placing a control valve or detection system out of service may eliminate the fire -protection capabilities of that system. Prior to proceeding, no- tify all the Authority Having Jurisdiction. Consideration should be given to em- ployment of a fire patrol in the affected areas. 10-A Five -Year Internal Inspection internal inspection of Check Valves is recommended every five years unless inspections and tests indicate more fre- quent inspections are required. Refer to Figure 1 on page 803 c. 1. Notify the Authority Having Jurisdic- tion, remote station alarm monitors, and those in the area affected thatthe system will be taken out of service. Consideration should be given to em- ployment of a fire patrol in the af- fected areas. 2. Close the water supply Main Control Valve, placing the system out of serv- ice. 3. Open.the main drain. If necessary, open the system test valve to vent and completely drain the system. 4. Use the appropriate wrench to loosen and remove the cover screws (14), and remove the cover/clapper assem- bly (2-11). 5. Inspect the water seat (12). Wipe away all contaminants, dirt, and min- eral deposits. Do not use solvents or abrasives. 6. Inspect the cover/clapper assembly (2-11) and the cover gasket (13). Test the hinged clapper (8) for free- dom of movement. Renew or replace damaged or wom . parts as required. Caution: NEVER apply any lubricant to seats, gaskets, or any internal operating parts of the valve. Petroleum -based grease or oil will damage rubber compo- nents and may prevent proper opera- tion. 7. When Internal inspection of the Check Valve is complete, perform step 6 of paragraph 11. VALVE MAINTENANCE to re -install the cover/clapper assembly (2-11). 11. VALVE MAINTENANCE (Refer to Figure 1 on page 803 c.) 1. Perform steps 1 through 5 of para- graph 10-A FIVE-YEAR INTERNAL INSPECTION. 2. To remove clapper rubber (9): A. Use the appropriate wrenches to loosen and remove the button - head socket screw (11), hex nut (6), sealing washer (7), and rub- ber retainer (10). B. Remove the clapper rubber (9) for inspection. If the clapper rubber shows signs of wear, such as cracking, cuts, or excessively deep grooves where the rubber contacts the water seat, replace the rubber. 3. To re -install clapper rubber (9): A. Place the clapper rubber(9) overthe center hub of the rubber retainer (10). B. Position the retainer (10) (with rub- ber in place) against the clapper (8) as shown in Figure 1. C. Replace and tighten the button - head socket screw (11), sealing washer (7), and hex nut (6). The sealing washer (7) and hex nut (6) must be located on the top side of the clapper as shown in Figure 1. Do not over -tighten. 4. To remove clapper (8), and/or hinge pin (4): A. Removethe hinge pin retaining rings (5), to free the hinge pin (4) for removal. After the hinge pin (4) is removed, the clapper (8) can be removed. 5. To re -Install clapper (8), and/or hinge pin (4): (continued on page 803 d) March 4, 1999 Check Valve 803 c SIZE A B C D E F• G"• 2-1/2" (65mm) 9- (228,6) 4-1/2" (114,3) 2-5/8" (66,7) 2" (50,8) 2" (50,8) FIg-Fig Not Available 3" 9-1/2" 4-3/4" 2-3/4" 2" 2" rig-FIg (80mm) (241,3) (12D,7) (69,9) (50,8) (50,B) Not Available 4" 10-5/8"5-3/16'3-3/8" 2-1/8" 2-1/4" 9" 15/16" (100mm) (269,9) (131,8) (85,7) (54,0) (57,2) (228,6) (23.81) 6' 13-5/B" 6-3/4" 4-3/8" 2-1/4 " 2-1/4" 11" 1" (150mm) (34fi,1) (171,5) (111,1) (57,2) (57,2) (279,4) (25,4) 8" 17" 8-3/4" 5-3/e" 2-1/2" 2-7/B" 3-1/2" 1-1/B" (200mm) (431,8) (222,3) 136,5) (63,5) (73,0) (342,9) (28,58) A d 8" 1 otured with soul Dimensions shown in parentheses are millimeter. " For availability of Flanged -Flanged or Grooved -Grooved options, refer 1a Table 1. +• f tured flan as * � � 4 , 6 an va Yes are mono a le g thickness C, Dimension Indicates thickness of flange of bolt holes. Figure 1 F*� Viking Swing Check Valve Item Part Numbers No. Req'd 2-112" 3" 4" 6" 8" Description Material " „ No. (65�) (8gmm) (100mm) (150mm) (200mm) 2-112 3 4 6 8 1 -- - - - - Body .Ductile Iron, AS A536 (65-45-12) 1 1 1 1 1 2 09944 09945 09946 09947 09948 Cover Assembly E-Coated HSLA Steel, A715 and Stainless Steel, UNS-S30400 1 1 1 1 1 3 None Bushing Lubricom 189 R on 2 2 2 2 0 4 05355A 05355A 4900A 04991A 05334A Cla Der Hinge Pin Stainless Steel, UNS-S30400 1 1 1 1 1 5 n5445A n.5445A 5445A 09445" 05369A Hinae Pin Relainina Rina Stainless Steel, UNS-S15700 2 2 2 2 2 6 :. Clapper Hex Jam Nut 3/8"-16 UNC Stainless Steel, UN5-53U4UU u I 1 I l I U _I Clapper Hear Jam Nut 12"A3 UNC Stainless Steel, UNS-S30400 0 0 0 1 7 ISealinqWasher EPDM and Stainless Steel 1 1 1 1 g 1 Clapper Teflon Coated HR Steel, UNS-G1018 1 1 1 1 9 05360B 05348B 6109E 05801B 08075 Clapper Rubber EPDM 1 1 1 1 10 05361B 08552 61103 08553 08076 Clapper Rubber Retainer Stainless Steel UNS-S30400 1 1 1 1 ° - - H.H.C. Screw #10-24 UNCx 1/2" 127mm L . Stainless Steel, UNS-S30400 1 0 0 0 --- Screw, Button Head, Socket 3-24 UNF x12"(12,7)Lg. 18 SStainless Steel, UNS30400 0 1 1 0 ' 10308 Screw, Button Head, Socket, 112"-20 UNF x 314" 19,0 mm L . Stainless Steel, UNS-S30400 0 0 0 1 _ 10686 Screw Button Head, Socket, 112%20 UNF x 718" (22,2 mm) Lg. Stainless Steel, UNS-S30400 0 0 0 0 12 Seat Brass, UNS-C84400 1 1 1 1 13 05354B 05354BI04649BI 04992E 05339C Cover Gasket SBR Rubber 1 1 1 1 01517A 01517A 01517A - ., .. , - H.H.C. Screw 318°-16 UNC x 3(4° 19.0 mm L . Steel, Zinc Plated 4 4 6 0 14 _ 04993A H.H.C. Screw 12-13 UNC x7/8" 222 mm L . Steel, Zinc Plated 0 0 0 6 01922A H.H.C. Screw Steel, Zinc Plated 0 0 0 0 _ 58"-11 UNCx1-1W (31,Bmm)Lg. 1/2" 15 mm NPT Pipe Plu Steel 15 3/4' 20 mm NPT Pie Plug Steel - Indicates part is not available fromThe Viking Corporation. Indicates part is available in a Sub-Assemblyonly-see Sub -Assembly list below. Item Nos. 2-112" 3" 4" 6" 8" SUB -ASSEMBLIES 2-11 09939 09940 09941 1 09942 1 09943 Cover/Clapper Assembly 3,6-11 05499B 08554 01555 08556 08521 Clapper Assembly 6'�; I 06343A 1 08558 1 08559 08560 08525 Clapper Rubber Kit Check Valve 803 d March 4, 1999 NIKINGO SWING CHECK VALVE A. Verify that the clapper rubber (9) is in good condition and that it is properly installed. B. Position the clapper (8) with the elongated hinge holes aligned be- tween the holes of the hinge bracket welded inside the cover (2). The system (top) side of the clapper (8) must face the direction indicated by the flow arrow stamped inside the cover (2). C. Insert the hinge pin (4) through the holes at one end of the hinge as- sembly. Continue to push the hinge pin (4) through the holes at 'the remaining end of the hinge assembly. D. Re -install the hinge pin retaining rings (5). 6. To re -install cover/clapper assem- bly (2-11): A. Verify that cover gasket (13) is in position and in good condition. B. Slide the cover/clapper assembly (2-11) into the Check Valve so that the clapper rubber (9) con- tacts the water seat (12). C. Replace the cover screws (14). Use the appropriate wrench to cross -tighten all screws to the torque value shown in Table 2 for the valve used. Do not over - tighten. Table 2 Torque Values for Viking Swing Check Valve Cover Screws Size Size Torque Valve Screw Values (5 mm) 3/8'-16 H.H.C. 2,63 kg m (80 m) 3/8'-16 H.H.C. 19 Nibs 2.63 kg m (100 mm) 3/8'-16 H.H.C. 2.63g m 150 m tl2'-13 H.H.C. 6.23 g-m (200 mm) 5/8%11 H.H.C. 129kg-m Replaces page 803 a-d, dated March 10;1668 Form No. F 102688 (updated clapper screw length). ES-A-3000SS Series 3000SS A M E S Double Check Detector Assemblies FlRE&WATERWORKS 1! n Sizes: 21/2" —12" (65 — 300mm) Features • Patented Cam -Check Assembly valve provides low head loss • Short lay length is Ideally suited for retrofit installations • Stainless Steel body is half the weight of competitive designs reducing installation and shipping cost • Stainless steel construction provides long term corrosion protection and maximum strength • Single top access cover with two -bolt grooved style coupling for ease of maintenance • No special tools required for servicing • Compact construction allows for smaller vaults and enclosures • Furnished with W x a/a" bronze meter (gpm or cfm) • Detects underground leaks and unauthorized water use • Maybe installed horizontal or vertical "flow up" position Available Models Suffix: LG - without shutoff valves Series 3000SS Double Check Detector Assemblies are designed for use in accor- dance with water utility non -health hazard containment requirements. It is manda- tory to prevent the reverse flow of fire protection system substances, i.e., glycerin wetting agents, stagnant water and water of non -potable quality from being pumped or siphoned into the potable water supply. Specifications A Double Check Detector Assembly shall be installed on fire protection systems when connected to a potable water supply. Degree of hazard present is determined by the local authority having jurisdiction. The main valve body shall be manufac- tured from 300 Series stainless steel to provide corrosion resistance, 100% lead free through the waterway. The double check detector assembly consists of two independently operating, spring loaded check valves, two UL, FM, OSY resilient seated gate valves, and bypass assembly. The bypass assembly consists of a meter (cubic ft. or gallons), a double check including shutoff valves and required test cocks. Each cam -check shall be internally loaded and provide a positive drip tight closure against reverse flow. Cam -check includes a stainless steel cam arm and spring, rubber faced disc and a replaceable seat. There shall be no brass or bronze parts used within the cam -check valve assembly. The check valve seats shall be of molded thermoplastic construction. The use of seat screws as a retention method is prohibited. All internal parts shall be accessible through a single cover on the valve assembly. The valve cover shall be held in place through the use of a single grooved style two -bolt coupling. The bypass line shall be hydraulically sized to accurately measure low flow. The bypass line shall consist of a meter, a small diameter double check assembly with test cocks and isolation valves. The bypass line double check valve shall have a single access cover, two independently operating modular poppet check valves, and top mounted test cocks. The assembly shall be an Ames 3000SS. Materials OSY - UUFM outside stem and All internal metal parts: 300 Series stainless steel, Main valve body: 300 Series yoke resilient seated gate valves stainless steel, Check assembly: Noryly Flange dimension in accordance with CFM - cubic feet per minute GPM - gallons per minute meter AW WA Class D. Noryl• is a registered trademark of General Electric Company. Job Name Contractor Job Location Approval Engineer Contractor's P.O. No. Approval Representative Ames product specifications in U.S. customary units and metric are approximate and are provided for reference only. For precise measurements, please contactAmes Technical Service. Ames reserves the right to change or modify product design, construction, specifications, or materials without prior notice and without incurring any obligation to make such changes and modifica- tions on Ames products previously or subsequently sold. www.amesfirewater.com Pressure — Temperature Standards Temperature Range: 33OF -140OF (50C - 600C) ASSE 1048, AW WA C510-92, CSA 1364.5, UL 1469 Maximum Working Pressure: 175psi (12 bars) Approvals Capacity UL Classified (OSY only), FM (sizes 21/2"- 10', OSY only) For 12" approvals consult factory. Flow curves as tested by Underwriters Laboratory UL FM ppfl55E per UL 1469, 1996. *Rated flow **ULTested 2 APp aved kPa psi 21/2" (65mm) * ** 83 12 69 10 55 8 41 6 28 4 14 2 0 25 50 100 150 200 250 300 350 400 450 500 525 ppm 95 190.380 570 760 950 1140 1330 1520 1710 1900 1995 Ipm 16 fps „ 4.6 mps MIRP �..----� �--, rMM �m �������� I�i� �MM MM •, :, , ., 1 1 , , 1 •il 1.1 MMMMMMMMIMMIN MMMMEIMMIN 15 4.6 kPa psi 4" (100mm) 103 15 83 12 62 9 41 6 21 3 0 50 100 150 200 250 300 350 400 450 500 550 600 650 700 750 ppm 171 380 570 760 950 1140 1330 1520 1170 1900 2090 22802470 2660 2850 Ipm 5 10 15 Ips 1.5 3 4.6 mps kPa psi 83 12 62 9 41 6 21 3 Will Ipm fps rips kpa psi * 103 15 83 12 62 9 41 6 21 3 a 0 100 200 300 400 500 .600 700 800 900 10001100 1200 1M INU I= OPm 380 760 1140 15201900 2280 26603040 3420 38004180 4560 49405320 5700 Ipm 5 10 15 fps 1.5 3 4.6 mps S" (200mm) ** 0 250 500 750 1000 1250 1500 1750 2000 2250 2500 9Pm 950 1900 2850 3800 4750 5700 6650 7600 6550 9500 Ipm 5 10 15 Ips 1.5 3 4.6 mps 1011 (250 mm) yy 0 250 500 750 1000 1250 1500 1750 950 1900 2850 3800 4750 5700 6550 5 1.5 T)impncinnc — Wpio'}1t kPa psi 12" (300 mm) 875 National Drive • Suite #107 • Sacramento, CA 95834 • Phone: 916-928-0123 • Fax: 916-928-9333 ES-A-3000SS 0311 © Ames Co. 2003 Printed In U.S.A. 9pm Ipm Ips mps 9pm Ipm Ips mps Brass Ball Drip Valve Description The solid brass ball drip is a "ball' type check valve. When properly installed, the internal ball rests in the 10WE most area of the valve body allowing for proper drainage of moisture accumulation. Upon system pressurization, tl internal ball is "pushed" into the small end of the ball drip closing the opening. When system pressure is removed, ball returns to its original position. One of the most common uses is on the dry side of the Fire Department Connection valve. This use helps keep moisture from accumulating inside the Fire Department Connection. Designed for horizontal installation only. Installation Proper installation of the brass ball drip can be accom- plished with standard piping installation tools. Make sure the threads are clean and free from burs and debris. Apply a thread sealant suitable for the materials being joined such as PipeFit, PipeFitAS or PTFE hand tight. Finish tightening with a pipe wrench up to one full turn. Do not over tighten. Over tightening may dam- age threads and ball drip. Finish piping to allow for proper drainage. Valve opens by force of gravity only. Do not use with more than tape. When using a paste type 1 ft. column of water (water sealant, make sure to brush the sealant deep into the root of the threads. Thread the ball drip into female threads 02008 Fire Protection Products, Inc (FPPI) pressure) on the ball check. Use only in the horizontal position. body Specifications. the Type: Straight Pattern Material: Bddy: Brass Ball: Brass Standard Finishes: Rough Brass Adjustnieht Range: Y<" x%" MNPT x'%" MNPT W x %' MNPT Fire Protection Products, Inc F P P 10 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1' 800 344-1822. 1 800 3443775 fax • www.fppi.com 1 /2"-2" IPS Angle Globe Valves, U L/U LC Listed* 300 psi Fire Protection Products, Inc. 6241 Yarrow Dr., Suite A, Carlsbad, CA 92009-1541 Description Manufactured from cast brass, our angle valves are for Trim or Drain applications and are designed to be suitable for all sprinkler systems including high pressure systems. The soft seat design utilizes NBR Nancar N70 material for posi- tive sealing to 300 psi. The most common use for the 2" IPS size is as a system drain at the riser. May be used on both alarm valve and shotgun type riser,assemblies: *UL/ULC Listed, 2R97 ©1996-2002 Fire Protection Installation Installation of the Trim/Drain valves can be accomplished using normal installation methods. Use a suitable thread sealant such as PipeFit Thread Sealant with PTFE* or PTFE*Tape to assure a positive seal be- tween the valves and the installed pipe. Caution: Do not over - tighten male threads into the valve body. Thread damage or craking of the valve body may occur. *PTFE is the chemical equivalent of Teflon® Teflon is a registered trade- mark of DuPont. Inc. Specs Materials Cast Brass: Body Bonnet Brass ASTM 1316: Gland Holder Stem Washer Stainless Steel: Nut NBR Nancar N70 Rubber seat JIS FC20: Hand wheel Sizes: 1/2" IPS FxF 3/4" IPS FxF 1" IPS FxF 1 1/4" IPS FxF 1 1/2" IPS FxF 2" IPS FxF For questions: 1 800 344-1822 1 800 344-3775 fax http://www.fppi.com Tri m F it® Bronze Globe Valve with Teflon* Seat, U L/U LC Listed 300 psi Description FPPI TrimFit® Bronze Globe Valves are precision cast then machined using state of the art facilities. Each valve features a full floating seat holder for reduced seat wear when clos- ing the valve. Seat is made of pure virgin Teflon* for longer seat life and reduced mainte- nance as compared to rubber seat valves. TrimFit trim valves are suitable for use in regular (175psi) and high pressure (300psi) sprinkler systems. Standard configuration is FNPT x FNPT and is available in 1/4" IPS through 2" IPS sizes. Each valve carrries the UL Listing and is rated for use to 300psi. UL/ULC Listed 21197 Installation Install in accordance with usual and customary installation techniques for fire sprinkler systems. Use a suitable thread sealant on the male threads of the pipe being threaded into the valve body. We recommend either TeflonW tape or PipeFitO Thread Sealant Paste with PTFE. (PTFE is the chemical equivalent of Teflon*) DO NOT OV ERTIGHTEN. OVERTIGHTEN- ING MAY CAUSE CRACKS OR LEAKS. "Teflon® is a registered trade- mark of DuPont. PipeFit®, TrimFite are regis- tered trademarks of Fire Protec- tion Products, Inc. F P P .1 ra remocnox rmmcs ec ©2000-2002 Fire Protection Products, Inc. Specs Material: Brass or bronze Seat -Teflon* Hand wheel-JIS FC 20 painted red. Sizes: 06-798114" IPS FNPT D6-800112" 06-802 3/4" 06-8041" 06-8061114" 06.80811/2" 06-810 2" For questions: 1 800 344-1822 1 800 344-3775 fax hftp:/Awiw.fppi.com info@fppi.com Three-way Bronze Valve, 1/4" IPS U L/U LC Listed* 300 psi Description The 1/4" IPS three-way female threaded valve is used to facilitate the installa- tion of sprinkler system pressure gauges. The valve g1997-2002 FirEpF9"g f��cffiRjnjpA and two outlets. This design allows for replacement of the system gauge without shut- ting down the water supply to the sprinkler system. This design also allows Authoritys' Having Jurisdication to test system pressure with an additional _ gauge through the second ' outlet. (The second outlet is normally plugged during installation with a 1/4" IPS pipe plug.) UUULC Listed 2R97 Installation Installation of the three-way valve can be accomplished with normal field installation tools. Make sure the valve is installed according to the flow indication arrow that has been cast into the valve body. The most common installation allows for a•1/4" IPS nipple between the valve and the water supply being mea- sured. This assures there will be adequate spacing for the sprinkler system gauge. Use either Teflon® tape or a suitable pipe thread sealant such as Pipefit Thread Sealant Paste with PTFE when installing the valve. DO NOT OVER TIGHTEN THREADS. OVERTIGHT- ENING MAY CAUSE VALVE FAILURE. Specs Size: 1/4" IPS Material: Body - Bronze Seat - Brass Handwheel - Iron Finish: Rough brass Working Pressure: 400 WOG For questions: 1 800 344-1822 1 800 344-3775 fax http://www.fppi.com info@fppi.com 6. DEVICES & IUSC. MUELLER° SUPER CENTURION° 9A FIRE HYDRANT Rev. 12-01 MUELLER SUPER CENTURION 25V 3-Way Fire Hydrant Features ❑ ANTI -FRICTION WASHER helps assure easy taming operation for the life of the hydrant. ❑ OIL FILLER PLUG permits quick check of oil level. Lets you add oil without removing bonnet. ❑ OIL RESERVOIR O-RING SEALS seal oil in, water out. ❑ HOLD-DOWN NUT - with integral weather seal. Design discourages unauthorized removal of the hold-down nut or bronze operating nut. Resilient wiper seal between hold-down nut and operating nut prevents water entry to protect operating nut from freezing. Wiper seal material is resistant to ultra -violet my deterioration. 0-ring seal provides second level of protection. ❑ STAINLES STEEL SAFETY STEM COUPLING - pulls free if hydrant is hit by a vehicle preventing damage to the stem and main valve. Coupling will not break into pieces that could drop into lower barrel and affect valve operation. Top of lower stem is below the top of the lower barrel so that a tire cannot depress the stem and open the main valve. Repair is easy and economical. ❑ SAFETY FLANGE - breaks cleanly to help prevent barrel damage, yet is strong enough to withstand normal handling. Allows economical repair, adding of extension section, rotation or changing of upper barrel without digging or water shut-off. ❑ BRONZE UPPER VALVE PLATE conical design for smooth flow. ❑ DRAIN VALVE FACINGS specially designed, long -life facings provide effective sealing. ❑ DUCTILE IRON CAP NUT retains main valve. Seats against cap nut gasket to prevent corrosion of stem threads. Locked in place by a stainless steel lock washer. Mueller HP Epoxy coated for durability. ❑ 250 PSIG - 3-way hydrant: 250 psig (1723 kPa) maximum working pressure, 500 psig (3447 kPa) ❑ SHOE DESIGNED FOR MAXIMUM FLOW AND EASY CONNECTION with its smooth transitional contours, extended neck and integral anti -rotation pads, allowing use of standard tee -head bolts. The inside of the shoe is covered with MUELLER HP® Epoxy Coating. This thermosetting epoxy fors a tough corrosion -resistant barrier to chemicals, physical impact and electrical currents. ❑ MEETS OR EXCEEDS all applicable requirements of ANSUAW WA C502 Standard and UL 246 and FM 1510 specifications. ❑ O-RING SEALS AT BONNET, GROUND, AND SHOE FLANGES for better leak resistance, easier maintenance. ❑ SEALED OIL RESERVOIR - 0-ring sealed to prevent leakage. Provides positive lubrication of stem threads and bearing surfaces each time the hydrant is operated. Filled at the factory. ❑ FULL FLOW OPENINGS large radius hose and pumper openings produce low friction loss. Cl FIELD REPLACEABLE HOSE AND PUMPER NOZZLES - 0-ring sealed. Threaded in place and retained by stainless steel locks. Nozzles are easily replaced. ❑ ELECTRO-GALVANIZED BOLTS AND NUTS - provide corrosion protection. ❑ NON -KINKING CHAINS heavy-duty chains are securely attached to the hydrant. Special chain loop.permits free turning of the cap. ❑ BRONZE SEAT RING - threaded into drain ring and 0-ring sealed. Seat ring is easily removed or installed from above ground. Each time main valve is opened or closed, double drain valves force -flush both drain valve openings to keep them open for effective barrel drainage. Bronze drain valves are integral parts of main valve assembly. ❑ REVERSIBLE, COMPRESSION TYPE MAIN VALVE - closes with pressure for positive seal. Rubber material has long service life, yet is reversible providing a convenient spare in place. Manufactured under one or more of the following: U.S. Patent No. 4,717,178; 4,842,246. 9.2 Rev. 12-01 MUELLER SUPER CENTURION 20V 2-Way and 1-Way Fire Hydrant i ❑ Meets all applicable parts of ANSUAW WA C502 Standard ❑ Hold-down nut with integral f weather seal; designed to discourage unauthorized -tampering ❑ Gasket seals at bonnet, ground and shoe flanges ❑ Dry top design with 0-ring sealed 'oil reservoir ❑ Stainless steel safety stem coupling pulls free if hydrant is hit by a vehicle preventing damage to the stem and main valve ❑ Reversible, compression -type main valve closes with pressure for positive seal ❑ Low flow loss design with full flow nozzles and shoe ❑ Field replaceable nozzles ❑ Dual bronze drain ways ❑ 200 psig (1379 kPa) maximum working pressure, 400 psig (2758 kPa) test pressure MUELLER CENTURION Spin -In Fire Hydrant ❑ Lower barrel threaded to fit most sizes of R.D.Wood fire hydrant o shoes ❑ .Meets all applicable parts of ANSUAW WA C502 Standard ❑ Post type dry barrel design ❑ Dry top design with 0-ring sealed oil reservoir ❑ Traffic feature ❑ Reversible, compression -type main valve closes with pressure for positive seal ❑ Low flow loss design with full flow nozzles and shoe ❑ Field replaceable nozzles ❑ Dual bronze drain ways ❑ Two way and three way design ❑ 200 psig (1379 kPa) maximum working pressure, 400 psig (2758 kPa) test pressure MUELLER® FIRE HYDRANTS MUELLER MODERN CENTURION' Fire Hydrant ❑ Modem, sleek exterior design ❑ Meets all applicable parts of ANSUAW WA C502 Standard ❑ Post type dry barrel design ❑ Dry top design with 0-ring sealed �(p oil reservoir ❑ Traffic feature ❑ Stainless steel safety stem coupling pulls free if hydrant is hit by a vehicle preventing damage to the stem and main valve Cl Reversible, compression -type main valve closes with pressure for positive seal ❑ Low flow loss design with full flow nozzles and shoe ❑ Field replaceable nozzles ❑ Dual bronze drain ways ❑ Two way and three way designs ❑ 200 psig (1379 kPa) maximum working pressure, 400 psig (2758 kPa) test pressure MUELLER 2-1/8" Post and Flush Type Fire Hydrants �i ❑ 2-1/8" main valve opening ❑ Meets all applicable parts of f ANSUAW WA C502 Standard - ❑ Dry barrel design ❑ Used for blow offs, sampling, irrigation, golf course watering, . private estates, etc. ❑ Compression type main valve closes with pressure - ❑ Bronze drain ❑ Flush type has a cast iron box with lid ❑ 150 psig (1034 kPa) maximum working pressure 300 psig (2068 kPa) test pressure Manufactured under one or more of the following: U.S. Patent No. 4,717,178; 4,842,246. MUELLER° O.E.M. FIRE HYDRANT 903 REPAIR PARTS AND REPAIR KITS Rev. 499 MUELLER CO. considers a fire hydrant to be a critical piece of emergency equipment used to preserve lives and property. For this reason all Mueller Fire Hydrants are designed, built and tested to assure high performance and dependability. Each component part of a MUELLER Fire Hydrant is specially designed to assure proper and reliable operation. Attention to detail doesn't stop once the part is designed. Quality control tests are made on all component parts to assure dimensional and material integrity are maintained. Every MUELLER Fire Hydrant is pressure tested and operated before it leaves our plant to assure it meets our high quality standards. MUELLER CO. is confident it produces one of the most reliable fire hydrants available and backs this claim with a 10 YEAR LIMITED WARRANTY ON PARTS AND WORKMANSHW for the MUELLER Super CENTURION® Fire Hydrant. The claim of outstanding performance and reliability is proven by the fact that almost half of all the fire hydrants sold in the United States today are manufactured by MUELLER CO. A fire hydrant is exposed to the elements on a daily basis and over a period of time repairs may eventually become necessary. MUELLER CO. offers repair kits that have the same parts as are used in our regular production hydrants. When you use genuine MUELLER replacement parts you are assured the part matches the manufacturer's original equipment specifications with regard to dimensions, materials and performance. Only genuine MUELLER parts are marked with the MUELLER name. EO e Typical shoe repair kit Typical bonnet repair kit Typical safety flange repair kit Typical main valve repair kit 9A Rev. 12-01 MUELLER" SUPER CENTURION° ` ❑ Super Centurion 25r3-way catalog numbers (approved to III. 262, FM 1120/1130, ANSDAW WA C502 Standards) - A=421-4-1/2" main valve opening three way (two hose nozzles andonepumper nozzle) A423 5-1/4" main valve opening three way (two hosenozzlesand one pumper nozzle) Super Centurion 200"'2-way catalog numbers (approved to ANSUAW WA C502 Standards) - A-420 4-1/2" main valve opening two way (two hose nozzles) A-422 5-1/4" main valve opening two way (two hose nozzles) A425 5-1/4" main valve opening two way (two pumper nozzles) Super Centurion•200'"1-way catalog number (approved to ANSI/AWWA C502 Standards)- A424 4-1/2" main valve opening one way (one pumper nozzle) ❑ 10 year limited warranty on materialand workmanship ❑ Meets all applicable parts of ANSI(AW WA C502 Standard ❑ Post type dry barrel design ❑ Dry top design with 0-ring sealed oil reservoir ❑ Traffic feature with stainless steel safety stem coupling ❑ Compression -type main valve closes with pressure for positive seal; it is made of rubber and is conveniently reversible providing a spare for long service life ❑ Operating nut available in wide variety of shapes and sizes -open left or right ❑ Field replaceable hose and pumper nozzles ❑ Hose and pumper nozzles have large radius, full flow openings for low friction loss ❑ Contoured, shoe is designed for full flow ❑ Dual bronze drain valves provide effective barrel drainage ❑ 250 psig.(1723 kPa) maximum working pressure, 500 psig (3447 kPa) static test pressure for 3-way hydrants; 200 psig (1379 kPa) maximum working pressure, 400 psig (2758 kPa) static test pressure for 2-way and 1-way hydrants Dimensions Mechanical join) standard and D- .y__ o< Flange ANSI ror Ov::a-.. �\ PN 10/16 Drilling FIRE HYDRANT Non -rotating bolt design: cast -in pads eliminate need for anti -rotation bolt Front view detail o Mechanical joint (Standard only) Vertical Flange ' 4" Vertical shoe available for A-420 and A-421 hydrants. SEE PAGE 9.24 FOR ORDERING INSTRUCTIONS INDICATOR POST STYLE 2945 A TELESCOPING BARREL ASSEMBLY UL AND FM APPROVED KENNEDY VALVE Available in Sizes B C D E See Page 6 for Dimensions P-2 P-1 P-3 P-4 ° P-5 P-6 P-7 P-8 p 5 u i � P-9 P-10 P-12 IP-11A P-15 / P-i 6 P-13 � P-14 / P-17 P-18 P-19 P-20 P-21 1 Page 1 — 2945 1 '/4" Sq. max. = Y 0" min. = 7" :)p of the ms and )f 9" above :s for the rof the Page 2 — 2945 INDICATOR POST STYLE 2945 FIXED LENGTH ASSEMBLY UL AND FM APPROVED KENNEDY VALVE Available in Sizes F G H See Page 6 for Dimensions P-2 P-1 P-3 P-4 ° P-5 P-6 1 P-7 -I I I I i P-8 0 p S � i P-g 10 P-10 -- t P-23 01 P-11F P-12 P-13 P-22 P-14 P-18 P-19 P-20 P-21 i Page 3 — 2945 6" Dia. 36 3/a" Trench Depth 12" Dia. INDICATOR POST STYLE 2945 FIXED LENGTH UL/FM DIMENSIONS AND INSTRUCTIONS 1'/4" Sq. Top Section Standpipe (painted red) Ground Line Standpipe / (painted black) KENNEDY VALVE Available in Sizes F G H See Page 6 for Dimensions 1" Sq. Stem I I max. = 10" 9 min. = 7" —I.— r— FIELD ADJUSTMENT INSTRUCTIONS 1. Remove the top section from the top of the Indicator Post assembly. 2. Cut the required length off the bottom of the Standpipe for the Ground Line to match up with Standpipe Ground Line mark. ' 3. Cut the 1 " Sq. Stem at a distance of 9" above . the top of the Standpipe. 4. Set the "OPEN" and "SHUT'targets for the appropriate valve size. 5. Reattach the Top Section to the top of the Indicator Post assembly. Page 4 — 2945 JCM 432 All Stainless Steel Tapping Sleeve JCM 462 Stainless Steel Tapping Sleeve with Carbon Steel Flange EXTRA BOLTING POWER ... The true tapping sleeve design of this sleeve incorporates replaceable, self -aligning bolts, which facilitate conversion of high bolt torques to high -gasket pressure, can be torqued to 125 ft. lbs. This increases gasket sealing pressure and pressure holding capability. FULL CIRCUMFERENTIAL SEAL. -The extra bolting power assures the gasket will seal the full circumference of the pipe. This provides insurance against beam breaks in size on size taps. Molded in recessed bridge plate assures even gasket pressure throughout the range of the sleeve. I Patent #4,708,373 STRONGER YET LIGHTER THAN CAST SLEEVES... Extra strength eliminates possible cracking of the sleeve or flange. Reduced weight speeds installation and reduces the load placed on the pipe. EXTRA WIDE FOR SUPPORT AND STABILITY... Extra width and heavier neck and body material provide extra reinforcement of the outlet and extra stability during the tapping process. JCM 432 - All stainless construction provides extra corrosion resistance. The stainless steel flange, outlet and body join as one unit of similar metals for highest structural strength and corrosion resistance. JCM 462 - Stainless steel body/neck construction joins with a strong, economical carbon steel flange. Coated steel flange is to AWWA C207, Class D standard with recess for tapping alignment. MATERIAL SPECIFICATIONS - JCM 432 and 462 TAPPING SLEEVES: BODY: BOLTS: BRANCH OUTLET - GASKET. 432 FLANGE: 462 FLANGE: Stainless Steel, 18-8 Type 304 Stainless Steel, Type 304 Heavy Stainless Steel Pipe Full circumferential gasket compounded for use water, salt solutions, bases and sewage. CF8 Cast Stainless Steel - equivalent to 18-8 Type 304 Stainless Drilling, recessed for tapping valve per MSS-SP 60. NSF. mild acids, Steel. ANSI 1501b. AWWA C207 Class D, ANSI 1501b. Drilling, recessed for tapping valve MSS-SP60. JCM Tapping Sleeves meet or exceed the ANSI/AWWA C-223 and the MSSSP 124 Standards as applicable. JCM 432 & 462 STAINLESS STEEL TAPPING SLEEVE DIMENSIONS 4FLAN'�"v.. E,S'S .A _ a .B C.. D...$ E. F..,,. 2 15 5 3-1/32 2.16 10 5/8 3 15 5 4-1132 3.26 10 5/8 4 15 5 5-1132 4.26 10 5/8 6 15 5 7-1132 6.35 10 5/8 8 - 21 5-1/8 9-1/32 8.32 14 5/8 10 27 5-112 11-1/16 10.42 18 5/8 12 30 5-3/4 13-1/16 12.39 20 5/8 70 Stainless Steel Tapping Sleeve - Full Circumferential Gasket - Flanged Outlet JCM 432 Stainless Steel Flanged Outlet JCM 462 Carbon Steel Flanged Outlet NOM. SLEEVE MODELA32 MODEL 462 ' WIDTH NUMBER ' gppR.,, PIPE STAINLESS STEEL GARBONSTEEL OUTLET O:D.RANGE OF OF wT.EA. SIZE FLANGE FLANGE: SIZES (IN:) 'SLEEVE BOLTS LEIS (IN;) SLEEVE'NUMBER- SLEEVE NUMBER 4.40 - 4.60 432-0450 462-0450 - X 2 15 10 38 4 4.60 - 4.80 432-0465 462-0465 X 3 15 10 40 4.74 - 5.00 432-0480 462-0480 X 4 15 10 42 5.10 - 5.30 432-0520 462-0520 6.56 - 6.90++ 432-0663 462-0663 X 2 15 10 42 6.83 - 7.16 432-0690 462-0690 X 3 15 10 42 6 7.05 - 7.40 432-0720 462-0720 X 4 15 10 47 7.40 - 7.73 432-0745 462-0745 X 6 15 10 49 X 2 15 10 45 8.54 - 8.74 432-0663 462-0663 X3 15 10 45 6 8.60 - 9.05" 432-0900 462-0900 X 4 15 10 51 8.98 - 9.37 432-0905 462-0905 X 6 15 10 54 9.27 - 9.69 432-0940 462-0940 X 8 21 14 78 X 2 15 10 46 9.83-10.25+ 432-1000 462-1000 X 3 15 10 46 10.64 - 10.86 432-1075 462-1075 ' X 4 15 10 55 10 11.00 -11.40 432-1110 462-1110 X 6 15 10 60 11.36 -11.80 432-1140 462-1140 X 8 21 14 72 11.76 -12.24 432-1200 462-1200 X to** 27 1 18 132 X 2 15 10 47 12.62 -12.88 432-1275 462-1275 X 3 15 10 47 12.75-13.20++ 432-1300• 462-1300• X 4 15 10 60 12 13.10 -13.50 432-1320 462-1320 X 6 15 10 64 13.70 -14.09 432-1392 462-1392 X 8 21 14 90 14.08 -14.40 432-1420 462-1420 X 10" 27 18 138 X 12'• 30 20 161 X2 15 10 74 X 3 15 10 74 15.20 -15.60 432-1530 462-1530 X 4, 15 10 80 14 16.80 - 16.20 432-1600 462-1600 X 6 15 10 85 16.38 - 16.78 432-1650 462-1650 X 8 21 14 114 X 10•' 27 18 150 X 12'• 30 1 20 171 X2 15 10 78 X 3 15 10 78 17.40 -17.80 432-1740 462-1740 X 4 15 10 78 16 17.75 -18.15 432-1800 462-1800 X 6 15 10 90 18.58 - 18.98 432-1875 462-1875 X 8 21 14 126 X 10'• 27 18 163 X 12" 30 20 175 X 3 15 10 80 19.30 -19.70 432-1950 462-1950 X 4 15 10 80 18 19.80 - 20.20 432-1990 462-1990 X 8 15 10 90 21.20 - 21.40 432-2130 432-2130 X 8 1 21 14 1 130 X 3 15 10 85 21.40 - 21.80 432-2160 462-2160 X 4 15 10 85 20 21.90 - 22.30 432-2206 462-2206 X 8 15 10 22.30 -22.70 432-2250 432-2250 X 8 21 14 136 X3 15 10 105 23A5-23.85 432-2360 462-2360 X4 15 10 105 24 26.60-26.00 432-2580 462-2580 X 6 15 10 125 26.20 - 26.60 432-2632 462-2632 X 8 21 14 150 +NOTE: THIS SIZE NOTAVAILABLE WITH A SIZE ON SIZE OUTLET. ++NOTE: RECOMMENDED FOR IPS PVC, STEEL, C-900 PVC, DUCTILE IRON PIPE DIAMETERS. NOT RECOMMENDED FOR PIT CAST IRON PIPE. FOR OVERSIZED OR PIT CAST IRON PIPE, SEE NEXT LARGER RANGE *NOTE: NOT AVAILABLE IN 10' OR 12' OUTLET SIZES _ "NOTE: MAXIMUM WORKING PRESSURE 150 PSI, MAXIMUM TEST PRESSURE 200 PSI. For larger sizes and outlets, see JCM 412 Tapping Sleeve or JCM 452 All Stainless Steel Tapping Sleeve. HOW TO ORDER-JCM TAPPING SLEEVES NSE 1. Determine O.D. of pipe. n r 2. Select proper sleeve O.D. range. 3. Specify catalog number and outlet size. c,xn^,e xaxuss Example: For PVC pipe with 8.63 O.D. with 6' outlet, order. 432-0663 x 6. For carbon steel Flange, order 462-0863 x 6. 71 Tyler/Union New ways to save on valve boxes. Eliminate extra handling by buying pre -assembled units. Save on single parts and accessories. Lower unit cost by purchasing Valu-Pales of 30 to 80 pieces of tops and bottoms in crates. See list price sheet for pricing details. THREE WAYS TO SAVE 6850 VALVE BOX Level) Level Level Boxes Individual Parts VAW-PAK Parts Assembled Not Assembled Not Assembled Note: A "BOX" is one top and one bottom Box Assembled , LEVEL ONE: BOXES ASSEMBLED LESS LIDS 6850 SERIES CAST IRON TWO-PIECE VALVE BOXES for 4" through 12" valves, 51/4" shaft, screw -type 5dension UPC No. Box (Components) Height 670610 Weight A61-5 (IOT+ 15B) 19-22 (Not Offered Assembled 462-5 (IOT+24B) 27-32 (Not Offered Assembled 562-5(16T+24B) 27-37 145790 71 563-5 (I 6T + 30B) 33-43 145752 78 564-5 (I 6T + 36B) 39.50 1 A5806 85 662-5(26T+30B) 36-52 145769 93 664-5 (26T+36B) 39-60 145813 100 666-5 (26T+ 24B + #60 Ext) 51-71 (Not Offered Assembled) 668-5 (26T + 36B + #60 Ext) 62-82 (Not Offered Assembled) Level Two Top Level Two Bottom --�I Tyler Pipe/Utilities Division • P.O. Box 2027 • Tyler, Texas 75710 • (903) 882-5511 36 Union Foundry Company • P.O. Box 309 • Anniston, Alabama 36202 • (256) 236-7601 4-4-2003 Tyler/Union 685c SERIES CAST IRON TWO-PIECE VALVE BOXES for 4" through 12" valves, 51/a" shaft, screw -type LEVEL TWO - Parts Not Assembled/Less Lids IZ7�"i��•] i t•]�SF: _ Box (Components) Assy Height Tops Pass lids) _ _UPC. No. 670610 Lgt - Wt Bottoms -UPC No.- 670610 Lgt Wt Extensions _UPC. No. 670610 461 -S (I OT + 15B) 19.22 144939 10T 22 145004 15B 27 462-S (10T+24B) 27-32 144939 10T 22 145011 24B 35 562-S(16T+24B) 27-37 144946 16T 36 145011 24B 35 563-S (16T + 30B) 33.43 144946 16T 36 144991 30B 42 564-S (16T - 36B) 39-50 144946 16T 36 145028 36B 49 662-S (26T - 30B) 36-52 144953 26T 51 144991 30B 42 664-S (26T + 36B) 39-60 144953 26T 51 145028 36B 49 666-S 126T + 24B + #60 Ext) 51-71 144953 26T 51 *145011 24B 35 145059 668-S (26T + 36B + #60 Ext) 62-82 144953 26T 51 *145028 36B 49 145059 . 6850 Bottoms EXTENSIONS UPC No. Height Item/Description 670610 Increase Wt #58 Screw -Type 145141 14 29 #59 Screw -Type 145158 18 30 #60 Screw Type 145059 24 37 I~-53/4 1 r- 5''1a a N 0 o Co 6 P 2�` 7 8 ii8 58 and 59 Extension 60 Extension LEVEL THREE - Crates of tops and bottoms, not assembled, less lids. Easy to handle, ships from stock. TOPS OR BOTTOMS Tops (less lids) Bottoms Assy UPC No.' UPC No. Box (Components) Height 670610 Lgt Wt Qty 670610 Lgt Wt Qly 461-S (1 OT+ 15 B) 19-22 376910 10T 1760 80 376941 15B 1080 40 462-S (1OT+24B) 27-32 376910 10T 1760 80 376958 24B 1050 30 562-5(16T + 2413) 27-37 376927 16T 2160 60 376958 24B 1050 30 563-S (16T + 30B) 33-43 376927 16T 2160 60 376965 30B 1260 30 564-S(16T+36B) 39-50 376927 16T 2160 60 376972 36B 1470 30 662-S (26T + 30B) 36-52 376934 26T 1530 30 376965 30B 1260 30 664-S(26T + 363) 39-60 376934 26T 1530 30 376972 36B 1470 30 666-S (26T + 24B + #60 Ext) *51-71 376934 26T 1530 30 •376958 24B 1050 30 668-5 (26T + 36B + #60 E)d) *62-82 376934 26T 1530 30 1 '376972 36B 1470 30 `Extensions (Required on 666-S & 668-S) *6850 Bottoms #60 Screw -Type 24" Height Increase 376989 1080 30 NOTES: To get equal numbers, order two crates of bottoms for each crate of tops for A61 S, 562S, 563S and 564S. Order lids separately, see above. Tyler Pipe/Ufilifies Division • P.O. Box 2027 • Tyler, Texas 75710 • (9031882-5511 4-4.2003 Union Foundry Company • P.O. Box 309 • Anniston, Alabama 36202 • (256) 236-7601 37 (B.POTTE OSYSU-1 Stock No. 1010106 OSYSU-2 Stock No. 1010206 GENERAL INFORMATION The OSYSU is used to monitor the open position of an OS & Y (outside screw and yoke) type gate valve. This device is available in two models; the OSYSU-1, containing one set of SPDT (Form C) contacts and the OSYSU-2, containing two sets of SPDT (Form C) contacts. These switches mount conveniently to most OS & Y valves ranging in size from 2" to 12". They will mount on some valves as small as 1/2". The cover is held in place by two tamper resistant screws that require a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replacement or additional OSYSU-15 -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH UL and CSFM Listed, FM Approved, NYMEA Accepted, CE Marked Dimensions: 6.19"L X 2.25'W X 5.88"H 15.7cm L X 5.7cm W X 14.6cm H Weight: 2 lbs. (.9 kg.) Enclosure: Cover - Die -Cast Finish- Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. Cover Tamper: Tamper resistant screws, Optional cover tamper kit available. Contact Ratings: OSYSU-1: One set of SPDT (Form C) OSYSU-2: Two sets of SPDT (Form C) 15.00 Amps at 125/250VAC 2.60 Amps at 30VDC resistive Environmental Limitations: • NEMA 4 and NEMA 6P Enclosure (IP67) when used with appropriate watertight conduit fittings. • Indoor or Outdoor use (Not for use in hazardous locations. See bulletin no. 5400705 OSYS-U-EX for hazardous locations.) • Temperature Range: -40°F to 140°F (-40°C to 60°C) Conduit Entrances: 2 knockouts for 1/2" conduit provided Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 cover screws and hex keys are available. See ordering information on page 4. OPTIONAL COVER TAMPER SWITCH A field installable cover tamper switch is available as an option which may be used to indicate removal of the cover. See ordering information on page 4. TESTING The OSYSU and its associated protective monitoring system should be inspected and tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). PotlerElectdcSignal Company • 2081 Craig Road, St. Louis, MO, 63146-4161-Phone: 800-325-3.936/Canada888-882-1833-www.pottersignal.com PRINTED IN USA MKT. #8820004 - REV N PAGE 1 OF 4 9199 FIG. 1 Po'ul* OSYS-2 AND OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH SMALL VALVE INSTALLATION -1/2" THRU 2112" SIZES THESE SWITCHES MOUNT CONVENIENTLY TO MOST 2" TO 12" OS & Y VALVES. THEY WILL MOUNT ON SOME VALVES AS SMALL AS 1/2". J-HOOKS MAY BE REQUIRED ON VALVES WITH LIMITED CLEARANCE. CLAMP BAR W:LaNUM[01111*4 SMALL VALVE INSTALLATION 1. Remove and discard "C" washer and roller from the trip rod. 2. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non - threaded portion of the valve stem. 3. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 procedure. 4. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. On valves with limited clearance use J-hooks supplied instead of the carriage bolts and clamp bar to mount the OSYSU. 5. Mark the valve stem at the center of the trip rod. SLOTTED MOUNTING HOLES MAY BE USED FOR FINE ADJUSTMENT OF SWITCH ON BRACKET BRACKET DWG. #979-3 6. Remove the OSYSU. File a 1/8" deep groove centered on the mark on the valve stem utilizing a 3116" round, non - tapered file. Round and smooth the edges of the groove to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. 7. Mount the OSYSU with the trip rod centered in groove. 8. Final adjustment is made by loosening 2 screws (see Fig. 1) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate when the trip rod moves out of the groove. 9. Tightenthe adjustmentscrews and all mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. #8820004 - REV N PAGE 2 OF 4 9/99 ( PC3TT OSYSAND -2 OUTSIDE SCREW AND YOKE VALVE SUPERVISORY SWITCH FIG. 2 LARGE VALVE INSTALLATION - 3" THRU 12" SIZES 3" THRU 12" VALVES USE CARRIAGE BRACKET BOLTS. CARRIAGE BOLTS MOUNT ON INSIDE OF YOKE, IF THERE CLAMP BAR IS SUFFICIENT CLEARANCE. SLOTTED MOUNTING HOLES. MAY BE USED FOR FINE ADJUSTMENT OF SWITCH ON BRACKET. /)] DWG. #979-4 LARGE VALVE INSTALLATION 1. With the valve in the FULL OPEN position, locate the OSYSU across the valve yoke as far as possible from the valve gland, so that the trip rod lays against the non - threaded portion of the valve stem. 2. Mount the OSYSU loosely with the carriage bolts and clamp bar supplied. 3. Loosen the locking screw that holds the trip rod in place and adjust the rod length (see Fig. 4). When adjusted properly, the rod should extend past the valve screw, but not so far that it contacts the clamp bar. Tighten the locking screw to hold the trip rod in place. NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig. 5). Reinstall trip rod and repeat Step 3 procedure. 4. Mark the valve stem at the center of the trip rod. 5. Remove the OSYSU. File a 1/8" deep groove centered on the mark of the valve stem utilizing a 3/8" round, non - tapered file. Round and smooth the edges of the groove ROLLER GROOVE �YOKE VALVE STEM TRIP ROD GLAND to prevent damage to the valve packing and to allow the trip rod to move easily in and out of the groove as the valve is operated. 6. Mount the OSYSU loosely with the trip rod centered in groove. 7. Final adjustmentismade byloosening 2screws (see Fig. 2) and sliding the OSYSU on the bracket. Adjustment is correct when switches are not activated with the trip rod seated in the valve stem groove and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. 8. Tighten the adjustmentscrews and mounting hardware. Check to insure that the rod moves out of the groove easily and that the switches activate within one turn when the valve is operated from the FULL OPEN towards the CLOSED position. NOTE: CLOSE THE VALVE FULLY TO DETERMINE THAT THE STEM THREADS DO NOT ACTIVATE THE SWITCH. THE SWITCH BEING ACTIVATED BY THE STEM THREADS COULD RESULT IN A FALSE VALVE OPEN INDICATION. PRINTED IN USA MKT. 98820OD4 - REV N PAGE 3 OF 4 9199 OUTSIDE SCREW AND YOKE VALVE ,POTTEJSUPERVISORY SWITCH FIG.3 DIMENSIONS BREAKING EXCESSIVE ROD LENGTH FIG. 5 SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL 1-1 1440 es po—a CAUTION: An uninsulated section of a single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, thereby providing supervi- sion ofthe connection in the evenithatthewire becomes dislodged from underthetenninal. ORDERING INFORMATION MODEL DESCRIPTION STOCK NO. OSYSU•1 Outside Screw&Yoke•Supervisory Switch (Single switch) 1010106 — OSYSU-2 Outside Screw & Yoke -Supervisory Switch (Double switch) 1010206 _ -- Cover Screw 5490344 - Hex Key for Cover Screws and Installation Adjustments 5250062 Optional COverTamperSwItch Kit 0090131 For pressure reducer type valve installation kits (if required) contact valve manufacturer FIG.4 PARTS TYPICAL ELECTRICAL CONNECTIONS ttrx aamrt TO I'MER FOR mama amal TO stpommy aFDLTT I10. N� Hamm PME as am OF ua ME= ore. Jam-1 Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION OPEN VALVE POSITION COM. N.O. SW j1 I COM. I + N.O. SW Z N.C. CLOSED VALVE POSITION COMA N.O. SW #1 N.C. I I CON. j N.O. SW #2 N.C. DWG- #979-2 PRINTED IN USA MKT. #8820004 - REV N PAGE 4 OF 4 9/99 CONTROLVALVE (2),POTTE SUPERVISORY SWITCH PCVS-1 Stock No. 1010107 PCVS-2 Stock No. 1010207 The Model PCVS is a weather proof and tamper resistant switch for monitoring the open position of fire sprinkler control valves of the post indicator, butterfly and other types. Depending on the model, one or two SPOT (Form C) contacts are provided which will operate when the valve position is altered from an open state. The unit mounts in a 1/2" NPT tapped hole in the post indicator or butterfly valve housing. The device is engaged by the indicating assembly of the post indicator or the operating mechanism of the butterfly valve, actuating switch(es) when the valve is fully open. The unit should be installed where it is accessible for service. The cover is held in place by two tamper resistant screws that require UL and CSFM Listed, FM Approved, NYMEA Accepted, CE Marked Dimensions: 4.75"L x 2.25"W x 7.2"H (stem extended) 12.1cm L x 5.7cm W x 18.3cm H Weight: 1.35 lb. (.61 kg.) Enclosure: Cover - Die-cast Finish - Red Spatter Enamel Base - Die Cast Zinc All parts have corrosion resistant finishes. CoverTamper: Tamper Resistant Screws, Optional cover tamper kit available Mounting: 1/7" NPT Contact Rating: PCVS-1: One set of SPDT (Forth C) PCVS-2: Two sets of SPOT (Form C) 15.00 Amps at 125/250VAC 2.50 Amps at 30VDC resistive Environmental Limitations: -40°F to +140°F (40`C to 60°C) NEMA 4 and NEMA 6P Enclosure (IP67) when used with appropriate watertight conduit fittings. Indoor or Outdoor Use (Not for use in hazardous locations. See bulletin no. 5400694 PIVS-U-EX for hazardous locations.) Conduit Entrances: Two knockouts for 1/2" conduit provided. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 a special tool to remove. The tool is furnished with each device and should be left with the building owner or responsible party. Replace- ment or additional cover screws and hex keys are available. See ordering information. OPTIONAL COVER TAMPER SWITCH: A field installable cover tamper switch is available as an option which maybe used to indicate removal of the cover. See ordering information. TESTING: The PCVS and its associated protective monitoring system should be tested in accordance with applicable NFPA codes and standards and/or the authority having jurisdiction (manufacturer recommends quarterly or more frequently). ORDERING INFORMATION - MODEL DESCRIPTION STOCK NO. PCVS-1 Potter Control Valve Switch (single switch) 1010107 PCVS-2 Potter Control Valve Switch (double switch) 1010207 -- Cover Screw 5490344 -- Hex Key for Cover Screws and Installation Adjustments 5250062 f PBK-S Pratt Butterfly Valve Kit (Up to 12') 0090133 . PBK-L Pratt Butterfly Valve Kit (14" and Up) 0090132 PVK Pratt Valve Kit 1000060 _, -- Optional Cover Tamper Switch Kit 0090131 For pressure reducer type valve installation kits (if required) contact valve manufacturer PotterElectricSignal Company • 2081 Craig Road, St Louis, MO, 63146-4161 • Phone:800325-3936/Canada888-882-1833•www.poltersignal.com PRINTED IN USA MKT. #8820001 - REV 0 PAGE 1 OF 4 9199 O FIG.1 DIMENSIONS 1. f99o-1 PCVS-1, -2 CONTROLVALVE SUPERVISORY SWITCH FIG.2 PARTS GROUND SCREW TRIP ROD LOCION^u SCREW SOCKET HEAD SCREW NIPPLE LDCKNUT TRIP ROD TYPICAL INSTALLATIONS ON POST INDICATOR VALVE HOUSINGS (SEE FIGS. 3 THRU 6) Referto Fig.2forlhelocation of parts descri bed in thefollowinginstwctions. open end of the nipple to the target assembly. Subtract 1/2" from this NOTE: If the sprinkler system is in service the owner or authorized measurement. representative should benotifed, before anyworkisdoneonthe system, that NOTE: In some cases, it may be necessary to attach an angle bracket the valve controlling the water supply to the system may be closed for periods to the target assembly to engage the PCVS trip rod. of time during the installation and testing of this device, resulting in all or 10. Using the special tool provided, loosen the two coverscrews and remove portions of the system being inoperative during these periods. the cover from the PCVS. If the system is not in service and valve is closed, be sure that opening the 11. Loosen the locking screw that holds the trip rod in place and adjustthe valvewill nolallowany unwanted waterflowdueto openingsin the system, rod length, from the end of the collar to the end of the rod, using the such as heads off, broken or incomplete piping, etc. dimension determined in Step 9. Tighten the locking screwto hold the rod 1. Position the valve to fully open(°OPEN°should appearin the windowof in place. the housing). Partially close the valvewhile observing thedirection that the target assembly moves. Reopen the valve. If the valve housing is predrilled with a 1/2" NPT for installation of a monitoring switch, removelhe 1/2" plug and fullyopen the valve. Make sure that"OPEN° appears in thewindowofthe housing. GO TO STEP NO. 6. 2. Removethe head andlargetassembly(consultationwithvalve manufac- turer is recommended). 3. If the target assembly moved up as the valve was closed, measure the distance from the bottom of the head to the lower part of the target assembly that will contact the trip rod of the PCVS (see Fig. 3). This is usually a plate or bar on the target assembly, on a side adjacent to the °OPENISHUT" plates. Subtract 1/8" from the measurement. If the target moved down as the valve was closed, measure the distance from the bottom of the head to the upper portion of the target assembly that will contact the trip rod of the PCVS (see Fig. 4). Add 1/8" to this measurement 4. Markthe housing atthe proper location. Using a 23/32" drill bit, drill and then tap a 1/2" NPT in the housing on the side that coincides with the portion of the target assembly thatwill engage the trip rod of the PCVS. 5. Replace the head and target assembly. 6. Loosen the socket head screw that holds the nipple in the PCVS and remove the nipple. 7. Screw the locknut that is provided onto the nipple. S. Screw the nipple into the 1/2" NPT hole in the valve housing - hand tighten. Tighten the locknut against the valve housing to secure the nipple firmlyin place. 9. Insert a scale or probe thru the nipple to measure the distance from the NOTE: If trip rod length is excessive, loosen the locking screw and remove the trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig.7). Reinstall trip rod and repeat Step 11 procedure. 12. Partially closethe valve (3 to4 revolutions ofthe handle/hand wheel). 13. Slide the PCVS unit as fares possible onto the nipple, observing which direction the rod will move when the valve is closed. Orient the device to actuate the switches when the valve Is open. Tighten the socket head screw in the collar. 14. Carefully open the valve to the fully open position. As the target moves to the open position it should engage the trip rod and actuate the switch(es). There should be a minimum overtravel of 1/2 revolution ofthe handle/hand wheel after the switch(es) actuate (a continuity meter connected to each set of contact's is one method that could be used to determinethis). 15. Slowly close the valve. The switch must operate during the first two revolutions ofthe handle/hand wheel orduring 115 ofthe travel distance of the valve control apparatus from its normal condition. NOTE: Small adjustments of the target position may be necessary (consultation with valve manufacturer is recommended). 16. Complete the required electrical wiring, connections and tests. The valve should beoperatedthrough the entire cycle offully closed andfullyopen to determine the integrity of the PCVS installation and the signaling system. Checklhatall electrical and mechanical connections are secure. 17. When the installation and testing are complete, return valveto its proper position. 18. Alternative installation forotherpostindicatorvalvehousing shown in Fig. 5 and 6. PRINTED IN USA MKT. #8820001 - REV Q PAGE 2 OF 4 9199 CONTROLVALVE (2),POTTE SUPERVISORY SWITCH FIG. 3 FIG. 4 FIG. 5 FIG, 6 MEM PlA1E REPLACES Cl lSS LOCKNUr TARGET EL MwEs 0 Rip UP AS ,ytppt TRIPPING VALVE UT, SNITCH �fiEPLACES 0 PEN. IS SHUT PEN 0 sync" TAMPER UT 0 OP 7ARGtS TAMPER MOVES G sNlrcn DOWN AS sxUr TARGET VALVE MARKEti A.�FMSLY FLEMOLE 11 3/8' 15 Sl1Ur CONOUrr TAAGEr HOOD MODES MOVES 13MI AS VALVE UP AS IsmHUT VALVE 1s SHUT DWG. #SSO-30 Notes: 1. Subject to the approval ofthe'authority having jurisdiction' the alternate method of installation shown in Fig. 5 maybe used. In this method, one of the glass windows of the housing is replaced with a 114" thick metal plate that is cut to fit in place of the glass and drilled and tapped to receive the 1/2" NPT pipe nipple. In some cases it may be necessary to attach an angle bracket to the target assembly to engage the PCVS trip rod. 2. If the target is stationary and a hood arrangement is used, such as is shown in Fig. 6, the hood must be drilled with a 23/32" drill and tapped with a 112" NPT. The center line of this hole should be 1/8" below the portion of target assembly that strikes the PCVS trip rod. The 11 3/8" dimension shown is for a Clow Valve. Flexible conduit must be used for this type of installation. TYPICAL INSTALLATION ON A BUTTERFLY VALVE (SEE FIGS. 9 AND 10) Refer to Fig.2 for location of parts described in the following instructions: St. Remove the 1/2" N PT plug from the gear operatorcase. B2 Loosen thesetscrewthat holdsthe nipple In the PCVS and removethenipple. E13: Screw the locknut that is provided onto the nipple. B4. Screw the nipple into the I/2"NPT hole in the gear operator -hand tighten. Tighten the locknutagainstthe case, to secure the nipple firmly in place. B5. Partially close the valve (3 or revolutions of the hand wheel or crank). B6. Using the special tool provided, loosen the two cover screws and remove the cover from the PCVS. 87. Loosen the locking screwthat holds the trip rod in place. Estimate trip rod length required and extend slightly paslthat poi nt. Slide the PCVS unit asfaras possible onto the nipple, observing which direction the rod will move'when the valve is closed. Orient the device to actuate switches when valve is open. NOTE: If trip rod length is excessive, loosen the locking screw and removethe trip rod from the trip lever. Using pliers, break off the one (1) inch long notched section (see Fig.7). Reinstalltrip rod and repeat Step 137procedure. B8. Remove device from nippleandwithdrawlrip rod 1132"(this dimension is important). Tighten the locking screwto hold the rod in place. Re -install thedevice on the nipple. Tighten the screwin thecellaragainstthe nipple. FIG. 7 BREAKING EXCESSIVE ROD LENGTH NOTE: In some cases it maybe necessaryto remove the gearboxcover to ensure correct operation (consultation with the valve manufacturer is recommended). B9. Carefully open the valve to its full open position, as the boss on the gear hub moves to the open position it must engage the PCVS trip rod and actuate the switch(es). There should be a minimum overtravel or revolution of the crank or hand wheel after the switch(es) actuate (a continuity meter connected to each set of contacts is one method that could be used to determine this). NOTE: Slight adjustment of gear stops may be necessary to prevent overtravel ofthe trip rod (consultationwith valve manufacture is recom- mended). B10. Carefullyclose thevalve. The switch(es) mustoperate during the first two revolutions ofthe crankorhand wheel orduring 1/5 ofthe travel distance of the valve control apparatusfrom its normal condition. B11. Completethe required electricalwiring, connections and tests. The valve should be operated through the entire cycle of fully closed and fully open to determine the integrity of the PCVS installation and signaling system. Check that all electrical and mechanical connections are secure. B12. When the installation and testing are complete, return valve to its proper position. SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL FIG.8 `\F\ +p na rms a CAUTION: An uninsulated section ofa single conductor should not be looped around the terminal and serve as two separate connections. The wire must be severed, me r 3 thereby providing supervision of the connection in the event that the wire becomes dislodged from underthe terminal. PRINTED IN USA MKT. #8820001 - REV Q PAGE 3 OF 4 9/99 (R),POTTEg ITT GRINNELLIKENNEDY INDICATING BUTTERFLY VALVE FIG. 8 PBK-PRATT IBV BUTTERFLY VALVE KIT FIG. 12 MODEL PBK-L Stock No.0090132 (MDT-4SActuator) MODELPBK-M Stock No. 0090146 (MDT-3SActuator) MODEL PBK-S Stock No. 0090133 (MDT-2SActuator) Pratt Butterfly Valve Kit as used to mount a PCVS on a Pratt Model IBV Valve. Kits contain: Bracket, nuts and instructions Note: This application is subjectlo the approval of the authority having ju dsdiction. -DRESSER-INDICATING BUTTERFLY VALVE FIG. 10 PVK - PRATT PIVA POST INDICATOR VALVE KIT (STOCK NO. 1000060) FIG. 13 MN78NE SCREW DWG. is Pratt Valve Kit as used to mount a PCVS on a PrattModel PIVAValve. Kitcontains: Instructions, template, screw and nut. Note: This application is subject lothe approval of the authority havingjudsdiclion. PCVS-1 y -2 CONTROLVALVE SUPERVISORY SWITCH TYPICAL PRESSURE REDUCER TYPE VALVE INSTALLATION FIG. 11 OOUAR rnrl�LOCKNOT NIPPLE IPPIE PCVS 16.il DWG. pan-10 This figu re shows the Model PCVS mounted on the valve yoke, with a bracket supplied by the valve manufacturer, to supervise a pressure reducer typevalve. Note: This application is subjecttothe approval of theauthority havingiurisdiction. TYPICAL ELECTRICAL CONNECTIONS Please Note: This device should be wired in accordance with the applicable parts ofthe National Electrical Code, all state and local codes, applicable NFPA Standards and the requirements of the authority having ju dsdiction. FIG. 14 EMK OanIR TO POWER FOR CON.( A N� INLICATNO MMCE L— TO SUPRVOW OaCUP 1 1 1' N.G MINDOF C1NIPOL PV CIN MMe OF NO. PF3fSfOfl ONC 4220.12 Contacts shown in normal (valve open) condition. TYPICAL SWITCH ACTION OPEN VAM FOSMON CEASW W&E POSMON CON. wa CO" N,0. aW Al I L— SW f1 ' E I cc I Na mY- I NA 99 aNA a1r dz 1 N 6 12 ONG OND-11 Switches Shown in Valve Open Position PRINTED IN USA MKT. #8820001 - REV Q PAGE 4 OF 4 9/99 VSR-F (B'POTTM VANE TYPE WATERFLOW ALARM SWITCH WITH RETARD U.S. Pat. No. 3921989 Canadian Pat. No. 1009680 Other Patents Pending Potter Electric, Rd., 1990 GENERAL INFORMATION The Model VSR-F is a vane type waterflow switch for use on wet sprinkler systems. It is UL Listed and FM Approved for use on steel pipe; schedules 10 through 40, sizes 2" thru 8". LPC approved sizes are 2" thru 8" (50mm thru 200mm). The unit may also be used as a sectional waterflow detector on large systems. The unit contains two single pole, double throw, snap action switches and an adjustable, instantly recycling pneumatic retard. The switches are actuated when a flow of 10 gallons per minute or more occurs downstream of the device. The flow condition must exist for a period of time necessary to overcome the selected retard period. ENCLOSURE: The unit is enclosed in a general purpose, die-cast housing. The cover is held in place with two tamper resistant screws which require a special key for removal. A field installable cover tamper switch is available as an option which may be used to indicate unauthorized removal of the cover. See bulletin no. 5400775 for installation instructions of this switch. UL, ULC and CSFM Listed, FM and LPC Approved, NYMEA Accepted, CE Marked Service Pressure: Up to 450 PSI Minimum Flow Rate for Alarm: 10 GPM Maximum Surge: 18 FPS Contact Ratings: Two sets of SPDT (Form C) 15.0 Amps at 125/250VAC 2.0 Amps at 30VDC Resistive Conduit Entrances: Two knockouts provided for 1/2" conduit Environmental Specifications: • Suitable for indoor or outdoor use with factory installed gasket and die-cast housing. • NEMA4/IP54Rated Enclosure - use with appropriate conduit fitting. • Temperature Range: 40°F/120°F, 4.5°C/49°C • Non -corrosive sleeve factory installed in saddle. Caution: This device is not intended for applications in explosive environments. Sizes Available: Steel Pipe schedules 10 thru 40, sizes 2" thru 8" BS 1387 pipe 50mm thru 200mm Note: For copper or plastic pipe use Model VSR-CF. Service Use: Automatic Sprinkler NFPA-13 One or two family dwelling NFPA-13D Residential occupancy up to four stories NFPA-13R National Fire Alarm Code NFPA-72 Optional: Cover Tamper Switch Kit, Stock No. 0090018 INSTALLATION: See Fig.2 These devices may be mounted on horizontal or vertical pipe. On horizontal pipe they should be installed on the top side of the pipe where they will be accessible. The units should not be installed within 6" of a fitting which changes the direction of the waterflow or within 24" of a valve or drain. Drain the system and drill a hole in the pipe using a circular saw in a slow speed drill. The 2" (50mm) and 2 1/2" (65mm) devices require a hole with a diameter of 1 1X' + 1/8" - 1/16" (33mm 32mm). All other sizes require a hole with a diameter of 2" ±118" (50mm ±2mm). Clean the inside pipe of all growth or other material for a distance equal to the pipe diameter on either side of the hole. Roll the vane so that it may be inserted into the hole; do not bend or crease it. Insert the vane so that the arrow on the saddle points in the direction of the waterflow. Install the saddle strap and tighten nuts alternately to an eventual 50 ft- Ibs. of torque (see Fig. 2). The vane must not rub the inside of the pipe or bind in any way. Specifications subject to change without notice. Potter Electric Signal Company • 2081 Cmig Road, St Louis, MO, 63146-4161 • Phone: BOD-3253936/Canada 888-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8800001- REVS PAGE 1 OF 2 MFG. #5400761-7/00 (P)POTTER FIG. 1 SWITCH TERMINAL CONNECTIONS CLAMPING PLATE TERMINAL PR. #923-3 CAUTION: An uninsulated section of a single conductor should not be looped around the termi- nal and serve as two sepa- rate connections. The wire must be severed, thereby providing supervision of the connection in the event that the wire becomes dislodged from under the terminal. FIG. 2 RETARD ADJUSTMENT. TO CHANGE TIME TURN KNOB (EITHER DIRECTION) FOR DESIRED TIME DELAY. USE THE MINIMUM AMOUNT OF RETARD NECESSARY TO PREVENT FALSE ALARMS. A "S� SETTING IS USUALLY ADEQUATE FOR THIS. FACTORY Is SET TO "8", TO INSTALL, DRILL A HOLEAS INDICATED: PIPESIZE HOLESIZE 2"to 21/2" 11/4"+1l8"-1/16" (50mmtO65mm) (33mm±2mm) 31,lo 8" 2"±1/8" (80mmto200mm) (50mm±2mm) OWG, g751-30 VSR-F VANE TYPE WATERFLOW SWITCH WITH RETARD 00 NOT LEAVE COVER OFF FOR EKTENDED PERIOD OF TINE TIGHTEN NUTS ALTERJATELY TO AN EVENTUAL 50FT.-LBS OF TORQUE MOUNT ON PPE SO ARROW ON SADDLE POINTS IN DIRECTION OF WATERFLOW ROLL PADDLE IN OPPOSITE DIRECTION OF WATERFLOW APPROX. RETARD SETTINGS (IN SECS.) 0 0 A ID-TS a 20-40 C M-55 0 50-70 E 60-e0 FIG.3 TYPICAL ELECTRICAL CONNECTIONS NOTES` FIG.4 1. The Model VSR-F has two To remove knockouts: Place 2 sErs or switches, one can be used to screwdriver at edge of knock- N°RNALLr OPEN DDNmc1s C1°SE ON AIARN WATERFLOWZONEROM operate a central station, pro- outs, not in the center. ON prietary or remote signaling 3 unit, while the other contact Is used to operate a local audible or visual annunciator. n 2. A condition of LPC Approval of this product is that the electri- cal entry must be sealed to ND AND ND M P15ON exclude moisture. E MR ON 7HE SNTICN ARE FOR �AE�°0��® NEa3�' 3. For supervised circuits see o Q e Doxrp� WHEN 1HE DEUCE IS IN t�t11RA1 AC n•+-, "Switch Terminal Connec- o THE NORMAL 00N0m0N tions' drawing and caution note (Fig. 1). APPLICATION WARNINGI Due to the possibility of unintended discharges caused by pressure surges, trapped air, or short retard times, waterflow switches that are monitoring wet pipe sprinkler systems should not be used as the sole initiating device to discharge AFFF, deluge, or chemical suppression systems. TESTING The frequency of inspection and testing for the model VSR-F and its associated protective monitoring system should be in accordance with applicable NFPA Codes and Standards and/or the authority having jurisdiction (manufacturer recommends .quarterly or more frequently). If provided, the inspector's test valve, that is usually located at the end of the most remote branch line, should always be used for test purposes. If there are no provisions for testing the operation of the flaw detection device on the system, application of the VSR-F is not recommended or advisable. A minimum flow of 10 gpm is required to activate this device. IMPORTANT NOTICE: Please advise the person responsible for testing of the fire protection system that this system must be tested in accordance with the testing instructions. PRINTED IN USA MKT. #8800001-REVS PAGE 2 OF 2 MFG.#5400761-7/00 (E),POTTER BELLS PBA-AC & PBD-DC UL Listed, FM Approved Sizes Available: 6" (150mm), 8" (200mm) and 10" (250mm) Voltages Available: 24VAC 120VAC 12VDC (10.2 to 15.6) Polarized 24VDC (20.4 to 31.2) Polarized Service Use: Fire Alarm General Signaling Burglar Alarm Environment: Indoor or outdoor use (See Note 1) 40" to 150"F (400 to 66°C) (Outdoor use requires weatherproof backbox.) Termination: 4 No. 18 AWG stranded wires 6" BELL SHOWN Finish: Red powder coating Optional: Model BBK-1 weatherproof backbox These vibrating type bells are designed for use as fire, burglar or general signaling devices. They have low power con- sumption and high decibel ratings. The unit mounts on a standard 4" (101 mm) square electrical box for indoor use or on a model BBK-1 weatherproof backbox for outdoor applications. Weatherproof backbox model BBK-1, Stock No. 1500001. ALL DC BELLS ARE POLARIZED AND HAVE BUILT-IN TRANSIENT PROTECTION: size INCHES (mm) VOLTAGE MODEL NO. STOCK NO. CURRENTAT ((MAX.) TYPICAL dB 10 (am) (2)2) MINMUMdB AT (1) (9mI 11I 6(150) 12VDC PBD126 170N12 .12A 85 76 8(200) 12VDC PBO128 1708012 .12A 90 76 10(250) 12VDC PBD1210 1710012 .12A 92 76 6(150) 24VDC PBD246 1706024 .06A 87 76 8 (200) 24VDC PBD248 17MG24 .06A 91 79 10(250) 24VDC PBD2410 1710024 .06A 94 79 6(150) 24VAC PBA246 1806024 .17A 91 76 8(200) 24VAC PSA246 1808024 .17A 94 76 10(250) 24VAC PBA2410 1BICO24 .17A 94 76 6(150) 120VAC PBA1206 1806120 .05A 92 82 8(200) 120VAC PBA1208 1808120 .05A 99 82 10(250) 120VAC PSA120U) 1 1810120 ASA 99 85 Notes: 1. Minimum d6 ratings are calculated from integrated sound pressure measurements made at Underwriters Laboratories as specified in UL Standard 464. UL temperature range is -30" to 150"F (-34° to 66"C). 2. Typical dB ratings are calculated from measurements made with a conventional sound level meter and are indicative of output levels in an actual installation. Potter Electric Signal Company • 2081 Craig Road, SL Louis, MO, 63146-4161 • Phone: B00-325-3936/Canada 905-882-1833 • www.pottersignal.com PRINTED IN USA MKT. #8850001-REV P PAGE 1 OF 2 MFG. #5400776 -3/99 (BPOTTER BELLS PBA-AC & PBD-DC DIMENSIONS INCHES (mm) FIG.1 BELLS FIG.2 WEATHERPROOF BACKBOX BOX HAS ONE THREADED 1/2" CONDUIT ENTRANCE 5' (127) DWG. #776-1 FIG. 3 WIRING (REAR VIEW) D.C. BELLS (OBSERVE POLARITY) RED (IN) ROD (OUT) FROM CONTROL PANEL CDR BELL FI OR -LINE PRECEDING BELL R BLACK (IN) CAUTON: Jc WHEN ELECTRICAL SUPERMSION IS REQUIRED USE IN AND OUT LENDS AS SHOWN. W NOTES: 1. OBSERVE POLARITY TO RING O.C. BELLS. 2. RED WIRES POSITIVE (+) 3. BLACK WIRES NEGATIVE (-) DING. #776-3 DWG. 1776-2 4 1 /4" (108) INSTALLATION 1. The bell should be mounted a minimum of 8 ft. (2.4m) from the floor or as close to the ceiling as possible. 2. Remove the gong. 3. Connect wiring (see Fig. 3). 4. Mount bell mechanism to backbox (bell mechanism must be mounted with the striker pointing down). 5. Reinstall the gong (be sure that the gong positioning pin, in the mechanism housing, is in the hole in the gong). 6. Test all bells for proper operation and observe that they can be heard where required (bells must be heard in all areas as designated by the authority havingjurisdicticn). PRINTED IN USA MKT. #8850001-REV P PAGE 2 OF 2 MFG.#5400776-3/99 Fire Department Connection, 90 Degree Pattern Description. The 90 Degree Fire Department Connection is Underwriters' Laboratories listed and Factory Mutual Approved. Manufactured from solid brass components to increase service life. The single clapper design features brass clapper and brass seats within a cast brass body. The 2 1/2" swivels are pin lug design for ease of use and compatibility with local fire service districts. Swivel gaskets are included. Installation Installation of the Fire Depart- ment Connection is achieved with readily available job site tools. Prior to installa- tion make sure the proper identification sign has been installed on the nipple. Coat male threads of 4" IPS nipple liberally with a suitable pipe thread sealant such as Pipefit®. Tighten FDC one 01995-2008 Fire Protection Products, Inc (FPPI) full turn past hand tight. Make sure FDC is aligned accord- ing to requirements. DO NOT OVER TIGHTEN. OVERTIGHTENING MAY CAUSE SEVERE STRETCH- ING AND POSSIBLE CRACKING OF THE OF THE FDC BODY. Speaffications Size: 4" IPS Inlet (2) 21/2" Swivel Outlets Type: 90 Degree Pattern Material: Brass Swivels: 21/2" NST BCT ONT QST PHX TEM CLV__ Approvals: UL Listed 300psi FM Approved 300psi Fire Protection Products, Inc F P P 'a 6241 Yarrow Dr., Suite A, Cadsliad, CA 92011-1541 " For questions: 1 800 344-1822 • 1 800 344-3775 fax • www.fopi.com Applications • Fire sprinkler systems • Suitable for all media that will not obstruct the pressure system or attack copper alloy parts Special Features • UL-listed (UL-393), United States and Canada • Factory Mutual (FM) approved • Reliable and economical Standard Features Design EN 837-1 & ASME B40.100 Sizes 4• (100 mm) Accuracy class t 3/2/3% of span (ASME B40.100 Grade B) Ranges 0/80 psi, retard to 250 psi (air) 0/300 psi (water or air) Working Pressure Steady: 3/4 of full scale value Fluctuating: 2/3 of full scale value Short time: full scale value Operating Temperature Ambient: -40OF to 140OF (-40°C to 60°C) Media: 140°F (+60°C) maximum Temperature Error Additional error when temperature changes from reference ter- perature of 68°F (20°C) +0.4% for every 18OF (100C) rising or falling. Percentage of span. 02008 Fire Protection Products, Inc (FPPI) A• c �I Er I E e W(w) Dimensions (N?T) 4" mm 100 83.5 30 11.5 3.75 14 in 4,0; 3.ZR 118 0.45 0:15 1/47' 0.5& 0.36'lb? Bourdon Tube Material: copper alloy C-type Pressure Connection Material: copper alloy 1/40 NPT lower mount (LM) Movement Copper alloy Dial White aluminum with stop pin; black and red lettering Pointer Black aluminum Case Black polycarbonate Window Snap -in clear polycarbonate Optional Extras (not all options are UL or FM approved) • Brass restrictor • Friction -fit cover ring (requires steel case) • Glass window (requires' steel case & friction ring) • Black -painted steel case • Stainless steel case • Special case colors • Nickel -plated connection • Custom dial layout • Special threaded connection • Custom dial layout • Other pressure scales available: bar, kPa, MPa, kg/cm2 and dual scales Approvals UL listed (UL-393) Factory Mutual FM MPROM c &us jFire Protection Products, Inc usTea F P P ' ® 6241 Yarrow Dr., Suite A, Carlsbad, CA 92011-1541 For questions: 1 800 344-1822. 1 800 344-3775 fax • www.fppi.com System No. C-AJ-1353 F Rating - 3 Hr T Rating - 0 Hr L Rating At Ambient - Less Than 1 CFM/sq ft L Rating At 400°F - Less Than 1 CFM/ sq ft Section A -A 1. Floor or Wall Assembly - Lightweight or normal weight (100-150 pcf or 1600-2400 kg/m3) concrete floor or wall. Min thickness of concrete is shown in table in Item 4B.. Floor may also be constructed of any min 6 in. (152 mm) thick hollow -core Precast Concrete Units'. Wall may also be constructed of any UL Classified Concrete Blocks'. Max diam of opening is 14 in. (356 mm). Max diam of opening in floors constructed of hollow -core is 7 in. (178 mm). See Concrete Blocks (CAZT) or Precast Concrete Units (CFTV) categories in the Fire Resistance Directory for names of manufacturers. 2. Steel Sleeve - (Optional) - Nom 14 in. (356 mm) diam (or smaller) Schedule 10 (or heavier) steel pipe cast or grouted into floor or wall assembly. Steel sleeve may be installed flush or may project a max 2 in. (51 mm) beyond the floor or wall surfaces. 3. Through Penetrant - One metallic pipe, conduit or tube to be installed eccentrically or concentrically within the firestop system. The annular space between the pipe, conduit or tube and the periphery of the opening shall be min 0 in. (point contact). The max annular space is 1 in, or 2 in. (25 or 51 mm) as shown in the table in Item 4B. Pipe, conduit or tube to be rigidly supported on both sides of the floor or wall assembly. The following types and sizes of metallic pipes, conduits and tubes may be used: A. Steel Pipe - Nom 12 in. (305 mm) diam (or smaller) Schedule 5 (or heavier) steel pipe. B. Iron Pipe - Nom 12 in. (305 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 6 in. (152 mm) diam (or smaller) rigid steel conduit, nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT) or nom 4 in. (102 mm) diam (or smaller) flexible steel conduit: D. Copper Pipe - Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe. E. Copper Tube - Nom 4 in. (102 mm) diam (or smaller) Regular L (or heavier) copper tube. 3A. Through Penetrating Product" - Flexible Metal Piping - As an alternate to Item 3, one nom 2 in. (51 mm) diam (or smaller) flexible steel pipe (with or without plastic jacketing) to be installed either concentrically or eccentrically within the firestop system. The annular space between the pipe, conduit or tube and the periphery of the opening shall be min 0 in. ( 0 mm or point contact). The max annular space is 1 or 2 in. (25 or 51 mm) as shown in the table in Item 4B. Pipe to be rigidly supported on both sides of the floor or wall assembly. 'M i STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. ul Created or Revised: May 23, 2008 ® ` (800)992-1180 • (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Website:vnwa.s8fireslop.com AGE 1 OF 2 0 OMEGA FLEX INC GASTITE, DIV OF TITEFLEX WARD MFG INC 4. Firestop System - The firestop system shall consist of the following: A. Packing Material - When required as shown in the table in Item 4B, min 4 pcf (64 kg/m3) mineral wool batt insulation compressed and tightly packed to min 2-1/4 in. (57 mm) thickness. Packing material recessed from top surface of floor or both surfaces of wall as required to accommodate fill material (Item 413). When packing material is shown as being optional, mineral wool or glass fiber insulation or polyethylene foam backer rod may be used as a permanent form to facilitate installation of the fill material. In floors constructed of hollow -core precast concrete units, packing material to be recessed from both top and bottom surfaces of floor, as required to accommodate fill material (Item 4B). When steel sleeve projects from top of floor or from both sides of wall, the thickness of mineral wool batt packing material should be increased by an amount equal to the distance that the sleeve extends past the floor or wall surface. B. Fill, Void or Cavity Material' -Sealant - Fill material applied within annulus, flush with top surface of floor assembly or top edge of steel sleeve. In walls and in floors constructed from hollow core precast concrete units, fill material applied symmetrically on both sides of assembly flush with wall/floor surfaces or both ends of steel sleeve. At point contact location, apply min 1/4 in. (6 mm) diam bead of fill material at pipe/concrete interface or pipe/steel sleeve interface on top surface of floor or both surfaces of wall or precast concrete units. The fill material thickness shall be as specified in the following table: Min Concrete Thickness, In. (mm) Steel Sleeve Max Annular Space, in. (mm) packing Material Min Fill Material Thfckness in. (mm) F Rating 2-1/2 (64) Optional 2 (51) Required 1/4 (6) 3 hr 4-1/2 (114) No 1 (25) Optional 1/2 (13) 2 hr SPECIFIED TECHNOLOGIES INC - SpecSeal LCI Sealant 'Bearing the UL Classification Mark I STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. ul Created or Revised: May 23. 2008 ® L (800)992-1180 . (908)526-8000 • FAX (908)231-8415 • E-Mail:techserv@stifirestop.com • Websitevw .stifirestop.com AGE 2 of 2 System No. W-L-1222 F Ratings -1 and 2 Hr (See Item 1) T Ratings -1/4, 3/4 and 1 Hr (See Item 2) L—A 1tL �Lt 18 Section A -A Wall Assembly -The 1 or 2 hr fire -rated gypsum board/stud wall assembly shall be constructed of the materials and in the manner specified in the individual U300 or U400 Series Wall or Partition Design in the UL Fire Resistance Directory and shall include the following construction features: A. Studs -Wall framing may consist of either wood studs or steel channel studs. Wood studs to consist of nom 2 by 4 in. (51 by 102 mm) lumber spaced 16 in. (406 mm) OC. Steel studs to be min 3-1/2 in. (89 mm) wide and spaced max 24 in. (610 mm) OC. B. Gypsum Board' -Thickness, type, number of layers and fasteners as specified in the individual Wall and Partition Design. Max diam of opening is 10-5/8 in. (270 mm). The hourly F Rating of the firestop system is equal to the hourly fire rating of the wall assembly in which it is installed. 2. Through Penetrant - One metallic pipe, conduit or tube to be installed eccentrically or concentrically within the firestop system. Pipe, conduit or tubing may be installed at an angle not greater than 45 degrees from perpendicular. The annular space between the pipe, conduit or tube and the periphery of the opening shall be min 0 in. (0 mm, point contact) to max 2 in. (51 mm). Pipe, conduit or tube to be rigidly supported on both sides of the wall assembly. The following types and sizes of metallic pipes, conduits and tubes may be used: A. Steel Pipe - Nom 8 in. (203 mm) diam (or smaller)Schedule 5 (or heavier) steel pipe. B. Iron Pipe - Nom 8 in. (203 mm) diam (or smaller) cast or ductile iron pipe. C. Conduit - Nom 6 in. (152 mm) diam (or smaller) rigid steel conduit, nom 4 in. (102 mm) diam (or smaller) steel electrical metallic tubing (EMT) or nom 4 in. (102 mm) diam (or smaller) flexible steel conduit. D. Copper Pipe - Nom 4 in. (102 mm) diam (or smaller) Regular (or heavier) copper pipe. E. Copper Tube - Nom 4 in. (102 mm) diam (or smaller) Type L (or heavier) copper tube. Type of Penetrant Max Diam T Rating Steel or iron pipe, steel 2 in. (51 mm) 1 hr conduit or EMT Steel or iron pipe, steel a In. (203 mm) 314 hr conduit or EMT Copper pipe ortube 4 in. (102 mm) 114 hr 2A. Through Penetrating Product" - Flexible Metal Piping -As an alternate to Item 2, one nom 1-1/4 In. (32 mm) diam (or smaller) steel flexible _ metal pipe to be installed either concentrically or eccentrically within the firestop system. The annular space between the pipe and the periphery of the opening shall be min 0 in. (0 mm, point contact) to max 2 in. (51 mm). Pipe to be rigidly supported on both sides of the wall assembly. OMEGA FLEX INC _I TITEFLEX CORP A BUNDY CO WARD MFG INC -i 3. Fill, Void or Cavity Material* - Sealant - Min 5/8 in. (16 mm) thickness of fill material applied within annulus, flush with both surfaces of wall assembly. At point contact location, min 1/4 in. (6 mm) diam bead of fill material applied at metallic pipe/gypsum board interface on bath surfaces of wall. SPECIFIED TECHNOLOGIES INC-SpecSeal LCI Sealant *Bearing the UL Classification Mark i STI Specified Technologies Inc. 200 Evans Way Somerville, NJ 08876 Reproduced courtesy of Underwriters Laboratories, Inc. Created or Revised: July 26, 2006 L & W L 1222 (800)992-1180 - (908)526-8000 - FAX (908)231-8415 - E-Mail:techserv@stifirestop.com - WebsitevNAv.stifirestop.com PAGE 1 OF 1