Loading...
HomeMy WebLinkAboutNOAMIAMIM E MIAMI-DADE COUNTY, FLORIDA METRO -DARE FLAGLER BUILDING BUILDING CODE COMPLIANCE OFFICE (BCCO) SCANNED 140 WEST FLAGLER STREET, SUITE 1603 PRODUCT CONTROL DIVISION BY MIAM,I,. FLORIDA33130.1563 (NOA) St. Lucie County (305) 375-2901 FAX (305) 372-6339 NOTICE OF ACCEPTANCE rnvw.miamidade.gov/buildinacode Best Rolling Doors, Inc. 9780 NW 791h Avenue Hialeah Gardens, FL 33016 SCOPE: IQ This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Model S10-6565 Steel Roll -up Door APPROVAL DOCUMENT: Drawing No. 6565_2009_02, titled "Model S 10-6565', sheets 1 through 3 of 3, dated 04/06/09, prepared by Best Rolling Door, Inc, signed and sealed by Joseph H. Dixon, Jr, P.E., bearing the Miami -Dade County Product Control approval stamp with the Notice of Acceptance number and approval date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA consists of this page 1 and evidence page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Carlos M. Utrera, P.E. NOA No. 09-1103.05 Expiration Date: January 27, 2015 Approval Date: January 27, 2010 J I7/10 Page 1 Best Rolling Doors, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. 6565_2009_02, titled "Model S 10-6565", sheets 1 through 3 of 3, dated 04/06/09, prepared by Best Rolling Door, Inc, signed and sealed by Joseph H. Dixon, Jr., P.E. B. TESTS 1. Test reports on 1) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 2) Large Missile Impact Test per FBC, TAS 201-94 3) Cyclic Wind Pressure Loading per FBC, TAS.203-94 4) Tensile Test per ASTM A370-05, Along with marked -up drawings and installation diagram of Model S 10-6565 Steel Garage Doors, prepared by Fenestration Testing Laboratory, hic., Test Report No. FTL # 5589, dated 01/13/09, signed and sealed by Michael R. Wenzel, P.E. C. CALCULATIONS 1. Calculations for attachment of "C" channel guide to steel or concrete jamb, dated 07/23/09, prepared, signed and sealed by Joseph H. Dixon, Jr., P.E. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 07-1107.08, issued to Dyplast Products, LLC, for their Expanded Polystyrene Block Type Insulation, approved on 02/28/08 and expiring on 01/11/12. F. STATEMENTS 1. Statement letter of code conformance, dated 10/16109, signed and sealed by Joseph H. Dixon, Jr., P.E. 2. Statement letter of no financial interest, dated 10/16/09, signed and sealed by Joseph H. Dixon, Jr., P.E. Carlo M. Utrera, P.E. Product Control Examiner NOA No. 09-1103.05 Expiration Date: January 27, 2015 Approval Date: January 27, 2010 E -1 MI®=ME BUILDING CODE COMPLIANCE OFFICE (BCCO) PRODUCT CONTROL DIVISION NOTICE OF ACCEPTANCE Daybar Industries Limited 50 West Drive, Brampton, Ontario, Canada L6T 2J4 MIAMI-DADE COUNTY, FLORIDA METRO-DADE FLAGLER BUILDING 140 WEST FLAGLER STREET, SUITE 1603 MIAMI, FLORIDA 33130-1563 (305) 375-2901 FAX (305) 375-2903 www.miamidade.gov/buildingcode IZ.I Zoizo IV SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed by Miami -Dade County Product Control Division and accepted by the Board of Rules and Appeals (BORA) to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Division (hi Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. BORA reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Division that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code, including the High Velocity Hurricane Zone. DESCRIPTION: Series "LS-18" Outswing Commercial Steel (Galvanneal or Stainless) Doors w/ 16 ga Frames & w/wo Panic Exit Device-LM Impact APPROVAL DOCUMENT: Drawing No "09-030", titled "Double & Single LS18 Outswing Commercial Galvanneal or Stainless Steel Doors w/ Series"AS"16 ga Steel frames", sheets 1 through 3, 3A and 4 thru 19 of 19 prepared by Tilteco Inc, dated MAR 17, 2009, signed and sealed by Walter A. Tillit Jr. , P. E., bearing the Miami - Dade County Product Control Renewal stamp with the Notice of Acceptance number and expiration date by the Miami -Dade County Product Control Division. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant Limitations: 1. Glazed vision liter are limited per sheet 8. 2. Min edge distance required for ITW 3/16" Tapcon (item #22) is 2-5/8" and for Power 5/16-18 caulk -in anchor is 3-3/4". LABELING: Each unit shall bear a pennancnt label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded- by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA # 09-0323.21(06-0117.01) consists of this page 1 and evidences page E-1, as well as approval document mentioned above. The submitted documentation was reviewed by Ishaq I. Chanda, P.E. MIAMI•DADECOUNrY ,.= NOA No 10-0217.05 Expiration Date: April 07, 2015 Approval Date: May 05, 2010 Page 1 Daybar Industries Limited ' NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED A. DRAWINGS (transferred from file # 09-0323.21) 1. Manufacturer's parts and sections drawings (transferred from file # 05-0620,06) 2. Drawing No "09-030", titled "Double & Single LS18 Outswing Commercial Galvanneal or Stainless Steel Doors w/ Series"AS"16 ga Steel frames", sheets 1 through 3, 3A and 4 thru 19 of 19 prepared by Tilteco Inc, dated MAR 17, 2009, signed and sealed by Walter A. Tillit -- Jr., P. E. B. TESTS (transferred from file # 09-0323.21) 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 (except sp# 7 louver) 2) Uniform Static Air Pressure Test, Loading per FBC, TAS 202-94 3) Water Resistant Test, per FBC, TAS 202-94 (except sp# 7 louver) 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411.3.2.1 (b) and TAS 202-94 Along with marked -up drawings and installation diagram of outswing steel door, prepared by Hurricane Testing Laboratory, LLC, Test Report No. HTL-0279-0719-03 dated 07-16 thru 08-18-2003 for specimen 1, 2, 3, 7 & 7 EMB, signed and sealed by Vinu J. Abraham, P.E. Note: The above test report has been revised with addendum letters dated Dec 16, 2004 and a revised marked -up drawing issued on 12-15-2004 by Hurricane Testing Lab, signed and sealed by Vinu J. Abraham, P.E. C. CALCULATIONS: (transferred from file # 09-0323.21) 1. Anchor Verification Calculations, complying w/ FBC-2007, dated 03/17/09, prepared, signed and sealed by Walter A. Tillit Jr., P. E. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO). E. MATERIAL CERTIFICATIONS (transferred from file # 05-0620.06) 1. Tensile Test report No. Job# 0279-0719-03, dated March 02, 2004, issued by Q C Metallurgical, Inc, per ASTMS-8, signed & sealed by Frank E. Grate, P.E. 2. Notice of Acceptance No. 07-1107.08 issued to Dyplast Product, LLC (Former Apache Products Co.) for "EPS-Expanded Polystyrene Insulation", expiring on 01/11/12. 3. Notice of Acceptance No. 08-0305.02, issued to SABIC Innovative Plastic (Former G.E. Plastic) for "Lexan Sheet Product", expiring on 07/17/2013. F. STATEMENTS (transferred from file # 09-0323.21) 1. Statement letter of compliance to FBC-2007 and "No financial interest, both dated April 29, 2009, signed by Walter A. Tillit Jr., P. E. 2. Facsimile correspondence dtd Nov. 14, 2005 from DAYBAR, requesting substitution of Stainless Steel in lieu of Galvanneal Steel & BCCO response dated 11/23/05. 3. Statement letter of compliance issued by Hurricane Testing Laboratory LLC:, as part of above referenced test report. G. OTHER 1. This NOA renews NOA # 09-0323.21(06-0117.01), expiring April 07, 2010. 2. Material properties data sheet of AISI 304 Stainless Steel. 2. Manufacturer/Distributor agreement between Daybar Industries Ltd. & Daybar Southeast Service Centre, signed by respective officials (original in le #04-0818.02). shaq I. Chanda, P.E. Product Control Examiner NOA No 10-0217.05 Expiration Date: April 07, 2015 Approval Date: May 05, 2010 E-1