Loading...
HomeMy WebLinkAboutPROPANE TANK PAPERWORKQuality Steel Corporation AG/UG Propane Tanks tEn wlpM 1450 wg. AND UP APPROXIMATE ABOVEGROUND/UNDEGROUND (AG/UG) VESSEL DIMENSIONS AND SCANNED BY St. Lucie County WATER CAPACITY DIAMETER OD) HEAD TYPE OVERALL LENGTH OVERALL HEIGHT LEG' WIDTH LEG** SPACINGAlbs.) WEIGHT •=QUANTITY Fuu.wAD PERSTACK 120wg. 24 Ellip. 5 8 3 1 11/2 or3'-11" 260 308196 16112 `250 wg. 30" Hemi. 7'40" 3'-8" 1'-5" 4'-11" 480 S4 9 •320wg, 30" Heml. 9'-7"_ 31-8u. 1'-5" 5' 620 45 9 500wg. 371/2"' Hemi. 10, 4'-2" 1'-8" 5' 950 37130 816 1000wg. 41" Hemi. 16' 4'-5" 1'-8" 10'-1" 1,800 17115 615 1450 wg. 461/2" Ellip. 17'4" 4'-11" 1'-9" 11'-7" 2,650 12 4 1990 wg. 461/2" Ellip. 23'-11" 4'-11" 1'-9" 16' 3,520 8 4 Dimensions and specifications shown are apprmdmate. ftnlMdml vessels rnWwry. • Irgs adngi/-Y. legwiddss and sparing mayvarybased on mtg. location. check with yotvsalesperson for detalls. 1206 250,320 wg. standard tanks -no holes to legs (one center hole on request). 500 and 1000 wg. standard tanks- 2 holes 16' on renter. U50 wg. and up asshown above. "Full lmd andstark quarditu varybyshlpping loratlon-. Oiukwith yoursalesperson fordetall& General Soec'dicat(ons - Conforms to the latest edition of ASME Rules for Construction of Pressure Vessels, Section Vill, Division 1. Compiles with NFPA 58. - Rated at 250 psig from -20' F to 125' F. All vessels registered with National Board. - -Two service options available: - - Option 1: Ready -to -bury underground option, coated with either powder coated phenolic epoxy finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with composite AG/UG dome. Option 2: Aboveground option, coated with either powder coated TGIC polyester finish or liquid applied epoxy primer coat followed by urethane top coat, supplied with steel AG/UG dome. -All vessels are shipped vacuum pre -purged to enable simplified first fill of the vessel. Updated June 30, 2015 i . TlvWA*eftAALA9W J�::_':ii..-'i!I•'�.ij'i.^-IIi�-I �• ' . � raid •- - ass awa�r J4• L. ::1� it , i ,i. �tAM Ti� �• f Fr'r�.�'rr,� :.v, 4 PROPANE CONSTRUCTION NOTES 1. All pipe and fittings above ground and Inside building shall be SCH..40 Galvanized' ASTM A120. or AGA approved.corru'gated stainless Meel•(C.S.S.T.)-pipe'. 2. All polypipe and ft"gs shall be ASTM D25f3 or ASTM D2517 and shah be burlec! aufside underground at a depth of 18" with warning tape and tracer wire. 3. All pipe and meter locations are approximate and subject to change.. .4 Ali polypipe shall be joined by heat fusion or approved mechanical. couplings. 5. All -galvanized pipe shall be threaded. 6: All pipe. shall be pressure tested to. 201 PSI for- a period of 24 hours. /y UNDER ROUND) TANK INSFALLATIOR / 2" to G" DOWNGRADED AWAY FROM DOME _• i --- • Sri, :� t r j ANODE CABLE. SACRJFICIAL ANODE (MAGNESIUM S Gj • s • 'Ilx � � • 9!' . n REGGLATOR�rr SHUT OAS OFAT ' 01J fDE VALFVE 7 IN A O E GRADE �sl' ' SEER HARN 1!G TAPE . -. \\ Y • RISER GRADE/CQHCRETE SLEEVE . It • uNoenonoYtlok" CORWH9n SERVICE LINE •m • _ ?s TRACE HIRE