HomeMy WebLinkAboutEVALUATION REPORTENGINEER EVALUATE
EVALUATION REPORT
Polyglass USA, Inc.
1111 West Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1230
SCOPE:
TEST
SCANNED
BY
St. Lucie County
MEMO I etc.
Ceraj7cateofAuthorization M2455
353 Christian Street, Unit #13
Oxford,-CT06478-
(203)262-9245
CONSULT CEIMFY
Evaluation Report P12060.02.09-R24
FL5299-R28
Date of issuance:02/24/2009
Revision 24: 01/24/2018
This Evaluation Report is issued under Rule 61620-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has. been reviewed by Robert Nieminen, P.E.
for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6tb Edition (2017) Florida Building Code sections noted
herein.
DEscRIPnON: Polyglass Roof Underlayments
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Cade that relate to the product change. Acceptance of this
Evaluation Report by the named client Constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility lodation(s). NEMOIetc. requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADveansENIEW: The Evaluation Report number preceded by the words "NEMOIetc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. '
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 14.
Prepared by
pva° p; •, ,—
i
Robert J.M. Nleminen, P.E
_ •i
Florida Registration No. 59166, Florida DCA ANE29B3
The faolmile seal appearingw s authorbed by Robert Nieminen,
P.E. on 01/24/201s. This does notsetve m an electronically
signed document'
CERTIFICATION OF INDEPENDENCE:
1. MEMO etc. does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. MEMO eta is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
. which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved In the approval process of the
product.
S. This is a building code evaluation. Neither MEMO Ietc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
OONEMO[etc.
ROORNOCOMPONENTEVALUATION:
1. SCOPE:
Product Category: Rooting
Sub -Category: Underlayment
Compliance Statement: Roof Underlayments, as produced by Polyglass USA, Inc-, have demonstrated compliance with the
following sections of the & Edition (2017) Florida Building Code through testing in accordance with the following Standards.
Compliance )s subject to the installation Requirements and Limitations / Conditions of Use set forth herein.
2. STANDARDS:
- Section
Properly
ndard
year
1504.11
Wind Uplift
FM 4474
2011
1504.3.1
Wind Uplift
UL 1897.
2012
1507.2.3 / 1507.1.1
Physical Properties
ASTM D226
2009
1507.2.4/1507.L1, 1507.2.9.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012
2012
1507.11.2
Physical Properties
ASTM D6164
2011
1507.112
Physical Properties
ASTM D5222
2011
TAS130
Accelerated Weathering
ASIM D4798
2021
Entity
Examination
Reference
Date
FM Approvals (TSr 1867)
Wind Uplift
3004091
01/12/2000
PRI 0ST5878)
Physical Properties
PRIC2211
04/08/2002
PRI (TSr5878)
Physical Properties
PUS"05-02-01
01/31/2002
PRI (TST5978)
Physical Properties
PUSA-013-02-01
12/23/2002
PRI OW 5878)
Physical Properties
PUSA-013-02-02
12/23/2002 -
PRI (TST 5878)
Physical Properties
PUSA-013-02-03
12/23/2002
PRI M75878)
Physical Properties
PUSA-028-02-02
07/14/2003
PRI(TST 5878)
Physical Properties
PUSA-028-02-01
07/13/20DS
PRI(W 5878)
Physical Properties
PUSA-033-02-01
01/12/2005
PRI (TST5878)
Physical Properties
PUSA-035-02-01
09/29/2006
PRI (WW78)
Physical Properties
PUSA-055-02-02
12/30/20W
PRI (TST 5878)
Physical Properties
PUSA-061-02-02
01/28/2008
PRI (TST 5878)
Physical Properties
PUSA-076-02-M
02/22/2DD8
PRI M75979)
physical Properties
PUSA-083-02-01
04/14/2003
- PRI (TST 5878)
Physical Properties
PUSA-0 8-02-01
07/2912OW
04/01/2008
MTI XT 2508)
Physical Properties
1X20H7A
01j19/2009
MTI (Tsir 2508)
ERD (TS76049)
Physical Properties
Physical Properties
RX34E8A
11752.09.99-1
02/08/2000
END (TST 6049)
Wind Uplift
11757.08.01-1
08/23/2001
END (TST 6049)
Wind Uplift
11776.05.02
01/15/2003
07/14/2003
END CM 6049)
Physical Properties
02200.07.03
01/04/20W
END (TST 6049)
END M76049)
Wind Uplift
Physical Properties
P3740.0107
P5130.04.07-1
04/17/21107
END (TST 6049)
Wind Uplift
P9260.03.08
03/21/2008
08/13/2009
END (TST 60491
Physical Properties
Wind Uplift
. P13450.08.09
P30540.11.09-Ri
22/30/2009
END (f5T6049)
ER13 UST 6049)
Physical Properties
P11030.11.09.1
11/30/2009
END CW 6049)
Wind Uplift
P11030.11.09-2
11i30/2009
11/30/2009
END (TSi 6049)
Physical Properties
P31030.11..09.3
06/2512MO
END M76049)
Physical Properties
P33360.06.10
03/02/2011
END (TS176049)
Physical Properties
P33370.03.11
04/26/2011
END (m 9049)
Physical Properties
P33370.04.11
10/19/2011
END (TST6049)
physical Properties
P37300.10.11
Evaluation Report P12060.02.09-1124
NEMO EW- Uc-
�47✓��Aumorimtton �.
Revision 24: 0/24/20�18
poiygiass Roof Umlerlaymems:: 1934) 233-1230
Page 2 of 14
ONEW[Ojetc.
Entity __Examination._ _ — _ _ .Reference._ _ _ _ ___ .Date. _
ERB (TST 6049) Physical Properties P40390.08.12-1 08/06/2012
ERB (TST 6049) Physical Properties P40390.08.12-2 OS/U7/2012
ERB MGM) Physical Properties C41420.09.12-3 09/11/2012
ERB(TST 6049) Wind Uplift 1339680.03.13 03/04/2013
ERB (TST 6049) Physical Properties P45370.04.13 04/26/2013
ERB(TSr 6049) Wind Uplift 131738.02.07-R2 04/29/2013
ERB CM 6043) Wind Uplift 11757AA01-1-R1 04/30/2013
ERB P-ST 6049) Wind Uplift P41630.08.13 08/06/2013
ERB (TSr 6049) Wind Uplift P117SL05.03-RI 12/26/2013
ERD(r5T 6D49) Wind Uplift P1178L11.03-R3 11/26/2013
ERB MT 6049) Physical Properties P45270.OS.14 05/12/203.4
ERB M76049) Physical Properties 6020.07.14-1 09/08/2014
ERB(TST 6049) Physical Properties 6020.09.24-2 09/08/2014
ERB (TSr 6049) Physical Properties 6020.09.14-3 09/08/2024
ERB(W 60491 Physical Properties 6020.09.14-4. 09/08/2024
ERB (TST 6D49) Physical Properties 6020.09.14-5 (39/08/2014
ERB CW 6D49) Physical Properties 6020.09.14-6 09/08/2014
ERB (TST 6049) Physical Properties P46520.10.14 10/03/2014
ERB W 6049) Physical Properties P43290.10.14 10/17/2014
ERD(TST 6D49) Physical Pmperties PLYG-SC7550.03.15 03/24/201S
ERB (TST 60491 Physical Properties P40MO.04.15 04/03/2015
ERB (IST 6049) Physical Properties P44360.10.14-R1 05/18/2015
ERB (TST 6049) Physical Properties PLYG-SC8080.05.15-1. 05/20/2015
ERB (TST 6049) Wind Uplift PLYG-SCS905.05.16b1 OS/17/2M6
ERB (TST 6049) Physical Properties PLYG-WMEO.07.16 07/16/2016
ERB(M 6049) Wind Uplift PLYG-SC12025.10.16 10/12/201E
ERB (TST 6049) Physical Properties PLYG-SC13040.12.16 12/27/2016
ERB (TST 5049) Physical Properties PLYG-SC11900.03.17 03/10/2017
ERB M76049) Physical Properties PLYG.SC12115.0&17 08/08/2027
ICGES(EVL 2396) MCCompliance ESR-1697 11/02./2024
Miami-Dade(CER 1592) HVHZ Compliance NOA 14-0717-08 01/22/2015
Polyglass USA Manufacturing Affidavit Products Current 02/19/2009
Polyglass USA P/L Affidavit Mule -Hide Crass 1% 03/01/2008
Polygim USA Materials Affidavit Palystick SA Compound 08/18/2011
Ul, LLC ()JA9625) Quality Control Service Confirmation Exp.10/05/2018
4. PRODUCT DESCRIPTION:
4.1.1 Elastobase is a fiberglass reinforced, SBS modified bitumen base sheet
4.12 Mastobase P is a polyester -reinforced, SBS modified bitumen base sheet
4.1.3 Polyglass 62 Base is a fiberglass -reinforced, asphaltic base sheet
4.1.4 Polyglass APP Base is a fiberglass-relnfcirced, APP modified bitumen base sheet
4.2.1 Paiy k tVf13 or Polystick MTS PWS is a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass
fiber reinforced, surfaced with polyolefinic film surface; meets FRSA f rRI April 2012.
4.2.2 Polystick IR-Xeis a nominal 60-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with an
aggregate surface; meets ASTM D1970.
4.2.3 Poly ck TU Plus is a nominal 80-mil thick rubberized asphalt waterproofing membrane, glass fiber reinforced, with a
polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2032.
NEMO ETC, LLC Evaluation Report P12060.02D9-1174
f1Rylmre ojpudmr8oann 83245s bra EDITION (2017) FHC NON-HwHZ EVALUATION Revision 24:0018
Polyglass Roof Underlayments; (9a4) 233-2230
Page 3 of M
ONEMO]etc.
-- - 4.2.4—Poiystidr-TU-P-ts--a-nominal_130-mil-thick_rubberized-asphalt _waterproofing_membrane,_glass-fiber/polyester_
reinforced, with a granular surface; meets FRSA/TRI April 2012.
4.25 Polystick TU Max is a nominal 60-mil thick rubberized asphalt waterproofing membrane with a 190 g/m2 polyester
fabric surface; meets ASTM D1970 and FRSA/TRI April 2022.
4.2.6 Potyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and Mule -Hide SA-APP Cap Sheet (FR) are polyester .
reinforced, APP modified bitumen cap sheets; meet FRSA/TRI April 2012.
4.2.7 PoWck Dual Pro is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polyesterfabric surface; meets ASTM D1970.
42.8 Polystick Tile Pro" is a nominal 60-mil thick dual -layer rubberized asphalt waterproofing membrane,fiberglass
reinforced, with a polyester fabric surface; meets ASTM D1970 and FRSA/TRI April 2012.
4.2.9 Polystidk MU-X is a nominal 54-mil thick- dual -layer rubberized asphalt waterproofing membrane, fiberglass
reinforced, with a polypropylene film surface; meets AC388 and physical requirements of ASTM D1970 (See Section
5.8).
4.3.:. MechamwilyFastehedand/at9d"pdedLrSderlayments;' .
4.3.1 Elastoflex G TU is a polyester reinforced, modified bitumen tile underlayment composed of a sand -surfaced SBS
modified bitumen back -side and granule -surfaced APP modified bitumen top -side. Elastoflex G TU is for use as an
alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Class M) in the 'Single Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened tile roof systems or Hot Asphalt applied "Cap Sheet" in the `Two Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or adhered the roof systems.
4.32 Eiastoflex SG G and Elastoflex S6 G FR are polyester reinforced, SBS modified bitumen cep sheets; meet ASTM D6164.
Elastoflex S6 G and Elastoflex S6 G FR are for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380,
ClassM) in the "Single Ply System"from FRSA/TRI Apri12012.(04-12) beneath mechanically fastened tile roof systems.
Elastoflex S6 G Is for use as an alternate to Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/rRI
April 2012 (04-12) beneath mechaniraily fastened or adhered file roof systems. Elastoflex S6 G FR is for use as an
alternate to Hot Asphalt applied "Cap Sheet" in the 'Two Ply System" from FRSA/rRI April 2012 (04-12) beneath
mechanically fastened file roof systems.
4.3.3 Polyflex G and Polyflex G FR are polyester reinforced, APP modified bitumen cap sheets; meet ASTM D6222.
Polyflex G is for use as an alternate to Heat Applied "Cap Sheet" in the "Two Ply System" from FRSA/TRI April 2012
(04 12) beneath mechanically fastened or adhered tile roof systems. Polyflex G FR is for use as an alternate to Heat
Applied "Cap Sheet" in the `rwo Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile
roof systems.
S. LIM17fATION6:
5.1 This is a building code evaluation. Neither NEMOietc. nor Robert N(eminen, P.E. are, In any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, Is/was used for permitting or
design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report Is not for use in the HVHZ.
5.3 Fire Classification Is not part of this Evaluation Report refer to current Approved Roofing Materials Directory for fire
ratings of this product.
5.4 Polyglass Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering..
MEMO Etcp LLC. Evaluation Report P12060.02.09-RZ4
txrf�lm@oja,rthorizonuny,3Zgs3 6' MMON(2017)FaCNON-NVHZEVAWATON FL5259-RZ
Pdrglas, RoutUnder(WrnenW, (954) 733d230 Revision 24: 01/22 B
4 1
®NEMO I etc.
— -5.5- - - -Allowable Roof Covers:
Underlayment
Asphalt Shingles
Na"n Tile
-Foa"Wifle
Metal
I
Wood3hakos
&Shlnees
slate
Elastobase
Yes
Yes
Yes
Yes;
Yes;
Yes
Elastobase P
Ye!;
Yes
Yes
Yes
Yes
Yes
Poly&ss G2 Base
No
Yes
Euvsle I.-Plv.y=.)
Yes
01.she tb2-PTYsysrem)
No
No
No
PoWlass APP Base
No
Yes
tBShajnpjVsy:sM)
Yes
(BasaShMln2p1y5y )
No
�
No
No
I
Polystick MTS or MTS PUTS
Yes
Yes
No
Yes
Yes
Yes
PolystIck IR-Xe
Yes
No
No
No
Yes;
Yes
Polyst1ckTU P
No
Yes
Yes (See 55.11
No
No
No
Po[VsUckTU Plus
Yes
Yes
Yes (See 55.1) —
Yes
Yes
Yes
Po1ystIckYU Max
No
Yes
Yes (SW 3.5.1) —
Yes
No
No
Polystickl3mlPro
Yes
No
No
Yes
Yes;
Yes
Polystick'rile Pro
Yes
Yes
Yes (See5.5.2)
Yes
Yes
Yes
Polystick MU-X
Yes
No
No
Yes
Yes
Yes
ElasWftexSfiG
yes
Yes
Yes (See- �)
No
Yes
Yes I
ElastoflaxS643 FR
Yes
Yes
No
No
Yes
Yes
Elastoffex G TU
Yes
Yes
Yes (See Sal)
Na
Yes
Yes
Poylex G
Yes
Yes
Yes LS:5.5.1)
No
140
Yes
Yes
Polyflex G FR
Yes
Yes
No
Y
Yes
Polyflex SAP or SAP FR
Yes
yes
Yes (See Sall
il
Yes
Yes
Mule,111de SA-APP Cap Sheet
arsA-APP cap sheet (FR)
Yes
Yes
Yes (See 5.5.1)
No
Yes
Yes
-
5.5.1 "Foam -on Tile is limited to use of the following Approved tile adhesives If underlayment combinartions.
TAIJI
E441(Ma��[N'Of . 6. N . . ...
Adhesive
Florida Product
UnderlaVrmants
Approval
DAP Foam Touch 'n Seal StormBand RooF
FL145CS
PolystIckTU Plus, PolystickTU Max
Tile Adhesive
Dow-nleflondn'
FL22525
Polystick TU P, Palystick TU Plus, Polyflex SAP or Tile Pro
—
Polystick TU P, PoWck TU Plus, PolyStlCk TU Max, PolystickTile Pro,
ICP Adhesives PolysetO AH-160
FL6332
Elastaflex G TU, Elastoflex 56 G, Polyflex G, Polyflex SAP, Polyflex SA Cap F%
Mule -Hide SA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Polystick TU P, Polystick TU Plus, Polystick TU Max, Polystick Tile Pro,
Polystickst
TU P' Po':'b
ICP Adhesives PolvsetO RTA4
FL6276 TEI�,toii
Elastoflex G TU, Elarflex 55 G, Polyflex G, Polyflex SAP, Polyflex: SA Cap FR,
G TU El
Mule-HideSA-APP Cap Sheet or Mule -Hide SA-APP Cap Sheet (FR)
Mule -Hide
H
1 Refer to Tile manufacturer's or Adhesive Manufacturer Florida Product Approval for Overturning Moment Resistance PedbrmanC&
NEMO ETC, LLC. Eualuatlm Report P12060.02-09-R24
CerWUrte cf&WwnWt03245S G"' WITION C=71 FBC NON41VHZ EVALUATION FLSZS9-RZB
PoWlass Roof Underlayments; 1954) Z33-2230 Revision 24-.01/24/2018
Page 5 of 14
ONEMOletc.
—5.6 Allowable Substrates:-- --
5.6.1 Direct -Bond to Deck:
Polystick (all variations), Dual Pro, Tile Pro, Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet
(FR) self -adhered to: .
D New untreated plywood; ASTM D41 primed new untreated plywood; Existing plywood; ASTM D41 primed existing
plywood; New or existing, unprimed OSB, ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed
Southern Yellow Pine; ASTM D41 primed structural concrete; Huber Engineered Woods "ZIP System" Panels
(designed and Installed to meet wind loads for project).
Note: Polyglass does not require pinning of new or existing plywood or OSB sheathing. New or existing plywood or
OSB sheathing should be cleaned of all dirt and debris prior to application of Polystick membranes.
Elastoflex G TU, Elastoflex S6 G or Elastoflex S6 G FR in hot asphalt to:
D ASTM D41 primed structural concrete.
Polyflex G or Polyflex G FIR torch -applied to:
D ASTM D41 primed structural concrete.
5.6.2 Band -to -Insulation:
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) self -adhered
to:
D ASTM C1269, Type II, Class 1 polyisocyanurate or Type V polyisoryanurate-composite insulation; Dens Deck
DuraGuard; Dens Deck Prime, or SECUROCK Gypsum -Fiber Roof Board.
Elastoflex G TU, Elastoflex S5 G or Elastoflex S6 G FR In hot asphalt to:
D Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
Polyflex G or Polyflex G FR torch -applied to:
D ASTM D41 primed structural concrete; Dens Deck Prime or SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum
requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile
systems, irisulation attachment shall be designed by a qualified design professional and installed based on testing of
the insulation/underlaymentsystem in accordance with FBCSection 1504.3.1.
5.63 Bond to Mechanically Attached Base laver: _
Polystick (all variations), Polyflex SAP or SAP FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) Dual Pro or
Tile Pro self -adhered to:
D ASTM D226, Typed or II felt; Elastobase; Elastobase P or Mule -Hide Nail Base.
Elastoflex G TU, Elastoflex 56 G or Elastaflex S5 G FR In hot asphalt to:
D ASTM 0226, Type I or II felt Elestobase; Elastobase P, Mule -Hide Nail Base or Polyglass G2 Base.
Polyflex G or Polyflex G FR Larch -applied to:
D Elastobase;, Elastobase P, Mule -Hide Nail Base, Polyglass G2 Base or Painless APP Base.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under foam -on tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-22), Appendix A, Table 1, or as fisted in Section 5.6.4 herein, or as tested In
accordance with FBC Section 15043.L
NEMO ETA LLC Ewluatlon Report P12060.02A9-R24
mxfwtvgfAumwlma"nA92 6r" EDMON I2017) FRCNON-HVHZ EVAWAMON FL525"ZB
Polyglass Roof Underlayments; (9541233-2230 Revision 24: W2412018
Page 6 of 14
ONEMOJetc.
--5.6.4 --Wind-Resistance for- Underlayment Systems in Foam -On Tile Applications, FRSA/TRI April 2012-(04-12)-does not
address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment
forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not
addressed In FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the
result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure
divided by 2 (the 2 to 1 margin of safety per FBC 15049 has already been applied). Refer to FRSA/TRI April 2012 (04-
12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads.
#1 Maximum Design Pressure=-90 osF.
Deck: MIn.15/32-inch plywood to meet projectrequlremems to satisfaction of Authority Having Jurisdiction.
Primer. None
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underpyment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#2 Maximum Design Pressure =-97.5 osf:
Deck: M in. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: PGI00 or ASTM D41
Base Ply: (Optional) Polystick NITS or Polystick NITS PLUS, sell -adhered.
Underpayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Pol/flex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
1X' ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
#3 Maximum Design Pressure=-105 psh.
Deck: Min.15/32-Inch plywood to meet projectrequiremerds to satisfaction of Authority HavingJurisdiction,
Primer: WB3000
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, POlystick TU Max, Polyflex SAP, Polyflex SAP FR. Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x
SY"" ring shank nails through 32 ga., 1-5/9" diametertin caps spaced 12-Inch o.c.
N4 Maximum Design Pressure =-135 tuf:
Deck: Min.1S/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer: (Optional) PG100 orASfM D41
Base Ply: (Optional) Polystick NITS or Polystick WITS PLUS, self -adhered.
Joints: MIn. 4-inch wide strips of ElastaRex SA-V over all plywood joints.
Underlayment: Polystick TU P, PolystickTU Plus, Polystick TU Max, PoWex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), seHadhered.
#5 Maximum Design Pressure =-315 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer. PG300 or ASTM D41
Base Ply: (Optional) Polystick WITS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Pius, Polystick TU Max, Tile P% Polyffex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap
Sheet and Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#6 Maximum Design Pressure=-622.5osf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction.
Primer. PG300 orASrM D41
Undedaymerm FJastoOex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torchapplied.
#7 Maximum Design Pressure=-30.0 osf':
Deck: Min. 15/32-inch OSB to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1J5-inch long x1-inch head diameter round metal cap nails
Spacing: 6-Inch o.c. at the }inch wide side laps and 64nch o.c. at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick Mrs or Polystick NITS PLUS, selfadhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO ETG Ur_ Evaluation Report P12060.0209-1124
afflj7me oFP d;.,&vtbn& 455 6`" EOmON(ZW7) FBC NON-HVHZ EVALUATION FL5259-112a
PolyNaas Roof underlaymems; (954) 233-1230 Revision 24:01/24/2028
Page7 of 14
ONEMOJetc.
#S Maximum Design Pressure =-37.5 pse: _ -
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga. x 1.25•inch long x 3-inch head diameter round metal rap nails
Spacing: 6-inch act at the 3-inch wide side laps and 6-Inch o.c, at two (2) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, seffadhered.
Underlayment: Polysdck TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#9 Maximum Design Pressure =-37.5 osf*:
Deck:
Min. 19/324nch plywood to meet project requirements to satisfaction of Authority Having.lurisdiction.
Base Sheet:
One (1) ortwo (2) layersASTM D226, Type II felt
Fasteners:
11 ga. x1.2S-inrh longx1-inch head diameter round metal cap nails
Spacing:
6-Inch o.c at the 3-inch wide side laps and 12-inch c.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastaflex S6 G, applied in full mopping of hot asphalt.
#SO Maximum Design Pressure =-45 psfR:
Deck:
Min.19/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet-
One (1) layer ASTM D226, Type I I felt
Fasteners:
11 ga.x L25-inchx3/84nch head diameter annular ring shank reefing nails at 1-5/8-Inch diametertinops
Spacing:
flinch o.c. at the 24nch wide side laps and 4-Inch o.c. at two (2) equally spaced staggered center rows.
Base Ply:
(Optional; for use with sett -adhering underlaymem only) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), seff-adhered or Elastoflex G TU, applied in full mopping of hot asphalt
#21 Maximum Design Pressure =-45 psf":
Deck:
Min.19/32-Inch plywoodto meet project requirementsto satisfactionof Authority Having.lurisdiction..
Base Sheet:
Two (2) layers ASTM.D226, Type II felt
Fasteners:
11 ga. x 1.25-Inch longx 3/8-inch head diameter annular ring shank roofing nails at 2-5/8-Inch diametertinraps
Spacing:
9-Inch o.c. at the 2-Inchwide side laps and 94nch o.c. at two (2) equally spaced staggered center rows.
Base Ply:
(Optional; for use with selfadhering underlayment only) Polystick MTS or Polystick MTS PLUS, selfadhered.
Underlayment: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and '
Mule -Hide SA-APP Cap Sheet (FR), selfadhered or Elastaflex G TU or Elastoflex S6 G, applied in full mopping of hot
asphalt
#12 Maximum Design Pressure=-45 osf:
Deck: Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase (sanded top surfacefor hotasphalt or torrhapplied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAX% Cap Fasteners
Spacing. 9-inch o.c. at the 24nch wide side laps and 18-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in fullmopping of hot asphalt or Polyflex G, torchapplied.
#13 Maximum Design Pressure =-52.5 psf:
Deck: Min.15/324nch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet: Elastebase(sanded top surface for hot -asphalt or torch -applied rap or poly -film surface for torch -applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing: 9-Inch o.c. at the 2-Inch wide side laps and 12-Inch o.c. at two (2) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elastaflex 56 G, applied In full mopping of hot asphalt or Polyflex G, torch -applied.
#14 Maximum Design Pressure =-52S psf-'
Deck: MIn.15/32-inch plywood to meet project requlrementsto satisfactlon of Authority Havinglurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Pose (poly -film top surface)
Fasteners: Simplex Original Cap Nails
Spacing: &Inch o.c. at the 34nch wide side laps and 6-inch o.c. at four(4) equally spaced staggered center rows.
Base Ply: (Optional) Polystick MTS or Polysdck MTS PLUS, self -adhered.
Underlayment: Polystick TU P, PolystickTU Plus, Polystick TU Max, Polyflex SAP, Pelyflex SAP Fit, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
NEMO ETC, LLC. Evaluation Report P12060.02.09-R24
OuWbateofAuffi i ian#32455 6TM EDITION(20171 FBC NON-HVH2 EVALUATION FL5259-R28
Polyglass Roof Undedaymems; ISM) 233-1730 Revision 24: 01/24/2018
Page 8 of 14
ONEMO[etc.
MaximumDesiLnPressure=-52-5Dsf:_
Deck: Min. 15/32-Inch plywood to meet project requirementsto satisfaction of Authority HavingiJurisdlction.
Base Sheet: Elastobase(sanded top surface for hot -asphalt ortorchapplied cap or poly -film surface for torch -applied cap)
Fasteners: Simplex Original Cap Nails
Spacing: G-Inch o.c. at the 3-inch wide side laps and 6-inch o.c. at four (4) equally spaced staggered center rows.
Underiayment: Elastaflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#16 Maximum Design Pressure =-60 a
Deck: Min.19/32-Inch plywood to meet projectrequirements to satisfaction of Authority Hayinglurisdlction.
Base Sheet Elastobase(sanded top surface for hot -asphalt ortorehapplied cap or poly -film surface for torchapplied tap)
Fasteners 31 ga.x1.25-inch long 3/84nch head diameter annular ring shank roofing nails at 1-5/8-Inch diameter tin caps
Spacing: 8-inch o.m at the 4-inch wide side laps and 8-inch o.a at three (3) equally spaced staggered center rows.
Undedaymem: Elastoflex G TU or Elesto#ex S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#17 Maximum Design Pressure =-60osF.
Deck: Min.19/32-inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction.
Base Sheet Elastobase(sanded top surface for hotasphalt or torch -applied cap or poly -film surface for tomhapplled cap)
Fasteners: OMG#12 Standard Ronfgrip with OMG Flat Bottom Metal Plates
Spacing. 12-Inch o.c. atthe 4-Inch wide side laps and 12-inch o.c. at twc (2) equally spaced staggered center rows.
Underlaymem: Elastoflex G TU or Elastoffm S6 G, applied in full mopping of hot asphalt or Polyflex G, torch -applied.
#18 Maximum Design Pressure=-67.5Dsf:
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet Polygiass G2 Base or Polyglass APP Base (iquires use of Larch-OpplJed undarinyment)
Fasteners: 12 ga. x 125-inch longx 3/8-inch head diameter annular ring shank roofing nails at 1-5/8-inch diametertin mps
Spacing: 8-inch mm at the flinch wide side laps and 84nch o.c. at four (4) equally spaced staggered center rows.
Undedayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#19 Maximum Design Pressure=-75 osF.
Deck: Min.15/32ynch plywood to meet project requirements to satisfaction of Authority Having.lurisdiction.
Base Sheet: Polyglass G2 Base or PoWass APP Base (requires use of torch-epplied underloyment)
Fasteners: Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Galvalume Steel Plates, OMG Roofgrip#14 with
OMG Flat Bottom Plates (AccuTrac), Trufast HD with Trufast 34nch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 1D4nch o.c. atthe flinch wide side laps and 104nch o.c.atthree (3) equally spaced staggered center rows
Undedaymerd: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or tomliapplied or Polytlex G, tomh-
applied.
#20 Maximum Design Pressure=-90 osF.
Deck: Min.35/324nch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction.
Base Sheet Elastohase(sanded top surface for hot -asphalt or torch -applied cap or poly -film surfacefortorch-applied cap)
Fasteners. Simplex MAXX Cap Fasteners
Spacing: 6-inch c.c. atthe 2-inch wide side laps and G-inch o.c, attwo (2) equally spaced staggered center rows.
Underlayment: Elastaflex G TU or Elasta lex S6 G, applied in full mopping of hat asphalt or Polyflex G, torch -applied.
#21 Maximum Design Pressure=-90 Osf:
Deck; Min.15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase(sanded top surface for hotasphalt or tomhapplied cap or poly -film surface for torch -applied cap)
Fasteners: OMG #12 Standard Raofgrlp or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Flat Bottom Metal
Plates
Spacing: binch o.e at the 44nch wide side laps and 64nch o.c. at three (3) equally spaced staggered center routs.
Undedayment Elasttlflex G TU or Elastoflex S6 G. applied In full mopping of hot asphalt or Polyflex G, torch -applied.
#22 Maximum Design Pressure=-90 osE
Deck: Min.15/32-Inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elestolim(sanded top surface)
Fasteners: Trufast#12 DP orTrufast #14 HD with Trufast 3" Metal Insulation Plates
Spacing: 64nch o.c. at the 44nch wide side laps and 6-Inch o.c at three (3) equally spaced staggered center rows.
Underlayment• Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt.
NEMO ETC, LLG Evaluation Report P1206oM09-R24
OrMTaft gFAudariWffW#32455 fife EDITION 12017) FBC NON4NH2 EVALUATION F+52594M
Polyglass Roo! underlayments; (954) 233-1230 RavWon 24:01/2412018
Page 9of 14
ONEMOJetc.
#23 Maximum Design Pressure =-90 nsi
Deck: Min. 15/32-Inch plywood to meet project requirements to satisfaction ofAuthodty Having Jurisdiction.
Base Sheet: PoWass G2 Base or Polyglass APP Base (requires use ofmrch-applied underlayment)
Fasteners Dekfast #14 with Dekfast Hex plates, OMG #14 HD with OMG 3" Gahralume Steel Plates, OMG Roofgrip #14 with
OMG Hat Bottom Plates (Accufrac), Trufast HD with Tmfast 3-inch Insulation Plates or Simplex MAXX Cap
Fasteners
Spacing: 94nch o.c. at the flinch wide side laps and 9-inch o.c. at four (4) equally spaced staggered center rows.
Underlayment: Elastoflex G TU or Elastoflex S6 G, applied in full mopping of hot asphalt or torch -applied or Polyflex G, torch -
applied.
#24 Maximum Design Pressure =-97.5mfi
Deck Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 go. xL254nchx3/8•Inch head diameter annular ring shank rooflng nails at 1-5/8-inch diameter tin caps
Spacing: 44nch o.e at the 4-inch wide side laps and 4-inch o.c. at four (4) equally spaced staggered tamer rows.
Base Ply: (Optional) Polystick MTS or Polystick MTS PLUS, self -adhered.
Underayment: Palystick TU P, PolystickTU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), self -adhered.
#25 Maximum Design Pressure=-105 Dsf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction.
Base Sheet Elastobase (sanded top surface for hot -asphalt or torch -applied cap or poly -film surface fortorch-applied cap)
Fasteners: Simplex MAXX Cap Fasteners
Spacing•. &Inch o-c at the 2-Inch wide side laps and 6-inch o.c. at three (3) equally spaced staggered center rows
Undedayment: Elastoflex G TU or Elastollex S6 G, applied in full mopping of hot asphalt or Polyflex G, torchappiled.
#26 Maximum Design Pressure=-1125 osf.
Deck: Min. 39/32-Inch plywood to meet project requirements to satisfaction of Authority Havinglurisdiction.
Base Sheet: Elastobase or Mule -Hide Nail Base (poly -film top surface)
Fasteners: 11 ga.x1.25-inchx3/84nch head diameter annular ring shank roofing nails at 1-5/8-inch diameter tin caps
Spacing: 6-Inch ac at the flinch wide side laps and 6-inch ac. at four (4) equally spaced staggered center rows.
Primer. PG300 orASfM 041 primer at all tin -caps
Base Ply: Polystick MTS or Poly ck MTS PLUS, self -adhered
Undedaymem: Polystick TU P, Polystick TU Plus, Polystick TU Max, Polyflex SAP, Polyflex SAP FR, Mule -Hide SA-APP Cap Sheet and
Mule -Hide SA-APP Cap Sheet (FR), selfadhered.
#27 Maximum Design Pressure =-3201tsF.
Deck. Min. 35/32-inch plywood to meet project requirementsto satisfaction of Authority Havinglurisdiction.
Base Sheet: Elastobase (sanded top surface for hot -asphalt or tomb -applied cap or poly -film surface fortorch-applied cap)
Fasteners OMG #12 Standard Roofgrip or OMG #14 Heavy Duty with OMG 3" Round Metal Plates or OMG Hat Bottom Metal
Plates
Spacing: 64nch o.c. at the 4-inch wide side laps and 6-inch mc. at five (5) equally spaced staggered center now.
Underlaymerlt: Elastoflex G TU or Elastoflex 56 G, applied In full mopping of hat asphalt or Polyflex G, torchapplled.
#28 Maximum Design Pressure=-120 Bsf:
Deck Min. 15/32-inch plywood to meet project requitememsto satisfaction of Authority Having.lurisdiction.
Base Sheet: Elastobase (sanded top surface)
Fasteners: Trofast#12 DP orTrufast#34 HD with Trufast 3" Metal Insulation Plates
Spacing. &Inch o.c. at the 4-Inch wide side laps and 6-inch o.c at five (5) equally spaced staggered center rows.
Underlaymetm Elastoflex G TU or Elastaflex S6 G, applied In full mopping ofhot asphalt.
5.6.4.1 All other direct -deck, adhered Polyglass underlayment systems beneath foam -an the systems carry a Maximum
Design Pressure of-45 psf.
MEMO ETC, U.C. Evaluadan Report P12060.0209-R24
Oylmk9fpurhw&WM#324ss 6TMEDITION (2027)FBCNON-HVHZEVALUATION F1.'u9-R78
Polyglass Roof Underlayments, (954) 233d2a0 'Revision 24: M/24/2018
Page 10 of 24
ONEMOjetc.
5.6.4.2—For- mechanically attachedBaseSheet, the maximum design pressure for the selected assembly shall -meet or exceed
that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design
pressure determined In accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density
designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 217. Assemblies marked
with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January
2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Elastobase, Elastobase P, Polyglass G2 Base or Polygiass APP Base shall not be left exposed for longer than 30-days
after installation.
Polystick IR-Xe or Polystick MU-X shall not be left exposed for longer than 90-days after Installation.
Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Dual Pro, Tile Pro or Elastaflex G TU shall not be left exposed for
longer than 180-days after installation.
Polyflex SAP or SAP FR, or Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR) does not have an exposure
limitation, unless the prepared roof covering is to be adhesive -set tile, in which case the maximum exposure Is 30
days.
Elastoflex S6 G or Elastoflex S6 G FR or Polyflex G or Polyflex G FR does not have an exposure limitation, unless the
prepared roof covering is to be adhesive -set tile (Elastaflex 56 G or Polyflex G only), in which case the maximum
exposure is 180 days.
5.8 Polystick MU-X has been found through comparative testing to have a lesser coefficient of friction than ASTM D226
roofing felt in a dry condition, tested at standard laboratory conditions. Agreement between purchaser and seller, as
set forth in Section 4.3, Note 1 of ASTM D1970-15, should be established as to slip resistance.
5.9 Tile Slippage Limitations (FRSA/TRI April 2012 (04-1211:
When loading roof tiles on the underlayment In direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
,.� •`'(ABF�iZ::T1ESePRAGFirJMRAileNSFoR�UIR��yL�DEfKi, 7�Le�NSPi�,,110N9. •;,<e'..s�.•. ,
Undedaymerltrt
Tile Profile
Staging Method
Maximum Slope
Elastaflex G TU
Flat
10-tile stack
7:12
Lugged
8-tile stack(6 over 2)
6:12
ElastoflexS5 G or S6 G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polystick NM or MTS PLUS
Rat
6-tile stack (4 over 2)
5:12
Lugged
6-tile stack (4 over 2)
4:12
PolystirkTile Pro
Flat or Lugged
&tile stack (4 over 2)
7:12
PolystickTU Max
Flat
6-tile stack (4 over 2) or 10-tile stack
7:12
Lugged
6-tile stack (4 over 2)
7:22
Lugged
10the stack
6:12
PolystickTU P
Flat
&tile stack (4 over 2)
6:22
Lugged
6-tile stack (4 over 2)
4:12
PolystlrkTU Plus
Flat or Lugged
6-tile stack (4 over 2)
7.22
Flat or Lugged
10-tile stack
6:12
Polyflex G or G FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
Polyflex SA P or SA P FR
Flat or Lugged
6-tile stack (4 over 2)
4:12
NEMO ETC, LLC- Evaluation Report P12060.02.09-1124
avGrimle ofAVthW&"n M455 6'e EDITION(2017) FBC NON-HVHZ EVALUATION F1.5259-1128
PoWy = hoof Underlayments(954) 233-2230 Revision 24:OVM/2018
Page 11 of 14
6. —INSTALLATION:— - - - - - - - --- - -
6.1 Polyglass Roof Underlayments shall be installed in accordance with Polyglass published installation requirements
subject to the Umitadons set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove
any dust and debris prior to application, and prime the substrate (if applicable).
6.3 . tla9tpRase,;�Elastdba'se?�giFYfnle=fiiite:NatlHasee .: :^;,:��;_ss::�:: '
6.3.1 Non -Tile Applications:
Shall be installed in compliance with the codified requirements for ASTM D226, Type 11 underlayment in FBC Table
1507.L1 for the type of prepared roof covering to be installed.
Elastobase, Elastobase P or Mule -Hide Nag Base may be covered with a layer of Polystick Polyflex SAP, Polyflex SA
P FR, Mule -Hide SA-APP Cap Sheet or SA-APP Cap Sheet (FR), self -adhered, Elastoflex G TU, ElasOoflex S6 G or
Elastoflex S6 G FR in hot asphalt or Polyflex G or Polyflex G FIRtorch applied. Roof cover limitations are those are
those associated with the top -layer underlayment, as set forth in Table 1,
6.3.2 The Applications:
Eastobase, Elastobase P or Mule -tilde Nail Base are limited to use as a mechanically attached base sheet in the "Two
Ply System" from FRSA/TRI April 2012 (04-12). Reference Is made to Table 1 and Section 5.6.4 herein, coupled with
FRSA/TRI April 2012 (04-12) Installation Manual.
6A: Polystlilc;NE(•S.IYPEUSsIR'-TU:P.'[tJPI.ij5,.TliMaifi:Diiaitrro�T.fPea?a��rt:NIU?,iEorPp1Y�:�?,:Po.�?.�e^
Mule-tlidekg- PPEap'$'1(eetnrB)(ulrAfdeSA-i►PRCap;Sli>;et3F�tY�_
6.4.1 Shall be installed In compliance with the codified requirements for ASTM 03970 (except PolystickTU P) underlayment
6.42
In FBC Table 1507.L1forthe type of prepared roof covering to be installed.
Direct -to -Deck with Mechanically Fastened Roof Covers:
All self -adhering materials, with the exception of Polystick TU Plus, PoWex SAP or SAP FR and Mule -Hide SA-APP
Cap Sheet or SA-APP Cap Sheet (FR) should be bade -nailed in selvage edge seam In accordance with Polyglass / Mule -
Hide back nailing guidelines. Nails shall be corrosion resistant, 11 gauge ring -shank type with a minimum 1-Inch
diameter metal disk or Simplex -type metal cap nail, at a minimum rate of 12" o.c. Polystick TU Plusshould be back -
nailed using the above noted fasteners and spacing, In area marked "nail area, area pare clever" on the face of
membrane. The head lap membrane is to cover the area being back -nailed.
All seal -lap seams (selvage laps) must be
firmly rolled with a minimum 28 lb. hand
roller to ensure full contact and adhesion.
For Dual Pro and Tile Pro, align the edge of
the top sheet to the end of the glue pattern
(the sheet will overlap the fabric). LM
View or Ovelap Seam at oval Pro and Tile Pm
All aver -fabric and over -granule end-laps.shall have a 6-Inch wide, uniform layer of Polyplus 50 Premium Modified
Wet/Dry Cement or Polyglass PGSW Modified Cement applied in between the application of the lap.
Polystick TU Plus, Dual Pro and Tile Pro may not be used in any exposed application such as crickets, exposed valleys,
or exposed roof to wall details
NEMO Em ur Ewluatlon Report P12050.02.0.9-R24
mroOnve QFAUlt"adcn 032455 a EDMON f2017) F8CNON4ttMQEVAWATION FL959-R2a
Pulyjllass Roof underlaymern; (954) 233-IM Revision 24. 01/24/201R
Page 12 of 14
ONEMO I etc.
---Repair-of-Polystick- membranes -isto be accomplished by applying Polyplus-50- Premium -Mbd-fled Wet/Dry Cement or-- - - - - -
Polyglass PG500 Modified Cement to the area in need of repair, followed by a minimum 6 x 6 inch patch of the
Polystick material of like kind, set and hand rolled In place over the repair area. Patch laps, if needed, shall be
Installed Ina water shedding manner.
Al Polystick membranes shall be installed to ensure full contact with approved substrates. Polygiass requires a
minimum of 40-ib weighted -roller or, on. steep slopes, use of a stiff broom with approximately 404bs of load applied
for the field membrane. Hand rollers are acceptable for rolling of patches, laps (min. 28lb roller) or small areas of the
roof that are not accessible to a large roller or broom.
6.4.3 Tile Any I Ications (not allowed forPolvstlek Dual Pro, IR-Xe or Polystick MU-X):
Reference is made to FRSA%TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base
Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table L
For adh esive-set til a applications, refer to Section 5.6.4 herein.
ISAA Two (2) Ply Underlayment Systems:
Polystick MTS or MTS PLUS followed by Polystick MTS, MTS PLUS, TU P, TU Plus, TU Max, Tile Pro, MU-X or Polyflex
SAP is allowable for use under mechanically attached prepared roof systems. Umits of use are those associated with
the top -layer material. This is not a requirement, but is allowable if a 2-ply underlayment system is desired.
Polystick MTS or MTS PLUS followed by Polystick TU P, TU Plus, TU Max, Tile Pro or Polyflex SAP is allowable for use
under foam -on tile systems. UmM of use are those associated with the top -layer material. This is not requirement,
but is allowable if a 2-ply underlayment system is desired.
6.5.1 Elasto0ex G.TU, Elastoflex S6 G orElastoflex S6 G FR shall be installed In compliance with current Polygiass published
Installation . requirements. For use In file applications:
✓ Elastoflex G TU is for use as an alternate to "Mineral Surface Roil Roofing" (ASTM 06380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied `Cap Sheet' in the "Two Ply system" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened or
adhered tile roof systems.
✓ Eiastoflex S6 G is for use as an alternate to "Mineral Surface Roll Roofing" (ASTM D6380, Gass M) In the "Single Ply
System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet' In the'two Ply System" from FRSA/TRI April 2012 (04-121 beneath mechanically fastened or
adhered tile roof systems.
✓ Elastofiex 56 G FR is for use as an alternate to'Minerat Surface Roll Roofing" (ASTM D6380, Class M) in the "Single
Ply System" from FRSA/TRI April 2012 (04-12) beneath mechanically fastened tile roof systems or the Hot Asphalt
applied "Cap Sheet" in the "Two Ply System" from FRSA/YRI April 2012 (04-22) beneath mechanically fastened tile
roof systems.
6.5.2 For hot-asphaltapplications„Elastofim G TU, MastollexS6 G or ElastoflexS6 G FR shall be fully asphalt -applied to the
substrates noted in Section 5.6. Side laps shall be minimum 3-inch and end -laps minimum 6-Inch wide, off -set
minimum 3 feet from course to course. Side and end laps shall be fully adhered in a complete mopping of hot asphalt
with asphalt extending approximately 3/8-inch beyond the lap edge.
PoWex G or Polyflex G FR shall be installed in compliance with current Polygiass published Installation requirements.
For use in tile applications:
✓ Polyflex G is for use as an alternate to the Heat Applied "Cap Sheet" in the 'two Ply System" from FRSA/TRI April
2012 (04-12) beneath mechanically fastened or adhered file roof systems (Base Sheet Umited per 5.6.3).
✓ Polyflex G FR is for use as an alternate to the Heat Applied "Cap Sheet' In the 'Two Ply System" from FRSA/TRI
April 2012 (04-22) beneath mechanically fastened tile roof systems (Base Sheet Limited per 5.6.3).
NEW ETC, LLC. Evaluation Report P12060.02.09.1124
rertlf3mle ofpuMor6ofbn C32Q.:5 EDITION 12017) ESC NON-RVH2 EVALUATION unM-R28
Polyghss Roof Undedaymenrts, ISS4) 233-2230 Revision 24:01/2412018
Page 13 of 14
ONEMOjetc.
-6.6.2 Polyflex G or Polyflex G-FR shall be fully torch -applied tothesubstrates noted in Section 5.6. Side laps shall -be.
minimum 34nch and end -laps minimum 6-Inch wide, off -set minimum 3 feet from course to course. Side and end
laps shall be fully heat -welded and inspected to ensure minimum 3/8-inch flow of modified compound beyond the lap
edge
6.7 riileStagine:
6.7.1 Tile shall be loaded and staged In a manner that prevents tile slippage and/or damage to the underiayment. Refer to
Table 2 herein, and Polyglass published requirements for file staging.
6.7.2 Battens and/or Counter -battens, as required by the file manufacturer and FRSA/TRI April 2032 (04-12) must be used
on all roof slopes greater than 7:12. Precautions should be taken as needed, such as the use of battens or sail-
boards, to prevent tile sliding and/or damage to the underlayment during the loading process.
6.7.3 Polyglass specifies the minimum cure time after Installation of selfadhering membranes and before loading of
roofing tiles is forty-eight (48) hours.
7. BUILDING PERMIT REQuiREMENTs:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the Installation of this product.
8. MANUFAcruiuNG PLANTS:
Contact the noted CIA agency for information on product locations covered for F.A.C. 61620-3 QA requirements. The following
plants have qualified products under their respective physical properties specifications.
PIaM`..'
SPecifieatioir� r ' `*' <cct" �
!Prd'ducf s •;
Fernley, NV, Hazleton, PA & WIMer Haven, FL
ASTM D1970
Polystick MU-X
Hazleton, PA
M-D13-0004.
Elastoflex G TU
Hazleton, PA & Winter Haven, FL
ASTM D1970
Polystick IR-Xe
ASTM D1970 & FRSA/TRI April 2012
PolystickTU Plus
ASTM D1970 & FRSA/TRI April 2012
PolystickTU Max
Tuscaloosa, AL
ASTM D4601, Type 11
Polyglass G2 Base
Winter Hawn, FL
ASTM D226 (physicals)
Elastobase, Elastobase P
ASTM D6SD9
Polyglass APP Base
FRSA/TRI April 2012
Polystick MTS, Polysdck MIS PLUS
FRSA/TRI April 2012
Polystick TU P
FRSA/TRI April 2012
Polyflex: SAP, Polyflex SAP FR
ASTM 03970
Pot stick Dual Pro
ASTM D1970 & FRSA/TRI April 2022
PolvstickTile Pro
ASTM D6264
Elastofiex S6, Elastoflex 56 G FR
ASTM D6222
PolyflexG, PolyflexG FR -
9. QUALITY ASSURANCE ENTITY:
UL, LLC— QUA9625; (314) 578-3405; k.chancellor@us.ul.com
- END OF EVALUATION REPORT -
NEMO ETC. U.C. Evaluation Report P32060.0209-R24
[erttjhotee)Autharkation k32455 6TM EDMON (ZM7) FBC NON-HVHZEVAWATI ON FL5259-RZB
Polyglass Roof Underiaymlants; (954) 233-MO Revision 24; 01/24/201a
Page 14 of 14