HomeMy WebLinkAboutLETTER FROM ARCHITECTONICArchitectonic Inc March 22, 2019 Saint Lucie County Building Department Attn: Roof Permit Plan Review SCANNED 2300 Virginia Avenue B� Ft. Pierce, FL 34982 St. Lucie County Re: Roofing specification prepared for the St. Lucie County Building Dept. for the structure located at 127 Queen Christina Ct., Saint Lucie County, Florida Manufacturer: Extreme Metal Fabricators, LLC Profiles: 1" Nail Strip 26 ga. Steel Roof Panel, FL# 17022.5 Code: FBC 2017; Section R 1507.4.2 Wind Speed: 165 MPH; Ultimate Design Wind Speeds Exposure: C Mean Roof Height: 30' Maximum Pitch: 5/12 Minimum Required Design Pressure: Zone1: 30.9 Zone 2: -51.5 Zone 3: -77.3 Maximum Uplift Pressure: -86 @ 6" o.c. Fastener Spacing & Row Spacing 16" o.c. Fasteners: #10 x 1" Pancake Head Wood Screw (or of sufficient length to meet 3/16" min. penetration through deck Underlayment: Polygiass Underlayment, FL# 5959-R28(self-adhering) Roof Decking: Existing 5/8" plywood sheathing to be nailed w/8d x 2" ring shank @ 6" O.C. thru out zone 1, 4" O.C. perimeter, and 6" O.C. field zone 2, and 4" O.C. thru out zone 3. The above approved, as per Florida Building Code Compliance acceptances, 2017 Florida Building Code, and the Manufacturer's recommendations. 806 Delaware Avenue Fort Pierce, Florida 34950 Tel: 772 460 7751 Fax: 772 460 4244 FILE COPti I www.architectonicinc.com FL Reg #AA26003348 1 of 1