HomeMy WebLinkAboutPRODUCT APPROVAL - NAILSTRIP2160 SW Poma Drive
N, . BY Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product:1" Nailstrip 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or
Wood Deck w/ 0.42 specific gravity with 16" Coverage (Max.)
Rib Height 1"
FILE Cop
7Qm�
��
19b3.otQ(n%
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1: #10 x 1" (min.) Pancake Head Wood Screw to penetrate 3/16" (min.) thru
bottom of support.
Adhesive/Sealant : Bostik 91S' Chem -Chalk one component, polyurethane adhesive with
3/16" continuous bead application along base of male rib vertical flange at each panel
seam.
Underlayment: To be compliant with FBC Sec 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
Install Details: Table A Allowable Loads
METHOD i 1 METHOD 2
DESIGN PRESSURE*
-96 PSF Main field -97.25 PSF Perimeter
FASTENER SPACING
...... -- -
6" O.C. 6" O.C.
_......
SEAM ADHESIVE
Not required 3/16" continuous bead
..-.(seedetails
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & UL 1897-04 TEST REPORT D8133.01-450-18 06/30/15 Specimen #1 & #2
i EQUIVALENCY., UL1897-04 is equivalent to Test Standard UL1897-12. *DesAgn Pressure margin Of safety 2:1
Certificate of Independence:
Locke Bowden, P.E. does not have, not will acquire a
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or contr
report.
•� STATE OF
c .
manufacturing or distributing products
or distributing products under this
sea[
Limitations:
1. Undedayment to be compliance with current Florida Building Code (FBC)2017 61hed..
2. Minimum slope to be compliant with Florida Building Code 2017 61, ad., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for"project specific approval by local authorities wfjurisdiction is allowed by other registered engineers.
5 _Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6t, ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural
Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
FL 17022.5 1.0 Nail Strip (26GA Steel), 16" Wide Roof Panel - Details
16,
Panel Profile
16" O.C.
Deck:
-15i32" or greater Plywood, or
- Vlbod plank
Snap Lock
For h'ETHOD 2:
Apply 3116" Bead Bostik 915TM Sealant
Continuous Along Male Rib Vertical Flange
Fastener
#10 x 1" Min. per Table "A'
Pancake Head Wood Screw
(Typical Fastening Pattern Across Width)
1"
FL 17022.6 1.0 Nail Strip (26GA Steel),16" Wide Roof Panel - Details
-15/32" or greater Plywood, or
-Wood plank
Isometric View
Apply jW Bead Bostik 915T- Sealant
Continuous Along Male Rib Vertical Flange
(Refer to Table "A")