Loading...
HomeMy WebLinkAboutCERTIFICATION - DESIGN LOAD COMPLIANCEPlanning & Development Services DepartmentEMAY Building & Code Regulations Division 2300 Virginia Avenue, Fort Pierce, FL 34982 — (772) 462-19 Certification for Design Load Compliance mitung Project Name: Roof Construction SCANNED Project Address: 2001 N41st Fort Pierce FL St. Lucie Coup Permit#: Occupancy Type: Residential Construction Type: CBS INSTRUCTIONS FOR USE: • This certification must be completed, signed, and sealed by the design professional of record. • Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following: o New Residences (single or multi -family) o Residential Addition o Any accessory structure requiring a building permit o Any non-residential structure. * Note: Form not required for interior renovations provided that no exterior structural elements are affected and certain minor building permits at the discretion of the local building official. Contact the # above for questions. DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that apply) 1. DESIGN CODE: Florida Building Code Fifth Edition with 20 17 Supplements using ASCE 7-10 2. Structure Designed as (check one): X Enclosed _Partially Enclosed _Open 3. Risk Category: _I X II _III _IV Exposure Category: _B X C _D 4. Design Wind Velocity 160 mph _ASO _LRFD End Zone Width: ft 5. Mean Roof Height 8 ft Roof Pitch: 4 :12 Parapet: ft 6. Components & Cladding Design Pressures Used: (PSF, based on 30sgft @ 15'MRH, clearly label on all plan openings): Zone 1: Zone 2: Zone 3: Zone 4: Zone 5: X Garage: 7. Design Loads: Floor: 30 PSF Roof/Dead: 30 PSF Roof/Live: 15 Balcony: PSF Dock: NSA PSF Deck: NIA PSF Stairs: NIA PSF Fence: Nip` PSF Railings: NSA PSF 8. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not: 9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not: 10. Design Soil Bearing Pressure: 2000 PSF Soil Test Reports Submitted? _Yes DESIGN PROFESSIONAL CERTIFICATION STATEMENT: I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie ements depicted on these plans provide adequate resistance to the design Wayne Gandy Print Name PE33134 Cert # & Co. Cert Auth. Designwest Associates 1610 E. Colonial Drive, Ste: 230, Orlando, FI 32803 Company Name & Address