-i FILE COP`
ProdactfAp rova1 SCANNED
j USER: Public User BY
St. Lucie County
fProduct Approval Menu > Rroduct or Application Search > Application List> Application Detail
J
FI # F�L� *7NQR7
Application Type Revision
Code Version 2017 (` l
Application Status Approved
Comments 08/18/2017v. date reapply 08/21/17
Archived
Product Manufacturer Extreme Metal Fabricators, LLC
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
flvalidation@yahoo. com
Authorized Signature Richard McKuhen
flvalidati(L @yahoo.com
Technical Representative Richard McKuhen
Address/Phone/Email 2160 SW Poma Drive
Palm City, FL 34990
(772)872-8034
'cn hard@emfab.net
REVIEWED FOR
Quality Assurance Representative CODE' COMPLIANCE
Address/Phone/Email ST.. LUCIE COUNTY
Category Roofin BOCC
Subcategory Metal Roofing _
Compliance Method Evaluation Report from a Florida Registered Architect or a
Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who LOCKE BOWDEN
developed the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
https://mail-attachment.googieusercontent.com/attachmentlu/0l?ui=2&ik=5cb9sbI f25&attid=0.1 &permmsgid=msg-f:1622108072669994827&th=1682... 1/5
111012019 https://mail-attachment.googleusercontent.com/attachment/u/0/?ui=2&ik=5cb96blf25&atfid=0.l&pennmsgid=msg-f:16221080726699948...
s Validation Cher Hardcopy Received
Certificate of Independence
FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf
Referenced Standard and Year (of Standard) Standard
TAS 125
UL 1897
-UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method I Option D
08/18/2017
08/25/2017
08/28/2017
10/10/2017
Year
2003
2012
2006
FL #
Model, Number or Name
Description
17022.1
1 - "5V Crimp" (R6)
26 Gauge steel, 3/8" rib height, 24" wide lapped
roof panel mechanically attached to 15/32"
plywood or Wood Deck with fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 1I FL 17022.1 5 V CRIMP ssr.pdf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions.
FL_17022 R7 AE FL 17022.1 5 V
Install the assembly in compliance with the
CRIMPdsscp_df
installation method listed in this report and
Created by Independent Third Party: Yes
applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.2
2 - "5V Crimp" (R6)
0.032" Aluminum, 3/8" Rib height, 21" wide
lapped roof panel, mechanically attached to 15/32"
plywood or Wood Deck with exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022_R7 IT FL 17022.2 5 V CRIMP 0.032
A UM , srRdf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for
Evaluation Reports
conditions.Install the assembly in compliance with
FL17022 R7 AE FL 17022.2 5 V CRIMP 0,032
L ssrpdf
the installation method listed in this report and
applicable code sections of FBC. Refer to
Created by Independent Third Party: Yes
manufacturer's installation instructions.
https:llmail-attachment.googleusercontent.com/attachmentfu/0/?ui=2&ik=5cbg6bl f25&att1d=0.1 &permmsgid=msg4:1622108072669994827&th=1682... 2/5
1/1U/2U79 https://mail-attachment.googleusercontent.com/affachmenttu/0/7ui=2&ik=5cb96b1 f25&attid=o.1&pennmsgid=msg-f:16221080726699948...
17022.3 3 - "1.5" Mechanical Seam"
i(R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report -for conditions
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions.
17022.4 4 - "l.5" Mechanical Seam"
(R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions.
17022.5 15 - "I in. Nail Strip" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions.
17022.6 16 - "1 in. Nail Strip" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions.
17022.7 17 - "l.5 in. Nail Strip" (115)
1.5" rib ht 16" wide, 24 gauge steel, standing
seam roof'pmial mechanically attached to 15/32"
plywood or wood deck with clips and fasteners.
Installation Instructions
FL17022_R7 II FL 17022.3 1.5 MECHANICAL
seam 24ga_ssnpdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Created by Independent Third Party: Yes
1.5" rib height, 16" wide, 0.032" aluminum,
standing seam roof panel mechanically attached to
15/32" plywood or Wood Deck with clips and
fasteners.
Installation Instructions
FL17022 R7 TT FL 17022 4 MECHAN TAL
SEAMALUMTNUM ¢srQdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7 AE FL 17022.4-MECHANCIAL
SEAM ALUMINUM_ssr.pdf
Created by Independent Third Party: Yes
1" rib height, 16" wide, 26 gauge steel, standing
seam roof panel mechanically attached to 15/32"
plywood or wood deck with fasteners.
Installation Instructions
FL17 22 R7 11 FL 17022.5 1.0
NAILSTRIP ssnpdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7 AE FL 17022.5 1.0
NATLSTRTP ssrpddf
Created by Independent Third Party: Yes
1" rib height, 16" wide, 0.032" aluminum, standing
seam roof panel mechanically attached to attached
to 15/32" plywood or Wood Deck with fasteners,
Installation Instructions
FL17022 R7JI FL 17022.6 1.0 NAIL
STRIP 0 032 ALUM ssr pdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7AF FL 17022.6 1.0 WATT
STRIP 0.032 ALL>M.,acrpdf
Created by Independent Third Party: Yes
1.5" rib height, 19" wide, 26 gauge steel, standing
seam roof panel mechanically attached to 15/32"
https:Hmail-attachment.googieusercontent.com/attachment/u/0/?ul=2&ik=5cbg6bif25&attid=o.l &permmsg1d=msg-f:1622108072669994827&th=1682... 3/5
1/10/2019 https://mail-attachment.googiousercontent.com/attachment/u/0/?ui=2&ik=5cb96b1f25&attid=0.1&permmsgid=msg-f,.16221080726699948...
plywood c od deck with fasteners.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions
and limitations of use. Install the assembly in
compliance with -the installation -method listed -in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions.
17022.8 18 - "EMAX Rib" (115)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions.
17022.9 19 - " PBR MAX" (R5)
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: No
Design Pressure: +N/A/ -Table A
Other: Refer to evaluation report for conditions
and limitations of use. Install the assembly in
compliance with the installation method listed in
this report and applicable code sections of FBC.
Refer to manufacturer's installation instructions.
Installation Instructions
FL17022 R7 ii=FL 17022.71.5 Nail Strip
6GA ssnpdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022_R7 AE FL 17022.7 1.5 Nail Strip
69ssnpdf - - -
Created by Independent Third Party: Yes
29 gauge steel, lapped roof panel mechanically
attached to 15/32" plywood or wood deck with
exposed fasteners.
Installation Instructions
FL17022 R7 II FL 177022.8 EMAX Rib ssnpdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FL17022 R7AE FL 177022.8 EMAX
Ri ssnpdf
Created by independent Third Party: Yes
26 gauge steel, lapped roof panel mechanically
attached to 15/32" plywood or wood deck with
exposed fasteners.
Installation Instructions
FL17022 R7 II FL 17022.9 PBR RIB ssnpdf
Verified By: Locke Bowden, P.E. 49704
Created by Independent Third Party: Yes
Evaluation Reports
FLI7022 R7 AE FL 17022.9 PBR RIB ssnpdf
Created by Independent Third Party: Yes
Back Next
Contact Us:: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Copysjght 2007-2013 State of Florida.:: Rrivacy Statement
Accessibility Statement:: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in
response to a public -records request, do not send electronic mail to this entity. Instead, contact the office by
phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must
provide the Department with an email address if they have one. The emails provided may be used for
official communication with the licensee. However email addresses are public record. If you do not wish to
supply a personal address, please provide the Department with an email address which can be made
available to the public. To determine if you are a licensee under Chapter 455, F.S., please click here.
Product Approval Accepts:
,,
1 1 MI�� i�,I
https://mail-attachment.googieusercontent.com/attachmentlu/0/?ui=2&ik=5cb96bl f25&attid=0.1 &permmsg1d=msg-f:1622108072669994827&th=1682... 4/5
Palm City, FL 34990
Compliant with Florida Building Code 2017 (611 ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec.1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec.1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD i
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE"
-86 PSF
93.5 PSF
-301 PSF
-228 PSF
ROW SPACING
16" o.c.
16" o.c.
8" O.C.
6" Q.C.
FASTENER SPACING (ALONG Panel width)
12" o.c.
12" o.c.
12" o.c.
12" o.c.
FASTENER SIZE
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580.06 & 1897-042 Test Report Db893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/is
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897--04 is equivalent to test standard UL 1897--1� *Design
nrnrUy
pressure margin of safety 2.1
,111
Locke Bowden, P.E. does not have, not will acquire a financial in \t4.4� n e j�"cq n4 m iyfacturing or distributing products
under this evaluation. v• ;.•'
Locke Bowden, P.E. is not owned, operated, or controlled by atly compart$pm49afaLturem, or distributing products under this
report. •
! y✓Cr
Ti
�'t'r
FL17022.1 5 rimp (26GA Steel), 24" Wide Roc anel - Details
Limitations: '
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6th ed.
2. Minimum slope to be compliant with Florida Building Code 2017 61h ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6th ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
— Fasteners -
#9.1-12"Mln. or
#10.1-1Q"Min. per7eb/e'q"for Row bV Crimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Screws
Deck:
-15132' a greater Plywood, or
- Whod plank
Panel Profile
12"
D.C. I — D.C.
Fasten 1
9 x 1-1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex Wisher Head Screw
Panel Spaced 12" o.c. across the Panel VVdth
OverlapReferto Table "A" for SpacingAlong Panel
Length
Deck-15/32" or greater
Plywood, or
-Mod plank