Loading...
HomeMy WebLinkAboutBOAT LIFTCenter Line 8 8— R B A Q �hllXf I\ N GUIDE POLE F I—\ F D 0 4• 7 C� Mean High Tide — — 10 WELD E J Mean Low Tle— Existing Berm (Depth Varies) ----------- K 24" Min. Embedment Typical Section @ Seawall Scale: 3/, = 1=0" Mph 4 1%\% F G 6' (Typical Can Vary) 65'-90' 1 M L Exist. Seawall To Remain RECeVED APR 01 2018 Permit"' e St muna o®partm,t de �O"nty oinless steel threaded rods IY 150 or approved equal), embedment set in epoxy SCANNED BY Geuerol Notes: St. LUcl COUr • Design in accordance with Florida Building Code, 6th Edition (2017). • This lifting structure has been designed to withstand wind loads associated with speeds of V (ult) = 180 MPH, (3 Second Gust) Exposure 'D' without a boat on the lift per ASCE 7-10 using above ground sign1wall method. The lifting structure including boot has been designed to withstand wind speeds of V (ult) = 73 MPH in Exposure 'D'. • Boats shall not be stored on lift during high wind events. • Do not scale drawings for dimensions. • Licensed Contractor to verify location of existing utilities prior to commencing work. • The Licensed contractor to install and remove all shorin} and bracing as required for the proper installation of the work. • Licensed Contractor to obtain all permits as necessary from all Local, State, and Federal agencies. • Aluminum: Material 6061 T6 Aluminum, all welds are min. 4" full fillet weld using 5556 filler alloy, all welding must conform to AISC steel construction manual 14th ED as inspected and verified by pthers. The contractor is responsible to insulate aluminum members from dissimilar metals to prevent electrolysis. • Aluminum members in contact with concrete and wood shall be protected by "Koppers Bituminous Paint" or Polyethylene Tape UHMW (ultra high molecular weight). 11.7 mils (0.30 mm) min. total thickness in accordance with current Florida Building Code. • All anchors to be Hilti Brand or Approved Equal. All bolts shall be hot dipped galvanized or stainless steel & meet the requirements of ASTM A304 with hardened washers and hex nuts. Washers shall be used between wood & bolt head & between wood &.nut. Where generic fasteners are labeled in details, capacities shall be equal to or greater than Hilti Kwik Bolt II or Red Head thru bolts SAE Grade 5 or better. Embedment depths specified herein are depths into solid substrate and do not included thickness of other finishes. , MW Engineering has no control of the manufacturing, performance or installation of this product. These generic plans were engineered in accordance with accepted engineering practices and data provided by the manufacturer. • Piles shall be driven to refusal and sufficiently penetrated into sand or rock strata to support lift capacity, weight and loads. • Each pile to carry commensurate load LE. 114th lift capacity for 4—post lift (Factor of Safety of 1.5) • 1,11owoble minimum compression pile capacity of 5 tons. • The contractor of record shall verify pile type, installation ead o ' i o010 CWC%with FBC 6th ED (2017) • Sub —surface conditions can vary greatly. � � REVIEWED FOR FCODE COMPLIANCE 4;'r L 1 AP`IC r%r%l fir's as DATE NOTES REVISIONS NOT VALID UNLESS SIGNED WITH ORIGINAL ENGINEER'S SIGNATURE AND rSEDEMBOSSEDSEAL MW ENGINEERING INC 902 NE 1 Street Suite #2 Pompano Beach, Florida 33060 Ofc: 754-333-0877 W W W. MwEngineering, net Proposed Elevators 5,000 lb to 24 000 lb NEPTUNE BOAT LIFTS 228 SW 21 Terrace Fort Lauderdale, Florida 33312 Phone: 954-524-3616 Fax: 954-524-3604 A I 32 0110712018 Changed FBC Note 9ATE 05.12.2015 DRAWN BY: WRT CHECKED BY. WM MARK E. WEBER, P.E. — LICENSE #538951 CA 30702 JOB NO: M.tar 3q.dx q Sheet 1 of 3 i E C E E F C.7 H r J K L M N O P Q R Components ift Capacity (In Pounds) 5,000 7,000 10,000 12,000 14,000 15,000 17,000 20,00( 24,000 t.(2 arriage Boom Requiredper Lift Arm) AS C 6"x3.6 AS C 8"x4.3 - AS C 10"x5.3 AS C 12"x7.4 Cradle Arm AA I - 6"x4.7 AA 18"x7.1 AA 110"x8.7 AA 170'k10.286 AA 112"x11.7 AA 112"x14.3 usset Plate ired per Lift Arm) a"'XY Flat Bar lLowerGuide }"x4" Flat Bar j'X5" Flat Bar }"x6" Flat Bar"x8"Flat Bar Carriage Angleired per Lift Arm) Z')Q x3" Angle s"x3'k4"Angle s"x4"x6"Angle Carriage Angleired per Lift Arm) �"x2'k3" Angle J"x3'k4"Angle"x4"x6"Angle ulley Plateired per Lift Arm) �'k6" Flat Bar }"x6" Flat Bar }'k6" Flat Bar }"x8" Flat Bar r Guide Wheelired per Lift Arm) 4"Diameter 5'SQ"x"I.D.6" Diameter r Guide Wheel (1 Required per Lift Arm) 4"Diameter 4"x5-3/4"x 11/8"ID 6" Diameter Cable Size (Stainless Steel) 7" Diameter 7x19 SS 304 J" Diameter 7x19 SS 304 Guide Track AA I - 6"x4.7 AA I - 8"x6.3 AA I - 8"x7.1 AA I - 10"x8.7 AA I-10"x10.286 AA 112"x11.7 AA 112"x14.3 Guide Track To Guide l rack Brace AA CS 4"x1.8 AA CS 5"x2.2 AA CS 6"x2.8 Attachment (2) J'xZx3" Angl with welded Bracket t with welded z" (2) "x3"xhick Thick Inner Plate Inner Plate Inneglesr Thick Inner Plate welded'" Thick Inner Plate eldee'k Thick Track Mount Connector (2 Required per Lift Arm) j'k2"x4"Angle8 "Bolts j'x3"x4"Angle &t"Bolts }"x3"x6"Angle 8t"Bolts Motor Size (Horse PowerNoltage) Guide Post Socket 2" Diameter Schedule 80 Pipe 3" Diameter Schedule 80 Pipe Bunk Bracket Support (2 Each Side of Lift Arm) T x2"x2" Bunk Boards " " 3x8Pressure Treated 3"x10" Pressure Treated Southern Yellow Pine #1 Southern Yellow Pine #1 B a a B B— C Dimensions ft Capacity Lin (IPounds) 5,000 7,000 10,000 12,000 14,000 15,000 17,000 20.000 24,000 1 10, 10, 10, 10, 10, 10, 10, 10, 10, 2 7' 7' 8' 8' 8' 8' 10, 10, 10, 3 6" 6" 6" 6" 6" 6" 6" 6" 6" .Y 4 6' 6' 6' 6' 6' 6' 6' 6' 6' `m 5 1,_6" 1'-6" 1,_6" 1'-6" V-6" 1'-6" 1'-6" V-6" 1'-U" 0 N `m E_ 6 2'-8" 2'-8" 2'-8" 2'-11" 2'-11" 2'-11" 3'-3" 3'-3" 3'-3" 6 7 4' 4' 4'-6" 5' 5' 5' 6' 6' 6' 8 P_6" 1'-6" 1'-6" 1'-6" V-6" V-6" V-6" T_6" 1'-6" 9 13" 13" 13" 13" 13" 13" 13" 13" 13' 10 81. 1 87 1 a" a" I a• a- 87 11 9" 10" 3 DATE NOTES REVISIONS NOT VALID UNLESS SIGNED WITH ORIGIFL ENGINEER'S SIGNATURE AN RAISED MBOSSED SEAL MW ENGINEERING INC 902 NE 1 Street Suite #2 Pompano Beach, Florida 33060 Ofc: 754-333-0877 WWWRwEngineering.net Proposed Elevators p 5,000 lb to 24 000 lb ' NEPTUNE BOAT LIFTS 228 SW 21 Terrace Fort Lauderdale, Florida 33312 Phone: 954-524-3616 Fax: 954-524-3604 ac"i r. 32 Ol/07/2018 Changed FBC Note DAM- 05.12.2015 Ow`x'N BY. WRT CHECKED BY. WM MARK E. WEBER, P.E. LICENSE#538951 CA 30702 JOB No: Elevator 32dw9 Sheet 3 of 3 t