HomeMy WebLinkAboutEVALUATION REPORTL. Roberto Lomas P.E. 233 W. Main St Danville. VA 24541 SCANNED 434-688-0609 13Y r1lomas i<Irlomaspe.cwm St. Lucie County Manufacturer: Eastern Architectural Systems 16341 Domestic Ave. FT Myers. FL 33912 Engineering Evaluation Report Product Line: Series 176 PW Fixed Window 72" x 63" Impact HVHZ Report No.: 513043B Compliance: The above mentioned product has been evaluated for compliance with the requirements of the Florida Department of Business and Professional Regulation for Statewide Acceptance per Rule 61 G20-3.005 method 1(a). The product listed herein complies with requirements of the current Florida Building Code. Supporting Technical Documentation: 1. Approval document: drawing number 08-02294 Revision B, prepared, signed and sealed by Luis Roberto Lomas P.E. 2. Report No.: ESP011976P-1 & 3 signed and sealed by Ramesh C. Patel P.E. Element Materials Technology, Wausau, WI AAMA/VVDMA/CSA 101/I.S.2/A440-05/08/11 Design pressure: ±125.Opsf Water penetration resistance 15.0psf ASTM E1886-05 and ASTM E1996-09 ASTM E1886/ E1996 Large Missile Impact, Level D, Wind Zone 4 ASTM E1886I E1996 Cyclic Load Test, ±80.Opsf design pressure 3. Report No: ESP011976PA D & 3D signed and sealed by Ramesh C. Patel P.E. Element Materials Technology, Wausau, WI TAS 201-94 Large Missile Impact Test, Level D, Wind Zone 4 TAS 202-94 Uniform Static Air Pressure, ±125.Opsf design pressure, water penetration resistance: ±15.Opsf TAS 203-94 Cyclic Pressure loading ±80.Opsf design pressure. 4. Anchor calculations, report number 513043-1, prepared, signed and sealed by Luis Roberto Lomas P.E. Limitations and Conditions of use: Maximum design pressure: ±80.Opsf Maximum unit size: 72" x 63" • Units must be glazed per ASTM El300-04, see installation instructions for glass details. This product is rated to be used in the HVHZ. This product is impact resistant and does not require impact protection in wind borne debris regions. • Frame material to be rigid PVC. Installation: Units must be installed in accordance with approval document, 08-02294 Revision B. Certification of Independence: Please note that I don't have nor will acquire a financial interest in any company manufacturing or distributing the product(s) for which this report is being issued. Also, I don't have nor will acquire a financial interest in any other entity involved in the approval process of the listed product(s). /9x/•00, ST, LUCIE coU,-"rY BUILDLh!C nr,rLS HEVIEWFO BATE O ;hSPEC ION WILL BE CEO\ JOB FOR CODE COMPLIANCE ST. LUCIE COUNTY 1 of 1 BO^VC FILE COPY 0„ (11uj/y `INNJ�9 R L o�9 1,i _=*• 0 51 •*_ TAT OT OF F , �i0�F •.'c� 0 RIOP'G��J� Luis R. Lomas, P.E. FL No.: 62514 04/11/2017 NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH REQUIREMENTS OF THE FLORIDA BUILDING CODE INCLUDING THE HVHZ. 2. WOOD FRAMING AND MASONRY OPENING TO BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO STRUCTURE. FRAMING AND MASONRY OPENING IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 3. IX BUCK OVER MASONRY/CONCRETE IS OPTIONAL. 4. WHERE SHIM OR BUCK THICKNESS IS LESS THAN 1-1/2" WINDOW UNITS MUST BE ANCHORED THROUGH THE FRAME IN ACCORDANCE WITH MANUFACTURERS PUBLISHED INSTALLATION INSTRUCTIONS. ANCHORS SHALL BE SECURELY FASTENED DIRECTLY INTO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE MATERIAL. 5. WHERE WOOD BUCK THICKNESS IS I-1/2" OR GREATER, BUCK SHALL BE SECURELY FASTENED TO MASONRY, CONCRETE OR OTHER STRUCTURAL SUBSTRATE. WINDOW UNITS MAY BE ANCHORED THROUGH FRAME TO SECURED WOOD BUCK IN ACCORDANCE WITH MANUFACTURERS PUBLISHED INSTALLATION INSTRUCTIONS. 6. WHERE 1X BUCK IS NOT USED DISSIMILAR MATERIALS MUST BE SEPARATED WITH APPROVED COATING OR MEMBRANE. SELECTION OF COATING OR MEMBRANE IS THE RESPONSIBILITY OF THE ARCHITECT OR ENGINEER OF RECORD. 7. BUCKS SHALL EXTEND BLYOND WINDOW INTERIOR FACE SO THAT FULL FRAME SUPPORT IS PROVIDED. B. FOR FIN INSALLATION SHIM AS NEEDED. FOR FRAME INSTALLATION SHIM AS REQUIRED AT EACH ANCHOR LOCATION WITH LOAD BEARING SHIM. SHIM WHERE SPACE OF 1/16" OR GREATER OCCURS. MAXIMUM ALLOWABLE SHIM STACK TO BE 1/4". 9. SHIMS SHALL BE LOCATED, APPLIED AND MADE FROM MATERIALS AND THICKNESS CAPABLE - OF SUSTAINING APPLICABLE LOADS. 10. WIND LOAD DURATION FACTOR Cd-1.6 WAS USED FOR WOOD ANCHOR CALCULATIONS. 11. FRAME MATERIAL: EXTRUDED RIGID PVC. 12. UNITS MUST BE GLAZED PER ASTM E1300-04, SEE SHEET 2 FOR GLASS OPTIONS. 13. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED FOR THIS PRODUCT IN WIND BORNE DEBRIS REGIONS. 14. FOR ANCHORING F114 INTO WOOD FRAMING OR 2X BUCK USE w8 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. REMOVED FLUSH INSTAUATMN 07/23/14 R.L. REVISED INSTALLATION DETAILS 06/23/15 R.L. 15. FOR ANCHORING FRAME INTO WOOD FRAMING OR 2X BUCK USE j14 WOOD SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 7/16" MINIMUM EMBEDMENT INTO SUBSTRATE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 16, FOR ANCHORING FRAME INTO MASONRY/CONCRETE USE 3/16" TAPCONS WITH SUFFICIENT LENGTH TO ACHIEVE A 1 1/4" MINIMUM EMBEDMENT INTO SUBSTRATE WITH 2 1/2" MINIMUM EDGE DISTANCE. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 17. FOR ANCHORING FRAME INTO METAL STRUCTURE USE #14 SMS OR SELF DRILLING SCREWS WITH SUFFICIENT LENGTH TO ACHIEVE 3 THREADS MINIMUM BEYOND STRUCTURE INTERIOR WALL. LOCATE ANCHORS AS SHOWN IN ELEVATIONS AND INSTALLATION DETAILS. 18, ALL FASTENERS TO BE CORROSION RESISTANT. 19, INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURERS INSTALLATION INSTRUCTIONS AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BELOW: A. WOOD - MINIMUM SPECIFIC GRAVITY OF G=0.42 B. CONCRETE - MINIMUM COMPRESSIVE STRENGTH OF 3,192 PSI. C. MASONRY - STRENGTH CONFORMANCE TO ASTM C-90, GRADE N, TYPE 1 (OR GREATER). D. METAL STRUCTURE: STEEL 18GA. 33KSI OR ALUMINUM 6063-T5 1/8" THICK MINIMUM 20, GEOMETRIC SHAPES ARE ALSO APPROVED, APPROVED GEOMETRIC SHAPES DIMENSIONS SHALL NOT EXCEED INSCRIBED DIMENSIONS OF APPROVED RECTANGULAR ASSEMBLY SHOWN IN SHEET 2. GEOMETRIC SHAPES ARE NOT LIMITED TO SHAPES SHOWN HEREIN. TABLE OF CONTENTS SHEET NO. 1 DESCRIPTION NOTES ELEVATIONS AND GLAZING DETAIL 3 - 5 1 INSTALLATION SERIES 176 PW FIXED WINDOW IMPACT HVHZ 72" x 63" NOTES NTS 08-02294 SIGNED: 04/11/2017 73 1/4" MAX TIP TO TIP WIDTH 72" MAX O.A. WIDTH — 6" MAX 9 1/2" MAX O.C. 6 MAX 64 I/4" MAP 91/2„ / TO MAX O.C. / TIP 63" MAX O.A. HEIGHT 1 6" MAX SERIES 176 PW FIXED WINDOW FRAME INSTALLATION EXTERIOR VIEW I" 1/8" HS 3/16" HS .090 SENTRYGIAS BY DUPONT Illjlll 1/8" HS EXTERIOR INTERIOR ^.LA21NC QUANEX DURASEAL BEAD SPACER SYSTEM SIKAFLEX 1/2 ! /2" BITE ji 552 SETTING BLOCK GLAZING DETAIL 6" MAX 2" MAX 12" MAX O.C. 63" MAX CA FRAME HEIGHT DESIGNPRESSURERATING IMPACT RATING t60.OPSF LARGE MISSILEIMPACT MISSILE LEVEL D, WINDZONE 4 AND HVHZ PEN90H5 6EV mscxwnoN an: ismavm A REMOVED FLUSH IN6TALIAPON 0]/23/14 R.L. i -REVISED INSTAIJAPON DETNLS O6/2]/15 R.L. — 72" MAX CA FRAME WIDTH 12" MAX —I 2" MAX D.C. SERIES 176 PW FIXED WINDOW FIN INSTALLATION EXTERIOR VIEW SERIES 176 PW FIXED WINDOW IMPACT HVHZ 72" x 63" ELEVATIONS AND GLAZING DETAIL muwx: w.c xo. 6EV J.L. 08-02294 B mu£ NTS Imm 02/23/14 s-2 OF 5 SIGNED: 04/11/2017 •i 5/8" MIN. EDGE DISTANCE WOOD FRAMING METRE OR 2% BUCK 7 7/16" MIN. STRUCTURE BY OTHERS BY OTHERS EMBEDMENT APPROVED :41[n 1/4" MAX. J SEALANT SHIM SPACE APPROVED BEHIND FLANGE SEALANT BEHIND FLANGE #14 WOOD SCREW INTERIOR EXTERIOR EXTERIOR #14 WOOD SCREW APPROVED SEALANT BEHIND FLANGE WOOD FRAMING OR 2X BUCK BY OTHERS 5/8" MIN. _ EDGEDISTANCE SECTi'v_M1I WOOD FRAMING OR 2X BUCK INS7ALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS. NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 APPROVED - SEALANT BEHIND FLANGE 1/4" MAX SHIM SPACE METAL - STRUCTURE BY OTHERS MIN RENT RfK9 1" MIN. - Rfl MCRIPIION DATE WPRw EDGE DISTANCE A REMOVED RUSH INSTAUAPON 07/23/14 R.L. B REVISM INST&L1APON DETAILS 06/23/15 R.L. METAL STRUCTURE 1/4" MAX. SHIM SPACE 1/4" MAX. BY OTHERS SHIM SPACE #14 SMS OR SELF DRILLING Q SCREWS 0 14 SMS OR "� INTERIOR SELF DRILLING 0 SCREW I 1" MIN. EDGE DISTANCE L.1L1 APPROVED EXTERIOR SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL METAL STRUCTURE INSTALLATION INTERIOR 1 7/16" MIN. EMBEDMENT _ 1/4" MAX. SHIM SPACE I` 5MIN. EDGEE DISTANCE Q f ° INTERIOR #SELF 14 SMS OR SCREW DRILLING #74 WOOD UL�� SCREW 1/4" MAX. WOOD FRAMING SHIM iM SPACE OR 2X BUCK BY OTHERS 0 t APPROVED EXTERIOR SEALANT JAMB INSTALLATION DETAIL BEHIND FLANGE WOOD FRAMING OR2X BUCK INSTALLATION 1" MIN. EDGE DISTANCE SIGNED: 04/17/2017 I+ I � P FI6'AL CROSS utrt (ON . � iffaxB _ __ �A �t�a•�,vs^mw—� `�.yXGEMSFgiP: SERIES 176 PW"FIXED WINDOWy IMPACT HVHZ Z: ox-6j61 *' FLANGE INSTALLATION DETAILS �20 •. BTAT OF W� ow.rm: owc xo. 6EV R10?' J.L. WIC 08-�022 49 e �i�/s/pNA11E��p• NTS 02/23/14 3 OF 5 __ _ CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK SEE NOTES 3-7 SHEET 1 APPROVED SEALANT BEHIND FLANGE EXTERIOR APPROVED SEALANT BEHIND FLANGE OPTIONAL 1X BUCK NOTES 3-7 SHEET 1 CONCRETE/MASONRY ERS 2 1/2• MIN. EDGE DISTANCE • n 1 1/4- MIN. <• EMBEDMENT a •: r 1�1/4" MA%. SHIM SPACE INTERIOR 3/I6" TAPCON 3/16" TAPCON 1/4" MAX. SHIM SPACE BY OTH \�. �• w I 1i4 MIN • _ � . o u n. J5 2 1/2" MIN. EDGE DISTANCE VERTICAL CROSS SECTION CONCRET&MASONRY INSTALLATION CONCRETE/MASONRY BY OTHERS OPTIONAL 1X BUCK •° SEE NOTES 3-7 SHEET 1 3/16" TAPCON —� �a �.a 2 1/2" MIN. EDGE DISTANCE REY Om RW IXSCRWR011 aic A%AR'ID A REMOVED FLUSH INSTALLATION 07/23/14 R.L. B REMSEB INSTALLATION DETAILS 06/23/15 1 R.L. 1 1/4" MIN EMBEDMENT /4- MAX. SHIM SPACE INTERIOR �- APPROVED EXTERIOR SEALANT BEHIND FLANGE JAMB INSTALLATION DETAIL CONCRET&MASONRY INSTALLATION NOTES: 1. INTERIOR AND EXTERIOR FINISHES, BY OTHERS, NOT SHOWN FOR CLARITY. 2. PERIMETER AND JOINT SEALANT BY OTHERS TO BE DESIGNED IN ACCORDANCE WITH ASTM E2112 SP �° S SERIES 176 PIN FIXED WINDOW IMPACT HVHZ 72" x 63" FLANGE INSTALLATION DETAILS Iorwwn: MGNO. J_L. 08-02294 '� NTS.__°"F 02/23 14 - 'T 4. OF 5 _ SIGNED: 0411112017 APPROVED SEALANT BEHIND FIN #8 WOOD SCREW 7/16• MIN 7 EDGE DISTANCE EXTERIOR 7/I6" EDGE DIS #8 5 4✓PROVLD —� LillIVAL (ifiV.SJ .+C li 1=1V ! V000 �RA+FlN' OR 2X RNCC INRTAI I ATION 1 1/4" MIN. EMBEDMENT WOOD FRAMING BY OTHERS 1/4" MAX. r SHIM SPACE INTERIOR WOOD FRAMING BY OTHERS 1 1/4- MIN. EMBEDMENT flfY1LON5 REV C6LPoPTON W1F MPflLItO A REMDVED FLUSH INSTALLATION 07/23/14 FI.L B REVISED INSTALLATION DETAILS O6/23/16 R.L —I 1/4" MAX SHIM SPACE INTERIOR HB WOOD �/ SCREW J// u APPROVED SEALANT — EXTERIOA BEHIND FIN 7/I6" MIN EDGE DISTANCE JAMB INSTALLATION DETAIL WOOD FRAMING OR 2X BHCX INSTALLATION 1/4" MAX NOTES: SHIM SPACE I. INTERIOR AND EXTERIOR FINISHES, BYOTHERS. NOTSHOWNFOR CLARITY. 2. PERIMETER AND JOINT SEALANT SYOTHERS TO BE DESIGNED INACCORDANCE WITH ASTM E2112 WOOD _ SIGNED: 04/11/2017 cpnuinlr. pY nTr+vP� _ __ er•r n»so ^ ,•� � � 111111l L lC,41 O.T'i. • .. .. _.. _ ,., .. rj�' �, �,•�.� ' sue• .P :G 176 ?'!I Fi WINOO:lYIMPACT ❑VH'_ �JD„I ••'/+_ �SERIFS 2" FIN INSTALLATION DETAILS 'pp, TAT OF no... REV 400D: 1owc I 08 B /7j7SIONA"E�V�Q NTS °"Ic 02 23 14 mTxT 540E 5 _ �i ( _ Kitchen Renovation/Window Replacement Kitchen Renovation/Window Replacement . New Vinyl • Paint Kitchen • Install Recess Lighting • Kitchen O (see Kitchen Drawing) ' Window W (see Window Drawing) mi 411111111111 LL Window Work To Conform To FBC, 2017 6th Edition Cooke Construction, Inc. Scope of Work Job: Hodges CRenovation Division Kitchen Renovation/Window Replacement CGC1520585 Owner: Hodges Date: March 28, 2019 1276 NE Business Park Place Phone: (772) 530-0659 Address: 4115 S. Indian River Drive Drawn By: Nathan Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Fort Pierce, FL 34982 Sheet #: 1 of 3 New Kitchen Layout Kitchen (same Footprint) • Replace Existing Ceiling Light w/ Recess LED Lights • Replace Existing Light @ Above Sink w/ Recess LED Light • ADD Recess LED Light @ Wine Display • ADD Under Cabinet GFI Outlets per Code • Install New Cabinets & Counter Tops Y®•3 • Plumb Kitchen Sink & Faucet (Same Location) • Repair any Drywall Damage W • Paint Walls & Trim J Work To Conform To FBC, 2017 6th Edition Cooke Construction, Inc. Scope of Work Job: Hodges CRenovation Division New Kitchen Layout CGC1520585 Owner: Hodges Date: March 28, 2019 1276 NE Business Park Place Phone: (772) 530-0659 Address: 4115 S. Indian River Drive Drawn By: Nathan Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Fort Pierce, FL 34982 Sheet #: 2 of 3 Window Replacement Window Replacement (same Footprint) * Replace Window @ Kitchen Sink (Some Location) A * New Impact window same size as O� existing, 53" X 37" * FL14608.6 / V * Repair any Wall or Drywall Damage LU * Paint Walls & Trim Location of window replacement: Kitchen window ,iln.back of home W! Work To Conform To FBC, 2017 6th Edition Cooke Construction, Inc. Scope of Work Job: Hodges GRenovation Division Window Replacement CGC1520585 Owner: Hodges Date: March 28, 2019 1276 NE Business Park Place Phone: (772) 530-0659 Address: 4115 S. Indian River Drive Drawn By: Nathan Cooke Jensen Beach, FL 34957 Fax: (772) 334-9911 Fort Pierce, FL 34982 Sheet #: 3 of 3