Loading...
HomeMy WebLinkAboutUTILITY STRUCTURE PLANi. APPROVED PRODUCTS LIST GENERAL NOTES: - 1. THESE PLANS PERTAIN ONLY TO THE STRUCTURE, INCLUDING MAIN WIND FORCE RESISTING SYSTEM, COMPONENTS AND CLADDING. AND BASE RAIL ANCHORAGE. OTHER DESIGN ISSUES, INCLUDING BUT NOT LIMITED TO PLUMBING. ELECTRICAL, INGRESS/EGRESS, PROPERTY SET -BACKS, FINISH FLOOR ELEVATION AND SLOPE, OR PRODUCT CATEGORY SUBCATEGORY MANUFACTURER APPROVAL OTHER LOCAL ZONING REQUIREMENTS ARE THE RESPONSIBILITY OF OTHERS. No. BDATE 2, THESE STRUCTURES ARE DESIGNED AS NON -HABITABLE UTILITY/STORAGE BUILDINGS (RISK CATEGORY I) CAPABLE OF SUPPORTING DEAD LOAD OF THE STRUCTURE AND APPLICABLE LIVE AND WIND LOADS. IMPROVEMENTS NOT SPECIFICALLY ADDRESSED HEREIN, INCLUDING DOORS, WINDOWS, OR OTHER COMPONENTS NOT LISTED STRUCTURAL COMPONENTS ROOF DECK CAROLINA CARPORTS, INC. FL6596.1-R5 IN THE FBC APPROVED PRODUCTS LIST (THIS SHEET), AND NOT PROVIDED AND INSTALLED BY CAROLINA CARPORTS, INC., WHICH EXERT ADDITIONAL LOADS ON THE 26 Gauge Panel 10/10/17 9 STRUCTURE SHALL BEAT THE OWNER'S RISK BECHTOL ENGINEERING AND TESTING, INC., SHALL NOT BE RESPONSIBLE FOR STRUCTURAL DAMAGE OR FAILURE DUE TO THE APPLICATION OF ADDITIONAL LOADS. STRUCTURAL COMPONENTS STRUCTURAL WALL CAROLINA CARPORTS, INC. FL6702.1-R5 3. ALL STEEL TUBING SHALL BE 50 KSI GALVANIZED STEEL. ALL FASTENERS SHALL BE GALVANIZED OR STAINLESS STEEL. 26 Gauge AG Panel 10/10/17 4. ALL COMPONENTS AND CLADDING SHALL BE INSTALLED ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS. 5. ALL FIELD FRAMING CONNECTIONS SHALL BE#12-14 x 3/4'SELF'DRILLING SCREWS WITHOUT CONTROL SEAL WASHER. ALL SHOP FRAMING CONNECTIONS SHALL BE WELDED. 6. CONCRETE SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 2500 PSI AT 28 DAYS. THE REINFORCING STEEL SHALL BE MINIMUM GRADE 40. CONCRETE SLAB FOUNDATIONS SHALL BE REINFORCED WITH 6X6-WI AXWI .4 WELDED WIRE FABRIC COMPLYING WITH ASTM A 185. OR WITH SYNTHETIC FIBER REINFORCEMENT COMPLYING WITH ASTM CI116. _ 7. CONCRETE ANCHORS SHALL BE WEJ-IT ANKR-TITE MODEL AT 1252. OR EQUIVALENT. 8. POST/RAFTER BRACING: BRACE ON EVERY POSTRRAFTER CONNECTION. EXCEPT FOR END WALLS AND GABLE ENDS. 9. SLAB FOUNDATION SUBGRADE SOILS SHALL BE TERMITE TREATED AND COVERED WITH 6 MIL VAPOR RETARDER PER SECTION R318.1 OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017)-RESIDENTIAL, AND SECTION 1816.1 OF THE FLORIDA BUILDING CODE SIXTH EDITION (2017) - BUILDING. MINIMUM ALLOWABLE FOUNDATION SOIL CONTACT BEARING PRESSURE OF 2,1 DO PSF IS ASSUMED. 10. 14 GA FRAMING: 2-1/2' x 2-1/2' TUBE STEEL ITS) WITH 2-1/4' x 2-1/4' TS NIPPLES. 12 GA FRAMING: 2-1/4' x 2-1/4' TS WITH Tx 2' TS NIPPLES. END. ELEVATION .. .. SCALE: 1/8' =1' SIDE ELEVATION SCALE: 1/O'=1' - - - - OCCUPANCYGROUP: U CONSTRUCTION TYPE: II-B RISK CATEGORY: I BUILDING ENCLOSURE TYPE: ENCLOSED WIND EXPOSURE CATEGORY: C ULTIMATE WIND SPEED (MPH): ISO NOMINAL DESIGN WIND SPEED (MPH): 116 MEAN ROOF HEIGHT (FEET): 7.46 ROOF ANGLE (DEGREES): 14.0 DESIGN PRESSURES (PSF): ROOF: ZONEI: +16.0 /-25.9 ZONE 2: +16.0/-36.5 ZONE 3: +16.0/-57.6 DESIGN ROOF PRESSURES: +16.0/,32A WALLS: ZONE4: +26.71-29.1 ZONES: +26.7/-32.5 DESIGN WALL PRESSURES: +26.71.30.1 1? FI +2.T REVIEWED FOR CODE COMPLIANCE $T• LUCIE COUNry NOTE: 14 GA FRAMING BOCC METAL FRAMING AND SIDING PREFABRICATED BY CAROLINA CARPORTS, INC. P.O. BOX 1263 DOBSON, NORTH CAROLINA 27017 THIS IS TO CERTIFY THAT THE CALCULATIONS AND SPECIFICATIONS HEREIN HAVE BEEN PREPARED BY THE UNDERSIGNED PROFESSIONAL ENGINEER, AND ARE IN ACCORDANCE WITH THE REQUIREMENTS OF SECTION 1609 OF THE FLORIDA BUILDING CODE, SIXTH EDITION (2017). THE PLANS ARE VALID UNTIL THE NEXT REVISION OF THE FLORIDA BUILDING CODE. BECHTOL ENGINEERINCZ 605 WEST NEWYORK AVENUE DELAND. FLORIDA 32720 =. i BY St. Lucie County \�Illll lll./// No, 3853 � STATE OF ; •' (v � ��''�Sy�NAL1ETG PROPOSED UTILITY STRUCTURE 5312 BOWLING GREEN DRIVE FORT PIERCE, FLORIDA ;. - m .. - . 21131 BECHTOL ENGINEERING RR "' RR NTSMOL . AND 7ESANG GiF � � ' TB. "dn G19C dY...'Nnn®® wwam TR CMFFTI INSTALL 1/2' x MINIMUM 5' EXPANSION ANCHOR THROUGH BASE RAIL WITHIN 6' OF EACH RAFTER POST ALONG SIDES AND INSIDE EVERY OTHER END WALL POST ALONG END WALL SECTIONS \ I---I-MIN. 6' MINIMUM 4- CONTINUOUS B CONCRETE PAVEMENT CONCRETE BASE RAIL ANCHORAGE t NMTO Scale SIDE RAFTER/POST FRAMING PLAN SCALE: 1/8' = V 48' 16 GA U-CHANNEL BRACE BRACE ANGLE SHALL BE MIN. "W RAFTER �S' LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x 3f4' SDFs RAFTER POST BOX EAVE RAFTER/POST DETAIL � NM TO Scale 26 GA. GALVANIZED METAL ROOF PANELS FASTENED TO RAFTERS ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS NIPPLE TO BASE RAIL 6' LONG TS NIPPLE SECURE POST TO NIPPLE WITH (4) #12-14 x 3W SDFs RAFTER POST CONTINUOUS BASE RAIL OSTBARAIL CONN. DETAIL 26 GA. GALVANIZED METAL WALL PANELS FASTENED TO POSTS ACCORDING TO MANUFACTURER'S INSTALLATION INSTRUCTIONS 12 Q3 TYPICAL INTERIOR POST/RAFTER FRAME SECTION SCALE: 1/8' =1' 2-1W FOR 12 GA FRAMING 2-112' FOR iB GAUGE U-CHANNEL BRACE FASTENED TO THE POST AND RAFTER WITH (2) #12-14 x 314' SDFS AT EACH END (4 PER BRACE) - BRACE SECTION Not To Scale \\111111111 ///' BECHTOL ENGINEERIIN TE TING, C. .01 605 WEST NEW YORKAVEZE DELAND. FLORIDA 32720 No. 38538 CemficeteofAoiho' bon No. lg'omon �'•. STATE ATE OF ce�• `Florldsuns 3{ �''/S�ONAL TEN PROPOSED UTILITY STRUCTURE 5312 BOWLING GREEN DRIVE FORT PIERCE, FLORIDA BECHTOL ENG/NEER/NG �RR AND TE6AND.T. ,•y m® wmxvs omm«rx oewmowru. us wtwus tome Dams d.rewa.n..w�m .a.wm TB 2 219 NTS SHEET 2 OF 2