Certification for Design Load Compliance By
Project Name: SHAT POSTS St. Lucie County
Project Address: 225 NETTLES BLVD
Permit#: Occupancy Type: R Construction Type: V
INSTRUCTIONS FOR USE:
• This certification must be completed, signed, and sealed by the design professional of record.
• Submit (2) copies for residential, (3) copies for commercial with all permit applications involving the following:
o New Residences (single or multi -family)
o Residential Addition
o Any accessory structure requiring a building permit
o Any non-residential structure.
: Note: Form not required for interior renovations provided that no exterior structural elements are affected and
certain minor building permits at the discretion of the local building official. Contact the # above for questions.
DESIGN PARAMETERS AND ASSUMPTIONS USED: (complete all that a
1. DESIGN CODE: Florida Buildine Code 2017 Edition with 20 _Supplements using ASCE 7-10
2. Structure Designed as (check one): _ Enclosed X Partially Enclosed _ Open
3.Risk Category: _I X li_III_IV Exposure Category: _B_C X D
4. Design Wind Velocity 165 mph 228 ASD N/A LRFD End Zone Width: 5 ft
S. Mean Roof Height: 11.6 ft Roof Pitch: N/A :12 Parapet: N/A ft
6. Components & Gadding Design Pressures Used: (PSF, based on 10sgft @ 15'MRH, clearly label on all plan openings):
Zone 1: 38.6 Zone 2: 38.6 Zone 3: 38.6 Zone 4: 56.9 Zone 5: 56.9 Garage: N/A
53.2 -82.6 115.7 -60.6 -71.6 N/A
7. Design Loads: Floor: N/A PSF Roof/Dead: N/A PSF Roof/Live: N/A Balcony:. N/A PSF
Dock: N/A PSF Deck: N/A PSF Stairs: N/A PSF Fence: N/A PSF Railings: N/A PLF / CONCENTRATED
S. Were Shear Walls Considered For Structure? X Yes _Not Applicable Explain Why Not
9. Is A Continuous Load Path Provided? X Yes _Not Applicable Explain Why Not:
10. Design Soil Bearing Pressure: Z500 PSF Soil Test Reports Submitted? _Yes
DESIGN PROFESSIONAL CERTIFICATION STATEMENT:
I certify that, to the best of my knowledge and belief, the attached plans & specifications have been designed to
comply with the applicable structural portions of the building codes currently adopted and enforced by St. Lucie
County. I also certify that structural elements depicted on these plans provide adequate resistance to the design
forces specified:
47.
�- 4/2/2019
Signature, Date nd Seal.
SLCCUV Form # b20-12•iievisetl 3/Sb/3.2 (is)
Paul Welch P.E.
Print Name
Paul Welch Inc.
29945 / 5115
Cert # & Co. Cert Auth.
1984 S.W. Biltmore St. Suite #114 Port St. Lucie, FL
Company Name & Address