Loading...
HomeMy WebLinkAboutEVALUATION REPORTProduct Evaluation Report SCANNED BY GULF COAST SUPPLY & MANUFACTURING, LLC. St. Lucie County 26 Ga. GulfLokTM 16" Wide Roof Panel over 15132" Plywood Florida Product Approval #11651.16 R3 Florida Building Code 2017 REVIEWED FOR LE COPY Per Rule 61 G20-3 CODE COMPLIANCE Method: 1 —D ST. LUCIE COUNTY ge��,4t &0 Y- too0� BOCC Category: Roofing Subcategory: Metal Roofing Compliance Method: 61G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 Engineer Evaluator: Dan Kuhn, P.E. #75519 Florida Evaluation ANE ID: 10743 Validator: Locke Bowden, P.E. #49704 9450 Alysbury Place Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 FL# 11651.16 R3 • OCTOBER 5. 2017 �,11u111#00 *:• No.75519STA= o R 0 P ��4Q: 'SNAL ENG% n `•• ' � � I I � � � , % %yo/05/201YL Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Product Description: GulfLokTM, 75" Nailstrip Roof Panel, Minimum 26 Ga. Steel, Maximum 16" Coverage, Roof panel restrained with fasteners into minimum 15/32" plywood decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2017 Section 1507.4.3. Paint Finish Optional Yield Strength: 50.0 ksi Corrosion Resistance: Panel•Materiahshall comply with Florida Building Code 2017, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 16" Coverage Maximum Female Rib: 7/a" Tall Male Rib: 3/a" Tall Rib with Slotted Strip Panel Seam: Snap Lock Panel Clip: Panel Fastener: Substrate Description: Design Uplift Pressures: 24 Ga. Zinc Aluminum Coated Steel, 24" Long. Used at Corner Zones only, where required design pressures exceed-121.75 psf. Through Panel Slot: (1) #10-12x1" Pancake Type A 1/4" Minimum Penetration through Plywood. Corrosion Resistance: Per Florida Building Code 2017, Section 1506.6, 1507.4.4 Minimum 15h2" thick, APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/ Florida Building Code 2017. Table "A" Maximum Design Pressures R"owo fTA77E Assembly A Assembly B Assembly C Maximum Design Pressures -63.5 psf -121.75 psf -161 psf Fastener Spacing Sealant No Yes No Panel Clip No No Yes •Design Pressure includes a Safety Factor = 2.0. _ i .N' Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2017, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2017, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06 - Test for Uplift Resistance of Roof Assemblies • UL 1897-12 - Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94 / 1897-98 Uplift Test Force Engineering & Testing, Inc. (FBC Organization # TST-5328) Report No. 117-0301T-10A-C, Dated 07/26/2013 2. TAS 125 Architectural Testing, Inc. (FBC Organization # TST-1527) Report No. 89000.01-450-18, Dated 12/122012 3. Certificate of Independence By Dan Kuhn, P.E. (FL# 75519) @ Kuhn Engineering, LLC (FBC Organization # ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-12 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3) for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2017, including Section 1507.4.2 and in accordance with Manufacturers recommendations. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2017 section 1507.1.1. Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. FL# 11651.16 R3 • OCTOBER 5, 2017 iN' 11 W re X Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. ENGINEER LOAD TABLE: 26 Ga. GulfLokTM 16" Wide Roof Panel over 15/32" Plywood Bulldings"haVlhg"a' oof Meari Height < 20'-0'; Roof Slope 2'712" 12 /12" Gable or Hip Roof; Wind Speeds 120- 180rf#;_Ezpcsure:C, Risk,Category II Enclosed Building, basedlon Florida Building Code 2017 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE SPEED (MIN. 1/4' Penetration) (MIN. 15/32") ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING 70NE 1 (1) #10 12)d CDX ASSEMBLY A ASSEMBLY A I ASSEMBLY A I 'ASSEMBLY A I ASSEMBLYA ASSEMBLYA ASSEMBLYA . PLYWOOD ZONE2 (1)#10-12x1"PLYWOOD COX ASSEMBLYA AS5EMBLYA ASSEMBLYA ASSEMBLYA ASSEMBLYA ASSEMBLYB ASSEMBLY ""•ZONE 3'' Y1) #10 12xY, aYWOOD ASSEMBLY AB 'ASSEMBLYA ASSEMBLY Ba `ASSEMBLY"B' ASSEMBLY.IB ASSEMBLY B ASSEMBLYIB`. 1.) PANEL DESCRIPTION: GULFLOKTM, MIN. 26 GA, 718" RIB, 16" MAXIMUM COVERAGE, SNAP SEAM. 2.) PANEL FASTENER: THROUGH PANEL SLOT (1) #10-12X1" PANCAKE TYPE A, 1/4" MIN. PENETRATION THROUGH PLYWOOD. 3.) MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: -63.5 PSF AT SW O.C. ASSEMBLY A,-121.75 PSF AT 5Ye" O.C. WITH SEALANT ASSEMBLY B, -161 PSF AT 5Ye" O.C. WITH CUP ASSEMBLY C. PRESSURE BASED ON UL 580/UL 1897 TESTING BY FORCE ENGINEERING & TESTING. 4.) PLYWOOD DECKING: MIN. t5hu" THICK, APA RATED PLYWOOD, GRADE C-D. MUST BE DESIGNED IN ACCORDANCE WITH FBC 2017 5.) LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10 (KD = 0.85) MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2017. ZONE2 ZONE d ---------- n / `� \♦ /1 RIDGE >---------� i ZONE NI EAVE GABLE ROOF -------------------- ZONE 1 -------------------- 3 Note: Dimension (a) is defined as 10% of the minimum width of the building or 40% of the mean height of the roof, whichever is smaller, however, (a) cannot be a less than either 4% of the minimum width of the building or 3 feet. ASSEMBLYA 16"COVERAGE (1) #10-12 X 1' TYPE A PANCAKE SPACING: SEE UPLIFT TABLE ASSEMBLY B 1/4'-5/15' DIAMETER BEAD OF TITEBOND SEALANT �a (1) #10-12 X 1' TYPE A PANCAKE SPACING: SEE UPLIFT TABLE a ASSEMBLY C W/CLIP GuRLok" CLIP 24 GA. (1) #10-12 X 1-TYPE A PANCAKE SPACING: SEE UPLIFT TABLE