HomeMy WebLinkAboutPLAN67'-7" EXISTING SUPPORT TO BE REMOVED NEW SUPPORT 10, 80'-2" EXISTING JOIST / TRUSS LAYOUT SUPPORTED BY TRUSS AND COLUMN STRUCTURE DESIGNED IN THESE PLANS PROJECT DION RESIDENCE 9'-7" 1550 BUTTONBUSH CIRCLE, PALM CITY, FL 34990 INTERIOR STRUCTURAL SUPPORT 14'-2" 12'-7„ TRIBUTARY AREA OF JOIST / TRUSS STRUCTURE SITTING ON MAIN TRUSS SCOPE 1 41'-8" — PROJECT NO.: DRAWi J19113 JS DATE: 05/09/19 FLOORIPLAN 1' = 3/32„ i CHECKED BY: jcg4 wool 44'-11 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY 13OCC .�oS`�„ �....... ..,,, 3 w No: 86388: */ .p? . SPATE OF .�.�`�•�. bill_ JOSEPH SIMHON, P11Yniu6oW PROFESSIONAL ENGINEER FLORIDA REGISTRATION #86388 KEY PLAN NTS SCOPE OF WORK SCOPE 1: TO INSTALL A NEW SUPPORT COLUMN AND FOUNDATION SYSTEM TO SUPPORT EXISTING ROOF TRUSS STRUCTURE AS DEPICTED IN PLANS HERE. DUE TO STRUCTURAL FRAMING ELEMENTS OF THE EXISTING CONSTRUCTION BEING HIDDEN FROM VISUAL OBSERVATION, CONTRACTOR TO CONFIRM AT THE TIME OF DEMOLITION THE CONDITION OF THE FRAMING AND STRUCTURAL ITEMS ASSUMED HERE AND COMMUNICATE WITH ENGINEER. DEVIATIONS SHOULD BE NOTIFIED TO ENGINEER SO THAT HE MAY EVALUATE THE CHANGED CONDITIONS AND ISSUE REVISED DRAWINGS WITH APPROPRIATE MODIFICATIONS, IF WARRANTED. ALL WORK MUST COMPLY WITH THE FLORIDA BUILDING CODE, SIXTH EDITION (2017) AND APPLICABLE STANDARDS OF THE AMERICAN CONCRETE INSTITUTE (ACI) INCLUDING, BUT NOT LIMITED TO ACI 315 AND ACI 31 B. SCANNED BY St. Lucie County QuEST CA# 7954 QuEST Engineering Services & Testing, Inc. 2737 NW 19 Street Pompano Beach, FL 33069 IN I Ph (954)582 9800 Fax (954)582 9836 Consulting - Engineering - Testing S.1 INSTALL NEW TRUSS TO MATCH EXISTING MEMBER SIZES 10"X10"XO.5" STEEL END PLATE WELDED TO COLUMN 4-3/4" HIT—V WITH HILTI HIT EQUIVALENTY100 OR EMBEDDED AT 6" 2'0X4.5' DEEP CONCRETE FOOTING (3000 PSI) VERIFY 2500 PSF SOIL BEARING CAPACITY INSTALL TWO 9FT C4X5.4 9' CHANNELS ON EITHER SIDE S2 OF TRUSS — EXST. 2X6 TOP CHORD 1 NEW TRUSS EXISTING TR S_ _ EXST. 2X4 DIAGONAL CHORD 1 _ EXST. 2X4 VERTICAL CHORD 2' 3" / I I �,� I /,/ / EXST. 2X4 BOTTOM CHORD EXISTING CMU WALL S4 INSTALL TWO 1OX10 TRUSS 7 NAIL ON PLATE W/16 0.131" TRUSS NAILS ON EITHER SIDE 4'-7" V. OF TRUSS 12'-7" S2 13' HSS 4"X4"X1/4" MAX. 13' HEIGHT MIN. 50 KSI STEEL COLUMNS ON EITHER SIDE OF OPENING S3 S3 1/4"0 FILLET WELD ALL AROUND (E-70XX ELECTRODES) #4 REINFORCEMENT REINFO AL CEMENT 7 S� SUPPORT ELEVATION 4' 1' = 1/4" I a L_ 2'OX4' DEEP CONCRETE FOOTING (3000 PSI) 3" MIN. 8 — #6 VERTICAL COVER REINFORCEMENT #4 SPIRAL TIES ®14"O/C 10"X10"XO.5" STEEL END PLATE WELDED TO COLUMN I.. t HSS 4"X4XO.25" COLUMN Ni S3 FOUNDATION TOP VIEW 1' = 1/4' DION RESIDENCE 1550 BUTTONBUSH CIRCLE, PALM CITY, FL 34990 INTERIOR STRUCTURAL SUPPORT INSTALL TWO 9FT C4X5.4 CHANNELS ON EITHER SIDE OF TRUSS PREDRILLED FOR BOLTING TO COLUMN 5"X8"X1/2" THK BASEPLATE 1/4" FILET WELD TO COLUMN INSTALL 4-3/8"0 BOLTS HSS 4"X4"X1/4" 50 KSI STEEL COLUMNS GENERAL NOTES INSTALL TWO 9FT C4X5.4 CHANNELS ON EITHER SIDE OF TRUSS 1/2"0 THROUGH 2. BOLT SPACED 12" OC 3. 4. 5. INSTALL TWO 9FT C4X5.4 CHANNELS ON EITHER SIDE 6. OF TRUSS PREDRILLED FOR BOLTING TO COLUMN 7, 4-3/8"0 BOLTS 18 5"X8"X1/2" THK BASEPLATE 1/4" FILET WELD TO COLUMN 9 HSS 4"X4"X1/4" 50 KSI STEEL COLUMNS S2 SECTION DETAIL 1' = 1 1 /2" S4 BASEPLATE DETAIL 1' = 1 1 /2" OJECT NO.: DRAWN BY: J19113 JS DATE: 05/09/19 CHECKED BY: RNS 3/4" MIN. EDGE DISTANCE % w No. 86388 6. STATE OF '-,,� FPS ........• G ,�`' JOSEPH SIMHON, PROFESSIONAL ENGINEER FLORIDA REGISTRATION i/86388 ALL WORK MUST COMPLY WITH THE FLORIDA BUILDING CODE, SIXTH EDITION (2017) AND APPLICABLE STANDARDS OF THE AMERICAN CONCRETE INSTITUTE (ACI) INCLUDING, BUT NOT LIMITED TO ACI 315 AND ACI 318. ALL WORK TO BE DONE BY LICENSED PERSONNEL AFTER OBTAINING APPROPRIATE PERMITS, PURSUANT TO ALL OSHA REQUIREMENTS CONCRETE COMPRESSIVE STRENGTH SHALL BE A MIN. OF 3000 PSI. STEEL CHANNELS AND OTHER MISCELLANEOUS STEEL SHOULD HAVE A MINIMUM YIELD STRENGTH OF 50 KSI. ALL WELDS TO BE DONE FULL LENGTH WITH 1/4"0 E-70XX ELECTRODES. IF THERE ARE GAPS UNDERNEATH BASE PLATE THEN PLACE 3000 PSI NON —SHRINK GROUT. IN THE EVENT OF ANY DISCREPANCY OR DISTRESS NOTED DURING CONSTRUCTION OPERATIONS, THE ENGINEER SHOULD BE NOTIFIED, IMMEDIATELY FOR RESOLUTION AND APPROPRIATE MODIFICATIONS TO THESE RECOMMENDATIONS, THAT THE ENGINEER DEEMS NECESSARY. CONTRACTOR TO INSPECT & VERIFY THAT OTHER AREAS OF THE STRUCTURE INCLUDING AREAS OUTSIDE OF WORK SCOPE ARE IN GOOD CONDITION AND DOES NOT REQUIRE ADDITIONAL REPAIRS. SUPPLEMENTAL SUPPORTS & SHORE POSTS MUST BE INSTALLED BEFORE CUTTING OR REMOVING ANY MEMBER. QuEST QuEST Engineering Services & Testing, Inc. 2737 NW 19 Street Pompano Beach, FL 33069 Ph (954)582 9800 Fax (954)582 9836 Consulting - Engineering - Testing CA# 7954 S-2