HomeMy WebLinkAboutEVALUATION REPORTEXTERIOR RESEARCH is DESIGN, U.C. Certificate of Authorization X9503 353 CHRISTIAN STREET, UNIT#13 -17f�;` OXFORD, CT 06478 PHONE: (203) 262-9245 SCANNED FAX: (203) 262-9243 EVALUATION REPORT BY East Coast Metals, Inc. Evaluation Report €10240.08.0R-R4 FL5374-R4 2301 West 8 Lane 08 Hialeah, FL33010 Date oRevisi n 4: 03/17/2015 Revision 4: D3/17J2015 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein. DESCRIPTION: East Coast Metals Channel Metals LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E- if the product changes or the referenced Quality Assurance documentation changes. Trinity lERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words `TrinitylERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPI¢rnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7. Prepared by: Robertl.M. Nieminen, P.E. Florida Registration No. 59.166, Florida DCA ANE1983 Thp faehnaasealaDPeasinywasaPliurv2tl tJ P.obm'%Iaminen, P.E vn®/1TP-a15. GIs does no:se�sx asanelec:tenkabYsI.lh FmduC Mmja ldn.r Id .th,e beensraiumJaetlsv;ha Pmdutl Approval AdminitiR:m and sv :he named [Tien: CERTIFICATION OF INDEPENDENCE: 1. Trinity] ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record far any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ROOFING COMPONENT EVALUATION: 1. 2. 3. 4. .! r `� 1-1-1 SCOPE: Product Category: Roofing Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS: Section Property Standard Year 1507.3.7 Installation,non-Ht7HZ FRSA/TRI April 2012(04-12) 2012 3518.8.1 Installation, HVHZ RA5118, 119&120 1995 1523.65.21 Static Uplift Resistanre TAS 101 1995 171L21 Static Uprift Resistance SBCO S51-D1.1 1997 REFERENCES.- gnifty Examination Reference Date ERD(TST6049) Static Uplift Resistance E42730.08.3 08/23/2013 ERD UST60491 Static Uplift Resistance ECNI-SC679512.14-1 02/27/2015 ERD(TST6049) Static Uplift Resistance EClvl-SC6795.12.14-2 02/27/2015 Florida TEC ITST7393) TA5101 S30c2SR 10/27/2010 PRI (TST5878) TA5101 ECM-001-02-01 09/21/2001 PRI (TST5878) TAS101 ECNI-003-02-01 06/23/2008 PRI(TST5878) TAS101 ECrri-004-02-01 05/13/2008 PRI(TS75878) TAS 101 ECM-005-02-01 06/13/2009 PRI (TST5878) TAS101 ECM-006-02-01 06/13/2008 PRI(TST5878) TAS101 ECM-007-02-01 06/13/2009 PRI(TSTS878) TA5101 ECM-008-02-01 06/13/1008 Florida Building Code Attachment Requirements FRSA/TRI April 2012(04-12) 0412032 Florida Building Code -HVHZ Attachment Requirements RA5118,119 and 120 1995 East Coast Metals Metal Quality Mill Certifications Various Architectural Testing(QUA1844) Quality Control Participation Letter Exp.12/31/2018 PRODUCT DESCRIPTION: 4.1 Hip & Ridge Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved fODftlle adhesive. Hip & Ridge Channel Metal is available in 119-3/8-inch (± 3/8-inch) length by 2-5, 3, 3.5, 4, 5, 6 or 7-inch L 3/8-inch) heights with 1.5-inch (* 1/16-inch) deck -flanges. Exterior Research and Design, LLC. Evaluation Report E10240.08.08-114 Certifimte afAutharfzodon #9303 F/1712015 Revision 4: 03/17/2015 Page 2 of 7 TRINITY ERD 4.2 Trim Lock Channel Metal: Pre -farmed metal channel designed for use as a hip and ddge base to which roof tiles are bonded in FBC Approved roof file adhesive. Trim Lock Channel Metal Is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying tile adhesive. Trim Lock Channel. Metal is available in 119-3/8-inch (+ 3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights with 1.5-inch (±1/16-inch) deck -flanges. 4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel designed for use as a hip and ridge base to which roof tiles are bonded in FBC Approved roof file adhesive. Trim Lock Plus Channel Metal is characterized by its profiled and perforated upper horizontal flange designed to receive and allow for interlock with the overlying file adhesive and its perforated deck flanges, designed for installation atop the roof underlayment via placement in FBC Approved roof tile adhesive, which flows -through and interlocks with the underlying adhesive. Trim Lock Plus Channel Metal is available in 119-3/8-inch (±3/8") length by 3, 3.5, 4, 5 or 6-inch L3/8-inch) heights with 1.5-inch (±1/164ncli) deck -flanges. 4.4 East Coast Metals Channel Metals are fabricated of the following metals: ➢ Galvanized Steel: Min, o.019±0.002-inch, ASTM A653 (G-90), min. 33 KSI. i ➢ Galvalume Steel: Min. 0.019±0.002-inch, ASTM A792, AZ55, min. 35 KSI. > Aluminum: Min. 0.032±0.002-inch, ASTM B209, 3003-N14, min. 21 KSI. > Stainless Steel: Mirj. 0.019±0.002-Inch, A5TM A240/A480, T304, min. 35 KSI. 5. LIMrrwiciNs: 5.1 This is a building code evaluation. Neither Trinityl ERD nor Robert Nleminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. Exterior Research and Design, I.I.C.Evaluation Report E10240.08.08-R4 FL5374-R4 C&rificute ofauthoructiun 9950 Revision 4: 03/17/2015 Page 3 of 7 TRINITY ERD 5.2 FOR HVHZIURISDICrIONS: 5.2.1 For Hip & Ridge Channel Metal or Trim Lack Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock -Plus Channel Metal, refer to the installation instructions herein. 5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and 120, and the data in Tables IA and 1B is supplemental to these prescriptive allowances. Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,J or uplift resistance (F,), as determined in accordance with RAS 127, not greater than the following values. Referto the file adhesive manufacturer's published installation instructions for adhesive paddy placement details. 1'• "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single foam paddy; file head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. S "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the rile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. _ - TABLE SA: PERFORMANCE DuRTATIONs-HVHZ, INDEPENDENT PADOYPLACEMENT - (2TOIMAFGINOFSAFE ArRFADYAPPOEO) Hip/Ridge Metal Tile Adhesive Allowable Performance Design Metal Type Type Placement Moment Moment Based Uplift Based (ft-lbf) F' (Ibf) Hip &Ridge galvanized clayar 3 Vi- 2-Component Foam Independent 127 169 Channel Metal concrete Roof Tile Adhesive AN-160 Trim Lock galvanized, Galvalume-, day or 31101"' 2-Component Foam Independent 171 159 aluminum or stainless steel concrete RoofTle Adhesive AH-160 Trim Lock Plus galvanized, Galvalumea, dayor 310'2-Component Foam Independent 177 165 aluminum or stainless steel concrete Roof Tile Adhesive AH-160 _ TABLESB: PERFORMANCE LiMrrATION5-HVHZ, INTERDEPENDENT PADDY PLACEMENT - -- (4mI MARGIN OFSAFETYALRFApYAVIUM) Hip/Ridge Metal Tile Adhesive Allowable Performance Moment Based Uplift Based Design Metal Type Type Placement MI(ft-Ibf) F'(Ibf) Trim Lock or Trim galvanized, Galralumeo, day or 3M"'2-Component Foam Interdependent 95 88 Lock Plus aluminum or stainless steel Concrete Roof Tile Adhesive AH-160 Trim Lock galvanized, Galvalumeo, day or 3M'" Roof Tile Adhesive Interdependent 99 94 stainless steel Concrete RTA-1 Trim Lock aluminum day or 3M"' Foam Roof Tile Interdependent 90 84 concrete Adhesive RTA-1 Trim Lock Plus galvanized, Galvalume", day or 3M'" Foam Roof Tile Interdependent 90 84 aluminum or stainless steel Concrete Adhesive RTA-1 galvanized, Galvalume-or day or TILE BOND'" Roof Tile Trim Lack stainlesssteel Concrete Adhesive Interdependent 123 117 Trim Lock aluminum day or TILE BOND" Roof Tile Interdependent 79 73 Concrete Adhesive Trim Lock Plus galvanized, Galvalume', day or TILE BOND"' Roof Tile Interdependent 79 73 aluminum or stainless steel concrete Adhesive galvanized, Galvalumee or day or Touch'n Seal StormBond Trim Lock stainless steel concrete Roof Tile Adhesive Interdependent 146 139 Trim Lock Aluminum day or Touch'n Seal StormBond Interdependent 58 54 concrete Roof The Adhesive Trim Lock Plus galvanized, Galvalume°, day or Touch'n Seal StormBond interdependent SB 54 aluminum or stainless steel concrete RoofTle Adhesive Exterior Research and Design, LLG Evaluation Report E10240.08.08-114 Certifoote of Authoruation#9503 . FLS374•114 Revision 4:03/17/2015 Page 4 of 7 5.3 FOR NON-HV14Z JURISDICTIONS: 5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lack Plus Channel Metal, refer to the installation instructions herein 5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile adhesive manufacturers published installation instructions for adhesive paddy placement details. D "INDEPENDENT' paddy placement means each individual the is bonded to the Channel Metal in its own, single foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT' paddy placement already has a 2 to 1 margin of safety applied to ultimate performance. ➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy, and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single foam paddy. Allowable performance data below for "INTERDEPENDENT' paddy placement already has a 4 to 1 margin of safety applied to ultimate performance. TABLE 7A:. PERFORMANCE LIMrrATiON5—NON-HVHZ, INDEPENDENT PADDY PLACEMENT (2 TO 1 MARGIN OFSAFETY ALRFADYAPPDED) . Hip/Ridge Metal Tile Adhesive Allowable Uplift (Psf) Design Metal Type Type Placement Hip &Ridge galvanized day or 310-2-Component Foam Roof Independent 169 Channel Metal concrete Tile Adhesive AH-160 Trim Lock galvanized, Galvalumea, aluminum or clay or 3MTM 2-Component Foam Roof Independent 173 stainless steel concrete Tile Adhesive AH-160 Trim Lock Plus galvanized, Galvalume-, aluminum or clay or 3M'"2-Component Foam Roof Independent 178 stainless steel concrete Tile Adhesive AH-160 T ABLE 29: PERFoRMANu llmnAnoNs—NUN-HVHZ, fN omuENDENT PADDYPLACEMENT(4 TO 1 MARGIN OF5AFE7YALFMADYAPPDED) Hip/Ridge Metal Tile Adhesive Allowable Uplift (Psf) Design Metal Type Type Placement Trim Lock or-Frim galvanized, Galvalume®, aluminum or day or 3MTM 2-Component Foam Roof Interdependent 98 Lock Plus stainless steel concrete Tile Adhesive AH-160 Trim Lock galvanized, Galvalume or stainless day or 3MTM Foam Roof Tile Adhesive Interdependent ll0 steel concrete RTA-1 Trim Lock aluminum day or 3MTM Foam Roof Tile Adhesive Interdependent 93 concrete RTA-1 Trim Lock Plus galvanized, Galvalume°, aluminum or day or 3MTM Foam Roof Tile Adhesive Interdependent 93 stainless steel concrete RTA-1 Trim Lock galvanized. nized. Galvalume' orstainless clncrete TILE BOND— Roof Tile Adhesive Interdependent 152 Trim Lock aluminum day or TILE BOND- Roof Tile Adhesive Interdependent 82 concrete Trim Lock Plus galvanized, Galvalume-, aluminum or day or TILE BOND- Roof Tile Adhesive Interdependent 82 stainless steel concrete Trim Lock galvanized, Galvalume- orstainless day or Touch'n Seal StamnBond Roof Interdependent 148 steel concrete Tile Adhesive Trim Lock Aluminum day or Touch'n Seal StormBond Roof Interdependent 61 concrete Tile Adhesive Trim Lock Plus Ea lvanized, Galvalume°, aluminum or day or Touch'n Seal StmmBond Roof Interdependent 61 stainless steel concrete Tile Adhesive Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4 c rtficae ofAurhorhadon d9503 FL5374-R4 Revision 4: 03/17/2015 _ _".._ __ . Page of7. TRINFIN ERD 6. INSTALLATION: . 6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in accordance with FBC Chapter 23 to the satisfaction of the AHJ. " 6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1Y-inch long z 3/9-inch head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges- Fasteners shall be positioned Y-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to FBC RA5119, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RA5120, Drawing 15, Detail 3. 6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet adhesive and allow it to set-up prior to installation of roof tiles. View of Polyset AH160 Placement for Trim Lack Plus Channel Metal Installation 63.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not disturbed prior to or during placement of the ridge tiles. 6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved use of the subject tile adhesive. Exterior Research and Design, I.I.C.Evaluation Report E10240.08.08-R4 [ertif ,ate ofAuthorizotian 99503 3117/2015 Revision 4: 03/17/20]5 Page 6 of 7 TRINW ERD 6.4 Tile shall be installed atop the Channel Metal in accordance with the the adhesive manufacturers Approved, published installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS 118, RAS 119, RAS 120 requirements. Hip / Ridge Tile Tile Adhesive Trim Lock Plus Mortar or Weather Block Adhesive Tile Adhesive View of Trim Lock Plus Channel Metal Installation after weather Blocked 6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance priorto placement of adhesive. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. B. MANUFACTURING PLANTS: Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements. 9. QUALITY ASSURANCE ENTITY: Architectural Testing, Inc.—QUA1844T (717) 764-7700 - END OF EVALUATION REPORT - Exterior Research and Design, LLc- renl(Imm afAurhorhadon 495013 Evaluation Report E10240.08.08-R4 FL5374-R4 Revision 4:03/17/2015 Page 7 of 7 EXTERIOR RESEARCH & DESIGN, I.I.C. Certifimte of Authorization #9503 SCANNED 353 CHRISTIAN STREET, UNIT#13 _ TRINITYERD BY OXFORD, CT 06478 St. Lucie County (203) 262-9245 EVALUATION REPORT nPoseel p° Entegra Roof Tile, LLC Imo' Evaluation Report E39310.11.11-1-R4 TEEGRA 1289 NE 9`s Avenue FL7804-R10 R O O F T I L C Okeechobee, FL 34972 Date of Issuance:12/02/2011 (602)515-6933 Revision 4: 10/17/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 15" Edition (2017) Florida Building Code (HVHZ) sections noted herein. DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions) LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. TrinityiERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity) ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The iaaimlk seal appearbi,.1au9hvrued by Robert Nkminen, P.E. on 10117/2017. Thts does notserce as an dedp n oegy signed document- Signed, sealed hardmples hate been t2nsmitled to the Product Approval Administmtarand to the named dent CERTIFICATION OF INDEPENDENCE: 1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING SYSTEM EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Roofing Tiles Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated compliance with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Pro a Standard Year 1523.6.5.2 Physical Properties TAS 112 1995 1523.6.5.2 Wind Driven Rain TAS 100 1995 1523.6.5.2.2 Static Uplift Resistance TAS 101 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102 1995 1523.6.5.2.3 Static Uplift Resistance TAS 102(A) 1995 3. REFERENCES: KnottExamination Reference Date ERD(TST6049) TAS 101 P39740.02.12 02/21/2012 ATL(TST3782) Physical Properties RT0624.05-14 07/03/2014 ATL(TST3782) Physical Properties RT0624.04-14 07/07/2014 ATL(TST3782) Physical Properties RT1210.02-15 12/17/2015 ATL(TST3782) Physical Properties RT1210.03-15 12/17/2015 ATL (TST 3782) Physical Properties RT1103.01-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.02-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.03-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.04-15 11/07/2015 ATL (TST 3782) Physical Properties RT1103.05-15 11/07/2015 Miami-Dade(CER1592) HVHZ Compliance 14-0416.12 11/27/2014 Miami-Dade(CER1592) HVHZ Compliance 15-0721.04 11/05/2015 Miami-Dade(CER1592) HVHZ Compliance 16-0112.06 02/2S/2016 Miami-Dade(CER1592) HVHZ Compliance 16-0112.07 02/25/2016 Miami-Dade(CER1592) HVHZCompliance 16-0112.08 02/25/2016 Tile Roof Institute TAS 100, TAS 101, 102, 102(A) Membership Confirmation Current PRI (QUA9110) Quality Assurance Service Confirmation Exp. 11/02/2018 Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 Certifmte o)Authoriiution 0503 6r"EDITION(2017) F8CHVHZ EVALUATION FL7804-R30 Entegra Roof Tiles Revision 4:10/17/2017 Page 2 of 8 4. PRODUCT DESCRIPTION: 4.1 I TAS 112, Type 3a (flat-profile)`'- 2' 10, Y Bermuda Flat Horizon Flat �17-1/4" TRINITY ERD PIANTATIONFIAT.and HORIZON FIAT Plantation Flat Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 Cenficote o)Authoruadon 09503 6TM EDITION(2017) FBC HVHZ EVALUATION FL7804-1110 Entegra Roof Tiles Revision 4: 10/17/2017 Page 3 of 8 4.2 TRINITY I ERD rTAS'112, Type la (interlocking, -high -profile) „ I BELLA HIGH "S" - Bella High "S" 4.3 1 TAS M. Twe lb (interlocking,.low=profile 4.3 1 TAS 17" Estate "S" Galena Spanish "S" 10" "S" and HACIENDA Hacienda GALENA SPANISH "S" and REGAL Regal Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 Cezuj7mre of Authorization M03 6r EDITION 12017) FBC HVHZ EVALUATION FL7804-1110 Entegra Roof Tiles Revision 4: 10/17/2017 Page 4 of 8 TRINITY' ERD 5. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used- - for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements. 5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for fire rating of this product. 5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations. 5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in accordance with TAS 112, Appendix'A'. 5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof assemblies in FBC HVHZ jurisdictions. 5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements. 5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule 61G20-3. 6. INSTALLATION: 6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall comply with manufacturer's current published instructions, but not less than the requirements of RAS 118, RAS 119 or RAS 120, as applicable. 6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in accordance with Roofing Application Standard RAS 127-11 using the data outlined herein. •,TABLEI:AERODYNAMICMULTiPUERS-H.(FT3)' - - �- - - Tile Batten Application Direct -Deck Application Bermuda Flat 0.189 0.205 Plantation Flat 0.267 0.299 Horizon Flat 0.305 0.330 Bella High "5" 0.349 0.378 Estate "S" 0.267 0.289 Hacienda 0.267 0.289 Galena Spanish "S" N/A 0.235 Regal 0.287 0.311 - TABLE 2: RESTORING MOMENT DUE TO GRAVITY a M. (FT -LBO)" Roof Slope (0) Tile 2:12<0<3:12 3:12<0<4:12 4:12<0<5:12 5:1250<6:12 6:12<0<7:12 0>7:12 Battens I Direct Battens Direct Battens Direct Battens Direct Battens Direct Battens Direct Bermuda Flat 5.22 6.43 5.17 6.37 5.09 6.27 4.98 6.15 4.86 6.00 4.72 5.83 Plantation Flat 7.22 7.91 6.85 7.79 6.75 7.67 6.61 7.52 6.44 7.32 6.26 7.04 Horizon 7.60 8.32 7.52 8.24 7.41 8.12 7.26 7.95 7.09 7.76 6.89 7.55 Bella High "S" 6.19 6.89 6.11 6.80 5.99 6.67 5.85 6.51 5.68 6.33 5.50 6.13 Estate "5" 6.14 6.84 5.91 6.74 5.82 6.64 5.70 6.50 5.56 6.33 5.40 6.14 Hacienda 5.92 6.80 5.92 6.80 5.82 6.61 5.70 6.55 5.56 6.39 5.41 6.22 Galena Spanish "5" N/A 6.20 N/A 6.13 N/A 6.03 N/A 5.89 N/A 5.74 N/A 5.57 Regal 7.77 8.34 1 7.77 1 8.34 7.65 1 8.20 7.49 1 8.03 7.30 1 7.83 1 7.10 1 7.61 Exterior Research and Design, LLC Evaluation Report E39310.=11-1-R4 Certry7mte ofAuthodradon p9503 Ern EDITION (2017) FBC HVHZ EVALUATION FL7804-R30 ____.. _.___.-.__-__Entegra Roof -Tiles __-_.____ _.__.__._.._..._.._.Revision 4:10/17/2017---- ___ Page 5 of a TRINITY ERD - TABLE 3A: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF(FT-LBF) - ' - "- MECHANICALLY ATTACHED SYSTEMS Tile Fastener Direct -Deck (min. 15/32" ,plywood) Direct -Deck (min. 19/52" plywood) Battens Type # Size Shank Clip Nail One (1) 10d Smooth or Screw N/A 73 9.8 4.9 Nail Two (2) 10d Smooth or Screw N/A 14.0 18.8 7.4 Nail One (1) 10d Smoothor Screw Eave 19.0 19.0 22.1 Nail One (1) 10d Smooth or Screw Field 24.3 24.3 24.2 Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Bermuda Flat, Plantation Flat or Nail Two (2) SOd Smooth or Screw Field 35.5 35.5 34.8 Horizon Nail Two (2) 10d Ring N/A 30.9 38.1 17.2 Nail' Two (2)' 10d' Ring' N/A 50.3' 65.5' 48.3' Screw One (1) 08 N/A N/A 30.8 30.8 18.2 Screw Two (2) #8 N/A N/A 51.7 51.7 24.4 ' Installation with a 4-inch tile headlap and fasteners located min. 2Y,-inch from head of tile. Nail One(1)2 10d Smoothor5crew N/A 8.82 11.8, 4.1' Nail Two (2) 30d Smooth or Screw N/A 16.4 21.9 7.1 Nail One (1)' 10d Smoothor5crew, Eave 19.0z 19.02 22.12 Nail One (1)' Sod Smooth or Screw Field 24.3' 24.32 24.22 Nail Two (2) 10d Smooth or Screw Eave 31.9 31.9 32.2 Nail Two (2) 10d Smooth or Screw Field 35.5 35.5 34.8 Estate "5" or Hacienda Nail Two (2) lud Ring N/A 2T8 37.4 28.8 Nail' Two (21' 1& Ring' N/A 43.0' 67-5' S0.9, Screw One #8 N/A N/A 25.82 25.82 22.92 Screw Two (2) #8 N/A N/A 47.1 47.1 49.1 'installation with a 4-Inch the headlap and fasteners located min, 2'A-inch from head of tile. ' For one (1) fastener installations, utilize hole that is approximately 4Y inch from the interlocking edge. Nail One (1) 10d Smoothor5crew N/A 5.1 6.8 2.8 Nail TWO (2) 10d Smooth orScrew N/A 6.9 9.2 7.3 Nail One (1) 10d Smooth or Screw Field 23.1 23.1 29.0 Nail One (1) SOd Smoothor5crew Eave 29.3 29.3 24.0 Nail Two (2) 30d Smooth or Screw Field 27.6 27.6 38.6 Bella High "S", Galena "S" Nail Two (2) 10d Smooth or Screw Eave 38.1 38.1 41.8 Spanish or Regal Nall Two (21 30d Ring N/A 28.6 41.2 19.4 Nall' Two (2), 10d' Ring' N/A 33.1' 48.1' 50.9' Screw One (1) #8 N/A N/A 20.7 20.7 18.1 Screw Two (2) 08 N/A N/A 43.2 43.2 29.8 ' Installation with a 4-inch tile headlap and fasteners located min. 2%4nch from head of tile. Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4 Certificate o/Authorizodon#95o3 6m EDITION(2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 6 of 8 TRINITY i ERD TABLE4: ATrACHMENT RESISTANCE EXPRESSED AS A MOMENT— MF(Fr-IBF) _ MORTAR AND ADHESIVE -SET SYSTEMS Nate fromEntegra Roof Tile, LLC.: The performance data listed in Table 4-are based on the respective adhesive manufacturers' test, reports and Miami -Dade NOAs. Entegra Roof rile, LLC. relies upon: the adhesive manufacturers to provide these: values for our inclusion in this FBC HVHZ Evaluation Report. Please. consul the individual adhesive manufacturer for information on productapprovals,_ limitations, revisions or other information for determining wind load and overturning moment performance..- - : - Tile Adhesive Tile Product Product Approval Placement Mf(ft-lbf) 'TILE BOND'"" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 41 Bermuda 'Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 73 Flat, •'Polyset® RTA-1" by ICP Adhesives& Sealants NOA 16-0315.03 Interdependent (2-paddy) 52 Plantation Fiat or Horizon "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent (2-paddy) 43 Independent (medium paddy, `30 g) 51 Independent (large paddy, -45 g) 92 'TILE BOND'"" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 44 'Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 42 "5" "Polyset° RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 44 Estate or Hacienda "Polyset® AH-160" by ICP Adhesives & Sealants NOA 17-0322.03 Interdependent(2-paddy) 50 Independent (medium paddy, -30 g) 37 Independent (large paddy,'"54 g) 61 Mortar Various Per RAS 120 21 'TILE BOND'"" by Dow Chemical NOA 16-0222.01 Interdependent (2-paddy) 48 'Touch N' Seal Storm Bond" by DAP Foam NOA 16-0421.03 Interdependent (2-paddy) 52 Bella High "S", "Polyset® RTA-1" by ICP Adhesives & Sealants NOA 16-0315.03 Interdependent (2-paddy) 36 Galena Spanish "S" or Regal "Polyset® AH-160" by ICP Adhesives & Sealants NOA17-0322.03 Interdependent (2-paddy) 30 (medium paddy,-30 g) 49 -Independent Independent (large paddy,-63 g) 94 Mortar Various Per RAS 120 25 7. LABELING: 7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. and/or ENTEURR Q�� Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S" Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4 CertllaneofAutft dwion#9503 OEDITION(2017) FBC HVHZ EVALUATION FL7804-R10 Entegra Roof Tiles Revision 4:10/17/2017 Page 7 of 8 TRINITY; ERD and/or Hanson Labeling: Horizon Flat, Hacienda, Regal 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Plant- "- „- . _- Profiles' -' Okeechobee, FL Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S' Ft. Myers, FL Horizon Flat, Hacienda Deerfield Beach, FL Horizon Flat, Hacienda, Regal 10. QUALITY ASSURANCE ENTITY: PRI Construction Materials Technologies, I.I.C. — QUA9110; (813) 621-5777 - END OF EVALUATION REPORT — Exterior Research and Design, U.C. Evaluation Report E39310.11.11.1-R4 certifimte ofAuthortradon 49503 6r" EDrnON(2017) FBC HVHZ EVALUATION FL7904-R30 Entegru Roof TIIes Revision 4! 10/17/2017 Page 8 of 8 RECEIVED APR 0 4 2010 Permitting Departm4nr �EOREIC#�. St. Lucie County Certificate of Authorization #32455 SCANNED 353 Christian Street, Unit#13 BY Oxford, CT 06478 to St. Lucie County (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY O. Boral Roofing Evaluation Report M35730.12.30-R11 7575 Irvine Center Drive, Suite 100 FL14317-R30 Irvine, CA. 92618 (602)269-2288 Date of Issuance: 12/21/2010 Revision 11:10/22/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Boral Roof Underlayments LAeEUNG: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: „"Y "^•,.,,-- Robert J.M. Nieminen, P.E. '.''.:.•�s P `f T:: s�s�*•ti _a�;i j.`,•' the facsimile seal appearing was authorized by Robert Florida Registration No. 59166, Florida DC4 ANE1983 Nieminen,P.E on 10/12/2011L This does not serve as an ' electronically signed document. CERnRCATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NNEMOletc. ROOFING COMPONENT EVALUATION: -1. SCOPE Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Boral Roof Underlayments, as marketed by Boral Roofing, have demonstrated compliance with the following sections of the 6t6 Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. STANDARDS:2. Section Pro a Standard Year 1504.3.1 Wind Uplift UL 1897 2012 1507.1.1, T1507.1.1, Physical Properties ASTM D1970 2015 1507.2.9.2 _ 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 Entity Examination Reference Date ERD (TST 6049) Physical Properties M36790.07.11 09/30/2011 ERD (TST 6049) Physical Properties B40380.08.12 08/28/2012 ERD M 6049) Tensile Adhesion / LTA C41420.09.12-2 09/11/2012 ERD (TST 6049) Adhesion B41940.09.12 09/13/2012 ERD (TST 6049) Tensile Adhesion / LTA B47390.07.14-1 07/31/2014 ERD (TST 6049) Tensile Adhesion / LTA B47390.09.14 09/04/2014 OC (PDM1638) Physical Properties Equivalency statement 11/02/2017 PRI (TST 5878) ASTM D1970 NEI-031-02-02:REV 10/27/2010 PRI (TST 5878) ASTM D1970 NEI-029-02-01:REV 12/03/2010 PRI (TST 5878) Tensile Adhesion / LTA NEI-046-02-01REV 12/17/2010 PRI(TST 5878) FRSA/TRI April 2012 NEI-076-02-01 02/14/2011 PRI (TST5878) ASTM D1970 NEI-034-02-02 01/29/2013 PRI (TST 5878) Wind Uplift BORR-001-02-01 03/17/2015 PRI (TST 5878) Wind Uplift BORR-005-02-01 06/24/2015 PRI (TST 5878) Tensile Adhesion / LTA DAPF-002-02-01 03/08/2018 PRI (TST 5878) ASTM D1970 (adhesion) OCF-443-02-01 10/11/2018 UL, U.C. (QUA 9625) Quality Assurance Service Confirmation Exp. 08/21/2020 4.1 BoralO TileSeal 50"T is a nominal 50-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D3970. 4.2 BoralO TileSealHT is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI 04-12. 4.3, BoralO MetalSealHT is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI 04-12. 4.4 GatorSeal® is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roof underlayment; meets ASTM D1970. 4.5 Citadel® Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM D1970. NEMO ETC, LLC Evaluation Report M35710.12.104122 Cerdjirare of Author&atron#32455 a EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RIO Bard[ Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 2 of 8 NNEm'oletc. 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting — or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Boral Roof Underlayments may be used with any prepared roof coverwhere the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof covers. Refer to the installation instructions for multi -ply underlayment options. ROOF COVEROPTIONS Underlayment Asphalt Nail -On Tile Adhesive -set Metal Wood Shakes Slate Shingles rile &Shingles Boral TileSeal Sow Yes No No Yes Yes Yes Boral TileSealm Yes Yes Yes yes Yes Yes (See 5.5.1) Boral MetalSealw Yes Yes Yes Yes Yes Yes (See 5.5.1) GatorSeal Yes No No No Yes Yes 5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations. Adhesive Florida Product Approval Underlayments DAP Foam Touch'n Seal Storm Band Roof Tile Adhesive FL14506 Boral TileSealw or Boral MetaLSealw DAP Foam Touch'n Seal StormBond 2 Two -Component Polyurethane Roof Tile Adhesive FL21374 Boral TileSeal"' or Baral MetalSealw Dow TILE BONDTM Roof Tile Adhesive FL22525 Boral TileSeal"' or Boral MetalSealw ICP Adhesives Polyset® AH-160 FL6332 Boral TileSeal"' or Boral MetalSealw ICP Adhesives Polyset® RTA-1 FL6276 Boral TileSealw` or Boral MetalSealw t Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report M35710.12-70-R31 Certiftwie ofAuthorizadon n32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R30 Boral Roof Underlayments: (602) 269.2288 Revision 11: 10/121201S Page 3 of 8 NNEW10letc. 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Citadel Plus, Boral TileSeal 50"T, Boral TileSeal"T, Boral MetalSeal"T or GatorSeal: ➢ Plywood (unprimed or primed with ASTM D41 primer). Boral TileSealHT or Boral MetalSealw: ➢ OSB (unprimed or primed with ASTM D41 primer). Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the overlying roof cover is adhesive -set file roofing 5.6.2 Bond to Base Laver Underlavment: Citadel Plus, Boral TileSeal 5011T, Boral TileSealn Boral MetalSealHr or GatorSeal: ➢ ASTM D226, Type II felt; Citadel Plus. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under adhesive -set tile systems, base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested in accordance with FBC 1504.3.1. 5.6.3 Bond to Other Substrate Types: Citadel Plus, Boral TileSeal 5011; Boral TileSeal"T, Boral MetalSeal"T or GatorSeal: ➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.). Boral TileSealHT: ➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime. Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. 5.6A Wind Resistance for Underlavment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads #1 Maximum Design Pressure = -120.0 post; Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 to the plywood deck Base Ply: Citadel Plus, self -adhered Cap Sheet: Boral TileSeal"T or Boral MetalSealln, self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 3Y<" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #2 Maximum Design Pressure = -242.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Ply: None Cap Sheet: Boral TileSealw or Boral MetalSeal"T, self -adhered and back -nailed within the selvedge -edge side laps using 12 ga. x IY4" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. NEMO ETC, LLC Evaluation Report M35710.12.10-R11 certfmte ofAuthormation R32455 6r" EDITION (2017) FBC NON.HVHZ EVALUATION FL14317-R30 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2028 Page 4 of 8 *NEMOletc. #3 Maximum Design Pressure=-202.5 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck Base Ply: None Cap Sheet: BoralTileSeal"TorBoral MetalSeal"n self -adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 3Y." ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #4 Maximum Design Pressure=-210.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: KARNAK #89 Sta-Tak Primer to the plywood deck Base Ply: None Cap Sheet: Boral TileSeal"TorBoral MetalSealHr,self-adhered, and back -nailed within the selvedge -edge side laps using 12 ga. x 1Y" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c. #5 Maximum Design Pressure=-120.0 psf: Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: ASTM D41 to the concrete deck Base Ply: (Optional) Citadel Plus, self -adhered Cap Sheet: Boral TileSealw or Boral MetalSeal"T, self -adhered 5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 5.7 Exposure Limitations: GatorSeal shall not be left exposed for longer than 30-days after installation, priorto placement of final roof cover. Boral TileSeal SO" ; Boral TIIeSealw or Boral MetalSealw shall not be left exposed for longer than 180-days after installation, prior to placement of final roof cover. Citadel Plus, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than 180-days after installation, prior to placement of subsequent underlayment layer. 5.8 Tile Slippage Limitations fFRSA/TRI April 2012 (04-12)1: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. FORDIREcT-DEcK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Boral TileSeal` or Boral MetalSealw atMax. 30-tile stack 6:12 Lugged Max. 30-tile stack 6:12 6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris priorto application, and prime the substrate (if applicable). 6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40°F and rising. NEMO ETC, LLC Evaluation Report M35710.12.10-1111 Certificote of Authorization #32455 a EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10 Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 5 of 8 6.4 I Citadel Plus: 6.4.1 Citadel Plus is limited to use as a Boral TileSealHT or GatorSeal. �NNEMOJetc- or mid -layer in multi -ply underlayment systems beneath Boral TileSeal 6.4.2 Slope limitations are those associated with the top -layer underlayment. 6.4.3 Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by X-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area, minimum 2 inches (horizontal lap) and minimum V end (vertical) laps. Install final underlayment layer atop Citadel Plus per 'direct-to-decK instructions for Boral TileSeal 50"r, Boral TileSealln, Boral MetalSeaF or GatorSeal. 6.4.4 To Base Sheet: Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part of a multi -ply system. Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and Section 6.4.3. Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50w, Boral TileSeal n or GatorSeal. Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. 6.5 BorafTileSeal50HT: 6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.5.2 Do not use Boral TileSeal 50"r on roof pitches less than 2:12. 6.5.3 Non -Tile Applications. Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by''/< -inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails &tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 24-inch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEMO ETC, LLC Evaluation Report M35710.12.10-R31 Certificate DfAuthom&Vti #32455 fire EDITION (20171 FBC NON-HVHZ EVALUATION FL14317-R10 Baml Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 6 of 8 ONEW10jetc. 6.5.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install Boral TileSeal 50' in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published installation instructions and Section 6.5.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.6 GatorSeal: 6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.6.2 Do not use GatorSeal on roof pitches less than 2:12. 6.6.3 Non -Tile applications. Direct to Deck: Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge, extending over by X-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions. 6.6.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.4. Install GatorSeal over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.6.3 except end (vertical) laps, described below. Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the granular top surface, rolling the interface into place with a weighted roller. 6.7 I .Boral TileSealHT orBoral MetalSeal"T: 6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.7.2 Do not use Boral TileSeaIHT or Boral MetalSealw on roof pitches less than 2:12. 6.7.3 Non -Tile Applications. Direct to Deck: For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into manageable lengths, typically 30 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller. Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch. Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral Roofing published installation instructions. NEMO ETC, LLC Evaluation Report M35710.12.10-R31 CerGfsote ofAuthorLwtion R32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R30 Boral Roof Undedayments; (602) 269-2288 Revision 11: 10/12/2019 Page 7 of 8 NNEMO I etc. 6.7.4 Non -Tile Applications, to Base Sheet: Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6A. Install Boral TileSeal"T or Boral MetalSeal"r over ASTM D226, Type 11 felt or Citadel Plus in accordance with Boral Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below. Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in contact with the fabric top surface, rolling the interface into place with a weighted roller. 6.7.5 Tile Applications: Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s), Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1. For adhesive -set tile applications, refer to Section 5.6.4 herein. Note: For adhesive -set tile systems, if there is abase ply or mid -ply of Citadel Plus in the system, the project design pressure requirements may not exceed -120 psf. Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeal'R or Boral MetalSeal"T with roof pitches of 2%to less than 3:12. Boral Roofing's Elevated Batten System or counter battens are required. As required bythe Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS ^ Brentwood, UL, LLC.—QUA9625; (631) 546-2458; - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report M35710AL10-R31 Cerdjicow ofAuihodwiion N32455 6v'EDITION (2017)FBC NON-HVHZ EVALUATION FL14317-RID Bor41 Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018 Page 8 of 8