EVALUATION REPORT BY
East Coast Metals, Inc. Evaluation Report €10240.08.0R-R4
FL5374-R4
2301 West 8 Lane
08
Hialeah, FL33010 Date oRevisi n 4: 03/17/2015
Revision 4: D3/17J2015
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for
use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described
herein have been evaluated for compliance with the 5th Edition (2014) Florida Building Code sections noted herein.
DESCRIPTION: East Coast Metals Channel Metals
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this
Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E- if the product changes or the
referenced Quality Assurance documentation changes. Trinity lERD requires a complete review of this Evaluation Report
relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words `TrinitylERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPI¢rnoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its
distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 7.
Prepared by:
Robertl.M. Nieminen, P.E.
Florida Registration No. 59.166, Florida DCA ANE1983
Thp faehnaasealaDPeasinywasaPliurv2tl tJ P.obm'%Iaminen,
P.E vn®/1TP-a15. GIs does no:se�sx asanelec:tenkabYsI.lh
FmduC Mmja ldn.r Id .th,e beensraiumJaetlsv;ha
Pmdutl Approval AdminitiR:m and sv :he named [Tien:
CERTIFICATION OF INDEPENDENCE:
1. Trinity] ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product
5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record far any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
ROOFING COMPONENT EVALUATION:
1.
2.
3.
4.
.! r `� 1-1-1
SCOPE:
Product Category: Roofing
Sub -Category: Roofing Accessories that are an Integral Part of the Roofing System
Compliance Statement: East Coast Metals Channel Metals, as produced by East Coast Metals, have demonstrated compliance
with the following sections of the Florida Building Code through testing in accordance with the following Standards. Compliance
is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein.
STANDARDS:
Section
Property
Standard
Year
1507.3.7
Installation,non-Ht7HZ
FRSA/TRI April 2012(04-12)
2012
3518.8.1
Installation, HVHZ
RA5118, 119&120
1995
1523.65.21
Static Uplift Resistanre
TAS 101
1995
171L21
Static Uprift Resistance
SBCO S51-D1.1
1997
REFERENCES.-
gnifty
Examination
Reference
Date
ERD(TST6049)
Static Uplift Resistance
E42730.08.3
08/23/2013
ERD UST60491
Static Uplift Resistance
ECNI-SC679512.14-1
02/27/2015
ERD(TST6049)
Static Uplift Resistance
EClvl-SC6795.12.14-2
02/27/2015
Florida TEC ITST7393)
TA5101
S30c2SR
10/27/2010
PRI (TST5878)
TA5101
ECM-001-02-01
09/21/2001
PRI (TST5878)
TAS101
ECNI-003-02-01
06/23/2008
PRI(TST5878)
TAS101
ECrri-004-02-01
05/13/2008
PRI(TS75878)
TAS 101
ECM-005-02-01
06/13/2009
PRI (TST5878)
TAS101
ECM-006-02-01
06/13/2008
PRI(TST5878)
TAS101
ECM-007-02-01
06/13/2009
PRI(TSTS878)
TA5101
ECM-008-02-01
06/13/1008
Florida Building Code
Attachment Requirements
FRSA/TRI April 2012(04-12)
0412032
Florida Building Code -HVHZ
Attachment Requirements
RA5118,119 and 120
1995
East Coast Metals
Metal Quality
Mill Certifications
Various
Architectural Testing(QUA1844)
Quality Control
Participation Letter
Exp.12/31/2018
PRODUCT DESCRIPTION:
4.1 Hip & Ridge Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved fODftlle adhesive.
Hip & Ridge Channel Metal is available in 119-3/8-inch (±
3/8-inch) length by 2-5, 3, 3.5, 4, 5, 6 or 7-inch L 3/8-inch)
heights with 1.5-inch (* 1/16-inch) deck -flanges.
Exterior Research and Design, LLC. Evaluation Report E10240.08.08-114
Certifimte afAutharfzodon #9303 F/1712015
Revision 4: 03/17/2015
Page 2 of 7
TRINITY ERD
4.2 Trim Lock Channel Metal: Pre -farmed metal channel
designed for use as a hip and ddge base to which roof tiles
are bonded in FBC Approved roof file adhesive. Trim Lock
Channel Metal Is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying tile adhesive.
Trim Lock Channel. Metal is available in 119-3/8-inch (+
3/8") length by 3, 3.5, 4, 5 or 6-inch (± 3/8-inch) heights
with 1.5-inch (±1/16-inch) deck -flanges.
4.2 Trim Lock Plus Channel Metal: Pre -formed metal channel
designed for use as a hip and ridge base to which roof tiles
are bonded in FBC Approved roof file adhesive. Trim Lock
Plus Channel Metal is characterized by its profiled and
perforated upper horizontal flange designed to receive
and allow for interlock with the overlying file adhesive
and its perforated deck flanges, designed for installation
atop the roof underlayment via placement in FBC
Approved roof tile adhesive, which flows -through and
interlocks with the underlying adhesive.
Trim Lock Plus Channel Metal is available in 119-3/8-inch
(±3/8") length by 3, 3.5, 4, 5 or 6-inch L3/8-inch) heights
with 1.5-inch (±1/164ncli) deck -flanges.
4.4 East Coast Metals Channel Metals are fabricated of the following metals:
➢ Galvanized Steel: Min, o.019±0.002-inch, ASTM A653 (G-90), min. 33 KSI.
i
➢ Galvalume Steel: Min. 0.019±0.002-inch, ASTM A792, AZ55, min. 35 KSI.
> Aluminum: Min. 0.032±0.002-inch, ASTM B209, 3003-N14, min. 21 KSI.
> Stainless Steel: Mirj. 0.019±0.002-Inch, A5TM A240/A480, T304, min. 35 KSI.
5. LIMrrwiciNs:
5.1 This is a building code evaluation. Neither Trinityl ERD nor Robert Nleminen, P.E. are, in any way, the Designer of
Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or
design guidance unless retained specifically for that purpose.
Exterior Research and Design, I.I.C.Evaluation Report E10240.08.08-R4
FL5374-R4
C&rificute ofauthoructiun 9950 Revision 4: 03/17/2015
Page 3 of 7
TRINITY ERD
5.2 FOR HVHZIURISDICrIONS:
5.2.1 For Hip & Ridge Channel Metal or Trim Lack Channel Metal, refer to FBC RAS 118, Drawing 13, Detail 3; RAS 119,
Drawing 12, Detail 3; or RAS 120, Drawing 15, Detail 3. For Trim Lock -Plus Channel Metal, refer to the installation
instructions herein.
5.2.2 For HVHZ jurisdictions, installations of Hip & Ridge Channel Metal and Trim Lock are prescriptive by RAS 118, 119 and
120, and the data in Tables IA and 1B is supplemental to these prescriptive allowances.
Installations of Trim Lock Plus are limited to projects having a required moment resistance (M,J or uplift resistance (F,),
as determined in accordance with RAS 127, not greater than the following values.
Referto the file adhesive manufacturer's published installation instructions for adhesive paddy placement details.
1'• "INDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in its own, single
foam paddy; file head laps are not bonded. This method is limited to 2-part tile adhesives. Allowable
performance data below for "INDEPENDENT" paddy placement already has a 2 to 1 margin of safety applied to
ultimate performance.
S "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the rile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT" paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
_ - TABLE SA: PERFORMANCE DuRTATIONs-HVHZ, INDEPENDENT PADOYPLACEMENT
-
(2TOIMAFGINOFSAFE ArRFADYAPPOEO)
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Design
Metal Type
Type
Placement
Moment
Moment Based
Uplift Based
(ft-lbf)
F' (Ibf)
Hip &Ridge
galvanized
clayar
3 Vi- 2-Component Foam
Independent
127
169
Channel Metal
concrete
Roof Tile Adhesive AN-160
Trim Lock
galvanized, Galvalume-,
day or
31101"' 2-Component Foam
Independent
171
159
aluminum or stainless steel
concrete
RoofTle Adhesive AH-160
Trim Lock Plus
galvanized, Galvalumea,
dayor
310'2-Component Foam
Independent
177
165
aluminum or stainless steel
concrete
Roof Tile Adhesive AH-160
_ TABLESB: PERFORMANCE LiMrrATION5-HVHZ, INTERDEPENDENT PADDY PLACEMENT - --
(4mI MARGIN OFSAFETYALRFApYAVIUM)
Hip/Ridge Metal
Tile
Adhesive
Allowable Performance
Moment Based
Uplift Based
Design
Metal Type
Type
Placement
MI(ft-Ibf)
F'(Ibf)
Trim Lock or Trim
galvanized, Galralumeo,
day or
3M"'2-Component Foam
Interdependent
95
88
Lock Plus
aluminum or stainless steel
Concrete
Roof Tile Adhesive AH-160
Trim Lock
galvanized, Galvalumeo,
day or
3M'" Roof Tile Adhesive
Interdependent
99
94
stainless steel
Concrete
RTA-1
Trim Lock
aluminum
day or
3M"' Foam Roof Tile
Interdependent
90
84
concrete
Adhesive RTA-1
Trim Lock Plus
galvanized, Galvalume",
day or
3M'" Foam Roof Tile
Interdependent
90
84
aluminum or stainless steel
Concrete
Adhesive RTA-1
galvanized, Galvalume-or
day or
TILE BOND'" Roof Tile
Trim Lack
stainlesssteel
Concrete
Adhesive
Interdependent
123
117
Trim Lock
aluminum
day or
TILE BOND" Roof Tile
Interdependent
79
73
Concrete
Adhesive
Trim Lock Plus
galvanized, Galvalume',
day or
TILE BOND"' Roof Tile
Interdependent
79
73
aluminum or stainless steel
concrete
Adhesive
galvanized, Galvalumee or
day or
Touch'n Seal StormBond
Trim Lock
stainless steel
concrete
Roof Tile Adhesive
Interdependent
146
139
Trim Lock
Aluminum
day or
Touch'n Seal StormBond
Interdependent
58
54
concrete
Roof The Adhesive
Trim Lock Plus
galvanized, Galvalume°,
day or
Touch'n Seal StormBond
interdependent
SB
54
aluminum or stainless steel
concrete
RoofTle Adhesive
Exterior Research and Design, LLG Evaluation Report E10240.08.08-114
Certifoote of Authoruation#9503 . FLS374•114
Revision 4:03/17/2015
Page 4 of 7
5.3 FOR NON-HV14Z JURISDICTIONS:
5.3.1 For Hip & Ridge Channel Metal or Trim Lock Channel Metal, refer to FRSA/TRI April 2012 (04-12). For Trim Lack Plus
Channel Metal, refer to the installation instructions herein
5.3.2 For non-HVHZ, installations are limited to projects having hip and ridge design pressure requirements, determined in
accordance with Table 1A of FRSA/TRI April 2012 (04-12), not greater than the following values. Refer to the tile
adhesive manufacturers published installation instructions for adhesive paddy placement details.
D "INDEPENDENT' paddy placement means each individual the is bonded to the Channel Metal in its own, single
foam paddy; tile head laps are not bonded. This method is limited to 2-part tile adhesives. This method is limited
to 2-part tile adhesives. Allowable performance data below for "INDEPENDENT' paddy placement already has a 2
to 1 margin of safety applied to ultimate performance.
➢ "INTERDEPENDENT" paddy placement means each individual tile is bonded to the Channel Metal in a foam paddy,
and a second foam paddy bonds the tile head lap, or two tiles are bonded to the Channel Metal using a single
foam paddy. Allowable performance data below for "INTERDEPENDENT' paddy placement already has a 4 to 1
margin of safety applied to ultimate performance.
TABLE 7A:. PERFORMANCE LIMrrATiON5—NON-HVHZ, INDEPENDENT PADDY PLACEMENT
(2 TO 1 MARGIN OFSAFETY ALRFADYAPPDED) .
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Psf)
Design
Metal Type
Type
Placement
Hip &Ridge
galvanized
day or
310-2-Component Foam Roof
Independent
169
Channel Metal
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalumea, aluminum or
clay or
3MTM 2-Component Foam Roof
Independent
173
stainless steel
concrete
Tile Adhesive AH-160
Trim Lock Plus
galvanized, Galvalume-, aluminum or
clay or
3M'"2-Component Foam Roof
Independent
178
stainless steel
concrete
Tile Adhesive AH-160
T ABLE 29: PERFoRMANu llmnAnoNs—NUN-HVHZ, fN omuENDENT PADDYPLACEMENT(4
TO 1 MARGIN OF5AFE7YALFMADYAPPDED)
Hip/Ridge Metal
Tile
Adhesive
Allowable Uplift
(Psf)
Design
Metal Type
Type
Placement
Trim Lock or-Frim
galvanized, Galvalume®, aluminum or
day or
3MTM 2-Component Foam Roof
Interdependent
98
Lock Plus
stainless steel
concrete
Tile Adhesive AH-160
Trim Lock
galvanized, Galvalume or stainless
day or
3MTM Foam Roof Tile Adhesive
Interdependent
ll0
steel
concrete
RTA-1
Trim Lock
aluminum
day or
3MTM Foam Roof Tile Adhesive
Interdependent
93
concrete
RTA-1
Trim Lock Plus
galvanized, Galvalume°, aluminum or
day or
3MTM Foam Roof Tile Adhesive
Interdependent
93
stainless steel
concrete
RTA-1
Trim Lock
galvanized.
nized. Galvalume' orstainless
clncrete
TILE BOND— Roof Tile Adhesive
Interdependent
152
Trim Lock
aluminum
day or
TILE BOND- Roof Tile Adhesive
Interdependent
82
concrete
Trim Lock Plus
galvanized, Galvalume-, aluminum or
day or
TILE BOND- Roof Tile Adhesive
Interdependent
82
stainless steel
concrete
Trim Lock
galvanized, Galvalume- orstainless
day or
Touch'n Seal StamnBond Roof
Interdependent
148
steel
concrete
Tile Adhesive
Trim Lock
Aluminum
day or
Touch'n Seal StormBond Roof
Interdependent
61
concrete
Tile Adhesive
Trim Lock Plus
Ea lvanized, Galvalume°, aluminum or
day or
Touch'n Seal StmmBond Roof
Interdependent
61
stainless steel
concrete
Tile Adhesive
Exterior Research and Design, LLC. Evaluation Report E10240.08.08-R4
c rtficae ofAurhorhadon d9503 FL5374-R4
Revision 4: 03/17/2015
_ _".._ __ . Page of7.
TRINFIN ERD
6. INSTALLATION: .
6.1 The roof deck shall be minimum 15/32-inch plywood (non-HVHZ) or minimum 19/32-inch plywood (HVHZ) attached in
accordance with FBC Chapter 23 to the satisfaction of the AHJ. "
6.2 Hip & Ridge Channel Metal and Trim Lock Channel Metal shall be installed using min. 11 ga. x 1Y-inch long z 3/9-inch
head diameter galvanized annular ring shank nails spaced 6-inch o.c. along both deck -flanges- Fasteners shall be
positioned Y-inch from the outside edge of each deck -flange, set in a bed plastic roof cement. For FBC HVHZ, refer to
FBC RA5119, Drawing 13, Detail 3; RAS 119, Drawing 12, Detail 3; or RA5120, Drawing 15, Detail 3.
6.3 Trim Lock Plus Channel Metal shall be installed atop the Approved roof underlayment in continuous 2-inch wide ribbons
of tile adhesive centered beneath each 1.5-inch wide deck flange. Place the Trim Lock Plus Channel Metal into the wet
adhesive and allow it to set-up prior to installation of roof tiles.
View of Polyset AH160 Placement for Trim Lack Plus Channel Metal Installation
63.1 It is critical that the bond between the Trim Lock Plus Channel Metal, the tile adhesive and the underlayment is not
disturbed prior to or during placement of the ridge tiles.
6.3.2 Approved underlayments are the codified '30/90' system or other FBC Approved roof underlayments listing approved
use of the subject tile adhesive.
Exterior Research and Design, I.I.C.Evaluation Report E10240.08.08-R4
[ertif ,ate ofAuthorizotian 99503 3117/2015
Revision 4: 03/17/20]5
Page 6 of 7
TRINW ERD
6.4 Tile shall be installed atop the Channel Metal in accordance with the the adhesive manufacturers Approved, published
installation instructions, subject to the limitations outlined in Section 5 herein. The exposed edges shall be packed and
pointed with Approved mortar or weather blocking adhesive in accordance with FRSA/TRI April 2012 (04-12) or RAS
118, RAS 119, RAS 120 requirements.
Hip / Ridge Tile
Tile Adhesive
Trim Lock Plus
Mortar or Weather Block
Adhesive
Tile Adhesive
View of Trim Lock Plus Channel Metal Installation after weather Blocked
6.4.1 Channel Metal shall be free of dust, debris, oils or other bond -breaking substance priorto placement of adhesive.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product.
B. MANUFACTURING PLANTS:
Contact the named CIA entity for manufacturing facilities covered by F.A.C. Rule 61G20-3 CIA requirements.
9. QUALITY ASSURANCE ENTITY:
Architectural Testing, Inc.—QUA1844T (717) 764-7700
- END OF EVALUATION REPORT -
Exterior Research and Design, LLc-
renl(Imm afAurhorhadon 495013
Evaluation Report E10240.08.08-R4
FL5374-R4
Revision 4:03/17/2015
Page 7 of 7
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certifimte of Authorization #9503
SCANNED 353 CHRISTIAN STREET, UNIT#13
_ TRINITYERD BY OXFORD, CT 06478
St. Lucie County (203) 262-9245
EVALUATION REPORT nPoseel
p°
Entegra Roof Tile, LLC
Imo' Evaluation Report E39310.11.11-1-R4
TEEGRA 1289 NE 9`s Avenue FL7804-R10
R O O F T I L C Okeechobee, FL 34972 Date of Issuance:12/02/2011
(602)515-6933 Revision 4: 10/17/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the 15" Edition (2017) Florida Building Code
(HVHZ) sections noted herein.
DESCRIPTION: Entegra Concrete Roof Tiles (HVHZ jurisdictions)
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the
referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change.
Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the
product changes or the referenced Quality Assurance documentation changes. TrinityiERD requires a complete
review of this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words 'Trinity) ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
The iaaimlk seal appearbi,.1au9hvrued by Robert Nkminen,
P.E. on 10117/2017. Thts does notserce as an dedp n oegy signed
document- Signed, sealed hardmples hate been t2nsmitled to the
Product Approval Administmtarand to the named dent
CERTIFICATION OF INDEPENDENCE:
1. Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither TrinitylERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
TRINITY ERD
ROOFING SYSTEM EVALUATION:
1. SCOPE:
Product Category: Roofing
Sub -Category: Roofing Tiles
Compliance Statement: Entegra Concrete Roof Tiles, as produced by Entegra Roof Tile, LLC, have demonstrated
compliance with the following sections of the Florida Building Code through testing in accordance with the following
Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth
herein.
2. STANDARDS:
Section
Pro a
Standard
Year
1523.6.5.2
Physical Properties
TAS 112
1995
1523.6.5.2
Wind Driven Rain
TAS 100
1995
1523.6.5.2.2
Static Uplift Resistance
TAS 101
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102
1995
1523.6.5.2.3
Static Uplift Resistance
TAS 102(A)
1995
3. REFERENCES:
KnottExamination
Reference
Date
ERD(TST6049)
TAS 101
P39740.02.12
02/21/2012
ATL(TST3782)
Physical Properties
RT0624.05-14
07/03/2014
ATL(TST3782)
Physical Properties
RT0624.04-14
07/07/2014
ATL(TST3782)
Physical Properties
RT1210.02-15
12/17/2015
ATL(TST3782)
Physical Properties
RT1210.03-15
12/17/2015
ATL (TST 3782)
Physical Properties
RT1103.01-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.02-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.03-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.04-15
11/07/2015
ATL (TST 3782)
Physical Properties
RT1103.05-15
11/07/2015
Miami-Dade(CER1592)
HVHZ Compliance
14-0416.12
11/27/2014
Miami-Dade(CER1592)
HVHZ Compliance
15-0721.04
11/05/2015
Miami-Dade(CER1592)
HVHZ Compliance
16-0112.06
02/2S/2016
Miami-Dade(CER1592)
HVHZ Compliance
16-0112.07
02/25/2016
Miami-Dade(CER1592)
HVHZCompliance
16-0112.08
02/25/2016
Tile Roof Institute
TAS 100, TAS 101, 102, 102(A)
Membership Confirmation
Current
PRI (QUA9110)
Quality Assurance
Service Confirmation
Exp. 11/02/2018
Exterior Research and Design, U.C.
Evaluation Report E39310.11.11-1-R4
Certifmte o)Authoriiution 0503
6r"EDITION(2017) F8CHVHZ EVALUATION
FL7804-R30
Entegra Roof Tiles
Revision 4:10/17/2017
Page 2 of 8
4. PRODUCT DESCRIPTION:
4.1 I TAS 112, Type 3a (flat-profile)`'-
2'
10,
Y
Bermuda Flat
Horizon Flat
�17-1/4"
TRINITY ERD
PIANTATIONFIAT.and HORIZON FIAT
Plantation Flat
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
Cenficote o)Authoruadon 09503 6TM EDITION(2017) FBC HVHZ EVALUATION FL7804-1110
Entegra Roof Tiles Revision 4: 10/17/2017
Page 3 of 8
4.2
TRINITY I ERD
rTAS'112, Type la (interlocking, -high -profile) „ I BELLA HIGH "S" -
Bella High "S"
4.3 1 TAS M. Twe lb (interlocking,.low=profile
4.3 1 TAS
17"
Estate "S"
Galena Spanish "S"
10"
"S" and HACIENDA
Hacienda
GALENA SPANISH "S" and REGAL
Regal
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
Cezuj7mre of Authorization M03 6r EDITION 12017) FBC HVHZ EVALUATION FL7804-1110
Entegra Roof Tiles Revision 4: 10/17/2017
Page 4 of 8
TRINITY' ERD
5. LIMITATIONS:
5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used- -
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is for use in FBC HVHZ jurisdictions or others adopting FBC HVHZ requirements.
5.3 Fire classification is not part of this evaluation; refer to FBC 1516 or listing by an approved testing agency for
fire rating of this product.
5.4 Reference is made to FBC 1512.4.2.4 regarding field testing of completed tile roof installations.
5.5 Applicant shall retain the services of an FBC listed, accredited laboratory to perform quarterly tests in
accordance with TAS 112, Appendix'A'.
5.6 Minimum underlayment shall comply with the RAS 118, RAS 119 or RAS 120, as applicable. Underlayment
products shall hold current Florida Statewide Product Approval or Local Approval for use in tile roof
assemblies in FBC HVHZ jurisdictions.
5.7 Minimum roof deck requirements shall be in accordance with applicable FBC HVHZ requirements.
5.8 All products in the roof assembly shall have quality assurance audit in accordance with the F.A.C. Rule
61G20-3.
6. INSTALLATION:
6.1 Entegra Concrete Roof Tiles may be mechanically fastened, mortar -set or adhesive -set. Installation shall
comply with manufacturer's current published instructions, but not less than the requirements of RAS 118,
RAS 119 or RAS 120, as applicable.
6.2 Attachment Calculations: Entegra Concrete Roof Tile shall be evaluated as a 'Moment -Based System' in
accordance with Roofing Application Standard RAS 127-11 using the data outlined herein.
•,TABLEI:AERODYNAMICMULTiPUERS-H.(FT3)' - - �- - -
Tile
Batten Application
Direct -Deck Application
Bermuda Flat
0.189
0.205
Plantation Flat
0.267
0.299
Horizon Flat
0.305
0.330
Bella High "5"
0.349
0.378
Estate "S"
0.267
0.289
Hacienda
0.267
0.289
Galena Spanish "S"
N/A
0.235
Regal
0.287
0.311
- TABLE 2: RESTORING MOMENT DUE TO GRAVITY a M. (FT -LBO)"
Roof Slope (0)
Tile
2:12<0<3:12
3:12<0<4:12
4:12<0<5:12
5:1250<6:12
6:12<0<7:12
0>7:12
Battens
I Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Battens
Direct
Bermuda Flat
5.22
6.43
5.17
6.37
5.09
6.27
4.98
6.15
4.86
6.00
4.72
5.83
Plantation Flat
7.22
7.91
6.85
7.79
6.75
7.67
6.61
7.52
6.44
7.32
6.26
7.04
Horizon
7.60
8.32
7.52
8.24
7.41
8.12
7.26
7.95
7.09
7.76
6.89
7.55
Bella High "S"
6.19
6.89
6.11
6.80
5.99
6.67
5.85
6.51
5.68
6.33
5.50
6.13
Estate "5"
6.14
6.84
5.91
6.74
5.82
6.64
5.70
6.50
5.56
6.33
5.40
6.14
Hacienda
5.92
6.80
5.92
6.80
5.82
6.61
5.70
6.55
5.56
6.39
5.41
6.22
Galena Spanish "5"
N/A
6.20
N/A
6.13
N/A
6.03
N/A
5.89
N/A
5.74
N/A
5.57
Regal
7.77
8.34
1 7.77
1 8.34
7.65
1 8.20
7.49
1 8.03
7.30 1
7.83
1 7.10 1
7.61
Exterior Research and Design, LLC Evaluation Report E39310.=11-1-R4
Certry7mte ofAuthodradon p9503 Ern EDITION (2017) FBC HVHZ EVALUATION FL7804-R30
____.. _.___.-.__-__Entegra Roof -Tiles __-_.____ _.__.__._.._..._.._.Revision 4:10/17/2017---- ___
Page 5 of a
TRINITY ERD
- TABLE 3A: ATTACHMENT RESISTANCE EXPRESSED AS A MOMENT- MF(FT-LBF) -
' - "- MECHANICALLY ATTACHED SYSTEMS
Tile
Fastener
Direct -Deck
(min. 15/32"
,plywood)
Direct -Deck
(min. 19/52"
plywood)
Battens
Type
#
Size
Shank
Clip
Nail
One (1)
10d
Smooth or Screw
N/A
73
9.8
4.9
Nail
Two (2)
10d
Smooth or Screw
N/A
14.0
18.8
7.4
Nail
One (1)
10d
Smoothor Screw
Eave
19.0
19.0
22.1
Nail
One (1)
10d
Smooth or Screw
Field
24.3
24.3
24.2
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
Bermuda Flat,
Plantation Flat or
Nail
Two (2)
SOd
Smooth or Screw
Field
35.5
35.5
34.8
Horizon
Nail
Two (2)
10d
Ring
N/A
30.9
38.1
17.2
Nail'
Two (2)'
10d'
Ring'
N/A
50.3'
65.5'
48.3'
Screw
One (1)
08
N/A
N/A
30.8
30.8
18.2
Screw
Two (2)
#8
N/A
N/A
51.7
51.7
24.4
' Installation with a 4-inch tile headlap and fasteners located min. 2Y,-inch from head of tile.
Nail
One(1)2
10d
Smoothor5crew
N/A
8.82
11.8,
4.1'
Nail
Two (2)
30d
Smooth or Screw
N/A
16.4
21.9
7.1
Nail
One (1)'
10d
Smoothor5crew,
Eave
19.0z
19.02
22.12
Nail
One (1)'
Sod
Smooth or Screw
Field
24.3'
24.32
24.22
Nail
Two (2)
10d
Smooth or Screw
Eave
31.9
31.9
32.2
Nail
Two (2)
10d
Smooth or Screw
Field
35.5
35.5
34.8
Estate "5" or Hacienda
Nail
Two (2)
lud
Ring
N/A
2T8
37.4
28.8
Nail'
Two (21'
1&
Ring'
N/A
43.0'
67-5'
S0.9,
Screw
One
#8
N/A
N/A
25.82
25.82
22.92
Screw
Two (2)
#8
N/A
N/A
47.1
47.1
49.1
'installation with a 4-Inch the headlap and fasteners located min, 2'A-inch from head of tile.
' For one (1) fastener installations, utilize hole that is approximately 4Y inch from the interlocking edge.
Nail
One (1)
10d
Smoothor5crew
N/A
5.1
6.8
2.8
Nail
TWO (2)
10d
Smooth orScrew
N/A
6.9
9.2
7.3
Nail
One (1)
10d
Smooth or Screw
Field
23.1
23.1
29.0
Nail
One (1)
SOd
Smoothor5crew
Eave
29.3
29.3
24.0
Nail
Two (2)
30d
Smooth or Screw
Field
27.6
27.6
38.6
Bella High "S", Galena
"S"
Nail
Two (2)
10d
Smooth or Screw
Eave
38.1
38.1
41.8
Spanish or Regal
Nall
Two (21
30d
Ring
N/A
28.6
41.2
19.4
Nall'
Two (2),
10d'
Ring'
N/A
33.1'
48.1'
50.9'
Screw
One (1)
#8
N/A
N/A
20.7
20.7
18.1
Screw
Two (2)
08
N/A
N/A
43.2
43.2
29.8
' Installation with a 4-inch tile headlap and fasteners located min. 2%4nch from head of tile.
Exterior Research and Design, I.I.C. Evaluation Report E39310.11.11-1-R4
Certificate o/Authorizodon#95o3 6m EDITION(2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 6 of 8
TRINITY i ERD
TABLE4: ATrACHMENT RESISTANCE EXPRESSED AS A MOMENT— MF(Fr-IBF) _
MORTAR AND ADHESIVE -SET SYSTEMS
Nate fromEntegra Roof Tile, LLC.: The performance data listed in Table 4-are based on the respective adhesive manufacturers' test,
reports and Miami -Dade NOAs. Entegra Roof rile, LLC. relies upon: the adhesive manufacturers to provide these: values for our inclusion
in this FBC HVHZ Evaluation Report. Please. consul the individual adhesive manufacturer for information on productapprovals,_
limitations, revisions or other information for determining wind load and overturning moment performance..- - : -
Tile Adhesive
Tile
Product
Product Approval
Placement
Mf(ft-lbf)
'TILE BOND'"" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
41
Bermuda
'Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
73
Flat,
•'Polyset® RTA-1" by ICP Adhesives& Sealants
NOA 16-0315.03
Interdependent (2-paddy)
52
Plantation
Fiat or
Horizon
"Polyset® AH-160" by ICP Adhesives & Sealants
NOA 17-0322.03
Interdependent (2-paddy)
43
Independent (medium paddy, `30 g)
51
Independent (large paddy, -45 g)
92
'TILE BOND'"" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
44
'Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
42
"5"
"Polyset° RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
44
Estate or
Hacienda
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA 17-0322.03
Interdependent(2-paddy)
50
Independent (medium paddy, -30 g)
37
Independent (large paddy,'"54 g)
61
Mortar
Various
Per RAS 120
21
'TILE BOND'"" by Dow Chemical
NOA 16-0222.01
Interdependent (2-paddy)
48
'Touch N' Seal Storm Bond" by DAP Foam
NOA 16-0421.03
Interdependent (2-paddy)
52
Bella High
"S",
"Polyset® RTA-1" by ICP Adhesives & Sealants
NOA 16-0315.03
Interdependent (2-paddy)
36
Galena
Spanish "S"
or Regal
"Polyset® AH-160" by ICP Adhesives &
Sealants
NOA17-0322.03
Interdependent (2-paddy)
30
(medium paddy,-30 g)
49
-Independent
Independent (large paddy,-63 g)
94
Mortar
Various
Per RAS 120
25
7. LABELING:
7.1 Each unit shall bear the imprint and/or identifiable marking of the manufacturer's name or logo, as detailed
below. Tile lots shall be labeled in accordance with the requirements of the Accredited Quality Assurance
Agency noted herein.
and/or
ENTEURR Q��
Labeling: Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S"
Exterior Research and Design, U.C. Evaluation Report E39310.11.11-1-R4
CertllaneofAutft dwion#9503 OEDITION(2017) FBC HVHZ EVALUATION FL7804-R10
Entegra Roof Tiles Revision 4:10/17/2017
Page 7 of 8
TRINITY; ERD
and/or
Hanson
Labeling: Horizon Flat, Hacienda, Regal
8. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
9. MANUFACTURING PLANTS:
Plant- "- „- . _-
Profiles' -'
Okeechobee, FL
Bermuda Flat, Plantation Flat, Estate "S", Bella High "S", Galena Spanish "S'
Ft. Myers, FL
Horizon Flat, Hacienda
Deerfield Beach, FL
Horizon Flat, Hacienda, Regal
10. QUALITY ASSURANCE ENTITY:
PRI Construction Materials Technologies, I.I.C. — QUA9110; (813) 621-5777
- END OF EVALUATION REPORT —
Exterior Research and Design, U.C. Evaluation Report E39310.11.11.1-R4
certifimte ofAuthortradon 49503 6r" EDrnON(2017) FBC HVHZ EVALUATION FL7904-R30
Entegru Roof TIIes Revision 4! 10/17/2017
Page 8 of 8
RECEIVED
APR 0 4 2010
Permitting Departm4nr �EOREIC#�.
St. Lucie County
Certificate of Authorization #32455
SCANNED 353 Christian Street, Unit#13
BY Oxford, CT 06478
to St. Lucie County (203) 262-9245
ENGINEER EVALUATE TEST CONSULT CERTIFY
O.
Boral Roofing Evaluation Report M35730.12.30-R11
7575 Irvine Center Drive, Suite 100 FL14317-R30
Irvine, CA. 92618
(602)269-2288
Date of Issuance: 12/21/2010
Revision 11:10/22/2018
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product underthe Florida Building Code and Florida Building Code, Residential Volume. The products
described herein have been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted
herein.
DESCRIPTION: Boral Roof Underlayments
LAeEUNG: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the
product(s), the Quality Assurance or the production facility location(s). NEMO ETC, LLC requires a complete review of
this Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMOietc. Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 8.
Prepared by:
„"Y "^•,.,,--
Robert J.M. Nieminen, P.E.
'.''.:.•�s P `f T::
s�s�*•ti _a�;i j.`,•'
the facsimile seal appearing was authorized by Robert
Florida Registration No. 59166, Florida DC4 ANE1983
Nieminen,P.E on 10/12/2011L This does not serve as an
'
electronically signed document.
CERnRCATION OF INDEPENDENCE:
1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
NNEMOletc.
ROOFING COMPONENT EVALUATION:
-1. SCOPE
Product Category:
Roofing
Sub -Category:
Underlayment
Compliance Statement:
Boral Roof Underlayments,
as marketed by Boral Roofing,
have demonstrated
compliance with the following sections of the 6t6 Edition (2017) Florida Building Code through testing in
accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations
/ Conditions of Use set forth herein.
STANDARDS:2.
Section
Pro a
Standard
Year
1504.3.1
Wind Uplift
UL 1897
2012
1507.1.1, T1507.1.1,
Physical Properties
ASTM D1970
2015
1507.2.9.2 _
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
Entity
Examination
Reference
Date
ERD (TST 6049)
Physical Properties
M36790.07.11
09/30/2011
ERD (TST 6049)
Physical Properties
B40380.08.12
08/28/2012
ERD M 6049)
Tensile Adhesion / LTA
C41420.09.12-2
09/11/2012
ERD (TST 6049)
Adhesion
B41940.09.12
09/13/2012
ERD (TST 6049)
Tensile Adhesion / LTA
B47390.07.14-1
07/31/2014
ERD (TST 6049)
Tensile Adhesion / LTA
B47390.09.14
09/04/2014
OC (PDM1638)
Physical Properties
Equivalency statement
11/02/2017
PRI (TST 5878)
ASTM D1970
NEI-031-02-02:REV
10/27/2010
PRI (TST 5878)
ASTM D1970
NEI-029-02-01:REV
12/03/2010
PRI (TST 5878)
Tensile Adhesion / LTA
NEI-046-02-01REV
12/17/2010
PRI(TST 5878)
FRSA/TRI April 2012
NEI-076-02-01
02/14/2011
PRI (TST5878)
ASTM D1970
NEI-034-02-02
01/29/2013
PRI (TST 5878)
Wind Uplift
BORR-001-02-01
03/17/2015
PRI (TST 5878)
Wind Uplift
BORR-005-02-01
06/24/2015
PRI (TST 5878)
Tensile Adhesion / LTA
DAPF-002-02-01
03/08/2018
PRI (TST 5878)
ASTM D1970 (adhesion)
OCF-443-02-01
10/11/2018
UL, U.C. (QUA 9625)
Quality Assurance
Service Confirmation
Exp. 08/21/2020
4.1 BoralO TileSeal 50"T is a nominal 50-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D3970.
4.2 BoralO TileSealHT is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.3, BoralO MetalSealHT is a nominal 60-mil thick, polyester -surfaced, self -adhering SBS modified bitumen roof
underlayment; meets ASTM D1970 and FRSA/TRI 04-12.
4.4 GatorSeal® is a nominal 55-mil thick, granular -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roof underlayment; meets ASTM D1970.
4.5 Citadel® Plus is a nominal 48-mil thick, fabric -surfaced, fiberglass reinforced, self -adhering SBS modified bitumen
roofing underlayment for use as a base -layer in multi -ply underlayment systems; meets ASTM D1970.
NEMO ETC, LLC Evaluation Report M35710.12.104122
Cerdjirare of Author&atron#32455 a EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-RIO
Bard[ Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 2 of 8
NNEm'oletc.
5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in anyway, the Designer
of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting —
or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Laboratory Report; refer to current Approved Roofing Materials Directory for
fire ratings of this product.
5.4 Boral Roof Underlayments may be used with any prepared roof coverwhere the product is specifically referenced
within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for
approval based on this evaluation combined with supporting data for the prepared roof covering.
5.5 Allowable Roof Covers: Table 1 pertains to use of each listed underlayment by -itself beneath the stated roof
covers. Refer to the installation instructions for multi -ply underlayment options.
ROOF COVEROPTIONS
Underlayment
Asphalt
Nail -On Tile
Adhesive -set
Metal
Wood Shakes
Slate
Shingles
rile
&Shingles
Boral TileSeal Sow
Yes
No
No
Yes
Yes
Yes
Boral TileSealm
Yes
Yes
Yes
yes
Yes
Yes
(See 5.5.1)
Boral MetalSealw
Yes
Yes
Yes
Yes
Yes
Yes
(See 5.5.1)
GatorSeal
Yes
No
No
No
Yes
Yes
5.5.1 "Adhesive -set Tile" is limited to use of following Approved tile adhesives / underlayment combinations.
Adhesive
Florida Product
Approval
Underlayments
DAP Foam Touch'n Seal Storm Band Roof Tile Adhesive
FL14506
Boral TileSealw or Boral MetaLSealw
DAP Foam Touch'n Seal StormBond 2 Two -Component
Polyurethane Roof Tile Adhesive
FL21374
Boral TileSeal"' or Baral MetalSealw
Dow TILE BONDTM Roof Tile Adhesive
FL22525
Boral TileSeal"' or Boral MetalSealw
ICP Adhesives Polyset® AH-160
FL6332
Boral TileSeal"' or Boral MetalSealw
ICP Adhesives Polyset® RTA-1
FL6276
Boral TileSealw` or Boral MetalSealw
t Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance.
NEMO ETC, LLC Evaluation Report M35710.12-70-R31
Certiftwie ofAuthorizadon n32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R30
Boral Roof Underlayments: (602) 269.2288 Revision 11: 10/121201S
Page 3 of 8
NNEW10letc.
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Citadel Plus, Boral TileSeal 50"T, Boral TileSeal"T, Boral MetalSeal"T or GatorSeal:
➢ Plywood (unprimed or primed with ASTM D41 primer).
Boral TileSealHT or Boral MetalSealw:
➢ OSB (unprimed or primed with ASTM D41 primer).
Note: Refer to Section 5.6.4 for uplift limitations associated with direct -deck underlayment installations where the
overlying roof cover is adhesive -set file roofing
5.6.2 Bond to Base Laver Underlavment:
Citadel Plus, Boral TileSeal 5011T, Boral TileSealn Boral MetalSealHr or GatorSeal:
➢ ASTM D226, Type II felt; Citadel Plus.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum
codified requirements. For installations under adhesive -set tile systems, base layer shall be attached per minimum
requirements of FRSA/TRI April 2012 (04-12), Appendix A, Table 1, or as listed in Section 5.6.4 herein, or as tested
in accordance with FBC 1504.3.1.
5.6.3 Bond to Other Substrate Types:
Citadel Plus, Boral TileSeal 5011; Boral TileSeal"T, Boral MetalSeal"T or GatorSeal:
➢ ASTM D41 primed metal (e.g., flashing metal, valley metal, etc.).
Boral TileSealHT:
➢ Huber Zip Deck (unprimed or primed with ASTM D41 primer); Dens Deck Prime.
Note: For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturer's Product Approval.
5.6A Wind Resistance for Underlavment Systems in Adhesive -set Tile Applications: FRSA/TRI April 2012 (04-12) does
not address wind uplift resistance of all underlayment systems beneath adhesive -set tile systems, where the
underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems
that are not addressed in FRSA/TRI April 2012 (04-12) and are used in adhesive -set tile applications. Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the
ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer
to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads
#1 Maximum Design Pressure = -120.0 post;
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: (Optional) ASTM D41 to the plywood deck
Base Ply: Citadel Plus, self -adhered
Cap Sheet: Boral TileSeal"T or Boral MetalSealln, self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 3Y<" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
#2 Maximum Design Pressure = -242.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Base Ply: None
Cap Sheet: Boral TileSealw or Boral MetalSeal"T, self -adhered and back -nailed within the selvedge -edge side laps
using 12 ga. x IY4" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
NEMO ETC, LLC Evaluation Report M35710.12.10-R11
certfmte ofAuthormation R32455 6r" EDITION (2017) FBC NON.HVHZ EVALUATION FL14317-R30
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2028
Page 4 of 8
*NEMOletc.
#3 Maximum Design Pressure=-202.5 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Tropical Roofing Products #410 Quick Dry Primer or other ASTM D41 primer to the plywood deck
Base Ply: None
Cap Sheet: BoralTileSeal"TorBoral MetalSeal"n self -adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 3Y." ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
#4 Maximum Design Pressure=-210.0 psf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: KARNAK #89 Sta-Tak Primer to the plywood deck
Base Ply: None
Cap Sheet: Boral TileSeal"TorBoral MetalSealHr,self-adhered, and back -nailed within the selvedge -edge side laps
using 12 ga. x 1Y" ring shank nails through 32 ga.,1-5/8" diameter tin caps spaced 12-inch o.c.
#5 Maximum Design Pressure=-120.0 psf:
Deck: Min. 2,500 psi structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: ASTM D41 to the concrete deck
Base Ply: (Optional) Citadel Plus, self -adhered
Cap Sheet: Boral TileSealw or Boral MetalSeal"T, self -adhered
5.6.4.1 Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
5.7 Exposure Limitations:
GatorSeal shall not be left exposed for longer than 30-days after installation, priorto placement of final roof cover.
Boral TileSeal SO" ; Boral TIIeSealw or Boral MetalSealw shall not be left exposed for longer than 180-days after
installation, prior to placement of final roof cover.
Citadel Plus, for use as a base -layer in a multi -ply underlayment system, shall not be left exposed for longer than
180-days after installation, prior to placement of subsequent underlayment layer.
5.8 Tile Slippage Limitations fFRSA/TRI April 2012 (04-12)1:
When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as
follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles.
FORDIREcT-DEcK TILE INSTALLATIONS
Underlayment
Tile Profile Staging Method
Maximum Slope
Boral TileSeal` or
Boral MetalSealw
atMax. 30-tile stack
6:12
Lugged Max. 30-tile stack
6:12
6.1 Boral Roof Underlayments shall be installed in accordance with Boral Roofing published installation instructions
subject to the Limitations set forth in Section 5 herein and the specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to
remove any dust and debris priorto application, and prime the substrate (if applicable).
6.3 Install self -adhering underlayment when ambient and surface temperatures are minimum 40°F and rising.
NEMO ETC, LLC Evaluation Report M35710.12.10-1111
Certificote of Authorization #32455 a EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R10
Boral Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 5 of 8
6.4 I Citadel Plus:
6.4.1 Citadel Plus is limited to use as a
Boral TileSealHT or GatorSeal.
�NNEMOJetc-
or mid -layer in multi -ply underlayment systems beneath Boral TileSeal
6.4.2 Slope limitations are those associated with the top -layer underlayment.
6.4.3 Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by X-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the top edge of the sheet to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch
diameter plastic or steel cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the
black -selvedge area, minimum 2 inches (horizontal lap) and minimum V end (vertical) laps.
Install final underlayment layer atop Citadel Plus per 'direct-to-decK instructions for Boral TileSeal 50"r, Boral
TileSealln, Boral MetalSeaF or GatorSeal.
6.4.4 To Base Sheet:
Install base sheet of ASTM D226, Type II felt in accordance with Code requirements or install base ply of Citadel
Plus in accordance with Boral Roofing published installation instructions and Section 6.4.3 and when used as part
of a multi -ply system.
Install optional Citadel Plus as a mid -ply in accordance with Boral Roofing published installation instructions and
Section 6.4.3.
Install final underlayment layer atop Citadel Plus per 'direct -to -deck' instructions for Boral TileSeal 50w, Boral
TileSeal n or GatorSeal.
Note: For adhesive -set tile systems, if there is a base ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
6.5 BorafTileSeal50HT:
6.5.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.5.2 Do not use Boral TileSeal 50"r on roof pitches less than 2:12.
6.5.3 Non -Tile Applications. Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by''/< -inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails &tin -tags or 1-inch diameter
plastic or steel cap nails spaced maximum 24-inch o.c. for slopes below 7:12 and maximum 12-inch o.c. for slopes
7:12 and greater. Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch.
Seal under end (vertical) laps using approved mastic, or use Joined and Folded Seam or Inverted Sheet Seam
method detailed in Boral Roofing published installation instructions.
NEMO ETC, LLC Evaluation Report M35710.12.10-R31
Certificate DfAuthom&Vti #32455 fire EDITION (20171 FBC NON-HVHZ EVALUATION FL14317-R10
Baml Roof Underlayments; (602) 269-2288 Revision 11: 10/12/2018
Page 6 of 8
ONEW10jetc.
6.5.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type 11 felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install Boral TileSeal 50' in accordance over ASTM D226, Type II felt or Citadel Plus with Boral Roofing published
installation instructions and Section 6.5.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.6 GatorSeal:
6.6.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.6.2 Do not use GatorSeal on roof pitches less than 2:12.
6.6.3 Non -Tile applications. Direct to Deck:
Cut the membrane into manageable lengths, typically 10 to 12 ft. Align the membrane parallel to the roof edge,
extending over by X-inch. Fold the membrane away from the edge onto itself. Remove the release sheet. Place
the membrane with the exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with
a weighted roller.
Fasten the black selvedge edge to the deck with corrosion resistant roofing nails, nails & tin -tags or 1-inch diameter
plastic or steel cap nails spaced 24-inch o.c. for slopes below 7:12 and 12-inch o.c. for slopes 7:12 and greater.
Overlap successive courses the entire width of the black -selvedge area, minimum 3-inch.
Seal end (vertical) laps using SBS Mastic under all side (vertical) laps or any other laps where the self -adhering
bituminous underside is in contact with the granular or mineral top surface, rolling the interface into place with a
weighted roller, or using the Inverted Sheet Seam detailed in Boral Roofing published installation instructions.
6.6.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6.4.
Install GatorSeal over ASTM D226, Type II felt or Citadel Plus in accordance with Boral Roofing published installation
instructions and Section 6.6.3 except end (vertical) laps, described below.
Apply SBS Mastic under all side (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the granular top surface, rolling the interface into place with a weighted roller.
6.7 I .Boral TileSealHT orBoral MetalSeal"T:
6.7.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for
the type of prepared roof covering to be installed.
6.7.2 Do not use Boral TileSeaIHT or Boral MetalSealw on roof pitches less than 2:12.
6.7.3 Non -Tile Applications. Direct to Deck:
For OSB substrate, prime with ASTM D41 primer and allow to dry prior to installation. Cut the membrane into
manageable lengths, typically 30 to 12 ft. Align the membrane parallel to the roof edge, extending over by %-inch.
Fold the membrane away from the edge onto itself. Remove the release sheet. Place the membrane with the
exposed rubberized asphalt onto the deck, pressing firmly into place. Roll into place with a weighted roller.
Fasten the black selvedge edge to the deck with roofing nails, nails & tin -tags or 1-inch diameter plastic or steel
cap nails spaced maximum 12-inch o.c. Overlap successive courses the entire width of the black -selvedge area,
minimum 3-inch.
Seal under all end (vertical) laps using approved mastic or use Inverted Sheet Seam method detailed in Boral
Roofing published installation instructions.
NEMO ETC, LLC Evaluation Report M35710.12.10-R31
CerGfsote ofAuthorLwtion R32455 6" EDITION (2017) FBC NON-HVHZ EVALUATION FL14317-R30
Boral Roof Undedayments; (602) 269-2288 Revision 11: 10/12/2019
Page 7 of 8
NNEMO I etc.
6.7.4 Non -Tile Applications, to Base Sheet:
Install ASTM D226, Type II felt in accordance with Code requirements or install Citadel Plus in accordance with
Boral Roofing published installation instructions and Section 6A.
Install Boral TileSeal"T or Boral MetalSeal"r over ASTM D226, Type 11 felt or Citadel Plus in accordance with Boral
Roofing published installation instructions and Section 6.7.3, except end (vertical) laps, described below.
Apply SBS Mastic under all end (vertical) laps or any other laps where the self -adhering bituminous underside is in
contact with the fabric top surface, rolling the interface into place with a weighted roller.
6.7.5 Tile Applications:
Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions
noted above as a guideline.
For mechanically fastened tile roofing over 2-ply system, consisting of Base Sheet and self -adhering top sheet(s),
Base Sheet fastening shall be not less than FRSA/TRI April 2012 (04-12), Table 1.
For adhesive -set tile applications, refer to Section 5.6.4 herein.
Note: For adhesive -set tile systems, if there is abase ply or mid -ply of Citadel Plus in the system, the project design
pressure requirements may not exceed -120 psf.
Refer to Section 5.8 for tile staging limitations. Battens must be used for all tile installations atop Boral TileSeal'R
or Boral MetalSeal"T with roof pitches of 2%to less than 3:12. Boral Roofing's Elevated Batten System or counter
battens are required.
As required bythe Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS ^
Brentwood,
UL, LLC.—QUA9625; (631) 546-2458;
- END OF EVALUATION REPORT -