Loading...
HomeMy WebLinkAboutPLANSJ -r Applicable Codex Regulations, and Standards 1. The 611a Edition (2017) Florida Building Code, specifically Chapter 16 Structural Design, Chapter 20 Aluminum, and Chapter 23 Wood. 2. AA ASM 35 and Specifications for Aluminum Structures, Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association, Inc. Washington, D.C., 2010 Edition and the Guide to Aluminum Construction in high wind areas, 2010. 3. ASCE 7-10. Loading Criteria 1. Live Load: 10 PSF per 6th Edition (2017) Florida Building Code, Appendix I Section 105.1 2. Dead Load: 2 PSF 3. Wind Load: 3.1. Building Occupancy Category, Section 1604.5 and Table 1604.5; Risk Category 1. 3.2. Basic Wind Speed, Figure 1609.3(1), State of Florida lebrisRegion&Basic Wind Speed, Section 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed: Vera = 160 -MPH = 124 MPH 3.3. Exposure Category, Section 1609.4.3: Exposure B 4. Building Category for Aluminum Structures, Section 2002.6: Category Type 2 - Glass Room: Non -Habitable, Unconditioned RoofType 1. Roof Type; Gable 2. Roof Material: Existing 3" Structall Composite Panel. Foundation Design Existing roncrete slab. No additional concrete footing or slab is remdred to resist the loads Imposed upon the existing slab by the proposed construction if the existing slab Is a minimum pro" thick and in sound condition. free from structural cracking. stallion. or other deterioration Specifications The following specifications are applicable to this project: 1. All work shall be in accordance with the 6th Edition (2017) Florida Building Code, and any other applicable local codes and regulations. 2. Aluminum extrusions shall be 6005 TS Alloy. Due to quality control issues, no manufacturer substitution is acceptable without the specific written, signed and sealed authorization of Florida Aluminum Engineering, Inc. 3. Fasteners are required to be corrosion resistant; minimum SAE Grade 2 or better zinc prated to ASTM B633, or coated stainless steel series "300, or uncoated stainless steel series "400". 4. All Selflsfating Beam Sections are m be stitched with either #14 screws 6" from ends and 24" center to censer or #12 screws 6" from ends and 12" center to center. 5. Door location shall be determined by contractor in the field. 6: Where concrete specifications are required, whether in the screen enclosure scope or not, by one or more regulatory agency, the following specifications are applicable: a. Concrete shall conform to ASTM C94 for the following components: I. Portland Cement Type 1,- ASTM C 150 ii. Aggregates - Large Aggregate 314" max - ASTM C 33 HL AG entraining +1-1%-ASTMC 260 iv. Water reducing agent- ASTMC 494 v. Clean Potable water vi. Other admixtures not permitted b. Metal accessories shall conform to: I. Reinforcing Bars- ASTM A615, grade 60 ii. Welded wire fabric - ASTM A185 c. Concrete slump at discharge chute not less than 3" ormore than 5". Water added after hatching is not permitted. d. Prepare and place concrete per American Concrete Institute Manual of Standard Prmticq Parts 1, 2, and 3 including hot weather recmmnendations. e. Moist core or polyethylene curing permitted. f. Prior to placing concrete, treat the entire subsurface area for termites in compliance with the NBC. g. Concrete shall be placed over a polyethylene vapor barrier. IL All aluminum components embedded within concrete shall be coated with a bituminous paint or epoxy. 7. All lumber and plywood shall have grade marks and treatment identification and Shall conform to the following: a. Framing lumber shall be minimum no. 2 southern yellow pine and have a maximum moisture content of 15% b. Pressure treatments shall be osmoxalts, osmose k-33, womansalts or celcure, as recommended for the use condition. Pressure treated lumber shall be impregnated with a cea salt treatment in accordance with fs. tt-w-571 and bear the American Wood Preservatives Institute quality mark Ip-2 c. Wall Sheathing: APA rated Sheathing, thickness as indicated, Exposure 1. d. Aluminum members that are uncoated shall be separated from PT lumber by 30# felt paper, 10 mil polyethylene sheet or equivalent material. 8. Contractor shall provide Florida Product Approval information as In the exact window being utilized for dais project, including manufacturers specifications, and installation methods for anchoring the submitted windows to Aluminum members and specific sins as indicated on A-1. 9. Contractor shall provide any additional backing (aluminum, wood etc..) and anchors as required by the window manufacturers recommended procedures. 10. All glass panels within 24" of a door opening shall be oftempcmd glass per FBC-R308.4 11. All flashing and weatherpmofrng shall be provided by the contractor. 12. Use of these plans acknowledges and accepts a limit of liability not to exceed design and engineering fee. WIND SPEED AND EXPOSURE HAVE BEEN DETERMINED USING THE ADVANCED TECHNOLOGY COUNCIL'S WEBSITE AND GOOGLE EARTH. 4X4XO.125 Q REVIEWED FOR RODE COMPLIANCE RT. LUCIE/C/'OUNTY BOCC 2X6SMB l4TH WALL / END BEAM 2X6SMB 2X9SMB EDGE BEAM RIDGE BEAM w w Oa Oa �o No w 0 0 o 0 n n 2X3 END BEAM ALUMINUM KICKPLATE BELOW WINDOWS (TYP) ALL EXISTING FRAMING TO REMAIN COMPONENTS &CLADDING DESIGN PRESSURES FOR WINDOWS / DOORS: +30.4 PSF / -40.7 PSF 16'-0" 4X4XO.125 4X4XO. 5'-9" 5'-9" 4'-6" :Z o O l~/1 Z � '.� 2X3GIRT 4X4XO.125 L_ (TYP) POST 2X6SMB 2X3GIRT 'EDGE BEAM (�) �I X3XO.093 a POST 2XDJ o 2XDJ ra X3XO.0931 POST o 1X2(TYP) a °pax 4X4XO.125 PO ST 8"-0" --] 19 oq- oi13 ST.LtiCIECOiTNTY%LDDOrtr �i01 REVIENYED FOR SIAtiCE VINYL SIDIMHFaY9bW WINDOWS (icrATE PLANS AIN PERTSIT NNST BE KEPT ON JOB w :NS?'ACTION WILL BE 4LaDE- _4X4XO.125 I POST a I ba SCANNED BY St. Lucie County FILE H- VI � W O d' U � O FQ~ LU U O N OLU V y 1 m In O Qc2 0 n.l-�aLL DRAWN BY TP 03/22/19 SHEET NO: A-1