Loading...
HomeMy WebLinkAboutENGINEERING LETTERENGINEERING & TESTING, INC. Phone: (866) 781-6889 •Fax: (866) 784-8550 www.floridaengineeringandtestin.g.com 250 S.W.13th Avenue SCANNED _ -- — Pompano Beach, FL 33069 BY DATE: 4/1/19 St. Lucie CoUlltyJOB ORDER #: 19-1605 CLIENT: All Area Roofing ADDRESS: 3921 S. US Highway 1 Fort Pierce, Florida 34982 PROJECT: Leonis Residence 5V Crimp 26 Ga. Steel Roof Panels ADDRESS: 1835 Golden Ponds Drive Fort Pierce, FL 34945 2017 FBC/ASCE-7 DESIGN PRESSURE CALCULATIONS Proiect Information: Mean Height = Max. 15' Exposure: C Basic/Ultimate Wind Speed: V it=170 mph Length = 52' Category: H Nominal Wind Speed: Vasd=V it*40.6 Width = 25' Slope: 3/12 =14' (asd = allowable strength design) Parapet Wall: N/A Residential Kz = 0.85, Kzt = 1.0, Kd = 0.85 Design Calculations: Velocity Pressure: q = 0.00256*Kj<ztKdV2 Velocity Pressure (it): q=0.00256(0.85)(1.0)(0.85)(170)2] = 53.45 psf Velocity Pressure (asd): q=0.00256(0.85)(1.0)(0.85)(170*40.6)2] = 32.07 psf Width of Pressure Coefficient: 0.1(25') 0.4(15') Effective Wind Area: <10ft2 External Pressure Coefficient: 1) GCP1 = -0.9 2) GCP2 = -1.7 3) GCP3 = -2.6 Design Pressures Based on Vasd: = 2.5' = 6.0' ) use: 3'0" Internal Pressure Coefficient: 1) GCPi = 0.18 1) Field Pl = 32.07*[(-0.9) — (0.18)] = -34.6 psf 2) Perimeter P2 = 32.07* [(- 1.7) — (0.18)] = -60.3 psf 3) Corners P3 = 32.07*[(-2.6) — (0.18)] = -89.2 psf rig IV Q Quality A, ✓Lssurance r Page 2, 4/1//19, Job Orde',. _J-1605 All Area Roofing Leonis Residence - 5V Crimp 26 Ga. Steel Roof Panels 1835 Golden Ponds Drive; Fort Pierce, Florida: Attacbment Requirements: Based on the requirements of Florida Product Approval # 11651.12R3 with maximum design pressures of-108.5psf and-156.5psf; the following are our recommended fastening patterns to attach the 24" wide 5V Crimp 26 ga. Steel Roof Panels to the minimum 15/32" thick plywood or wood deck with # 9-15 X 1-1/2" Hex -Washer Head wood screws to penetrate 1/4" min. thru deck (or sufficient length to meet requirements): Fastener Pattern at Panel Ribs; 12"o.c. in all roof zones acceptable per approved Florida Product Approval provided. Notes: Corners and perimeter (edge, hip, & ridge) area dimension shall not be less than a = 3'0" (Zone 2: Perimeter (including along ridges) is a 3'0" wide strip, Zone 3: Corners are 3'0" x 3'011) Contractor to verify that the fastening patterns meet manufacturer's requirements for issuance of a warranty (as applicable). All work shall be in compliance with the local building code product control notice of acceptance and manufacturer specifications and Florida Building Code 2017 Edition. Wind load calculations based on ASCE-7, 2017 FBC, and information provided by client. Client is responsible for verifying existing conditions as it pertains to the above provided product approval. All work shall be inspected by our field engineer (or authorized representative) or a building department inspector to verify compliance with specifications. Sincerely, ��Ulll�l Mark A. MMRgo, P.E. Florida En ffxQgmA test Florida Re 4§20oF Certificate oi. 1MW&,atWn ;'"It Et4G"—,I` A�/lllllll�� �F