HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online - Page 1 of 2
SCANNED ,��
rc
n k BY uE
*t St. Lucie County
parr
Bas Nome 191n I User Registretlan Hot Topics Submit Surcharge I statsa Fags I P-lelf-bes CsntaG us BOS site Map UPRs seamh
dba
'YI �1' Product Approval
lsr USER: Public User
PmNrtt nonm . Me's PrM -n or Ann mron Srur > Arrke ion I ist > Applleaeon Oetall
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name Who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced Standard and Year (of Standard)
FL5259-R28
Revision
2017
Approved
POLYGLASS USA
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1330 Ext 242
malpert@pclyglass.com
Maury Alpert
malpert@polyglass.com
Maury Alpert
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(912) 429-8610
MAlpert@polyglass.com
Arlel Lender
1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954)233-1230
ALender@polyglass.com
Roofing
Underlayments
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report- Hardcopy Received
Robert Nleminen
PE-59166
UL LLC
09/13/2021
John W. Knezevich, PE
:qi Validation Checklist- Hardcopy Received
FL5259 R28 COI 2018 01 COI NIEMINEN df
Standard
Year
ASTM D1970
2015
ASTM D226
2009
ASTM D4798
2011
ASTM D6164
2011
ASTM D6222
2011
FM 4474
2011
FRSA/TRI April 2012
2012
UL 1897
2012
m-i5
http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZn3 Cr... 12/19/2018
Florida Building Code Online
Page 2 of 2
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
01/24/2018
01/29/2018
01/30/2018
04/10/2018
FL it
Model, Number or Name
Description
5259.1
Polyglass Roof
Roofing underlayments
Underlayments
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL5259 R26 11 2016 01 FINAL ER POLYGLASS UNDERLAYMENT FL525
Approved for use outside HVHZ: Yes
R28.ndf
Impact Resistant: N/A
Verified By: Robert Nieminen PE-59166
Design Pressure: +N/A/-622.5
Created by Independent Third Party: Yes
Other: 1.) The design pressure In this
Evaluation Reports
application relates to one particular
underlayment system (over concrete deck)
FL5259 R28 AE 2018 01 FINAL R POLYGLA S UNDERLAYMENTS FL S9
R28.I df
for use under foam -on tile systems (where
Created by Independent Third Party; Yes
the underlayment forms part of the load -
path). Refer to ER Section 5.6.4 For other
systems, other deck types and associated
maximum design pressures. 2.) Refer to ER
Section 5 for other limits of use.
once Neel
QlMast Us a U91 Xa rSun Read, T,11theiswe H 32399 Phone' 1150-4e1a824
The State of Florida H an AA/EEO employer-CaevriaM 2007-2013 state of Florid :: Pdvaeu statement ;; Access0ilty statement:; pecan Stasement
Florida law, email addresses art pubit paeords. ifyou do not want your a -mall address released In msponse to a publk-reconls request, do hot send ale
I this entity. Instead, conlad the O ies by phone or by traditional mall. if you have any questions, please mntad 950.492. 1395.'Purmant W Setllon 4:
Irlda Statutes, effective odOber 1, 2012, licensees Ikenmd under Chapter 455, F.S. mud provide the Department with an email address a they, have on
prwlded may be used for pllldal mmmunlotlon with Me Ummee. However Small addresses am public remrd. If you do net wish to supply a personal a
t PmvNe the Dap o melt with an email add.. which ran be made avnllabla W Me publio To determine If you am a licensee under chapter 455, F.S., f
dirk here,.
Produat Approval Accapti:
SCCUTII}'AILTItICS
http://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZ,n3 Cr... 12/19/2018
Florida Building Code Online
Page 1 of 5
SCANNED
BY
°
St. Lucie County
far
BLS Home I Lag In User Rep6tratlon
HOL TOpIGi Submit surcharye Sta[s®Facts Publlcatlons FRC StdR I. BQa Slte Map �. Unks I SearrA
Floda�
t Product Approval
l0 d3
d
r
� USER: Public User
Pmduc[ AnomvA Menu > pmduc[ er Anolirarwn
SeamM1 > Aeellra°Idn Uri > Appllcatlon petal)
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
�/ Vt
Archived
❑ v
Product Manufacturer
Gulf Coast Supply & Manufacturing, U.C.
Address/Phone/Email
4020 S. W. 449th Street
Horseshoe Beach, FL 32648
(352) 498-0778
Info@gulfcoastsupply.com
Authorized Signature
Ray Bowen
Info@gulfcoastsupply. cam
Technical Representative
David Eng _
Address/Phone/Email
14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352) 498-0778
Info@gulfmastsupply.oam
Quality Assurance Representative
David Eng
Address/Phone/Email
14429 SW 2nd PI
Ste G30
Newberry, FL 32669
(352)498-0778
david.eng@gulfcoastsupply.com
Category
Roofing
Subcategory
Metal Roofing
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Daniel S. Kuhn
the Evaluation Report
Florida License PE-75519
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/12/2024
Validated By Locke Bowden P.E.
Wi Validation Checklist - Hardcopy Received
Certificate of Independence FLI 1651 R3 COI Cert of Independence 2017-10-09.pdf
Referenced Standard and Year (of Standard) Standard Year
FM 4471
1992
TAS 100
1995
TAS 110
2000
TAS 125
2003
UL 1897
2012
UL 580
2006
https://floridabuilding.org/pr/pr_app_dfl.aspx?param=wGEVXQwtDgsQFc5Kd/o2ffrZeCS... 3/20/2018
Florida Building Code Online
Page 2 of 5
Equivalence of Product Standards
Certified By
Sections From the Code
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Go to Page = a
Method 1 Option D
10/10/2017
10/12/2017
10/17/2017
12/12/2017
00 Pagel/200
FL tf
Model, Number or Name
Description
11651.1
0.032" Aluminum SV Crimp
Min 0.032° 5 V Crimp Aluminum Roof Panel over 15132"
Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -108.5 psf @ 12" O.C. Install per manufacturers
details. Not for use in HVHZ Zones.
Installation Instructions
FL11651 R3 11 FL11651 1 R3 Metal ROOF Panel Detail -
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Parry: Yes
Evaluation Reports
F111651 R3 AE FI 11651 1 R3 032SyC S-
3ZPlvwood NgnHVHZ-signed odf
Created by Independent Third Party: Yes
11651.2
0.032° Aluminum Gulf Lok
Min 0.032" Aluminum Gulf Lok 16- Wide Roof Panel over
15/32° Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.GPSF
Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0
psf @ 5 3/16" o.c. fastener spacing. Install per
manufacturers details. Not for use In HVHZ Zones.
Installation Instructions
FL11651 R3 11 FL11651 2 R3 Metal Roof Panel Detail -
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AF F111651 2 R3 032GulfLak 16 1
32Plywogd Nonl-[VHZ-stQned.pdF
Created by Independent Third Party: Yes
11651.3
1" 24ga. Gulf Snap
1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32"
Plywood
Limits of Use
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/--131.OPS
Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use in
HVHZ Zones.
Installation Instructions
FL11651 R3 If FL11651 3 R3 Metal Roof Panel Detail -
slgned.ndf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AF Fl-1165I 3 R3 1 24G Ifs o 17 IS-
32Plvwgnd HVHZ-s'aned ndf
Created by Independent Third Party: Yes
11651.4
1" 24ga. Versal-oc
1" Versal-oc 24ga 16.5" Wide Roof Panel over I5/32"
Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-138.5PSF
Other: -71 psf @ 24° o.c. dip spacing. -138.5 psf @ 6" o.c.
clip spacing. Install per manufacturers details. For use In
HVHZ Zones.
Installation Instructions
FL11651 R3 it FL11651 4 R3 Metal Roof Panel Detail -
signed.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Parry: Yes
Evaluation Reports
FL11651 R3 AE FL11651 4 R3 24jLerEgLocSR I6 IS
32Plvwood HVHZ-signedodf
Created by Independent Third Party: Yes
11651.5
1" Versal-oc .032" Aluminum
I" Versal-oc min .032" Aluminum over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-SOI.OPSF
Installation Instructions
FLI 1651 113 11 FL11651 5 R3 Metal Rggr Panel Detail -
sioned.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Parry: Yes
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs"c5Kb/o2frrZeCS... 3/20/2018
Florida Building Code Online
Page 3 of 5
Other: -63.3 psf @ 24" o.c. dip spacing, -101.0 psf @ 6"
o.c. clip spacing. Install per manufacturers details. For. use
In HVHZ Zones.
Evaluation Reports
FL11651 R3 AE FL11651 5 R3 I'n 032VersaLoc
SR 16 15-32PI d HVHZ-slon d odf
Created by Independent Third Party: Yes
11651.6
1.5° 24ga. Gulf Snap
1.5" Gulf Snap 24ga. 16" Wide Roof Panel over I5/32"
_
.Plywood- -
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-116.0PSF
Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. dip spacing. -116.0 psf @ 6" o.c. clip spacing. Install
per manufacturers detals. For use in HVHZ Zones.
FL11651 R3 11 FL11651 6 R3 Metal Roof Panel Detail -
sianed.Ddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 6 R3 1.5 24GuIf5 ao 16 IS -
32Plvwood HVHZ-sinned ndf
Created by Independent Third Party: Yes
11651.7
1.5" 24ga. Versal-oc
1.5" Versal-oc min 24ga. 16" wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-123.5PSF
Other: -59.75 psf @ 24" O.C. clip spacing. -123.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. For use
In HVHZ Zones.
FL11651 R3 Il FL11651 7 R3 Metal Roof Panel Detail -
sianed.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 IS -
32PIvwood HVHZ-signed.vdf
Created by Independent Third Party: Yes
11651.8
2" 24ga. Megal-oc
Min 24 Ga. 2" Megal-oc 18" wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.5PSF
Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
o.c. clip spacing. Install per manufacturers details. Not for
use In HVHZ Zones.
FL11651 R3 H FL11651 8 R3 Metal Roof Panel Detall-
sianed.Ddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FLI1651 R3 AE FL11651 8 R3 24VersaLoc 16 IS -
32PI ood N HVHZ-sla ed odf
Created by Independent Third Party: Yes
11651.9
24 Ga. Gulf Lok
Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-96.7PSF
Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76
psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8"
fastener spacing. -161 psf @ 5-1/8° fastener spacing. Install
per manufacturers details. Not for use in HVHZ Zones.
FL11651 R3 11 FL1I6S1 9 R3 Metal Roof Panel Detail -
signed.odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 9 R3 24Gulf-ok 16 IS -
32PIvwo d NonHVHZ-sianed.DdF
Created by Independent Third Party: Yes
11651.10
24 Ga. Gulf Seam
Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood
Purlins over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-93.SPSF
Other: -93.5 psf @ 18" o.c. Install per manufacturers
details. Not for use in HVHZ Zones.
FL11651 R3 11 FL11651 10 R3 Metal Roof Panel Detail -
sioned.udf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 10 R3 24GuIf5eam 16 1 4 IS-
32Plvwaod NonHVHZ-sinned odf
Created by Independent Third Party: Yes
11651.11
24 Ga. Gulf Seam
Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof
Panel over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-108.SPSF
Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12"
spacing. Install per manufacturers details. Not for
use In H Z Zones.
FL11651 R3 11 FL11651 11 R3 Metal Roof Panel Detail -
soned.ndf
Verified By: Dan Kuhn, P.E. 7S519
Created by Independent Third Party: Yes
Evaluation Reports
FLI1651 R3 AE FL11651 11 R3 24G IfSe IS 1 -
32Plvwood NcnHVHZ-sianed.Ddf
Created by Independent Third Party: Yes
1165 ,12j
26 Ga. 5V Crlmp
Min 26 Ga. SV Crimp Roof Panel over 15/32" Plywood
https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K"/`2frrZeCS... 3/20/2018
Florida Building Code Online
Page 4 of 5
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.SPSF
Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf
@ 6' D.C. fastener spacing. Install per manufacturers details.
For use In HVHZ Zones.
Installation Instructions
FL11651 R3 11 FL11652 17 R3 Metal Roof Panel Detail -
sianed.sdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL31651 R3 AE FL11651 12 R3_265 C im IS -
32Plvwood HVHZ-sinned Ddf
Created by Independent Third Party: Yes
11651.13
26 Ga. SV Crimp
Min 26 Ga. 5V Crimp over 15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131.PSF
Other: -94.25 psf @ 16" o.c, fastener pattern. -131.0 psf
@ 16" D.C. fastener pattern. Install per manufacturers
details. Not for use in HVHZ Zones.
FL11651 R3 11 FL11651 13 R3 Metal Roof Panel Detall-
signed.DdF
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 13 R3 265 C imo 15-
32Plvwood NonHVHZ-signed Ddf
Created by Independent Third Party: Yes
11651.14
26 Ga. 5V Crimp
Min 26 Ga. SV Crimp Roof Panel over 1x4 Wood Purlins over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-156.SPSF
Other: -108.5 psf @ 12" D.C. fastener spacing. -156.5 psf
@ 6" D.C. fastener spacing. Install per manufacturers details.
For use in HVHZ Zones.
FL11651 R3 11 FL11651 14 R3 Metal Roof Panel D t 1
skmed.Ddf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 14 R3 265 C Im 1 4 15
32Plvwood NonHVHZ-signed odf
Created by Independent Third Party: Yes
11651.15
26 Ga. Gulf Lek
Min 26 Ga. Gulf Lek 16" Wide Roof Panel over 15/3Z"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-361.OPSF
Other: -63.5 psf @ 5 3/16' D.C. fastener spacing.-121.75
psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16' D.C. fastener
spacing. Install per manufacturers details. For use In HVHZ
Zones.
FL11651 R3 It FL11651 15 R3 Metal Roof Panel D t II -
sioned.sdf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 15 R3 26Cuifl-k 16 15-
32Plvwood HVHZ-sioned odf
Created by Independent Third Party: Yes
11651.16
26 Ga. Gulf Lek
Min 26 Ga. Gulf Lek 16' Wide Roof Panel over 15/32"
Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL11651 R3 11 FL11651 16 R3 Metal Roof Panel DeL&
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-63.5PSF
Other: -63.5 psf @ 5 3/16' ox. fastener spacing.-121.75
psF @ 5 3/16' fastener spacing. -161 psf @ 5 3/16" fastener
spacing. Install per manufacturers details. Not for use In
HVHZ Zones.
sianed.ndF
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FU 1651 R3 AE FL11651 16 R3 76CUIrL k 16 15-
32Plvwood NonHVHZ-signed.sdf
1 Created by Independent Third Party: Yes
11651.17
26 Ga. GuIFPBR
Min 26 Ga. Gulf PBR Roof Panel over 15/32' Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant'. N/A
Design Pressure: +N/A/-154.7PSF
Other: -59.25 psf @ 24" D.C. fastener pattern.-154.75 psf
@ 12" D.C. fastener pattern. Install per manufacturer details.
Not for use in HVHZ
F111651 R3 II FL11651 17 R3 Metal Roof Panel DgL4L
sianed.odF
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 17 R3 26GuIFPBR 15-
32Plvwood NonHVHZ-sioned odf
Created by Independent Third Party: Yes
11651.18
26 Ga. GUIfPBR
Min 26 Ga. GulfPBR Roof Panel over Ix4 Wood Pudins over
15/32" Plywood
Limits of Use
Installation Instructions
Approved for use in HVHZ: Yes
FL11651 R3 IT FL11651 18 R3 Metal Roof Panel Detail-
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-151.7PSF
Other: -100.5 psf @ 24" D.C. fastener spacing.-151.75 psf
@ 12' fastener spacing. Install per manufacturers details.
For use in HVHZ Zones
sioned.ndf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 IS R3 26GUIFPBR 1 4 15-
32PIywood HVHZ-Sig ed Ddf
Created by Independent Third Party: Yes
https://floridabuilding.org/Pr/pr_app_dtl.aspx?param=wGEVXQWtDgsQFc5KD/`2frrZeCS... 3/20/2018
Florida Building Code Online
Page 5 of 5
11651.19 126 Ga. GuIfPBR
Min 26 Ga. GuIfPBR over 15/32" Plywood
Limits of Use
Approved for use in HVHZ: Yes
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design_ Pressure:+N/A/-154.7PSF
Other: -60.5 psf @ 24" o.c. Fastener spacing.-154.75 psf
@ 12" o.c. fastener spacing. Install per manufacturer's
details. For use In HVHZ Zones.
Installation Instructions
FL11651 R3 11 FL11651 19 R3 Metal Roof Panel Det '1-
slaned.odF
Verified By: Dan Kuhn, P.E. 75519
CreatedbyIndependent Third Party: Yes
Evaluation Reports
FLI1651 R3 AE FL11651 19 R3 26G IFPBR 15-
32Plvwood HVHZ-signed,DdF
Created by Independent Third Parry: Yes
11651.20
26 Ga. GUVPBR
Min 26 Ga. GuIfPBR over 10 Wood Purlins over 15/32"
Plywood
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-151.7PSF
Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75 psf
@ 12" fastener spacing. Install per manufacturer's details.
Not for use in HVHZ Zones
Installation Instructions
FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail -
signetl odf
Verified By: Dan Kuhn, P.E. 75519
Created by Independent Third Party: Yes
Evaluation Reports
FL11651 R3 AE FL11651 20 R3 26GuIFPBR 1 4 IS -
32Plvwood NonHVHZ-staned.odf
Created by Independent Third Party: Yes
Go to Page u tip
Back Wert
00Page l/200
$gntapL Inc :: 2fiel Blair to d, Tlifthalaau R 323n Phone: 8504e2-I824
The State of Florida is an A41M employer. Cpoyddht 2007-2013 Stateof Ronda:: Edvacvstatement:: Ameaslb0ity Statement:: Refund statement
Under Florida low, email addresses are public mmrds. If you do not want your a -mall address released in response to a publlCme,vos request, do not send
electronic mall to this antler. Instead, contact Me office by phone or by traditional mall. If you have any questions, please cented 850.487.1395. •Pursuant to
section 455.275F3J. Florida statutes, effective October 1, 2012, licensees Seamed under chapter 455, F.S. must provide Me Department with an email address it
they have one. The mays provided may be used for oRtlal communimelon with Me romea. However mall addresses are public record. If you do not wish to
Supply a personal address, Please provide Me Department with an email address whIsh can be made available M Me publk. To determine if you am a licensee under
Chapter 455, F.S., please elicit here .
product Approval Accepts:
FW
•e r
SCCUrl1}'AIETIIICS'