Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code Online - Page 1 of 2 SCANNED ,�� rc n k BY uE *t St. Lucie County parr Bas Nome 191n I User Registretlan Hot Topics Submit Surcharge I statsa Fags I P-lelf-bes CsntaG us BOS site Map UPRs seamh dba 'YI �1' Product Approval lsr USER: Public User PmNrtt nonm . Me's PrM -n or Ann mron Srur > Arrke ion I ist > Applleaeon Oetall FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method Florida Engineer or Architect Name Who developed the Evaluation Report Florida License Quality Assurance Entity Quality Assurance Contract Expiration Date Validated By Certificate of Independence Referenced Standard and Year (of Standard) FL5259-R28 Revision 2017 Approved POLYGLASS USA 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1330 Ext 242 malpert@pclyglass.com Maury Alpert malpert@polyglass.com Maury Alpert 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (912) 429-8610 MAlpert@polyglass.com Arlel Lender 1111 W. Newport Center Drive Deerfield Beach, FL 33442 (954)233-1230 ALender@polyglass.com Roofing Underlayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report- Hardcopy Received Robert Nleminen PE-59166 UL LLC 09/13/2021 John W. Knezevich, PE :qi Validation Checklist- Hardcopy Received FL5259 R28 COI 2018 01 COI NIEMINEN df Standard Year ASTM D1970 2015 ASTM D226 2009 ASTM D4798 2011 ASTM D6164 2011 ASTM D6222 2011 FM 4474 2011 FRSA/TRI April 2012 2012 UL 1897 2012 m-i5 http://www.floridabuilding.org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZn3 Cr... 12/19/2018 Florida Building Code Online Page 2 of 2 Equivalence of Product Standards Certified By Sections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 01/24/2018 01/29/2018 01/30/2018 04/10/2018 FL it Model, Number or Name Description 5259.1 Polyglass Roof Roofing underlayments Underlayments Limits of Use Installation Instructions Approved for use In HVHZ: No FL5259 R26 11 2016 01 FINAL ER POLYGLASS UNDERLAYMENT FL525 Approved for use outside HVHZ: Yes R28.ndf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: +N/A/-622.5 Created by Independent Third Party: Yes Other: 1.) The design pressure In this Evaluation Reports application relates to one particular underlayment system (over concrete deck) FL5259 R28 AE 2018 01 FINAL R POLYGLA S UNDERLAYMENTS FL S9 R28.I df for use under foam -on tile systems (where Created by Independent Third Party; Yes the underlayment forms part of the load - path). Refer to ER Section 5.6.4 For other systems, other deck types and associated maximum design pressures. 2.) Refer to ER Section 5 for other limits of use. once Neel QlMast Us a U91 Xa rSun Read, T,11theiswe H 32399 Phone' 1150-4e1a824 The State of Florida H an AA/EEO employer-CaevriaM 2007-2013 state of Florid :: Pdvaeu statement ;; Access0ilty statement:; pecan Stasement Florida law, email addresses art pubit paeords. ifyou do not want your a -mall address released In msponse to a publk-reconls request, do hot send ale I this entity. Instead, conlad the O ies by phone or by traditional mall. if you have any questions, please mntad 950.492. 1395.'Purmant W Setllon 4: Irlda Statutes, effective odOber 1, 2012, licensees Ikenmd under Chapter 455, F.S. mud provide the Department with an email address a they, have on prwlded may be used for pllldal mmmunlotlon with Me Ummee. However Small addresses am public remrd. If you do net wish to supply a personal a t PmvNe the Dap o melt with an email add.. which ran be made avnllabla W Me publio To determine If you am a licensee under chapter 455, F.S., f dirk here,. Produat Approval Accapti: SCCUTII}'AILTItICS http://www.floridabuilding. org/prlpr_app_dtl.aspx?param=wGEVXQwtDgvbSgAaZ,n3 Cr... 12/19/2018 Florida Building Code Online Page 1 of 5 SCANNED BY ° St. Lucie County far BLS Home I Lag In User Rep6tratlon HOL TOpIGi Submit surcharye Sta[s®Facts Publlcatlons FRC StdR I. BQa Slte Map �. Unks I SearrA Floda� t Product Approval l0 d3 d r � USER: Public User Pmduc[ AnomvA Menu > pmduc[ er Anolirarwn SeamM1 > Aeellra°Idn Uri > Appllcatlon petal) Application Type Revision Code Version 2017 Application Status Approved Comments �/ Vt Archived ❑ v Product Manufacturer Gulf Coast Supply & Manufacturing, U.C. Address/Phone/Email 4020 S. W. 449th Street Horseshoe Beach, FL 32648 (352) 498-0778 Info@gulfcoastsupply.com Authorized Signature Ray Bowen Info@gulfcoastsupply. cam Technical Representative David Eng _ Address/Phone/Email 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352) 498-0778 Info@gulfmastsupply.oam Quality Assurance Representative David Eng Address/Phone/Email 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 david.eng@gulfcoastsupply.com Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ❑ Evaluation Report- Hardcopy Received Florida Engineer or Architect Name who developed Daniel S. Kuhn the Evaluation Report Florida License PE-75519 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden P.E. Wi Validation Checklist - Hardcopy Received Certificate of Independence FLI 1651 R3 COI Cert of Independence 2017-10-09.pdf Referenced Standard and Year (of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 580 2006 https://floridabuilding.org/pr/pr_app_dfl.aspx?param=wGEVXQwtDgsQFc5Kd/o2ffrZeCS... 3/20/2018 Florida Building Code Online Page 2 of 5 Equivalence of Product Standards Certified By Sections From the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Go to Page = a Method 1 Option D 10/10/2017 10/12/2017 10/17/2017 12/12/2017 00 Pagel/200 FL tf Model, Number or Name Description 11651.1 0.032" Aluminum SV Crimp Min 0.032° 5 V Crimp Aluminum Roof Panel over 15132" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -108.5 psf @ 12" O.C. Install per manufacturers details. Not for use in HVHZ Zones. Installation Instructions FL11651 R3 11 FL11651 1 R3 Metal ROOF Panel Detail - sioned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Parry: Yes Evaluation Reports F111651 R3 AE FI 11651 1 R3 032SyC S- 3ZPlvwood NgnHVHZ-signed odf Created by Independent Third Party: Yes 11651.2 0.032° Aluminum Gulf Lok Min 0.032" Aluminum Gulf Lok 16- Wide Roof Panel over 15/32° Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.GPSF Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf @ 5 3/16" o.c. fastener spacing. Install per manufacturers details. Not for use In HVHZ Zones. Installation Instructions FL11651 R3 11 FL11651 2 R3 Metal Roof Panel Detail - sioned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AF F111651 2 R3 032GulfLak 16 1 32Plywogd Nonl-[VHZ-stQned.pdF Created by Independent Third Party: Yes 11651.3 1" 24ga. Gulf Snap 1" Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/--131.OPS Other: -67.3 psf @ 24" o.c. clip spacing. -131 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use in HVHZ Zones. Installation Instructions FL11651 R3 If FL11651 3 R3 Metal Roof Panel Detail - slgned.ndf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AF Fl-1165I 3 R3 1 24G Ifs o 17 IS- 32Plvwgnd HVHZ-s'aned ndf Created by Independent Third Party: Yes 11651.4 1" 24ga. Versal-oc 1" Versal-oc 24ga 16.5" Wide Roof Panel over I5/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.5PSF Other: -71 psf @ 24° o.c. dip spacing. -138.5 psf @ 6" o.c. clip spacing. Install per manufacturers details. For use In HVHZ Zones. Installation Instructions FL11651 R3 it FL11651 4 R3 Metal Roof Panel Detail - signed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Parry: Yes Evaluation Reports FL11651 R3 AE FL11651 4 R3 24jLerEgLocSR I6 IS 32Plvwood HVHZ-signedodf Created by Independent Third Party: Yes 11651.5 1" Versal-oc .032" Aluminum I" Versal-oc min .032" Aluminum over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-SOI.OPSF Installation Instructions FLI 1651 113 11 FL11651 5 R3 Metal Rggr Panel Detail - sioned.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Parry: Yes https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgs"c5Kb/o2frrZeCS... 3/20/2018 Florida Building Code Online Page 3 of 5 Other: -63.3 psf @ 24" o.c. dip spacing, -101.0 psf @ 6" o.c. clip spacing. Install per manufacturers details. For. use In HVHZ Zones. Evaluation Reports FL11651 R3 AE FL11651 5 R3 I'n 032VersaLoc SR 16 15-32PI d HVHZ-slon d odf Created by Independent Third Party: Yes 11651.6 1.5° 24ga. Gulf Snap 1.5" Gulf Snap 24ga. 16" Wide Roof Panel over I5/32" _ .Plywood- - Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-116.0PSF Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. dip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per manufacturers detals. For use in HVHZ Zones. FL11651 R3 11 FL11651 6 R3 Metal Roof Panel Detail - sianed.Ddf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 6 R3 1.5 24GuIf5 ao 16 IS - 32Plvwood HVHZ-sinned ndf Created by Independent Third Party: Yes 11651.7 1.5" 24ga. Versal-oc 1.5" Versal-oc min 24ga. 16" wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-123.5PSF Other: -59.75 psf @ 24" O.C. clip spacing. -123.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. For use In HVHZ Zones. FL11651 R3 Il FL11651 7 R3 Metal Roof Panel Detail - sianed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 7 R3 1.5 24VersaLoc 16 IS - 32PIvwood HVHZ-signed.vdf Created by Independent Third Party: Yes 11651.8 2" 24ga. Megal-oc Min 24 Ga. 2" Megal-oc 18" wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.5PSF Other: -71.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" o.c. clip spacing. Install per manufacturers details. Not for use In HVHZ Zones. FL11651 R3 H FL11651 8 R3 Metal Roof Panel Detall- sianed.Ddf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FLI1651 R3 AE FL11651 8 R3 24VersaLoc 16 IS - 32PI ood N HVHZ-sla ed odf Created by Independent Third Party: Yes 11651.9 24 Ga. Gulf Lok Min 24 Ga. Gulf Lok 16" Wide over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-96.7PSF Other: -81.75 psf @ 10-1/4" o.c. fastener spacing. -96.76 psf @ 5-1/8" o.c. fastener spacing.-121.75 psf @ 5-1/8" fastener spacing. -161 psf @ 5-1/8° fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. FL11651 R3 11 FL1I6S1 9 R3 Metal Roof Panel Detail - signed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 9 R3 24Gulf-ok 16 IS - 32PIvwo d NonHVHZ-sianed.DdF Created by Independent Third Party: Yes 11651.10 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.SPSF Other: -93.5 psf @ 18" o.c. Install per manufacturers details. Not for use in HVHZ Zones. FL11651 R3 11 FL11651 10 R3 Metal Roof Panel Detail - sioned.udf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 10 R3 24GuIf5eam 16 1 4 IS- 32Plvwaod NonHVHZ-sinned odf Created by Independent Third Party: Yes 11651.11 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use In HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-108.SPSF Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" spacing. Install per manufacturers details. Not for use In H Z Zones. FL11651 R3 11 FL11651 11 R3 Metal Roof Panel Detail - soned.ndf Verified By: Dan Kuhn, P.E. 7S519 Created by Independent Third Party: Yes Evaluation Reports FLI1651 R3 AE FL11651 11 R3 24G IfSe IS 1 - 32Plvwood NcnHVHZ-sianed.Ddf Created by Independent Third Party: Yes 1165 ,12j 26 Ga. 5V Crlmp Min 26 Ga. SV Crimp Roof Panel over 15/32" Plywood https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K"/`2frrZeCS... 3/20/2018 Florida Building Code Online Page 4 of 5 Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.SPSF Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ 6' D.C. fastener spacing. Install per manufacturers details. For use In HVHZ Zones. Installation Instructions FL11651 R3 11 FL11652 17 R3 Metal Roof Panel Detail - sianed.sdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL31651 R3 AE FL11651 12 R3_265 C im IS - 32Plvwood HVHZ-sinned Ddf Created by Independent Third Party: Yes 11651.13 26 Ga. SV Crimp Min 26 Ga. 5V Crimp over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-131.PSF Other: -94.25 psf @ 16" o.c, fastener pattern. -131.0 psf @ 16" D.C. fastener pattern. Install per manufacturers details. Not for use in HVHZ Zones. FL11651 R3 11 FL11651 13 R3 Metal Roof Panel Detall- signed.DdF Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 13 R3 265 C imo 15- 32Plvwood NonHVHZ-signed Ddf Created by Independent Third Party: Yes 11651.14 26 Ga. 5V Crimp Min 26 Ga. SV Crimp Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-156.SPSF Other: -108.5 psf @ 12" D.C. fastener spacing. -156.5 psf @ 6" D.C. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. FL11651 R3 11 FL11651 14 R3 Metal Roof Panel D t 1 skmed.Ddf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 14 R3 265 C Im 1 4 15 32Plvwood NonHVHZ-signed odf Created by Independent Third Party: Yes 11651.15 26 Ga. Gulf Lek Min 26 Ga. Gulf Lek 16" Wide Roof Panel over 15/3Z" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-361.OPSF Other: -63.5 psf @ 5 3/16' D.C. fastener spacing.-121.75 psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16' D.C. fastener spacing. Install per manufacturers details. For use In HVHZ Zones. FL11651 R3 It FL11651 15 R3 Metal Roof Panel D t II - sioned.sdf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 15 R3 26Cuifl-k 16 15- 32Plvwood HVHZ-sioned odf Created by Independent Third Party: Yes 11651.16 26 Ga. Gulf Lek Min 26 Ga. Gulf Lek 16' Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R3 11 FL11651 16 R3 Metal Roof Panel DeL& Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5PSF Other: -63.5 psf @ 5 3/16' ox. fastener spacing.-121.75 psF @ 5 3/16' fastener spacing. -161 psf @ 5 3/16" fastener spacing. Install per manufacturers details. Not for use In HVHZ Zones. sianed.ndF Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FU 1651 R3 AE FL11651 16 R3 76CUIrL k 16 15- 32Plvwood NonHVHZ-signed.sdf 1 Created by Independent Third Party: Yes 11651.17 26 Ga. GuIFPBR Min 26 Ga. Gulf PBR Roof Panel over 15/32' Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant'. N/A Design Pressure: +N/A/-154.7PSF Other: -59.25 psf @ 24" D.C. fastener pattern.-154.75 psf @ 12" D.C. fastener pattern. Install per manufacturer details. Not for use in HVHZ F111651 R3 II FL11651 17 R3 Metal Roof Panel DgL4L sianed.odF Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 17 R3 26GuIFPBR 15- 32Plvwood NonHVHZ-sioned odf Created by Independent Third Party: Yes 11651.18 26 Ga. GUIfPBR Min 26 Ga. GulfPBR Roof Panel over Ix4 Wood Pudins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R3 IT FL11651 18 R3 Metal Roof Panel Detail- Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7PSF Other: -100.5 psf @ 24" D.C. fastener spacing.-151.75 psf @ 12' fastener spacing. Install per manufacturers details. For use in HVHZ Zones sioned.ndf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 IS R3 26GUIFPBR 1 4 15- 32PIywood HVHZ-Sig ed Ddf Created by Independent Third Party: Yes https://floridabuilding.org/Pr/pr_app_dtl.aspx?param=wGEVXQWtDgsQFc5KD/`2frrZeCS... 3/20/2018 Florida Building Code Online Page 5 of 5 11651.19 126 Ga. GuIfPBR Min 26 Ga. GuIfPBR over 15/32" Plywood Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design_ Pressure:+N/A/-154.7PSF Other: -60.5 psf @ 24" o.c. Fastener spacing.-154.75 psf @ 12" o.c. fastener spacing. Install per manufacturer's details. For use In HVHZ Zones. Installation Instructions FL11651 R3 11 FL11651 19 R3 Metal Roof Panel Det '1- slaned.odF Verified By: Dan Kuhn, P.E. 75519 CreatedbyIndependent Third Party: Yes Evaluation Reports FLI1651 R3 AE FL11651 19 R3 26G IFPBR 15- 32Plvwood HVHZ-signed,DdF Created by Independent Third Parry: Yes 11651.20 26 Ga. GUVPBR Min 26 Ga. GuIfPBR over 10 Wood Purlins over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7PSF Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75 psf @ 12" fastener spacing. Install per manufacturer's details. Not for use in HVHZ Zones Installation Instructions FL11651 R3 II FL11651 20 R3 Metal Roof Panel Detail - signetl odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports FL11651 R3 AE FL11651 20 R3 26GuIFPBR 1 4 IS - 32Plvwood NonHVHZ-staned.odf Created by Independent Third Party: Yes Go to Page u tip Back Wert 00Page l/200 $gntapL Inc :: 2fiel Blair to d, Tlifthalaau R 323n Phone: 8504e2-I824 The State of Florida is an A41M employer. Cpoyddht 2007-2013 Stateof Ronda:: Edvacvstatement:: Ameaslb0ity Statement:: Refund statement Under Florida low, email addresses are public mmrds. If you do not want your a -mall address released in response to a publlCme,vos request, do not send electronic mall to this antler. Instead, contact Me office by phone or by traditional mall. If you have any questions, please cented 850.487.1395. •Pursuant to section 455.275F3J. Florida statutes, effective October 1, 2012, licensees Seamed under chapter 455, F.S. must provide Me Department with an email address it they have one. The mays provided may be used for oRtlal communimelon with Me romea. However mall addresses are public record. If you do not wish to Supply a personal address, Please provide Me Department with an email address whIsh can be made available M Me publk. To determine if you am a licensee under Chapter 455, F.S., please elicit here . product Approval Accepts: FW •e r SCCUrl1}'AIETIIICS' https://floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5KVo2frrZeCS... 3/20/2018